COPPER, ALUMINIUM, LEAD, STEEL, PVC AND XLPE PRICE VARIATIONS FACTORS

FOR ELECTRIC CABLES

CONFORMING TO SPECIFICATIONS:
SANS 97
SANS 1507
SANS 1339
BS6346
SATS CSE 49E & G

THE VARIATIONS IN THIS BOOKLET ARE PER 100 METRES OF CABLE


FOR EACH R1,00, RISE OR FALL, PER METRIC TON IN
THE PRICES OF COPPER, ALUMINIUM, LEAD, STEEL, PVC AND XLPE.

ISSUED BY

THE ASSOCIATION OF ELECTRIC CABLE MANUFACTURERS OF SOUTH AFRICA

2007

JOHANNESBURG

INDEX
Page 1

1000V Low Tension General Purpose Cables to SANS 97 AFAA

Page 2

1000V Low Tension General Purpose Cables to SANS 97 AFAA

Page 3

3,3kV General Purpose Belted Cables to SANS 97 AFAA

Page 4

3,3kV General Purpose Belted Cables to SANS 97 AFAA

Page 5

6,6kV General Purpose Belted Fully impregnated Cables to SANS 97 Tables 9 & 15

Page 6

6,6kV General Purpose Belted Fully impregnated cables to SANS 97 Table 16

Page 7

6,6kV General Purpose Belted Drained Cables to SANS 97 AFAA

Page 8

6,6kV General Purpose Belted Drained Cables to SANS 97 AFAA

Page 9

11kV General Purpose Fully Impregnated Belted Cables to SANS 97 Tables 17 & 18

Page 10

11kV Screened Type Fully Impregnated General Purpose Cables to SANS 97 Tables 10 & 19.

Page 11

11kV Screened Type Fully Impregnated General Purpose Cables to SANS 97 AFAA

Page 12

11kV Drained General Purpose Belted Cables for Normal Service Conditions &
11kV Fully Impregnated Cables with Augmented Dielectric to SANS 97 AFAA

Page 13

11kV Screened Type Drained General Purpose Cable for Normal Service Conditions &
11kV Fully impregnated Cables with Augmented Dielectric to SANS 97 AFAA

Page 14

12,7/22kV General Purpose Impregnated Screened Cables to SANS 97 Tables 11 & 20

Page 15

1000V Low Tension Heavy Duty Cables to SANS 97 AFAA

Page 16

1000V Low Tension Heavy Duty Cables to SANS 97 AFAA

Page 17

3,3kV Heavy Duty (Belted) Cables to SANS 97 AFAA

Page 18

3,3kV Heavy Duty (Belted) Cables to SANS 97 Table 22.

Page 19

6,6kV Heavy Duty (Belted) Cables to SANS 97 Tables 13 & 23

Page 20

6,6kV Heavy Duty (Belted) Cables to SANS 97 Table 24

Page 21

11kV Heavy Duty (Belted) Cables to SANS 97 Tables 25 & 26

Page 22

11kV Heavy Duty Screened Cables to SANS 97 Tables 14 & 27

Page 23

11kV Heavy Duty Screened Cables to SANS 97 AFAA

Page 24

600/1000V PVC PVC SWA PVC Cables to SANS 1507

Page 25

600/1000V PVC PVC SWA PVC Cables to SANS 1507

Page 26

600/1000V PVC PVC SWA PVC Cables to SANS 1507

Page 27

600/1000V PVC PVC ECC/SWA PVC Cables to SANS 1507

Page 28

1,9/3,3kV 3 Core PVC PVC SWA PVC Cables to SANS 1507

Page 29

600/1000V Stranded AL PVC PVC SWA PVC Cables to SANS 1507

Page 30

600/1000V Solid AL PVC PVC SWA PVC Cables to SANS 1507

Page 31

600/1000V Solid AL PVC PVC SWA/ECC PVC Cables to SANS 1507

Page 32

600/1000V PVC PVCT ASA PVC or PVC PVC SWA PVC Cables to BS 6346

Page 33

600/1000V PVC PVCT ASA PVC Cables to BS 6346

Page 34

600/1000V 3 Core PVC PVC Cables with Split-Concentric Neutral &


Earth Conductors to SANS 1507

page 35

3,8/6,6kV single core type A Cable to SANS 1339

page 36

6,35/11kV single core type A cable to SANS 1339

page 37

8,7/15kV single core type A cable to SANS 1339 AFAA

page 38

12,7/22kV single core type A cable to SANS 1339

page 39

19/33kV single core type A cable to SANS 1339

Printed 2007/04/03

Index Page 1

INDEX
page 40

3,8/6,6kV single core type A2 cable to SANS 1339 AFAA

page 41
page 42

6,35/11kV single core type A2 cable to SANS 1339 AFAA


8,7/15kV single core type A2 cable to SANS 1339 AFAA

page 43

12,7/22kV single core type A2 cable to SANS 1339 AFAA

page 44

19/33kV single core type A2 cable to SANS 1339 AFAA

page 45

3,8/6,6kV single core type B cables to SANS 1339

page 46

6,35/11kV single core type B cable to SANS 1339

page 47

8,7/15kV single core type B cable to SANS 1339 AFAA

page 48

12,7/22kV single core type B cable to SANS 1339

page 49

19/33kV single core type B cable to SANS 1339

page 50

3,8/6,6kV three core type A cable to SANS 1339

page 51

6,35/11kV three core type A cable to SANS 1339

page 52

8,7/15kV three core type A cable to SANS 1339 AFAA

page 53

12,7/22kV three core type A cable to SANS 1339

page 54

19/33kV three core type A cable to SANS 1339

Page 55

3,8/6,6kV three-core type B cable to SANS 1339

Page 56

6,35/11kV three-core type B cable to SANS 1339

Page 57

8,7/15kV three-core type B cable to SANS 1339 AFAA

Page 58

12,7/22kV three-core type B cable to SANS 1339

Page 59

19/33kV three-core type B cable to SANS 1339

Page 60

Standard Signaling Cables (outdoor) to SATS Specification No.CSE 49E

Page 61

Standard Signaling Cables (indoor) to SATS Specification No.CSE 49G

Printed 2007/04/03

INDEX 2

PAGE 1

1000V LOW TENSION GENERAL PURPOSE CABLES TO SANS 97 AFAA


SINGLE CORE
2 CORE
RATED COPPER ALUMINIUM LEAD
RATED
PVC
COPPER ALUMINIUM LEAD
STEEL
PVC
AREA
AREA
DSTA SWA SERVING BEDDING
mm2
SERVING
OVER
&
mm2
ARMOUR SERVING
OVER
ARMOUR
COMBINED
6
0.011*
0.071 0.057 0.062
0.025
0.037
6
10
0.019
0.071 0.056 0.060
0.025
0.036
10
16
0.031
0.080 0.060 0.063
0.026
0.039
16
25
0.048
0.014
0.088 0.067 0.070
0.032
0.043
25
35
0.067
0.021
0.098 0.073 0.075
0.034
0.048
35
50
0.095
0.030
0.109 0.079 0.101
0.038
0.057
50
70
0.134
0.041
0.131 0.086 0.113
0.043
0.064
70
95
0.181
0.055
0.167 0.095 0.120
0.050
0.092
95
120
0.250
0.071
0.193 0.101 0.133
0.054
0.087
120
150
0.142
0.044
0.123
0.021
0.287
0.080
0.209 0.137 0.180
0.063
0.103
150
185
0.175
0.053
0.143
0.023
0.354
0.109
0.235 0.147 0.193
0.067
0.112
185
240
0.228
0.070
0.171
0.028
0.459
0.141
0.297 0.164 0.215
0.079
0.130
240
300
0.204
0.087
0.203
0.035
0.574
0.176
0.361 0.191 0.237
0.092
0.151
300
400
0.379
0.117
0.258
0.043
0.235
0.455 0.202 0.337
0.103
0.168
400
500
0.474
0.146
0.288
0.047
0.294
0.510 0.220 0.366
0.112
0.192
500
630
0.598
0.183
0.351
0.057
630
* Circular conductors

PAGE 1

Printed 2007/04/03

PAGE 2

1000V LOW TENSION GENERAL PURPOSE CABLES TO SANS 97 AFAA


3 CORE
RATED COPPER ALUMINIUM
AREA
mm2

6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

0.017*
0.029*
0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441
-

4 CORE

LEAD

STEEL
DSTA
SWA

0.076
0.087
0.100
0.100
0.119
0.143
0.170
0.203
0.235
0.265
0.309
0.381
0.450
0.581
0.679
-

0.059
0.066
0.070
0.072
0.078
0.086
0.094
0.129
0.140
0.152
0.163
0.192
0.201
0.233
0.253
-

0.066
0.072
0.098
0.084
0.107
0.117
0.128
0.180
0.194
0.200
0.223
0.295
0.351
0.390
0.481
-

PVC
COPPER ALUMINIUM
SERVING BEDDING
OVER
&
ARMOUR SERVING
COMBINED

0.026
0.032
0.035
0.035
0.038
0.043
0.051
0.060
0.066
0.076
0.083
0.097
0.105
0.110
0.127
-

0.039
0.043
0.051
0.051
0.058
0.065
0.083
0.101
0.110
0.122
0.140
0.156
0.179
0.201
0.217
-

0.023*
0.030*
0.062*
0.095
0.134
0.191
0.268
0.364
0.459
0.574
0.708
0.919
1.148
-

* Circular conductors

PAGE 2

Printed 2007/04/03

0.030
0.041
0.058
0.082
0.112
0.140
0.176
0.217
0.282
0.353
0.470
0.588
-

LEAD

STEEL
DSTA
SWA

0.084
0.096
0.119
0.122
0.145
0.172
0.209
0.257
0.297
0.360
0.437
0.529
0.630
0.752
0.907
-

0.064
0.070
0.077
0.082
0.087
0.096
0.133
0.149
0.160
0.174
0.189
0.212
0.234
0.269
0.292
-

0.069
0.077
0.106
0.109
0.119
0.130
0.183
0.202
0.215
0.238
0.327
0.370
0.440
0.513
0.627
-

RATED
PVC
SERVING BEDDING AREA
OVER
&
mm2
ARMOUR SERVING
COMBINED

0.027
0.033
0.038
0.041
0.046
0.053
0.063
0.071
0.079
0.091
0.099
0.111
0.122
0.134
0.145
-

0.042
0.047
0.058
0.059
0.072
0.084
0.103
0.119
0.130
0.049
0.161
0.189
0.209
0.230
0.249
-

