You are on page 1of 252

Final Drawings

Customer:

DSME

Hull / Project:

H1195 / H1196

WS-Ordernumber: 452946646 / 452946721

Contents
1.

Installation Instruction, Graphical Symbols

2.

HFO

3.

LO

Installation Instructions
For

Separators

No.

2058-9601-020

Edition

0211

GEA Mechanical Equipment / GEA Westfalia Separator Group

2058-9601-020 / 0211

ORIGINAL INSTRUCTION MANUAL


Subject to modification!
The authors are always grateful for comments and suggestions for improving
the documentation. They can be addressed to:
GEA Mechanical Equipment

GEA Westfalia Separator Group GmbH


Werner-Habig-Str. 1, 59302 Oelde (Germany)
Phone +49 2522 77-0, Fax +49 2522 77-2488
ws.info@geagroup.com, www.westfalia-separator.com

Westfalia Separator

2058-9601-020 / 0211

Preface
These installation guidelines
are part of the overall documentation compiled for the separator.
describe the procedures for constructing, manufacturing and designing separators.
contain fundamental instructions for installing separator installations.
contain general guidelines for separator installations.
These guidelines specify the minimum specifications for designing and
constructing frames, tanks, piping and the electrical installation.
Putting together and installing the installation components must be
carried out in accordance with the order-specific documents:
Installation diagram and equipment list
Dimensioned drawing (notes on required space for operating and
servicing, minimum clearance from walls/pillars or other machines)
We reserve the right to carry out technical modifications on the
separator!
Attention must be paid to the operating, maintenance and mounting
instruction manuals of all units and fittings.

For your safety


Take special care when carrying out operations marked with this
symbol otherwise danger to life!
Strictly adhere to instructions marked with this symbol.
This avoids damage to the separator and other equipment.
Note: This symbol is not a safety precaution but rather a reference to infor-

mation which help to better understand the separator or plant components and the processes.

Use only genuine spare parts from GEA Westfalia Separator. The original spare parts are listed in the spare parts catalog.
The use of non-genuine parts leads to:
safety risks,
reduced durability of these parts,
reduced availability of the separator and
increased service requirement.
If a safety risk occurs when using non-original spare parts, this may have legal
consequences for the responsible persons. In such cases, GEA Westfalia
Separator accepts no liability or warranty claims.

Westfalia Separator

2058-9601-020 / 0211

General
1.1
1.2
1.3
1.4
1.4.1
1.5
1.5.1
1.6

2.7
2.7.1
2.8
2.9
2.9.1
2.9.2

37

Compressed air quality .......................................................................... 38


Supply pressure ..................................................................................... 38
Compressed air consumption of the separators OSD, OSE and OTC.. 38

Product lines
5.1
5.2
5.3

33

Water quality .......................................................................................... 34


Supply pressure and temperature ......................................................... 34
Water connection for operating, filling and displacement water ............ 35
Dimensions and number of consumers ................................................. 35
Water quantity ........................................................................................ 36

Compressed air
4.1
4.2
4.3

19

Space requirement for separators ......................................................... 20


Separators with belt drive ...................................................................... 20
Bowl weights .......................................................................................... 22
Required hoist specifications for separators.......................................... 23
Ventilating the separator room .............................................................. 23
Foundations ........................................................................................... 25
Securing the separators ......................................................................... 27
Separators OSD 6, 18, 35, 60, OSE 5, 10, 20, 40, 80 and
OTC 5, 10, 20 ........................................................................................ 28
Welding procedure for fastening the foundation frame ......................... 29
Installing the separator .......................................................................... 30
Vibrations ............................................................................................... 31
Pipelines on the separator ..................................................................... 32
Product line ............................................................................................ 32
Operating, filling and displacement water lines ..................................... 32

Operating, filling and displacement water


3.1
3.2
3.3
3.4
3.5

Safety precautions ................................................................................... 8


Material .................................................................................................... 8
Installation ................................................................................................ 8
Storage .................................................................................................. 10
Installation of controls ............................................................................ 10
Transport................................................................................................ 12
Transporting the separator .................................................................... 14
Preservation measures on site .............................................................. 18

Separator
2.1
2.1.1
2.2
2.3
2.4
2.5
2.6
2.6.1

39

General .................................................................................................. 40
Pipe cross-sections ................................................................................ 40
Functional description ............................................................................ 40

Westfalia Separator

2058-9601-020 / 0211

5.4
5.5
5.6
5.6.1
5.6.2
5.7
5.8
5.9
5.9.1
5.9.2
5.9.3
5.9.4
5.10
5.11

Solids tank
6.1
6.1.1
6.1.2
6.2
6.2.1
6.2.2
6.2.3
6.3
6.3.1

Information on pressure monitoring ....................................................... 40


Piping ..................................................................................................... 42
Maximum suction head .......................................................................... 43
Pressure line .......................................................................................... 43
Pre-filter ................................................................................................. 44
Feed pump ............................................................................................. 44
Oil pre-heater ......................................................................................... 44
Installation examples ............................................................................. 45
Steam-heated plate heat exchanger with (PI controlled) control valve . 45
Steam-heated tubular heat exchanger with (PI controlled)
control valve ........................................................................................... 46
Thermal oil-heated plate heat exchanger with (PI controlled) control
valve....................................................................................................... 47
Thermal-oil-heated tubular heat exchanger with (PI controlled)
control valve ........................................................................................... 48
Securing plate heat exchangers ............................................................ 49
Safety valve ........................................................................................... 50

Recommended criteria for solids tank ................................................... 52


Tank vent ............................................................................................... 53
Set-up of the solids tank venting ........................................................... 54
Solids discharge lines ............................................................................ 55
Solids discharge lines with shut-off flap................................................. 56
Standard installation of shut-off flaps .................................................... 56
Installation recommendation for shut-off flaps ....................................... 57
Operating and dirty water discharge lines ............................................. 58
Separators of OSD and OSE ................................................................. 58

Electrical installation
7.1
7.1.1
7.1.2
7.1.3
7.1.4
7.2
7.3
7.3.1
7.3.2
7.3.3
7.4
7.5
7.6
7.6.1
7.6.2
7.6.3
7.6.4
7.6.5
7.7
7.8

51

61

Control cabinet ....................................................................................... 62


Electrical connection .............................................................................. 64
External voltages ................................................................................... 64
Shipboard operation .............................................................................. 65
Onshore operation ................................................................................. 65
Electro-magnetically compatible installation .......................................... 66
Valves .................................................................................................... 67
Solenoid valve block .............................................................................. 67
Terminal box .......................................................................................... 68
Separator with sensor bloc .................................................................... 69
Dual-purpose thermometer .................................................................... 70
Electrical installation of transmitters and electric motors ....................... 71
Electrical execution ................................................................................ 71
Earthing the separator ........................................................................... 72
Voltage equalisation of the separator .................................................... 72
Voltage equalization of the electric heater ............................................. 73
Voltage equalization of the foundation frame ........................................ 73
Voltage equalisation of the control cabinet ............................................ 74
Electric motors procured by the customer ............................................. 75
Installation and operation of control units .............................................. 76

Westfalia Separator

2058-9601-020 / 0211

Note
Notes
Notizen
Anotaciones

Muistiinpanot

Notater
Notes
Note

Westfalia Separator

2058-9601-020 / 0211

General
1.1
1.2
1.3
1.4
1.4.1
1.5
1.5.1
1.6

Safety precautions ................................................................................... 8


Material .................................................................................................... 8
Installation ................................................................................................ 8
Storage .................................................................................................. 10
Installation of controls ............................................................................ 10
Transport................................................................................................ 12
Transporting the separator .................................................................... 14
Preservation measures on site .............................................................. 18

Westfalia Separator

2058-9601-020 / 0211

1.1

Safety precautions
Pay special attention to the safety precautions contained in the
overall documentation compiled for the separator!

1.2

Material
The specified material must conform to the standards set out in these installation guidelines as a minimum requirement.
All materials used must be new and from the same series.

1.3

Installation

Fig. 1

1
2
3
4
5
6

Installation example

Separator:
Separator foundation
Control unit
Control cabinet
Preheater
Solids tank

7
8
9
10
11

Solids tank venting


Crane
Cleaning table
Aeration
Venting

The applicable regulations and standards of classification societies or other


authorised bodies must be observed.
All lubricating points and the gear / drive housing of the separator must be
easily accessible without having to remove pipes or gratings.
All operating elements must be within comfortable reach of the operator and
at a suitable height.
Operating elements must not be mounted higher than 1800 mm above the
working platform.
All units must be arranged so that they do not cramp the working area and so
that they can be safely serviced and operated.

Westfalia Separator

2058-9601-020 / 0211

All fixed piping and fittings must be safely supported to reduce vibrations and
movement to a minimum.
Contact points or supports must be fitted so that the pipes are able to move
with changing temperatures without creating tension in the pipes.
Pipes and pipe connections must be accessible for maintenance.
Pipes must not be used for supporting distributors or appliances.
These regulations and standards do not apply to small purpose-built parts
whose durability, accessibility and operation are not influenced. They must be
fitted in accordance with the manufacturer's recommendations.
No galvanized parts may be fitted in product-carrying lines (e.g. heavy oil,
diesel oil, steam lines and thermal oil lines). This does not apply if type-tested
pipe joints are fitted in pipe trace heating systems.
Y-strainers should preferably be fitted horizontally with the strainer insert
pointing downwards or to the side (turned through 90).
If this is not possible for space reasons, the dirt pan can be fitted vertically
with a throughflow from top to bottom. In this case, ensure that the strainer
can be dismantled.

Westfalia Separator

10

2058-9601-020 / 0211

1.4

Storage
Parts may be stored only in original GEA Westfalia Separator transport packaging.
A storage time of more than 12 months is only possible after consulting the
manufacturer.
The storage site should be a closed, dry room.
The storage temperature must not be below 5C (41 F) and must not exceed
50 C (122 F).
IMPORTANT:
Outdoor exposure is not admissible!

Pay attention to the following points on storage and transport packaging.

Handle fragile goods with care!

Protect the goods against moisture and humidity.

Protect the goods against heat!

Pay attention when erecting the goods.

1.4.1 Installation of controls


IMPORTANT:
Outdoor exposure is not admissible!
Select the installation site so that
the control unit is not exposed to dust and aggressive atmosphere.
the control unit is not installed in an excessively humid environment or
damp area.
the sun cannot shine on the control panel or displays making operation and
observation more difficult.
heating up of the control unit is avoided.
Where appropriate, check screw-type and plug-type connectors for secure
contact.
Westfalia Separator

11

2058-9601-020 / 0211

Connect thermostatically controlled cabinet heating to external voltage and


switch it on.
The control cabinet heating must switch on before the temperature drops below the dew point.
Bedewing can occur during the night which is not good for electronic apparatus.
Check that the line voltage and frequency conform to the connection data of
the control unit (see nameplate).
Pay attention to admissible installation and operating data:
Voltage fluctuations
Frequency fluctuations
Ambient temperatures
Atmospheric humidity
Installation height
Transport temperatures

+/- 10 % of the line voltage


+/- 2 % of the line voltage
+ 5 to + 45 C (41 to 113 F)
max. 50 % at 40 C (104 F)
max. 90 % at 20 C (68 F)
above sea level up to 1000 m
25 to + 55 C (13 to 131 F)

IMPORTANT:
Improper installation and operation discharges the supplier from the warranty
obligation.

Westfalia Separator

12

2058-9601-020 / 0211

1.5

Transport
The adjacent packing illustrates a
seaworthy packaging from GEA Westfalia Separator.

Fig. 2

After removing the side boards and


filling material, the bottom board can
be used as a special pallet for fork
lift trucks.

Fig. 3

If no forklift trucks are available,


transport the case with the aid of a
crane (see diagram).
Attach the ropes to the points on the
packing case as marked on the
packing case.

Fig. 4

Westfalia Separator

13

2058-9601-020 / 0211

Attach ropes round the case and


hang them into the load hook of the
crane.
CAUTION!
Wind one piece of rope twice
round the hook to prevent the
ropes from slipping.

Fig. 5

Westfalia Separator

14

2058-9601-020 / 0211

1.5.1 Transporting the separator


IMPORTANT:
To avoid damage, the bowl must be
removed from the separator before
transport.
The separator is normally delivered
without installed bowl.
Exception:
The OTC 2, OTC 3, OSD 2 and
OSE 5 separators are delivered and
transported with installed bowl.
Fig. 6

CAUTION!
Prevent accidents by using suitably rated hoists for transport and installation.
When transporting rope, make sure
that one piece of rope is wound
twice round the hook to prevent the
ropes from slipping.
The rope must be properly attached
to the separator.
Ensure that no pulling or pushing
forces act on machine parts when
using ropes.

Fig. 7

The following examples show how the transport ropes must be attached on the
different frame designs (see Fig. 8 Fig. 13).

Westfalia Separator

15

2058-9601-020 / 0211

For OSD 6 or 18 and OSE 5, 10 and 20 separator with belt drive


Screw double nipple 1 into the hole
in the frame.

Fig. 8

Attach the transport ropes


to the machine as illustrated and
hang them into the load hook of
the hoist as illustrated.
Wind one piece of rope twice
round the hook to prevent the
ropes from slipping.
Make sure that the ropes do not
damage any machine components.
Do not use the eye bolt of the
motor to suspend the separator.
Make sure the machine touches
down gently.

Fig. 9

Westfalia Separator

16

2058-9601-020 / 0211

For OSD 35 and OSE 40 separator with belt drive


Screw two eye bolts 1 into the upper
section of the frame.
Screw double nipple 2 into the hole
in the frame.

Fig. 10

Attach the transport ropes


around the double nipple.
Thread through the eye bolts and
hang them into the load hook of
the hoist as illustrated.
Wind one piece of rope twice
round the hook to prevent the
ropes from slipping.
Make sure that the ropes do not
damage any machine components.
Do not use the eye bolt of the
motor to suspend the separator.
Make sure the machine touches
down gently.

Fig. 11

Westfalia Separator

17

2058-9601-020 / 0211

For OSD 60, OSE 80 and 120 separator with belt drive
Check that
two eye bolts 1 are screwed into
the upper section of the frame.
Screw two eye bolts 2 with washers 3 into the intermediate flange /
frame holes.

Fig. 12

Attach the transport ropes


Thread through the four eye bolts
and
hang them into the load hook of
the hoist as illustrated.
Wind one piece of rope twice
round the hook to prevent the
ropes from slipping.
Make sure that the ropes do not
damage any machine components.
Do not use the eye bolt of the
motor to suspend the separator.
Make sure the machine touches
down gently.

Fig. 13

Westfalia Separator

18

2058-9601-020 / 0211

1.6

Preservation measures on site


After installation until commissioning
All parts such as tools, spare parts and bowl must be stored in the original
packaging in a suitable place until commissioning.
The parts must be stored at 5 to 50 C (41 - 122 F) in dry, weatherproof
rooms to prevent the packaging from getting damaged.
The spindle and gear/drive chamber are lubricated at the factory which protects them for a period of 12 months.
In the case of a storage and standstill period of longer than 12 months, the
time-dependent maintenance intervals specified in the instruction manual
must be adhered to before putting the machine back into operation.
After this time (12 months) has expired, it must be checked at 12 monthly intervals that all bearings and the spindle have sufficient lubrication.
Oil to be used:
Shell oil S.7294 (SAE 30/SAE 50) for bearings and spindle,
roller bearing grease for the spindle cap.

Westfalia Separator

19

2058-9601-020 / 0211

Separator
2.1
2.1.1
2.2
2.3
2.4
2.5
2.6
2.6.1
2.7
2.7.1
2.8
2.9
2.9.1
2.9.2

Space requirement for separators ......................................................... 20


Separators with belt drive ...................................................................... 20
Bowl weights .......................................................................................... 22
Required hoist specifications for separators.......................................... 23
Ventilating the separator room .............................................................. 23
Foundations ........................................................................................... 25
Securing the separators ......................................................................... 27
Separators OSD 6, 18, 35, 60, OSE 5, 10, 20, 40, 80 and
OTC 5, 10, 20 ........................................................................................ 28
Welding procedure for fastening the foundation frame ......................... 29
Installing the separator .......................................................................... 30
Vibrations ............................................................................................... 31
Pipelines on the separator ..................................................................... 32
Product line ............................................................................................ 32
Operating, filling and displacement water lines ..................................... 32

Westfalia Separator

20

2058-9601-020 / 0211

2.1

Space requirement for separators


No piping may be laid in the operating area apart from the feed and discharge
lines for the separator.

2.1.1 Separators with belt drive


The hatched area represents the operating area.
See the following table to determine the operating area.

Before installing the separator, pay special attention to the removal dimension
X for the electric motors!
Front view of separator

Fig. 14

Side view of separator

Fig. 15

Top view of separator

Fig. 16

Westfalia Separator

21

2058-9601-020 / 0211

Table for determining the operating area for separators with belt drive
Separator
model
OTC 2
OTC 3
OTC 5
OTC 10
OTC 20
OSD 2
OSD 6
OSD 18
OSD 35
OSD 60
OSE 5
OSE 10
OSE 20
OSE 40
OSE 80

A
800
800
1400
1400
1400
800
1400
1400
1800
2000
1400
1400
1400
1800
2000

B
300
300
600
600
600
300
600
600
700
800
600
600
600
700
800

Dimensions in mm
D
E
F
G
800
120
280
800
120
280
1200 400 1250 375
1400 550 1450 540
1400 550 1550 630
800
200
280
1400 550 1450 540
1400 550 1550 630
1800 650 1950 850
2000 700 2500 1000
1200 400 1250 375
1400 550 1500 540
1400 550 1650 630
1800 650 2080 850
2000 700 2250 1000

X
100
100
540
540
630
100
180
180
230
300
540
180
180
230
300

Y
150
150
150
150
150
150
150
150
200
200
150
150
150
200
200

Westfalia Separator

22

2058-9601-020 / 0211

2.2

Bowl weights

Fig. 17

Table with data for rating the lifting device


Separator model
OSD 6
OSD 18
OSD 35
OSD 60
OTC 5
OTC 10
OTC 20

Separator model
OSE 5
OSE 10
OSE 20
OSE 40
OSE 80

Bowl weight
[kg]

255
300
425
536
220
260
315

270
320
420
530
225
265
310

42
72
190
360
25
40
52

Bowl weight
[kg]

220
260
315
440
560

225
265
310
450
570

30
45
65
205
400

Westfalia Separator

23

2058-9601-020 / 0211

2.3

Required hoist specifications for separators


Flat belt separators
The hoist must be travel-type or swivel-type.
The hoist must be arranged so as to enable the following:
Vertical fitting and removal of the bowl (see section 2.1.1, table - dimension
F).
Horizontal removal and fitting of the drive motor (see section 2.1.1, table dimension X).

2.4

Ventilating the separator room


Pay attention to the correct arrangement of the air feed and discharge lines so
that
the separator room is efficiently ventilated,
the admissible room temperature normally max. 45 C (113 F) is not
exceeded.
The rating of the electrical apparatus is critical in this respect.
IMPORTANT:
If the admissible temperatures are exceeded, additional measures must be
taken. Maintenance intervals and maintenance measures may have to be adjusted accordingly.
Installation example of a ventilation
system

1
2

Aeration
Venting

Fig. 18

Approximate values for air exchange


For small closed separator rooms
For large separator rooms
For niches in engine rooms

-1

30 - 50 h
-1
15 - 20 h
-1
50 - 70 h

Westfalia Separator

24

2058-9601-020 / 0211

Table for air volumes pressed out of the housing


Separator
model
OTC 2
OTC 3
OTC 5
OTC 10
OTC 20
OSD 2
OSD 6
OSD 18
OSD 35
OSD 60
OSE 5
OSE 10
OSE 20
OSE 40
OSE 80

Air volume
[m/h]
10
10
10
10
10
10
10
30
100
150
10
10
30
100
150

Westfalia Separator

25

2058-9601-020 / 0211

2.5

Foundations
In order to avoid the influence of external vibrations,
Foundations and foundation frames for separators must not be rigidly connected to other foundations.
IMPORTANT:
If the foundation does not have adequate rigidity and flexural strength, this
may result in loss of warranty.
Installation example for a foundation frame

1 Foundation

Fig. 19

The foundation frames must be designed so that dimensions a and b in


the table below are adhered to.
When using other sections, the section modulus of the U-sections must
not be lower than the value specified
in DIN 1026.
The foundation must be rigid with a
maximum admissible deflection of
1:250.
The separator feet must be fastened
on the neutral axis of the frame.
Fig. 20

Westfalia Separator

26

2058-9601-020 / 0211

Table for dimensioning foundation frames


Separator
model
OTC 2
OTC 3
OTC 5
OTC 10
OTC 20
OSD 2
OSD 6
OSD 18
OSD 35
OSD 60
OSE 5
OSE 10
OSE 20
OSE 40
OSE 80

Dimensions in mm
a
b
80
60
80
60
80
60
80
60
80
60
80
60
140
60
140
60
180
70
180
70
140
60
140
60
140
60
180
70
180
70

Westfalia Separator

27

2058-9601-020 / 0211

2.6

Securing the separators


The following sections show how to secure the different separators:
Separators OTC 2, OTC 3, OSD 2
Assembly of separators with the aid of
rubber-metal cushions on a steel foundation frame.

Fig. 21

Screw rubber-metal cushions 4 into


foundation 5.
Screw studs 2 into rubber-metal
cushions 4.
Place plate 3 over the studs.
Place the separator on plate 3 and
bolt tight with hexagon nuts 1.

Fig. 22

ATTENTION!
The tightening torque for the stud screw 2 (M10) must be 30 Nm.

Westfalia Separator

28

2058-9601-020 / 0211

2.6.1 Separators OSD 6, 18, 35, 60, OSE 5, 10, 20, 40, 80 and OTC 5, 10, 20
Align separator 1 with feet 2 and
plates 3 on foundation 4.
Tack plates 3.
Unscrew screws 5.
Lift separator with feet (see section
1.5.1).
Weld plates 3 to foundation 4.
Place the separator on plates 3 and
bolt tight with hexagon nuts 5.
Screw tight hex head screws 6.
Fig. 23

ATTENTION!
The torques for the hex head screw 6 are specified in the table below.
Separator model
OSD 6
OSD 18
OSD 35
OSD 60

Hex head screw

Torque

M 12

52 Nm

M 16

100 Nm

M 12

52 Nm

M 16

100 Nm

M 12

52 Nm

OSE 5
OSE 10
OSE 20
OSE 40
OSE 80
OTC 5
OTC 10
OTC 20

Westfalia Separator

29

2058-9601-020 / 0211

2.7

Welding procedure for fastening the foundation frame


The following sections show the welding procedure for fastening the foundation
frame:
Mounting the separator installations
on board of a ship
The foundation frame 2 can be directly welded onto the steel structure
2 from the shipyard.

Fig. 24

Example 1
The length of the weld seams must
be 100 mm.
The distance between the weld
seams must be approx. 350 mm.
This means that that there are 3 weld
seams with a length of 100 mm along
a length of one metre.

Fig. 25

Example 2
The foundation frame can likewise
be welded all the way round.
Detail view
In this view you can see an example
for welding the foundation frame to the
steel structure.
The letter X indicates a fillet weld.

Fig. 26

Westfalia Separator

30

2058-9601-020 / 0211

2.7.1 Installing the separator


Mounting the separator installations
on board of a ship
The frames must be fitted beneath
the separator feet.
The dimension a for the frame distance must be observed.
The position of the separator feet is
given in section 2.1.1.

Fig. 27

The dimension a for the frame distance is given in the table below for
the respective separator model.

Fig. 28

Separator model
OTC 2
OTC 3
OTC 5
OTC 10
OTC 20
OSD 2
OSD 6
OSD 18
OSD 35
OSD 60
OSE 5
OSE 10
OSE 20
OSE 40
OSE 80

Dimension a
[mm]
452 mm
452 mm
326 mm
350 mm
425 mm
452 mm
350 mm
425 mm
555 mm
700 mm
326 mm
350 mm
425 mm
555 mm
700 mm

Westfalia Separator

31

2058-9601-020 / 0211

2.8

Vibrations

Fig. 29

Admissible vibration value at the


reference point
[mm/s]
OTC 2
1,8
2,8
OTC 3
1,8
2,8
OTC 5
2,8
4,5
OTC 10
2,8
4,5
OTC 20
2,8
4,5
OSD 2
1,8
2,8
OSD 6
2,8
4,5
OSD 18
2,8
4,5
OSD 35
2,8
4,5
OSD 60
2,8
4,5
OSE 5
3,5
5,5
OSE 10
2,8
4,5
OSE 20
2,8
4,5
OSE 40
2,8
4,5
OSE 80
2,8
4,5
Measured at separator standstill and normal ship operating conditions
Measured with separators in operation
The Vibro sensor is attached in this range
Separator
model

Tolerable vibration values at the


separator installation surface
max. [mm/s]

Limit values for Vibro 1


with installed vibration
sensor
[mm/s]
2,8
2,8
4,5
4,5
4,5
2,8
4,5
4,5
4,5
4,5
5,5
4,5
4,5
4,5
4,5

Westfalia Separator

32

2058-9601-020 / 0211

2.9

Pipelines on the separator


The following sections describe the general set-up of the piping system in the
separator installation:

2.9.1 Product line


Product lines must be laid
in accordance with the guidelines of GEA Westfalia Separator or
in accordance with the requirements of the classification societies.
Use only genuine parts from GEA Westfalia Separator!
The lines must be flushed before commissioning to protect the valves and
units.
The following lines must have no rigid connection with the separator in order
to prevent vibrations:
Product feed and discharge
Water connection
Solids discharge
Dirty water discharge
Frame drain
This can be realised by means of hoses or compensators, whereby there are
special requirements for shockproof separators.
Hose pipes must be laid so that they cannot be twisted, kinked, clamped or
rubbed.
Use only hoses from GEA Westfalia Separator!

2.9.2 Operating, filling and displacement water lines


Water lines must be laid so that they can be completely drained at the lowest
point with no dismantling.
Y-strainers are fitted horizontally at the factory with the strainer insert pointing downwards. See section 1.3 Installation.
The solenoid valves for operating, filling and displacement water to the separator are fitted so that the hose between the separator and solenoid valves
cannot empty.

Westfalia Separator

33

2058-9601-020 / 0211

Operating, filling and displacement water


3.1
3.2
3.3
3.4
3.5

Water quality .......................................................................................... 34


Supply pressure and temperature ......................................................... 34
Water connection for operating, filling and displacement water ............ 35
Dimensions and number of consumers ................................................. 35
Water quantity ........................................................................................ 36

Westfalia Separator

34

2058-9601-020 / 0211

3.1

Water quality
The water should be as pure as possible and meet the following standards:
Hardness:
up to 55 C (131 F) separating temperature
< 12 dH
above 55 C (131 F) separating temperature
< 6 dH
Note:
When using demineralised water or condensate, corrosion must be
reckoned with.
The use of boiler feed water is not permissible!
Land water is not recommended because the degrees of hardness are
normally too high.
To convert the hardness values stated, use the following equation:
1 dH = 1,79 fH = 1,25 eH = 17,9 ppm CaCO3

pH
Chloride ions
Suspended matter
Particle size

3.2

6,5 8,5
< 100 mg/l
max. 10 mg/l
max. 50 m

Supply pressure and temperature

Fig. 30

Note:
The pressure after the water pressure reducer must not drop below 0.2 Mpa
with open operating water valve.
The supply pressure and the temperature for the operating, filling and displacement water must meet the following specifications:
Temperature

min. 10 C (50 F)
max. 85 C (185 F)

Supply pressure

0.3 1.0 MPa

Westfalia Separator

35

2058-9601-020 / 0211

3.3

Water connection for operating, filling and displacement water


Pay special attention to section 2.9.2!

3.4

Dimensions and number of consumers


Collective lines must be dimensioned so that the separators are always supplied with an adequate water volume to assure perfect functioning.
Lines must be laid so that manual override of the valves and filter replacement are possible.
The maximum length between pressure reducer and solenoid valve must not
exceed 5 m.
In the case of 1 consumer, the collective line must have the same
nominal diameter as the feed lines
to the separator.
The nominal diameter R is given in
the table below.

Fig. 31

Fig. 32

In the case of 2 consumers:


the collective line must have a nominal diameter S (see table).
the supply lines to the separator must have a nominal diameter R (see table).
Note:
When two separators request water at different times, the water supply can be
rated as for one separator.

Westfalia Separator

36

2058-9601-020 / 0211

In the case of 3 consumers:


the collective line must have a nominal diameter of DN 32.
the supply lines to the separator must have a nominal diameter R (see table).

Table for selecting the nominal diameters S and R.


Nominal diameter (DN)
Separator model
OSD 2
OSD 6
OSD 18
OSD 35
OSD 60
OSE 5
OSE 10
OSE 20
OSE 40
OSE 80

3.5

Collective line
S

Supply line
R

25
25
25
32
32
25
25
25
32
32

20
20
20
20
20
20
20
20
20
20

Water quantity
For exact program control, with simultaneous actuation of the valves, the following water quantities are required:

Separator
model

OSD 2
OSD 6
OSD 18
OSD 35
OSD 60
OSE 5
OSE 10
OSE 20
OSE 40
OSE 80

V2

V2

V3

Filling water

Displacement water

Operating
water

l/s
0,25
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1

l/s
0,25
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1

l/s
0,25
0,5
0,8
0,8
0,8
0,5
0,5
0,5
0,8
0,8

Total consumption
per cycle

Total consumption
per cycle
without
filling water

Approx. 1
2
1,5
3
2
5
3,5
10
6,5
23
13
1,6
1,1
2,3
1,5
3,2
2,0
11,6
7,6
25,4
15,4

* Ejection cycle = (filling water + displacement water + operating water)

Westfalia Separator

37

2058-9601-020 / 0211

Compressed air
4.1
4.2
4.3

Compressed air quality .......................................................................... 38


Supply pressure ..................................................................................... 38
Compressed air consumption of the separators OSD, OSE and OTC.. 38

Westfalia Separator

38

2058-9601-020 / 0211

4.1

Compressed air quality


The compressed air must be free from impurities and dry.

4.2

Supply pressure
Recommended set-up of compressed air line per treatment system.

Fig. 33

OSD separators

A supply pressure of 0.3 to max. 1.0 MPa is admissible.


After the reducer station 0.3 MPa must still be available to the consumers.
Note:
On OSD separators, a compressed air control unit is no longer included in the
standard scope of supply.
If other pneumatic components are operated, the corresponding instructions
relating to air quality and air lubrication must be observed.

4.3

Compressed air consumption of the separators OSD, OSE and OTC


The maximum compressed air consumption per separator is approx. 0.01
3
Nm /h.

Westfalia Separator

39

2058-9601-020 / 0211

Product lines
5.1
5.2
5.3
5.4
5.5
5.6
5.6.1
5.6.2
5.7
5.8
5.9
5.9.1
5.9.2
5.9.3
5.9.4
5.10
5.11

General .................................................................................................. 40
Pipe cross-sections ................................................................................ 40
Functional description ............................................................................ 40
Information on pressure monitoring ....................................................... 40
Piping ..................................................................................................... 42
Maximum suction head .......................................................................... 43
Pressure line .......................................................................................... 43
Pre-filter ................................................................................................. 44
Feed pump ............................................................................................. 44
Oil pre-heater ......................................................................................... 44
Installation examples ............................................................................. 45
Steam-heated plate heat exchanger with (PI controlled) control valve . 45
Steam-heated tubular heat exchanger with (PI controlled)
control valve ........................................................................................... 46
Thermal oil-heated plate heat exchanger with (PI controlled) control
valve....................................................................................................... 47
Thermal-oil-heated tubular heat exchanger with (PI controlled)
control valve ........................................................................................... 48
Securing plate heat exchangers ............................................................ 49
Safety valve ........................................................................................... 50

Westfalia Separator

40

2058-9601-020 / 0211

5.1

General
Pay special attention to section 1.3!
The suction lines should be as short as possible to avoid pressure losses.
The pipes must be installed with adequate clearance from the electronic
parts.
Water pockets must be avoided! (water must be able to flow off freely).
When different products are run through the same separator, it must be ensured that the corresponding product lines cannot be interchanged.

5.2

Pipe cross-sections
All pipes, valves, fittings and instruments must be laid so that an insulation of
40 mm is possible.
Dimensioning of the pipes is specified on the respective P&ID.
The pipes can be selected with the aid of the following diagram. The specifications on the P&IDs have priority!
Pipe resistances must be kept as low as possible.
Taking into account the total pressure losses, the flow velocities must be
between 0.5 m/s and < 1 m/s in suction lines,
between 1 m/s and 3 m/s in pressure lines.

5.3

Functional description
The liquid is discharged from the separator by means of a pumping device, in
the following referred to as centripetal pump. At small capacities, the discharge
can be without pressure; in the case of larger capacities the centripetal pump
generates the required pressure to convey the liquid out of the separator
through the downstream lines by immersing more deeply into the liquid.
The pressure values can differ significantly. The following rule applies: The values are lower on small separators than on large separators.
Further influencing factors are capacity, system resistances (valve position, tank
position), product properties and process specifications.

5.4

Information on pressure monitoring


When the liquid is discharged from the separator under pressure, the operator
knows that the separator bowl is hydraulically closed.
A discharge pressure adjusts given a constant capacity or it is adjusted to the
desired value by throttling in the discharge.
In the standard application, the pressure sensor responds to falling discharge
pressure, an alarm is triggered via the control system. The control system can
also evaluate rising pressure and trigger an alarm.
Generally, the discharge pressure is set to 0.1 0.2 MPa. The pressure level
can deviate from this when separator size, capacity, product properties and
process specifications require. (for further information, see the order-specific
documentation)

Westfalia Separator

41

2058-9601-020 / 0211

A change in the discharge pressure may be caused by the following factors:


Change in feed capacity
Change in product data such as temperature, density, viscosity
Change in discharge resistance
Leakage at the separator bowl
This represents important information for the operator.

