You are on page 1of 1

12

4-3 1/2" common nails into


new stud wall

2" x 12" SPF nailer plate secured with


4 - 1/4" Dia. x 5" long lag screws (2 each side)
penetrating into nailer plate, top
flange of I-joist, and top face of blocking material.

New 2" x 4" hoizontal brace at each I-joist.

Existing flat
roof joists

s
joist
roof
t
s
i
I-jo
eng
preg
n
i
t
Exis

Existing concrete
block exterior wall

Existing 2" x 6" wood frame exterior wall

SCALE: 1'

1'-0"

KNEE WALL DETAIL

1'-0"

WALL PLATE DETAIL


SCALE: 1"

1'-0"

12

12

6
3
A3.01

oof
ing r
slop
g
in
t
Exis

EQUAL

4
A3.01

Clear height determined


by truss design

65"
Existing flat roof

+15'
2 WALL PLATE

199 CARLSON DRIVE, NEWMARKET, ON L3Y 3H4

1" ACTUAL

0"
1 FIRST FLOOR

25'

15'-6"

BY REVISIONS DATE

0"
1 FIRST FLOOR

Date:

2016-03-24

Scale:

AS NOTED

Drawn:
Job:

SECTION A
SCALE: 3/16" =

Sheet

1'-0"

A3.01
Plotted On:

2016-03-24

2016-03-24

13'-6"

*** DATE OF ISSUE ***

Max. 59'
(18m)

IF THE ABOVE DIMENSION DOES NOT


MEASURE ONE INCH (1") EXACTLY, THIS
DRAWING HAS BEEN ENLARGED OR
REDUCED, AFFECTING ALL LABELED
DIMENSIONS.

EXISTING

D:\Projects1\707 Srigley\MasterTemplate NEW PROJECT FOLDER\Project PLN\PLN - BPN - BACKUPS\Srigley_2c.pln

+15'
2 WALL PLATE

BUILDING SECTIONS

SCALE: 3/4" =

EQUAL

Web Stifferener

Registered Design Firm: New Image Architectural Design


BCIN # 23165
Registered Designer:
Stan Mallory
BCIN # 29764
Signature/
Date:

Existing plate

TYPICAL

The following registered Design Firm and Registered Designer take


responsibility for the design of the herein described work.

Provide 1" rim joist material blocking


each side of pre-eng. I-joist web.
See Web Stiffener Detail.

New 2" x 6" @ 16" o.c. knee-wall

ROYAL CANADIAN LEGION

New dbl. 2" x 8" plate

PROPOSED NEW ROOF

4- 3 1/2" long common wired nails


toe-nailed c/w brace into nailer plate.
2 each side. Min. 20mm penetration
each nail.

12

707 SRIGLEY AVENUE


N E W M A R K E T , ONTARIO

New pre-eng wood roof trusses

This drawing, as an Instrument of Service, is provided by and is the


property of the Designer. The contractor shall check and verify and
accept responsibility for all dimensions and conditions on site and
shall notify the Designer of any errors, variations or discrepancies
from the supplied drawings and/or information. All drawings forming
a part of this drawing set shall be read together and not independantly.

Box 74, 130 Davis Drive, Suite 202, Newmarket, Ontario L3Y 3H4
V: 905-898-3514 Toll-free: 1-855-998-3514
F: 905-898-1998
adstruct@on.aibn.com
www.adengineering.com

1 -8 0 0 -3 6 3 -4 2 9 4

N E W IM A G E A R C H I T E C T U R A L D E S I G N
New pre-eng wood roof trusses