6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 3

3,3kV GENERAL PURPOSE (BELTED) CABLES TO SANS 97 AFAA


1,9/3,3kV
SINGLE CORE
RATED COPPER ALUMINIUM
LEAD
AREA
mm2

16
25
35
50
70
95
120
150
185
240
300
400
500
630

0.142
0.175
0.228
0.284
0.379
0.474
0.598

0.044
0.053
0.070
0.087
0.117
0.146
0.183

0.141
0.150
0.179
0.213
0.257
0.299
0.360

PVC
SERVING
OVER
ARMOUR

0.023
0.027
0.029
0.037
0.044
0.047
0.058

COPPER ALUMINIUM

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441
-

* Circular conductors

PAGE 3

Printed 2007/04/03

LEAD

3 CORE
STEEL
DSTA
SWA

0.129
0.130
0.145
0.171
0.202
0.235
0.268
0.298
0.364
0.436
0.519
0.639
0.740
-

0.070
0.080
0.086
0.094
0.129
0.141
0.152
0.163
0.174
0.192
0.211
0.238
0.258
-

0.111
0.111
0.118
0.128
0.165
0.194
0.207
0.222
0.239
0.334
0.368
0.396
0.489
-

RATED
PVC
AREA
SERVING
BEDDING
OVER
&
mm2
ARMOUR
SERVING
COMBINED

0.041
0.041
0.044
0.051
0.059
0.066
0.076
0.080
0.091
0.100
0.111
0.120
0.130
-

0.061
0.061
0.072
0.082
0.100
0.110
0.121
0.137
0.149
0.163
0.189
0.205
0.222
-

16
25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 4

3,3kV GENERAL PURPOSE (BELTED) CABLES TO SANS 97 AFAA


3,3/3,3kV
SINGLE CORE
RATED COPPER ALUMINIUM
LEAD
AREA
mm2

16
25
35
50
70
95
120
150
185
240
300
400
500
630

0.142
0.175
0.228
0.284
0.379
0.474
0.598

0.044
0.053
0.070
0.087
0.117
0.146
0.183

0.149
0.170
0.197
0.225
0.278
0.303
0.360

PVC
SERVING
OVER
ARMOUR

0.026
0.028
0.035
0.038
0.045
0.049
0.059

COPPER ALUMINIUM

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441
-

* Circular conductors

PAGE 4

Printed 2007/04/03

LEAD

3 CORE
STEEL
DSTA
SWA

0.132
0.131
0.151
0.180
0.211
0.246
0.278
0.319
0.371
0.457
0.539
0.644
0.750
-

0.081
0.083
0.090
0.097
0.134
0.146
0.156
0.167
0.179
0.196
0.216
0.242
0.262
-

0.115
0.116
0.123
0.133
0.183
0.200
0.214
0.239
0.245
0.342
0.375
0.459
0.491
-

RATED
PVC
AREA
SERVING
BEDDING
OVER
&
mm2
ARMOUR
SERVING
COMBINED

0.043
0.043
0.045
0.053
0.063
0.067
0.077
0.088
0.093
0.102
0.112
0.123
0.131
-

0.064
0.064
0.077
0.085
0.103
0.113
0.124
0.143
0.152
0.167
0.192
0.209
0.225
-

16
25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 5

6,6kV GENERAL PURPOSE (BELTED) FULLY IMPREGNATED CABLES TO SANS 97 TABLES 9 & 15
3,8/6,6kV EARTHED
SINGLE CORE
RATED COPPER ALUMINIUM
LEAD
AREA
mm2

16
25
35
50
70
95
120
150
185
240
300
400
500
630

0.142
0.175
0.228
0.284
0.379
0.474
0.598

0.044
0.053
0.070
0.087
0.117
0.146
0.183

0.151
0.172
0.201
0.234
0.267
0.310
0.371

PVC
SERVING
OVER
ARMOUR

0.027
0.029
0.035
0.039
0.046
0.054
0.059

COPPER ALUMINIUM

0.066*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441
-

* Circular conductors

PAGE 5

Printed 2007/04/03

LEAD

3 CORE
STEEL
DSTA
SWA

0.151
0.150
0.172
0.194
0.233
0.261
0.310
0.361
0.382
0.464
0.554
0.663
0.781
-

0.086
0.088
0.094
0.101
0.139
0.152
0.162
0.173
0.185
0.202
0.221
0.248
0.269
-

0.118
0.120
0.128
0.137
0.192
0.208
0.222
0.237
0.296
0.350
0.384
0.472
0.508
-

RATED
PVC
AREA
SERVING
BEDDING
OVER
&
mm2
ARMOUR
SERVING
COMBINED

0.045
0.044
0.051
0.054
0.065
0.076
0.080
0.091
0.097
0.105
0.116
0.125
0.134
-

0.077
0.076
0.083
0.085
0.107
0.121
0.131
0.148
0.158
0.177
0.196
0.213
0.227
-

16
25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 6

6,6kV GENERAL PURPOSE (BELTED) FULLY IMPREGNATED CABLES TO SANS 97 TABLE 16


6,6/6,6kV UNEARTHED
SINGLE CORE
RATED COPPER ALUMINIUM
LEAD
AREA
mm2

16
25
35
50
70
95
120
150
185
240
300
400
500
630

0.142
0.175
0.228
0.284
0.379
0.474
0.598

0.044
0.053
0.070
0.087
0.117
0.146
0.183

0.171
0.194
0.224
0.252
0.299
0.348
0.380

PVC
SERVING
OVER
ARMOUR

0.028
0.030
0.037
0.044
0.048
0.057
0.066

COPPER ALUMINIUM

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441
-

* Circular conductors

PAGE 6

Printed 2007/04/03

LEAD

0.172
0.172
0.182
0.213
0.254
0.293
0.317
0.373
0.445
0.488
0.570
0.684
0.790
-

3 CORE TABLE 16
STEEL
DSTA
SWA

0.094
0.095
0.099
0.138
0.147
0.158
0.168
0.179
0.192
0.209
0.227
0.253
0.275
-

0.125
0.129
0.135
0.186
0.201
0.217
0.230
0.245
0.334
0.375
0.395
0.479
0.519
-

RATED
PVC
AREA
SERVING
BEDDING
OVER
&
mm2
ARMOUR
SERVING
COMBINED

0.051
0.051
0.054
0.063
0.070
0.078
0.088
0.093
0.100
0.109
0.118
0.128
0.137
-

0.083
0.082
0.086
0.103
0.118
0.126
0.144
0.153
0.163
0.186
0.202
0.217
0.234
-

16
25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 7

6,6kV GENERAL PURPOSE (BELTED) DRAINED CABLES TO SANS 97 AFAA


3,8/6,6kV EARTHED
SINGLE CORE
RATED COPPER ALUMINIUM
LEAD
AREA
mm2

16
25
35
50
70
95
120
150
185
240
300
400
500
630

0.142
0.175
0.228
0.284
0.379
0.474
0.598

0.044
0.053
0.070
0.087
0.117
0.146
0.183

0.168
0.181
0.209
0.257
0.287
0.353
0.382

PVC
SERVING
OVER
ARMOUR

0.028
0.030
0.036
0.043
0.047
0.056
0.065

COPPER ALUMINIUM

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441
-

*Circular conductors

PAGE 7

Printed 2007/04/03

LEAD

3 CORE
STEEL
DSTA
SWA

0.177
0.172
0.201
0.225
0.267
0.297
0.361
0.383
0.445
0.532
0.613
0.738
0.852
-

0.093
0.095
0.120
0.138
0.152
0.163
0.174
0.183
0.197
0.215
0.234
0.262
0.282
-

0.127
0.131
0.164
0.194
0.204
0.220
0.237
0.295
0.339
0.371
0.399
0.487
0.597
-

RATED
PVC
AREA
SERVING
BEDDING
OVER
&
mm2
ARMOUR
SERVING
COMBINED

0.053
0.051
0.056
0.064
0.071
0.079
0.090
0.096
0.101
0.111
0.120
0.130
0.139
-

0.084
0.083
0.097
0.106
0.119
0.130
0.147
0.155
0.165
0.189
0.205
0.222
0.237
-

16
25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 8

6,6kV GENERAL PURPOSE (BELTED) DRAINED CABLES TO SANS 97 AFAA.


6,6/6,6kV UNEARTHED
SINGLE CORE
RATED COPPER ALUMINIUM
LEAD
AREA
mm2

16
25
35
50
70
95
120
150
185
240
300
400
500
630

0.142
0.175
0.228
0.284
0.379
0.474
0.598

0.044
0.053
0.070
0.087
0.117
0.146
0.183

0.194
0.203
0.234
0.278
0.306
0.370
0.445

PVC
SERVING
OVER
ARMOUR

0.030
0.036
0.039
0.046
0.055
0.059
0.069

COPPER ALUMINIUM

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.532
0.211
0.264
0.353
0.441
-

*Circular conductors

PAGE 8

Printed 2007/04/03

LEAD

3 CORE
STEEL
DSTA
SWA

0.202
0.204
0.224
0.256
0.297
0.316
0.377
0.445
0.477
0.560
0.642
0.772
0.886
-

0.130
0.130
0.137
0.148
0.159
0.170
0.181
0.193
0.203
0.221
0.240
0.267
0.287
-

0.181
0.166
0.189
0.196
0.217
0.233
0.293
0.334
0.354
0.384
0.474
0.505
0.612
-

RATED
PVC
AREA
SERVING
BEDDING
OVER
&
mm2
ARMOUR
SERVING
COMBINED

0.086
0.085
0.091
0.100
0.110
0.126
0.133
0.141
0.151
0.165
0.179
0.191
0.205
-

0.101
0.100
0.105
0.118
0.126
0.145
0.154
0.164
0.179
0.195
0.212
0.228
0.245
-

16
25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 9

11kV GENERAL PURPOSE FULLY IMPREGNATED BELTED CABLES TO SANS 97 TABLES 17 & 18

RATED COPPER ALUMINIUM


AREA
mm2

16
25
35
50
70
95
120
150
185
240
300
400
500

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441

6,35/11kV EARTHED
3 CORE TABLE 17
LEAD
STEEL
DSTA
SWA

0.183
0.183
0.205
0.245
0.277
0.308
0.366
0.393
0.465
0.541
0.633
0.750
0.860

0.101
0.090
0.134
0.145
0.155
0.167
0.178
0.188
0.201
0.218
0.237
0.264
0.289

0.138
0.136
0.183
0.198
0.212
0.239
0.245
0.329
0.349
0.378
0.464
0.497
0.612

PVC
COPPER ALUMINIUM
SERVING BEDDING
OVER
&
ARMOUR SERVING
COMBINED

0.054
0.054
0.060
0.066
0.076
0.084
0.092
0.098
0.103
0.112
0.123
0.131
0.140

0.087
0.006
0.102
0.110
0.122
0.141
0.150
0.159
0.168
0.192
0.208
0.225
0.240

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

*Circular conductors

PAGE 9

Printed 2007/04/03

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441

11/11kV UNEARTHED
3 CORE TABLE 18
LEAD
STEEL
DSTA
SWA

0.222
0.221
0.256
0.276
0.319
0.372
0.404
0.461
0.540
0.583
0.672
0.781
0.907

0.140
0.144
0.147
0.156
0.168
0.180
0.190
0.201
0.215
0.230
0.248
0.275
0.296

0.189
0.189
0.201
0.214
0.229
0.245
0.330
0.350
0.372
0.398
0.484
0.517
0.632

RATED
PVC
SERVING BEDDING AREA
OVER
&
mm2
ARMOUR SERVING
COMBINED

0.065
0.064
0.067
0.077
0.084
0.092
0.098
0.104
0.111
0.118
0.127
0.134
0.145

0.106
0.105
0.112
0.186
0.142
0.151
0.160
0.175
0.188
0.202
0.217
0.231
0.250

16
25
35
50
70
95
120
150
185
240
300
400
500

PAGE 10

11kV SCREENED TYPE FULLY IMPREGNATED GENERAL PURPOSE CABLES TO SANS 97 TABLES 10 & 19.
6,35/11kV EARTHED
SINGLE CORE TABLE 10
RATED COPPER ALUMINIUM
LEAD
PVC
AREA
SERVING
mm2
OVER
ARMOUR

16
25
35
50
70
95
120
150
185
240
300
400
500
630

0.142
0.175
0.228
0.284
0.379
0.474
0.598

0.044
0.053
0.070
0.087
0.117
0.146
0.183

0.177
0.202
0.221
0.267
0.309
0.362
0.434

0.029
0.035
0.038
0.045
0.049
0.058
0.068

COPPER ALUMINIUM

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441
-

*Circular conductors

PAGE 10

Printed 2007/04/03

LEAD

0.204
0.202
0.214
0.245
0.298
0.314
0.382
0.434
0.464
0.523
0.645
0.770
0.887
-

3 CORE TABLE 19
STEEL
DSTA
SWA

0.132
0.141
0.147
0.159
0.164
0.175
0.193
0.198
0.209
0.230
0.256
0.269
0.289
-

0.178
0.188
0.196
0.207
0.215
0.231
0.251
0.334
0.351
0.386
0.467
0.544
0.617
-

RATED
PVC
AREA
SERVING
BEDDING
OVER
&
mm2
ARMOUR
SERVING
COMBINED

0.059
0.056
0.063
0.067
0.078
0.088
0.093
0.100
0.105
0.114
0.124
0.132
0.142
-

0.100
0.097
0.104
0.113
0.125
0.144
0.152
0.163
0.177
0.194
0.211
0.227
0.244
-

16
25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 11

11kV SCREENED TYPE FULLY IMPREGNATED GENERAL PURPOSE CABLES TO SANS 97 AFAA.
11/11kV UNEARTHED
SINGLE CORE
RATED COPPER ALUMINIUM
LEAD
AREA
mm2