Selection diagram

Fig. 34

Q
v

Flow
Velocity in m/s

Example:
3

A flow rate of 5 m /h produces a velocity of 1.2 m/s with a nominal diameter of


40.

Westfalia Separator

42

2058-9601-020 / 0211

5.5

Piping

Fig. 35

Lubrication oil schematic

1 LO tank
When separating lube oil, the return line of the 3/2-way valve can be led into
the product discharge line of the separator.

Fig. 36

Diesel oil schematic

1 DO tank
2 Service tank
When separating diesel oil, the return line of the 3/2-way valve must be led
into the DO tank 1.
WS does not permit leading the return line into the suction side of the
pump!

Westfalia Separator

43

2058-9601-020 / 0211

Fig. 37

Heavy fuel oil schematic

1 Settling tank
2 Service tank
When separating heavy oil, the return line of the 3/2-way valve must be led
into the settling tank 1.

5.6

Maximum suction head


The suction head of the feed pump (gear pump) is max. 0.04 Mpa.
The suction head of the feed pump (screw pump) is max. 0.05 MPa.
The viscosity of the oil to be conveyed must be kept < 1 000 cSt, if necessary
by adequate pre-heating and trace heating.
When dimensioning the suction line, it must be ensured that the total pressure
loss in the pipe does not exceed the maximum suction head of the pump.
The maximum feed pressure in the suction line must not exceed 0.05 MPa.

5.6.1 Pressure line


The pressure head of the feed pump is set to approx. 0.3 MPa.
The pressure line from the feed pump via the pre-set valve, the pre-heater
and the 3/2-way valve to the separator must be kept as short as possible.
When dimensioning the pressure line, it must be ensured that the total pressure loss in the pipes does not exceed the maximum pressure head of the
pump.

Westfalia Separator

44

2058-9601-020 / 0211

5.6.2 Pre-filter
The pre-filters are fitted in the suction line of the feed pump to protect it from
coarse impurities.
During the installation, special attention must be paid to the operability.
Use only strainers with a mesh width
of the strainer insert of 1 to 1.25
mm.
Pay special attention to section 1.3!

Fig. 38

Use only pre-strainers with a mesh


width of the strainer insert of 0.63
mm.

Fig. 39

5.7

Feed pump
To prevent the pre-heater from overheating,
a pump post-running time must be programmed for pump units and product
pre-heating.

5.8

Oil pre-heater
It must be installed so that there is no heat dissipation to the control cabinet.
To prevent a risk of accidents when venting due to discharging hot vapours and liquids,
the discharge lines from vent valves must be laid at least to floor plate height.
Discharge lines of safety valves must be laid so that there is no danger
of accident when the valve responds due to discharging liquid.
The discharge line must be laid so that it can always be observed. It must not
be concealed by pipes, valves or other units!

Westfalia Separator

45

2058-9601-020 / 0211

Steam traps
must be fitted horizontally between two unions.
should not be insulated to assure correct functioning.
must be installed so that no condensate accumulation can occur on the preheaters.

5.9

Installation examples
The following sections show installation examples for
Tubular heat exchanger
Steam-heated plate heat exchanger with (PI controlled) control valve
Steam-heated tubular heat exchanger with (PI controlled) control valve
Thermal oil-heated plate heat exchanger with (PI controlled) control valve
Thermal-oil-heated tubular heat exchanger with (PI controlled) control valve

5.9.1 Steam-heated plate heat exchanger with (PI controlled) control


valve

Fig. 40

A
B
C
D

Oil inlet
Oil outlet
Steam inlet
Condensate outlet

0.1
1.0
1.1
2.1
2.2
2.3

Spring safety valve


Plate heat exchanger
Resistance thermometer (PT 100)
Strainer
Motor control valve
Ball float condensate trap

Westfalia Separator

46

2058-9601-020 / 0211

5.9.2 Steam-heated tubular heat exchanger with (PI controlled) control


valve

Fig. 41

A
B
C
D

Oil inlet
Oil outlet
Steam inlet
Condensate outlet

0.1
1.0
1.1
2.1
2.2
2.3

Spring safety valve


Tubular heat exchanger
Resistance thermometer (PT 100)
Strainer
Motor control valve
Ball float condensate trap

Westfalia Separator

47

2058-9601-020 / 0211

5.9.3 Thermal oil-heated plate heat exchanger with (PI controlled) control
valve

Fig. 42

A
B
C
D

Oil inlet
Oil outlet
Thermal oil inlet
Thermal oil outlet

0.1
1.0
1.1
2.1

Spring safety valve


Plate heat exchanger
Resistance thermometer (PT 100)
Motor control valve

Westfalia Separator

48

2058-9601-020 / 0211

5.9.4 Thermal-oil-heated tubular heat exchanger with (PI controlled)


control valve

Fig. 43

A
B
C
D

Oil inlet
Oil outlet
Thermal oil inlet
Thermal oil outlet

0.1
1.0
1.1
2.1

Spring safety valve


Tubular heat exchanger
Resistance thermometer (PT 100)
Motor control valve

Westfalia Separator

49

2058-9601-020 / 0211

5.10

Securing plate heat exchangers


Assembly instructions for soldered
plate heat exchanger
Prepare an assembly plate support
and weld it to the foundation.
Fasten assembly plate 50 with
screws 70 and nuts 80 to the assembly plate support.
The assembly plate must be installed vertically relative to the pipe
axis.
IMPORTANT:
Welding the assembly plate to the
support is not permitted.
Fasten heat exchanger with gaskets
40 counterflanges 30, lock washers
20 and screws 10 to the assembly
plate.
Attach the pipes to the counterflanges by tack-welding.
Dismantle the heat exchanger and
gaskets.
Completely weld the pipes to the
counterflanges.
Finally, re-assemble the parts as per
instruction.
Fig. 44

A
B

The illustrated channel steel must be provided by the shipyard.


GEA Westfalia Separator recommendation as example channel steel according to DIN1026-1-50.

IMPORTANT:
Distortion or warping or other stress of the soldered connection points must be
avoided!
Pipelines must be correspondingly arrested.
Pos./
type

10

20

30

40

50

70

80

Allen screw

Lock
washer

Groovefaced
flange

Gasket

Plate

Hex head
screw

Hexagon
nut

B 10

ISO 4762 M10 x 45


(16 x)

DIN127 B10
(16 x)

1 in SAE3000P
SI
(4 x)

32.92 x 3.53
(8 x)

352 x 125 x
12
(1 x)

ISO 4017 M12 x 40


(2 x)

ISO 3032 M12


(2 x)

B 45

ISO 4762 M12 x 55


(16 x)

DIN127 B12
(16 x)

2 in SAE3000P
SI
(4 x)

56.74 x 3.53
(8 x)

563 x 290 x
12
(1 x)

ISO 4017 M12 x 40


(2 x)

ISO 3032 M12


(2 x)

Westfalia Separator

50

2058-9601-020 / 0211

5.11

Safety valve
Safety valve in vertical fitting position

Fig. 45

The safety valve outlet should be led


via a funnel (pos. 1).
A discharge line is welded to the
funnel via which the medium can be
discharged.
IMPORTANT:
Do not use galvanized components and hoses.

Fig. 46

Westfalia Separator

51

2058-9601-020 / 0211

Solids tank
6.1
6.1.1
6.1.2
6.2
6.2.1
6.2.2
6.2.3
6.3
6.3.1

Recommended criteria for solids tank ................................................... 52


Tank vent ............................................................................................... 53
Set-up of the solids tank venting ........................................................... 54
Solids discharge lines ............................................................................ 55
Solids discharge lines with shut-off flap................................................. 56
Standard installation of shut-off flaps .................................................... 56
Installation recommendation for shut-off flaps ....................................... 57
Operating and dirty water discharge lines ............................................. 58
Separators of OSD and OSE ................................................................. 58

Westfalia Separator

52

2058-9601-020 / 0211

6.1

Recommended criteria for solids tank


Note:
This information does not apply to sludge transfer units on compact units.
There should always be separate solids tanks for the lube oil and fuel systems.
Tank heating should be installed in dependence of the viscosity or ambient
temperature.
The general designs and constructions are subject to the valid regulations.
1
2
3
4

Monitoring
Venting
Tank heating
Utilizable volume

Fig. 47

Minimum solids tank volume


Separator model
OSD 2
OSD 6
OSD 18
OSD 35
OSD 60
OSE 5
OSE 10
OSE 20
OSE 40
OSE 80

Volume
[l]

Maximum utilizable volume


[%]

80
200
200
300
300
80
200
200
300
300

60
60
60
60
60
60
60
60
60
60

Westfalia Separator

53

2058-9601-020 / 0211

6.1.1 Tank vent


In the case of one or more separators which are connected to a solids tank,
the nominal widths DN to be used are given in the table below:
Note:
Connect the tank vent to the on-board venting system.
Separators
per solids tank
1
2
3

1
2
3

OSD 2
50
50
80

OSD 6
80
100
125

OSE 5
50
50
80

OSE 10
80
100
125

Tank vent
DN in mm
OSD 18 OSD 35
80
125
100
150
125
150
OSE 20
80
100
125

OSE 40
125
150
150

OSD 60
125
150
150
OSE 80
125
150
150

In the case of a combination of separator models on one solids tank


the total number of all separators must be taken as a basis
and the nominal width of the largest model used.
The following criteria must be taken into consideration when venting the tank:
Installation in accordance with the guidelines of the classification societies
Controlled discharge of oil vapours
An uncontrolled discharge of the sludge must be avoided.
The vent lines must be laid so that a chimney effect develops.
All possible loops in the vent lines must be stepwise.

Westfalia Separator

54

2058-9601-020 / 0211

6.1.2 Set-up of the solids tank venting


Solids tank with one separator
The nominal width DN is given in the
table above (section 6.1.1).

Fig. 48

Solids tank with several separators


The nominal width DN is given in the
table above (section 6.1.1).

Fig. 49

Solids tank with wash plates


A solids tank with wash plates is required when movements of the ship
cause faulty functioning of the level
monitoring.
When using wash plates, each section must be vented.
The vent lines must be brought together.

Fig. 50

Westfalia Separator

55

2058-9601-020 / 0211

6.2

Solids discharge lines

Fig. 51

The solids discharge lines should


always be vertical if possible.
The solids discharge must always
end 50 100 mm below the tank
top.
The maximum level in the solids
tank must be monitored by means of
a float switch.
The piping for the solids discharge
should be without reduction and with
vibration compensators.
The length of 2 m may not be exceeded without trace heating.
If there is a deviation from the vertical, an angle of 45 must not be exceeded.

Fig. 52

IMPORTANT:
This piping arrangement is not admissible!

Fig. 53

Westfalia Separator

56

2058-9601-020 / 0211

6.2.1 Solids discharge lines with shut-off flap


A shut-off flap in the solids discharge line prevents the penetration of vapours
into a stationary separator during the desludging of another separator.
If more than one separator is used for a sludge tank, a shut-off flap must be
installed in the sludge discharge at the shipyard.
Shut-off flaps are not included in the standard scope of supply of GEA Westfalia Separator but can be ordered from GEA Westfalia Separator.
CP units or modules equipped with a sludge tank supplied by GEA Westfalia
Separator and equipped with more than one separator are always delivered
with shut-off flaps.

6.2.2 Standard installation of shut-off flaps


Separators of OSD and OSE

Fig. 54

I
II

Solids discharge
Hood and frame drain

III
IV

Tank vent
Shut-off flap

Discharges I, and III must be configured as illustrated in Fig. 57.


See section 6.1.1, table for tank vent connection.
ATTENTION!
It must be ensured that the shut-off flaps are open during separator operation.

Westfalia Separator

57

2058-9601-020 / 0211

6.2.3 Installation recommendation for shut-off flaps


The solids discharge must always
end below the tank top.
For dimension X, see section 6.2,
Fig. 51.

I
II
III
IV
V

Shut-off flap
Flange
Pipe
Hose (supplied with separator)
Solids tank cover

Fig. 55

Fig. 56

Westfalia Separator

58

2058-9601-020 / 0211

6.3

Operating and dirty water discharge lines


The discharges for operating and dirty water can be conveyed into a separate
tank for oily water.
The piping for the operating and dirty water discharge should be vertical,
without reduction and with vibration compensators. There is no upper length
limit.
IMPORTANT:
Operating and dirty water discharges may not be discharged into public
canals, draining ditches and waters!

6.3.1 Separators of OSD, OSE and OTC


The water discharges must be submerged
under
all
conditions
(roll/pitch).
Dimension h is:
min. 50 mm for shipboard operation,
min. 20 mm for stationary plants.
I
II
III

Hood and frame drain


Solids discharge
Tank vent

Fig. 57

When a siphon is installed, the


frame drain need not be submerged
below the minimum level because a
liquid seal is assured.
Dimension h1 is given in the table
below.
I
II
III
IV

Solids discharge
Hood and frame drain
Tank vent
Siphon for hood and
frame drain

Fig. 58

Westfalia Separator

59

2058-9601-020 / 0211

Table for defining siphon length, dimension h1


Separator model
OSD 6 / OSD 18
OSD 35 / OSD 60
OSE 5
OSE 10
OSE 20
OSE 40
OSE 80
OTC 2
OTC 3
OTC 5
OTC 10
OTC 20

Siphon length [mm]


h1
500
800
500
500
500
800
800

Westfalia Separator

60

2058-9601-020 / 0211

Note
Notes
Notizen
Anotaciones

Muistiinpanot

Notater
Notes
Note

Westfalia Separator

61

2058-9601-020 / 0211

Electrical installation
7.1
7.1.1
7.1.2
7.1.3
7.1.4
7.2
7.3
7.3.1
7.3.2
7.3.3
7.4
7.5
7.6
7.6.1
7.6.2
7.6.3
7.6.4
7.6.5
7.7
7.8

Control cabinet ....................................................................................... 62


Electrical connection .............................................................................. 64
External voltages ................................................................................... 64
Shipboard operation .............................................................................. 65
Onshore operation ................................................................................. 65
Electro-magnetically compatible installation .......................................... 66
Valves .................................................................................................... 67
Solenoid valve block .............................................................................. 67
Terminal box .......................................................................................... 68
Separator with sensor bloc .................................................................... 69
Dual-purpose thermometer .................................................................... 70
Electrical installation of transmitters and electric motors ....................... 71
Electrical execution ................................................................................ 71
Earthing the separator ........................................................................... 72
Voltage equalisation of the separator .................................................... 72
Voltage equalization of the electric heater ............................................. 73
Voltage equalization of the foundation frame ........................................ 73
Voltage equalisation of the control cabinet ............................................ 74
Electric motors procured by the customer ............................................. 75
Installation and operation of control units .............................................. 76

Westfalia Separator

62

2058-9601-020 / 0211

7.1

Control cabinet
Control cabinet configuration

Fig. 59

Fig. 60

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Lock

Control Unit D10

OFF/ON keys for separator

OFF/ON keys for feed pump

HAND/0/AUTOMATIC selector for


solids pump (option)

Main switch

Front view

Interior view

Isolating amplifier for analog output (option)


WMS (Water Content Monitoring System) relay, if provided
Full-motor-protection module
Interface relay
Auxiliary contactor
Main contactor
Current transformer
Power supply for PLC (Programmable Logic Control) and valves
Terminal Strip
Control transformer for heating and venting facilities (option)
Main switch
Control voltage transformer (option)
Motor protection switch
Safety outcut

Westfalia Separator

63

2058-9601-020 / 0211

Mounting example
1
2
3
4
5
6

Gasket 10,5x23x5
Threaded bolt M 8 (embedded
in the wall)
Washer
Rear panel of control cabinet
Washer
Wall

Fig. 61

The control cabinet


must be allocated to the corresponding separator by means of its designation.
must be mounted on a frame or wall in the vicinity of the separator.
conforms to enclosure IP 54.
It must be possible to open the control cabinet door wide so that the door
latch can lock into place.
Select the installation site so that
it can be easily operated and observed.
an ambient temperature of 50 C (122 F) is not exceeded. If necessary,
make sure there is an adequate supply of fresh air.
If the control cabinet is mounted on a wall, a wall clearance of 20 m must be
observed to achieve a vibration-free fastening arrangement.
Although buttons and switches and the electronic control unit are protected
against moisture by protective foil and door seal, the cabinet must nevertheless not be installed in an excessively humid environment or damp area.
To keep the temperature inside the unit constant after commissioning, the
main switch should be kept turned on even when the separator is at a standstill.

Westfalia Separator

64

2058-9601-020 / 0211

7.1.1 Electrical connection


The control unit is designed for a connected voltage as indicated on the
nameplate inside the control cabinet.
In the case of a version without motor starter, the rated connection voltage is
115 VAC or 230 VAC which must be protected by a 6 A slow-blow fuse.

7.1.2 External voltages


carry external voltage (even when the main switch is off!).
can be identified by the orange coloured wiring.
can be used in external control systems up to 250 VAC.
2

A cross-section of 1.5 mm Cu is adequate for all control and interlocking


lines.
The voltage-free contacts of the output modules

Westfalia Separator

65

2058-9601-020 / 0211

7.1.3 Shipboard operation


For shipboard operation
Only lines type "MGCH" according to DIN 89 158 may be used.
All cables must meet the flame test requirements for bunched cables acc.
to IEC 60332-3 / IEEE 45-18.13.
All cable materials must be free of halogens acc. to IEC 60754-1, no
toxicity acc. to 60754 and no corrosivity acc. to IEC 60754-2.
All cables must have an approval of the relevant classification society.
Insulating strength: 0.6/1KV
GEA WSPN Standard: Nexans MPRX 0.6/1kV
The standard control cabinets are equipped with plastic non halogen oil
resident. WS standart is Ernst Heinrich GmbH
load and control lines can be laid jointly without clearance
In the case of HFO separators in series operation, the signal exchange between the control cabinets as per the terminal diagram for the connecting cable must be taken into account (see section 7.2).

Cable glands for shipboard installation


Female
thread
M 16 x 1.5
M 20 x 1.5
M 25 x 1.5
M 32 x 1.5
M 40 x 1.5

Cable outer
Cable gland
[mm]
4 11
8 13
11 17
15 21
19 28

Earthing device +
Inner parts design

M 24 x 1.5
M 24 x 1.5
M 36 x 1.5
M 36 x 1.5
M 36 x 1.5

7.1.4 Onshore operation


The local rules and regulations of the operator must be observed!
for onshore operation
Normally, "lflex" cables are used and "NSSHU" for outside installation.
commercially available cable glands can be used.
separate cable routing must be used for the load and control lines.
Cable entries with plastic or metal glands are admissible.

Westfalia Separator

66

2058-9601-020 / 0211

7.2

Electro-magnetically compatible installation


The control cabinet is designed to be electro-magnetically compatible.
The following must be taken into account with electro-magnetically compatible
installations:
Earthing straps
Voltage equalization
Screening lines
Separate line routing
Use of erase elements in case of inductance.
In the case of HFO series operation, proceed in accordance with the following
wiring diagram:

Fig. 62

A Switch ON
B Control cabinet HFO No. 1
C Control cabinet HFO No. 2

D Connecting terminals
F Cable type
E Customer shipboard installation

IMPORTANT:
Use only data cable UNITRONIC-BUS-FD P L2/F.I.P (1 x 2 x 0.25 mm +
Screen).
Do not lay data cables directly next to load cables as this can cause problems with electromagnetic compatibility.
Pay attention to the different software status on the C7 units:
1. unit has the MPI addresses 1 / 2
2. unit has the MPI addresses 3 / 4
3. unit has the MPI addresses 5 / 6
Faulty or broken cable connections are displayed with error code no. 551.
Check all connections.

Westfalia Separator

67

2058-9601-020 / 0211

7.3

Valves
Only original valves from GEA Westfalia Separator with integrated suppressor
diode and reverse battery protection in the connection head may be used in
filling, displacement and operating water lines.

7.3.1 Solenoid valve block


This diagram shows an original valve
block from GEA Westfalia Separator
which is used in filling, displacement
and operating water lines.

Fig. 63

Connections
A
B
C
D

Connecting terminal + 24 V DC
Connecting terminal + 0 V DC
Earth
Status LED

Fig. 64

Westfalia Separator

68

2058-9601-020 / 0211

7.3.2 Terminal box


All valves and monitoring instruments
are installed ready-to-connect on a
local terminal box at the separator.
The connection to the control cabinet must be carried out by means of
a joint cable in accordance with the
adjacent connection diagram.

A
B
C
D
E
F
G
H
I
J
K

Control cabinet
Product discharge pressure
Self-Think system
Water sensor
Circuit valve
Water discharge valve
Filling, displacement water valve
Operating water valve
Circulation valve
Operating Water
Filling, displacement water

Fig. 65

Westfalia Separator

69

2058-9601-020 / 0211

7.3.3 Separator with sensor bloc

Fig. 66

The components on the hood are wired to the terminal box.

Westfalia Separator

70

2058-9601-020 / 0211

7.4

Dual-purpose thermometer
The dual-purpose thermometer is used
to monitor the temperature of the dirty oil after the pre-heater and
for local temperature indication.
ATTENTION!
The dual-purpose thermometer is used only in conjunction with a C7 control
system.

Fig. 67

Fig. 68

The dual-purpose thermometer must always be fitted before the 3-way piston
control valve.
All sensors must be installed so that they are continuously flushed with oil.

Westfalia Separator

71

2058-9601-020 / 0211

7.5

Electrical installation of transmitters and electric motors


The connection of motors and transmitters by means of cable loop enables
easy replacement and function testing of the components.
Example 1

Fig. 69

Example 2

Fig. 70

7.6

Electrical execution
The electrical execution must be in accordance with the following standards and
recommendations in so far as specifications and standards issued by the classification societies do not have to be met.
The applicable standards at GEA Westfalia Separator are
the European standard EN 60 204 Part 1 or
VDE 0113 Part 1

Westfalia Separator

72

2058-9601-020 / 0211

7.6.1 Earthing the separator


The separator
earthed.

must

always

be

The earthing connection A is always


located on the motor side beneath the
motor flange.

Fig. 71

7.6.2 Voltage equalisation of the separator


Including the insulated installed separator in the voltage equalisation of the
installation is done via the voltage
equalisation connection on the motor
side. This applies always.

Fig. 72

If there is no protective conductor in


multi-core cables and leads (e.g. in the
armoured marine cable), the drive
motor must likewise be included in the
voltage equalisation.
The same applies for pump motors
and electric pre-heaters.
The cross-section of the voltage
equalisation conductor, normally insulated green-yellow, is dimensioned to
the largest external conductor on the
respective consumer.
In practice, table 1 in EN 60204-1 is
used for this.
GEA Westfalia Separator selects:
2
2
10 mm < S < 25 mm Cu

Fig. 73

Westfalia Separator

73

2058-9601-020 / 0211

7.6.3 Voltage equalization of the electric heater

Fig. 74

7.6.4 Voltage equalization of the foundation frame


The foundation frame must be fitted
with a marked connecting bolt for
voltage equalisation by the customer.

Fig. 75

Fig. 76

Westfalia Separator

74

2058-9601-020 / 0211

7.6.5 Voltage equalisation of the control cabinet


The connection is via the PE-bar or terminal inside the cabinet to the frame
connection.
PE connection

Fig. 77

PE connection

Fig. 78

PE connection

Fig. 79

Westfalia Separator

75

2058-9601-020 / 0211

7.7

Electric motors procured by the customer


When the motors are procured by the customer, they must have the following
specifications and comply with the following standards:
Design

IM B5* according to IEC 34 Part 7

Rating

Classification according to IEC 72 Part 2

Enclosure

IM B5 according to IEC 34 Part 5

Vibration severity
Synchronous speed

Quality stage N * / S *according to IEC 34 Part


14,
Full key balanced * / Half key balanced *
50 Hz
60 Hz
3000 * / 1500 *
3600 * / 1800 *

Type of cooling

1C411 according to IEC 34 Part 6

Flange dimensions

according to IEC 72

Shaft dimensions

according to IEC 72

Direction of rotation

according to IEC 34 Part 8

Insulation material class

F according to IEC 34 Part 1


PTC thermistors as full motor protection

Motor protection

Operating mode

The PTC resistors mist be fitted in the end


windings one per strand.
PTC resistors temperature feelers which are
mounted on the winding package from the
outside are not acceptable!
SI according to IEC 34 Part 1

* dependent on separator model

ATTENTION!
Consequential damage on the separator caused by motors procured by
the customer cannot be accepted as a warranty claim by GEA Westfalia
Separator.

Westfalia Separator

76

2058-9601-020 / 0211

7.8

Installation and operation of control units


IMPORTANT:
Outdoor exposure is not admissible!
Select the installation site so that
the control unit is not exposed to dust and aggressive atmosphere.
the control unit is not installed in an excessively humid environment or
damp area.
the sun cannot shine on the control panel or displays making operation and
observation more difficult.
heating up of the control unit is avoided.
Where appropriate, check screw-type and plug-type connectors for secure
contact.
Connect thermostatically controlled cabinet heating to external voltage and
switch it on.
The control cabinet heating must switch on before the temperature drops below the dew point.
Bedewing can occur during the night which is not good for electronic apparatus.
Check that the line voltage and frequency conform to the connection data of
the control unit (see nameplate).
Pay attention to admissible installation and operating data:
Voltage fluctuations
Frequency fluctuations
Ambient temperatures
Atmospheric humidity
Installation height
Transport temperatures

+/- 10 % of the line voltage


+/- 2 % of the line voltage
+ 5 to + 45 C (41 to 113 F)
max. 50 % at 40 C (104 F)
max. 90 % at 20 C (68 F)
above sea level up to 1000 m
25 to + 55 C (13 to 131 F)

ATTENTION!
Improper installation and operation discharges the supplier from the warranty obligation.

Westfalia Separator

77

2058-9601-020 / 0211

Note
Notes
Notizen
Anotaciones

Muistiinpanot

Notater
Notes
Note

Westfalia Separator

78

2058-9601-020 / 0211

Note
Notes
Notizen
Anotaciones

Muistiinpanot

Notater
Notes
Note

Westfalia Separator

2058-9601-020 / 0211

79

Westfalia Separator

GEA Mechanical Equipment

GEA Westfalia Separator Group GmbH


Werner-Habig-Str. 1, 59302 Oelde (Germany)
Phone +49 2522 77-0, Fax +49 2522 77-2488
ws.info@geagroup.com, www.westfalia-separator.com

Contents
2.

HFO
Data sheet
P&ID
Equipment list
Dimensioned drawing
Detail drawings:

2063-4100-000

3/2-Way feed valve

9901-8105-390

Dimensioned drawing for motor

9901-8105-305

Starting characteristics

9997-0142-020

Circuit diagram

8106-2004-058

Commissioning equipment, spare parts and tools list

GEA Westfalia Separator Systems GmbH

Process Condition Data Sheet


Manufacurer:
Customer:
Hull No.:
Classification:

DSME
43223
44608
ABS

Project No.:

Oil to be Processed
Application:
Viscosity:
Density:
Inlet Temperature:
Separating Temperature:
Effec.throughput capacity:
Ambient Conditions
Ambient Temperature:
Humidity:
Atmospheric Pressure:
Separator
Type:
Operation Mode:
Ejection Method:
Clean Oil Discharge:
Finish color:
Total weight:
Bowl speed
Bowl weight
Control Unit
Type:
Infeed voltage:
Frequency:
Valve Voltage:
Control Voltage:
Finish Color:
Weight:

Rev. No. 0

HFO

H1195
H1196

600
1,01
60
98
4.500

mm /s 50C
g/ml 15C
C
C
l/h

IMO No.:

WS Order No:

Drawing No.:

P452946646-9913-PDS000

Operating Water
Hardness:
Chloride Ions:
PH - Value:
Temperature:
Feed Pressure:
Required Capacity:
Consumption / Ejection:

45 C

up to 92%
up to 1000 m Above Sea Level
2 x OSE 40-0136-067/30
total
1,5
Munsell 7.5 BG 7/2
1600
8200
255
D 10
440
60
24
230
Munsell 7.5 BG 7/2
55

bar g
kg
rpm
kg
Volt
Hz
DC
Volt
kg

< 55C 12 dH
> 55C 6 dH
< 100 mg/l
6,5 - 7,5
+10C up to +85C
3-10 bar (min.3bar)
0,5 l/s
3-4 l

Compressed Air
Pressure:
7
Standard operating compressed air
Min. 3 bar / max. 10 bar
Separator Motor
Type:
Frame size 160
Voltage:
440
Frequency:
60
Output:
17,5
Speed:
3600
Weight:
107
Feed Pump
Type:
Rated Capacity:
Suction Height:
Delivery Height:
Voltage:
Frequency:
Output:
Weight:
Set Points

bar

Volt
Hz
kW
rpm
kg

l/h
m Ws
m Ws
440 Volt
60 Hz
kW
kg

Adjustment
Inlet Temperature Controler TC

ID No.
*0-9-007

Inlet Temperature Alarm high TAH

*0-9-006

108 C

Inlet Temperature Alarm low TAL

*0-9-006

88 C

Water Pressure Reducer PCV

*9-7-003

3 -10 bar g

Pressure Alarm low PAL Clean Oil Discharge

*1-9-002

1 bar

Pressure Switch PSL Sludge Monitoring System

*1-9-003

1 bar for -91-/0136 0,5 bar for -0196-

Subject to technical modification

452946646
452946721

98 C

12.10.2010

Customer: DSME

Project-/Order-No.:

43223 / 402946646

Location:

Project-title:

2XOSE 40-0136

H1195/H1196

GEA Westfalia Separator

Equipment List

Order-No.:

402946646

Project - title:

2XOSE 40-0136

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Date: 12.10.2010

Dept.: 4420

Type: OSE 40

Corr. Drawing: P402946646-9913-PID000

Belongs to:

Repl for: ---

Repl. by: ---

Std. checked: ---

Explanations:
Priority(A):

Procurement (B):

Scope of supply (C):

N = Obligatory
E = Recommended
P = Possible
U = ---

M = Must be obtained from Westfalia


K = May be obtained from Westfalia
Z = Supplied by client
V = ---

L = Scope of supply by WS
S = Supplied by client
F = to be removed
W = loose supply

Created Date: 04.10.2010

Checked Date:

Approved Date:

Document No.:

By:

By:

By:

P402946646-9913-DVL000

4110-NIE

Copyright. All rights reserved

Revison:

Page:
1/5

Customer: DSME

Project-/Order-No.:

43223 / 402946646

Location:

Project-title:

2XOSE 40-0136

H1195/H1196

GEA Westfalia Separator

Equipment List
ID

Quantity

Description
Usage

Size/Type
Nominal Bore

10-1-001

1 Stck

Separator

10-1-001/M1

1 Stck

Motor

10-7-005

1 Stck

Throttle Valve

Power

Part-No.

OSE 40-0136-067

Frame size 160

belongs to 10-7-006

0018-8091-110

Comments
PID Code

DN50
10-7-006

1 Stck

3/2-Way Feed Valve Assembly


DN50

10-7-010

1 Stck

2/2 Way Solenoid Valve

0331

0018-8133-600

10-7-011

1 Stck

2/2 Way Solenoid Valve

0331

0018-8133-600

10-7-012

1 Stck

Pressure Gauge Cock

belongs to 10-1-001

TE

belongs to 10-7-006

1/4"
10-9-006

1 Stck

Resistance Thermometer

10-9-009

1 Stck

Flow Sensor

FI

0001-1701-600

10-9-010

1 Stck

Resistance Thermometer

TE

installed in Motor

10-9-011

1 Stck

Current Transformer

TAI 233

IAL

0005-0924-220

10-9-013

1 Stck

Water Detector

SK1-HT125-HFO

CS

0005-1464-050

10-9-014

1 Stck

Pressure Transmitter

NAE
1/4"

PT

0005-1529-300

10-9-018

1 Stck

Proximity sensor

SIS

0005-0868-000

11-7-001

1 Stck

Non-Return Valve

0018-2992-650

2 x PT 100
1/2"

1 1/2"

Created Date: 04.10.2010

Checked Date:

Approved Date:

Document No.:

By:

By:

By:

P402946646-9913-DVL000

4110-NIE

Copyright. All rights reserved

Revison:

Page:
2/5

Customer: DSME

Project-/Order-No.:

43223 / 402946646

Location:

Project-title:

2XOSE 40-0136

H1195/H1196

GEA Westfalia Separator

Equipment List
ID

Quantity

Description
Usage

11-7-003

1 Stck

Pressure Gauge Cock

Size/Type
Nominal Bore

Power

Part-No.

belongs to 10-1-001

Comments
PID Code

1/4"
11-9-001

1 Stck

Pressure Gauge

213.40 / 0..40bar
1/4"

PI

0001-1572-600

11-9-002

1 Stck

Pressure Transmitter

NAE
1/4"

PT

0005-1529-300

12-7-001

1 Stck

Non-Return Flap

belongs to 10-7-006

belongs to 10-7-006

0018-1763-630/belongs
to 19-7-003

0018-7614-000

belongs to 19-7-003

belongs to 19-7-004

belongs to 19-7-005

0001-1572-600/belongs
to 19-7-003

L
L

DN 50
18-7-002

1 Stck

Solenoid Valve
1/4"

19-7-002

1 Stck

Ball Valve
3/4"

19-7-003

1 Stck

Solenoid Valve Assembly compl.


3/4"

19-7-004

1 Stck

2/2-Way Solenoid Valve


1/2"

19-7-005

1 Stck

2/2-Way Solenoid Valve


1/4"

19-8-001

1 Stck

Y-Strainer
3/4"

19-9-001

1 Stck

Pressure Gauge

213.40 / 0..10bar

PI

20-1-001

1 Stck

Separator

OSE 40-0136-067

20-1-001/M1

1 Stck

Motor

Frame size 160

20-7-005

1 Stck

Throttle Valve

belongs to 10-7-006

0018-8091-110

DN50
20-7-006

1 Stck

3/2-Way Feed Valve Assembly


DN50

Created Date: 04.10.2010

Checked Date:

Approved Date:

Document No.:

By:

By:

By:

P402946646-9913-DVL000

4110-NIE

Copyright. All rights reserved

Revison:

Page:
3/5

Customer: DSME

Project-/Order-No.:

43223 / 402946646

Location:

Project-title:

2XOSE 40-0136

H1195/H1196

GEA Westfalia Separator

Equipment List
ID

Quantity

Description
Usage

Size/Type
Nominal Bore

20-7-010

1 Stck

2/2 Way Solenoid Valve

20-7-011

1 Stck

2/2 Way Solenoid Valve

20-7-012

1 Stck

Pressure Gauge Cock

Power

Part-No.

