You are on page 1of 12

Coiled Tubes

Material Specification HS-90TM


HS-90 CMTM
(Continuously milled tubing)

HS-90 WTM
(Butt welded tube sections)

PHYSICAL PROPERTIES

Minimum yield strength 90,000 psi


Minimum tensile strength 97,000 psi
Minimum Elongation 25%
Maximum Hardness 22C Rockwell

CHEMICAL COMPOSITION - %

Carbon 0.10 0.15 range


Manganese 0660 0.90 range
Phosphorus 0.25 max
Sulfur 0.005 max
Silicon 0.25 0.40 range
Chromium 0.55 0.70 range
Copper 0.40 0.40 max
Aluminum 0.040 max
Nickel 0.14 0.30 range
Molybdenum 0.10 0.15 range

STEEL ALLOY DESCRIPTION

CONTACT INFO
Tenaris Coiled Tubes
8615 E. Sam Houston Pkwy N.
77044 Houston Texas USA
coiledtubesales@tenaris.com
(1) 281 458 2883 tel
(1) 281 458 2886 fax

A-606 type 4 molly

HS-90 GRADE*
DIMENSIONS
(Inches)

NOMINAL
WEIGHT
Lbs. / ft.

O.D.
SPECIFIED

O.D.
(mm)

WALL
SPECIFIED

WALL
(mm)

WALL
MINIMUM

I.D.
CALCULATED

1.000

25.4

1.250

31.8

1.500

38.1

1.750

44.5

2.000

50.8

2.375

60.3

0.095
0.102
0.109
0.095
0.102
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.095
0.102
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.125
0.134
0.145
0.156
0.175
0.190
0.204

2.41
2.59
2.77
2.41
2.59
2.77
2.95
3.18
3.40
3.68
3.96
4.45
2.41
2.59
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
5.18
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
5.18
3.18
3.40
3.68
3.96
4.45
4.83
5.18

0.090
0.097
0.104
0.090
0.097
0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.090
0.097
0.104
0.111
0.118
0.128
0.138
0.148
0.167
0.180
0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.195
0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.195
0.120
0.128
0.138
0.148
0.167
0.180
0.195

0.810
0.796
0.782
1.060
1.046
1.032
1.018
1.000
0.982
0.960
0.938
0.900
1.310
1.296
1.282
1.268
1.250
1.232
1.210
1.188
1.150
1.120
1.532
1.518
1.500
1.482
1.460
1.438
1.400
1.370
1.342
1.782
1.768
1.750
1.732
1.710
1.688
1.650
1.620
1.592
2.125
2.107
2.085
2.063
2.025
1.995
1.967

0.920
0.981
1.040
1.175
1.254
1.332
1.408
1.506
1.601
1.715
1.827
2.014
1.429
1.527
1.623
1.719
1.840
1.960
2.104
2.245
2.483
2.665
1.915
2.029
2.175
2.318
2.492
2.662
2.951
3.173
3.377
2.207
2.340
2.509
2.677
2.880
3.080
3.419
3.682
3.923
3.011
3.215
3.462
3.706
4.122
4.445
4.742

TUBE LOAD BODY


(Lbs.)

INTERNAL
PRESSURE (psi)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. Ibs.)

INTERNAL
CAPACITY
per 1000 ft.

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

W/ MIN.
WALL

INTERNAL
MIN

YIELD

ULTIMATE

GALLONS

BARRELS

24,300
25,900
27,500
31,000
33,100
35,200
37,200
39,800
42,300
45,300
48,300
53,200
37,700
40,300
42,900
45,400
48,600
51,800
55,600
59,300
65,600
70,400
50,600
53,600
57,400
61,200
65,800
70,300
77,900
83,800
89,200
58,300
61,800
66,300
70,700
76,100
81,300
90,300
97,200
103,600
79,500
84,900
91,400
97,900
108,900
1 17,400
125,200