16
25
35
50
70
95
120
150
185
240
300
400
500
630

0.142
0.175
0.228
0.284
0.379
0.474
0.598

0.044
0.053
0.070
0.087
0.117
0.146
0.183

0.224
0.235
0.268
0.308
0.359
0.419
0.453

PVC
SERVING
OVER
ARMOUR

0.037
0.039
0.045
0.054
0.058
0.067
0.078

COPPER ALUMINIUM

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441
-

*Circular conductors

PAGE 11

Printed 2007/04/03

LEAD

3 CORE
STEEL
DSTA
SWA

0.276
0.275
0.309
0.326
0.382
0.444
0.477
0.546
0.580
0.673
0.771
0.897
1.021
-

0.161
0.159
0.169
0.180
0.191
0.199
0.207
0.221
0.236
0.246
0.273
0.292
0.313
-

0.211
0.217
0.228
0.230
0.249
0.334
0.354
0.376
0.390
0.477
0.517
0.627
0.668
-

RATED
PVC
AREA
SERVING
BEDDING
OVER
&
mm2
ARMOUR
SERVING
COMBINED

0.076
0.075
0.078
0.088
0.093
0.100
0.105
0.112
0.117
0.209
0.134
0.143
0.152
-

0.122
0.121
0.126
0.144
0.153
0.164
0.177
0.191
0.200
0.213
0.230
0.246
0.261
-

16
25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 12

11kV DRAINED GENERAL PURPOSE (BELTED) CABLES FOR NORMAL SERVICE CONDITIONS & 11kV FULLY IMPREGNATED-CABLES
WITH AUGMENTED DIELECTRIC TO SANS 97 AFAA

RATED COPPER ALUMINIUM


AREA
mm2

16
25
35
50
70
95
120
150
185
240
300
400
500

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.144
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441

6,35/11kV EARTHED
3 CORE
LEAD
STEEL
DSTA
SWA

0.233
0.232
0.267
0.309
0.360
0.381
0.452
0.475
0.549
0.637
0.739
0.864
0.978

0.137
0.155
0.156
0.172
0.178
0.190
0.201
0.206
0.222
0.247
0.268
0.287
0.306

0.197
0.200
0.213
0.228
0.231
0.292
0.337
0.357
0.379
0.460
0.494
0.602
0.648

PVC
COPPER ALUMINIUM
SERVING BEDDING
OVER
&
ARMOUR SERVING
COMBINED

0.066
0.066
0.071
0.078
0.090
0.096
0.101
0.106
0.112
0.122
0.130
0.139
0.148

0.111
0.110
0.120
0.129
0.146
0.155
0.165
0.180
0.192
0.206
0.223
0.238
0.255

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

*Circular conductors

PAGE 12

Printed 2007/04/03

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441

11/11kV UNEARTHED
3 CORE
LEAD
STEEL
DSTA
SWA

0.308
0.305
0.319
0.371
0.397
0.466
0.539
0.558
0.645
0.749
0.841
0.979
1.112

0.167
0.172
0.171
0.191
0.195
0.208
0.220
0.232
0.243
0.260
0.280
0.300
0.321

0.219
0.228
0.231
0.245
0.325
0.351
0.367
0.385
0.463
0.496
0.529
0.638
0.679

RATED
PVC
SERVING BEDDING AREA
OVER
&
mm2
ARMOUR SERVING
COMBINED

0.079
0.078
0.080
0.092
0.098
0.104
0.110
0.116
0.122
0.129
0.138
0.147
0.155

0.129
0.128
0.131
0.150
0.160
0.176
0.188
0.196
0.207
0.221
0.242
0.252
0.269

16
25
35
50
70
95
120
150
185
240
300
400
500

PAGE 13

11 kV SCREENED TYPE DRAINED GENERAL PURPOSE CABLE FOR NORMAL SERVICE CONDITIONS & 11kV FULLY IMPREGNATED CABLES WITH
AUGMENTED DIELECTRIC TO SANS 97 AFAA
6,35/11kV
SINGLE CORE
RATED COPPER ALUMINIUM
AREA
mm2

16
25
35
50
70
95
120
150
185
240
300
400
500
630

0.142
0.175
0.228
0.284
0.379
0.474
0.598

0.044
0.053
0.070
0.087
0.117
0.146
0.183

LEAD

0.192
0.224
0.256
0.293
0.320
0.371
0.442

3 CORE
PVC
COPPER ALUMINIUM
SERVING
OVER
ARMOUR

0.035
0.037
0.043
0.047
0.055
0.060
0.069

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441
-

LEAD

STEEL
DSTA
SWA

0.232
0.231
0.267
0.308
0.361
0.386
0.454
0.477
0.549
0.634
0.734
0.867
1.001
-

0.146
0.155
0.156
0.166
0.179
0.191
0.198
0.212
0.220
0.244
0.263
0.283
0.276
-

* Circular conductors

PAGE 13

Printed 2007/04/03

11/11kV
SINGLE CORE

0.199
0.199
0.211
0.228
0.246
0.319
0.327
0.357
0.379
0.460
0.497
0.607
0.648
-

PVC
COPPER ALUMINIUM
SERVING BEDDING
OVER
&
ARMOUR SERVING
COMBINED

0.066
0.065
0.071
0.078
0.089
0.096
0.101
0.106
0.112
0.122
0.130
0.139
0.148
-

0.111
0.108
0.119
0.126
0.146
0.155
0.164
0.179
0.192
0.206
0.222
0.238
0.255
-

0.142
0.175
0.228
0.284
0.474
0.598

0.044
0.053
0.070
0.087
0.146
0.183

LEAD

0.255
0.267
0.308
0.359
0.456
0.536

PVC
RATED
SERVING AREA
OVER
mm2
ARMOUR

0.043
0.045
0.048
0.058
0.070
0.083

16
25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 14

12,7/22kV GENERAL PURPOSE IMPREGNATED SCREENED CABLES TO SANS 97 TABLES 11 & 20


12,7/22kV
SINGLE CORE TABLE 11
RATED COPPER ALUMINIUM
LEAD
PVC
AREA
SERVING
mm2
OVER
ARMOUR

25
35
50
70
95
120
150
185
240
300
400
500
630

0.162
0.175
0.228
0.284
0.379
0.474
0.598

0.064
0.053
0.070
0.087
0.117
0.146
0.183

0.232
0.261
0.296
0.361
0.379
0.445
0.485

0.040
0.044
0.047
0.057
0.066
0.074
0.085

COPPER ALUMINIUM

0.072*
0.100*
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
1.148
1.436
-

0.022*
0.031*
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441
-

*Circular conductors

PAGE 14

Printed 2007/04/03

LEAD

0.400
0.459
0.413
0.481
0.553
0.584
0.662
0.694
0.800
0.907
1.045
1.171
-

3 CORE TABLE 20
STEEL
DSTA
SWA

0.194
0.205
0.204
0.217
0.233
0.243
0.249
0.261
0.274
0.293
0.313
0.361
-

0.322
0.341
0.341
0.364
0.390
0.399
0.470
0.495
0.526
0.622
0.668
0.710
-

RATED
PVC
AREA
SERVING
BEDDING
OVER
&
mm2
ARMOUR
SERVING
COMBINED

0.096
0.099
0.101
0.107
0.114
0.120
0.125
0.126
0.131
0.143
-

0.167
0.175
0.172
0.189
0.198
0.208
0.218
0.229
0.246
0.261
-

25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 15

1000V LOW TENSION HEAVY DUTY CABLES TO SANS 97 AFAA


SINGLE CORE
RATED COPPER ALUMINIUM
LEAD
AREA
mm2

10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

0.142
0.175
0.228
0.284
0.379
0.474
0.598

0.044
0.053
0.070
0.087
0.117
0.146
0.183

0.187
0.202
0.234
0.298
0.330
0.375
0.465

PVC
SERVING
OVER
ARMOUR

0.023
0.027
0.030
0.037
0.045
0.055
0.059

COPPER ALUMINIUM

0.019*
0.031*
0.048
0.067
0.095
0.134
0.181
0.230
0.287
0.354
0.459
0.574
-

0.014
0.021
0.030
0.041
0.055
0.071
0.088
0.109
0.141
0.176
0.235
0.294
-

*Circular conductors

PAGE 15

Printed 2007/04/03

LEAD

0.097
0.109
0.124
0.150
0.168
0.196
0.245
0.256
0.316
0.338
0.414
0.488
0.581
0.688
-

2 CORE
STEEL
DSTA
SWA

0.064
0.067
0.073
0.098
0.107
0.116
0.127
0.135
0.148
0.157
0.174
0.191
0.208
0.231
-

0.081
0.087
0.095
0.103
0.111
0.152
0.168
0.176
0.231
0.263
0.292
0.320
0.347
0.386
-

SERVING
OVER
ARMOUR

0.027
0.032
0.034
0.040
0.042
0.153
0.055
0.062
0.070
0.077
0.090
0.098
0.106
0.117
-

RATED
PVC
AREA
BEDDING
&
mm2
SERVING
COMBINED

0.039
0.044
0.048
0.063
0.070
0.084
0.093
0.102
0.122
0.128
0.146
0.165
0.180
0.200
-

10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 16

1000V LOW TENSION HEAVY DUTY CABLES TO SANS 97 AFAA

RATED COPPER ALUMINIUM


AREA
mm2

10
16
25
35
50
70
95
120
150
185
240
300
400
500

0.029*
0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441

LEAD

0.129
0.143
0.153
0.179
0.198
0.245
0.275
0.318
0.383
0.423
0.508
0.603
0.715
0.854

3 CORE
STEEL
DSTA
SWA

0.074
0.103
0.100
0.109
0.118
0.129
0.141
0.152
0.166
0.177
0.197
0.219
0.239
0.263

0.094
0.104
0.107
0.115
0.157
0.173
0.188
0.241
0.272
0.296
0.328
0.366
0.424
0.504

PVC
COPPER ALUMINIUM
SERVING BEDDING
OVER
&
ARMOUR SERVING
COMBINED

0.037
0.039
0.040
0.043
0.051
0.056
0.064
0.072
0.083
0.091
0.100
0.111
0.121
0.131

0.048
0.064
0.064
0.071
0.085
0.095
0.106
0.124
0.141
0.148
0.169
0.188
0.205
0.225

0.038*
0.062*
0.095
0.134
0.191
0.268
0.364
0.459
0.574
0.708
0.918
1.148
-

* Circular conductors

PAGE 16

Printed 2007/04/03

0.030
0.041
0.058
0.082
0.112
0.140
0.176
0.217
0.282
0.353
0.470
0.588

LEAD

0.139
0.167
0.183
0.202
0.245
0.302
0.340
0.402
0.474
0.558
0.672
0.793
0.937
1.095

4 CORE
STEEL
DSTA
SWA

0.098
0.109
0.111
0.119
0.132
0.141
0.158
0.172
0.189
0.203
0.228
0.251
0.275
0.300

0.099
0.114
0.114
0.160
0.174
0.194
0.269
0.289
0.312
0.340
0.379
0.483
0.533
0.643

RATED
PVC
SERVING BEDDING AREA
OVER
&
mm2
ARMOUR SERVING
COMBINED

0.036
0.040
0.043
0.051
0.056
0.066
0.078
0.089
0.097
0.103
0.114
0.126
0.137
0.147

0.062
0.066
0.074
0.085
0.097
0.110
0.129
0.145
0.163
0.175
0.196
0.215
0.234
0.254