0331

0018-8133-600

0331

0018-8133-600

belongs to 10-1-001

TE

belongs to 10-7-006

Comments
PID Code

1/4"
20-9-006

1 Stck

Resistance Thermometer

20-9-009

1 Stck

Flow Sensor

FI

0001-1701-600

20-9-010

1 Stck

Resistance Thermometer

TE

installed in Motor

20-9-011

1 Stck

Current Transformer

TAI 233

IAL

0005-0924-220

20-9-013

1 Stck

Water Detector

SK1-HT125-HFO

CS

0005-1464-050

20-9-014

1 Stck

Pressure Transmitter

NAE
1/4"

PT

0005-1529-300

20-9-018

1 Stck

Proximity sensor

SIS

0005-0868-000

21-7-001

1 Stck

Non-Return Valve

0018-2992-650

belongs to 10-1-001

2 x PT 100
1/2"

1 1/2"
21-7-003

1 Stck

Pressure Gauge Cock


1/4"

21-9-001

1 Stck

Pressure Gauge

213.40 / 0..40bar
1/4"

PI

0001-1572-600

21-9-002

1 Stck

Pressure Transmitter

NAE
1/4"

PT

0005-1529-300

22-7-001

1 Stck

Non-Return Flap

belongs to 10-7-006

DN 50

Created Date: 04.10.2010

Checked Date:

Approved Date:

Document No.:

By:

By:

By:

P402946646-9913-DVL000

4110-NIE

Copyright. All rights reserved

Revison:

Page:
4/5

Customer: DSME

Project-/Order-No.:

43223 / 402946646

Location:

Project-title:

2XOSE 40-0136

H1195/H1196

GEA Westfalia Separator

Equipment List
ID

Quantity

Description
Usage

28-7-002

1 Stck

Solenoid Valve

Size/Type
Nominal Bore

Power

Part-No.

belongs to 10-7-006

0018-1763-630/belongs
to 19-7-003

0018-7614-000

belongs to 19-7-003

belongs to 19-7-004

belongs to 19-7-005

0001-1572-600/belongs
to 19-7-003

Comments
PID Code

1/4"
29-7-002

1 Stck

Ball Valve
3/4"

29-7-003

1 Stck

Solenoid Valve Assembly compl.


3/4"

29-7-004

1 Stck

2/2-Way Solenoid Valve


1/2"

29-7-005

1 Stck

2/2-Way Solenoid Valve


1/4"

29-8-001

1 Stck

Y-Strainer
3/4"

29-9-001

1 Stck

Pressure Gauge

213.40 / 0..10bar

PI

Created Date: 04.10.2010

Checked Date:

Approved Date:

Document No.:

By:

By:

By:

P402946646-9913-DVL000

4110-NIE

Copyright. All rights reserved

Revison:

Page:
5/5

GEA Westfalia Separator


Werner-Habig-Str. 1 - 59302 Oelde ( Germany ) - Phone +49 2522 77-0

Kunde
Customer

: -

Anlagenbezeichnung
Designation of plant

: -

Zeichnungsnummer
Drawing no.

: 8106-2004-058

Kommission
Internal order no.

: -

Hersteller (Firma)
Manufacturer (Company)

: GEA Westfalia Separator

Projektname
Name of project

: -

Typ
Type

: D10 / OSE 40-0136

Sprache
Language

: de/en

Technische Daten
Technical data

: 230V AC

Erstellt am
Prepared

: 07.10.2010

GEA Projektsachbearbeiter : M. Kalb


GEA project contact
Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

60 Hz

Bearbeitet am
Processed

: 04.03.2011

Telefon
Telephone

: +49 2522 77-2802

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

+/-5 %

Benennung/Description:

Titel- / Deckblatt
Title- / cover sheet

Angewandte Normen:
Applied standards:

Rev.01 =
As built +

Sprache:
Language:

IEC 61346
IEC 61355
IEC 60617

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EAA

Bl./Sh.
1
67 Bl./Sh.

Inhaltsverzeichnis
Table of contents
Dokumentenart
Document type

Seite
Page

Date

Anlage
Plant

Einbauort
Mounting place

Datum
Date

Bearbeiter
Editor

&EAA

Titel- / Deckblatt
Title- / cover sheet

03.03.2011

GRO/PLE

&EAB

Inhaltsverzeichnis
Table of contents

03.03.2011

GRO/PLE

&EAB

Inhaltsverzeichnis
Table of contents

03.03.2011

GRO/PLE

&EAB

Inhaltsverzeichnis
Table of contents

03.03.2011

GRO/PLE

&EAB

Inhaltsverzeichnis
Table of contents

03.03.2011

GRO/PLE

&EBH

Revisionsbersicht
Revision overview

03.03.2011

GRO/PLE

&EDB

Strukturkennzeichenbersicht
Structure indicator

03.03.2011

GRO/PLE

&EDB

Informations-Blatt
Information-sheet

03.03.2011

GRO/PLE

&EDB

Informations-Blatt
Information-sheet

03.03.2011

GRO/PLE

&EFS

10

Einspeisung
Incoming

=0

03.03.2011

GRO/PLE

&EFS

11

Steuerspannung 24VDC
Control voltage 24VDC

=0

03.03.2011

GRO/PLE

&EFS

12

Not-Halt
Emergency stop

=0

03.03.2011

GRO/PLE

&EFS

13

Separator
Separator

=01

03.03.2011

GRO/PLE

&EFS

14

Separator
Separator

=01

03.03.2011

GRO/PLE

&EFS

15

Separator Drehzahlmessung
Separator speed measuring

=01

03.03.2011

GRO/PLE

&EFS

16

Separator Signale
Separator signals

=01

03.03.2011

GRO/PLE

&EFS

17

Separator Vibro
Separator vibro

=01

03.03.2011

GRO/PLE

&EFS

18

Separator Ventile
Separator valves

=01

03.03.2011

GRO/PLE

&EFS

19

Freigabe Produkt Temperaturregelung


Release product temperature control

=11

03.03.2011

GRO/PLE

Date
Editor
Tested
Changes

Seitenbeschreibung
Page description

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Inhaltsverzeichnis
Table of contents

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EAB

Bl./Sh.
2
67 Bl./Sh.

Inhaltsverzeichnis
Table of contents
Dokumentenart
Document type

Seite
Page

Date

Anlage
Plant

Einbauort
Mounting place

Datum
Date

Bearbeiter
Editor

&EFS

20

Produkt Temperaturregelung
Product temperature control

=11

03.03.2011

GRO/PLE

&EFS

21

Signalaustausch
Signal exchange

=100

03.03.2011

GRO/PLE

&EFS

22

SPS bersicht
PLC overview

=00

03.03.2011

GRO/PLE

&EFS

23

SPS Spannungsversorgung
PLC power supply

=00

03.03.2011

GRO/PLE

&EFS

24

SPS bersicht
PLC overview

=00

03.03.2011

GRO/PLE

&EFS

25

SPS bersicht
PLC overview

=00

03.03.2011

GRO/PLE

&EFS

26

SPS bersicht
PLC overview

=00

03.03.2011

GRO/PLE

&ELU

27

Aufbauplan
Arrangement drawing

03.03.2011

GRO/PLE

&ELU

28

Aufbauplan
Arrangement drawing

03.03.2011

GRO/PLE

&ELU

29

D10
D10

03.03.2011

GRO/PLE

&ELU

30

Not-Halt-Box
Energency stop box

03.03.2011

GRO/PLE

&ELU

31

Stromwandler
Current transformer

03.03.2011

GRO/PLE

&ELU

32

Motorvollschutzrelais
Motor protection relay

03.03.2011

GRO/PLE

&EMA

33

Klemmenplan =0+-GLAND
Terminal connection diagram =0+-GLAND

=0

03.03.2011

GRO/PLE

&EMA

34

Klemmenplan =0+-GLAND
Terminal connection diagram =0+-GLAND

=0

03.03.2011

GRO/PLE

&EMA

35

Klemmenplan =0+-24M
Terminal connection diagram =0+-24M

=0

03.03.2011

GRO/PLE

&EMA

36

Klemmenplan =0+-PE
Terminal connection diagram =0+-PE

=0

03.03.2011

GRO/PLE

&EMA

37

Klemmenplan =0+-SC
Terminal connection diagram =0+-SC

=0

03.03.2011

GRO/PLE

&EMA

38

Klemmenplan =0+-X1
Terminal connection diagram =0+-X1

=0

03.03.2011

GRO/PLE

Date
Editor
Tested
Changes

Seitenbeschreibung
Page description

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Inhaltsverzeichnis
Table of contents

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EAB

Bl./Sh.
3
67 Bl./Sh.

Inhaltsverzeichnis
Table of contents
Dokumentenart
Document type

Seite
Page

Date

Anlage
Plant

Einbauort
Mounting place

Datum
Date

Bearbeiter
Editor

&EMA

39

Klemmenplan =0+-X2
Terminal connection diagram =0+-X2

=0

03.03.2011

GRO/PLE

&EMA

40

Klemmenplan =01+-X1
Terminal connection diagram =01+-X1

=01

03.03.2011

GRO/PLE

&EMA

41

Klemmenplan =01+-X2
Terminal connection diagram =01+-X2

=01

03.03.2011

GRO/PLE

&EMA

42

Klemmenplan =01+JB-1X10
Terminal connection diagram =01+JB-1X10

=01

+JB

03.03.2011

GRO/PLE

&EMA

43

Klemmenplan =01+JB-1X10_GLAND
Terminal connection diagram =01+JB-1X10_GLAND

=01

+JB

03.03.2011

GRO/PLE

&EMA

44

Klemmenplan =01+SB-1X20
Terminal connection diagram =01+SB-1X20

=01

+SB

03.03.2011

GRO/PLE

&EMA

45

Klemmenplan =100+-X2
Terminal connection diagram =100+-X2

=100

03.03.2011

GRO/PLE

&EMA

46

Klemmenplan =11+-X2
Terminal connection diagram =11+-X2

=11

03.03.2011

GRO/PLE

&EMB

47

Kabelbersicht
Cable layout

03.03.2011

GRO/PLE

&EMB

48

Kabelbersicht
Cable layout

03.03.2011

GRO/PLE

&EMB

49

Klemmenkasten bersicht
Terminal box overview

03.03.2011

GRO/PLE

&EMB

50

Hinweise zur Installation


Instructions for installation

03.03.2011

GRO/PLE

&EMB

51

Potentialausgleich Separator
Potential equalization Separator

03.03.2011

GRO/PLE

&EMC

52

Klemmenanschlussplan =0+-GLAND
Terminal connecting plan =0+-GLAND

03.03.2011

GRO/PLE

&EMC

53

Klemmenanschlussplan =0+-24M
Terminal connecting plan =0+-24M

03.03.2011

GRO/PLE

&EMC

54

Klemmenanschlussplan =0+-PE
Terminal connecting plan =0+-PE

03.03.2011

GRO/PLE

&EMC

55

Klemmenanschlussplan =0+-SC
Terminal connecting plan =0+-SC

03.03.2011

GRO/PLE

&EMC

56

Klemmenanschlussplan =0+-X1
Terminal connecting plan =0+-X1

03.03.2011

GRO/PLE

&EMC

57

Klemmenanschlussplan =0+-X2
Terminal connecting plan =0+-X2

03.03.2011

GRO/PLE

Date
Editor
Tested
Changes

Seitenbeschreibung
Page description

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Inhaltsverzeichnis
Table of contents

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EAB

Bl./Sh.
4
67 Bl./Sh.

Inhaltsverzeichnis
Table of contents
Dokumentenart
Document type

Seite
Page

Date

Anlage
Plant

Einbauort
Mounting place

Datum
Date

Bearbeiter
Editor

&EMC

58

Klemmenanschlussplan =01+-X1
Terminal connecting plan =01+-X1

03.03.2011

GRO/PLE

&EMC

59

Klemmenanschlussplan =01+-X2
Terminal connecting plan =01+-X2

03.03.2011

GRO/PLE

&EMC

60

Klemmenanschlussplan =01+JB-1X10
Terminal connecting plan =01+JB-1X10

03.03.2011

GRO/PLE

&EMC

61

Klemmenanschlussplan =01+JB-1X10_GLAND
Terminal connecting plan =01+JB-1X10_GLAND

03.03.2011

GRO/PLE

&EMC

62

Klemmenanschlussplan =01+SB-1X20
Terminal connecting plan =01+SB-1X20

03.03.2011

GRO/PLE

&EMC

63

Klemmenanschlussplan =100+-X2
Terminal connecting plan =100+-X2

03.03.2011

GRO/PLE

&EMC

64

Klemmenanschlussplan =11+-X2
Terminal connecting plan =11+-X2

03.03.2011

GRO/PLE

&EPB

65

Stckliste
Parts list

03.03.2011

GRO/PLE

&EPB

66

Stckliste
Parts list

03.03.2011

GRO/PLE

&EPB

67

Stckliste
Parts list

03.03.2011

GRO/PLE

Date
Editor
Tested
Changes

Seitenbeschreibung
Page description

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Inhaltsverzeichnis
Table of contents

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EAB

Bl./Sh.
5
67 Bl./Sh.

Revisionsbersicht
Revision overview
Revisionsname
Revision name

Revisionskommentar
Revision comment

Rev.01

As built

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Revisionsnderungsgrund
Revision on the basis of change

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Revisionsbersicht
Revision overview

Seitenname
Page name

Ersteller
Author

Datum
Date

GRO/PLE

03.02.2011

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EBH

Bl./Sh.
6
67 Bl./Sh.

Strukturkennzeichenbersicht
Structure indicator
Vollstndige Bezeichnung
Complete name
&EAA

Dokumentenart

&EAB

Dokumentenart

&EBH

Dokumentenart

&EDB

Dokumentenart

&EFS

Dokumentenart

&ELU

Dokumentenart

&EMA

Dokumentenart

&EMB

Dokumentenart

&EMC

Dokumentenart

&EPB

Dokumentenart

=0

Anlage

=00

Anlage

=01

Anlage

=100

Anlage

=11

Anlage

=Additions

Anlage

=Customer

Anlage

=MCC

Anlage

+JB

Einbauort

+L

Einbauort

+SB

Einbauort

Date
Editor
Tested
Changes

Beschriftung
Labelling

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Strukturbeschreibung
Structure descprition

Vollstndige Bezeichnung
Complete name

Beschriftung
Labelling

Strukturbeschreibung
Structure descprition

Deckblatt
Cover sheet
Inhaltsverzeichnis
Table of contents
Revisionsbersicht
Revision overview
Strukturkennzeichen bersicht / Vorschriften
Structure indentification overview / instructions
Stromlaufplan
Circuit diagram
Aufbauplan
Arrangement drawing
Klemmenplan
Terminal connection diagram
Kabelbersicht
Cable layout
Klemmenanschlussplan
Terminal connecting plan
Stckliste
Parts list
Einspeisung
Incoming
SPS
PLC
Separator
Separator
Signalaustausch
Signal exchange
Zulaufpumpe
Feed pump
Zugabe
Addition
Kunde
Customer
Motorsteuerung
Motor starter
Abzweigdose
Junction box
Lokal
Local
Sensorblock
Sensor bloc

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Strukturkennzeichenbersicht
Structure indicator

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EDB

Bl./Sh.
7
67 Bl./Sh.

Vorschriften / Spezifikation
Instruction / specification
Schaltschrank :
Control cabinet :
Bezeichnung Schaltschrank
Name control cabinet

Ausfhrung:
Version:
CC

Aderkennzeichnung
Core indentification

YES

Lackierung Gehuse
Painting cabinet

Munsell 7.5 BG 7/2

Potentialbezeichnung
Potential designation

NO

Schutzart
Protective rating

IP54

Halogenfreie Verdrahtung / Kanle


Halogen free wiring / channels

YES

Umgebungstemperatur
Ambient temperature

~45 C

Kabelkennzeichnungsschilder
Cable marking plates

YES

Klassifizierung
Classification

...

Kennzeichnungsschilder
Marking plates

PLASTIC WHITE, LETTERS BLACK

Schnittstelle:
Interface:
Bus Verbindung zum Kunden PLC
Bus connection to customer PLC

NO

Einspeisung:
Incoming:
Netz-/ Anschlussspannung
Mains- / side voltage

230V AC

Netzfrequenz
Mains frequency

60 Hz

Drehfeld
Rotary field

CLOCKWISE ROTATION

Spannungstoleranz
Voltage tolerance

+/-5 %

Kabeleinfhrung
Cable inlet

BOTTOM

Einspeisung redundant
Incoming redundant

NO

Steuerspannungen:
Control voltages:

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Steuerspannung 1
Control voltage 1

230V AC

Steuerspannung 2
Control voltage 2

24V DC

Benennung/Description:

Informations-Blatt
Information-sheet

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EDB

Bl./Sh.
8
67 Bl./Sh.

Verdrahtung
Wiring
Stromkreise
Electrical circuits

Leiter
Conductor

Hauptstromkreise
Main circuits

230V AC

L1
L2
L3
N
PE

Farbe
Colour
Schwarz
Black
Schwarz
Black
Schwarz
Black
Hellblau
Light blue
Grn / Gelb
Green / yellow

Querschnitt
Cross-section

Stromkreise
Electrical circuits

Steuerspannung
Control voltage

1,5mm

Leiter
Conductor

Farbe
Colour
Rot
Red
Rot / Wei
Red / white

Querschnitt
Cross-section

Rot
Red
Blau
Blue

Wei
White
Braun
Brown

Messleitung
Measuring circuit

Wei
White

0,75mm

Stromwandlerleitungen
Current transformer lines

Schwarz
Black

2,5mm

Verriegelungsleitungen (AC/DC)
Interlocking conductors (AC/DC)

Orange

0,75mm

230V AC

L
N

"

1,5mm

2,5mm

24V DC

+
-

Analog abgeschirmt
Analog screened

L+
M

Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

0,75mm

"

"

Steuerspannung
Control voltage

Date
Editor
Tested

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Informations-Blatt
Information-sheet

"

0,75mm

"

Rev.01 =
As built +

Sprache:
Language:

0,75mm

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EDB

Bl./Sh.
9
67 Bl./Sh.

23

31

24

/21.1 32

13

230V AC

L1 / 11.0
N / 11.0

14

-S1

-F1
C 6A

Daten Einspeisung:
Data incoming:

-WD001
MPRXCX
2x2,5 mm

Date
Editor
Tested
Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

Filterlfter
Filter fan

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Umgebungstemperatur:
Ambient temperature:

~45 C

50 m

PE

PE

PE

-1M

-1T

-1G

U:

Benennung/Description:

Einspeisung
Incoming

230V AC
60 Hz

f:
P:

Erdung Gehuse 1
Earthing cabinet 1

PE

M
1~

Erdung Tr 1
Earthing door 1

Einspeisung
Incoming

max. Kabellnge:
Max. Cable length:

Erdung Montageplatte 1
Earthing mounting plate 1

Erdung Schirm
Earthing screen

=Customer
+L-X

Vorsicherung:
Pre-fuse:

L
N

L1

PE

19/18W
Schaltschranklfter
Cabinet fan

2,5 mm

-PE

-PE

-M1

Changes

-PE

-X1

-PE
4

-SC
3

-PE

GLAND

-X1

-PE

min. Querschnitt:
Min. Cross-section:

Icn:
Vollaststrom:
Full load current:

Rev.01 = 0
As built +

Sprache:
Language:

~2 A

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EFS

Bl./Sh.
10
67 Bl./Sh.

N/L2

230V AC

L1

10.9 / L1
10.9 / N

-T2

INPUT

GEA
power

-P1
x2

ON

OFF

x1

120/230VAC
24VDC/5A

A
B

M'

PE

L+'

L+

OUTPUT

M.A / 13.6
M.K / 22.0
M.R / 12.0
1

-24M

-PE

-PE

M.X / 18.0
24V DC
24V DC
24V DC

Steuerspannung DC
Control voltage DC

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Steuerspannung 24VDC
Control voltage 24VDC

L+.A / 13.6
L+.K / 23.0
L+.X / 12.0

Spannungsversorgung
Power supply

Rev.01 = 0
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EFS

Bl./Sh.
11
67 Bl./Sh.

24V DC

11.9 / L+.X

24V DC

L+.X / 16.0

=00-K1
/24.4

E2.7
8

X10

11.9 / M.R

M.R / 14.0

GLAND

-X2

-PE

Brcke entfernen bei


Anschlu eines
externen Not-Halt!
Remove link in case of
an external
emergency stop!

-WG008
MPRXCX
2x1,5 mm

=MCC
PE

/13.0
PE

Separator
Not-Halt
Separator
emergency stop
Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Not-Halt
Emergency stop

Rev.01 = 0
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EFS

Bl./Sh.
12
67 Bl./Sh.

Separatormotor
Separator motor

11.9 / L+.A
11.9 / M.A

24V DC

24V DC

L+.A / 14.0
M.A / 15.0

=MCC
/12.1
/14.1
/19.1

Strommessung Separator
Current measuring separator

...V/50/60Hz
L1

L2

L3

=00-K1
4-20mA = 0-50A
/25.5

-WG006
MPRXCX
2x1,5 mm

AI0-I

X13
2

11

-X2

-X2
1

A1

A2

14

2
GLAND
-PE

PE

12

-K1
/14.4

-Q1

-X1

8
output
0/4-20mA

A1

T1

input
0-1A

GLAND
-PE

PE

7+

-X1

9-

0-.../.../1A

S2

50/1A

*0_9_011

S1

-B1

-T1

-WG007
MPRXCX
2x2,5 mm

-B2

-F1
A2

T2

-PE

M
3~

*0_1_001
...kW/...A

T1

T2

Separator
Separator

Date
Editor
Tested
Changes

Date

Name

PE

W1

V1

Linkslauf
Anti-clockwise rotation
U1

GEA_Westfalia_Separator

03.03.2011
BEE/PLE
03.02.2011 KA

PTC-Fhler
Separator
PTC-feeler
separator

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Separator
Separator

Rev.01 = 01
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EFS

Bl./Sh.
13
67 Bl./Sh.

13.9 / L+.A

24V DC

24V DC

=00-K1

L+.A / 15.0

=00-K1

/24.5

/24.5

E0.0

E0.1
2

X11

X11

=00-K1
/25.4

A1.0

A1

X12

A2

-K1
12.9 / M.R

M.R / 19.0

-X2
WG009 / 16.2

GLAND

21

20

-PE

WG009. / 16.3

-WG009
MPRXCX
4x1,5 mm

=MCC

14
11 /13.5

/13.0
PE

12
PE

Separator
Betrieb
Separator
operation
Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Separator
Strung
Separator
failure

Kunde:
Customer:
Projekt:
Project:

Separator
Start/Stop
Separator
start/stop
GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Separator
Separator

Rev.01 = 01
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EFS

Bl./Sh.
14
67 Bl./Sh.

14.9 / L+.A
13.9 / M.A

24V DC

24V DC

L+.A / 22.0

=00-K1
0-8200 r.p.m.
/24.5

E0.3

4+

X11

24VDC

-X2

2-

1+

5+

6-

-T2

-WG004
MPRXCX
7x1,5 mm

+JB

-1X10

*0_9_020
SI

-WG101
.-O
2x0,34 mm

+ BN = brown
- BU = blue

Drehzahlberwachung
Speed monitoring device

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Separator Drehzahlmessung
Separator speed measuring

Rev.01 = 01
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EFS

Bl./Sh.
15
67 Bl./Sh.

=00-K1

=00-K1

4-20mA
/25.5

4-20mA
/25.5

AI1-I

AI2-I

X13

=00-K1

X13

/24.5

E0.5
6

X11

24V DC

12.9 / L+.X

24V DC

L+.X / 19.0

14.1 / WG009

-WG004
MPRXCX
7x1,5 mm

GLAND

10

-X2

-PE

14.2 / WG009.

L+_1X10 / 17.1
PE

GLAND

-1X10

+JB

PE

-WG121
MPRXCX
4x1,5 mm

+SB

*1_9_002

*0_9_014
P

PSL/H
4-20mA

Reinoel
Ablaufdruck
Clean-oil
discharge pressure
Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

A/Q

-WG203
.-O
3x0,75 mm
1

-WG202
.-O
2x0,34 mm
1

-WG201
.-O
2x0,34 mm

-1X20

PE_1X20 / 18.6
M_1X20 / 18.5

*0_9_013
P

SMS
4-20mA

WMS

Schlammraumberwachung
Sludge space monitoring

Kunde:
Customer:
Projekt:
Project:

Wasserabfuhr
Water monitoring system

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Separator Signale
Separator signals

Rev.01 = 01
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EFS

Bl./Sh.
16
67 Bl./Sh.

=00-K1
/24.5

E1.7

-X2

11

16

X11

-WG011
MPRXCX
7x1,5 mm

+JB

16.3 / L+_1X10

M_1X10 / 18.3
-1X10

11

Reserve
Spare

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

10

Reserve
Spare

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Separator Vibro
Separator vibro

Rev.01 = 01
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EFS

Bl./Sh.
17
67 Bl./Sh.

=00-K1

=00-K1

=00-K1

=00-K1

/25.4

/25.4

/25.4

/25.4

/25.4

A0.2

A0.1

A0.4

A0.5

X12
6

X12
5

X12

X12

X12

=00-K1

A0.0

11.9 / M.X

19

GLAND

17

GLAND

10

PE

18
18
11

17

16

14

15

-PE

GLAND

13

-X2

12

-PE

-WG011
MPRXCX
7x1,5 mm

17.1 / M_1X10

14

PE

-PE

-1X10

PE

16

-PE

-PE

GLAND

13

GLAND

-1X10

12

-PE

15

+JB

-WG122
MPRXCX
3x1,5 mm

+SB

16.3 / M_1X20

16.3

Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

Verdrngungs- und
Fllwasser
Displacem- and
filling water
GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

PE

Benennung/Description:

Separator Ventile
Separator valves

PE

*0_7_011
-

*0_7_010

PE

-WG205
.-J
3x0,75 mm

*9_7_005

Steuerwasser
Operating water

PE

-WG204
.-J
3x0,75 mm

Zulaufventil
Feed valve

PE

*9_7_004
-

*8_7_002

Date
Editor
Tested

-WG106
MPRXCX
2x1,5 mm
+

-WG105
MPRXCX
2x1,5 mm
+

-WG010
MPRXCX
2x1,5 mm

-1X20

PE_1X20

Kreislaufventil
Circulation valve

Wasserabfuhrventil
Water discharge valve

Rev.01 = 01
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EFS

Bl./Sh.
18
67 Bl./Sh.

24V DC

16.9 / L+.X

=00-K1
/24.5

E1.0
9

X11

14.9 / M.R

M.R / 21.0
GLAND

-X2

-PE
1

Brcke entfernen bei


Anschlu einer
Zulaufpumpe!
(Option)
Link remove at
connection of an feed
pump! (optional)

-WG005
MPRXCX
2x1,5 mm

=MCC
PE

/13.0
PE

Rckmeldung Zulaufpumpe
Feed back feed pump

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Freigabe Produkt Temperaturregelung


Release product temperature control

Rev.01 = 11
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EFS

Bl./Sh.
19
67 Bl./Sh.

min / max
Temperaturberwachung
Min / max
temperature monitoring

=00-K1
4-20mA = 0-120C
/25.5
/25.5

AIR-P

16

X13

15

X13

AIR-N

SC

-X2

=0-SC

-SC

-WG003
.CY-O
4x1,5 mm

*0_9_006

PT100
2

PT100

Reserve
Spare

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Produkt Temperaturregelung
Product temperature control

min / max
Temperaturberwachung
Min / max
temperature monitoring
Rev.01 = 11
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EFS

Bl./Sh.
20
67 Bl./Sh.

=00-K1

=00-K1

=00-K1

/25.4

/25.4

/25.4

/25.4

A1.3

A1.4

A1.5

14
A1

A1

A1

8
A1

A2

-K4
A2

-K3
A2

-K2
A2

-K1

X12

13

X12

12

X12

=00-K1

A0.7
X12

19.9 / M.R

Sammelstrung
Common failure

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GLAND

TAH Temperatur
Alarm max
TAH temperature
alarm max
GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

PE

-WG004
MPRXCX
2x1,5 mm
PE

-X

PE
7

GLAND

Wasserschlossalarm
Water seal broken alarm

14

12

11

11

-X

PE

-WG003
MPRXCX
2x1,5 mm
PE

-X

Kunde

3
-WG002
MPRXCX
2x1,5 mm

PE

=Customer
+L-X

/21.5

PE

GLAND

-X2

-K4

/21.3

-PE

-WG001
MPRXCX
2x1,5 mm

14

12

14

12

31
/10.1

-K3

/21.2

32

11

/21.1

12

12

-K2

=0-S1

11 /21.5

11 /21.3

12

14

12

12

-K1

14

14
11 /21.2

11

14
11 /21.0

GLAND

14

-X

TAL Temperatur
Alarm min
TAL temperature
alarm min
Benennung/Description:

Signalaustausch
Signal exchange

Rev.01 = 100
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EFS

Bl./Sh.
21
67 Bl./Sh.

=00-K1

=00-K1
/25.5

/25.5

/25.5

/25.5

AI1-C

AI2-C
-

AI3-C

X13

X13
12

X13

X13

=00-K1

AI0-C
-

8
Name

=00-K1

24V DC

M.K / 23.0

Date
Editor
Tested
Date

/24.5

Masse Analog
Ground analog

Changes

=00-K1

E0.7
X11

15.9 / L+.A
11.9 / M.K

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

Masse Analog
Ground analog

Masse Analog
Ground analog

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Masse Analog
Ground analog

Benennung/Description:

SPS bersicht
PLC overview

Rev.01 = 00
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EFS

Bl./Sh.
22
67 Bl./Sh.

-K1

-X12

...
...
...
...

+1.7
+2.7
+0.7
+1.7

8
7
6
5
4
3
2

10

11

12

13

14

15

16

AI1-C

AI2-U

AI2-I

AI2-C

AI3-U

AI3-I

AI3-C

M ana

M ana

AIR-P

AIR-N

16

15

14

13

12

11

10

+2.0
+2.1
+2.2
+2.3
+2.4
+2.5
+2.6
+2.7
2L+
2L+
2M
3L+
3L+
3M
1L+
1M

13
12
11
10
9
8
7
6
5
4
3
2
1

-X1
L+
M
AT1
AT2

4
3
2
1

1M /24.4
X10:16

1L+ /24.4
X10:15

3M /24.4
X10:14

3L+ /24.4
X10:12

X10:11

X10:9

2M /24.4

DO/DI 24VDC
Pover Supply
2L+ /24.4

6
M ana

AO1-I

4
AO1-U

M ana

2
AO0-I

AO0-U
L+

AT2

Digital Input 24VDC

X1:4

X1:3

X1:2

X1:1

AT1

Analog Output

-X10

14

-PE

Date
Editor
Tested
Name

PT100

11.9 / L+.K
22.9 / M.K

Date

10

-X14

A
B
SC

Changes

11

AI1-I

3
AI0-C

Analog Input

A
B
SC

12

AI1-U

2
AI0-I

X2/MPI

-X13

AI0-U

A
B
SC

13

15

PE

A
B
SC

DI +0.0
DI +0.0
DO +0.0
DO +1.0

14

16

X10:PE

1L+
=
1M
=
2L+,2M=
3L+,3M=

X5/P-BUS

15

Input 24VDC, 4A

MMC

-X7

+1.7
+1.6
+1.5
+1.4
+1.3
+1.2
+1.1
+1.0
+0.7
+0.6
+0.5
+0.4
+0.3
+0.2
+0.1
+0.0

16

Digital Output 24VDC 0,5A

+1.7
+1.6
+1.5
+1.4
+1.3
+1.2
+1.1
+1.0
+0.7
+0.6
+0.5
+0.4
+0.3
+0.2
+0.1
+0.0

-X11

Digital Input 24VDC

6ES7613-1SB02-0AC0

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

SPS Spannungsversorgung
PLC power supply

Rev.01 = 00
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EFS

Bl./Sh.
23
67 Bl./Sh.

-K1

X10:1
X10:2
X10:3
X10:4
X10:5
X10:6
X10:7
Separator Not-Halt
Separator emergency stop

24V

=0-T2:L+

/12.1

/23.5

X10:8

X10:9
X10:10

0V

/23.5

24V

/23.5

X10:11
X10:12
X10:13

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

0V

/23.5

24V

/23.5

0V

/23.5

X10:14
X10:15
X10:16

E2.0

E0.0

E2.1

E0.1

E2.2

E0.2

E2.3

E0.3

E2.4

E0.4

E2.5

E0.5

E2.6

E0.6

E2.7

E0.7

2L+

E1.0

2L+

E1.1

2M

E1.2

3L+

E1.3

3L+

E1.4

3M

E1.5

1L+

E1.6

1M

E1.7

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

SPS bersicht
PLC overview

X11:1
X11:2

/14.1

=01-X2:20

Separator Strung
Separator failure

/14.2

=01-X2:21

Separator Strung
Separator failure

/15.2

=01-T2:4+

Drehzahlberwachung
Speed monitoring device

/16.3

=01-X2:10

Wasserabfuhr
Water monitoring system

/22.1

=01-T2:5+

/19.1

=MCC

Separator Strung
Separator failure

/17.4

=01-X2:11

Reserve
Spare

X11:3
X11:4
X11:5
X11:6
X11:7
X11:8

X11:9
X11:10
X11:11
X11:12
X11:13
X11:14
X11:15
X11:16

Rev.01 = 00
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EFS

Bl./Sh.
24
67 Bl./Sh.