26,200
27,900
29,600
33,400
35,700
37,900
40,100
42,900
45,600
48,800
52,000
57,300
40,700
43,500
46,200
48,900
52,400
55,800
59,900
63,900
70,700
75,800
54,500
57,800
61,900
66,000
70,900
75,800
84,000
90,300
96,100
62,800
66,600
71,400
76,200
82,000
87,700
97,300
104,800
111,600
85,700
91,500
98,500
105,500
117,300
126,500
135,000

14,300
15,300
16,400
11,500
12,400
13,200
14,100
15,200
16,100
17,400
18,500
20,700
9,600
10,400
11,100
11,800
12,500
13,600
14,600
15,600
18,700
20,100
9,500
10,200
11,000
11,700
12,600
13,500
15,100
16,200
17,500
8,400
8,900
9,600
10,300
11,000
11,800
13,300
14,300
15,400
8,100
8,700
9,300
10,000
11,200
12,100
13,100

15,900
17,000
18,200
12,800
13,800
14,700
15,700
16,600
17,900
19,300
20,600
23,000
10,700
11,500
12,300
13,100
14,200
15,100
16,200
17,300
19,400
20,800
10,600
11,300
12,200
13,000
14,000
14,900
16,800
18,000
19,400
9,300
9,900
10,700
1 1,400
12,300
13,100
14,800
15,900
17,100
9,000
9,600
10,400
11,100
12,500
13,400
14,500

0.257
0.275
0.293
0.328
0.351
0.374
0.397
0.420
0.451
0.482
0.512
0.568
0.399
0.428
0.456
0.484
0.512
0.552
0.590
0.629
0.699
0.746
0.538
0.572
0.605
0.652
0.699
0.745
0.831
0.888
0.953
0.619
0.659
0.709
0.753
0.807
0.861
0.962
1.029
1.106
0.850
0.904
0.970
1.035
1.158
1.241
1.335

0.528
0.510
0.493
0.899
0.876
0.853
0.830
0.808
0.776
0.745
0.715
0.659
1.368
1.340
1.311
1.283
1.255
1.215
1.177
1.139
1.068
1.021
1.867
1.834
1.800
1.753
1.706
1.660
1.575
1.517
1.453
2.522
2.483
2.443
2.389
2.334
2.280
2.180
2.112
2.036
3.580
3.527
3.460
3.395
3.272
3.189
3.095

466
491
515
769
814
858
900
941
996
1,048
1,097
1,181
1,148
1,220
1,289
1,357
1,422
1,511
1,596
1,677
1,821
1,911
1,809
1,907
2,030
2,135
2,262
2,384
2,602
2,741
2,893
2,416
2,552
2,721
2,867
3,045
3,216
3,525
3,724
3,943
3,950
4,170
4,438
4,699
5,175
5,485
5,829

508
540
570
825
879
931
982
,032
,100
,166
,229
,342
,218
,300
,380
,459
,536
,643
,746
,846
2,028
2,145
1,918
2,030
2,171
2,294
2,444
2,589
2,855
3,029
3,222
2,544
2,696
2,887
3,054
3,258
3,458
3,825
4,066
4,335
4,152
4,398
4,700
4,997
5,545
5,908
6,316

26.77
25.85
24.95
45.84
44.64
43.45
42.28
40.80
39.34
37.60
35.90
33.05
70.02
68.53
67.06
65.60
63.75
61.93
59.74
57.58
53.96
51.18
95.76
94.02
91.80
89.61
86.97
84.37
79.97
76.58
73.48
129.56
127.53
124.95
122.39
119.30
116.25
111.08
107.08
103.41
184.24
181.13
177.37
173.64
167.31
162.38
157.86

0.64
0.62
0.59
1.09
1.06
1.03
1.01
0.97
0.94
0.90
0.85
0.79
1.67
1.63
1.60
1.56
1.52
1.47
1.42
1.37
1.28
1.22
2.28
2.24
2.19
2.13
2.07
2.01
1.90
1.82
1.75
3.08
3.04
2.97
2.91
2.84
2.77
2.64
2.55
2.46
4.39
4.31
4.22
4.13
3.98
3.87
3.76