10
16
25
35
50
70
95
120
150
185
240
300
400
500

PAGE 17

3,3kV HEAVY DUTY (BELTED) CABLES TO SANS 97 AFAA


1,9/3,3kV
SINGLE CORE
RATED COPPER ALUMINIUM
LEAD
AREA
mm2

16
25
35
50
70
95
120
150
185
240
300
400
500
630

0.142
0.175
0.228
0.284
0.379
0.474
0.598

0.044
0.053
0.070
0.087
0.117
0.146
0.183

0.235
0.256
0.275
0.306
0.339
0.400
0.441

PVC
SERVING
OVER
ARMOUR

0.028
0.029
0.036
0.039
0.046
0.055
0.060

COPPER ALUMINIUM

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441
-

*Circular conductors

PAGE 17

Printed 2007/04/03

LEAD

0.238
0.229
0.246
0.269
0.299
0.329
0.391
0.415
0.487
0.570
0.666
0.793
0.905
-

3 CORE
STEEL
DSTA
SWA

0.117
0.116
0.123
0.131
0.142
0.154
0.165
0.176
0.189
0.206
0.228
0.247
0.268
-

0.154
0.152
0.162
0.174
0.187
0.257
0.277
0.296
0.316
0.343
0.379
0.481
0.507
-

SERVING
OVER
ARMOUR

0.048
0.048
0.053
0.059
0.065
0.076
0.083
0.091
0.097
0.105
0.114
0.125
0.133
-

RATED
PVC
AREA
BEDDING
&
mm2
SERVING
COMBINED

0.084
0.083
0.088
0.100
0.106
0.126
0.140
0.147
0.163
0.176
0.198
0.212
0.229
-

16
25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 18

3,3kV HEAVY DUTY (BELTED) CABLES TO SANS 97 TABLE 22


3,3/3,3kV
SINGLE CORE
RATED COPPER ALUMINIUM
LEAD
AREA
mm2

16
25
35
50
70
95
120
150
185
240
300
400
500
630

0.142
0.175
0.228
0.284
0.379
0.474
0.598

0.044
0.053
0.070
0.087
0.117
0.146
0.183

0.245
0..267
0.287
0.319
0.380
0.413
0.453

PVC
SERVING
OVER
ARMOUR

0.029
0.030
0.037
0.044
0.048
0.056
0.066

COPPER ALUMINIUM

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441

*Circular conductors

PAGE 18

Printed 2007/04/03

3 CORE TABLE 22
LEAD
STEEL
DSTA
SWA

0.240
0.246
0.264
0.286
0.315
0.348
0.402
0.431
0.498
0.587
0.685
0.814
0.927
-

0.118
0.117
0.124
0.133
0.144
0.155
0.166
0.180
0.192
0.212
0.232
0.251
0.277
-

0.163
0.161
0.170
0.183
0.197
0.270
0.291
0.308
0.327
0.354
0.386
0.489
0.519
-

SERVING
OVER
ARMOUR

0.053
0.051
0.055
0.063
0.066
0.078
0.085
0.093
0.099
0.108
0.117
0.126
0.135
-

RATED
PVC
AREA
BEDDING
&
mm2
SERVING
COMBINED

0.087
0.086
0.093
0.102
0.111
0.129
0.143
0.151
0.167
0.184
0.200
0.215
0.232
-

16
25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 19

6,6kV HEAVY DUTY (BELTED) CABLES TO SANS 97 TABLE 13 & 23


3,8/6,6kV
SINGLE CORE TABLE 13
RATED COPPER ALUMINIUM
LEAD
PVC
AREA
SERVING
mm2
OVER
ARMOUR

16
25
35
50
70
95
120
150
185
240
300
400
500
630

0.142
0.175
0.228
0.284
0.379
0.474
0.598

0.054
0.065
0.085
0.106
0.143
0.178
0.224

0.256
0.276
0.298
0.350
0.382
0.420
0.484

0.030
0.035
0.038
0.045
0.048
0.057
0.067

COPPER ALUMINIUM

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441
-

*Circular conductors

PAGE 19

Printed 2007/04/03

3 CORE TABLE 23
LEAD
STEEL
DSTA
SWA

0.264
0.265
0.288
0.310
0.340
0.398
0.433
0.508
0.560
0.624
0.715
0.841
0.969
-

0.130
0.129
0.134
0.142
0.155
0.169
0.179
0.191
0.203
0.221
0.241
0.260
0.282
-

0.177
0.175
0.180
0.191
0.272
0.294
0.299
0.319
0.340
0.370
0.427
0.501
0.597
-

SERVING
OVER
ARMOUR

0.056
0.055
0.063
0.066
0.077
0.084
0.092
0.098
0.103
0.112
0.122
0.130
0.140
-

RATED
PVC
AREA
BEDDING
&
mm2
SERVING
COMBINED

0.096
0.095
0.102
0.111
0.127
0.142
0.150
0.165
0.175
0.191
0.208
0.224
0.240
-

16
25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 20

6,6kV HEAVY DUTY (BELTED) CABLES TO SANS 97 TABLE 24


3,8/6,6kV
SINGLE CORE
RATED COPPER ALUMINIUM
LEAD
AREA
mm2

16
25
35
50
70
95
120
150
185
240
300
400
500
630

0.142
0.175
0.228
0.284
0.379
0.474
0.598

0.044
0.053
0.070
0.087
0.117
0.146
0.183

0.276
0.298
0.315
0.382
0.411
0.475
0.558

PVC
SERVING
OVER
ARMOUR

0.036
0.038
0.044
0.048
0.056
0.065
0.070

COPPER ALUMINIUM

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441
-

*Circular conductors

PAGE 20

Printed 2007/04/03

3 CORE TABLE 24
LEAD
STEEL
DSTA
SWA

0.292
0.290
0.308
0.339
0.390
0.424
0.485
0.520
0.599
0.696
0.799
0.929
1.065
-

0.139
0.138
0.142
0.151
0.163
0.174
0.186
0.195
0.209
0.232
0.251
0.272
0.291
-

0.187
0.187
0.195
0.263
0.285
0.304
0.325
0.340
0.363
0.386
0.485
0.518
0.617
-

SERVING
OVER
ARMOUR

0.064
0.063
0.066
0.076
0.084
0.092
0.098
0.102
0.109
0.117
0.126
0.135
0.144
-

RATED
PVC
AREA
BEDDING
&
mm2
SERVING
COMBINED

0.104
0.103
0.105
0.126
0.141
0.149
0.164
0.172
0.185
0.200
0.215
0.232
0.248
-

16
25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 21

11kV HEAVY DUTY (BELTED) CABLES TO SANS 97 TABLES 25 & 26

RATED COPPER ALUMINIUM


AREA
mm2

16
25
35
50
70
95
120
150
185
240
300
400
500

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441

6,35/11kV EARTHED

11/11kV UNEARTHED

3 CORE TABLE 25
LEAD
STEEL
DSTA
SWA

3 CORE TABLE 26
LEAD
STEEL
DSTA
SWA

0.319
0.319
0.348
0.402
0.433
0.498
0.528
0.600
0.677
0.737
0.865
0.980
1.171

0.150
0.159
0.161
0.180
0.181
0.192
0.205
0.212
0.231
0.241
0.265
0.286
0.310

0.257
0.268
0.277
0.296
0.305
0.325
0.341
0.367
0.385
0.472
0.501
0.612
0.638

PVC
COPPER ALUMINIUM
SERVING BEDDING
OVER
&
ARMOUR SERVING
COMBINED

0.071
0.071
0.077
0.084
0.092
0.098
0.102
0.109
0.114
0.123
0.131
0.140
0.150

0.123
0.122
0.128
0.141
0.149
0.165
0.173
0.186
0.195
0.209
0.225
0.240
0.258

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

* Circular conductors

PAGE 21

Printed 2007/04/03

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441

0.391
0.390
0.423
0.475
0.509
0.592
0.623
0.696
0.737
0.855
0.961
1.092
1.232

0.168
0.171
0.183
0.189
0.195
0.209
0.218
0.230
0.247
0.263
0.283
0.305
0.326

0.290
0.296
0.309
0.325
0.334
0.360
0.373
0.393
0.473
0.504
0.607
0.638
0.690

RATED
PVC
SERVING BEDDING AREA
OVER
&
mm2
ARMOUR SERVING
COMBINED

0.085
0.084
0.090
0.096
0.100
0.108
0.111
0.118
0.123
0.130
0.139
0.148
0.160

0.142
0.141
0.146
0.161
0.169
0.183
0.190
0.200
0.209
0.223
0.238
0.255
0.275

16
25
35
50
70
95
120
150
185
240
300
400
500

PAGE 22

11kV HEAVY DUTY SCREENED CABLES TO SANS 97 TABLES 14 & 27


6,35/11kV
SINGLE CORE TABLE 14
RATED COPPER ALUMINIUM
LEAD
PVC
AREA
SERVING
mm2
OVER
ARMOUR

16
25
35
50
70
95
120
150
185
240
300
400
500
630

0.142
0.175
0.228
0.284
0.379
0.474
0.598

0.044
0.053
0.070
0.087
0.117
0.146
0.183

0.277
0.297
0.315
0.301
0.412
0.482
0.562

0.038
0.039
0.046
0.054
0.059
0.067
0.080

COPPER ALUMINIUM

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441
-

*Circular conductors

PAGE 22

Printed 2007/04/03

3 CORE TABLE 27
LEAD
STEEL
DSTA
SWA

0.317
0.316
0.340
0.391
0.423
0.497
0.524
0.601
0.676
0.735
0.843
0.970
1.108
-

0.155
0.160
0.166
0.173
0.183
0.195
0.204
0.218
0.231
0.247
0.267
0.286
0.309
-

0.265
0.271
0.283
0.302
0.321
0.330
0.341
0.369
0.409
0.474
0.507
0.607
0.653
-

SERVING
OVER
ARMOUR

0.071
0.070
0.077
0.084
0.092
0.098
0.102
0.109
0.114
0.123
0.131
0.140
0.149
-

RATED
PVC
AREA
BEDDING
&
mm2
SERVING
COMBINED

0.123
0.122
0.127
0.141
0.149
0.165
0.172
0.185
0.195
0.208
0.225
0.240
0.257
-

16
25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 23

11kV HEAVY DUTY SCREENED CABLES TO SANS 97 AFAA


11/11kV
SINGLE CORE
RATED COPPER ALUMINIUM
LEAD
AREA
mm2

16
25
35
50
70
95
120
150
185
240
300
400
500
630

0.142
0.175
0.228
0.284
0.379
0.474
0.598

0.044
0.053
0.070
0.087
0.117
0.146
0.183

0.329
0.340
0.401
0.466
0.497
0.567
0.614

PVC
SERVING
OVER
ARMOUR

0.046
0.048
0.058
0.060
0.069
0.080
0.086

COPPER ALUMINIUM

0.046*
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861
-

0.022
0.031
0.044
0.062
0.084
0.106
0.132
0.163
0.211
0.264
0.353
0.441
-

*Circular conductors

PAGE 23

Printed 2007/04/03

LEAD

0.465
0.476
0.498
0.516
0.601
0.674
0.719
0.801
0.855
0.960
1.070
1.213
1.365
-

3 CORE
STEEL
DSTA
SWA

0.191
0.195
0.202
0.211
0.228
0.241
0.251
0.257
0.263
0.281
0.303
0.323
0.342
-

0.322
0.328
0.338
0.354
0.376
0.394
0.411
0.485
0.496
0.533
0.638
0.679
0.721
-

SERVING
OVER
ARMOUR

0.096
0.095
0.098
0.102
0.109
0.114
0.119
0.125
0.130
0.138
0.146
0.155
0.164
-

RATED
PVC
AREA
BEDDING
&
mm2
SERVING
COMBINED

0.158
0.156
0.162
0.169
0.185
0.195
0.203
0.213
0.222
0.236
0.251
0.268
0.284
-

16
25
35
50
70
95
120
150
185
240
300
400
500
630

PAGE 24

600/1000V PVC PVC SWA PVC CABLES TO SANS 1507


RATED
AREA
mm2
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

NUMBER OF CORES
1
COPPER STEEL*
0.001
0.002
0.004
0.006
0.009
0.015
0.016
0.024
0.018
0.033
0.030
0.047
0.034
0.067
0.038
0.090
0.058
0.114
0.064
0.142
0.070
0.175
0.094
0.228
0.107
0.284
0.117
0.379
0.132
0.474
0.145
0.598
0.759
0.948
-

PVC
0.016
0.020
0.022
0.028
0.033
0.043
0.047
0.055
0.061
0.077
0.090
0.109
0.124
-

COPPER
0.003
0.005
0.008
0.011
0.019
0.031
0.048
0.067
0.095
0.134
0.181
0.230
-

2
STEEL
0.016*
0.023#
0.018*
0.028#
0.022*
0.030#
0.032
0.037
0.039
0.043
0.058
0.073
0.101
0.115
0.124
-

PVC
0.017*
0.018
0.020*
0.022#
0.025*
0.026#
0.029
0.036
0.044
0.038
0.040
0.056
0.065
0.079
0.090
-

COPPER
0.004
0.007
0.011
0.017
0.029
0.046
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.609
0.861
-