-K1

Zulaufventil
Feed valve

=01-X2:12

/18.1

Verdrngungs- und Fllwasser


Displacem- and filling water

=01-X2:15

/18.4

Steuerwasser
Operating water

=01-X2:14

/18.3

X12:1
X12:2
X12:3
X12:4

Kreislaufventil
Circulation valve

=01-X2:17

/18.5

Wasserabfuhrventil
Water discharge valve

=01-X2:18

/18.6

X12:5
X12:6
X12:7

Sammelstrung
Common failure

=100-K1:A1

/21.1

X12:8

A0.0

AI0-U

A0.1

AI0-I

A0.2

AI0-C

A0.3
A0.4

AI1-U

AI1-I

A0.5

AI1-C

A0.6
V

AI2-U

AI2-I

A0.7

AI2-C
-

Separator Start/Stop
Separator start/stop

=01-K1:A1

/14.4

X12:9
X12:10
X12:11

Wasserschlossalarm
Water seal broken alarm

=100-K2:A1

/21.2

TAH Temperatur Alarm max


TAH temperature alarm max

=100-K3:A1

/21.3

TAL Temperatur Alarm min


TAL temperature alarm min

=100-K4:A1

/21.5

X12:12
X12:13
X12:14
X12:15
X12:16

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

AI3-U

AI3-I

A1.0
A1.1

AI3-C

X13:1
X13:2
X13:3

/13.7

=01-T1:8

Strommessung Separator
Current measuring separator
Masse Analog
Ground analog

/22.2

X13:4
X13:5
X13:6

/16.1

=01-X2:6

/22.3

-K1:3

/16.2

=01-X2:8

Reinoel Ablaufdruck
Clean-oil discharge pressure
Masse Analog
Ground analog

X13:7
X13:8
X13:9

Schlammraumberwachung
Sludge space monitoring

/22.4

Masse Analog
Ground analog

/22.5

Masse Analog
Ground analog

X13:10
X13:11
X13:12

A1.2
A1.3

MANA

A1.4

Mana

X13:13
X13:14

A1.5
A1.6

AIR-P
PT100

A1.7

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

AIR-N

Benennung/Description:

SPS bersicht
PLC overview

X13:15
X13:16

/20.6

=11-X2:5

min / max Temperaturberwachung


Min / max temperature monitoring

/20.6

=11-X2:6

min / max Temperaturberwachung


Min / max temperature monitoring

Rev.01 = 00
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EFS

Bl./Sh.
25
67 Bl./Sh.

-K1

AO0-U
AO0-I
MANA

X14:1
X14:2
X14:3
X14:4

AO1-I
MANA

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

SPS bersicht
PLC overview

X14:5
X14:6

Rev.01 = 00
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EFS

Bl./Sh.
26
67 Bl./Sh.

410 mm
380 mm

54 mm

Terminals

=00-K1

PE
Cable
route

Terminals
PE
=0-S1

=0-P1

=0-M1

pocket for circuit diagram

10 mm

NO. _ HFO PURIFIER


CONTROL PANEL

600 mm
582 mm

360 mm
350 mm

Cabinet

Custody
space
for key

330

150

M10

=00-K1
=0-M1
=0-P1
=0-S1

27

Steuergert Timing unit


Filter / Lfter Filter / fan
Spannungsversorgung Power supply
Hauptschalter Isolator

36
54

15

10,2

Mastab 1:4,5 mm
Scale 1:4,5 mm

HFO 1/2

Gewicht: ca. 30kg


Weight: ca. 30kg
Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Aufbauplan
Arrangement drawing

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& ELU

Bl./Sh.
27
67 Bl./Sh.

Mountingplate

37x75

=01-T2

=01-T1

=01-K1
=100-K1
=100-K2
=100-K3
=100-K4

=0-F1

=0-T2

=0-24M

37x75

=11-X2

=100-X2

37x75

PE
37x75

=01-X2

=01-X1

=0-X2

=0-X1

37x75

37x75

PE

Date
Editor
Tested
Changes

Date

Name

Cable glands

Yard cable size

8x M20
6x M20
3x M20

10,0 - 12,5mm
12,0 - 14,5mm
Spare

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

0005-4515-600
0005-4516-600
0005-4443-630

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Aufbauplan
Arrangement drawing

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& ELU

Bl./Sh.
28
67 Bl./Sh.

Regelung Gert D10


Control unit D10
Taste
Button
GEA Westfalia Separator

Prozess Stop
Process stop
Prozess Start
Process start
Lampentest
Lamp test
Serienbetrieb
Series operation
Hilfe
Help
Separator
Separator
Zulauf
Feed
Schlamm
Sludge

1
2
3

4
S

F2

F3

F4

165

F1

6
7

SF
DC5V

ESC

FRCE
RUN

STOP

EDIT

202x155mm

Tiefe:
depth:

88mm

Gewicht:
weight:

1,35kg

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

PID

Zurck
Return

Process
STOP
Process
START

LAMPTEST
SERIES
1

Benennung/Description:

D10
D10

FEED

SLUDGE

PID

HOME
DIR

Bestell-nr.
order no.

0005-4050-430

Programm-Nr.
program-no.

8106-0D10-101

Rev.01 =
As built +

Sprache:
Language:

HELP

ENTER

215

Ausschnittmass:
cutout dimension:

Symbol
Symbol

Benennung
Designation

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& ELU

Bl./Sh.
29
67 Bl./Sh.

Not-Halt Gehuse mit Schutzkragen


Emergency stop cabinet with protective collar
=Additions
-S01

71 mm

54 mm

85 mm

Not-Halt-Box

m
5

109 mm

85 mm

61 mm

protection class: "IP 65"

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

Note: Installation should be carry out by customer!

18 mm

M20
8-13mm

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Not-Halt-Box
Energency stop box

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& ELU

Bl./Sh.
30
67 Bl./Sh.

Stromwandler
Current transformer
(TAID)
42

=Additions
-B1

84

50/1A
Stromwandler
Current transformer

60

57

56

4mm

5,5
50

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Stromwandler
Current transformer

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& ELU

Bl./Sh.
31
67 Bl./Sh.

Motorvollschutzrelais
Motor protection relay
(3RN10 10)

=Additions
-F1

91

Motorvollschutzrelais
Motor protection relay

22,5
5
A1

T1

86

A1 / A2 =

T2

T1 / T2 =
95 / 96 =

80

74
95

96

97

98

A2
10

10

90

62

97 / 98 =

Spannungsversorgung
power supply
PTC
PTC
Schliesser
NO-contact
Oeffner
NC-contact

28
57

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Motorvollschutzrelais
Motor protection relay

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& ELU

Bl./Sh.
32
67 Bl./Sh.

SC
SC
SC
SC
SC
SC
SC
SC

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

Kabeltyp
Cable type

Kabeltyp
Cable type

GLAND

-PE

&EFS/10.1

-WG008

SC

GLAND

-PE

&EFS/12.2

=01-WG006

SC

GLAND

-PE

&EFS/13.4

=01-WG007

SC

GLAND

-PE

&EFS/13.4

=01-WG009

SC

GLAND

-PE

&EFS/14.3

GLAND

GLAND

-PE

&EFS/16.3

SC

GLAND

-PE

&EFS/18.2

GLAND

GLAND

-PE

&EFS/18.7

=11-WG005

SC

GLAND

-PE

&EFS/19.2

=100-WG001

SC

GLAND

-PE

&EFS/21.1

=01+JB-1X10_GLAND
=01-WG010
=01+JB-1X10_GLAND

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =0+-GLAND
Terminal connection diagram =0+-GLAND

Zielbezeichnung
Target designation

Kabelname
Cable name

SC

Brcke
Link

-WD001

Zielbezeichnung
Target designation

Anschluss
Connection

=0+-GLAND

Klemme
Terminal

SC

Klemmenleistenbezeichnung
Terminal strip designation

Kabelname
Cable name

MPRXCX 2x2,5 mm

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

MPRXCX 2x2,5 mm

MPRXCX 4x1,5 mm

MPRXCX 7x1,5 mm

MPRXCX 2x1,5 mm

SC

Date
Editor
Tested
Name

Anschluss
Connection

Einspeisung
Incoming
Separator Not-Halt
Separator emergency stop
Separator Aus
Separator off
Entleerungsberwachung
Ejection monitoring
Separator Strung
Separator failure
Wasserabfuhr
Water monitoring system
Zulaufventil
Feed valve
Wasserabfuhrventil
Water discharge valve
Rckmeldung Zulaufpumpe
Feed back feed pump
Sammelstrung
Common failure

Date

=100
WG001
=11
WG005
=01
WG011
=01
WG010
=01
WG004
=01
WG009
=01
WG007
=01
WG006
=0
WG008
=0
WD001

Funktionstext
Function text

Changes

MPRXCX 7x1,5 mm

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

Rev.01 = 0
As built +

Sprache:
Language:

Seite / Spalte
Page / column

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMA

Bl./Sh.
33
67 Bl./Sh.

SC
SC

Date
Editor
Tested
Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

Kabeltyp
Cable type

Kabeltyp
Cable type

GLAND

-PE

&EFS/21.2

=100-WG003

SC

GLAND

-PE

&EFS/21.4

=100-WG004

SC

GLAND

-PE

&EFS/21.5

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =0+-GLAND
Terminal connection diagram =0+-GLAND

Zielbezeichnung
Target designation

Kabelname
Cable name

SC

Brcke
Link

=100-WG002

Zielbezeichnung
Target designation

Anschluss
Connection

=0+-GLAND

Klemme
Terminal

SC

Anschluss
Connection

Wasserschlossalarm
Water seal broken alarm
TAH Temperatur Alarm max
TAH temperature alarm max
TAL Temperatur Alarm min
TAL temperature alarm min

Klemmenleistenbezeichnung
Terminal strip designation

Kabelname
Cable name

=100
WG004
=100
WG003
=100
WG002

Funktionstext
Function text

Changes

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

Rev.01 = 0
As built +

Sprache:
Language:

Seite / Spalte
Page / column

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMA

Bl./Sh.
34
67 Bl./Sh.

Kabeltyp
Cable type

Kabeltyp
Cable type

Klemmenleistenbezeichnung
Terminal strip designation

-T2

&EFS/11.6

-PE

PE

=01-K1

A2

&EFS/11.6

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =0+-24M
Terminal connection diagram =0+-24M

Zielbezeichnung
Target designation

Kabelname
Cable name

13

Zielbezeichnung
Target designation

Anschluss
Connection

=01-X2

Funktionstext
Function text

Brcke
Link

Klemme
Terminal

Steuerspannung DC
Control voltage DC

Kabelname
Cable name

Anschluss
Connection

=0+-24M

Rev.01 = 0
As built +

Sprache:
Language:

Seite / Spalte
Page / column

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMA

Bl./Sh.
35
67 Bl./Sh.

Kabeltyp
Cable type

Kabeltyp
Cable type

Klemmenleistenbezeichnung
Terminal strip designation

-PE

&EFS/10.3

-M1

PE

PE

-PE

&EFS/10.5

-1M

PE

PE

-PE

&EFS/10.6

-1T

PE

PE

-PE

&EFS/10.6

-1G

PE

PE

-PE

&EFS/10.6

-PE

PE

-T2

PE

&EFS/11.6

-PE

PE

-24M

&EFS/11.6

Steuergert
Timing unit

-PE

PE

=00-K1

X10:PE

&EFS/23.6

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =0+-PE
Terminal connection diagram =0+-PE

Zielbezeichnung
Target designation

Kabelname
Cable name

PE

Erdung Schirm
Earthing screen
Filterlfter
Filter fan
Erdung Montageplatte 1
Earthing mounting plate 1
Erdung Tr 1
Earthing door 1
Erdung Gehuse 1
Earthing cabinet 1
Steuerspannung DC
Control voltage DC

Zielbezeichnung
Target designation

Anschluss
Connection

SC

Funktionstext
Function text

Brcke
Link

Klemme
Terminal

-SC

Kabelname
Cable name

Anschluss
Connection

=0+-PE

Rev.01 = 0
As built +

Sprache:
Language:

Seite / Spalte
Page / column

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMA

Bl./Sh.
36
67 Bl./Sh.

Changes

Date

Name

SC

-SC

&EFS/10.3

=11-X2

SC

SC

-SC

&EFS/20.7

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =0+-SC
Terminal connection diagram =0+-SC

Kabelname
Cable name

PE

Zielbezeichnung
Target designation

Anschluss
Connection

Klemme
Terminal

-PE

Zielbezeichnung
Target designation

Brcke
Link

Anschluss
Connection

Erdung Schirm
Earthing screen
min / max Temperaturberwachung
Min / max temperature monitoring

Date
Editor
Tested

=0+-SC

Kabelname
Cable name

Funktionstext
Function text

Kabeltyp
Cable type

Kabeltyp
Cable type

Klemmenleistenbezeichnung
Terminal strip designation

Rev.01 = 0
As built +

Sprache:
Language:

Seite / Spalte
Page / column

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMA

Bl./Sh.
37
67 Bl./Sh.

Kabeltyp
Cable type

=Customer+L-X

L1

-F1

&EFS/10.1

=Customer+L-X

-F1

&EFS/10.1

-S1

13

&EFS/10.4

Reserve
Spare
Filterlfter
Filter fan
=

-M1

-M1

Seite / Spalte
Page / column

&EFS/10.4
-S1

23

&EFS/10.5

Date
Editor
Tested
Changes

Zielbezeichnung
Target designation

Kabelname
Cable name

Zielbezeichnung
Target designation

Anschluss
Connection

Einspeisung
Incoming

Funktionstext
Function text

Brcke
Link

Klemme
Terminal

=0+-X1

Anschluss
Connection

Kabeltyp
Cable type

Klemmenleistenbezeichnung
Terminal strip designation

Kabelname
Cable name

MPRXCX 2x2,5 mm

=0
WD001

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =0+-X1
Terminal connection diagram =0+-X1

&EFS/10.5

Rev.01 = 0
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMA

Bl./Sh.
38
67 Bl./Sh.

Separator Not-Halt
Separator emergency stop

Separator Not-Halt
Separator emergency stop

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

=MCC-X

=MCC-X

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =0+-X2
Terminal connection diagram =0+-X2

Zielbezeichnung
Target designation
-T2

Anschluss
Connection

Brcke
Link

Klemme
Terminal

Zielbezeichnung
Target designation

Anschluss
Connection

=0+-X2

Kabelname
Cable name

Kabeltyp
Cable type

Klemmenleistenbezeichnung
Terminal strip designation
Kabeltyp
Cable type

Funktionstext
Function text

Kabelname
Cable name

MPRXCX 2x1,5 mm

=0
WG008

Seite / Spalte
Page / column

L+

=01-X2

=00-K1

X10:8

&EFS/12.1

&EFS/12.1

Rev.01 = 0
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMA

Bl./Sh.
39
67 Bl./Sh.

Zielbezeichnung
Target designation

Anschluss
Connection

Brcke
Link

Klemme
Terminal

Zielbezeichnung
Target designation

Anschluss
Connection

=01+-X1

Kabelname
Cable name

Kabeltyp
Cable type

Klemmenleistenbezeichnung
Terminal strip designation
Kabeltyp
Cable type

Funktionstext
Function text

Kabelname
Cable name

MPRXCX 2x2,5 mm

=01
WG007

Seite / Spalte
Page / column

Entleerungsberwachung
Ejection monitoring

=MCC-X_

-T1

&EFS/13.4

=MCC-X_

-T1

&EFS/13.4

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =01+-X1
Terminal connection diagram =01+-X1

Rev.01 = 01
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMA

Bl./Sh.
40
67 Bl./Sh.

Kabeltyp
Cable type

Zielbezeichnung
Target designation

Anschluss
Connection

Brcke
Link

Klemme
Terminal

Zielbezeichnung
Target designation

Kabelname
Cable name

Kabeltyp
Cable type

=01+-X2

Anschluss
Connection

Funktionstext
Function text

Klemmenleistenbezeichnung
Terminal strip designation

Kabelname
Cable name

=01
WG010
=01
WG011
=01
WG009
=01
WG004
=01
WG006

MPRXCX 2x1,5 mm

MPRXCX 7x1,5 mm

MPRXCX 4x1,5 mm

MPRXCX 7x1,5 mm

MPRXCX 2x1,5 mm

Seite / Spalte
Page / column

Separator Aus
Separator off

=MCC-X_

-K1

11

&EFS/13.4

=MCC-X_

-K1

12

&EFS/13.4

Drehzahlberwachung
Speed monitoring device

+JB-1X10

-T2

1+

&EFS/15.2

+JB-1X10

-T2

2-

&EFS/15.2

Reinoel Ablaufdruck
Clean-oil discharge pressure

+JB-1X10

=0-X2

&EFS/16.1

+JB-1X10

=00-K1

X13:5

&EFS/16.1

Separator Betrieb
Separator operation
Schlammraumberwachung
Sludge space monitoring
Separator Strung
Separator failure
Wasserabfuhr
Water monitoring system
Reserve
Spare
Zulaufventil
Feed valve

1
5
2

=00-K1

X13:8

&EFS/16.2

=11-X2

&EFS/16.3

10

=00-K1

X11:6

&EFS/16.3

+JB-1X10

10

11

=00-K1

X11:16

&EFS/17.4

-*8_7_002

12

=00-K1

X12:1

&EFS/18.1

-*8_7_002

13

=0-24M

&EFS/18.1

+JB-1X10

12

14

=00-K1

X12:3

&EFS/18.3

+JB-1X10

15

15

=00-K1

X12:2

&EFS/18.4

16

Kreislaufventil
Circulation valve
Wasserabfuhrventil
Water discharge valve
=
Betrieb
operation
Strung
failure

Date
Editor
Tested
Changes

Separator
Separator
Separator
Separator

&EFS/16.2

+JB-1X10

Steuerwasser
Operating water
Verdrngungs- und Fllwasser
Displacem- and filling water

+JB-1X10
=MCC

=MCC

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

&EFS/18.4

+JB-1X10

16

17

=00-K1

X12:5

&EFS/18.5

+JB-1X10

18

18

=00-K1

X12:6

&EFS/18.6

+JB-1X10

17

19

&EFS/18.7

=MCC

20

=00-K1

X11:1

&EFS/14.1

=MCC

21

=00-K1

X11:2

&EFS/14.2

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =01+-X2
Terminal connection diagram =01+-X2

Rev.01 = 01
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMA

Bl./Sh.
41
67 Bl./Sh.

Steuerwasser
Operating water
Wasserabfuhr
Water monitoring system
Drehzahlberwachung
Speed monitoring device

PE

Kabeltyp
Cable type

Zielbezeichnung
Target designation

Anschluss
Connection

Brcke
Link

Klemme
Terminal

Zielbezeichnung
Target designation

Kabelname
Cable name

Kabeltyp
Cable type

=01+JB-1X10

MPRXCX 7x1,5 mm

MPRXCX 7x1,5 mm

=01
WG004
=01
WG011

Anschluss
Connection

Funktionstext
Function text

Klemmenleistenbezeichnung
Terminal strip designation

Kabelname
Cable name

=01
WG122
=01
WG106
=01
WG105
=01
WG121
=01
WG101

.-O 2x0,34 mm

MPRXCX 4x1,5 mm

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

MPRXCX 3x1,5 mm

Seite / Spalte
Page / column

-PE

&EFS/18.3

PE

&EFS/16.4

BN

-*0_9_020

-X2

&EFS/15.2

BU

-*0_9_020

-X2

&EFS/15.2

Reinoel Ablaufdruck
Clean-oil discharge pressure

+SB-1X20

-X2

&EFS/16.1

+SB-1X20

-X2

&EFS/16.1

=
Schlammraumberwachung
Sludge space monitoring
Wasserabfuhr
Water monitoring system
Reserve
Spare

&EFS/16.1

+SB-1X20

-X2

&EFS/16.2

+SB-1X20

-X2

10

&EFS/16.3

&EFS/17.1

&EFS/17.3

10

11

-X2

11

&EFS/17.4
&EFS/17.1

Steuerwasser
Operating water

-*9_7_004

12

-*9_7_004

13

&EFS/18.3
&EFS/18.4

-X2

14

&EFS/18.3

Verdrngungs- und Fllwasser


Displacem- and filling water

-*9_7_005

14

-*9_7_005

15

-X2

15

&EFS/18.4

+SB-1X20

16

-X2

17

&EFS/18.5

+SB-1X20

10

17

-X2

19

&EFS/18.7

+SB-1X20

11

18

-X2

18

&EFS/18.6

PE

-PE

Kreislaufventil
Circulation valve
Wasserabfuhrventil
Water discharge valve
=
Verdrngungs- und Fllwasser
Displacem- and filling water

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =01+JB-1X10
Terminal connection diagram =01+JB-1X10

&EFS/18.4

Rev.01 = 01
As built + JB

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMA

Bl./Sh.
42
67 Bl./Sh.

SC
SC
SC

Date
Editor
Tested
Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

Kabeltyp
Cable type

Kabeltyp
Cable type

=0-GLAND

GLAND

+SB-1X20

PE:PE

GLAND

=0-GLAND

GLAND

-WG105

SC

GLAND

-PE

&EFS/18.3

-WG106

SC

GLAND

-PE

&EFS/18.4

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =01+JB-1X10_GLAND
Terminal connection diagram =01+JB-1X10_GLAND

=01
WG004
=01
WG011

GLAND

Zielbezeichnung
Target designation

Kabelname
Cable name

PE:PE

Brcke
Link

+SB-1X20

Zielbezeichnung
Target designation

Anschluss
Connection

=01+JB-1X10_GLAND

MPRXCX 7x1,5 mm

MPRXCX 7x1,5 mm

Klemme
Terminal

SC

Anschluss
Connection

Wasserabfuhr
Water monitoring system
Wasserabfuhrventil
Water discharge valve
Steuerwasser
Operating water
Verdrngungs- und Fllwasser
Displacem- and filling water

Klemmenleistenbezeichnung
Terminal strip designation

Kabelname
Cable name

=01
WG106
=01
WG105
=01
WG122
=01
WG121

Funktionstext
Function text

Changes

MPRXCX 4x1,5 mm

MPRXCX 3x1,5 mm

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

SC

&EFS/16.3
SC

&EFS/18.7

Rev.01 = 01
As built + JB

Sprache:
Language:

Seite / Spalte
Page / column

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMA

Bl./Sh.
43
67 Bl./Sh.

Kabeltyp
Cable type

Klemmenleistenbezeichnung
Terminal strip designation

+JB-1X10

&EFS/16.1

BK

-*1_9_002

+JB-1X10

&EFS/16.1

=01
WG121
=01
WG122

Kabelname
Cable name

Zielbezeichnung
Target designation

Anschluss
Connection

-*1_9_002

Zielbezeichnung
Target designation

Brcke
Link

Klemme
Terminal

WH

Funktionstext
Function text

Kabelname
Cable name

Reinoel Ablaufdruck
Clean-oil discharge pressure

=01
WG205
=01
WG204
=01
WG203
=01
WG202
=01
WG201

Anschluss
Connection

=01+SB-1X20

MPRXCX 3x1,5 mm

MPRXCX 4x1,5 mm

Kabeltyp
Cable type

.-O 2x0,34 mm

.-O 2x0,34 mm

.-O 3x0,75 mm

.-J 3x0,75 mm

.-J 3x0,75 mm

Seite / Spalte
Page / column

Schlammraumberwachung
Sludge space monitoring

WH

-*0_9_014

BK

-*0_9_014

+JB-1X10

&EFS/16.2

+JB-1X10

&EFS/16.3

&EFS/16.2

Wasserabfuhr
Water monitoring system

BK

-*0_9_013

A/Q

BN

-*0_9_013

&EFS/16.3

GY

-*0_9_013

&EFS/16.3

Kreislaufventil
Circulation valve

BN

-*0_7_010

BU

-*0_7_010

+JB-1X10

16

&EFS/18.5
&EFS/18.5

Wasserabfuhrventil
Water discharge valve

BN

-*0_7_011

10

+JB-1X10

17

&EFS/18.7

BU

-*0_7_011

11

+JB-1X10

18

&EFS/18.6

-*0_7_010

PE

PE

+JB-1X10_GLAND

GLAND

-*0_7_011

PE

PE

+JB-1X10_GLAND

GLAND

Kreislaufventil
Circulation valve
Wasserabfuhrventil
Water discharge valve

PE
PE

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =01+SB-1X20
Terminal connection diagram =01+SB-1X20

SC
SC

&EFS/18.7

Rev.01 = 01
As built + SB

Sprache:
Language:

&EFS/18.6

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMA

Bl./Sh.
44
67 Bl./Sh.

Kabeltyp
Cable type

Zielbezeichnung
Target designation

Anschluss
Connection

Brcke
Link

Klemme
Terminal

Zielbezeichnung
Target designation

Kabelname
Cable name

Kabeltyp
Cable type

=100+-X2

Anschluss
Connection

Funktionstext
Function text

Klemmenleistenbezeichnung
Terminal strip designation

Kabelname
Cable name

=100
WG004
=100
WG003
=100
WG002
=100
WG001

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

Seite / Spalte
Page / column

Sammelstrung
Common failure

=Customer+L-X

-K1

11

&EFS/21.1

=Customer+L-X

-K1

14

&EFS/21.1

Wasserschlossalarm
Water seal broken alarm

=Customer+L-X

-K2

11

&EFS/21.2

=Customer+L-X

-K2

14

&EFS/21.2

TAH Temperatur Alarm max


TAH temperature alarm max

=Customer+L-X

-K3

11

&EFS/21.3

=Customer+L-X

-K3

14

&EFS/21.4

TAL Temperatur Alarm min


TAL temperature alarm min

=Customer+L-X

-K4

11

&EFS/21.5

=Customer+L-X

-K4

14

&EFS/21.5

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =100+-X2
Terminal connection diagram =100+-X2

Rev.01 = 100
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMA

Bl./Sh.
45
67 Bl./Sh.

Kabeltyp
Cable type

Zielbezeichnung
Target designation

Anschluss
Connection

Brcke
Link

Klemme
Terminal

Zielbezeichnung
Target designation

Kabelname
Cable name

Kabeltyp
Cable type

=11+-X2

Anschluss
Connection

=11
WG003
=11
WG005

Funktionstext
Function text

Klemmenleistenbezeichnung
Terminal strip designation

Kabelname
Cable name

MPRXCX 2x1,5 mm

.CY-O 4x1,5 mm

Seite / Spalte
Page / column

Rckmeldung Zulaufpumpe
Feed back feed pump

=MCC

=01-X2

&EFS/19.1

=MCC

=00-K1

X11:9

&EFS/19.1

Reserve
Spare

-*0_9_006

&EFS/20.5

-*0_9_006

&EFS/20.5

-*0_9_006

=00-K1

X13:15

&EFS/20.6

-*0_9_006

=00-K1

X13:16

&EFS/20.6

SC

SC

=0-SC

SC

&EFS/20.7

min / max Temperaturberwachung


Min / max temperature monitoring
min / max Temperaturberwachung
Min / max temperature monitoring
=

SC

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

-WG003

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =11+-X2
Terminal connection diagram =11+-X2

Rev.01 = 11
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMA

Bl./Sh.
46
67 Bl./Sh.

Kabelbersicht
Cable layout
Kabelname
Cable name

/Seite.Pfad
/page.path

Ziel (bis)
Target (up to)

Kabeltyp
Cable type

Adern gesamt
Wires total

Adern
verwendet
Wires used

Querschnitt
Cross-section

Lnge
Length

Verschraubung / Klemmbereich
Cable gland / clamping range

=0-WD001

&EFS/10.1

=0-GLAND;=0-X1

=Customer+L-X

MPRXCX

2x

2,5 mm

M20x1,5 / 12-14,5mm

=0-WG008

&EFS/12.1

=0-GLAND;=0-X2

=MCC-X

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

=01-WG004

&EFS/15.1

=0-GLAND;=01-X2

=01+JB-1X10_GLAND;
=01+JB-1X10

MPRXCX

7x

1,5 mm

M20x1,5 / 12-14,5mm

=01-WG006

&EFS/13.4

=0-GLAND;=01-X2

=MCC-X_

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

=01-WG007

&EFS/13.4

=0-GLAND;=01-X1

=MCC-X_

MPRXCX

2x

2,5 mm

M20x1,5 / 12-14,5mm

=01-WG009

&EFS/14.1

=0-GLAND;=01-X2

=MCC

MPRXCX

4x

1,5 mm

M20x1,5 / 12-14,5mm

=01-WG010

&EFS/18.1

=0-GLAND;=01-X2

=01-*8_7_002

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

=01-WG011

&EFS/18.3

=0-GLAND;=01-X2

=01+JB-1X10_GLAND;
=01+JB-1X10

MPRXCX

7x

1,5 mm

M20x1,5 / 12-14,5mm

=01-WG101

&EFS/15.1

=01+JB-1X10

=01-*0_9_020

.-O

2x

0,34 mm

M12x1,5 / 3-6mm

=01-WG105

&EFS/18.3

=01+JB-1X10;
=01+JB-1X10_GLAND

=01-*9_7_004

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

=01-WG106

&EFS/18.4

=01+JB-1X10;
=01+JB-1X10_GLAND

=01-*9_7_005

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

=01-WG121

&EFS/16.1

=01+JB-1X10;
=01+JB-1X10_GLAND

=01+SB-1X20

MPRXCX

4x

1,5 mm

M20 Z14 / 12-14,5mm

=01-WG122

&EFS/18.5

=01+JB-1X10;
=01+JB-1X10_GLAND

=01+SB-1X20

MPRXCX

3x

1,5 mm

M20 Z14 / 12-14,5mm

=01-WG201

&EFS/16.1

=01+SB-1X20

=01-*1_9_002

.-O

2x

0,34 mm

Integrated in the sensor


block

=01-WG202

&EFS/16.2

=01+SB-1X20

=01-*0_9_014

.-O

2x

0,34 mm

Integrated in the sensor


block

=01-WG203

&EFS/16.3

=01+SB-1X20

=01-*0_9_013

.-O

3x

0,75 mm

Integrated in the sensor


block

=01-WG204

&EFS/18.5

=01+SB-1X20

=01-*0_7_010

.-J

3x

0,75 mm

Integrated in the sensor


block

=01-WG205

&EFS/18.6

=01+SB-1X20

=01-*0_7_011

.-J

3x

0,75 mm

Integrated in the sensor


block

=100-WG001

&EFS/21.1

=0-GLAND;=100-X2

=Customer+L-X

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

Date
Editor
Tested
Changes

Quelle (von)
Source (from)

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Kabelbersicht
Cable layout

Rev.01 =
As built +

Sprache:
Language:

Bemerkung
Remark

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMB

Bl./Sh.
47
67 Bl./Sh.

Kabelbersicht
Cable layout
Kabelname
Cable name

/Seite.Pfad
/page.path

Ziel (bis)
Target (up to)

Kabeltyp
Cable type

Adern gesamt
Wires total

Adern
verwendet
Wires used

Querschnitt
Cross-section

Lnge
Length

Verschraubung / Klemmbereich
Cable gland / clamping range

=100-WG002

&EFS/21.2

=0-GLAND;=100-X2

=Customer+L-X

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

=100-WG003

&EFS/21.3

=0-GLAND;=100-X2

=Customer+L-X

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

=100-WG004

&EFS/21.5

=0-GLAND;=100-X2

=Customer+L-X

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

=11-WG003

&EFS/20.5

=11-X2

=11-*0_9_006

.CY-O

4x

1,5 mm

M20x1,5 / 12-14,5mm

=11-WG005

&EFS/19.1

=0-GLAND;=11-X2

=MCC

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

Date
Editor
Tested
Changes

Quelle (von)
Source (from)

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Kabelbersicht
Cable layout

Rev.01 =
As built +

Sprache:
Language:

Bemerkung
Remark

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMB

Bl./Sh.
48
67 Bl./Sh.

Klemmenkasten Separator -1X10


Terminal box separator -1X10

Sensorblock -1X20
Sensor bloc -1X20

Verschraubung
Cable gland

Schaltschrank
Control cabinet

+JB-1X10
PE

-X2

PE

+
S
+
-

blue

blue

11

brown

PE

PE

PE

PE

brown

10

PE

Verdraengungs-u. fuellwasser
displacem. a. filling water

P
I

2x0,34mm
-WG202

3x0,75mm
-WG203

PSL/H Reinoel
Ablaufdruck
PSL/H clean oil
discharge pressure
SMS Schlammraumueberwachung
SMS sludge space monitoring

Wasserabfuhr
water monitoring system

grey

2x1,5mm
-WG106

brown

PE

Steuerwasser
operating water

black

2x0,34mm
-WG201

black
white

2x1,5mm
-WG105

black

blue

white

+
blue

brown

PE

19

18

18

-WG122
3x1,5mm
M20 (10-12,5mm)

17

17

16

-WG121
4x1,5mm
M20 (12-14,5mm)

15

16

14

15

+SB-1X20
1

brown

13

14

-WG011
7x1,5mm
M20 (12-14,5mm)

12

13

11

12
2

Drehzahlueberwachung
speed monitoring device

10

11

10

8
+

2x0,34mm
-WG101

blue

-WG004
7x1,5mm
M20 (12-14,5mm)

brown

2
1

PE

3x0,75mm
-WG204

3x0,75mm
-WG205

Kreislaufventil
circulation valve

Wasserabfuhrventil
water discharge valve

2
3

PE

Verschraubung
Cable gland

PE

Bestell-Nr.:0005-1827-280
order-no.:0005-1827-280

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenkasten bersicht
Terminal box overview

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMB

Bl./Sh.
49
67 Bl./Sh.

Hinweise zur Installation von Kabeln und Leitungen


Directions for installation from cables and conductors
*

Schutzmanahmen nach Bestimmungen des VDE bzw. zustndigen EVU ausfhren!


All protective measures are to be taken in accordance with electric codes, rules and regulations!

Generell sind die Vorgaben des lokalen Energieversorgers zwingend einzuhalten


In general the the rules and regulations of the lokal power authorities has to be followed.

