You are on page 1of 43

RAD International Technical Seminar

Abis & Ater Optimization

Presented by:
CBNetworks
Technical Support
support.technique@cbnetworks.fr
http://www.cbnetworks.fr

May 2007

Agenda
Background
Vmux-400/420 features
How does it work?
Vmux-4.xx Configurator Tool
Statistics

Interoperability
Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 2

Optimization Market Needs


Market potential:
1 Billion potential cellular subscribers in GSM rural areas (Nokia
Chairman)
Cellular backhaul relies on leased lines, private networks and
satellite connections
Backhaul costs reach 40-60% of the operators OpEx
2.5G / 3G services and mobile users increase incurs additional
network investments (optimized 2G leased lines can be transferred
to 3G networks)

Connectivity optimization reduces costs

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 3

GSM Network Architecture


Interface:
Solution:

E(PCM)
Vmux-2100/
Gmux-2000

A(PCM) / Ater*
Vmux-2100 / 420*

Abis
Vmux-400/420

BSC
BTS

BTS

PSTN
MSC

BSC

BTS

BTS

BTS

MSC

BSC
BTS

HLR

BTS

BTS

VLR

*Depends on the GSM Transcoder location:

BTS

- if located at MSC Ater (Vmux-420)


- if located at BSC A Interface (Vmux-2100/Gmux-2000)

BTS Base Transceiver Station

BSC Base Station Controller

MSC Mobile Switching Centre

HLR & VLR Home & Visitor Location Registers

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

(= BSS)

Abis & Ater Gateway TS-2007 Slide 4

Optimization and not Compression


BSC

Ater

Abis

Optimized data
BTS

ABIS/ ATER contains:


1. Compressed voice
2. Idle channels
3. Silence within active calls
4. Signaling + headers [ = overhead]
5. Data (such as GPRS / EDGE)
http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 5

Agenda
Background
Vmux-400/420 features
How does it work?
Vmux-4.xx Configurator Tool
Statistics

Interoperability
Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 6

Vmux-400 Features
Average Optimization: Up to 3:1 (fractional uplink)
User Input: 1 or 2xE1/T1 (ordering option)
Uplink Interfaces: E1/T1, ETH/IP, Serial (all built-in)
Clocking: Clock is transferred even when using ETH/IP
uplink
Power Options: AC/DC

Data compression: (NEW)


Compresses ~ 10% - 15% more
during peak hours (License is needed)
Point to Multipoint (using bundles)

Voice CODECs
Interoperability with all Major vendors
Tools, such as Bandwidth Calculator, Configurator
http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 7

Vmux-420 (Beta) Features


All Vmux-400 features (except Serial Uplink & T1)
User Input: Up to 12xE1 (4, 8, or 12 - ordering option)
Uplink Interfaces: Up to 6xE1 or ETH/IP (all built-in)
Chassis: 1U, 19 wide
Redundancy: full redundancy (Carrier Class Product)
Dry Contact Alarm Relay

TDM trunks aggregation (grooming)


Interoperability between Vmux-400 and Vmux-420

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 8

Vmux-420 Back Panel

2 Fully redundant Main Modules, in case of H.W


malfunction
All ports connected to both Main Modules, supplying FULL
redundancy

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 9

Vmux-400/420 Management
User terminal
Telnet
RV-LITE + SNMP traps

ConfiguRAD

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 10

Agenda
Background
Vmux-400/420 features
How does it work?
Vmux-4.xx Configurator Tool

Statistics
Interoperability
Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 11

Operation
Optimization process
1.

Suppress Idle channels

2.

Suppress traffic when there are Silence frames within active calls*

3.

Remove Signaling HDLC flags (only valid signaling is transferred)


Suppress signaling FISU & LSSU (ATER segment only)

Vmux-400/420
Vmux-400/420

FROM
BSC

Optimized Data

(MSC)

ABIS (/ ATER)
Compressed Voice

BTS (/BSC)
Optimization

(* when DTX mode is active in the GSM network)


http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 12

Data Compression

How does it works?

