You are on page 1of 2

APPENDIKS

1. Menghitung nilai m-alkalinitas


a. Feed Water Boiler
Volume asam HCl
Volume sampel
M-alkalinitas

= 0,5 mL
= 10 mL
Volume asam HC l
=
x 1000
Volume sampel
0,5 m L
=
x 1000
10 m L
= 50 ppm

b. Boiler Water
Volume asam HCl
Volume sampel

= 5,8 mL
= 10 mL
Volume asam HC l
M-alkalinitas =
x 1000
Volume sampel
5,8 mL
=
x 1000
10 m L
=580 ppm

2. Menghitung nilai p-alkalinitas


a. Feed Water Boiler
Volume asam HCl
Volume sampel

= 0 mL
= 10 mL
Volume asam HC l
=
Volume sampel
0 mL
=
x 1000
10 m L
= 0 ppm

P-alkalinitas

b.

Boiler Water
Volume asam HCl
Volume sampel

= 5,3 mL
= 10 mL
Volume asam HC l
=
Volume sampel
5,3 m L
=
x 1000
10 m L
= 530 ppm

P-alkalinitas

3. Menghitung Total Hardness


Rumus Total Hardness :
Total Hardness :1,0009 1000

x 1000

x 1000

A
f
B

Dimana:
A = mL titran EDTA yang digunakan
B = mL sampel (sebelum diencerkan)
F = faktor perbedaan antara kadar larutan EDTA 0,01 M menurut standarisasi
dengan CaCO3 (f 1)
1,0009 = ekuivalensi antara 1 mL EDTA 0,01 M dan 1 mg kesadahan sebagai CaCO3

a. Feed Water Boiler


Volume asam HCl
Volume sampel
Total Hardness

b. Boiler Water
Volume asam HCl
Volume sampel
Total Hardness

= 1 mL
= 10 mL

A
xf
B
1 mL
= 1,0009 x 1000 x
10 m L
= 10,009 ppm
= 1,0009 x 1000 x

x 0,1

= 2,7 mL
= 10 mL

A
x 0,1
B
2,7 m L
= 1,0009 x 1000 x
10 m L
= 27,0243 ppm
= 1,0009 x 1000 x

x 0,1