DC CIRCUITS ONLY

PVC
0.019*
0.020#
0.022*
0.025#
0.027*
0.028#
0.032
0.039
0.051
0.053
0.059
0.072
0.087
0.110
0.121
0.140
0.172
0.210
0.257
-

COPPER
0.006
0.010
0.015
0.023
0.038
0.062
0.095
0.134
0.191
0.268
0.364
0.459
0.574
0.708
0.918
1.148
-

4
STEEL
0.018*
0.027#
0.025*
0.032#
0.034*
0.035#
0.037
0.043
0.066
0.073
0.103
0.118
0.133
0.151
0.209
0.230
0.251
0.355
0.398
-

PVC
0.021*
0.024#
0.025*
0.028#
0.032*
0.034#
0.036
0.044
0.060
0.062
0.071
0.095
0.111
0.133
0.156
0.187
0.217
0.270
0.326
-

2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

* 0,9 MM SWA
#1,25 MM SWA

PAGE 24
Printed 2007/04/03

3
STEEL
0.017*
0.025#
0.019*
0.029#
0.022*
0.032#
0.034
0.039
0.059
0.066
0.072
0.104
0.116
0.132
0.142
0.157
0.213
0.247
0.351
-

RATED
AREA
mm2
1,5

PAGE 25

600/1000V PVC PVC SWA PVC CABLES TO SANS 1507


RATED
AREA
5
mm2 COPPER STEEL
0,75
0.0036
0.015*
0.027#
1.0
0.0048
0.017*
0.029#
1,5
0.0073
0.024*
0.031#
2,5
0.0120
0.034
4
0.0190
0.037
6
0.0290
0.040
10
0.0480
0.060
16
0.0770
0.072
RATED
AREA
10
mm2 COPPER STEEL
0,75
0.0072
0.030
1.0
0.0097
0.035
1,5
0.0140
0.040
2,5
0.0250
0.062
4
0.0390
0.069
6
0.0570
0.096
10
0.0960
0.109
16
0.1540
0.122

6
PVC
COPPER STEEL
0.017*
0.0043
0.017*
0.019#
0.029#
0.018*
0.0058
0.017*
0.020*
0.031#
0.024*
0.0087
0.031*
0.027#
0.033#
0.030
0.0140
0.035
0.037
0.0240
0.040
0.040
0.0350
0.060
0.056
0.0570
0.066
0.070
0.0920
0.094

PVC
0.024
0.028
0.035
0.048
0.060
0.063
0.078
0.100

12
COPPER STEEL
0.0086
0.031
0.0110
0.036
0.0170
0.041
0.0290
0.064
0.0460
0.071
0.0700
0.100
Q.116
0.110
0.1850
0.127

PVC
0.017*
0.022#
0.018*
0.024#
0.026*
0.030#
0.033
0.039
0.047
0.060
0.076

NUMBER OF CORES
7
COPPER STEEL
PVC
COPPER
0.0050
0.017*
0.017*
0.0057
0.031# 0.023#
0.0068
0.019*
0.021*
0.0078
0.033# 0.026#
0.0102
0.031*
0.027*
0.0110
0.035# 0.030#
0.0170
0.036
0.034
0.0190
0.0270
0.041
0.040
0.0310
0.0400
0.062
0.053
0.0460
0.0680
0.069
0.064
0.0770
0.1080
0.098
0.079
0.1230

8
STEEL
0.018*
0.033#
0.019*
0.035*
0.034*
0.037#
0.039
0.060
0.062
0.089
0.101

PVC
0.025
0.030
0.038
0.053
0.062
0.068
0.088
0.109

NUMBER OF CORES
14
COPPER STEEL
PVC
0.0102
0.033
0.028
0.0130
0.036
0.030
0.0210
0.043
0.044
0.0340
0.067
0.057
0.0540
0.095
0.070
-

16
STEEL
0.034
0.036
0.059
0.071
0.100
-

COPPER
0.0110
0.0150
0.0240
0.0390
0.0620
-

PVC
COPPER
0.019*
0.0065
0.024#
0.021*
0.0087
0.028#
0.030*
0.0130
0.033#
0.04
0.0220
0.05
0.0350
0.06
0.0520
0.06
0.0860
0.08
0.1380

9
STEEL
0.019*
0.035#
0.021*
0.037#
0.037*
0.040#
0.048
0.066
0.071
0.101
0.118

PVC
0.032
0.033
0.051
0.061
0.077
-

19
STEEL
0.036
0.038
0.060
0.093
0.112
-

COPPER
0.0130
0.0180
0.0280
0.0460
0.0730
-

RATED
AREA
PVC
mm2
0.021* 0,75
0.026*
0.022*
1.0
0.027*
0.035*
1,5
0.037*
0.041
2,5
0.056
4
0.060
6
0.068
10
0.088
16

PVC
0.034
0.036
0.056
0.071
0.085
-

RATED
AREA
mm2
0,75
1.0
1,5
2,5
4
6
10
16

* 0,9mm SWA
# 1,25mm SWA

PAGE 25
Printed 2007/04/03

PAGE 26

600/1000V PVC PVC SWA PVC CABLES TO SANS 1507


RATED
AREA
mm2
0,75
1.0
1,5
2,5
4
RATED
AREA
mm2
0,75
1.0
1,5
2,5
4

NUMBER OF CORES
COPPER
0.014
0.019
0.029
0.048
0.077

20
STEEL
0.037
0.039
0.068
0.098
0.112

PVC
0.036
0.038
0.059
0.077
0.091

COPPER
0.015
0.021
0.031
0.051
0.081

21
STEEL
0.038
0.040
0.068
0.098
0.112

PVC
0.037
0.039
0.063
0.083
0.100

COPPER
0.017
0.024
0.035
0.058
0.092

24
STEEL
0.057
0.060
0.094
0.109
0.125

PVC
0.046
0.049
0.069
0.088
0.110

COPPER
0.019
0.027
0.039
0.066
0.104

27
STEEL
0.058
0.060
0.096
0.114
0.128

PVC
0.049
0.053
0.075
0.097
0.121

RATED
AREA
mm2
0,75
1.0
1,5
2,5
4

PVC
0.087
0.096
0.135
0.188
0.221

RATED
AREA
mm2
0,75
1.0
1,5
2,5
4

NUMBER OF CORES
COPPER
0.022
0.029
0.044
0.073
0.116

30
STEEL
0.060
0.064
0.099
0.117
0.132

PVC
0.053
0.056
0.080
0.105
0.129

COPPER
0.024
0.032
0.048
0.080
0.127

33
STEEL
0.062
0.066
0.099
0.117
0.137

PVC
0.056
0.059
0.085
0.113
0.139

COPPER
0.027
0.036
0.053
0.090
0.142

PAGE 26

Printed 2007/04/03

37
STEEL
0.066
0.069
0.108
0.127
0.144

PVC
0.060
0.063
0.091
0.123
0.148

COPPER
0.044
0.059
0.088
0.148
0.235

61
STEEL
0.101
0.107
0.134
0.193
0.217

PAGE 27

600/1000V PVC PVC SWA/ECC PVC CABLES TO SANS 1507-1990


RATED
AREA
mm2
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

COPPER
0.0051
0.0081
0.0130
0.0180
0.0320
0.0480
0.0660
0.0860
0.1250
0.1740
0.2410
0.3120
-

2
STEEL
0.014
0.021*
0.016
0.023*
0.016
0.025*
0.026
0.026
0.026
0.026
0.036
0.043
0.063
0.059
0.049
-

PVC
0.017
0.018*
0.020
0.022*
0.025
0.026*
0.03
0.04
0.04
0.04
0.05
0.06
0.07
0.08
0.090
-

NUMBER OF CORES
3
COPPER
STEEL
PVC
0.0065
0.015
0.019
0.023*
0.020*
0.0110
0.017
0.022
0.024*
0.025*
0.0160
0.017
0.027
0.027*
0.028*
0.0250
0.028
0.032
0.0410
0.028
0.039
0.0660
0.044
0.051
0.0910
0.045
0.053
0.1200
0.051
0.059
0.1740
0.073
0.072
0.2410
0.076
0.087
0.3320
0.077
0.110
0.4260
0.068
0.121
0.5130
0.082
0.140
0.6450
0.114
0.172
0.8330
0.123
0.210
1.0380
0.190
0.257

COPPER
0.0079
0.0130
0.0200
0.0290
0.0490
0.0790
0.1120
0.1490
0.2170
0.3010
0.4130
0.5300
0.6420
0.8020
1.0390
1.2930

4
STEEL
0.017
0.025*
0.018
0.027*
0.029
0.030*
0.030
0.031
0.045
0.052
0.080
0.085
0.091
0.092
0.127
0.147
0.143
0.213
0.225

PVC
0.021
0.024*
0.025
0.028*
0.032
0.034*
0.036
0.044
0.060
0.062
0.071
0.095
0.111
0.133
0.156
0.187
0.217
0.270
0.326

RATED
AREA
mm2
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

0.9mm SWA
* 1.25mm SWA

PAGE 27

Printed 2007/04/03

PAGE 28

1,9/3,3kV 3 CORE PVC PVC SWA PVC CABLES TO SANS 1507


RATED
AREA
mm2
16
25
35
50
70
95
120
150
185
240
300

1,9/3,3kV
COPPER

STEEL

PVC

0.046
0.072
0.100
0.144
0.201
0.273
0.344
0.431
0.531
0.689
0.861

0.099
0.104
0.111
0.122
0.134
0.147
0.157
0.213
0.228
0.251
0.346

0.095
0.086
0.096
0.110
0.126
0.142
0.155
0.180
0.200
0.227
0.257

PAGE 28
Printed 2007/04/03

RATED
AREA
mm2
16
25
35
50
70
95
120
150
185
240
300

PAGE 29

600/1000V STRANDED AL PVC PVC SWA PVC CABLES TO SANS 1507


RATED
AREA
mm2
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

NUMBER OF CORES
STRANDED
ALUMINIUM

STEEL*

PVC

STRANDED
ALUMINIUM

STEEL

PVC

STRANDED
ALUMINIUM

STEEL

PVC

STRANDED
ALUMINIUM

STEEL

PVC

RATED
AREA
mm2

0.0073
0.0102
0.0145
0.0210
0.0280
0.0350
0.0440
0.0530
0.0700
0.0870
0.1170
0.1460
0.1830
0.2330
0.2910