- The data compression unit accumulates information coming from the optimization unit and
compresses it. The information is compressed similar to Zip a file in PC

Performance
- Saves about 10 - 15% bandwidth during peak hours.
- Higher performance when there is more Data traffic (GPRS / EDGE - up to 50%)
- There are 2 compression levels: Normal level and High level.

Why Data?
- The output from the optimization unit contains data and not voice
- This is non-destructive compression.

Tradeoff for High Packet loss level


- Sensitive to packet loss therefore it is only good for networks with low packet loss.

License dependant
Vmux-400/420
Vmux-400/420

Optimized + Compressed Data

ABIS / ATER
Compressed Voice

BTS
Optimization

Data
Compression

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 13

Traffic Types Supported VOICE


Voice Codecs:
FR (Full Rate)

EFR (Enhanced Full Rate)


AMR (Adaptive Multi-Rate)
HR (Half Rate)

AMR-HR

Up to 24 timeslots
Per Vmux-400 *

Vmux-400/420 can automatically


detect the GSM sub-channel rate
(16kbps or 8kbps)

* Current H.W. limitation (there is no limitation for the Vmux-420)


http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 14

Traffic Types Supported DATA


SMS / WAP:
Transferred as part of the signaling
channel.

GPRS:
CS* 1,2,3 and 4 transported over timeslots
configured for TRAU traffic => BTS can use
any TRAU timeslot to transmit GPRS

EDGE:
Transported over timeslots configured for
TRANSPARENT.
BTS must use a predefined set of
timeslots for EDGE services

*CS = Code Scheme


http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 15

Clocking over TDM/IP Link


RCV (Ingress)

RCV (Uplink)
Vmux-400

TDM\IP
Network

Vmux-400/420

ADAPTIVE = ENABLE

ADAPTIVE = ENABLE

For IP uplink

For IP uplink

BTS

BSC

(LBT)

(Clk Source)

Clock transferred from BSC to BTS over any transmission


network (Adaptive clock recovery mechanism enables to transfer
the clock over ETH/IP unique feature!)

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 16

Clocking over Satellite IP Link


RCV (Ingress)

Internal
Vmux-400/OCXO
ADAPTIVE = DISABLE

Vmux-400/420

IP network

ADAPTIVE = DISABLE

BTS

BSC

(LBT)

(Clk Source)

OCXO* (ordering option) for highly accurate internal oscillator


operating at 2.048Mhz 0.5 ppm (use when IP network jitter is
higher than 50 msec)

* Only needed on the BTS side


http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 17

Signaling Rate Detection

Signaling Rate Detection

Vmux-400/420 can automatically detect the data rate of the signaling channels (16,
32 or 64Kbps)

Before Vmux- 400/420 detects

After Vmux- 400/420 detects

signaling channels rate


Ts#

|
v

1
2
3
4
5
6
7
8
9
10

Type

Dynamic
Dynamic
Dynamic
Dynamic
Dynamic
Dynamic
Dynamic
Dynamic
Dynamic
Dynamic

signaling channels rate

Byte
Reversal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Bundle#

1
1
1
1
1
1
1
1
1
1

Ts#

|
v

1
2
3
4
5
6
7
8
9
10

Type

Sig64
Sig64
Sig64
Dynamic
Dynamic
Dynamic
Dynamic
Dynamic
Dynamic
Dynamic

Byte
Reversal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Bundle#

1
1
1
1
1
1
1
1
1
1

Available Time Slot Types:


All set to Dynamic

TRAU: GSM Speech


Sig64/Sig32/Sig16: HDLC Signaling, 64/32/16 kbps
Trp64/Trp32/Trp16: Transparent data, 64/32/16 kbps

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 18

Timeslot Type Detection (Ericsson)

Timeslot Type Detection (Ericsson)

After reboot, the Ericsson BSS changes timeslot assignment for speech and signaling. To
support this Vmux-400/420 can automatically detect the timeslot type (speech or signaling).

