You are on page 1of 2

ELECTRONIC STEP THERMOSTATS

Type DSE & FSE


GENERAL DESCRIPTION
Series SE electronic step thermostats are designed for
capacity control or other multistage control of cooling,
heating or airconditioning equipment.
Type SEK temperature sensing elements are available
for series SE.
Double constant voltage circuit and noise elimination
circuit assure stable control.
Model with heat-cool selector available.
Type DSE...2 Step thermostat
Type FSE...4 Step thermostat.
Type DSE

Type FSE

TYPE NUMBER SELECTION (SPECIFICATIONS)


Example for Complete Catalog No.:

DSE

1
020A
2
1
DSE1020A21
(Type Code) (Power Source Code) (Temp. Code) (Diff. Code) (Step. Temp. Code)

Catalog No.
Type

Power Source Code

DSE

See Note 1.

Temp. Code

Temp. Range (C)


Differential Code

Step Temp. Code

See Note 3.

See Note 4.

Min.

020A
040A
060A
020A
FSE

See Note 1.

040A

See Note 3.

Note 1: Power Source Code

Note 2: Temperature Code

Temp. Sensing
Element

Mode

20

20

SEK12

Cooling Mode

40

SEK14

HeatCool Selector

20

60

SEK16

Heating Mode

20

20

SEK12

Cooling Mode

40

SEK14

HeatCool Selector

20

60

SEK16

Heating Mode

See Note 4.

060A

Max.

Note 3: Differential Code

Note 4: Step Temp. Code

Code

Power Source

Code

Range (C)

Code

Differential (C)

Code

100V. AC

020A

20 to 20

0.5

0.5

200V. AC

040A

0 to 40

1.0

1.0

110V. AC

060A

20 to 60

1.5

1.5

220V. AC

2.0

2.0

24V. AC

2.5

2.5

240V. AC

3.0

3.0

230V. AC
and Others

3.5

4.0

Step Temp. (C)

When ordering, please specify complete catalog No. comprising type, power source, temperature, differential and step temp. codes.

TEMPERATURE SENSING ELEMENT SELECTION


Basic models of sensing element required for each temperature range are
as specified in the table of TYPE NUMBER SELECTION.
Depending on the application, various styles of element are available.
Please specify model number from the table below when ordering.
Type

Application
Air or water Temperature Control

SEK12H, 14H, 16H

SEK..P

Air Temperature Control

SEK14P, 16P

SEK..R001

Room Temperature Control

SEK12R001, 14R001, 16R001

SEK..A

Liquid Immersion Application

SEK12A001, 14A001, 16A001

SEK..K

Duct Temperature Control

SEK14K001, 16K001

SEK..H with drip-proof construction

47

Models available

SEK..H

Wt
(kg)

0.58

0.89

OPERATION
Type DSE
2 Step
U L2
Terminal
1 Step
U L1

Cooling Mode

Heating Mode

D
On
Off

2 Step
On
U L2H2
Off
Terminal

S
D

1 Step
U L1H1

On
Off

Terminal

Terminal
Set Point

S
D

On
Off
Set Point

Temp.

Temp.

Type FSE
Cooling Mode

Heating Mode
D

4 Step
C4 L4
Terminal

Off

Terminal

S
D

3 Step
C3 L3

On

Terminal

Off

4 Step
C4 L4H4 On

On

Off
S

3 Step
C3 L3H3 On
Terminal

Off

D
2 Step
C2 L2

On

Terminal

Off

Terminal

S
D

1 Step
C1 L1

On

Terminal

Off

2 Step
C2 L2H2 On

Off
S

1 Step
C1 L1H1 On
Terminal
Set Point

Off
Set Point

Temp.

Temp.

WIRING DIAGRAM
Type DSE

Type FSE
Power Supply

Sensor

T1

T2

L1

H1

L2

H2

Load
1 Step

Sensor

1 Step

2 Step

Load

Load

T1 T2 L1 C1 H1 L2 C2 H2

Load

2 Step

L3 C3 H3 L4 C4 H4

Power Supply

Cooling Mode: Arrow marks indicate directions of switch action


on temperature increase.
Heating Mode: Arrow marks indicate directions of switch action
on temperature decrease.

Load

Load

3 Step

4 Step

Power Supply for Load

Terminal locations of L* and H* on type DSE060A and FSE060A


are changed place each other.

DIMENSIONS
Type DSE

Type FSE

Temp.
Adjusting
Knob

Temp.
Adjusting
Knob

Heat-Cool Selector
(Only Temp. Code 040A)

64
74

15

69

5.6

5.6

60
110

60
110

Heat-Cool Selector
(Only Temp. Code 040A)

110
120

15

69

Unit: mm

48