Kabel und Leitungen sind so auszuwhlen und zu verlegen, dass eine Gefhrdung von Personen und der Umgebung ausgeschlossen ist.
Die angegebenen Kabelquerschnitte sind bezogen auf eine Kabellnge von 50m, Kupfer als Leitematerial, Verlegeart "C" und
eine maximale Umgebungstemperatur von 30C. Siehe hierzu DIN VDE 0298-4 (Verwendung von Kabeln und isolierten Leitungen fr Starkstromanlagen - Teil 4:
Empfohlene Werte fr die Strombelastbarkeit von Kabeln und Leitungen fr feste Verlegung in und an Gebuden und von flexiblen Leitungen).
Neben der Strombelastung sind bei der Errichtung von Kabel- und Leitungsanlagen weitere Faktoren zu bercksichtigen.
Siehe hierzu IEC 60364-5-52 (Errichten von Niederspannungsanlagen - Teil 5: Auswahl und Errichtung elektrischer Betriebsmittel - Kapitel 52: Kabel- und Leitungsanlagen)
Cables and lines must be selected and laid in a way to eliminate any risk to persons and the environment.
The cable cross-sections specified in these drawings are based on a max. length of 50m, copper as conducting material,laying version "C" and a maximum ambient temperature of 30C.
Refer also to DIN VDE 0298-4 (Usage of cables and cords in power installations - Part 4:
Recommended current-carrying capacity for sheathed and nonsheathed cables for fixed wirings in and around buildings and for flexible cables and cords).
Besides the current load are in the erection of wiring systems additional parameters to take into account.
Refer also to IEC 60364-5-52 (Erection of low voltage installations - Part 5: Selection and erection of electrical equipment - Chapter 52: Wiring systems)

Messleitungen sind grundstzlich abgeschirmt zu verlegen!


Measuring lines must always be laid shielded!

WD-Kabel getrennt vom WF-/WG-Kabeln verlegen!


WD-cables to be installed separate from WF-/WG-cable!

Alle Kabel mssen den Flammentest Anforderungen fr gebndelte Kabel nach IEC 60332-3 / IEEE 45-18.13 gerecht werden.
All cables must meet the flame test requirements for bunched cables acc. to IEC 60332-3 / IEEE 45-18.13.

Das gesamte Kabelmaterial muss halogenfrei nach IEC 60754-1, giftfrei nach IEC 60754 und korrosionsfrei nach IEC 60754-2 sein
All cable materials must be free of halogens acc. to IEC 60754-1, no toxicity acc. to 60754 and no corrosivity acc. to IEC 60754-2.

Alle Kabel mssen eine Abnahme der relevante Abnahmegesellschaft haben. Isolierungsfestigkeit: 0.6/1KV
All cables must have an approval of the relevant classification society. Insulating strength: 0.6/1KV

Date

GEA WSPN Standard: Nexans MPRX 0.6/1kV.

WD-Kabel
WD-cable

Energiekabel < 1kV


Energy cable < 1kV

WE-Kabel
WE-cable

Erdungs-/Potentialausgleichsleiterleiter
Earth-/ Equipotential bonding conductor

WF-Kabel
WF-cable

Datenbus
Data bus

WG-Kabel
WG-cable

Steuer-/ Messkabel
Control-/measuring cable

WH-Kabel
WH-cable

Lichtwellenleiter
Optical fibre

Legende Kabeltypen (Kabelliste)


Legend cable typ (list of cables)

-J

Kabel / Leitung mit Schutzleiter


Cable / conductor with protective conductor

FC.CY

Motorkabel FU mit konzentrischem Auenleiter (PE)


Motor cable FC with concentric outer (PE)

-O

Kabel / Leitung ohne Schutzleiter


Cable / conductor without protective conductor

PL

Potentialausgleichsleiter
Equipotential bonding conductor

CY-J

Kabel / Leitung mit Schutzleiter geschirmt


Cable / conductor with protective conductor screened

Ex-CY

Steuerleitung blau fr eigensichere Stromkreise


Control line blue for intrinsically safecircuits

CY-O

Kabel / Leitung ohne Schutzleiter geschirmt


Cable / conductor without protective conductor screened

CY-TP

Datenleitung paarverseilt
Data line twisted pair

FC.CY-J

Motorkabel FU geschirmt mit Schutzleiter


Motor cable FC screened with protective conductor

Date
Editor
Tested
Changes

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Hinweise zur Installation


Instructions for installation

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMB

Bl./Sh.
50
67 Bl./Sh.

FU
FC

Generelle Information zum Potentialausgleich.


Die Informationen auf diesem Blatt sind nicht
kundenspezifisch angepasst.

=..-U.

IP54

General Information for the equipotential bonding system.


Please note, that the information shown on this page are
not customised.

10 mm
GN YE

PE-Schiene
protective earth - rail

IDM
25 mm
GN YE

10 mm
GN YE

PA

PA1

PA2

PA3

PA4

PA5

PA6

PA7

Potentialausgleichsschiene
equipotential bonding strip

Potentialausgleich Gebude
equipotential bonding building

10 mm
GN YE

25 mm
GN YE

Fundamenterder
foundation earth

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Potentialausgleich Separator
Potential equalization Separator

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMB

Bl./Sh.
51
67 Bl./Sh.

Changes
Date
Name
Date
Editor
Tested
03.03.2011
BEE/PLE
03.02.2011 KA
Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

=100-WG004

SC
SC

GLAND

GLAND

GLAND

GLAND

X
X
X
X
X

SC
SC

MPRXCX 2x1,5 mm

=100-WG004

MPRXCX 2x1,5 mm

=100-WG003

MPRXCX 2x1,5 mm

=100-WG002

MPRXCX 2x1,5 mm

=100-WG001

MPRXCX 2x1,5 mm

-PE

&EFS/21.5

&EFS/21.4

&EFS/21.2

&EFS/21.1

&EFS/19.2

&EFS/18.7

&EFS/18.2

&EFS/16.3

&EFS/14.3

&EFS/13.4

&EFS/13.4

TAL Temperatur Alarm min


TAL temperature alarm min

=100-WG003

SC
SC

TAH Temperatur Alarm max


TAH temperature alarm max

=100-WG002

SC
SC

Wasserschlossalarm
Water seal broken alarm

=100-WG001

GLAND
SC
GLAND

GLAND

-PE

-PE

-PE

-PE

&EFS/12.2

Sammelstrung
Common failure

SC
SC

=11-WG005

=11-WG005

MPRXCX 7x1,5 mm

GLAND

GLAND

=01-WG011

GLAND

Rckmeldung Zulaufpumpe
Feed back feed pump

SC
GLAND

=01+JB-1X10_GLAND

GLAND

MPRXCX 2x1,5 mm

=01-WG010

MPRXCX 7x1,5 mm

GLAND

Wasserabfuhrventil
Water discharge valve

=01-WG010

SC
SC

=01-WG004

MPRXCX 4x1,5 mm

=01-WG009

MPRXCX 2x2,5 mm

=01-WG007

GLAND

-PE

&EFS/10.1

Zulaufventil
Feed valve

=01+JB-1X10_GLAND

SC
SC

Wasserabfuhr
Water monitoring system

SC
SC

=01-WG009

=01-WG007

MPRXCX 2x1,5 mm

=01-WG006

GLAND

-PE
1

Separator Strung
Separator failure

Entleerungsberwachung
Ejection monitoring

=01-WG006

SC
SC

Separator Aus
Separator off

SC
SC
MPRXCX 2x1,5 mm

-WG008

GLAND

Ziel intern
Target intern

MPRXCX 2x2,5 mm

-WD001

Klemmennummer
Terminal number

-WG008

-WD001

Querverweis
Cross reference

Separator Not-Halt
Separator emergency stop

Einspeisung
Incoming

=0+-GLAND
0
5
6

Benennung/Description:

Klemmenanschlussplan =0+-GLAND
Terminal connecting plan =0+-GLAND

Sprache:
Language:

de/en
Zeichnungs Nr.:
Drawing No.:
9

Brcken
Bridges

SC
SC

GLAND

Rev.01 =
As built +

8106-2004-058
DCC

& EMC

Bl./Sh.
52
67 Bl./Sh.

A2

-T2

Klemmennummer
Terminal number

Brcken
Bridges

=0+-24M

Ziel intern
Target intern

BU
13

GN/YE
PE

Name

=01-X2
Steuerspannung DC
Control voltage DC
Date
Editor
Tested
Date

PE

-PE

13

Changes

=01-K1

Querverweis
Cross reference

&EFS/11.6

&EFS/11.6

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =0+-24M
Terminal connecting plan =0+-24M

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMC

Bl./Sh.
53
67 Bl./Sh.

&EFS/23.6

-24M

-PE

-PE

Ziel intern
Target intern

-PE

&EFS/11.6

&EFS/11.6

&EFS/10.6

&EFS/10.6

&EFS/10.6

Querverweis
Cross reference

&EFS/10.5

&EFS/10.3

PE

PE

PE

PE

PE

PE

PE

SC

GN/YE
PE
L

GN/YE
PE

GN/YE
PE

GN/YE
PE

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

PE

PE

Steuergert
Timing unit

-PE
Steuerspannung DC
Control voltage DC

-1G
Erdung Gehuse 1
Earthing cabinet 1

Erdung Tr 1
Earthing door 1

Erdung Montageplatte 1
Earthing mounting plate 1

-1M

-1T

PE

Filterlfter
Filter fan

-M1

-SC
Erdung Schirm
Earthing screen
Changes

PE

M
1~

SC

Date
Editor
Tested

N
N

Klemmennummer
Terminal number

PE

=0+-PE

Brcken
Bridges

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =0+-PE
Terminal connecting plan =0+-PE

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMC

Bl./Sh.
54
67 Bl./Sh.

-SC

Ziel intern
Target intern

-SC

Querverweis
Cross reference

&EFS/20.7

&EFS/10.3

SC

Klemmennummer
Terminal number

SC

=0+-SC

Brcken
Bridges

PE

SC

Date

Name

min / max Temperaturberwachung


Min / max temperature monitoring

Erdung Schirm
Earthing screen
Date
Editor
Tested
Changes

SC

=11-X2

-PE

PE

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =0+-SC
Terminal connecting plan =0+-SC

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMC

Bl./Sh.
55
67 Bl./Sh.

&EFS/10.5

&EFS/10.5

-S1

23

&EFS/10.4

&EFS/10.4
-S1

13

-F1

Ziel intern
Target intern

-F1

Querverweis
Cross reference

&EFS/10.1

&EFS/10.1

2
2

RD
L

RD/WH
PE

-WD001
1
L1

MPRXCX 2x2,5 mm

Klemmennummer
Terminal number

=0+-X1

Brcken
Bridges

PE

M
1~

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Filterlfter
Filter fan

Reserve
Spare

Einspeisung
Incoming

-M1

=Customer+L-X

L1

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =0+-X1
Terminal connecting plan =0+-X1

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMC

Bl./Sh.
56
67 Bl./Sh.

=MCC-X

Ziel intern
Target intern

=MCC-X

Querverweis
Cross reference

&EFS/12.1

&EFS/12.1

2
-WG008

MPRXCX 2x1,5 mm

Klemmennummer
Terminal number

=0+-X2

Brcken
Bridges

Date
Editor
Tested
Changes

Date

Name

Separator Not-Halt
Separator emergency stop

=MCC-X

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =0+-X2
Terminal connecting plan =0+-X2

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMC

Bl./Sh.
57
67 Bl./Sh.

-T1
-WG007

MPRXCX 2x2,5 mm

Klemmennummer
Terminal number

Brcken
Bridges

=01+-X1

Ziel intern
Target intern

-T1

Querverweis
Cross reference

&EFS/13.4

&EFS/13.4

Date
Editor
Tested
Changes

Date

Name

Entleerungsberwachung
Ejection monitoring

=MCC-X_

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =01+-X1
Terminal connecting plan =01+-X1

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMC

Bl./Sh.
58
67 Bl./Sh.

Changes
Date
Editor
Tested

Date
Name
03.03.2011
BEE/PLE
03.02.2011 KA
Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

2
12
3
15

7
4
16
5
18
6
17

Benennung/Description:

Klemmenanschlussplan =01+-X2
Terminal connecting plan =01+-X2

3
MPRXCX 4x1,5 mm

-WG009

MPRXCX 7x1,5 mm

-WG011

21

20

19

18

17

16

15

14

13

12

11

10

=00-K1

=00-K1

=00-K1

=00-K1

=00-K1

=00-K1

=0-24M

=00-K1

=00-K1

=00-K1

=11-X2

=00-K1

X11:2

X11:1

X12:6

X12:5

X12:2

X12:3

X12:1

X11:16

X11:6

X13:8

&EFS/14.2

&EFS/14.1

&EFS/18.7

&EFS/18.6

&EFS/18.5

&EFS/18.4

&EFS/18.4

&EFS/18.3

&EFS/18.1

&EFS/18.1

&EFS/17.4

&EFS/16.3

&EFS/16.3

&EFS/16.2

&EFS/16.2

&EFS/16.1

&EFS/16.1

Separator Strung
Separator failure

=MCC

Separator Betrieb
Separator operation

Wasserabfuhrventil
Water discharge valve

+
MPRXCX 2x1,5 mm

-WG010

MPRXCX 7x1,5 mm

-WG011

MPRXCX 7x1,5 mm

-WG004

MPRXCX 4x1,5 mm

-WG009

X13:5

&EFS/15.2

&EFS/15.2

&EFS/13.4

Kreislaufventil
Circulation valve

6
1
10

Verdrngungs- und Fllwasser


Displacem- and filling water

+JB-1X10

Steuerwasser
Operating water

1
MPRXCX 7x1,5 mm

-WG004

=00-K1

=0-X2

2-

1+

12

&EFS/13.4

-*8_7_002

Zulaufventil
Feed valve

Reserve
Spare

+JB-1X10

Wasserabfuhr
Water monitoring system

=MCC

4
MPRXCX 4x1,5 mm

-WG009

-T2

-T2

-K1

11

Separator Strung
Separator failure

+JB-1X10

Schlammraumberwachung
Sludge space monitoring

=MCC

1
MPRXCX 7x1,5 mm

-WG004

-K1

Separator Betrieb
Separator operation

Reinoel Ablaufdruck
Clean-oil discharge pressure

+JB-1X10

MPRXCX 2x1,5 mm

-WG006

Klemmennummer
Terminal number
1

Ziel intern
Target intern

Drehzahlberwachung
Speed monitoring device

=MCC-X_

Querverweis
Cross reference

Separator Aus
Separator off

=01+-X2
0
6
7

Sprache:
Language:

de/en
Zeichnungs Nr.:
Drawing No.:
9

Brcken
Bridges

12

Rev.01 =
As built +

8106-2004-058
DCC

& EMC

Bl./Sh.
59
67 Bl./Sh.

Changes
Date
Name
Date
Editor
Tested
03.03.2011
BEE/PLE
03.02.2011 KA
Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

1
+
2
8
1

1
MPRXCX 3x1,5 mm

-WG122

MPRXCX 2x1,5 mm

-WG106

2
10

PE

18

17

16

15

14

13

-PE

-X2

-X2

-X2

-X2

-X2

-X2

-X2

-X2

18

19

17

15

14

11

10

&EFS/18.4

&EFS/18.6

&EFS/18.7

&EFS/18.5

&EFS/18.4

&EFS/18.4

&EFS/18.3

&EFS/18.3

&EFS/17.1

&EFS/17.4

&EFS/17.3

&EFS/17.1

&EFS/16.3

&EFS/16.2

&EFS/16.1

&EFS/16.1

&EFS/16.1

&EFS/15.2

&EFS/15.2

Verdrngungs- und Fllwasser


Displacem- and filling water

Wasserabfuhrventil
Water discharge valve

+SB-1X20

Kreislaufventil
Circulation valve

4
MPRXCX 2x1,5 mm

-WG105

12

11

10

-X2

-X2

-X2

-*9_7_005

Verdrngungs- und Fllwasser


Displacem- and filling water

-*9_7_004

Steuerwasser
Operating water

2
MPRXCX 4x1,5 mm

-X2

Reserve
Spare

BU

Wasserabfuhr
Water monitoring system

Schlammraumberwachung
Sludge space monitoring

BN

-WG121

.-O 2x0,34 mm

-WG101

&EFS/16.4

&EFS/18.3

+SB-1X20

Reinoel Ablaufdruck
Clean-oil discharge pressure

-*0_9_020

-PE

Ziel intern
Target intern

Drehzahlberwachung
Speed monitoring device

PE

Klemmennummer
Terminal number
PE

Querverweis
Cross reference

Wasserabfuhr
Water monitoring system

Steuerwasser
Operating water

=01+JB-1X10
0
5
6

Benennung/Description:

Klemmenanschlussplan =01+JB-1X10
Terminal connecting plan =01+JB-1X10

Sprache:
Language:

de/en
Zeichnungs Nr.:
Drawing No.:
9

Brcken
Bridges

3
11

Rev.01 =
As built +

8106-2004-058
DCC

& EMC

Bl./Sh.
60
67 Bl./Sh.

&EFS/18.4

&EFS/18.3

=0-GLANDGLAND

=0-GLANDGLAND

Ziel intern
Target intern

-WG106

SC
SC

SC
SC

PE

SC
SC
PE:PE PE:PE

MPRXCX 2x1,5 mm

GLAND

MPRXCX 2x1,5 mm

GLAND

-WG105

MPRXCX 3x1,5 mm

GLAND
-WG122

Klemmennummer
Terminal number

MPRXCX 4x1,5 mm

GLAND

Brcken
Bridges

-WG121

=01+JB-1X10_GLAND

Querverweis
Cross reference

&EFS/18.7

&EFS/16.3

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

-WG106
Verdrngungs- und Fllwasser
Displacem- and filling water

Steuerwasser
Operating water

Wasserabfuhrventil
Water discharge valve

Wasserabfuhr
Water monitoring system

-WG105

+SB-1X20

PE

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =01+JB-1X10_GLAND
Terminal connecting plan =01+JB-1X10_GLAND

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMC

Bl./Sh.
61
67 Bl./Sh.

Changes
Date
Name
Date
Editor
Tested
03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

P
-

BN
+
BU

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

PE

-*0_7_011

BU

PE

PE

PE

11

X
X

PE
PE

GEA Westfalia
Separator

.-J 3x0,75 mm

-WG205

.-J 3x0,75 mm

-WG204

.-J 3x0,75 mm

-WG205

10

18

17

16

+JB-1X10_GLAND
GLAND

+JB-1X10_GLAND
GLAND

+JB-1X10

+JB-1X10

+JB-1X10

+JB-1X10

+JB-1X10

&EFS/18.7

&EFS/18.6

&EFS/18.6

&EFS/18.7

&EFS/18.5

&EFS/18.5

&EFS/16.3

&EFS/16.3

&EFS/16.3

&EFS/16.2

&EFS/16.2

&EFS/16.1

&EFS/16.1

Wasserabfuhrventil
Water discharge valve

-*0_7_010

BN

Kreislaufventil
Circulation valve

-*0_7_011

GY
.-J 3x0,75 mm

-WG204

.-O 3x0,75 mm

+JB-1X10

Wasserabfuhrventil
Water discharge valve

BN

Kreislaufventil
Circulation valve

BK
A/Q

-WG203

.-O 2x0,34 mm

-WG202

+JB-1X10

BK

A/Q

WH

-*0_7_010

-*0_9_013

BK

Wasserabfuhr
Water monitoring system

WH

-*0_9_014

2
.-O 2x0,34 mm

-WG201

Klemmennummer
Terminal number

Ziel intern
Target intern

Schlammraumberwachung
Sludge space monitoring

-*1_9_002

Querverweis
Cross reference

Reinoel Ablaufdruck
Clean-oil discharge pressure

=01+SB-1X20
0
4
5

Benennung/Description:

Klemmenanschlussplan =01+SB-1X20
Terminal connecting plan =01+SB-1X20

6
7

Sprache:
Language:

de/en
Zeichnungs Nr.:
Drawing No.:
9

Brcken
Bridges

PE
PE

Rev.01 =
As built +

8106-2004-058
DCC

& EMC

Bl./Sh.
62
67 Bl./Sh.

&EFS/21.5

-K4

14

&EFS/21.5
-K4

11

&EFS/21.4
-K3

14

&EFS/21.3
-K3

11

&EFS/21.2
-K2

14

&EFS/21.2
11
-K2

14

-K1

8
-WG004

MPRXCX 2x1,5 mm

6
-WG003

MPRXCX 2x1,5 mm

4
MPRXCX 2x1,5 mm

3
2

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

TAL Temperatur Alarm min


TAL temperature alarm min

TAH Temperatur Alarm max


TAH temperature alarm max

Wasserschlossalarm
Water seal broken alarm

Sammelstrung
Common failure

=Customer+L-X

-WG002

-WG001

MPRXCX 2x1,5 mm

Klemmennummer
Terminal number

Brcken
Bridges

=100+-X2

Ziel intern
Target intern

-K1

11

Querverweis
Cross reference

&EFS/21.1

&EFS/21.1

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =100+-X2
Terminal connecting plan =100+-X2

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMC

Bl./Sh.
63
67 Bl./Sh.

&EFS/20.7

SC

&EFS/20.6

=0-SC

=00-K1

X13:16

&EFS/20.6

=MCC

=MCC

SC

5
2

3
3

4
4

.CY-O 4x1,5 mm

-WG003

-WG005

MPRXCX 2x1,5 mm

Klemmennummer
Terminal number

Brcken
Bridges

=11+-X2

Ziel intern
Target intern

=00-K1

X13:15

&EFS/20.5

&EFS/20.5

Querverweis
Cross reference

&EFS/19.1

&EFS/19.1

Date
Editor
Tested
Changes

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

min / max Temperaturberwachung


Min / max temperature monitoring

min / max Temperaturberwachung


Min / max temperature monitoring

Reserve
Spare

Rckmeldung Zulaufpumpe
Feed back feed pump

-*0_9_006

=MCC

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =11+-X2
Terminal connecting plan =11+-X2

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EMC

Bl./Sh.
64
67 Bl./Sh.

Stckliste
Parts list
Funktionszeichen
Function sign

/Seite.Pfad
/page.path

Bezeichnung
Name

Hersteller
Manufacturer

=0-F1

&EFS/10.1

0005-1551-010

Sicherungsautomat , C 6A , 2 pol

AEG

=0-M1

&EFS/10.4

0005-1409-320

Filterlfter, 207-253V, 50/60Hz, 19/18W, 44/52m/h, IP54, RAL 7035

Pfannenberg

=0-M1

&EFS/10.4

0005-1409-230

Austrittsfilter

Pfannenberg

=0-S1

&EFS/10.1

0005-1439-000

Schwenksteller komplett, rastend, rot, 0-I, 1x 2NO + 1x1NC

Plenge

=0-X1

&EFS/10.1

2002-1201

2-Leiter-Durchgangsklemme 0,08-2,5mm

Wago

=0-24M

&EFS/11.6

1031400000

Durchgangs-Reihenklemme, 1,5 mm, Schraubanschluss, Wemid, dunkelbeige, TS 35

Weidmueller

=0-P1

&EFS/11.8

0005-4396-040

VORSATZ, RUND LEUCHTMELDER LINSE WEISS MIT HALTER

Siemens

=0-P1

&EFS/11.8

3SB3400-1RE

LAMPENFASSUNG MIT INTEGRIERTER LED, AC 230V, WEISS

Siemens

=0-P1

&EFS/11.8

3SB3922-0AV

SCHILDTRAEGER FLACH, FUER BEZEICHNUNGSSCHILD 12,5 X 27MM

Siemens

=0-P1

&EFS/11.8

3SB1901-2AA

BEZEICHNUNGSSCHILD, SILBERFARBEN, FR SELBSTBESCHRIFTUNG, 12,5x27MM

Siemens

=0-T2

&EFS/11.5

0005-1407-020

Einphasennetzgeraet Prim.: 120/230V, 50/60Hz, Sec.: 24VDC, 5A

Siemens

=0-X2

&EFS/12.1

2002-1201

2-Leiter-Durchgangsklemme 0,08-2,5mm

Wago

=01-T1

&EFS/13.5

0005-3482-070

Stromberwachung, 0...1 A AC/ 0...5 A AC/ 0...10 A AC , 1 , 0(4)...20 mA , 0...10 V , 1 Schraubanschluss

Weidmueller

=01-X1

&EFS/13.4

2002-1201

2-Leiter-Durchgangsklemme 0,08-2,5mm

Wago

=01-X2

&EFS/13.4

2002-1201

2-Leiter-Durchgangsklemme 0,08-2,5mm

Wago

=01-K1

&EFS/14.4

0005-4033-040

Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 VDC

Phoenix Contakt

=01-T2

&EFS/15.1

0005-4509-000

Sensor-Endstufenklemme, Eingang fr NAMUR-Sensoren, 24V DC Speisespannung

Pepperl & Fuchs

=11-X2

&EFS/19.1

2002-1201

2-Leiter-Durchgangsklemme 0,08-2,5mm

Wago

=100-K1

&EFS/21.1

0005-4033-040

Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 VDC

Phoenix Contakt

Date
Editor
Tested
Changes

Bestell-Nr.
Order no..

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Stckliste
Parts list

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EPB

Bl./Sh.
65
67 Bl./Sh.

Stckliste
Parts list
Funktionszeichen
Function sign

/Seite.Pfad
/page.path

Bezeichnung
Name

Hersteller
Manufacturer

=100-K2

&EFS/21.2

0005-4033-040

Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 VDC

Phoenix Contakt

=100-K3

&EFS/21.3

0005-4033-040

Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 VDC

Phoenix Contakt

=100-K4

&EFS/21.5

0005-4033-040

Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 VDC

Phoenix Contakt

=100-X2

&EFS/21.1

2002-1201

2-Leiter-Durchgangsklemme 0,08-2,5mm

Wago

=00-K1

&EFS/23.1

0005-4050-430

Komplettgert GEA, C7-613, 24DE/16DA/5AE/2AA, SIMATIC C7

Siemens

-Cabinet

&ELU/27.1

1338500

Kompakt-Schaltschrank AE, lackiert RAL 7035, mit Montageplatte, eintrig

Rittal

-Cabinet

&ELU/27.1

2508000

Wandbefestigungshalter Stahlblech, Wandabstand 10mm

Rittal

-Cabinet

&ELU/27.1

0005-1412-000

Trarretierung fr das AE Programm

Rittal

-Cabinet

&ELU/27.1

2510000

Schaltplantaschen aus Kunststoff Din A4

Rittal

-Cabinet

&ELU/27.1

Lack_AE1030-1338

Lackierung

Plenge

-Cabinet

&ELU/27.1

8556-9999-000

Kleinmaterial Schaltschrank

Plenge

-Cabinet

&ELU/27.1

RESOPALSCHILD100/130

Resopalschild

Kaiser

-Cabinet

&ELU/27.1

4568000

Transportsen fr PS/ES und TS

Rittal

-Cabinet

&ELU/27.1

ADERKENNZEICHNUNG

Aderkennzeichnung

Plenge

-Cabinet

&ELU/27.1

Halogenfreie Kanle

Plenge

-Cabinet

&ELU/27.1

Halogenfreie Verdrahtung

Plenge

-Ground_plate

&ELU/28.1

0005-4515-600

Verschraubung, Z12-A6A, 10-12,5mm

Heinrich

-Ground_plate

&ELU/28.1

0005-4516-600

Verschraubung, Z14, 12-14,5mm

Heinrich

-Ground_plate

&ELU/28.1

0005-4443-630

Blindstopfen Messing, M20x1,5

Jacob

Date
Editor
Tested
Changes

Bestell-Nr.
Order no..

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Stckliste
Parts list

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EPB

Bl./Sh.
66
67 Bl./Sh.

Stckliste
Parts list
Funktionszeichen
Function sign

/Seite.Pfad
/page.path

Bezeichnung
Name

Hersteller
Manufacturer

-Ground_plate

&ELU/28.1

22-20-02-2

EMV-Gegenmutter M20/EMV

Heinrich

=Additions

&ELU/28.8

0005-1554-000

Kabelbezeichnung, polyamid

Weidmueller

=Additions

&ELU/28.8

8555-9001-010

Betriebsanleitung D10 NewDesign, englisch

WS Mineraloil Systems

=Additions-S01

&ELU/30.1

0005-0081-030

Pilzdrucktaster Gehuse, verrastend, mit Schutzkragen, 1NC, 2x M20

Siemens

=Additions-S01

&ELU/30.1

0005-4515-600

Verschraubung, Z12-A6A, 10-12,5mm

Heinrich

=Additions-S01

&ELU/30.1

22-20-02-2

EMV-Gegenmutter M20/EMV

Heinrich

=Additions-B1

&ELU/31.2

0005-0924-220

Stromwandler, 50/1A

IME

=Additions-F1

&ELU/32.2

0005-1100-070

THERMISTOR-MOTORSCHUTZ, STANDARD-AUSWERTEGERT, AUTO, 1S+1OE, AC 230V

Siemens

Date
Editor
Tested
Changes

Bestell-Nr.
Order no..

Date

Name

03.03.2011
BEE/PLE
03.02.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.

Benennung/Description:

Stckliste
Parts list

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-058

& EPB

Bl./Sh.
67
67 Bl./Sh.

Contents
3.

LO
Data sheet
P&ID
Equipment list
Dimensioned drawing
Detail drawings:

2064-4100-000

3/2-Way feed valve

9901-8105-440

Dimensioned drawing for motor

9901-8105-305

Starting characteristics

9997-0142-020

Circuit diagram

8106-2004-059

Commissioning equipment, spare parts and tools list

GEA Westfalia Separator Systems GmbH

Process Condition Data Sheet


Manufacurer:
Customer:
Hull No.:
Classification:

DSME
43223
44608
ABS

Project No.:

Oil to be Processed
Application:
Viscosity:
Density:
Inlet Temperature:
Separating Temperature:
Effec.throughput capacity:
Ambient Conditions
Ambient Temperature:
Humidity:
Atmospheric Pressure:
Separator
Type:
Operation Mode:
Ejection Method:
Clean Oil Discharge:
Finish color:
Total weight:
Bowl speed
Bowl weight
Control Unit
Type:
Infeed voltage:
Frequency:
Valve Voltage:
Control Voltage:
Finish Color:
Weight:

Rev. No. 0

H1195
H1196

HD Oil

30
1,01
50
90
3.000

SAE
g/ml 15C
C
C
l/h

IMO No.:

WS Order No:

Drawing No.:

P452946646-9913-PDS010

Operating Water
Hardness:
Chloride Ions:
PH - Value:
Temperature:
Feed Pressure:
Required Capacity:
Consumption / Ejection:

45 C

up to 92%
up to 1000 m Above Sea Level
2 x OSE 20-0196-067/15
total
1,5
Munsell 7.5 BG 7/2
320
12000
71
D 10
440
60
24
230
Munsell 7.5 BG 7/2
55

bar g
kg
rpm
kg
Volt
Hz
DC
Volt
kg

< 55C 12 dH
> 55C 6 dH
< 100 mg/l
6,5 - 7,5
+10C up to +85C
3-10 bar (min.3bar)
0,5 l/s
3-4 l

Compressed Air
Pressure:
7
Standard operating compressed air
Min. 3 bar / max. 10 bar
Separator Motor
Type:
Frame size 132
Voltage:
440
Frequency:
60
Output:
8,6
Speed:
3600
Weight:
48
Feed Pump
Type:
Rated Capacity:
Suction Height:
Delivery Height:
Voltage:
Frequency:
Output:
Weight:
Set Points

bar

Volt
Hz
kW
rpm
kg

l/h
m Ws
m Ws
440 Volt
60 Hz
kW
kg

Adjustment
Inlet Temperature Controler TC

ID No.
*0-9-007

Inlet Temperature Alarm high TAH

*0-9-006

100 C

Inlet Temperature Alarm low TAL

*0-9-006

80 C

Water Pressure Reducer PCV

*9-7-003

3 -10 bar g

Pressure Alarm low PAL Clean Oil Discharge

*1-9-002

1 bar

Pressure Switch PSL Sludge Monitoring System

*1-9-003

1 bar for -91-/0136 0,5 bar for -0196-

Subject to technical modification

452946646
452946721

90 C

26.10.2010

Customer: DSME

Project-/Order-No.:

43223 / 452946646

Location:

Project-title:

OSE 20-0196

H1195/H1196

GEA Westfalia Separator

Equipment List

Order-No.:

452946646

Project - title:

OSE 20-0196

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Date: 05.12.2011

Dept.: 4420

Type:

Corr. Drawing: P452946646-9913-PID010

Belongs to:

Repl for: ---

Repl. by: ---

Std. checked: ---

Explanations:
Priority(A):

Procurement (B):

Scope of supply (C):

N = Obligatory
E = Recommended
P = Possible
U = ---

M = Must be obtained from Westfalia


K = May be obtained from Westfalia
Z = Supplied by client
V = ---

L = Scope of supply by WS
S = Supplied by client
F = to be removed
W = loose supply

Created Date: 04.10.2010

Checked Date:

Approved Date:

Document No.:

By:

By:

By:

P452946646-9913-DVL010

4110-NIE.

Copyright. All rights reserved

Revison:

Page:
1/3

Customer: DSME

Project-/Order-No.:

43223 / 452946646

Location:

Project-title:

OSE 20-0196

H1195/H1196

GEA Westfalia Separator

Equipment List
ID

Quantity

Description
Usage

Size/Type
Nominal Bore

10-1-001

1 Stck

Separator

10-1-001/M1

1 Stck

Motor

10-7-005

1 Stck

Throttle Valve

Power

Part-No.