Before Vmux-400/420 detects timeslots type


Ts#

|
v

1
2
3
4
5
6
7
8
9
10

Type

Dynamic
Dynamic
Dynamic
Dynamic
Dynamic
Dynamic
Dynamic
Dynamic
Dynamic
Dynamic

Byte
Reversal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Bundle#

1
1
1
1
1
1
1
1
1
1

After Vmux-400/420 detects timeslots type


Ts#

|
v

1
2
3
4
5
6
7
8
9
10

Type

Sig64
Sig64
Sig64
TRAU
TRAU
TRAU
TRAU
TRAU
Dynamic
Dynamic

Byte
Reversal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Bundle#

1
1
1
1
1
1
1
1
1
1

Available Time Slot Types:


All set to Dynamic

TRAU: GSM Speech


Sig64/Sig32/Sig16: HDLC Signaling, 64/32/16 kbps
Trp64/Trp32/Trp16: Transparent data, 64/32/16 kbps

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 19

Agenda
Background
Vmux-400/420 features
How does it work?
Vmux-4.xx Configurator Tool
Statistics

Interoperability
Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 20

Vmux-4.xx Configurator Tool:


Step 1
1. Site survey
Collecting information from the
mobile operator:

1.

Site survey

2.

Configuration

3.

Bandwidth estimation
Configuration Tool

- GSM segment: ATER/ ABIS


- Vendor
- Uplink type: TDM / IP
- Timeslot assignment
- Downstream DTX (y/n)
- Clock transfer

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 21

Vmux-4.xx Configurator Tool:


Step 2
2. Configuration parameters
Configure device according to
the information we got from
the survey.

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

1.

Site survey

2.

Configuration

3.

Bandwidth estimation
Configuration Tool

Abis & Ater Gateway TS-2007 Slide 22

EXAMPLE:
Alcatel Time Slot Configuration
BSC/BTS Configuration:
(6 x TRX, 48 GSM speech channels)

1.

Site survey

2.

Configuration

3.

Bandwidth estimation
Configuration Tool

Vmux-400 Time Slot Table:


Display Time Slots Configuration
Ts#
1
2
| 3
v 4
5
6
7
8
9
10

Type
-Sig64
TRAU
TRAU
Sig16
TRAU
TRAU
TRAU
TRAU
TRAU

Byte Reversal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Bundle#
1
1
1
1
1
1
1
1
1
1

Available Time Slot Types:


TRAU: GSM Speech
Sig64/Sig32/Sig16: HDLC Signaling, 64/32/16 kbps

Trp64/Trp32/Trp16: Transparent data, 64/32/16 kbps


http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 23

Vmux-4.xx Configurator Tool:


Step 3
3. Bandwidth considerations
Bandwidth is influenced by the
following parameters:

1.

Site survey

2.

Configuration

3.

Bandwidth estimation
Configuration Tool

Fixed
- Timeslot assignment
- Uplink type (IP or TDM)
- Using Downstream DTX.
Estimated
- Estimated silence within calls
- Estimated idle channels

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 24

Vmux-4.xx Configurator Tool:


Vmux-400/420 Configuration tool

1.

Site survey

2.

Configuration

3.

Bandwidth estimation
Configuration Tool

Vmux-400 Configuration guide

Try it in workshop

Available at: http://www.cbnetworks.fr/ftp/rad/outils/ InfoCenter Technical Resources


http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 25

Agenda
Background
Vmux-400/420 features
How does it work?
Vmux-4.xx Configurator Tool
Statistics

Interoperability
Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 26

Statistics
Uplink statistics: TDM/Serial/Ethernet uplink:
Evaluate bandwidth on uplink
Signaling statistics:
Verify signaling channels are up
TRAU statistics:
TRAU traffic analyzing
Bandwidth control statistics:
Display calls stopped or discarded
BW utilization statistics:
Display enhanced information

on bandwidth consumption

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 27

Agenda
Background
Vmux-400/420 features
How does it work?

