BILLOFQUANTITYFORTHEHVACWORKSOF

TheInstituteofspacetechnology,nearTollPlaza(G.T.Road,)Islamabad
PLEASEMARKTICKONLEFTBOXWHICHEQUIPMENTYOUHAVEQUOTED

PROPOSALBASEDONCHINESEEQUIPMENT
PROPOSALBASEDONJAPANESE,KORIANORMALAYSIANEQUIPMENT
Sr

Description

Qty

Unit

Rate

Amount

ACU#1capacity18tons
ACU#2capacity32tons
ACU#3capacity25tons
ACU#4capacity24tons
ACU#5capacity24tons
ACU#6capacity24tons
ACU#7capacity14tons
ACU#8capacity36tons
ACU#9capacity31.5tons
ACU#10capacity32tons
ACU#11capacity35.5tons
ACU#12capacity24tons
ACU#13capacity32.5tons
ACU#14capacity33.5tons
ACU#15capacity39tons

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.

Supplyandinstallationoffreshairspecial
typeAirCooledSelfContainedair
Conditioningunitcapacityhavingof30
tonswithsteamhumidifiercompletewith
allaccessoriesasperscheduleoftechnical
particular&shownonthedrawingsoras
approvedbytheEngineer/Consultant.

No.

Supplyandinstallationoffollowingair
cooledMultiDigitalScroll(MDS)Reversible
(Heat&Cool)typeoutdoorair
conditioningunitcompletewithall
accessoriesasperscheduleoftechnical
particular&asshownonthedrawingsand
asapprovedbytheEngineer/Consultant:

Sr

Description
SupplyandinstallationoffollowingIndoor
DXCeilingdecorativeFanCoilUnit(FCU)
includingappropriatesizecopperpiping
betweenindoorandoutdoorunit
completewithallaccessoriesasper
scheduleoftechnicalparticularshownon
thedrawing#1,includingexpectionvalves
andyconnectorsandorasapprovedby
theEngineer/Consultant.
Basementfloor
CeilingsuspendedCassettetype
Cooling/HeatingunitCoolingcapacity2
tonsUnit#1to25.
LowerGroundFloor
WallmountedtypeCooling/Heatingunit
Coolingcapacity1.5tonsUnit#26to41.
CeilingsuspendedCassettetype
Cooling/HeatingunitCoolingcapacity2
tonsforLowerGroundFloorUnit#42to
43.
CeilingsuspendedCassettetype
Cooling/HeatingunitCoolingcapacity1.5
tonsforLowerGroundFloorUnit#44to
57.
WallmountedtypeCooling/Heatingunit
Coolingcapacity1.5tonsforLowerGround
FloorUnit#58to73.
UpperGroundFloor
CeilingsuspendedCassettetype
Cooling/HeatingunitCoolingcapacity1.5
tonsUnit#74to84.
CeilingsuspendedCassettetype
Cooling/HeatingunitCoolingcapacity2
tonsUnit#85to92.
CeilingsuspendedCassettetype
Cooling/HeatingunitCoolingcapacity1.0
tonUnit#93to94.

Qty

Unit

25

No.

16

No.

No.

14

No.

16

No.

11

No.

No.

No.

Rate

Amount

Sr
3

Description
CeilingsuspendedCassettetype
Cooling/HeatingunitCoolingcapacity2
tonsUnit#95to125.
CeilingsuspendedCassettetype
Cooling/HeatingunitCoolingcapacity1.0
tonUnit#126to127.
CeilingsuspendedCassettetype
Cooling/HeatingunitCoolingcapacity2
tonsUnit#128to140.
FirstFloor
CeilingsuspendedCassettetype
Cooling/HeatingunitCoolingcapacity2
tonsUnit#141to151.
CeilingsuspendedCassettetype
Cooling/HeatingunitCoolingcapacity1
tonsUnit#152.
CeilingsuspendedCassettetype
Cooling/HeatingunitCoolingcapacity2
tonsUnit#153to157.
VerticalFloorstandingtypeCooling/
HeatingunitCoolingcapacity1.5tonsUnit
#158A,158B,159A,159B,160A&160
B.
CeilingsuspendedCassettetype
Cooling/HeatingunitCoolingcapacity2
tonsUnit#161to163.
CeilingsuspendedCassettetype
Cooling/HeatingunitCoolingcapacity1.5
tonsUnit#164to165.
CeilingsuspendedCassettetype
Cooling/HeatingunitCoolingcapacity2
tonsUnit#166to193.
ScondFloor
CeilingsuspendedCassettetypeCooling
/HeatingunitCoolingcapacity2tonsUnit
#194to205.
CeilingsuspendedCassettetypeCooling
/HeatingunitCoolingcapacity1.5tons
Unit#206to209.

