Tiempo de bombeo para llenar el tanque:

Tb= Volumen del tanque / Q = 4583,397.6 Gal/ 2,000 =2,291.7min


Tb= 2,971min x (1hr/60min) x (1dia / 24 hrs) = 2 dias

Configuracin del tanque (considerando un dimetro de 200)


Diametro
A=(3.1416) x d2 / 4 = (3.1416) x 2002 / 4
A=31,415.92ft2
H= Volumen del tanque / A
= 612,754ft3 / 31,451.92ft2
Altura

H=19.50ft

Clculos de costo
- Calculo de la potencia.
P= Ha x Q x GS/ 3956 = (50)(2,000)(1) / 3,956
P= 25.27 HP

Eficiencia (70%=0.7)
BHP (Break Horse Power)
BHP= P/n = 25.27HP/ .7 = 36.1HP

Transformacion a Watts
36.1 HP (1KW/1.34)= 26.9 KW

Obtencion de Kw/Hr
26.9Kw(12hr)= 322 Kw/Hr

Costo de operacin.
1 Kw/Hr= $1.10
322 Kw/hr ($1.10pesos/(Kw/Hr))= $354 Pesos/dia
$354 x 365dias 129,210 pesos/ao

Costo de Mantenimiento (30%)


$129,210 x (.30)= $38,763 Pesos/ao

Costo Total.
$129,210 + $38,763 = $167,973 pesos /ao /bomba.
$167,973 x 3 bombas = $503, 919 pesos/ ao

TOTAL= $503,919 MXP/Ao