*Selected coiled tubing data


(90 Kpsi Min. Yield Strength; 97 Kpsi Min. Tensile Strength; 25 % Min. Elongation; Loads calculated using nom. wall)

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS
40.80
40.80
40.80
63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75
91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80
124.95
124.95
124.95
124.95
124.95
124.95
124.95
124.95
124.95
163.20
163.20
163.20
163.20
163.20
163.20
163.20
163.20
163.20
230.14
230.14
230.14
230.14
230.14
230.14
230.14

BARRELS
1.000
1.000
1.000
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.97
2.97
2.97
2.97
2.97
2.97
2.97
2.97
2.97
3.89
3.89
3.89
3.89
3.89
3.89
3.89
3.89
3.89
5.48
5.48
5.48
5.48
5.48
5.48
5.48

Test pressure value equals 90% of internal yield pressure rating. Maximum working pressure is a function of tube condition and is determined by
user. All data is for new tubing at minimum strength. * Available as continuously milled tubing (CM) or conventional butt-welded tubing
sections (W). See individual size sheets for additional wall thicknesses. 2-5/8", 2-7/8", and other sizes not shown are also available.

HS-90 GRADE* METRIC VALUES


DIMENSIONS
(mm)

NOMINAL
WEIGHT
Kg/m

O.D.
SPECIFIED

O.D.
(inches)

WALL
SPECIFIED

WALL
(inches)

WALL
MINIMUM

I.D.
CALCULATED

25.4

1.000

31.8

1.250

38.1

1.500

44.5

1.750

50.8

2.000

60.3

2.375

2.41
2.59
2.77
2.21
2.41
2.59
2.77
2.95
3.18
3.40
3.68
3.96
4.45
2.41
2.59
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
5.18
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
5.18
3.18
3.40
3.68
3.96
4.45
4.83
5.18

0.095
0.102
0.109
0.087
0.095
0.102
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.095
0.102
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.125
0.134
0.145
0.156
0.175
0.190
0.204

2.29
2.46
2.64
2.11
2.29
2.46
2.64
2.82
3.00
3.25
3.51
3.76
4.24
2.29
2.46
2.64
2.82
3.00
3.25
3.51
3.76
4.24
4.57
2.64
2.82
3.00
3.25
3.51
3.76
4.24
4.57
4.95
2.64
2.82
3.00
3.25
3.51
3.76
4.24
4.57
4.95
3.00
3.25
3.51
3.76
4.24
4.57
4.95

20.6
20.2
19.9
27.3
26.9
26.6
26.2
25.9
25.4
24.9
24.4
23.8
22.9
33.3
32.9
32.6
32.2
31.8
31.3
30.7
30.2
29.2
28.4
38.9
38.6
38.1
37.6
37.1
36.5
35.6
34.8
34.1
45.3
44.9
44.5
44.0
43.4
42.9
41.9
41.1
40.4
54.0
53.5
53.0
52.4
51.4
50.7
50.0

1.37
1.46
1.55
1.61
1.75
1.86
1.98
2.09
2.24
2.38
2.55
2.72
2.99
2.12
2.27
2.41
2.55
2.73
2.91
3.13
3.34
3.69
3.96
2.85
3.02
3.23
3.45
3.70
3.96
4.39
4.72
5.02
3.28
3.48
3.73
3.98
4.28
4.58
5.08
5.47
5.83
4.47
4.78
5.14
5.51
6.13
6.61
7.05

TUBE LOAD BODY


(Newtons)

INTERNAL
PRESSURE (kPa)

TUBING AREA
(sq. cm)

TORSIONAL
YIELD
(N-m)