Qty

Unit

32

No.

No.

13

No.

11

No.

No.

No.

No.

No.

No.

28

No.

12

No.

No.

Rate

Amount

Sr

Description
CeilingsuspendedCassettetypeCooling
/HeatingunitCoolingcapacity2tonsUnit
#210to228.
Supplyandinstallationofsheetmetal
ductingcompleteinallrespectasshown
onthedrawings,completewith
accessorieshangers,supports&as
approvedbytheEngineer/Consultant:
22Guage
24Guage
26Guage
Supply&installationoffollowing
AluminiumFoilFiberGlass16kg/m3
density)insulationwrappedwith
Aluminiumtapeandshallbeprotected
with8ozcanvas,completeinallrespectas
shownonthedrawings&asshownonthe
drawingsasasapprovedbythe
engineer/consultant:
Soundliner1''thick
Thermalinsulation1''thick
Thermalinsulation2''thick
Supply&installationofRefnetY
Connectorsasperspecificationand
thicknessshallnotbelessthan18guage
(includepriceinitem#3)
SupplyandInstallationofrefrigerantpipes
typeLthicknessnotlessthan20gauge
(Liquid+Gas)withexpandedrubberfoam
insulationforMultiSplittypeA/Cunits
fromeachFCUtooutdoorunitsinstalled
onrooftop,includingcontrolwirring,
Flushing,gascharging,hangers,supports
andbracketsoffollowingsizesall
refrigerantpipesshouldbeinPVCDura
Ductasapprovedbythe
Engineer/consultant:
6.35mmxt0.8
9.52mmxt0.8

Qty

Unit

24

No.

2500
18528
1250

Sq.ft
Sq.ft
Sq.ft

2860
17150
1860

Sq.ft
Sq.ft
Sq.ft

Lot

1450
1850

Rft
Rft

Rate

Amount

Sr

Description
12.7mmxt1.0
15.88mmxt1.2
19.05mmxt1.2
28.6mmxt1.2
41.3mmxt1.6
34.9mmxt1.4
22.2mmxt1.2

SupplyandInstallationofPVCcondensate
drainpipewithinsulationfromeachFCU
tocondensatetankinbasement)complete
inallrespectreadytooperateasapproved
bytheEngineer/Consultant

supply&installationofCommunication
9 cablebetweenallindoorunitsand
outdoorunitscompleteinallrespect,as
approvedbytheEngineer/Consultant.
SupplyandinstalltionofAluminium
Registersforsupplyoffreshairand
exhaustairoffollowingsizes,completein
allrespect,supportandotheraccessories
etc.Make:SteelCraft,asapprovedbythe
Consultant:
10
ForBasementfloorSAD24"x6"
ForLowerGroundFloorSAD24''x6''
ForUpperGroundfloorSAD24''x6''
ForFirstFloorSAD24''x6''
ForFirstFloorSAD24''x12''
ForSecondFloorSAD24''x3''
SupplyandInstallationofElectronicExpan
sionvalve(EXV)aspermanufacturer's
11 recommwndationandapprovedbythe
Engineer/consultantincludeinindoorunits
item#3.

Qty

Unit

1450
3320
702
710
270
650
100

Rft
Rft
Rft
Rft
Rft
Rft
Rft

Lot

Lot

3
3
9
22
12
9

No.
No.
No.
No.
No.
No.

