Hammer tapping test Principle of the test

When tapping test surface with a light hammer, near surface delaminated area will show hollow sounding comparing with that of the sound area. Therefore, hammer tapping survey could identify near surface defects.

Application
Identify position of near surface defects, such as delaminated area.

Identify position of delamination between two layers of materials, e.g. tile/ concrete, rendering/ substrate, etc.

Equipment
A light hammer or Automatic hammer tapping void detector consists of an electrical operated stainless steel ball creating tapping motion, a microphone for collecting responding sound after tapping and a colour lamp signal (green, orange and red) showing the test result. Green means no debonding, red means debonding, orange means doubtful.

Equipment

Test procedures
Tapping the test surface with a light hammer or the void detector.

Mark the suspended immediately.

area

with

chalk

or

crayon

Measure the size of the suspended area and record to worksheet.

Reporting
Method of testing, e.g. by a light hammer or automatic hammer tapping void detector.

Type of surface being tested, e.g. concrete or tile surface.


Size and position of suspected areas.

Advantages
Non-destructive test. Quick and simple.

Limitations - Traditional hammer


Need access to getting direct contact with the test surface. Require well-trained and experienced technicians for performing the test. Test results is subjective. It may vary against different technicians.

Limitations - Automatic void detector


Need access to getting direct contact with the test surface. The equipment must be firmly contacted with test surface because it shows green lamp when the steel ball is not hitting to test surface.