INTERNAL
CAPACITY

EXTERNAL
DISPLACEMENT

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

W/ MIN.
WALL

INTERNAL
MIN

YIELD

ULTIMATE

LITERS / METER

LITERS / METER

96,100
102,300
108,500
113,000
122,800
130,800
139,200
147,200
157,000
167,200
179,300
190,800
210,400
149,000
159,200
169,500
179,300
192,200
204,600
219,700
234,400
259,300
278,400
200,200
211,700
227,300
242,000
260,200
278,000
308,200
331,400
352,700
230,400
244,200
262,000
279,300
300,700
321,600
357,200
384,300
409,700
314,500
335,800
361,600
387,000
430,600
463,900
495,100

105,900
112,500
119,200
124,500
134,800
144,100
153,000
161,900
173,000
183,700
197,000
209,900
231,300
164,100
175,300
186,400
197,500
211,300
225,100
241,500
258,000
285,100
306,000
220,200
233,100
250,000
266,400
286,000
305,600
338,900
364,300
387,900
253,500
268,700
288,200
307,400
330,900
353,600
392,800
423,000
450,600
346,100
369,200
397,700
425,700
473,300
510,600
544,400

87,600
93,800
100,700
65,500
70,300
75,800
81,400
86,200
91,700
99,300
106,200
113,800
120,700
59,300
63,400
68,300
72,400
77,200
83,400
89,600
95,800
106,900
115,100
58,600
62,100
66,200
71,700
77,200
82,700
92,400
99,300
106,900
51,000
54,500
57,900
62,700
67,600
72,400
81,400
87,600
94,500
49,000
53,100
57,200
61,400
69,000
74,500
80,000

97,200
104,800
111,700
72,400
78,600
84,100
90,300
95,800
102,000
110,300
117,900
126,200
140,700
65,500
70,300
75,800
80,700
85,500
92,400
99,300
106,200
119,300
127,600
64,800
69,000
73,800
79,300
85,500
91,700
102,700
110,300
119,300
57,200
60,700
64,800
69,600
75,200
80,700
90,300
97,200
104,800
54,500
59,300
63,400
68,300
76,500
82,700
88,900

1.66
1.78
1.89
1.96
2.12
2.27
2.42
2.56
2.71
2.91
3.11
3.31
3.67
2.57
2.76
2.94
3.12
3.31
3.56
3.81
4.06
4.51
4.82
3.47
3.69
3.90
4.21
4.51
4.81
5.36
5.73
6.15
4.00
4.25
4.50
4.86
5.21
5.56
6.20
6.64
7.13
5.40
5.83
6.26
6.68
7.47
8.01
8.62

3.41
3.29
3.18
5.95
5.80
5.65
5.50
5.35
5.21
5.01
4.81
4.61
4.25
8.83
8.64
8.46
8.28
8.10
7.84
7.59
7.35
6.89
6.59
12.05
11.83
11.61
11.31
11.01
10.71
10.16
9.79
9.37
16.27
16.02
15.77
15.41
15.06
14.71
14.06
13.63
13.13
23.18
22.75
22.32
21.90
21.11
20.57
19.97

560
590
620
870
930
980
1,030
1,090
1,130
1,200
1,260
1,320
1,420
1,380
1,470
1,550
1,640
1,710
1,820
1,920
2,020
2,190
2,300
2,180
2,300
2,410
2,570
2,730
2,870
3,140
3,300
3,490
2,910
3,080
3,240
3,460
3,670
3,880
4,250
4,490
4,750
4,690
5,030
5,350
5,660
6,240
6,610
7,030

610
650
690
930
990
1,060
1,120
1,180
1,240
1,330
1,410
1,480
1,620
1,470
1,570
1,660
1,760
1,850
1,980
2,100
2,230
2,440
2,590
2,310
2,450
2,580
2,760
2,950
3,120
3,440
3,650
3,880
3,070
3,250
3,430
3,680
3,930
4,170
4,610
4,900
5,230
4,930
5,300
5,670
6,020
6,680
7,120
7,610