0.018
0.030
0.034
0.038
0.058
0.064
0.070
0.094
0.107
0.117
0.132
0.145
-

0.020
0.022
0.02B
0.033
0.043
0.047
0.055
0.061
0.077
0.090
0.109
0.124
-

0.0147
0.0210
0.0300
0.0410
0.0550
0.0710
-

0.043
0.058
0.073
0.101
0.115
0.124
-

0.038
0.048
0.056
0.065
0.079
0.090
-

0.0220
0.0310
0.0440
0.0620
0.0840
0.1060
0.1320
0.1630
0.2110
0.2640
-

0.066
0.072
0.104
0.116
0.132
0.142
0.157
0.213
0.247
0.351
-

0.053
0.059
0.072
0.087
0.110
0.121
0.140
0.172
0.210
0.257
-

0.0300
0.0410
0.0580
0.0820
0.1120
0.1400
0.1760
0.2170
0.2820
0.3530
-

0.073
0.103
0.118
0.133
0.151
0.209
0.230
0.251
0.355
0.398
-

0.062
0.071
0.095
0.111
0.133
0.156
0.187
0.217
0.270
0.326
-

25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

* DC CIRCUITS ONLY

PAGE 29

Printed 2007/04/03

PAGE 30

600/1000V SOLID AL PVC PVC SWA PVC CABLES TO SANS 1507


RATED
AREA
mm2

16
25
35
50
70
95
120
150
185
240
300

NUMBER OF CORES
3

SOLID
ALUMINIUM

STEEL

PVC

SOLID
ALUMINIUM

STEEL

PVC

SOLID
ALUMINIUM

STEEL

PVC

RATED
AREA
mm2

0.009
0.014
0.019
0.028
0.039
0.053
-

0.036
0.039
0.042
0.066
0.072
0.104
-

0.037
0.032
0.035
0.049
0.055
0.068
-

0.013
0.021
0.030
0.042
0.058
0.080
0.100
0.126
0.156
0.202
0.252

0.039
0.045
0.067
0.077
0.110
0.127
0.134
0.149
0.209
0.233
0.254

0.039
0.043
0.051
0.064
0.074
0.096
0.108
0.125
0.154
0.190
0.217

0.017
0.028
0.039
0.056
0.078
0.107
0.134
0.168
0.207
0.269
0.336

0.057
0.070
0.076
0.111
0.127
0.144
0.157
0.219
0.238
0.342
0.376

0.050
0.055
0.062
0.076
0.096
0.120
0.131
0.163
0.195
0.248
0.292

16
25
35
50
70
95
120
150
185
240
300

PAGE 30

Printed 2007/04/03

PAGE 31

600/1000V SOLAL PVC PVC SWA/ECC PVC CABLES TO SANS 1507


RATED
AREA
mm2

16
25
35
50
70
95
120
150
185
240
300

NUMBER OF CORES
3

2
SOLID
COPPER
ALUMINIUM

0.009
0.014
0.019
0.028
0.039
0.053
-

0.011
0.011
0.011
0.019
0.030
0.041
-

STEEL

PVC

0.026
0.024
0.028
0.042
0.041
0.062
-

0.037
0.032
0.035
0.049
0.055
0.068
-

SOLID
COPPER
ALUMINIUM

0.013
0.021
0.030
0.042
0.058
0.080
0.100
0.126
0.156
0.202
0.252

0.011
0.011
0.012
0.019
0.032
0.041
0.041
0.059
0.084
0.084
0.114

STEEL

PVC

0.029
0.031
0.050
0.053
0.074
0.079
0.089
0.086
0.119
0.144
0.139

0.039
0.043
0.051
0.064
0.074
0.096
0.108
0.125
0.154
0.190
0.217

PAGE 31
Printed 2007/04/03

STEEL

PVC

RATED
AREA
mm2

0.047
0.053
0.060
0.086
0.089
0.099
0.110
0.148
0.152
0.240
0.247

0.050
0.055
0.062
0.076
0.096
0.120
0.131
0.163
0.195
0.248
0.292

16
25
35
50
70
95
120
150
185
240
300

4
SOLID
COPPER
ALUMINIUM

0.017
0.028
0.039
0.056
0.078
0.107
0.134
0.168
0.207
0.269
0.336

0.012
0.012
0.012
0.018
0.032
0.041
0.041
0.065
0.084
0.085
0.116

PAGE 32

600/1000V PVC PVCT ASA PVC or PVC PVC SWA PVC CABLES to BS 6346
RATED
AREA
mm2

SOLID ALUMINIUM

ALIMINIUM STRIP
ARMOUR

SINGLE WIRE
ARMOUR

PVC WITH ASA

PVC WITH SWA

RATED
AREA
mm2

280 (4X70)

0.078

0.025

0.110

0.067

0.070

280 (4X70)

380 (4X95)

0.107

0.039

0.125

0.084

0.090

380 (4X95)

480 (4X120)

0.134

0.043

0.137

0.098

0.105

480 (4X120)

600 (4X150)

0.168

0.047

0.148

0.108

0.110

600 (4X150)

740 (4X185)

0.207

0.051

0.205

0.124

0.129

740 (4X185)

960 (4X240)

0.269

0.074

0.230

0.149

0.159

960 (4X240)

1200 (4X300)

0.336

0.081

0.250

0.171

0.183

1200 (4X300)

PAGE 32
Printed 2007/04/03

PAGE 33

600/1000V PVC PVCT ASA PVC CABLES to BS 6346


RATED
AREA
mm2

16
25
35
50
70
95
120
150
185
240
300

NUMBER OF CORES
3

SOLID
ALUMINIUM

ALUMINIUM
STRIP ARMOUR

PVC

SOLID
ALUMINIUM

ALUMINIUM
STRIP ARMOUR

PVC

SOLID
ALUMINIUM

ALUMINIUM
STRIP ARMOUR

PVC

RATED
AREA
mm2

0.009
0.014
0.019
0.028
0.039
0.053
-

0.008
0.007
0.008
0.009
0.018
0.020
-

0.028
0.027
0.032
0.040
0.044
0.057
-

0.013
0.021
0.030
0.042
0.058
0.080
0.100
0.126
0.156
0.202
0.252

0.008
0.009
0.010
0.019
0.021
0.035
0.037
0.041
0.045
0.067
0.074

0.028
0.036
0.042
0.054
0.062
0.079
0.088
0.107
0.126
0.149
0.177

0.017
0.027
0.038
0.055
0.076
0.104
0.131
0.164
0.202
0.262
0.328

0.009
0.010
0.011
0.022
0.024
0.039
0.043
0.049
0.071
0.078
0.084

0.033
0.044
0.051
0.066
0.076
0.095
0.109
0.129
0.154
0.187
0.222

16
25
35
50
70
95
120
150
185
240
300

PAGE 33

Printed 2007/04/03

PAGE 34

600/1000V 3 CORE PVC PVC CABLES WITH SPLIT-CONCENTRIC NEUTRAL &


EARTH CONDUCTORS TO SANS 1507
RATED AREA mm2

COPPER

PVC

RATED AREA mm2

0.012

0.011

0.018

0.015

10

0.030

0.018

10

16

0.045

0.021

16

25

0.064

0.028

25

PAGE 34
Printed 2007/04/03

PAGE 35

3.8/6.6kV SINGLE CORE TYPE A CABLE TO SANS 1339

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

Copper*
0.0513
0.0717
0.0973
0.1214
0.1484
0.1840
0.2397
0.2990
0.3813
0.4869
0.6425
0.8290
1.0380

XLPE
0.0200
0.0224
0.0250
0.0271
0.0295
0.0319
0.0363
0.0422
0.0495
0.0568
0.0626
0.0692
0.0762

AWA Diameter
1.60 mm
1.60 mm
1.60 mm
1.60 mm
1.60 mm
2.0 mm
2.0 mm
2.0 mm
2.0 mm
2.5 mm
2.5 mm
2.5 mm
2.5 mm

AWA
0.0242
0.0259
0.0277
0.0291
0.0308
0.0418
0.0446
0.0486
0.0528
0.0728
0.0785
0.0848
0.0917

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor including aluminium wire armour
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 35

Printed 2007/04/03

PVC
0.0402
0.0429
0.0474
0.0498
0.0544
0.0541
0.0649
0.0681
0.0823
0.0982
0.1107
0.1238
0.1427

Aluminium#
0.0376
0.0452
0.0545
0.0630
0.0722
0.0942
0.1129
0.1345
0.1628
0.2142
0.2611
0.3242
0.3934

Copper Tape
0.0067
0.0073
0.0080
0.0085
0.0091
0.0097
0.0106
0.0116
0.0129
0.0141
0.0154
0.0168
0.0182

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

PAGE 36

6.35/11kV SINGLE CORE TYPE A CABLE TO SANS 1339

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

Copper*
0.0520
0.0724
0.0980
0.1222
0.1492
0.1847
0.2404
0.2995
0.3816
0.4871
0.6426
0.8292
1.0382

XLPE
0.0261
0.0290
0.0321
0.0346
0.0376
0.0405
0.0447
0.0487
0.0546
0.0599
0.0659
0.0728
0.0802

AWA Diameter
1.6000
1.6000
1.6000
2.0000
2.0000
2.0000
2.0000
2.0000
2.5000
2.5000
2.5000
2.5000
2.5000

AWA
0.0263
0.0280
0.0298
0.0313
0.0417
0.0438
0.0469
0.0498
0.0540
0.0734
0.0794
0.0856
0.0926

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor including aluminium wire armour
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 36

Printed 2007/04/03

PVC
0.0436
0.0479
0.0509
0.0551
0.0639
0.0638
0.0713
0.0755
0.0866
0.0990
0.1118
0.1233
0.1440

Aluminium#
0.0397
0.0473
0.0566
0.0651
0.0831
0.0962
0.1152
0.1357
0.1640
0.2149
0.2620
0.3250
0.3942

Copper Tape
0.0075
0.0081
0.0087
0.0092
0.0098
0.0104
0.0112
0.0121
0.0132
0.0143
0.0155
0.0169
0.0184

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

PAGE 37

8.7/15kV SINGLE CORE TYPE A CABLE TO SANS 1339 AFAA

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

Copper*
0.0529
0.0733
0.0989
0.1231
0.1501
0.1856
0.2413
0.3004
0.3825
0.4880
0.6435
0.8301
1.0391

XLPE
0.0341
0.0377
0.0414
0.0445
0.0481
0.0516
0.0567
0.0615
0.0686
0.0750
0.0823
0.0907
0.0995

AWA Diameter
1.60
1.60
2.00
2.00
2.00
2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50

AWA
0.0288
0.0305
0.0409
0.0428
0.0449
0.0470
0.0500
0.0529
0.0728
0.0776
0.0833
0.0899
0.0969

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor including aluminium wire armour
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 37

Printed 2007/04/03

PVC
0.0493
0.0521
0.0578
0.0634
0.0663
0.0715
0.0782
0.0825
0.0982
0.1072
0.1202
0.1367
0.1567

Aluminium#
0.0422
0.0499
0.0678
0.0766
0.0862
0.0994
0.1183
0.1388
0.1828
0.2190
0.2659
0.3293
0.3985

Copper Tape
0.0084
0.0090
0.0096
0.0101
0.0107
0.0113
0.0121
0.0129
0.0141
0.0152
0.0164
0.0178
0.0193

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

PAGE 38

12.7/22kV SINGLE CORE TYPE A CABLE TO SANS 1339

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

Copper*
0.0537
0.0741
0.0997
0.1239
0.1509
0.1864
0.2421
0.3012
0.3833
0.4888
0.6443
0.8309
1.0399

XLPE
0.0424
0.0465
0.0508
0.0544
0.0585
0.0626
0.0685
0.0741
0.0823
0.0897
0.0982
0.1079
0.1181

AWA Diameter
1.60
2.00
2.00
2.00
2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50
2.50

AWA
0.0312
0.0416
0.0438
0.0457
0.0478
0.0499
0.0529
0.0711
0.0764
0.0815
0.0870
0.0936
0.1005

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor including aluminium wire armour
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 38

Printed 2007/04/03

PVC
0.0549
0.0587
0.0648
0.0674
0.0726
0.0757
0.0825
0.0921
0.1028
0.1147
0.1284
0.1454
0.1623

Aluminium#
0.0446
0.0609
0.0707
0.0796
0.0891
0.1023
0.1212
0.1570
0.1864
0.2230
0.2696
0.3329
0.4021

Copper Tape
0.0092
0.0098
0.0104
0.0109
0.0115
0.0121
0.0129
0.0138
0.0149
0.0160
0.0172
0.0186
0.0201

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

PAGE 39

19/33kV SINGLE CORE TYPE A CABLE TO SANS 1339

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

Copper*
0.0558
0.0761
0.1017
0.1259
0.1529
0.1885
0.2441
0.3032
0.3854
0.4908
0.6464
0.8329
1.0420

XLPE
0.0663
0.0718
0.0776
0.0824
0.0879
0.0934
0.1013
0.1088
0.1198
0.1298
0.1411
0.1542
0.1679

AWA Diameter
2.00
2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50
2.50
2.50
3.15
3.15

AWA
0.0467
0.0488
0.0511
0.0529
0.0701
0.0728
0.0766
0.0805
0.0858
0.0909
0.0964
0.1311
0.1398

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor including aluminium wire armour
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 39

Printed 2007/04/03

PVC
0.0711
0.0742
0.0798
0.0825
0.0908
0.0982
0.1030
0.1133
0.1236
0.1382
0.1496
0.1722
0.1923

Aluminium#
0.0601
0.0682
0.0779
0.0868
0.1115
0.1251
0.1449
0.1664
0.1958
0.2324
0.2790
0.3704
0.4414