Vmux-4.xx Configurator Tool


Statistics
Interoperability
Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 28

Vmux-400 Interoperability
Interoperable with all major vendors:

Ericsson, Siemens, Nokia, AlcatelLucent, Huawei, Motorola, Nortel,

Vmux-400/420

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 29

Agenda
Background
Vmux-400/420 features
How does it work?

Vmux-4.xx Configurator Tool


Statistics
Interoperability
Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 30

GSM Service to Remote / Rural


Regions
Remote Site

Central Office

ETH/ Vmux-400
IP
E1

MSC

ETH/IP

BSC
E1s

BTS

Vmux-400
E1

Hub
Transceivers

Remote Site

E1

Vmux-400

Central site
solution is needed

ETH/ Vmux-400
IP
E1

BTS

Connection via satellite, microwave, terrestrial links, flexible


interfacing (IP/ETH/SERIAL/E1)
Effective solution where the cellular operator pays for expensive
transmission links
http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 31

GSM Service to Remote / Rural


Regions
Remote Site

Central Office

ETH/ Vmux-400
IP
E1

MSC

BSC

BTS

Vmux-420

E1s

Hub
Transceivers
Up to 12 E1

Remote Site

ETH/IP

ETH/ Vmux-400
IP
E1

BTS

Connection via satellite, microwave, terrestrial links, flexible


interfacing (IP/ETH/SERIAL/E1)
Effective solution where the cellular operator pays for expensive
transmission links
http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 32

Summary

RAD offers a full MSC-BSC-BTS cellular backhaul solution

Cost effective voice optimization solution for central and


remote sites
Up to 3:1 optimization of Abis/ Ater interface

Up to 10% - 15% saving with Data Compression


Connects over any uplink
Interoperable with all major vendors

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 33

thank you
for your attention
Technical Support
support.technique@cbnetworks.fr
http://www.cbnetworks.fr
http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 34

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 35

Vmux-400 Ports

Control Port
E1 Uplink
(Egress/Output)
to network

Serial Uplink
(Egress/Output)
to network

User E1 Ports*
(Ingress/Input)
from BTS/BSC/MSC

ETH Management

ETH/IP Uplink
(Egress/Output)
to network

* Ordering Options: 1 or 2 ingress E1 ports


http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 36

Vmux-420 Ports

Up to 12 User E1
Ports*
(Ingress/Input)
from
BTS/BSC/MSC

* Ordering Options:

Up to 6 E1 Uplink
(Egress/Output)
to network
ETH/IP Uplink
(Egress/Output)
to network

Control
Port
ETH
Management
port

2 Redundant
Power
supplies

Alarm
Relay

- 4,8 or 12 Ingress E1 ports


- 2,4 or 6 Egress E1 ports

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 37

GSM Subchannel Rate Detection


GSM Subchannel Rate Detection
Full Rate (FR): Each voice
channel is carried in a 16 kbps
sub channel
Half Rate (HR): Each voice
channel is carried in a 8 kbps sub
channel
Vmux-400/420 can automatically
detect the GSM subchannel rate
(16 kbps or 8 kbps)

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 38

Ericsson Time Slot Configuration


BSC/BTS Configuration:
(10.5 x TRX, 84 GSM speech channels)
CH
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31

Sub Channel

MPLEX16
MPLEX16
MPLEX16

MPLEX16
MPLEX16
MPLEX16
MPLEX16
MPLEX16
MPLEX16
MPLEX16
MPLEX16
MPLEX16
MPLEX16

MPLEX16

MPLEX16
MPLEX16

CONC
MPLEX16 MPLEX16
MPLEX16 MPLEX16
UNDEF
MPLEX16 MPLEX16
UNDEF
UNDEF
UNDEF
UNDEF
UNDEF
MPLEX16 MPLEX16
MPLEX16 MPLEX16
MPLEX16 MPLEX16
MPLEX16 MPLEX16
MPLEX16 MPLEX16
MPLEX16 MPLEX16
MPLEX16 MPLEX16
MPLEX16 MPLEX16
MPLEX16 MPLEX16
MPLEX16 MPLEX16
CONC
UNDEF
UNDEF
MPLEX16 MPLEX16
UNDEF
UNDEF
UNDEF
UNDEF
MPLEX16 MPLEX16
CONC
MPLEX16 MPLEX16

