A F S 6 7 5 - E R G T T T S U D A E E E E E E N Z Z X 0 5 . 0 1
Basic Options 670: FE Version 675: GbE Version 677: 16 x Ports GbE Version Power over Ethernet Option (PoE) P: PoE (Slot 1 & 2 need to be of T Type; PS need to be of H / Z type) E: No PoE Mounting Option R: Ports on rear side E: Ports on front side Gigabit Ethernet (GbE) Option CP: 2 x GbE Combo Ports GP: 4 x GbE SFP cages GT: 4 x 10/100/1000 BaseT Ports GS: 2 x GbE SFP cages & 2 10/100/1000 BaseT Ports EE: No GbE Ports (AFS670/677) Management Ports Electrical Port Options 10/100 BaseT Optical Port Options SC connector SFP cage
1KHA - 001 138 - SEN - 01.10 - Printed in Switzerland ABB Switzerland Ltd, January 2010. The right to modifications or deviations due to technical progress is reserved.

Port Options T: 2 x Ports 10/100BaseT D: 2 x Ports FE SC, MM (8 dB) F: 2 x Ports FE SC, SM (16 dB) I: 2 x Ports FE SC, SM, Long haul (7-29 dB) K: 2 x Ports FE SC, SM, extra Long haul (14-47 dB) A: 2 x Ports FE ST, MM (8 dB) B: 2 x Ports FE ST, SM (16 dB) S: 2 x SFP cages U: 2 x Ports FE MTRJ, MM (8 dB) V: 2 x Ports FL ST, MM (9.5 dB) M: 2 x Ports FE M12 connector E: Slot empty

Temperature Options N: Temperature range 0C 60C P: Temperature range -40C 85C Z: Temperature range -40C 85C incl. Conformal coating Power Supply Options L: Low voltage PS (9,660VDC), spring clamps H: High Voltage PS (77320VDC, 90265VAC), spring clamps Y: Low Voltage PS (9,660VDC), connector Z: High Voltage PS (77320VDC, 90265VAC), connector E: No redundant PS

Future Option X: Default

Firmware Option Firmware release

M12 connector Ports on front side

ST connector

MTRJ connector

Ports on rear side

USB Port for CRA (Configuration Recovery Adapter) V.24 Port for Management 2 x Alarm Switchover Contacts (230VAC, 2A)

Available SFPs Normal Temperature Range FAST SFP-MM LC: FAST SFP-SM LC: FAST SFP-LH LC: FAST SFP-SM+ LC: SFP-SX LC: SFP-LX LC: SFP-LH LC: SFP-LH+ LC: 0C 60C FE, MM, 1310nm, FE, SM, 1310nm, FE, SM, 1550nm, FE, SM, 1310nm, GbE, GbE, GbE, GbE, 0-8dB 0-13dB 10-29dB 10-29dB

Utility grade Switch IEC61850 approved IEEE1613 approved EMC/ EMI EN61000-4-2 (ESD): EN61000-4-3: EN61000-4-4 (Burst): EN61000-4-5 (Surge): EN61000-4-12: EN61000-4-16: IEEE C37.90 IEEE C37.90.1 IEEE C37.90.2 IEEE C37.90.3 8kV contact discharge,15kV air discharge 35Vpp/m (802700 MHz); 1kHz, 80% AM 4kV power line, 4kV signal- und data line power line: 2kV (line/earth),1kV (line/ line) 2,5kV line/earth,1kV line/line (1MHz) 30V; 50Hz continous; 300V, 50Hz 1s HV impulse 5 kV line/earth Burst 4 kV, damped vibr. 2.5 kV line/earth, 1 kV line/line Electromagnetic field 80 - 1000 MHz 35 v/m (peak) ESD; contact discharge 8 kV; air discharge 15 kV

Applicable Standards IEEE802.1d IEEE802.1D/p IEEE802.1D IEEE802.1Q-1998 IEEE802.1x IEEE802.1AB IEEE802.3 2002 IEEE802.3ac IEEE802.3ad IEEE802.3af IEEE1588 Radius RMON SNMP V1/V2/V3 SNTP MAC Bridges Port Priority Switching, GARP, GMRP, Spanning Tree (Supported via 802.1S implementation) Virtual Bridged Local Area Networks (VLAN Tagging, Port Based VLANs, GVRP) Port Authentication Topology Discovery (LLDP) Ethernet VLAN Tagging Link Aggregation Power over Ethernet (PoE) Precision Time Protocol (PTP) Centralized Password Management Remote Monitoring Simple Network Management Protocol Simple Network Time Protocol

Protection Features IEEE802.1w IEC62439 E-MRP Rapid Spanning Tree Protocol (RSTP) Media Redundancy Protocol (MRP) Enhanced MRP

MM, 850nm, 0-7.5dB MM, 1310nm, 0-11dB SM, 1550nm, 6-22dB SM, 1550nm, 13-32dB 10-29dB 0-8dB 0-13dB 10-29dB

E-MRP Performance: Ring with < 10 Devices: Switch over time < 10ms Ring with < 100 Devices: Switch over time < 40ms Redundant coupling of several E-MRP rings is supported. Network topology consisting of a main ring and subrings is also supported (up to 4 subring ports per device). Each device supports multiple protection protocols (e.g. E-MRP on port 1 & 2, MRP on port 3 & 4). For more details please refer to the AFS user manual.