Copper Tape
0.0112
0.0118
0.0124
0.0129
0.0135
0.0141
0.0150
0.0158
0.0170
0.0181
0.0193
0.0207
0.0222

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

PAGE 40

3.8/6.6kV SINGLE CORE TYPE A2 CABLE TO SANS 1339 AFAA

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

Copper*
0.0580
0.0790
0.1052
0.1299
0.1575
0.1937
0.2503
0.3106
0.3942
0.5010
0.6578
0.8458
1.0563

XLPE
0.0200
0.0224
0.0250
0.0271
0.0295
0.0319
0.0363
0.0422
0.0495
0.0568
0.0626
0.0692
0.0762

PVC
0.0174
0.0200
0.0216
0.0243
0.0258
0.0290
0.0314
0.0360
0.0440
0.0502
0.0566
0.0641
0.0723

Aluminium#
0.0134
0.0194
0.0268
0.0339
0.0414
0.0524
0.0683
0.0859
0.1100
0.1415
0.1826
0.2394
0.3016

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 40

Printed 2007/04/03

Copper Tape
0.0135
0.0146
0.0159
0.0169
0.0181
0.0193
0.0212
0.0232
0.0258
0.0283
0.0307
0.0335
0.0365

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

PAGE 41

6,35/11kV single core type A2 cable to SANS 1339 AFAA

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

Copper*
0.0595
0.0805
0.1067
0.1314
0.1590
0.1951
0.2516
0.3115
0.3949
0.5014
0.6582
0.8461
1.0567

XLPE
0.0261
0.0290
0.0321
0.0346
0.0376
0.0405
0.0447
0.0487
0.0546
0.0599
0.0659
0.0728
0.0802

PVC
0.0204
0.0218
0.0248
0.0261
0.0293
0.0309
0.0351
0.0393
0.0450
0.0506
0.0572
0.0647
0.0729

Aluminium#
0.0134
0.0194
0.0268
0.0339
0.0414
0.0524
0.0683
0.0859
0.1100
0.1415
0.1826
0.2394
0.3016

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 41

Printed 2007/04/03

Copper Tape
0.0149
0.0161
0.0174
0.0184
0.0196
0.0208
0.0225
0.0241
0.0265
0.0286
0.0311
0.0339
0.0368

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

PAGE 42

8,7/15kV single core type A2 cable to SANS 1339 AFAA

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

Copper*
0.0613
0.0823
0.1085
0.1332
0.1608
0.1969
0.2534
0.3133
0.3967
0.5032
0.6600
0.8479
1.0584

XLPE
0.0341
0.0377
0.0414
0.0445
0.0481
0.0516
0.0567
0.0615
0.0686
0.0750
0.0823
0.0907
0.0995

PVC
0.0225
0.0255
0.0288
0.0301
0.0335
0.0352
0.0396
0.0441
0.0502
0.0561
0.0629
0.0707
0.0792

Aluminium#
0.0134
0.0194
0.0268
0.0339
0.0414
0.0524
0.0683
0.0859
0.1100
0.1415
0.1826
0.2394
0.3016

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 42

Printed 2007/04/03

Copper Tape
0.0167
0.0179
0.0192
0.0202
0.0214
0.0226
0.0243
0.0259
0.0283
0.0304
0.0328
0.0357
0.0386

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

PAGE 43

12,7/22kV single core type A2 cable to SANS 1339 AFAA

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

Copper*
0.0629
0.0839
0.1101
0.1348
0.1624
0.1985
0.2550
0.3150
0.3983
0.5048
0.6616
0.8495
1.0601

XLPE
0.0424
0.0465
0.0508
0.0544
0.0585
0.0626
0.0685
0.0741
0.0823
0.0897
0.0982
0.1079
0.1181

PVC
0.0261
0.0292
0.0309
0.0341
0.0358
0.0394
0.0441
0.0466
0.0528
0.0589
0.0657
0.0766
0.0856

Aluminium#
0.0134
0.0194
0.0268
0.0339
0.0414
0.0524
0.0683
0.0859
0.1100
0.1415
0.1826
0.2394
0.3016

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 43

Printed 2007/04/03

Copper Tape
0.0183
0.0195
0.0208
0.0218
0.0230
0.0242
0.0259
0.0275
0.0299
0.0320
0.0345
0.0373
0.0402

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

PAGE 44

19/33kV single core type A2 cable to SANS 1339 AFAA

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

Copper*
0.0670
0.0879
0.1142
0.1389
0.1664
0.2026
0.2591
0.3190
0.4023
0.5089
0.6657
0.8536
1.0641

XLPE
0.0663
0.0718
0.0776
0.0824
0.0879
0.0934
0.1013
0.1088
0.1198
0.1298
0.1411
0.1542
0.1679

PVC
0.0350
0.0366
0.0404
0.0420
0.0459
0.0478
0.0529
0.0581
0.0648
0.0715
0.0790
0.0878
0.1007

Aluminium#
0.0134
0.0194
0.0268
0.0339
0.0414
0.0524
0.0683
0.0859
0.1100
0.1415
0.1826
0.2394
0.3016

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 44

Printed 2007/04/03

Copper Tape
0.0224
0.0236
0.0249
0.0259
0.0271
0.0283
0.0300
0.0316
0.0340
0.0361
0.0385
0.0414
0.0443

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

PAGE 45

3,8/6,6kV single core type B cables to SANS 1339

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

Copper*
0.0647
0.0863
0.1132
0.1384
0.1575
0.1937
0.2503
0.3106
0.3942
0.5010
0.6578
0.8458
1.0563

XLPE
0.0200
0.0224
0.0250
0.0271
0.0295
0.0319
0.0363
0.0422
0.0495
0.0568
0.0626
0.0692
0.0762

PVC
0.0176
0.0202
0.0216
0.0243
0.0258
0.0290
0.0314
0.0360
0.0440
0.0502
0.0566
0.0641
0.0723

Aluminium#
0.0134
0.0194
0.0268
0.0339
0.0414
0.0524
0.0683
0.0859
0.1100
0.1415
0.1826
0.2394
0.3016

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 45

Printed 2007/04/03

Copper Tape
0.0202
0.0220
0.0239
0.0254
0.0181
0.0193
0.0212
0.0232
0.0258
0.0283
0.0307
0.0335
0.0365

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

PAGE 46

6,35/11kV single core type B cable to SANS 1339

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

Copper*
0.0670
0.0885
0.1154
0.1406
0.1688
0.2055
0.2629
0.3115
0.3949
0.5014
0.6582
0.8461
1.0567

XLPE
0.0261
0.0290
0.0321
0.0346
0.0376
0.0405
0.0447
0.0487
0.0546
0.0599
0.0659
0.0728
0.0802

PVC
0.0207
0.0221
0.0251
0.0264
0.0296
0.0312
0.0354
0.0393
0.0450
0.0506
0.0572
0.0647
0.0729

Aluminium#
0.0134
0.0194
0.0268
0.0339
0.0414
0.0524
0.0683
0.0859
0.1100
0.1415
0.1826
0.2394
0.3016

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 46

Printed 2007/04/03

Copper Tape
0.0224
0.0242
0.0261
0.0276
0.0294
0.0312
0.0337
0.0241
0.0265
0.0286
0.0311
0.0339
0.0368

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

PAGE 47

8,7/15kV single core type B cable to SANS 1339

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

Copper*
0.0696
0.0912
0.1181
0.1433
0.1608
0.1969
0.2534
0.3133
0.3967
0.5032
0.6600
0.8479
1.0584

XLPE
0.0341
0.0377
0.0414
0.0445
0.0481
0.0516
0.0567
0.0615
0.0686
0.0750
0.0823
0.0907
0.0995

PVC
0.0228
0.0258
0.0290
0.0304
0.0335
0.0352
0.0396
0.0441
0.0502
0.0561
0.0629
0.0707
0.0792

Aluminium#
0.0134
0.0194
0.0268
0.0339
0.0414
0.0524
0.0683
0.0859
0.1100
0.1415
0.1826
0.2394
0.3016

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 47

Printed 2007/04/03

Copper Tape
0.0251
0.0269
0.0287
0.0303
0.0214
0.0226
0.0243
0.0259
0.0283
0.0304
0.0328
0.0357
0.0386

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

PAGE 48

12,7/22kV single core type B cable to SANS 1339

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

Copper*
0.0721
0.0936
0.1205
0.1457
0.1739
0.1985
0.2550
0.3150
0.3983
0.5048
0.6616
0.8495
1.0601

XLPE
0.0424
0.0465
0.0508
0.0544
0.0585
0.0626
0.0685
0.0741
0.0823
0.0897
0.0982
0.1079
0.1181

PVC
0.0264
0.0295
0.0312
0.0344
0.0361
0.0394
0.0441
0.0466
0.0528
0.0589
0.0657
0.0766
0.0856

Aluminium#
0.0134
0.0194
0.0268
0.0339
0.0414
0.0524
0.0683
0.0859
0.1100
0.1415
0.1826
0.2394
0.3016

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 48

Printed 2007/04/03

Copper Tape
0.0275
0.0293
0.0312
0.0327
0.0345
0.0242
0.0259
0.0275
0.0299
0.0320
0.0345
0.0373
0.0402

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

PAGE 49

19/33kV single core type B cable to SANS 1339

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

Copper*
0.0726
0.0879
0.1142
0.1389
0.1664
0.2026
0.2591
0.3190
0.4023
0.5089
0.6657
0.8536
1.0641

XLPE
0.0663
0.0718
0.0776
0.0824
0.0879
0.0934
0.1013
0.1088
0.1198
0.1298
0.1411
0.1542
0.1679

PVC
0.0350
0.0366
0.0404
0.0420
0.0459
0.0478
0.0529
0.0581
0.0648
0.0715
0.0790
0.0878
0.1007

Aluminium#
0.0134
0.0194
0.0268
0.0339
0.0414
0.0524
0.0683
0.0859
0.1100
0.1415
0.1826
0.2394
0.3016

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 49

Printed 2007/04/03

Copper Tape
0.0280
0.0236
0.0249
0.0259
0.0271
0.0283
0.0300
0.0316
0.0340
0.0361
0.0385
0.0414
0.0443

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

PAGE 50

3.8/6.6kV THREE-CORE TYPE A CABLE TO SANS 1339

mm2
16
25
35
50
70
95
120
150
185
240
300

Copper*
0.0614
0.0885
0.1175
0.1541
0.2154
0.2924
0.3650
0.4462
0.5530
0.7204
0.8988

XLPE
0.0433
0.0487
0.0537
0.0600
0.0673
0.0750
0.0813
0.0886
0.0958
0.1089
0.1265

SWA Diameter
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5
3.15
3.15
3.15

SWA
0.1388
0.1488
0.1576
0.2152
0.2315
0.2502
0.2660
0.2823
0.3820
0.4164
0.4521

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 50

Printed 2007/04/03

PVC
0.0740
0.0791
0.0864
0.1029
0.1137
0.1281
0.1414
0.1550
0.1733
0.2014
0.2372

Aluminium#

Copper Tape

0.0215
0.0298
0.0404
0.0582
0.0806
0.1019
0.1243
0.1574
0.2054
0.2583

0.0174
0.0186
0.0202
0.0220
0.0239
0.0254
0.0272
0.0290
0.0317
0.0347

mm2
16
25
35
50
70
95
120
150
185
240
300

PAGE 51

6.35/11kV THREE-CORE TYPE A CABLE TO SANS 1339

mm2
16
25
35
50
70
95
120
150
185
240
300

Copper*
0.0636
0.0907
0.1198
0.1563
0.2176
0.2946
0.3672
0.4484
0.5552
0.7224
0.9002