OSE 20-0196-067

Frame size 132

belongs to *0-7-006

0018-7621-110

Comments
PID Code

DN25
10-7-006

1 Stck

3/2-Way Feed Valve Assembly


DN25

10-7-010

1 Stck

2/2 Way Solenoid Valve

0331

0018-8133-600

10-7-011

1 Stck

2/2 Way Solenoid Valve

0331

0018-8133-600

10-7-012

1 Stck

Pressure Gauge Cock

belongs to *0-1-001

TE

belongs to *0-7-006

1/4"
10-9-006

1 Stck

Resistance Thermometer

10-9-009

1 Stck

Flow Sensor

FI

0001-1701-600

10-9-010

1 Stck

Resistance Thermometer

TE

installed in Motor

10-9-011

1 Stck

Current Transformer

TAI 233

IAL

0005-0924-220

10-9-013

1 Stck

Water Detector

SK1-HT125-LO

CS

0005-1464-060

10-9-014

1 Stck

Pressure Transmitter

NAE
1/4"

PT

0005-1529-300

10-9-018

1 Stck

Proximity sensor

SIS

0005-0868-000

11-7-001

1 Stck

Non-Return Valve

0018-2990-650

2 x PT 100
1/2"

1"

Created Date: 04.10.2010

Checked Date:

Approved Date:

Document No.:

By:

By:

By:

P452946646-9913-DVL010

4110-NIE.

Copyright. All rights reserved

Revison:

Page:
2/3

Customer: DSME

Project-/Order-No.:

43223 / 452946646

Location:

Project-title:

OSE 20-0196

H1195/H1196

GEA Westfalia Separator

Equipment List
ID

Quantity

Description
Usage

11-7-003

1 Stck

Pressure Gauge Cock

Size/Type
Nominal Bore

Power

Part-No.

belongs to *0-1-001

Comments
PID Code

1/4"
11-9-001

1 Stck

Pressure Gauge

213.40 / 0..40bar
1/4"

PI

0001-1572-600

11-9-002

1 Stck

Pressure Transmitter

NAE
1/4"

PT

0005-1529-300

12-7-001

1 Stck

Non-Return Flap

belongs to *0-7-006

belongs to *0-7-006

0018-1763-630/belongs
to *9-7-003

0018-7614-000

belongs to *9-7-003

belongs to *9-7-003

belongs to *9-7-003

0001-1572-600/belongs
to *9-7-003

DN 25
18-7-002

1 Stck

Solenoid Valve
1/4"

19-7-002

1 Stck

Ball Valve
3/4"

19-7-003

1 Stck

Solenoid Valve Assembly compl.


3/4"

19-7-004

1 Stck

2/2-Way Solenoid Valve


1/2"

19-7-005

1 Stck

2/2-Way Solenoid Valve


1/4"

19-8-001

1 Stck

Y-Strainer
3/4"

19-9-001

1 Stck

Pressure Gauge

213.40 / 0..10bar

PI

Created Date: 04.10.2010

Checked Date:

Approved Date:

Document No.:

By:

By:

By:

P452946646-9913-DVL010

4110-NIE.

Copyright. All rights reserved

Revison:

Page:
3/3

GEA Westfalia Separator


Werner-Habig-Str. 1 - 59302 Oelde ( Germany ) - Phone +49 2522 77-0

Kunde
Customer

: -

Anlagenbezeichnung
Designation of plant

: -

Zeichnungsnummer
Drawing no.

: 8106-2004-059

Kommission
Internal order no.

: -

Hersteller (Firma)
Manufacturer (Company)

: GEA Westfalia Separator

Projektname
Name of project

: -

Typ
Type

: D10 / OSE 20-0196

Sprache
Language

: de/en

Technische Daten
Technical data

: 230V AC

Erstellt am
Prepared

: 07.10.2010

GEA Projektsachbearbeiter : M. Kalb


GEA project contact
Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

60 Hz

Bearbeitet am
Processed

: 04.03.2011

Telefon
Telephone

: +49 2522 77-2802

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

+/-5 %

Benennung/Description:

Titel- / Deckblatt
Title- / cover sheet

Angewandte Normen:
Applied standards:

Rev.01 =
As built +

Sprache:
Language:

IEC 61346
IEC 61355
IEC 60617

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EAA

Bl./Sh.
1
67 Bl./Sh.

Inhaltsverzeichnis
Table of contents
Dokumentenart
Document type

Seite
Page

Date

Anlage
Plant

Einbauort
Mounting place

Datum
Date

Bearbeiter
Editor

&EAA

Titel- / Deckblatt
Title- / cover sheet

04.03.2011

GRO/PLE

&EAB

Inhaltsverzeichnis
Table of contents

04.03.2011

GRO/PLE

&EAB

Inhaltsverzeichnis
Table of contents

04.03.2011

GRO/PLE

&EAB

Inhaltsverzeichnis
Table of contents

04.03.2011

GRO/PLE

&EAB

Inhaltsverzeichnis
Table of contents

04.03.2011

GRO/PLE

&EBH

Revisionsbersicht
Revision overview

04.03.2011

GRO/PLE

&EDB

Strukturkennzeichenbersicht
Structure indicator

04.03.2011

GRO/PLE

&EDB

Informations-Blatt
Information-sheet

04.03.2011

GRO/PLE

&EDB

Informations-Blatt
Information-sheet

04.03.2011

GRO/PLE

&EFS

10

Einspeisung
Incoming

=0

04.03.2011

GRO/PLE

&EFS

11

Steuerspannung 24VDC
Control voltage 24VDC

=0

04.03.2011

GRO/PLE

&EFS

12

Not-Halt
Emergency stop

=0

04.03.2011

GRO/PLE

&EFS

13

Separator
Separator

=01

04.03.2011

GRO/PLE

&EFS

14

Separator
Separator

=01

04.03.2011

GRO/PLE

&EFS

15

Separator Drehzahlmessung
Separator speed measuring

=01

04.03.2011

GRO/PLE

&EFS

16

Separator Signale
Separator signals

=01

04.03.2011

GRO/PLE

&EFS

17

Separator Vibro
Separator vibro

=01

04.03.2011

GRO/PLE

&EFS

18

Separator Ventile
Separator valves

=01

04.03.2011

GRO/PLE

&EFS

19

Freigabe Produkt Temperaturregelung


Release product temperature control

=11

04.03.2011

GRO/PLE

Date
Editor
Tested
Changes

Seitenbeschreibung
Page description

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Inhaltsverzeichnis
Table of contents

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EAB

Bl./Sh.
2
67 Bl./Sh.

Inhaltsverzeichnis
Table of contents
Dokumentenart
Document type

Seite
Page

Date

Anlage
Plant

Einbauort
Mounting place

Datum
Date

Bearbeiter
Editor

&EFS

20

Produkt Temperaturregelung
Product temperature control

=11

04.03.2011

GRO/PLE

&EFS

21

Signalaustausch
Signal exchange

=100

04.03.2011

GRO/PLE

&EFS

22

SPS bersicht
PLC overview

=00

04.03.2011

GRO/PLE

&EFS

23

SPS Spannungsversorgung
PLC power supply

=00

04.03.2011

GRO/PLE

&EFS

24

SPS bersicht
PLC overview

=00

04.03.2011

GRO/PLE

&EFS

25

SPS bersicht
PLC overview

=00

04.03.2011

GRO/PLE

&EFS

26

SPS bersicht
PLC overview

=00

04.03.2011

GRO/PLE

&ELU

27

Aufbauplan
Arrangement drawing

04.03.2011

GRO/PLE

&ELU

28

Aufbauplan
Arrangement drawing

04.03.2011

GRO/PLE

&ELU

29

D10
D10

04.03.2011

GRO/PLE

&ELU

30

Not-Halt-Box
Energency stop box

04.03.2011

GRO/PLE

&ELU

31

Stromwandler
Current transformer

04.03.2011

GRO/PLE

&ELU

32

Motorvollschutzrelais
Motor protection relay

04.03.2011

GRO/PLE

&EMA

33

Klemmenplan =0+-GLAND
Terminal connection diagram =0+-GLAND

=0

04.03.2011

GRO/PLE

&EMA

34

Klemmenplan =0+-GLAND
Terminal connection diagram =0+-GLAND

=0

04.03.2011

GRO/PLE

&EMA

35

Klemmenplan =0+-24M
Terminal connection diagram =0+-24M

=0

04.03.2011

GRO/PLE

&EMA

36

Klemmenplan =0+-PE
Terminal connection diagram =0+-PE

=0

04.03.2011

GRO/PLE

&EMA

37

Klemmenplan =0+-SC
Terminal connection diagram =0+-SC

=0

04.03.2011

GRO/PLE

&EMA

38

Klemmenplan =0+-X1
Terminal connection diagram =0+-X1

=0

04.03.2011

GRO/PLE

Date
Editor
Tested
Changes

Seitenbeschreibung
Page description

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Inhaltsverzeichnis
Table of contents

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EAB

Bl./Sh.
3
67 Bl./Sh.

Inhaltsverzeichnis
Table of contents
Dokumentenart
Document type

Seite
Page

Date

Anlage
Plant

Einbauort
Mounting place

Datum
Date

Bearbeiter
Editor

&EMA

39

Klemmenplan =0+-X2
Terminal connection diagram =0+-X2

=0

04.03.2011

GRO/PLE

&EMA

40

Klemmenplan =01+-X1
Terminal connection diagram =01+-X1

=01

04.03.2011

GRO/PLE

&EMA

41

Klemmenplan =01+-X2
Terminal connection diagram =01+-X2

=01

04.03.2011

GRO/PLE

&EMA

42

Klemmenplan =01+JB-1X10
Terminal connection diagram =01+JB-1X10

=01

+JB

04.03.2011

GRO/PLE

&EMA

43

Klemmenplan =01+JB-1X10_GLAND
Terminal connection diagram =01+JB-1X10_GLAND

=01

+JB

04.03.2011

GRO/PLE

&EMA

44

Klemmenplan =01+SB-1X20
Terminal connection diagram =01+SB-1X20

=01

+SB

04.03.2011

GRO/PLE

&EMA

45

Klemmenplan =100+-X2
Terminal connection diagram =100+-X2

=100

04.03.2011

GRO/PLE

&EMA

46

Klemmenplan =11+-X2
Terminal connection diagram =11+-X2

=11

04.03.2011

GRO/PLE

&EMB

47

Kabelbersicht
Cable layout

04.03.2011

GRO/PLE

&EMB

48

Kabelbersicht
Cable layout

04.03.2011

GRO/PLE

&EMB

49

Klemmenkasten bersicht
Terminal box overview

04.03.2011

GRO/PLE

&EMB

50

Hinweise zur Installation


Instructions for installation

04.03.2011

GRO/PLE

&EMB

51

Potentialausgleich Separator
Potential equalization Separator

04.03.2011

GRO/PLE

&EMC

52

Klemmenanschlussplan =0+-GLAND
Terminal connecting plan =0+-GLAND

04.03.2011

GRO/PLE

&EMC

53

Klemmenanschlussplan =0+-24M
Terminal connecting plan =0+-24M

04.03.2011

GRO/PLE

&EMC

54

Klemmenanschlussplan =0+-PE
Terminal connecting plan =0+-PE

04.03.2011

GRO/PLE

&EMC

55

Klemmenanschlussplan =0+-SC
Terminal connecting plan =0+-SC

04.03.2011

GRO/PLE

&EMC

56

Klemmenanschlussplan =0+-X1
Terminal connecting plan =0+-X1

04.03.2011

GRO/PLE

&EMC

57

Klemmenanschlussplan =0+-X2
Terminal connecting plan =0+-X2

04.03.2011

GRO/PLE

Date
Editor
Tested
Changes

Seitenbeschreibung
Page description

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Inhaltsverzeichnis
Table of contents

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EAB

Bl./Sh.
4
67 Bl./Sh.

Inhaltsverzeichnis
Table of contents
Dokumentenart
Document type

Seite
Page

Date

Anlage
Plant

Einbauort
Mounting place

Datum
Date

Bearbeiter
Editor

&EMC

58

Klemmenanschlussplan =01+-X1
Terminal connecting plan =01+-X1

04.03.2011

GRO/PLE

&EMC

59

Klemmenanschlussplan =01+-X2
Terminal connecting plan =01+-X2

04.03.2011

GRO/PLE

&EMC

60

Klemmenanschlussplan =01+JB-1X10
Terminal connecting plan =01+JB-1X10

04.03.2011

GRO/PLE

&EMC

61

Klemmenanschlussplan =01+JB-1X10_GLAND
Terminal connecting plan =01+JB-1X10_GLAND

04.03.2011

GRO/PLE

&EMC

62

Klemmenanschlussplan =01+SB-1X20
Terminal connecting plan =01+SB-1X20

04.03.2011

GRO/PLE

&EMC

63

Klemmenanschlussplan =100+-X2
Terminal connecting plan =100+-X2

04.03.2011

GRO/PLE

&EMC

64

Klemmenanschlussplan =11+-X2
Terminal connecting plan =11+-X2

04.03.2011

GRO/PLE

&EPB

65

Stckliste
Parts list

04.03.2011

GRO/PLE

&EPB

66

Stckliste
Parts list

04.03.2011

GRO/PLE

&EPB

67

Stckliste
Parts list

04.03.2011

GRO/PLE

Date
Editor
Tested
Changes

Seitenbeschreibung
Page description

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Inhaltsverzeichnis
Table of contents

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EAB

Bl./Sh.
5
67 Bl./Sh.

Revisionsbersicht
Revision overview
Revisionsname
Revision name

Revisionskommentar
Revision comment

Rev.01

As built

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Revisionsnderungsgrund
Revision on the basis of change

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Revisionsbersicht
Revision overview

Seitenname
Page name

Ersteller
Author

Datum
Date

GRO/PLE

04.03.2011

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EBH

Bl./Sh.
6
67 Bl./Sh.

Strukturkennzeichenbersicht
Structure indicator
Vollstndige Bezeichnung
Complete name

Dokumentenart
Document type
Dokumentenart
Document type
Dokumentenart
Document type
Dokumentenart
Document type
Dokumentenart
Document type
Dokumentenart
Document type
Dokumentenart
Document type
Dokumentenart
Document type
Dokumentenart
Document type
Dokumentenart
Document type
Anlage
Plant
Anlage
Plant
Anlage
Plant
Anlage
Plant
Anlage
Plant
Anlage
Plant
Anlage
Plant
Anlage
Plant
Einbauort
Mounting place
Einbauort
Mounting place
Einbauort
Mounting place

&EAA
&EAB
&EBH
&EDB
&EFS
&ELU
&EMA
&EMB
&EMC
&EPB
=0
=00
=01
=100
=11
=Additions
=Customer
=MCC
+JB
+L
+SB

Date
Editor
Tested
Changes

Date

Name

Beschriftung
Labelling

04.03.2011
BEE/PLE
04.03.2011 KA

Strukturbeschreibung
Structure descprition

Vollstndige Bezeichnung
Complete name

Beschriftung
Labelling

Strukturbeschreibung
Structure descprition

Deckblatt
Cover sheet
Inhaltsverzeichnis
Table of contents
Revisionsbersicht
Revision overview
Strukturkennzeichen bersicht / Vorschriften
Structure indentification overview / instructions
Stromlaufplan
Circuit diagram
Aufbauplan
Arrangement drawing
Klemmenplan
Terminal connection diagram
Kabelbersicht
Cable layout
Klemmenanschlussplan
Terminal connecting plan
Stckliste
Parts list
Einspeisung
Incoming
SPS
PLC
Separator
Separator
Signalaustausch
Signal exchange
Zulaufpumpe
Feed pump
Zugabe
Addition
Kunde
Customer
Motorsteuerung
Motor starter
Abzweigdose
Junction box
Lokal
Local
Sensorblock
Sensor bloc

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Strukturkennzeichenbersicht
Structure indicator

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EDB

Bl./Sh.
7
67 Bl./Sh.

Vorschriften / Spezifikation
Instruction / specification
Schaltschrank :
Control cabinet :
Bezeichnung Schaltschrank
Name control cabinet

Ausfhrung:
Version:
CC

Aderkennzeichnung
Core indentification

YES

Lackierung Gehuse
Painting cabinet

Munsell 7.5 BG 7/2

Potentialbezeichnung
Potential designation

NO

Schutzart
Protective rating

IP54

Halogenfreie Verdrahtung / Kanle


Halogen free wiring / channels

YES

Umgebungstemperatur
Ambient temperature

~45 C

Kabelkennzeichnungsschilder
Cable marking plates

YES

Klassifizierung
Classification

...

Kennzeichnungsschilder
Marking plates

PLASTIC WHITE, LETTERS BLACK

Schnittstelle:
Interface:
Bus Verbindung zum Kunden PLC
Bus connection to customer PLC

NO

Einspeisung:
Incoming:
Netz-/ Anschlussspannung
Mains- / side voltage

230V AC

Netzfrequenz
Mains frequency

60 Hz

Drehfeld
Rotary field

CLOCKWISE ROTATION

Spannungstoleranz
Voltage tolerance

+/-5 %

Kabeleinfhrung
Cable inlet

BOTTOM

Einspeisung redundant
Incoming redundant

NO

Steuerspannungen:
Control voltages:

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Steuerspannung 1
Control voltage 1

230V AC

Steuerspannung 2
Control voltage 2

24V DC

Benennung/Description:

Informations-Blatt
Information-sheet

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EDB

Bl./Sh.
8
67 Bl./Sh.

Verdrahtung
Wiring
Stromkreise
Electrical circuits

Leiter
Conductor

Hauptstromkreise
Main circuits

230V AC

L1
L2
L3
N
PE

Farbe
Colour
Schwarz
Black
Schwarz
Black
Schwarz
Black
Hellblau
Light blue
Grn / Gelb
Green / yellow

Querschnitt
Cross-section

Stromkreise
Electrical circuits

Steuerspannung
Control voltage

1,5mm

Leiter
Conductor

Farbe
Colour
Rot
Red
Rot / Wei
Red / white

Querschnitt
Cross-section

Rot
Red
Blau
Blue

Wei
White
Braun
Brown

Messleitung
Measuring circuit

Wei
White

0,75mm

Stromwandlerleitungen
Current transformer lines

Schwarz
Black

2,5mm

Verriegelungsleitungen (AC/DC)
Interlocking conductors (AC/DC)

Orange

0,75mm

230V AC

L
N

"

1,5mm

2,5mm

24V DC

+
-

Analog abgeschirmt
Analog screened

L+
M

Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

0,75mm

"

"

Steuerspannung
Control voltage

Date
Editor
Tested

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Informations-Blatt
Information-sheet

"

0,75mm

"

Rev.01 =
As built +

Sprache:
Language:

0,75mm

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EDB

Bl./Sh.
9
67 Bl./Sh.

23

31

24

/21.1 32

13

230V AC

L1 / 11.0
N / 11.0

14

-S1

-F1
C 6A

Daten Einspeisung:
Data incoming:

-WD001
MPRXCX
2x2,5 mm

Date
Editor
Tested
Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

Filterlfter
Filter fan

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Umgebungstemperatur:
Ambient temperature:

~45 C

50 m

PE

PE

PE

-1M

-1T

-1G

U:

Benennung/Description:

Einspeisung
Incoming

230V AC
60 Hz

f:
P:

Erdung Gehuse 1
Earthing cabinet 1

PE

M
1~

Erdung Tr 1
Earthing door 1

Einspeisung
Incoming

max. Kabellnge:
Max. Cable length:

Erdung Montageplatte 1
Earthing mounting plate 1

Erdung Schirm
Earthing screen

=Customer
+L-X

Vorsicherung:
Pre-fuse:

L
N

L1

PE

19/18W
Schaltschranklfter
Cabinet fan

2,5 mm

-PE

-PE

-M1

Changes

-PE

-X1

-PE
4

-SC
3

-PE

GLAND

-X1

-PE

min. Querschnitt:
Min. Cross-section:

Icn:
Vollaststrom:
Full load current:

Rev.01 = 0
As built +

Sprache:
Language:

~2 A

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EFS

Bl./Sh.
10
67 Bl./Sh.

N/L2

230V AC

L1

10.9 / L1
10.9 / N

-T2

INPUT

GEA
power

-P1
x2

ON

OFF

x1

120/230VAC
24VDC/5A

A
B

M'

PE

L+'

L+

OUTPUT

M.A / 13.6
M.K / 22.0
M.R / 12.0
1

-24M

-PE

-PE

M.X / 18.0
24V DC
24V DC
24V DC

Steuerspannung DC
Control voltage DC

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Steuerspannung 24VDC
Control voltage 24VDC

L+.A / 13.6
L+.K / 23.0
L+.X / 12.0

Spannungsversorgung
Power supply

Rev.01 = 0
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EFS

Bl./Sh.
11
67 Bl./Sh.

24V DC

11.9 / L+.X

24V DC

L+.X / 16.0

=00-K1
/24.4

E2.7
8

X10

11.9 / M.R

M.R / 14.0

GLAND

-X2

-PE

Brcke entfernen bei


Anschlu eines
externen Not-Halt!
Remove link in case of
an external
emergency stop!

-WG008
MPRXCX
2x1,5 mm

=MCC
PE

/13.0
PE

Separator
Not-Halt
Separator
emergency stop
Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Not-Halt
Emergency stop

Rev.01 = 0
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EFS

Bl./Sh.
12
67 Bl./Sh.

Separatormotor
Separator motor

11.9 / L+.A
11.9 / M.A

24V DC

24V DC

L+.A / 14.0
M.A / 15.0

=MCC
/12.1
/14.1
/19.1

Strommessung Separator
Current measuring separator

...V/50/60Hz
L1

L2

L3

=00-K1

-X2

AI0-I

X13
2

11

-WG006
MPRXCX
2x1,5 mm

4-20mA = 0-50A
/25.5

-X2
1

A1

A2

14

2
GLAND
-PE

PE

12

-K1
/14.4

-Q1

0-.../.../1A

S2

50/1A

-X1

8
output
0/4-20mA

A1

T1

input
0-1A

GLAND
-PE

PE

7+

9-

-B1

-X1

S1

-T1
*0_9_011

-WG007
MPRXCX
2x2,5 mm

-B2

-F1
A2

T2

-PE

M
3~

*0_1_001
...kW/...A

T1

T2

Separator
Separator

Date
Editor
Tested
Changes

Date

Name

PE

W1

V1

Linkslauf
Anti-clockwise rotation
U1

GEA_Westfalia_Separator

04.03.2011
BEE/PLE
04.03.2011 KA

PTC-Fhler
Separator
PTC-feeler
separator

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Separator
Separator

Rev.01 = 01
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EFS

Bl./Sh.
13
67 Bl./Sh.

13.9 / L+.A

24V DC

24V DC

=00-K1

L+.A / 15.0

=00-K1

/24.5

/24.5

E0.0

E0.1
2

X11

X11

=00-K1
/25.4

A1.0

A1

X12

A2

-K1
12.9 / M.R

M.R / 19.0

-X2
WG009 / 16.2

GLAND

21

20

-PE

WG009. / 16.3

-WG009
MPRXCX
4x1,5 mm

=MCC

14
11 /13.5

/13.0
PE

12
PE

Separator
Betrieb
Separator
operation
Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Separator
Strung
Separator
failure

Kunde:
Customer:
Projekt:
Project:

Separator
Start/Stop
Separator
start/stop
GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Separator
Separator

Rev.01 = 01
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EFS

Bl./Sh.
14
67 Bl./Sh.

14.9 / L+.A
13.9 / M.A

24V DC

24V DC

L+.A / 22.0

=00-K1
0-12000 r.p.m.
/24.5

E0.3

4+

X11

24VDC

-X2

2-

1+

5+

6-

-T2

-WG004
MPRXCX
7x1,5 mm

+JB

-1X10

*0_9_020
SI

-WG101
.-O
2x0,34 mm

+ BN = brown
- BU = blue

Drehzahlberwachung
Speed monitoring device

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Separator Drehzahlmessung
Separator speed measuring

Rev.01 = 01
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EFS

Bl./Sh.
15
67 Bl./Sh.

=00-K1

=00-K1

4-20mA
/25.5

4-20mA
/25.5

AI1-I

AI2-I

X13

=00-K1

X13

/24.5

E0.5
6

X11

24V DC

12.9 / L+.X

24V DC

L+.X / 19.0

14.1 / WG009

-WG004
MPRXCX
7x1,5 mm

GLAND

10

-X2

-PE

14.2 / WG009.

L+_1X10 / 17.1
PE

GLAND

-1X10

+JB

PE

-WG121
MPRXCX
4x1,5 mm

+SB

*1_9_002

*0_9_014
P

PSL/H
4-20mA

Reinoel
Ablaufdruck
Clean-oil
discharge pressure
Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

A/Q

-WG203
.-O
3x0,75 mm
1

-WG202
.-O
2x0,34 mm
1

-WG201
.-O
2x0,34 mm

-1X20

PE_1X20 / 18.6
M_1X20 / 18.5

*0_9_013
P

SMS
4-20mA

WMS

Schlammraumberwachung
Sludge space monitoring

Kunde:
Customer:
Projekt:
Project:

Wasserabfuhr
Water monitoring system

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Separator Signale
Separator signals

Rev.01 = 01
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EFS

Bl./Sh.
16
67 Bl./Sh.

=00-K1
/24.5

E1.7

-X2

11

16

X11

-WG011
MPRXCX
7x1,5 mm

+JB

16.3 / L+_1X10

M_1X10 / 18.3
-1X10

11

Reserve
Spare

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

10

Reserve
Spare

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Separator Vibro
Separator vibro

Rev.01 = 01
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EFS

Bl./Sh.
17
67 Bl./Sh.

=00-K1

=00-K1

=00-K1

=00-K1

/25.4

/25.4

/25.4

/25.4

/25.4

A0.2

A0.1

A0.4

A0.5

X12
6

X12
5

X12

X12

X12

=00-K1

A0.0

11.9 / M.X

19

GLAND

17

GLAND

10

PE

18
18
11

17

16

14

15

-PE

GLAND

13

-X2

12

-PE

-WG011
MPRXCX
7x1,5 mm

17.1 / M_1X10

14

PE

-PE

-1X10

PE

16

-PE

-PE

GLAND

13

GLAND

-1X10

12

-PE

15

+JB

-WG122
MPRXCX
3x1,5 mm

+SB

16.3 / M_1X20

16.3

Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

Verdrngungs- und
Fllwasser
Displacem- and
filling water
GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

PE

Benennung/Description:

Separator Ventile
Separator valves

PE

*0_7_011
-

*0_7_010

PE

-WG205
.-J
3x0,75 mm

*9_7_005

Steuerwasser
Operating water

PE

-WG204
.-J
3x0,75 mm

Zulaufventil
Feed valve

PE

*9_7_004
-

*8_7_002

Date
Editor
Tested

-WG106
MPRXCX
2x1,5 mm
+

-WG105
MPRXCX
2x1,5 mm
+

-WG010
MPRXCX
2x1,5 mm

-1X20

PE_1X20

Kreislaufventil
Circulation valve

Wasserabfuhrventil
Water discharge valve

Rev.01 = 01
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EFS

Bl./Sh.
18
67 Bl./Sh.

24V DC

16.9 / L+.X

=00-K1
/24.5

E1.0
9

X11

14.9 / M.R

M.R / 21.0
GLAND

-X2

-PE
1

Brcke entfernen bei


Anschlu einer
Zulaufpumpe!
(Option)
Link remove at
connection of an feed
pump! (optional)

-WG005
MPRXCX
2x1,5 mm

=MCC
PE

/13.0
PE

Rckmeldung Zulaufpumpe
Feed back feed pump

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Freigabe Produkt Temperaturregelung


Release product temperature control

Rev.01 = 11
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EFS

Bl./Sh.
19
67 Bl./Sh.

min / max
Temperaturberwachung
Min / max
temperature monitoring

=00-K1
4-20mA = 0-120C
/25.5
/25.5

AIR-P

16

X13

15

X13

AIR-N

SC

-X2

=0-SC

-SC

-WG003
.CY-O
4x1,5 mm

*0_9_006

PT100
2

PT100

Reserve
Spare

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Produkt Temperaturregelung
Product temperature control

min / max
Temperaturberwachung
Min / max
temperature monitoring
Rev.01 = 11
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EFS

Bl./Sh.
20
67 Bl./Sh.

=00-K1

=00-K1

=00-K1

/25.4

/25.4

/25.4

/25.4

A1.3

A1.4

A1.5

14
A1

A1

A1

8
A1

A2

-K4
A2

-K3
A2

-K2
A2

-K1

X12

13

X12

12

X12

=00-K1

A0.7
X12

19.9 / M.R

Sammelstrung
Common failure

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GLAND

TAH Temperatur
Alarm max
TAH temperature
alarm max
GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

PE

-WG004
MPRXCX
2x1,5 mm
PE

-X

PE
7

GLAND

Wasserschlossalarm
Water seal broken alarm

14

12

11

11

-X

PE

-WG003
MPRXCX
2x1,5 mm
PE

-X

Kunde

3
-WG002
MPRXCX
2x1,5 mm

PE

=Customer
+L-X

/21.5

PE

GLAND

-X2

-K4

/21.3

-PE

-WG001
MPRXCX
2x1,5 mm

14

12

14

12

31
/10.1

-K3

/21.2

32

11

/21.1

12

12

-K2

=0-S1

11 /21.5

11 /21.3

12

14

12

12

-K1

14

14
11 /21.2

11

14
11 /21.0

GLAND

14

-X

TAL Temperatur
Alarm min
TAL temperature
alarm min
Benennung/Description:

Signalaustausch
Signal exchange

Rev.01 = 100
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EFS

Bl./Sh.
21
67 Bl./Sh.

=00-K1

=00-K1
/25.5

/25.5

/25.5

/25.5

AI1-C

AI2-C
-

AI3-C

X13

X13
12

X13

X13

=00-K1

AI0-C
-

8
Name

=00-K1

24V DC

M.K / 23.0

Date
Editor
Tested
Date

/24.5

Masse Analog
Ground analog

Changes

=00-K1

E0.7
X11

15.9 / L+.A
11.9 / M.K

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

Masse Analog
Ground analog

Masse Analog
Ground analog

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Masse Analog
Ground analog

Benennung/Description:

SPS bersicht
PLC overview

Rev.01 = 00
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EFS

Bl./Sh.
22
67 Bl./Sh.

-K1

-X12

...
...
...
...

+1.7
+2.7
+0.7
+1.7

8
7
6
5
4
3
2

10

11

12

13

14

15

16

AI1-C

AI2-U

AI2-I

AI2-C

AI3-U

AI3-I

AI3-C

M ana

M ana

AIR-P

AIR-N

16

15

14

13

12

11

10

+2.0
+2.1
+2.2
+2.3
+2.4
+2.5
+2.6
+2.7
2L+
2L+
2M
3L+
3L+
3M
1L+
1M

13
12
11
10
9
8
7
6
5
4
3
2
1

-X1
L+
M
AT1
AT2

4
3
2
1

1M /24.4
X10:16

1L+ /24.4
X10:15

3M /24.4
X10:14

3L+ /24.4
X10:12

X10:11

X10:9

2M /24.4

DO/DI 24VDC
Pover Supply
2L+ /24.4

6
M ana

AO1-I

4
AO1-U

M ana

2
AO0-I

AO0-U
L+

AT2

Digital Input 24VDC

X1:4

X1:3

X1:2

X1:1

AT1

Analog Output

-X10

14

-PE

Date
Editor
Tested
Name

PT100

11.9 / L+.K
22.9 / M.K

Date

10

-X14

A
B
SC

Changes

11

AI1-I

3
AI0-C

Analog Input

A
B
SC

12

AI1-U

2
AI0-I

X2/MPI

-X13

AI0-U

A
B
SC

13

15

PE

A
B
SC

DI +0.0
DI +0.0
DO +0.0
DO +1.0

14

16

X10:PE

1L+
=
1M
=
2L+,2M=
3L+,3M=

X5/P-BUS

15

Input 24VDC, 4A

MMC

-X7

+1.7
+1.6
+1.5
+1.4
+1.3
+1.2
+1.1
+1.0
+0.7
+0.6
+0.5
+0.4
+0.3
+0.2
+0.1
+0.0

16

Digital Output 24VDC 0,5A

+1.7
+1.6
+1.5
+1.4
+1.3
+1.2
+1.1
+1.0
+0.7
+0.6
+0.5
+0.4
+0.3
+0.2
+0.1
+0.0

-X11

Digital Input 24VDC

6ES7613-1SB02-0AC0

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

SPS Spannungsversorgung
PLC power supply

Rev.01 = 00
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EFS

Bl./Sh.
23
67 Bl./Sh.

-K1

X10:1
X10:2
X10:3
X10:4
X10:5
X10:6
X10:7
Separator Not-Halt
Separator emergency stop

24V

=0-T2:L+

/12.1

/23.5

X10:8

X10:9
X10:10

0V

/23.5

24V

/23.5

X10:11
X10:12
X10:13

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

0V

/23.5

24V

/23.5

0V

/23.5

X10:14
X10:15
X10:16

E2.0

E0.0

E2.1

E0.1

E2.2

E0.2

E2.3

E0.3

E2.4

E0.4

E2.5

E0.5

E2.6

E0.6

E2.7

E0.7

2L+

E1.0

2L+

E1.1

2M

E1.2

3L+

E1.3

3L+

E1.4

3M

E1.5

1L+

E1.6

1M

E1.7

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

SPS bersicht
PLC overview

X11:1
X11:2

/14.1

=01-X2:20

Separator Strung
Separator failure

/14.2

=01-X2:21

Separator Strung
Separator failure

/15.2

=01-T2:4+

Drehzahlberwachung
Speed monitoring device

/16.3

=01-X2:10

Wasserabfuhr
Water monitoring system

/22.1

=01-T2:5+

/19.1

=MCC

Separator Strung
Separator failure

/17.4

=01-X2:11

Reserve
Spare

X11:3
X11:4
X11:5
X11:6
X11:7
X11:8

X11:9
X11:10
X11:11
X11:12
X11:13
X11:14
X11:15
X11:16

Rev.01 = 00
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EFS

Bl./Sh.
24
67 Bl./Sh.