Extended Temperature Range -40C 85C FAST SFP-LH LC EEC: FE, SM, 1550nm, FAST SFP-MM LC EEC: FE, MM, 1310nm, FAST SFP-SM LC EEC: FE, SM, 1310nm, FAST SFP-SM+ LC EEC: FE, SM, 1310nm, SFP-LH LC-EEC: SFP-LX LC EEC: SFP-SX LC EEC:

GbE, SM, 1550nm, 6-22dB GbE, MM, 1310nm, 0-11dB GbE, MM, 850nm, 0-7.5dB

Mechanical Tests IEC60068-2-27 Shock: 15g,11ms duration,18 Shocks IEC60068-2-6 Vibration: 1mm, (213,2Hz), 90min.; 0,7g, (13,2100Hz), 90min.; 3,5 mm, (39Hz),10 cycles, 1 octave/ min.; 1g, (9150Hz),10 cycles,1 octave/min.

www.abb.com/utilitycommunications

ABB FOX Switch (AFS) Family for utility applications AFS650 / AFS655 Overview

For ABB internal use only!

Customer Benefits Utility Grade Products, specially designed for substation environment Applications Substation Automation Establish a Fast Ethernet or Gigabit Ethernet Backbone to provide communication for IEC61850 Substation Automation applications such as: GOOSE messages Sampled Values (SV) Client Server communication Distribution Communication Establish a Wide Area Network based on Fast Ethernet or Gigabit Ethernet to provide communication for Distribution SCADA System applications such as: IEC60870-5-104 data communication Operational telephony system Metering In Plant Communication Establish a Local Area Network based on Fast Ethernet or Gigabit Ethernet to provide communication for In Plant applications such as: CCTV system Public Announcement System In Plant telephony system High EMC EMI Immunity Extended temperature range Redundant power supply available for DIN rail & 19 AC/ DC power supply Wide input range of power supply PoE as an option Enhanced protection schemes for traffic protection

Very high system availability because of: High MTBF of the equipment itself Fan-less design Very fast switchover time in case of link disturbance Scalable port density from 8 to 28 Ports, including GbE functionality Overall ABB Communication Solution Part of ABB Communication Solution Family Part of ABB Substation Solution System integration covering all aspects and applications such as SCADA data traffic, IEC61850 or operational telephony. Specially for packet switched solutions design and system integration plays a key role for network performance and availability. Based on more than 60 years if experience, a broad solution portfolio and intensive application and system testing, ABB offers solutions designed according to utility requirements providing highest system availability.

A F S 6 5 5 - 6 2 C E C T N H H X 0 5 . 0 1
Basic Options 650: FE Version 655: GbE Version Port Amount 6: 7: 8: 9: 6 7 8 9 x x x x 10/100 10/100 10/100 10/100 BaseT BaseT BaseT BaseT Ports (only AFS655) Ports (only AFS655) Ports Ports (only AFS650) Firmware Option Firmware release Future Option X: Default Power Supply Options (only connector) LL: Redundant Low Voltage PS (18VDC - 60VDC) HH: Redundant High Voltage PS (48VDC - 320VDC or 90VAC - 265VAC) HE: Single High Voltage PS, spring clamps AFS650-9 2D: 2 x Ports FE SC, Multimode 2F: 2 x Ports FE SC, Singlemode 2I: 2 x Ports FE SC, Singlemode, Long Haul 2K: 2 x Ports FE SC, Singlemode, extra Long Haul 2A: 2 x Ports FE ST, Multimode 2B: 2 x Ports FE ST, Singlemode 2U: 2 x Ports FE MTRJ, Multimode Management Ports
1KHA - 001 138 - SEN - 02.10 - Printed in Switzerland ABB Switzerland Ltd, February 2010. The right to modifications or deviations due to technical progress is reserved.

Uplink 1 Option AFS650 AFS650-8 ED: 1 x Port FE SC, Multimode EF: 1 x Port FE SC, Singlemode EI: 1 x Port FE SC, Singlemode, Long Haul EK: 1 x Port FE SC, Singlemode, extra Long Haull EA: 1 x Port FE ST, Multimode EB: 1 x Port FE ST, Singlemode EU: 1 x Port FE MTRJ, Multimode AFS655 AFS655-6 AFS655-7 AFS655-8 2C: 2 x GbE Combo Ports 2G: 2 x GbE SFP cage Uplink 2 Option AFS650 AFS650-8 AFS650-9 ED: 1 x Port FE SC, Multimode EF: 1 x Port FE SC, Singlemode EI: 1 x Port FE SC, Singlemode, Long Haul EK: 1 x Port FE SC, Singlemode, extra Long Haul EA: 1 x Port FE ST, Multimode EB: 1 x Port FE ST, Singlemode EU: 1 x Port FE MTRJ, Multimode AFS655 AFS655-6 AFS655-7 AFS655-8 2S: 2 x FE SFP cage EC: 1 x GbE Combo Ports EG: 1 x GbE SFP cage

USB Port for CRA (Configuration Recovery Adapter) V.24 Port for Management 2 x Alarm Switchover Contacts (230VAC, 2A)

Temperature Options N: Temperature range 0C 60C P: Temperature range -40C 85C Z: Temperature range -40C 85C incl. Conformal coating Additional Port Option T: 6 x 10/100BaseT S: 6 x FE SFP cage (AFS655 only) Glossary Combo Port E-MRP GbE MM MRP PoE RSTP SM VLAN SFP cage & electrical port Enhanced MRP Gigabit Ethernet (1000Mbps) Multimode Media Redundancy Protocol Power over Ethernet Raid Spanning Tree Protocol Singlemode Virtual LAN

www.abb.com/utilitycommunications