Lot

Rate

Amount

Sr

Description

SupplyandinstallationofBestqualityPVC
watertank500gallons(normallyusedas
overheadtank)forcondensateincluding
12 levelautomaticcontrollerwithupperand
lowerlevelsensorcompleteinallrespect
locationisintheliftwellonbasementas
approvedbytheEngineer/consultant.
Supply&installationofCentrifugalPump
25gpmagainst(20fthead)asspecified
suitabletothrowcondensatewater
13 collectedinthetankfrombasementto
lowergroundfloorinopenspaceasshown
onthedrawingsthroughautomaticwater
levelcontrollercompleteinallrespectand
asapprovedbytheEngineer/consultants.
SupplyandinstalltionofelectricalDBfor
airconditioningwithincomingand
outgoingcircuitbreakerswithAEG/
Hager/Terasaki/Fuji/BBincludingbusbar
volt&Amperemeters,selectorswitch
phaseindicatorlampscompleteinall
respectapprovedequivalentbythe
14
engineer/consultantoffollowingcapacity
Incoming1500ATPMCCB
Outgoing200ATPMCCB
Outgoing150ATPMCCB
Outgoing130ATPMCCB
Outgoing125ATPMCCB
Outgoing100ATPMCCB
Outgoing80ATPMCCB

Qty

Unit

No.

No.

No.

1
11
5
2
3
3
3

No.
No.
No.
No.
No.
No.
No.

Rate

Amount

Sr

Description

Supplyandinstallationofcopper
conductorpowercablesmakebyPakistan
Cables/AEGCables/NewAgecablesor
approvedequivalentcablesbythe
ConsultantincabletrayfromDBtoallout
doorunitsinstalledonroofasshownon
thedrawings,completeinallrespectas
15 andasapprovedbythe
Engineer/consultantasdetailedbelow:
3.5core300mmsq
3.5core35mmsq
3.5core30mmsq
3.5core18mmsq
3.5core16mmsq
3.5core10mmsq
3.5core8mmsq
Construct,fabricateandinstallFoundation
16 structureforframeforplacingcondensing
unitsinconsultationwithstructural
Engineeroftheclient.
SupplyofManufacture'sessentialspare
17 partsforallaboveitemsfor2yearsnormal
operationasapprovedbytheengineer/
Consultant(Providelist)
SupplyofDigitaltypeWallmounted
18
temperatureandhumidityindicator
Makewallopeningsinconcretewallsoflift
wellandprovided1''thickwoodenBoxin
19 theopeningsaspersizesgivenonthe
drawingscompleteinallrespectsasper
satisfactionofEngineer/Consultant
Testing,balancing&commissioningofthe
20 system.ReportofManufacture's
RepresentRequired)
Operationandmaintenanceofthesystem
21 (8:00)hratleastonemonthopeartionin
summerandonemonthinwinter

Qty

Unit

660
1270
1
1
65
1
1

Rft
Rft
Rft
Rft
Rft
Rft
Rft

17

No.

Lot

12

No.

Lot

Lot

Lot

Rate

Amount

Sr

Description

Aftercompletionofcommsissioning
prepareasbuilddrawingfortherecordof
22
theclientafterobtainingapprovalofthe
engineer/consultant
23 MDSSoftwareManagementController
Anyotheritemwhichisessentialto
completetheprojectandnotgiveninthis
24
BOQmaypleasebequotedandprovide
details.

Qty

Unit

Lot

Lot

Lot

Rate

Amount

TotalCostinRs
Note:a.EarnestmoneyshouldbeinformofPayOrder.
b.FollowingadvancepaymentscanbetakenagainstscheduledBankGurantee:
i.OnapprovaloftechnicalsubmittalsbytheConsultant/Engineer
ii.OnopeningLC
iii.Onproductionofbilloflanding
iv.Ondeliveryofequipmentatsiteagainsttheftinsurrance

10%
10%
10%
20%

You might also like