XLPE
0.0579
0.0644
0.0705
0.0782
0.0869
0.0962
0.1039
0.1127
0.1215
0.1341
0.1462

SWA Diameter
2.0
2.5
2.5
2.5
2.5
2.5
2.5
3.15
3.15
3.15
3.15

SWA
0.1553
0.2099
0.2210
0.2368
0.2531
0.2718
0.2876
0.3868
0.4092
0.4406
0.4708

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 51

Printed 2007/04/03

PVC
0.0849
0.0965
0.1045
0.1181
0.1295
0.1460
0.1642
0.1812
0.1965
0.2270
0.2550

Aluminium#

Copper Tape

0.0215
0.0298
0.0404
0.0582
0.0806
0.1019
0.1243
0.1574
0.2054
0.2583

0.0196
0.0209
0.0224
0.0242
0.0261
0.0276
0.0294
0.0312
0.0337
0.0362

mm2
50
70
95
120
150
185
240
300
400
500
630

PAGE 52

8.7/15kV THREE-CORE TYPE A CABLE TO SANS 1339 AFAA

mm2
25
35
50
70
95
120
150
185
240
300

Copper*
0.0934
0.1224
0.1589
0.2202
0.2973
0.3699
0.4511
0.5579
0.7251
0.9029

XLPE
0.0858
0.0931
0.1024
0.1130
0.1243
0.1336
0.1442
0.1548
0.1700
0.1846

SWA Diameter
2.5
2.5
2.5
2.5
3.15
3.15
3.15
3.15
3.55
3.55

SWA
0.2358
0.2473
0.2627
0.2804
0.3808
0.3989
0.4213
0.4436
0.5380
0.5714

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 52

Printed 2007/04/03

PVC
0.1176
0.1263
0.1413
0.1567
0.1757
0.1877
0.2070
0.2320
0.2625
0.2897

Aluminium#
0.0215
0.0298
0.0404
0.0582
0.0806
0.1019
0.1243
0.1574
0.2054
0.2583

Copper Tape
0.0223
0.0235
0.0251
0.0269
0.0287
0.0303
0.0321
0.0338
0.0364
0.0388

mm2
25
35
50
70
95
120
150
185
240
300

PAGE 53

12.7/22kV THREE-CORE TYPE A CABLE TO SANS 1339

mm2
35
50
70
95
120
150
185
240
300

Copper*
0.1249
0.1614
0.2227
0.2997
0.3723
0.4535
0.5603
0.7275
0.9054

XLPE
0.1163
0.1271
0.1394
0.1524
0.1632
0.1754
0.1877
0.2054
0.2223

SWA Diameter
2.5
2.5
3.15
3.15
3.15
3.15
3.15
3.55
3.55

SWA
0.2713
0.2857
0.3862
0.4098
0.4279
0.4502
0.4720
0.5700
0.6027

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 53

Printed 2007/04/03

PVC
0.1441
0.1568
0.1766
0.1983
0.2110
0.2296
0.2556
0.2851
0.3087

Aluminium#
0.0298
0.0404
0.0582
0.0806
0.1019
0.1243
0.1574
0.2054
0.2583

Copper Tape
0.0260
0.0275
0.0293
0.0312
0.0327
0.0345
0.0363
0.0388
0.0413

mm2
35
50
70
95
120
150
185
240
300

PAGE 54

19/33kV THREE-CORE TYPE A CABLE TO SANS 1339

mm2
50
70
95
120
150
185
240
300

Copper*
0.1675
0.2288
0.3058
0.3784
0.4596
0.5664
0.7337
0.9114

XLPE
0.1988
0.2153
0.2328
0.2472
0.2637
0.2802
0.3039
0.3265

SWA Diameter
3.15
3.15
3.55
3.55
3.55
3.55
3.55
3.55

SWA
0.4394
0.4605
0.5483
0.5700
0.5939
0.6184
0.6538
0.6878

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 54

Printed 2007/04/03

PVC
0.1934
0.2415
0.2636
0.2851
0.2992
0.3235
0.3601
0.3974

Aluminium#
0.0404
0.0582
0.0806
0.1019
0.1243
0.1574
0.2054
0.2583

Copper Tape
0.0336
0.0354
0.0373
0.0388
0.0406
0.0424
0.0449
0.0474

mm2
50
70
95
120
150
185
240
300

PAGE 55

3.8/6.6kV THREE-CORE TYPE B CABLE TO SANS 1339

mm2
16
25
35
50
70
95
120
150
185
240
300

Copper*
0.0775
0.1059
0.1362
0.1743
0.2373
0.2924
0.3650
0.4461
0.5530
0.7204
0.8988

XLPE
0.0433
0.0487
0.0537
0.0600
0.0673
0.0750
0.0813
0.0886
0.0958
0.1089
0.1265

PVC
0.0395
0.0445
0.0496
0.0557
0.0640
0.0710
0.0782
0.0878
0.0966
0.1124
0.1320

Aluminium#

Copper Tape

0.0215
0.0298
0.0404
0.0582
0.0806
0.1019
0.1243
0.1574
0.2054
0.2583

0.0322
0.0348
0.0373
0.0404
0.0439
0.0239
0.0254
0.0272
0.0290
0.0317

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 55

Printed 2007/04/03

mm2
16
25
35
50
70
95
120
150
185
240
300

PAGE 56

6.35/11kV THREE-CORE TYPE B CABLE TO SANS 1339

mm2
16
25
35
50
70
95
120
150
185
240
300

Copper*
0.0819
0.1103
0.1406
0.1787
0.2418
0.2946
0.3672
0.4483
0.5552
0.7224
0.9002

XLPE
0.0579
0.0644
0.0705
0.0782
0.0869
0.0962
0.1039
0.1127
0.1215
0.1341
0.1462

PVC
0.0487
0.0520
0.0585
0.0639
0.0727
0.0844
0.0908
0.1012
0.1106
0.1247
0.1394

Aluminium#

Copper Tape

0.0215
0.0298
0.0404
0.0582
0.0806
0.1019
0.1243
0.1574
0.2054
0.2583

0.0366
0.0393
0.0417
0.0448
0.0484
0.0261
0.0276
0.0294
0.0312
0.0337

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 56

Printed 2007/04/03

mm2
16
25
35
50
70
95
120
150
185
240
300

PAGE 57

8.7/15kV THREE-CORE TYPE B CABLE TO SANS 1339 AFAA

mm2
25
35
50
70
95
120
150
185
240
300

Copper*
0.0934
0.1224
0.1589
0.2202
0.2973
0.3699
0.4510
0.5579
0.7251
0.9029

XLPE
0.0858
0.0931
0.1024
0.1130
0.1243
0.1336
0.1442
0.1548
0.1700
0.1846

PVC
0.0640
0.0700
0.0785
0.0854
0.0943
0.1042
0.1135
0.1233
0.1403
0.1600

Aluminium#
0.0215
0.0298
0.0404
0.0582
0.0806
0.1019
0.1243
0.1574
0.2054
0.2583

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 57

Printed 2007/04/03

Copper Tape
0.0223
0.0235
0.0251
0.0269
0.0287
0.0303
0.0321
0.0338
0.0364
0.0388

mm2
25
35
50
70
95
120
150
185
240
300

PAGE 58

12.7/22kV THREE-CORE TYPE B CABLE TO SANS 1339

mm2
35
50
70
95
120
150
185
240
300

Copper*
0.1249
0.1614
0.2227
0.2997
0.3723
0.4534
0.5603
0.7275
0.9053

XLPE
0.1163
0.1271
0.1394
0.1524
0.1632
0.1754
0.1877
0.2054
0.2223

PVC
0.0857
0.0952
0.1042
0.1141
0.1249
0.1392
0.1500
0.1709
0.1835

Aluminium#
0.0298
0.0404
0.0582
0.0806
0.1019
0.1243
0.1574
0.2054
0.2583

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 58

Printed 2007/04/03

Copper Tape
0.0260
0.0275
0.0293
0.0312
0.0327
0.0345
0.0363
0.0388
0.0413

mm2
35
50
70
95
120
150
185
240
300

PAGE 59

19/33kV THREE-CORE TYPE B CABLE TO SANS 1339

mm2
50
70
95
120
150
185
240
300

Copper*
0.1675
0.2288
0.3058
0.3784
0.4595
0.5664
0.7337
0.9114

XLPE
0.1988
0.2153
0.2328
0.2472
0.2637
0.2802
0.3039
0.3265

PVC
0.1302
0.1426
0.1540
0.1709
0.1807
0.1952
0.2165
0.2381

Aluminium#
0.0404
0.0582
0.0806
0.1019
0.1243
0.1574
0.2054
0.2583

*variation factor applies to a copper conductor including copper tape screen


#variation factor applies to an aluminium conductor
variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 59

Printed 2007/04/03

Copper Tape
0.0336
0.0354
0.0373
0.0388
0.0406
0.0424
0.0449
0.0474

mm2
50
70
95
120
150
185
240
300

PAGE 60

STANDARD SIGNALLING CABLES (OUTDOOR) TO SATS SPECIFICATION NO CSE 49E


SIZE
CORES
COPPER
PVC
SWA

0,9mm2
2
0.0013
0.0150
0.0150

3
0.0020
0.0160
0.0160

4
0.0025
0.0170
0.0170

6
0.0038
0.0210
0.0200

9
0.0054
0.0270
0.0330

12
0.0077
0.0320
0.0350

16
0.010
0.039
0.038

21
0.014
0.046
0.029*

27
0.017
0.054
0.033*

37
0.024
0.075
0.037*

52
0.034
0.098
0.043*

61
0.039
0.110
0.044*

SIZE
CORES
COPPER
PVC
SWA

2
0.0030
0.017
0.017

3
0.0045
0.0190
0.0180

4
0.006
0.021
0.019

6
0.009
0.025
0.023

9
0.014
0.033
0.034

10
0.018
0.039
0.017

16
0.024
0.046
0.025*

21
0.032
0.061
0.033*

27
0.041
0.075
0.037*

37
0.056
0.094
0.041*

52
0.079
0.129
0.048*

61
0.093
0.149
0.052*

SIZE
CORES
COPPER
PVC
SWA

2
0.004
0.019
0.018

3
0.006
0.021
0.019

4
0.008
0.025
0.021

6
0.012
0.030
0.034

9
0.017
0.040
0.018*

1,6mm2
12
16
0.024
0.032
0.045
0.059
0.029*
0.033*

21
0.042
0.074
0.037*

27
0.053
0.087
0.041*

37
0.073
0.113
0.045*

52
0.102
0.160
0.054*

61
0.121
0.175
0.058*

SIZE
CORES
COPPER
PVC
SWA

2
0.0051
0.0230
0.0210

2,5mm2
3
4
0.0078
0.010
0.0250
0.028
0.0220
0.024

37
0.094
0.123
-

SIZE
CORES
COPPER
PVC
SWA

2
0.008
0.026
0.023

3
0.012
0.028
0.024

4
0.016
0.032
0.035

4mm2
6
0.023
0.037
0.020

9
0.035
0.057
0.026

12
0.047
0.066
0.030

21
0.083
0.096
0.036*

SIZE
CORES
COPPER
PVC
SWA

2
0.012
0.032
0.032

6mm2
3
4
0.018
0.024
0.036
0.038
0.035
0.038

6
0.035
0.049
0.030

SIZE
CORES
COPPER
PVC
SWA

2
0.020
0.036
0.039

10mm2
4
0.040
0.041
0.023*

12
0.120
0.090
0.043*

2
0.031
0.043
0.028*

16mm2
3
4
0.048
0.062
0.051
0.058
0.031*
0.033*

6
0.073
0.073
0.037*

1,4mm2

*Galvanised Ferrous Tape


PAGE 60

Printed 2007/04/03

PAGE 61

STANDARD SIGNALLING CABLES (INDOOR) TO SATS SPECIFICATION NO CSE 49G


SIZE

CORES

COPPER

PVC

0,5mm2

50
70
12
20
60
68
80
1
4
10
20
1
12
1
2
3
6
12
2
3

0.0110
0.0140
0.0030
0.0060
0.0170
0.0210
0.0230
0.0010
0.0025
0.0060
0.0120
0.0150
0.1800
0.0320
0.0650
0.0980
0.1980
0.3960
0.1310
0.1960

0.0210
0.0250
0.0100
0.0120
0.0210
0.0300
0.0330
0.0009
0.0120
0.0150
0.0180
0.0100
0.0750
0.0210
0.0510
0.0530
0.1140
0.1730
0.0590
0.0710

0,63mm2

0,9mm2

16mm2
35mm2

70mm2

PAGE 61
Printed 2007/04/03