-K1

Zulaufventil
Feed valve

=01-X2:12

/18.1

Verdrngungs- und Fllwasser


Displacem- and filling water

=01-X2:15

/18.4

Steuerwasser
Operating water

=01-X2:14

/18.3

X12:1
X12:2
X12:3
X12:4

Kreislaufventil
Circulation valve

=01-X2:17

/18.5

Wasserabfuhrventil
Water discharge valve

=01-X2:18

/18.6

X12:5
X12:6
X12:7

Sammelstrung
Common failure

=100-K1:A1

/21.1

X12:8

A0.0

AI0-U

A0.1

AI0-I

A0.2

AI0-C

A0.3
A0.4

AI1-U

AI1-I

A0.5

AI1-C

A0.6
V

AI2-U

AI2-I

A0.7

AI2-C
-

Separator Start/Stop
Separator start/stop

=01-K1:A1

/14.4

X12:9
X12:10
X12:11

Wasserschlossalarm
Water seal broken alarm

=100-K2:A1

/21.2

TAH Temperatur Alarm max


TAH temperature alarm max

=100-K3:A1

/21.3

TAL Temperatur Alarm min


TAL temperature alarm min

=100-K4:A1

/21.5

X12:12
X12:13
X12:14
X12:15
X12:16

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

AI3-U

AI3-I

A1.0
A1.1

AI3-C

X13:1
X13:2
X13:3

/13.7

=01-T1:8

Strommessung Separator
Current measuring separator
Masse Analog
Ground analog

/22.2

X13:4
X13:5
X13:6

/16.1

=01-X2:6

/22.3

-K1:3

/16.2

=01-X2:8

Reinoel Ablaufdruck
Clean-oil discharge pressure
Masse Analog
Ground analog

X13:7
X13:8
X13:9

Schlammraumberwachung
Sludge space monitoring

/22.4

Masse Analog
Ground analog

/22.5

Masse Analog
Ground analog

X13:10
X13:11
X13:12

A1.2
A1.3

MANA

A1.4

Mana

X13:13
X13:14

A1.5
A1.6

AIR-P
PT100

A1.7

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

AIR-N

Benennung/Description:

SPS bersicht
PLC overview

X13:15
X13:16

/20.6

=11-X2:5

min / max Temperaturberwachung


Min / max temperature monitoring

/20.6

=11-X2:6

min / max Temperaturberwachung


Min / max temperature monitoring

Rev.01 = 00
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EFS

Bl./Sh.
25
67 Bl./Sh.

-K1

AO0-U
AO0-I
MANA

X14:1
X14:2
X14:3
X14:4

AO1-I
MANA

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

SPS bersicht
PLC overview

X14:5
X14:6

Rev.01 = 00
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EFS

Bl./Sh.
26
67 Bl./Sh.

410 mm
380 mm

54 mm

Terminals

=00-K1

PE
Cable
route

Terminals
PE
=0-S1

=0-P1

=0-M1

pocket for circuit diagram

10 mm

NO. _ LO-ME PURIFIER


CONTROL PANEL

600 mm
582 mm

360 mm
350 mm

Cabinet

Custody
space
for key

330

150

M10

=00-K1
=0-M1
=0-P1
=0-S1

27

Steuergert Timing unit


Filter / Lfter Filter / fan
Spannungsversorgung Power supply
Hauptschalter Isolator

36
54

15

10,2

Mastab 1:4,5 mm
Scale 1:4,5 mm

LO-ME 1/2

Gewicht: ca. 30kg


Weight: ca. 30kg
Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Aufbauplan
Arrangement drawing

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& ELU

Bl./Sh.
27
67 Bl./Sh.

Mountingplate

37x75

=01-T2

=01-T1

=01-K1
=100-K1
=100-K2
=100-K3
=100-K4

=0-F1

=0-T2

=0-24M

37x75

=11-X2

=100-X2

37x75

PE
37x75

=01-X2

=01-X1

=0-X2

=0-X1

37x75

37x75

PE

Date
Editor
Tested
Changes

Date

Name

Cable glands

Yard cable size

8x M20
6x M20
3x M20

10,0 - 12,5mm
12,0 - 14,5mm
Spare

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

0005-4515-600
0005-4516-600
0005-4443-630

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Aufbauplan
Arrangement drawing

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& ELU

Bl./Sh.
28
67 Bl./Sh.

Regelung Gert D10


Control unit D10
Taste
Button
GEA Westfalia Separator

Prozess Stop
Process stop
Prozess Start
Process start
Lampentest
Lamp test
Serienbetrieb
Series operation
Hilfe
Help
Separator
Separator
Zulauf
Feed
Schlamm
Sludge

1
2
3

4
S

F2

F3

F4

165

F1

6
7

SF
DC5V

ESC

FRCE
RUN

STOP

EDIT

202x155mm

Tiefe:
depth:

88mm

Gewicht:
weight:

1,35kg

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

PID

Zurck
Return

Process
STOP
Process
START

LAMPTEST
SERIES
1

Benennung/Description:

D10
D10

FEED

SLUDGE

PID

HOME
DIR

Bestell-nr.
order no.

0005-4050-430

Programm-Nr.
program-no.

8106-0D10-101

Rev.01 =
As built +

Sprache:
Language:

HELP

ENTER

215

Ausschnittmass:
cutout dimension:

Symbol
Symbol

Benennung
Designation

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& ELU

Bl./Sh.
29
67 Bl./Sh.

Not-Halt Gehuse mit Schutzkragen


Emergency stop cabinet with protective collar
=Additions
-S01

71 mm

54 mm

85 mm

Not-Halt-Box

m
5

109 mm

85 mm

61 mm

protection class: "IP 65"

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

Note: Installation should be carry out by customer!

18 mm

M20
8-13mm

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Not-Halt-Box
Energency stop box

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& ELU

Bl./Sh.
30
67 Bl./Sh.

Stromwandler
Current transformer
(TAID)
42

=Additions
-B1

84

50/1A
Stromwandler
Current transformer

60

57

56

4mm

5,5
50

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Stromwandler
Current transformer

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& ELU

Bl./Sh.
31
67 Bl./Sh.

Motorvollschutzrelais
Motor protection relay
(3RN10 10)

=Additions
-F1

91

Motorvollschutzrelais
Motor protection relay

22,5
5
A1

T1

86

A1 / A2 =

T2

T1 / T2 =
95 / 96 =

80

74
95

96

97

98

A2
10

10

90

62

97 / 98 =

Spannungsversorgung
power supply
PTC
PTC
Schliesser
NO-contact
Oeffner
NC-contact

28
57

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Motorvollschutzrelais
Motor protection relay

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& ELU

Bl./Sh.
32
67 Bl./Sh.

SC
SC
SC
SC
SC
SC
SC
SC

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

Kabeltyp
Cable type

Kabeltyp
Cable type

GLAND

-PE

&EFS/10.1

-WG008

SC

GLAND

-PE

&EFS/12.2

=01-WG006

SC

GLAND

-PE

&EFS/13.4

=01-WG007

SC

GLAND

-PE

&EFS/13.4

=01-WG009

SC

GLAND

-PE

&EFS/14.3

GLAND

GLAND

-PE

&EFS/16.3

SC

GLAND

-PE

&EFS/18.2

GLAND

GLAND

-PE

&EFS/18.7

=11-WG005

SC

GLAND

-PE

&EFS/19.2

=100-WG001

SC

GLAND

-PE

&EFS/21.1

=01+JB-1X10_GLAND
=01-WG010
=01+JB-1X10_GLAND

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =0+-GLAND
Terminal connection diagram =0+-GLAND

Zielbezeichnung
Target designation

Kabelname
Cable name

SC

Brcke
Link

-WD001

Zielbezeichnung
Target designation

Anschluss
Connection

=0+-GLAND

Klemme
Terminal

SC

Klemmenleistenbezeichnung
Terminal strip designation

Kabelname
Cable name

MPRXCX 2x2,5 mm

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

MPRXCX 2x2,5 mm

MPRXCX 4x1,5 mm

MPRXCX 7x1,5 mm

MPRXCX 2x1,5 mm

SC

Date
Editor
Tested
Name

Anschluss
Connection

Einspeisung
Incoming
Separator Not-Halt
Separator emergency stop
Separator Aus
Separator off
Entleerungsberwachung
Ejection monitoring
Separator Strung
Separator failure
Wasserabfuhr
Water monitoring system
Zulaufventil
Feed valve
Wasserabfuhrventil
Water discharge valve
Rckmeldung Zulaufpumpe
Feed back feed pump
Sammelstrung
Common failure

Date

=100
WG001
=11
WG005
=01
WG011
=01
WG010
=01
WG004
=01
WG009
=01
WG007
=01
WG006
=0
WG008
=0
WD001

Funktionstext
Function text

Changes

MPRXCX 7x1,5 mm

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

Rev.01 = 0
As built +

Sprache:
Language:

Seite / Spalte
Page / Column

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMA

Bl./Sh.
33
67 Bl./Sh.

SC
SC

Date
Editor
Tested
Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

Kabeltyp
Cable type

Kabeltyp
Cable type

GLAND

-PE

&EFS/21.2

=100-WG003

SC

GLAND

-PE

&EFS/21.4

=100-WG004

SC

GLAND

-PE

&EFS/21.5

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =0+-GLAND
Terminal connection diagram =0+-GLAND

Zielbezeichnung
Target designation

Kabelname
Cable name

SC

Brcke
Link

=100-WG002

Zielbezeichnung
Target designation

Anschluss
Connection

=0+-GLAND

Klemme
Terminal

SC

Anschluss
Connection

Wasserschlossalarm
Water seal broken alarm
TAH Temperatur Alarm max
TAH temperature alarm max
TAL Temperatur Alarm min
TAL temperature alarm min

Klemmenleistenbezeichnung
Terminal strip designation

Kabelname
Cable name

=100
WG004
=100
WG003
=100
WG002

Funktionstext
Function text

Changes

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

Rev.01 = 0
As built +

Sprache:
Language:

Seite / Spalte
Page / Column

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMA

Bl./Sh.
34
67 Bl./Sh.

Kabeltyp
Cable type

Kabeltyp
Cable type

Klemmenleistenbezeichnung
Terminal strip designation

-T2

&EFS/11.6

-PE

PE

=01-K1

A2

&EFS/11.6

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =0+-24M
Terminal connection diagram =0+-24M

Zielbezeichnung
Target designation

Kabelname
Cable name

13

Zielbezeichnung
Target designation

Anschluss
Connection

=01-X2

Funktionstext
Function text

Brcke
Link

Klemme
Terminal

Steuerspannung DC
Control voltage DC

Kabelname
Cable name

Anschluss
Connection

=0+-24M

Rev.01 = 0
As built +

Sprache:
Language:

Seite / Spalte
Page / Column

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMA

Bl./Sh.
35
67 Bl./Sh.

Kabeltyp
Cable type

Kabeltyp
Cable type

Klemmenleistenbezeichnung
Terminal strip designation

-PE

&EFS/10.3

-M1

PE

PE

-PE

&EFS/10.5

-1M

PE

PE

-PE

&EFS/10.6

-1T

PE

PE

-PE

&EFS/10.6

-1G

PE

PE

-PE

&EFS/10.6

-PE

PE

-T2

PE

&EFS/11.6

-PE

PE

-24M

&EFS/11.6

Steuergert
Timing unit

-PE

PE

=00-K1

X10:PE

&EFS/23.6

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =0+-PE
Terminal connection diagram =0+-PE

Zielbezeichnung
Target designation

Kabelname
Cable name

PE

Erdung Schirm
Earthing screen
Filterlfter
Filter fan
Erdung Montageplatte 1
Earthing mounting plate 1
Erdung Tr 1
Earthing door 1
Erdung Gehuse 1
Earthing cabinet 1
Steuerspannung DC
Control voltage DC

Zielbezeichnung
Target designation

Anschluss
Connection

SC

Funktionstext
Function text

Brcke
Link

Klemme
Terminal

-SC

Kabelname
Cable name

Anschluss
Connection

=0+-PE

Rev.01 = 0
As built +

Sprache:
Language:

Seite / Spalte
Page / Column

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMA

Bl./Sh.
36
67 Bl./Sh.

Changes

Date

Name

SC

-SC

&EFS/10.3

=11-X2

SC

SC

-SC

&EFS/20.7

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =0+-SC
Terminal connection diagram =0+-SC

Kabelname
Cable name

PE

Zielbezeichnung
Target designation

Anschluss
Connection

Klemme
Terminal

-PE

Zielbezeichnung
Target designation

Brcke
Link

Anschluss
Connection

Erdung Schirm
Earthing screen
min / max Temperaturberwachung
Min / max temperature monitoring

Date
Editor
Tested

=0+-SC

Kabelname
Cable name

Funktionstext
Function text

Kabeltyp
Cable type

Kabeltyp
Cable type

Klemmenleistenbezeichnung
Terminal strip designation

Rev.01 = 0
As built +

Sprache:
Language:

Seite / Spalte
Page / Column

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMA

Bl./Sh.
37
67 Bl./Sh.

Kabeltyp
Cable type

=Customer+L-X

L1

-F1

&EFS/10.1

=Customer+L-X

-F1

&EFS/10.1

-S1

13

&EFS/10.4

Reserve
Spare
Filterlfter
Filter fan
=

-M1

-M1

Seite / Spalte
Page / Column

&EFS/10.4
-S1

23

&EFS/10.5

Date
Editor
Tested
Changes

Zielbezeichnung
Target designation

Kabelname
Cable name

Zielbezeichnung
Target designation

Anschluss
Connection

Einspeisung
Incoming

Funktionstext
Function text

Brcke
Link

Klemme
Terminal

=0+-X1

Anschluss
Connection

Kabeltyp
Cable type

Klemmenleistenbezeichnung
Terminal strip designation

Kabelname
Cable name

MPRXCX 2x2,5 mm

=0
WD001

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =0+-X1
Terminal connection diagram =0+-X1

&EFS/10.5

Rev.01 = 0
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMA

Bl./Sh.
38
67 Bl./Sh.

Separator Not-Halt
Separator emergency stop

Separator Not-Halt
Separator emergency stop

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

=MCC-X

=MCC-X

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =0+-X2
Terminal connection diagram =0+-X2

Zielbezeichnung
Target designation
-T2

Anschluss
Connection

Brcke
Link

Klemme
Terminal

Zielbezeichnung
Target designation

Anschluss
Connection

=0+-X2

Kabelname
Cable name

Kabeltyp
Cable type

Klemmenleistenbezeichnung
Terminal strip designation
Kabeltyp
Cable type

Funktionstext
Function text

Kabelname
Cable name

MPRXCX 2x1,5 mm

=0
WG008

Seite / Spalte
Page / Column

L+

=01-X2

=00-K1

X10:8

&EFS/12.1

&EFS/12.1

Rev.01 = 0
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMA

Bl./Sh.
39
67 Bl./Sh.

Zielbezeichnung
Target designation

Anschluss
Connection

Brcke
Link

Klemme
Terminal

Zielbezeichnung
Target designation

Anschluss
Connection

=01+-X1

Kabelname
Cable name

Kabeltyp
Cable type

Klemmenleistenbezeichnung
Terminal strip designation
Kabeltyp
Cable type

Funktionstext
Function text

Kabelname
Cable name

MPRXCX 2x2,5 mm

=01
WG007

Seite / Spalte
Page / Column

Entleerungsberwachung
Ejection monitoring

=MCC-X_

-T1

&EFS/13.4

=MCC-X_

-T1

&EFS/13.4

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =01+-X1
Terminal connection diagram =01+-X1

Rev.01 = 01
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMA

Bl./Sh.
40
67 Bl./Sh.

Kabeltyp
Cable type

Zielbezeichnung
Target designation

Anschluss
Connection

Brcke
Link

Klemme
Terminal

Zielbezeichnung
Target designation

Kabelname
Cable name

Kabeltyp
Cable type

=01+-X2

Anschluss
Connection

Funktionstext
Function text

Klemmenleistenbezeichnung
Terminal strip designation

Kabelname
Cable name

=01
WG010
=01
WG011
=01
WG009
=01
WG004
=01
WG006

MPRXCX 2x1,5 mm

MPRXCX 7x1,5 mm

MPRXCX 4x1,5 mm

MPRXCX 7x1,5 mm

MPRXCX 2x1,5 mm

Seite / Spalte
Page / Column

Separator Aus
Separator off

=MCC-X_

-K1

11

&EFS/13.4

=MCC-X_

-K1

12

&EFS/13.4

Drehzahlberwachung
Speed monitoring device

+JB-1X10

-T2

1+

&EFS/15.2

+JB-1X10

-T2

2-

&EFS/15.2

Reinoel Ablaufdruck
Clean-oil discharge pressure

+JB-1X10

=0-X2

&EFS/16.1

+JB-1X10

=00-K1

X13:5

&EFS/16.1

Separator Betrieb
Separator operation
Schlammraumberwachung
Sludge space monitoring
Separator Strung
Separator failure
Wasserabfuhr
Water monitoring system
Reserve
Spare
Zulaufventil
Feed valve

1
5
2

=00-K1

X13:8

&EFS/16.2

=11-X2

&EFS/16.3

10

=00-K1

X11:6

&EFS/16.3

+JB-1X10

10

11

=00-K1

X11:16

&EFS/17.4

-*8_7_002

12

=00-K1

X12:1

&EFS/18.1

-*8_7_002

13

=0-24M

&EFS/18.1

+JB-1X10

12

14

=00-K1

X12:3

&EFS/18.3

+JB-1X10

15

15

=00-K1

X12:2

&EFS/18.4

16

Kreislaufventil
Circulation valve
Wasserabfuhrventil
Water discharge valve
=
Betrieb
operation
Strung
failure

Date
Editor
Tested
Changes

Separator
Separator
Separator
Separator

&EFS/16.2

+JB-1X10

Steuerwasser
Operating water
Verdrngungs- und Fllwasser
Displacem- and filling water

+JB-1X10
=MCC

=MCC

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

&EFS/18.4

+JB-1X10

16

17

=00-K1

X12:5

&EFS/18.5

+JB-1X10

18

18

=00-K1

X12:6

&EFS/18.6

+JB-1X10

17

19

&EFS/18.7

=MCC

20

=00-K1

X11:1

&EFS/14.1

=MCC

21

=00-K1

X11:2

&EFS/14.2

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =01+-X2
Terminal connection diagram =01+-X2

Rev.01 = 01
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMA

Bl./Sh.
41
67 Bl./Sh.

Steuerwasser
Operating water
Wasserabfuhr
Water monitoring system
Drehzahlberwachung
Speed monitoring device

PE

Kabeltyp
Cable type

Zielbezeichnung
Target designation

Anschluss
Connection

Brcke
Link

Klemme
Terminal

Zielbezeichnung
Target designation

Kabelname
Cable name

Kabeltyp
Cable type

=01+JB-1X10

MPRXCX 7x1,5 mm

MPRXCX 7x1,5 mm

=01
WG004
=01
WG011

Anschluss
Connection

Funktionstext
Function text

Klemmenleistenbezeichnung
Terminal strip designation

Kabelname
Cable name

=01
WG122
=01
WG106
=01
WG105
=01
WG121
=01
WG101

.-O 2x0,34 mm

MPRXCX 4x1,5 mm

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

MPRXCX 3x1,5 mm

Seite / Spalte
Page / Column

-PE

&EFS/18.3

PE

&EFS/16.4

BN

-*0_9_020

-X2

&EFS/15.2

BU

-*0_9_020

-X2

&EFS/15.2

Reinoel Ablaufdruck
Clean-oil discharge pressure

+SB-1X20

-X2

&EFS/16.1

+SB-1X20

-X2

&EFS/16.1

=
Schlammraumberwachung
Sludge space monitoring
Wasserabfuhr
Water monitoring system
Reserve
Spare

&EFS/16.1

+SB-1X20

-X2

&EFS/16.2

+SB-1X20

-X2

10

&EFS/16.3

&EFS/17.1

&EFS/17.3

10

11

-X2

11

&EFS/17.4
&EFS/17.1

Steuerwasser
Operating water

-*9_7_004

12

-*9_7_004

13

&EFS/18.3
&EFS/18.4

-X2

14

&EFS/18.3

Verdrngungs- und Fllwasser


Displacem- and filling water

-*9_7_005

14

-*9_7_005

15

-X2

15

&EFS/18.4

+SB-1X20

16

-X2

17

&EFS/18.5

+SB-1X20

10

17

-X2

19

&EFS/18.7

+SB-1X20

11

18

-X2

18

&EFS/18.6

PE

-PE

Kreislaufventil
Circulation valve
Wasserabfuhrventil
Water discharge valve
=
Verdrngungs- und Fllwasser
Displacem- and filling water

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =01+JB-1X10
Terminal connection diagram =01+JB-1X10

&EFS/18.4

Rev.01 = 01
As built + JB

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMA

Bl./Sh.
42
67 Bl./Sh.

SC
SC
SC

Date
Editor
Tested
Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

Kabeltyp
Cable type

Kabeltyp
Cable type

=0-GLAND

GLAND

+SB-1X20

PE:PE

GLAND

=0-GLAND

GLAND

-WG105

SC

GLAND

-PE

&EFS/18.3

-WG106

SC

GLAND

-PE

&EFS/18.4

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =01+JB-1X10_GLAND
Terminal connection diagram =01+JB-1X10_GLAND

=01
WG004
=01
WG011

GLAND

Zielbezeichnung
Target designation

Kabelname
Cable name

PE:PE

Brcke
Link

+SB-1X20

Zielbezeichnung
Target designation

Anschluss
Connection

=01+JB-1X10_GLAND

MPRXCX 7x1,5 mm

MPRXCX 7x1,5 mm

Klemme
Terminal

SC

Anschluss
Connection

Wasserabfuhr
Water monitoring system
Wasserabfuhrventil
Water discharge valve
Steuerwasser
Operating water
Verdrngungs- und Fllwasser
Displacem- and filling water

Klemmenleistenbezeichnung
Terminal strip designation

Kabelname
Cable name

=01
WG106
=01
WG105
=01
WG122
=01
WG121

Funktionstext
Function text

Changes

MPRXCX 4x1,5 mm

MPRXCX 3x1,5 mm

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

SC

&EFS/16.3
SC

&EFS/18.7

Rev.01 = 01
As built + JB

Sprache:
Language:

Seite / Spalte
Page / Column

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMA

Bl./Sh.
43
67 Bl./Sh.

Kabeltyp
Cable type

Klemmenleistenbezeichnung
Terminal strip designation

+JB-1X10

&EFS/16.1

BK

-*1_9_002

+JB-1X10

&EFS/16.1

=01
WG121
=01
WG122

Kabelname
Cable name

Zielbezeichnung
Target designation

Anschluss
Connection

-*1_9_002

Zielbezeichnung
Target designation

Brcke
Link

Klemme
Terminal

WH

Funktionstext
Function text

Kabelname
Cable name

Reinoel Ablaufdruck
Clean-oil discharge pressure

=01
WG205
=01
WG204
=01
WG203
=01
WG202
=01
WG201

Anschluss
Connection

=01+SB-1X20

MPRXCX 3x1,5 mm

MPRXCX 4x1,5 mm

Kabeltyp
Cable type

.-O 2x0,34 mm

.-O 2x0,34 mm

.-O 3x0,75 mm

.-J 3x0,75 mm

.-J 3x0,75 mm

Seite / Spalte
Page / Column

Schlammraumberwachung
Sludge space monitoring

WH

-*0_9_014

BK

-*0_9_014

+JB-1X10

&EFS/16.2

+JB-1X10

&EFS/16.3

&EFS/16.2

Wasserabfuhr
Water monitoring system

BK

-*0_9_013

A/Q

BN

-*0_9_013

&EFS/16.3

GY

-*0_9_013

&EFS/16.3

Kreislaufventil
Circulation valve

BN

-*0_7_010

BU

-*0_7_010

+JB-1X10

16

&EFS/18.5
&EFS/18.5

Wasserabfuhrventil
Water discharge valve

BN

-*0_7_011

10

+JB-1X10

17

&EFS/18.7

BU

-*0_7_011

11

+JB-1X10

18

&EFS/18.6

-*0_7_010

PE

PE

+JB-1X10_GLAND

GLAND

-*0_7_011

PE

PE

+JB-1X10_GLAND

GLAND

Kreislaufventil
Circulation valve
Wasserabfuhrventil
Water discharge valve

PE
PE

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =01+SB-1X20
Terminal connection diagram =01+SB-1X20

SC
SC

&EFS/18.7

Rev.01 = 01
As built + SB

Sprache:
Language:

&EFS/18.6

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMA

Bl./Sh.
44
67 Bl./Sh.

Kabeltyp
Cable type

Zielbezeichnung
Target designation

Anschluss
Connection

Brcke
Link

Klemme
Terminal

Zielbezeichnung
Target designation

Kabelname
Cable name

Kabeltyp
Cable type

=100+-X2

Anschluss
Connection

Funktionstext
Function text

Klemmenleistenbezeichnung
Terminal strip designation

Kabelname
Cable name

=100
WG004
=100
WG003
=100
WG002
=100
WG001

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

MPRXCX 2x1,5 mm

Seite / Spalte
Page / Column

Sammelstrung
Common failure

=Customer+L-X

-K1

11

&EFS/21.1

=Customer+L-X

-K1

14

&EFS/21.1

Wasserschlossalarm
Water seal broken alarm

=Customer+L-X

-K2

11

&EFS/21.2

=Customer+L-X

-K2

14

&EFS/21.2

TAH Temperatur Alarm max


TAH temperature alarm max

=Customer+L-X

-K3

11

&EFS/21.3

=Customer+L-X

-K3

14

&EFS/21.4

TAL Temperatur Alarm min


TAL temperature alarm min

=Customer+L-X

-K4

11

&EFS/21.5

=Customer+L-X

-K4

14

&EFS/21.5

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =100+-X2
Terminal connection diagram =100+-X2

Rev.01 = 100
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMA

Bl./Sh.
45
67 Bl./Sh.

Kabeltyp
Cable type

Zielbezeichnung
Target designation

Anschluss
Connection

Brcke
Link

Klemme
Terminal

Zielbezeichnung
Target designation

Kabelname
Cable name

Kabeltyp
Cable type

=11+-X2

Anschluss
Connection

=11
WG003
=11
WG005

Funktionstext
Function text

Klemmenleistenbezeichnung
Terminal strip designation

Kabelname
Cable name

MPRXCX 2x1,5 mm

.CY-O 4x1,5 mm

Seite / Spalte
Page / Column

Rckmeldung Zulaufpumpe
Feed back feed pump

=MCC

=01-X2

&EFS/19.1

=MCC

=00-K1

X11:9

&EFS/19.1

Reserve
Spare

-*0_9_006

&EFS/20.5

-*0_9_006

&EFS/20.5

-*0_9_006

=00-K1

X13:15

&EFS/20.6

-*0_9_006

=00-K1

X13:16

&EFS/20.6

SC

SC

=0-SC

SC

&EFS/20.7

min / max Temperaturberwachung


Min / max temperature monitoring
min / max Temperaturberwachung
Min / max temperature monitoring
=

SC

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

-WG003

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenplan =11+-X2
Terminal connection diagram =11+-X2

Rev.01 = 11
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMA

Bl./Sh.
46
67 Bl./Sh.

Kabelbersicht
Cable layout
Kabelname
Cable name

/Seite.Pfad
/page.path

Ziel (bis)
Target (up to)

Kabeltyp
Cable type

Adern gesamt
Wires total

Adern
verwendet
Wires used

Querschnitt
Cross-section

Lnge
Length

Verschraubung / Klemmbereich
Cable gland / clamping range

=0-WD001

&EFS/10.1

=0-GLAND;=0-X1

=Customer+L-X

MPRXCX

2x

2,5 mm

M20x1,5 / 12-14,5mm

=0-WG008

&EFS/12.1

=0-GLAND;=0-X2

=MCC-X

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

=01-WG004

&EFS/15.1

=0-GLAND;=01-X2

=01+JB-1X10_GLAND;
=01+JB-1X10

MPRXCX

7x

1,5 mm

M20x1,5 / 12-14,5mm

=01-WG006

&EFS/13.4

=0-GLAND;=01-X2

=MCC-X_

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

=01-WG007

&EFS/13.4

=0-GLAND;=01-X1

=MCC-X_

MPRXCX

2x

2,5 mm

M20x1,5 / 12-14,5mm

=01-WG009

&EFS/14.1

=0-GLAND;=01-X2

=MCC

MPRXCX

4x

1,5 mm

M20x1,5 / 12-14,5mm

=01-WG010

&EFS/18.1

=0-GLAND;=01-X2

=01-*8_7_002

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

=01-WG011

&EFS/18.3

=0-GLAND;=01-X2

=01+JB-1X10_GLAND;
=01+JB-1X10

MPRXCX

7x

1,5 mm

M20x1,5 / 12-14,5mm

=01-WG101

&EFS/15.1

=01+JB-1X10

=01-*0_9_020

.-O

2x

0,34 mm

M12x1,5 / 3-6mm

=01-WG105

&EFS/18.3

=01+JB-1X10;
=01+JB-1X10_GLAND

=01-*9_7_004

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

=01-WG106

&EFS/18.4

=01+JB-1X10;
=01+JB-1X10_GLAND

=01-*9_7_005

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

=01-WG121

&EFS/16.1

=01+JB-1X10;
=01+JB-1X10_GLAND

=01+SB-1X20

MPRXCX

4x

1,5 mm

M20 Z14 / 12-14,5mm

=01-WG122

&EFS/18.5

=01+JB-1X10;
=01+JB-1X10_GLAND

=01+SB-1X20

MPRXCX

3x

1,5 mm

M20 Z14 / 12-14,5mm

=01-WG201

&EFS/16.1

=01+SB-1X20

=01-*1_9_002

.-O

2x

0,34 mm

Integrated in the sensor


block

=01-WG202

&EFS/16.2

=01+SB-1X20

=01-*0_9_014

.-O

2x

0,34 mm

Integrated in the sensor


block

=01-WG203

&EFS/16.3

=01+SB-1X20

=01-*0_9_013

.-O

3x

0,75 mm

Integrated in the sensor


block

=01-WG204

&EFS/18.5

=01+SB-1X20

=01-*0_7_010

.-J

3x

0,75 mm

Integrated in the sensor


block

=01-WG205

&EFS/18.6

=01+SB-1X20

=01-*0_7_011

.-J

3x

0,75 mm

Integrated in the sensor


block

=100-WG001

&EFS/21.1

=0-GLAND;=100-X2

=Customer+L-X

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

Date
Editor
Tested
Changes

Quelle (von)
Source (from)

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Kabelbersicht
Cable layout

Rev.01 =
As built +

Sprache:
Language:

Bemerkung
Remark

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMB

Bl./Sh.
47
67 Bl./Sh.

Kabelbersicht
Cable layout
Kabelname
Cable name

/Seite.Pfad
/page.path

Ziel (bis)
Target (up to)

Kabeltyp
Cable type

Adern gesamt
Wires total

Adern
verwendet
Wires used

Querschnitt
Cross-section

Lnge
Length

Verschraubung / Klemmbereich
Cable gland / clamping range

=100-WG002

&EFS/21.2

=0-GLAND;=100-X2

=Customer+L-X

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

=100-WG003

&EFS/21.3

=0-GLAND;=100-X2

=Customer+L-X

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

=100-WG004

&EFS/21.5

=0-GLAND;=100-X2

=Customer+L-X

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

=11-WG003

&EFS/20.5

=11-X2

=11-*0_9_006

.CY-O

4x

1,5 mm

M20x1,5 / 12-14,5mm

=11-WG005

&EFS/19.1

=0-GLAND;=11-X2

=MCC

MPRXCX

2x

1,5 mm

M20x1,5 / 10-12,5mm

Date
Editor
Tested
Changes

Quelle (von)
Source (from)

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Kabelbersicht
Cable layout

Rev.01 =
As built +

Sprache:
Language:

Bemerkung
Remark

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMB

Bl./Sh.
48
67 Bl./Sh.

Klemmenkasten Separator -1X10


Terminal box separator -1X10

Sensorblock -1X20
Sensor bloc -1X20

Verschraubung
Cable gland

Schaltschrank
Control cabinet

+JB-1X10
PE

-X2

PE

+
S
+
-

blue

blue

11

brown

PE

PE

PE

PE

brown

10

PE

Verdraengungs-u. fuellwasser
displacem. a. filling water

P
I

2x0,34mm
-WG202

3x0,75mm
-WG203

PSL/H Reinoel
Ablaufdruck
PSL/H clean oil
discharge pressure
SMS Schlammraumueberwachung
SMS sludge space monitoring

Wasserabfuhr
water monitoring system

grey

2x1,5mm
-WG106

brown

PE

Steuerwasser
operating water

black

2x0,34mm
-WG201

black
white

2x1,5mm
-WG105

black

blue

white

+
blue

brown

PE

19

18

18

-WG122
3x1,5mm
M20 (10-12,5mm)

17

17

16

-WG121
4x1,5mm
M20 (12-14,5mm)

15

16

14

15

+SB-1X20
1

brown

13

14

-WG011
7x1,5mm
M20 (12-14,5mm)

12

13

11

12
2

Drehzahlueberwachung
speed monitoring device

10

11

10

8
+

2x0,34mm
-WG101

blue

-WG004
7x1,5mm
M20 (12-14,5mm)

brown

2
1

PE

3x0,75mm
-WG204

3x0,75mm
-WG205

Kreislaufventil
circulation valve

Wasserabfuhrventil
water discharge valve

2
3

PE

Verschraubung
Cable gland

PE

Bestell-Nr.:0005-1827-280
order-no.:0005-1827-280

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenkasten bersicht
Terminal box overview

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMB

Bl./Sh.
49
67 Bl./Sh.

Hinweise zur Installation von Kabeln und Leitungen


Directions for installation from cables and conductors
*

Schutzmanahmen nach Bestimmungen des VDE bzw. zustndigen EVU ausfhren!


All protective measures are to be taken in accordance with electric codes, rules and regulations!

Generell sind die Vorgaben des lokalen Energieversorgers zwingend einzuhalten


In general the the rules and regulations of the lokal power authorities has to be followed.