Content

MPLEX16
MPLEX16
MPLEX16

MPLEX16
MPLEX16
MPLEX16
MPLEX16
MPLEX16
MPLEX16
MPLEX16
MPLEX16
MPLEX16
MPLEX16

MPLEX16

MPLEX16
MPLEX16

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

TRXC SIGNAL
SPEECH/DATA
SPEECH/DATA
IDLE
SPEECH/DATA
IDLE
IDLE
IDLE
IDLE
IDLE
SPEECH/DATA
SPEECH/DATA
SPEECH/DATA
SPEECH/DATA
SPEECH/DATA
SPEECH/DATA
SPEECH/DATA
SPEECH/DATA
SPEECH/DATA
SPEECH/DATA
TRXC SIGNAL
IDLE
IDLE
SPEECH/DATA
IDLE
IDLE
IDLE
IDLE
SPEECH/DATA
CF/TRXC SIGNAL
SPEECH/DATA

How to configure Vmux-4.xx according to


the timeslots table?
TS1, 21, 30

: Sig64

TS2, 3, 5, 11-20, 24, 29, 31 : TRAU

TS4, 6-10, 22-23, 25-28:

: N/C.

Available Time Slot Types:


TRAU: GSM Speech

Sig64/Sig32/Sig16: HDLC Signaling, 64/32/16 kbps


Trp64/Trp32/Trp16: Transparent data, 64/32/16 kbps

Abis & Ater Gateway TS-2007 Slide 39

Statistics: BW Utilization Statistics


Vmux400 / BSC

ALRM

Display Total Accumulated

Number of seconds
accumulated for each
bandwidth range

< 64

Kbps]

... (236024)

[704 -767

Kbps]

... (44)

[ 64 -127

Kbps]

... (5)

[768 -831

Kbps]

... (354)

[128 -191

Kbps]

... (314)

[832 -895

Kbps]

... (233)

[192 -255

Kbps]

... (1203)

[896 -959

Kbps]

... (23)

[256 -319

Kbps]

... (3455)

[960 -1023 Kbps]

... (4)

[320 -383

Kbps]

... (14563)

[1024-1087 Kbps]

... (0)

[384 -447

Kbps]

... (21003)

[1088-1151 Kbps]

... (0)

[448 -511

Kbps]

... (13900)

[1152-1215 Kbps]

... (4)

[512 -575

Kbps]

... (4231)

[1216-1279 Kbps]

... (0)

[576 -639

Kbps]

... (911)

[1280-1343 Kbps]

... (0)

[640 -703

Kbps]

... (43)

[1344-1407 Kbps]

... (0)

... (N)
>

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 40

Mobile Platforms

MSC

BSC

Vmux-400

E1s

Serial/
IP/E1

E1

Vmux-400
Serial/IP/E1
E1

BTS

Supply service to mobile platforms such as cruise ships

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 41

Mobile Platforms

MSC

BSC

Vmux-400

E1s

Serial/
IP/E1

E1

Vmux-400
Serial/IP/E1
E1

BTS

Supply service in large and crowded events using trucks

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 42

Terrestrial Daisy Chained BTSs

FE1

BTS
FE1

BTS
MSC

BSC
E1s

Vmux-400 / 420
E1

Vmux-400

TDM or IP

E1

BTS

E1

DXC

FE1

FE1
FE1

BTS
BTS
BTS

Requires Drop & Insert capability at the BTS


Suitable when each BTS serves a small area
http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 43

You might also like