Kabel und Leitungen sind so auszuwhlen und zu verlegen, dass eine Gefhrdung von Personen und der Umgebung ausgeschlossen ist.
Die angegebenen Kabelquerschnitte sind bezogen auf eine Kabellnge von 50m, Kupfer als Leitematerial, Verlegeart "C" und
eine maximale Umgebungstemperatur von 30C. Siehe hierzu DIN VDE 0298-4 (Verwendung von Kabeln und isolierten Leitungen fr Starkstromanlagen - Teil 4:
Empfohlene Werte fr die Strombelastbarkeit von Kabeln und Leitungen fr feste Verlegung in und an Gebuden und von flexiblen Leitungen).
Neben der Strombelastung sind bei der Errichtung von Kabel- und Leitungsanlagen weitere Faktoren zu bercksichtigen.
Siehe hierzu IEC 60364-5-52 (Errichten von Niederspannungsanlagen - Teil 5: Auswahl und Errichtung elektrischer Betriebsmittel - Kapitel 52: Kabel- und Leitungsanlagen)
Cables and lines must be selected and laid in a way to eliminate any risk to persons and the environment.
The cable cross-sections specified in these drawings are based on a max. length of 50m, copper as conducting material,laying version "C" and a maximum ambient temperature of 30C.
Refer also to DIN VDE 0298-4 (Usage of cables and cords in power installations - Part 4:
Recommended current-carrying capacity for sheathed and nonsheathed cables for fixed wirings in and around buildings and for flexible cables and cords).
Besides the current load are in the erection of wiring systems additional parameters to take into account.
Refer also to IEC 60364-5-52 (Erection of low voltage installations - Part 5: Selection and erection of electrical equipment - Chapter 52: Wiring systems)

Messleitungen sind grundstzlich abgeschirmt zu verlegen!


Measuring lines must always be laid shielded!

WD-Kabel getrennt vom WF-/WG-Kabeln verlegen!


WD-cables to be installed separate from WF-/WG-cable!

Alle Kabel mssen den Flammentest Anforderungen fr gebndelte Kabel nach IEC 60332-3 / IEEE 45-18.13 gerecht werden.
All cables must meet the flame test requirements for bunched cables acc. to IEC 60332-3 / IEEE 45-18.13.

Das gesamte Kabelmaterial muss halogenfrei nach IEC 60754-1, giftfrei nach IEC 60754 und korrosionsfrei nach IEC 60754-2 sein
All cable materials must be free of halogens acc. to IEC 60754-1, no toxicity acc. to 60754 and no corrosivity acc. to IEC 60754-2.

Alle Kabel mssen eine Abnahme der relevante Abnahmegesellschaft haben. Isolierungsfestigkeit: 0.6/1KV
All cables must have an approval of the relevant classification society. Insulating strength: 0.6/1KV

Date

GEA WSPN Standard: Nexans MPRX 0.6/1kV.

WD-Kabel
WD-cable

Energiekabel < 1kV


Energy cable < 1kV

WE-Kabel
WE-cable

Erdungs-/Potentialausgleichsleiterleiter
Earth-/ Equipotential bonding conductor

WF-Kabel
WF-cable

Datenbus
Data bus

WG-Kabel
WG-cable

Steuer-/ Messkabel
Control-/measuring cable

WH-Kabel
WH-cable

Lichtwellenleiter
Optical fibre

Legende Kabeltypen (Kabelliste)


Legend cable typ (list of cables)

-J

Kabel / Leitung mit Schutzleiter


Cable / conductor with protective conductor

FC.CY

Motorkabel FU mit konzentrischem Auenleiter (PE)


Motor cable FC with concentric outer (PE)

-O

Kabel / Leitung ohne Schutzleiter


Cable / conductor without protective conductor

PL

Potentialausgleichsleiter
Equipotential bonding conductor

CY-J

Kabel / Leitung mit Schutzleiter geschirmt


Cable / conductor with protective conductor screened

Ex-CY

Steuerleitung blau fr eigensichere Stromkreise


Control line blue for intrinsically safecircuits

CY-O

Kabel / Leitung ohne Schutzleiter geschirmt


Cable / conductor without protective conductor screened

CY-TP

Datenleitung paarverseilt
Data line twisted pair

FC.CY-J

Motorkabel FU geschirmt mit Schutzleiter


Motor cable FC screened with protective conductor

Date
Editor
Tested
Changes

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Hinweise zur Installation


Instructions for installation

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMB

Bl./Sh.
50
67 Bl./Sh.

FU
FC

Generelle Information zum Potentialausgleich.


Die Informationen auf diesem Blatt sind nicht
kundenspezifisch angepasst.

=..-U.

IP54

General Information for the equipotential bonding system.


Please note, that the information shown on this page are
not customised.

10 mm
GN YE

PE-Schiene
protective earth - rail

IDM
25 mm
GN YE

10 mm
GN YE

PA

PA1

PA2

PA3

PA4

PA5

PA6

PA7

Potentialausgleichsschiene
equipotential bonding strip

Potentialausgleich Gebude
equipotential bonding building

10 mm
GN YE

25 mm
GN YE

Fundamenterder
foundation earth

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Potentialausgleich Separator
Potential equalization Separator

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMB

Bl./Sh.
51
67 Bl./Sh.

Changes
Date
Name
Date
Editor
Tested
04.03.2011
BEE/PLE
04.03.2011 KA
Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

=100-WG004

SC
SC

GLAND

GLAND

GLAND

GLAND

X
X
X
X
X

SC
SC

MPRXCX 2x1,5 mm

=100-WG004

MPRXCX 2x1,5 mm

=100-WG003

MPRXCX 2x1,5 mm

=100-WG002

MPRXCX 2x1,5 mm

=100-WG001

MPRXCX 2x1,5 mm

-PE

&EFS/21.5

&EFS/21.4

&EFS/21.2

&EFS/21.1

&EFS/19.2

&EFS/18.7

&EFS/18.2

&EFS/16.3

&EFS/14.3

&EFS/13.4

&EFS/13.4

TAL Temperatur Alarm min


TAL temperature alarm min

=100-WG003

SC
SC

TAH Temperatur Alarm max


TAH temperature alarm max

=100-WG002

SC
SC

Wasserschlossalarm
Water seal broken alarm

=100-WG001

GLAND
SC
GLAND

GLAND

-PE

-PE

-PE

-PE

&EFS/12.2

Sammelstrung
Common failure

SC
SC

=11-WG005

=11-WG005

MPRXCX 7x1,5 mm

GLAND

GLAND

=01-WG011

GLAND

Rckmeldung Zulaufpumpe
Feed back feed pump

SC
GLAND

=01+JB-1X10_GLAND

GLAND

MPRXCX 2x1,5 mm

=01-WG010

MPRXCX 7x1,5 mm

GLAND

Wasserabfuhrventil
Water discharge valve

=01-WG010

SC
SC

=01-WG004

MPRXCX 4x1,5 mm

=01-WG009

MPRXCX 2x2,5 mm

=01-WG007

GLAND

-PE

&EFS/10.1

Zulaufventil
Feed valve

=01+JB-1X10_GLAND

SC
SC

Wasserabfuhr
Water monitoring system

SC
SC

=01-WG009

=01-WG007

MPRXCX 2x1,5 mm

=01-WG006

GLAND

-PE
1

Separator Strung
Separator failure

Entleerungsberwachung
Ejection monitoring

=01-WG006

SC
SC

Separator Aus
Separator off

SC
SC
MPRXCX 2x1,5 mm

-WG008

GLAND

Ziel intern
Target intern

MPRXCX 2x2,5 mm

-WD001

Klemmennummer
Terminal number

-WG008

-WD001

Querverweis
Cross reference

Separator Not-Halt
Separator emergency stop

Einspeisung
Incoming

=0+-GLAND
0
5
6

Benennung/Description:

Klemmenanschlussplan =0+-GLAND
Terminal connecting plan =0+-GLAND

Sprache:
Language:

de/en
Zeichnungs Nr.:
Drawing No.:
9

Brcken
Bridges

SC
SC

GLAND

Rev.01 =
As built +

8106-2004-059
DCC

& EMC

Bl./Sh.
52
67 Bl./Sh.

A2

-T2

Klemmennummer
Terminal number

Brcken
Bridges

=0+-24M

Ziel intern
Target intern

BU
13

GN/YE
PE

Name

=01-X2
Steuerspannung DC
Control voltage DC
Date
Editor
Tested
Date

PE

-PE

13

Changes

=01-K1

Querverweis
Cross reference

&EFS/11.6

&EFS/11.6

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =0+-24M
Terminal connecting plan =0+-24M

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMC

Bl./Sh.
53
67 Bl./Sh.

&EFS/23.6

-24M

-PE

-PE

Ziel intern
Target intern

-PE

&EFS/11.6

&EFS/11.6

&EFS/10.6

&EFS/10.6

&EFS/10.6

Querverweis
Cross reference

&EFS/10.5

&EFS/10.3

PE

PE

PE

PE

PE

PE

PE

SC

GN/YE
PE
L

GN/YE
PE

GN/YE
PE

GN/YE
PE

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

PE

PE

Steuergert
Timing unit

-PE
Steuerspannung DC
Control voltage DC

-1G
Erdung Gehuse 1
Earthing cabinet 1

Erdung Tr 1
Earthing door 1

Erdung Montageplatte 1
Earthing mounting plate 1

-1M

-1T

PE

Filterlfter
Filter fan

-M1

-SC
Erdung Schirm
Earthing screen
Changes

PE

M
1~

SC

Date
Editor
Tested

N
N

Klemmennummer
Terminal number

PE

=0+-PE

Brcken
Bridges

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =0+-PE
Terminal connecting plan =0+-PE

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMC

Bl./Sh.
54
67 Bl./Sh.

-SC

Ziel intern
Target intern

-SC

Querverweis
Cross reference

&EFS/20.7

&EFS/10.3

SC

Klemmennummer
Terminal number

SC

=0+-SC

Brcken
Bridges

PE

SC

Date

Name

min / max Temperaturberwachung


Min / max temperature monitoring

Erdung Schirm
Earthing screen
Date
Editor
Tested
Changes

SC

=11-X2

-PE

PE

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =0+-SC
Terminal connecting plan =0+-SC

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMC

Bl./Sh.
55
67 Bl./Sh.

&EFS/10.5

&EFS/10.5

-S1

23

&EFS/10.4

&EFS/10.4
-S1

13

-F1

Ziel intern
Target intern

-F1

Querverweis
Cross reference

&EFS/10.1

&EFS/10.1

2
2

RD
L

RD/WH
PE

-WD001
1
L1

MPRXCX 2x2,5 mm

Klemmennummer
Terminal number

=0+-X1

Brcken
Bridges

PE

M
1~

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Filterlfter
Filter fan

Reserve
Spare

Einspeisung
Incoming

-M1

=Customer+L-X

L1

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =0+-X1
Terminal connecting plan =0+-X1

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMC

Bl./Sh.
56
67 Bl./Sh.

=MCC-X

Ziel intern
Target intern

=MCC-X

Querverweis
Cross reference

&EFS/12.1

&EFS/12.1

2
-WG008

MPRXCX 2x1,5 mm

Klemmennummer
Terminal number

=0+-X2

Brcken
Bridges

Date
Editor
Tested
Changes

Date

Name

Separator Not-Halt
Separator emergency stop

=MCC-X

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =0+-X2
Terminal connecting plan =0+-X2

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMC

Bl./Sh.
57
67 Bl./Sh.

-T1
-WG007

MPRXCX 2x2,5 mm

Klemmennummer
Terminal number

Brcken
Bridges

=01+-X1

Ziel intern
Target intern

-T1

Querverweis
Cross reference

&EFS/13.4

&EFS/13.4

Date
Editor
Tested
Changes

Date

Name

Entleerungsberwachung
Ejection monitoring

=MCC-X_

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =01+-X1
Terminal connecting plan =01+-X1

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMC

Bl./Sh.
58
67 Bl./Sh.

Changes
Date
Editor
Tested

Date
Name
04.03.2011
BEE/PLE
04.03.2011 KA
Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

2
12
3
15

7
4
16
5
18
6
17

Benennung/Description:

Klemmenanschlussplan =01+-X2
Terminal connecting plan =01+-X2

3
MPRXCX 4x1,5 mm

-WG009

MPRXCX 7x1,5 mm

-WG011

21

20

19

18

17

16

15

14

13

12

11

10

=00-K1

=00-K1

=00-K1

=00-K1

=00-K1

=00-K1

=0-24M

=00-K1

=00-K1

=00-K1

=11-X2

=00-K1

X11:2

X11:1

X12:6

X12:5

X12:2

X12:3

X12:1

X11:16

X11:6

X13:8

&EFS/14.2

&EFS/14.1

&EFS/18.7

&EFS/18.6

&EFS/18.5

&EFS/18.4

&EFS/18.4

&EFS/18.3

&EFS/18.1

&EFS/18.1

&EFS/17.4

&EFS/16.3

&EFS/16.3

&EFS/16.2

&EFS/16.2

&EFS/16.1

&EFS/16.1

Separator Strung
Separator failure

=MCC

Separator Betrieb
Separator operation

Wasserabfuhrventil
Water discharge valve

+
MPRXCX 2x1,5 mm

-WG010

MPRXCX 7x1,5 mm

-WG011

MPRXCX 7x1,5 mm

-WG004

MPRXCX 4x1,5 mm

-WG009

X13:5

&EFS/15.2

&EFS/15.2

&EFS/13.4

Kreislaufventil
Circulation valve

6
1
10

Verdrngungs- und Fllwasser


Displacem- and filling water

+JB-1X10

Steuerwasser
Operating water

-*8_7_002

1
MPRXCX 7x1,5 mm

-WG004

=00-K1

=0-X2

2-

1+

12

&EFS/13.4

Zulaufventil
Feed valve

Reserve
Spare

+JB-1X10

Wasserabfuhr
Water monitoring system

=MCC

4
MPRXCX 4x1,5 mm

-WG009

-T2

-T2

-K1

11

Separator Strung
Separator failure

+JB-1X10

Schlammraumberwachung
Sludge space monitoring

=MCC

1
MPRXCX 7x1,5 mm

-WG004

-K1

Separator Betrieb
Separator operation

Reinoel Ablaufdruck
Clean-oil discharge pressure

+JB-1X10

MPRXCX 2x1,5 mm

-WG006

Klemmennummer
Terminal number
1

Ziel intern
Target intern

Drehzahlberwachung
Speed monitoring device

=MCC-X_

Querverweis
Cross reference

Separator Aus
Separator off

=01+-X2
0
6
7

Sprache:
Language:

de/en
Zeichnungs Nr.:
Drawing No.:
9

Brcken
Bridges

12

Rev.01 =
As built +

8106-2004-059
DCC

& EMC

Bl./Sh.
59
67 Bl./Sh.

Changes
Date
Name
Date
Editor
Tested
04.03.2011
BEE/PLE
04.03.2011 KA
Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

1
+
2
8
1

1
MPRXCX 3x1,5 mm

-WG122

MPRXCX 2x1,5 mm

-WG106

MPRXCX 2x1,5 mm

-WG105

2
10

PE

18

17

16

15

14

13

12

-PE

-X2

-X2

-X2

-X2

-X2

-X2

-X2

-X2

18

19

17

15

14

11

10

&EFS/18.4

&EFS/18.6

&EFS/18.7

&EFS/18.5

&EFS/18.4

&EFS/18.4

&EFS/18.3

&EFS/18.3

&EFS/17.1

&EFS/17.4

&EFS/17.3

&EFS/17.1

&EFS/16.3

&EFS/16.2

&EFS/16.1

&EFS/16.1

&EFS/16.1

&EFS/15.2

&EFS/15.2

Verdrngungs- und Fllwasser


Displacem- and filling water

Wasserabfuhrventil
Water discharge valve

+SB-1X20

Kreislaufventil
Circulation valve

-*9_7_005

11

10

-X2

-X2

-X2

Verdrngungs- und Fllwasser


Displacem- and filling water

-*9_7_004

Steuerwasser
Operating water

2
MPRXCX 4x1,5 mm

-X2

Reserve
Spare

BU

Wasserabfuhr
Water monitoring system

Schlammraumberwachung
Sludge space monitoring

BN

-WG121

.-O 2x0,34 mm

-WG101

&EFS/16.4

&EFS/18.3

+SB-1X20

Reinoel Ablaufdruck
Clean-oil discharge pressure

-*0_9_020

-PE

Ziel intern
Target intern

Drehzahlberwachung
Speed monitoring device

PE

Klemmennummer
Terminal number
PE

Querverweis
Cross reference

Wasserabfuhr
Water monitoring system

Steuerwasser
Operating water

=01+JB-1X10
0
5
6

Benennung/Description:

Klemmenanschlussplan =01+JB-1X10
Terminal connecting plan =01+JB-1X10

Sprache:
Language:

de/en
Zeichnungs Nr.:
Drawing No.:
9

Brcken
Bridges

3
11

Rev.01 =
As built +

8106-2004-059
DCC

& EMC

Bl./Sh.
60
67 Bl./Sh.

&EFS/18.4

&EFS/18.3

=0-GLANDGLAND

=0-GLANDGLAND

Ziel intern
Target intern

-WG106

SC
SC

SC
SC

PE

SC
SC
PE:PE PE:PE

MPRXCX 2x1,5 mm

GLAND

MPRXCX 2x1,5 mm

GLAND

-WG105

MPRXCX 3x1,5 mm

GLAND
-WG122

Klemmennummer
Terminal number

MPRXCX 4x1,5 mm

GLAND

Brcken
Bridges

-WG121

=01+JB-1X10_GLAND

Querverweis
Cross reference

&EFS/18.7

&EFS/16.3

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

-WG106
Verdrngungs- und Fllwasser
Displacem- and filling water

Steuerwasser
Operating water

Wasserabfuhrventil
Water discharge valve

Wasserabfuhr
Water monitoring system

-WG105

+SB-1X20

PE

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =01+JB-1X10_GLAND
Terminal connecting plan =01+JB-1X10_GLAND

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMC

Bl./Sh.
61
67 Bl./Sh.

Changes
Date
Name
Date
Editor
Tested
04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

P
-

BN
+
BU

I
PE

-*0_7_011

BU

PE

PE

PE

11

X
X

PE
PE

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.
.-J 3x0,75 mm

-WG205

.-J 3x0,75 mm

-WG204

.-J 3x0,75 mm

-WG205

10

18

17

16

+JB-1X10_GLAND
GLAND

+JB-1X10_GLAND
GLAND

+JB-1X10

+JB-1X10

+JB-1X10

+JB-1X10

+JB-1X10

&EFS/18.7

&EFS/18.6

&EFS/18.6

&EFS/18.7

&EFS/18.5

&EFS/18.5

&EFS/16.3

&EFS/16.3

&EFS/16.3

&EFS/16.2

&EFS/16.2

&EFS/16.1

&EFS/16.1

Wasserabfuhrventil
Water discharge valve

-*0_7_010

BN

Kreislaufventil
Circulation valve

-*0_7_011

GY
.-J 3x0,75 mm

-WG204

.-O 3x0,75 mm

+JB-1X10

Wasserabfuhrventil
Water discharge valve

BN

Kreislaufventil
Circulation valve

BK
A/Q

-WG203

.-O 2x0,34 mm

-WG202

+JB-1X10

BK

A/Q

WH

-*0_7_010

-*0_9_013

BK

Wasserabfuhr
Water monitoring system

WH

-*0_9_014

2
.-O 2x0,34 mm

-WG201

Klemmennummer
Terminal number

Ziel intern
Target intern

Schlammraumberwachung
Sludge space monitoring

-*1_9_002

Querverweis
Cross reference

Reinoel Ablaufdruck
Clean-oil discharge pressure

=01+SB-1X20
0
4
5

Benennung/Description:

Klemmenanschlussplan =01+SB-1X20
Terminal connecting plan =01+SB-1X20

6
7

Sprache:
Language:

de/en
Zeichnungs Nr.:
Drawing No.:
9

Brcken
Bridges

PE
PE

Rev.01 =
As built +

8106-2004-059
DCC

& EMC

Bl./Sh.
62
67 Bl./Sh.

&EFS/21.5

-K4

14

&EFS/21.5
-K4

11

&EFS/21.4
-K3

14

&EFS/21.3
-K3

11

&EFS/21.2
-K2

14

&EFS/21.2
11
-K2

14

-K1

8
-WG004

MPRXCX 2x1,5 mm

6
-WG003

MPRXCX 2x1,5 mm

4
MPRXCX 2x1,5 mm

3
2

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

TAL Temperatur Alarm min


TAL temperature alarm min

TAH Temperatur Alarm max


TAH temperature alarm max

Wasserschlossalarm
Water seal broken alarm

Sammelstrung
Common failure

=Customer+L-X

-WG002

-WG001

MPRXCX 2x1,5 mm

Klemmennummer
Terminal number

Brcken
Bridges

=100+-X2

Ziel intern
Target intern

-K1

11

Querverweis
Cross reference

&EFS/21.1

&EFS/21.1

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =100+-X2
Terminal connecting plan =100+-X2

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMC

Bl./Sh.
63
67 Bl./Sh.

&EFS/20.7

SC

&EFS/20.6

=0-SC

=00-K1

X13:16

&EFS/20.6

=MCC

=MCC

SC

5
2

3
3

4
4

.CY-O 4x1,5 mm

-WG003

-WG005

MPRXCX 2x1,5 mm

Klemmennummer
Terminal number

Brcken
Bridges

=11+-X2

Ziel intern
Target intern

=00-K1

X13:15

&EFS/20.5

&EFS/20.5

Querverweis
Cross reference

&EFS/19.1

&EFS/19.1

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

min / max Temperaturberwachung


Min / max temperature monitoring

Reserve
Spare

Rckmeldung Zulaufpumpe
Feed back feed pump

-*0_9_006

=MCC

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Klemmenanschlussplan =11+-X2
Terminal connecting plan =11+-X2

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EMC

Bl./Sh.
64
67 Bl./Sh.

Stckliste
Parts list
Funktionszeichen
Function sign

/Seite.Pfad
/page.path

=0-F1

&EFS/10.1

WS Teil - Nr.
WS part - no.

Hersteller Bestell-Nr.
Manufacturer order no..

Bezeichnung
Name

Hersteller
Manufacturer

0005-1551-010

566556

Sicherungsautomat, C 6A , 2 pol

AEG

Circuit breaker
=0-M1

&EFS/10.4

0005-1409-320

116 22 10 1 055

Filterlfter, 207-253V, 50/60Hz, 19/18W, 44/52m/h, IP54, RAL 7035

Pfannenberg

Filter fan
=0-M1

&EFS/10.4

0005-1409-230

117 20 00 1 055

Austrittsfilter

Pfannenberg

Discharge filter
=0-S1

&EFS/10.1

0005-1439-000

3SB3000-2KA21-DC

Schwenksteller komplett, rastend, rot, 0-I, 1x 2NO + 1x1NC

Plenge

Selector switch complete


=0-X1

&EFS/10.1;

2002-1201

2002-1201

2-Leiter-Durchgangsklemme 0,08-2,5mm

Wago

2-Conductor through terminal block


=0-24M

&EFS/11.6

0005-4708-890

1031400000

Durchgangs-Reihenklemme, 1,5 mm, Schraubanschluss, Wemid, dunkelbeige, TS 35

Weidmueller

Feed-through terminal
=0-P1

&EFS/11.8

0005-4396-040

3SB3001-6AA60

VORSATZ, RUND LEUCHTMELDER LINSE WEISS MIT HALTER

Siemens

INDICATOR LIGHT WITH HOLDER, SMOOTH LENS LENS WHITE


=0-P1

&EFS/11.8

3SB3400-1RE

3SB3400-1RE

LAMPENFASSUNG MIT INTEGRIERTER LED, AC 230V, WEISS

Siemens

LAMPHOLDER WITH INTEGRATED LED, 230V AC, WHITE


=0-P1

&EFS/11.8

3SB3922-0AV

3SB3922-0AV

SCHILDTRAEGER FLACH, FUER BEZEICHNUNGSSCHILD 12,5 X 27MM

Siemens

FLAT HOLDER FOR INSCRIPTION PLATE 12.5 X 27 MM


=0-P1

&EFS/11.8

3SB1901-2AA

3SB1901-2AA

BEZEICHNUNGSSCHILD, SILBERFARBEN, FR SELBSTBESCHRIFTUNG, 12,5x27MM

Siemens

LABEL
=0-T2

&EFS/11.5

0005-1407-020

6EP1333-2AA01-0AA0

Einphasennetzgeraet Prim.: 120/230V, 50/60Hz, Sec.: 24VDC, 5A

Siemens

Single phase power supply


=0-X2

&EFS/12.1

2002-1201

2002-1201

2-Leiter-Durchgangsklemme 0,08-2,5mm

Wago

2-Conductor through terminal block


=01-T1

&EFS/13.5

0005-3482-070

1073490000

Stromberwachung, 0...1 A AC/ 0...5 A AC/ 0...10 A AC , 1 , 0(4)...20 mA , 0...10 V , 1

Weidmueller

Current monitoring
=01-X1

&EFS/13.4

2002-1201

2002-1201

2-Leiter-Durchgangsklemme 0,08-2,5mm

Wago

2-Conductor through terminal block


=01-X2

&EFS/13.4;

2002-1201

2002-1201

2-Leiter-Durchgangsklemme 0,08-2,5mm

Wago

2-Conductor through terminal block


=01-K1

&EFS/14.4

0005-4033-040

2966171

Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24

Phoenix Contakt

Relay single contact


=01-T2

&EFS/15.1

0005-4509-000

KCD2-E2

Sensor-Endstufenklemme, Eingang fr NAMUR-Sensoren, 24V DC Speisespannung

Pepperl & Fuchs

Converters- Amplifier to convert NAMUR sensor


=11-X2

&EFS/19.1;

2002-1201

2002-1201

2-Leiter-Durchgangsklemme 0,08-2,5mm

Wago

2-Conductor through terminal block


=100-K1

&EFS/21.1

0005-4033-040

2966171

Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24

Phoenix Contakt

Relay single contact


Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Stckliste
Parts list

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EPB

Bl./Sh.
65
67 Bl./Sh.

Stckliste
Parts list
Funktionszeichen
Function sign

/Seite.Pfad
/page.path

=100-K2

&EFS/21.2

WS Teil - Nr.
WS part - no.

Hersteller Bestell-Nr.
Manufacturer order no..

Bezeichnung
Name

Hersteller
Manufacturer

0005-4033-040

2966171

Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24

Phoenix Contakt

Relay single contact


=100-K3

&EFS/21.3

0005-4033-040

2966171

Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24

Phoenix Contakt

Relay single contact


=100-K4

&EFS/21.5

0005-4033-040

2966171

Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24

Phoenix Contakt

Relay single contact


=100-X2

&EFS/21.1..

2002-1201

2002-1201

2-Leiter-Durchgangsklemme 0,08-2,5mm

Wago

2-Conductor through terminal block


=00-K1

&EFS/23.1

0005-4050-430

6ES7613-1SB02-0AC0

Komplettgert GEA, C7-613, 24DE/16DA/5AE/2AA, SIMATIC C7

Siemens

Control system GEA, C7-613, 24DI/16DO/5AI/2AO, SIMATIC C7


-Cabinet

&ELU/27.1

1338500

1338500

Kompakt-Schaltschrank AE, lackiert RAL 7035, mit Montageplatte, eintrig

Rittal

Compact enclosure AE, painted RAL 7035, with mount. plate, single door
-Cabinet

&ELU/27.1

2508000

2508000

Wandbefestigungshalter Stahlblech, Wandabstand 10mm

Rittal

Wall mounting bracket sheet steel, zinc-plated & passivated wall distance 10 mm
-Cabinet

&ELU/27.1

0005-1412-000

2519000

Trarretierung fr das AE Programm

Rittal

Door stay for the AE range


-Cabinet

&ELU/27.1

2510000

2510000

Schaltplantaschen aus Kunststoff Din A4

Rittal

Wiring plan pockets of plastic Din A4


-Cabinet

&ELU/27.1

Lack_AE1030-1338

Lack_AE1030-1338

Lackierung AE-Schrank

Plenge

Painting
-Cabinet

&ELU/27.1

8556-9999-000

KLEINMATERIAL

Kleinmaterial Schaltschrank

Plenge

Incidentals control cabinet


-Cabinet

&ELU/27.1

RESOPALSCHILD100/130 RESOPALSCHILD100/130 Resopalschild

Kaiser

Resopal plate
-Cabinet

&ELU/27.1

4568000

4568000

Transportsen fr PS/ES und TS

Rittal

Eyebolts for PS/ES and TS


-Cabinet

&ELU/27.1

ADERKENNZEICHNUNG

ADERKENNZEICHNUNG

Aderkennzeichnung

Plenge

Wire marking
-Cabinet

&ELU/27.1

Halogenfreie Kanle

Plenge

Halogen free Channels


-Cabinet

&ELU/27.1

Halogenfreie Verdrahtung

Plenge

Halogen free Wiring


-Ground_plate

&ELU/28.1

0005-4515-600

11-24-000-200-12

Verschraubung, Z12-A6A, 10-12,5mm

Heinrich

cable gland
-Ground_plate

&ELU/28.1

0005-4516-600

11-24-000-200-14

Verschraubung, Z14, 12-14,5mm

Heinrich

cable gland
-Ground_plate

&ELU/28.1

0005-4443-630

81-20-802-0001-04

Blindstopfen Messing, M20x1,5

Jacob

Blanking plug brass nickeled


Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Stckliste
Parts list

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EPB

Bl./Sh.
66
67 Bl./Sh.

Stckliste
Parts list
Funktionszeichen
Function sign

/Seite.Pfad
/page.path

-Ground_plate

&ELU/28.1

WS Teil - Nr.
WS part - no.

Hersteller Bestell-Nr.
Manufacturer order no..

Bezeichnung
Name

Hersteller
Manufacturer

22-20-02-2

22-20-02-2

EMV-Gegenmutter M20/EMV

Heinrich

EMV-Counter nut
=Additions

&ELU/28.8

0005-1554-000

1646461044

Kabelbezeichnung, polyamid

Weidmueller

Cable designation
=Additions

&ELU/28.8

8555-9001-010

8555-9001-010

Betriebsanleitung D10 NewDesign, englisch

WS Mineraloil Systems

Instruction manual
=Additions-S01

&ELU/30.1

0005-0081-030

3SB3801-0DF3

Pilzdrucktaster Gehuse, verrastend, mit Schutzkragen, 1NC, 2x M20

Siemens

Mushroom push button box


=Additions-S01

&ELU/30.1

0005-4515-600

11-24-000-200-12

Verschraubung, Z12-A6A, 10-12,5mm

Heinrich

cable gland
=Additions-S01

&ELU/30.1

22-20-02-2

22-20-02-2

EMV-Gegenmutter M20/EMV

Heinrich

EMV-Counter nut
=Additions-B1

&ELU/31.2

0005-0924-220

TAID10B500

Stromwandler, 50/1A

IME

Current transformer
=Additions-F1

&ELU/32.2

0005-1100-070

3RN1010-1CM00

THERMISTOR-MOTORSCHUTZ, STANDARD-AUSWERTEGERT, AUTO, 1S+1OE, AC 230V

Siemens

THERMISTOR MOTOR PROTECTION STANDARD EVALUATION UNIT AUTO, 1NO+1NC, AC

Date
Editor
Tested
Changes

Date

Name

04.03.2011
BEE/PLE
04.03.2011 KA

Kunde:
Customer:
Projekt:
Project:

GEA Westfalia
Separator

This document is COPYRIGHTED by GEA Westfalia Separator Production GmbH. All rights being reserved.

Benennung/Description:

Stckliste
Parts list

Rev.01 =
As built +

Sprache:
Language:

de/en

Zeichnungs Nr.:
Drawing No.:

DCC

8106-2004-059

& EPB

Bl./Sh.
67
67 Bl./Sh.

Commissioning Equipment,
Tools and Spare Parts List
LO
OSE 20-0196-067

Quantity
2
1

Part no.:
2064-9769-020
2064-9901-000

Description
Set of commissioning equipment
Set of tools and accessories

A company of GEA group


Note: SUBJECT TO ODIFICATION

Part no. 2064-9769-020

Packing list of accessories :

2064-9769-020

SET OF COMMISSIONING EQUIPMENT

Pos.

Part no.

Part description

Quantity Unit of Qty

0010

0007-1936-750

Gasket

PC

0020

0007-2925-750

Gasket

PC

0030

0007-2485-600

Gasket

PC

0040

0007-1904-750

Gasket

PC

0050

0007-1936-750

Gasket

PC

0060

0007-1861-750

Gasket

PC

0070

0007-1987-750

Gasket

PC

0080

0015-0003-080

Lubricating oil ( for initial filling oil )

PC

0090

0021-3337-900

Drive belt

PC

0095

0015-0082-000

Lubricating grease

PC

Part no. 2064-9901-000

Packing list of accessories :

2064-9901-000

SET OF TOOLS AND ACCESSORIES

Pos.

Part no.

Part description

Quantity Unit of Qty

0010

0003-0644-300

Mallet

PC

0015

0003-0596-320

Socket wrench, compl

PC

0020

0003-3796-320

Offset screwdriver

PC

0030

0003-3685-000

Double hook wrench, compl

PC

0040

0013-0279-300

Hexagon nut

PC

0050

0019-6959-300

Hex head screw

PC

0060

0026-0356-300

Washer/ disk

PC

0070

2064-9982-000

Eye bolt, compl

PC

0080

2064-9822-000

Bell-shaped piece

PC

0090

2064-9860-000

Mounting tool, compl

PC

0100

2064-9943-000

Annular wrench, compl

PC

0110

2064-9823-000

Mounting ring

PC

0120

0018-2916-050

Double nipple

PC

0130

0019-6340-300

Threaded pin

PC

0140

2058-9939-000

Washer/ disk

PC

0150

2142-9935-000

Pressure piece

PC

0160

0013-0280-300

Hexagon nut

PC

0170

0019-6994-300

Hex head screw

PC

You might also like