0.33
0.32
0.31
0.59
0.57
0.55
0.54
0.53
0.51
0.49
0.47
0.45
0.41
0.87
0.85
0.83
0.81
0.79
0.77
0.74
0.72
0.67
0.64
1.19
1.17
1.14
1.11
1.08
1.05
0.99
0.95
0.91
1.61
1.58
1.55
1.52
1.48
1.44
1.38
1.33
1.28
2.29
2.25
2.20
2.16
2.08
2.02
1.96

0.51
0.51
0.51
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.55
1.55
1.55
1.55
1.55
1.55
1.55
1.55
1.55
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.86
2.86
2.86
2.86
2.86
2.86
2.86

*Selected coiled tubing data


(621 N/mm2 Min. Yield Strength; 669 N/mm2 Min. Tensile Strength; 25 % Min. Elongation; Loads calculated using nom. wall

Test pressure value equals 90% of internal yield pressure rating. Maximum working pressure is a function of tube condition and is determined by
user. All data is for new tubing at minimum strength. * Available as continuously milled tubing (CM) or conventional butt-welded tubing
sections (W). 66.7mm and 73.0mm, and other sizes not shown are also available.

Coiled Tubing Data 1" O.D.


HS-90 CM* or HS-90 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

l.000

0.095
0.102
0.109

0.090
0.097
0.104

0.810
0.796
0.782

TUBE BODY LOAD


(Lbs.)

NOMINAL
WEIGHT
(lbs / ft)

0.920
0.981
1.040

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

24,300
25,900
27,500

26,200
27,900
29,600

14,300
15,300
16,400

15,900
17,000
18,200

HS-90 CM* or HS-90 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

INTERNAL
CAPACITY
per 1000 ft.

TORSIONAL
YIELD
(ft. / Lbs.)

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

l.000

0.090
0.097
0.104

0.257
0.275
0.293

0.528
0.510
0.493

466
491
515

508
540
570

26.77
25.85
24.95

0.64
0.62
0.59

GALLONS

40.80
40.80
40.80

BARRELS

0.97
0.97
0.97

* Continuously milled tubing.


** Butt-welded tube sections.

HS-90 CM or HS-90 W

www.tenaris.com
January 2007. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 1.25" O.D.


HS-90 CM* or HS-90 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

l.250

0.095
0.102
0.109
0.116
0.125
0134
0.145
0.156
0.175

0.090
0.097
0.104
0.111
0.120
0.128
0.138
0.148
0.167

1.060
1.046
1.032
1.018
1.000
0.982
0.960
0.938
0.900

NOMINAL
WEIGHT
(lbs / ft)

1.175
1.254
1.332
1.408
1.506
1.601
1.715
1.827
2.014

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

31,000
33,100
35,200
37,200
39,800
42,300
45,300
48,300
53,200

33,400
35,700
37,900
40,100
42,900
45,600
48,800
52,000
57,300

11,500
12,400
13,200
14,100
15,200
16,200
17,300
18,500
20,700

12,800
13,800
14,700
15,700
16,900
17,900
19,300
20,600
23,000

HS-90 CM* or HS-90 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

l.250

0.090
0.097
0.104
0.111
0.120
0.128
0.138
0.148
0.167

0.324
0.351
0.374
0.397
0.420
0.451
0.482
0.512
0.568

0.899
0.876
0.853
0.830
0.808
0.776
0.745
0.715
0.659

769
814
858
900
952
996
1,048
1,097
1,181

825
879
931
982
1,046
1,100
1,166
1,229
1,342

45.84
44.64
43.45
42.28
40.80
39.34
37.60
35.90
33.05

1.09
1.06
1.03
1.01
0.97
.094
.090
0.85
0.79

GALLONS

63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75

BARRELS

1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52

* Continuously milled tubing.


** Butt-welded tube sections.

HS-90 CM or HS-90 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 1.50" O.D.


HS-90 CM* or HS-90 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

1.500

0.095
0.102
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190

0.090
0.097
0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.167

1.310
1.296
1.282
1.268
1.250
1.232
1.210
1.188
1.150
1.120

NOMINAL
WEIGHT
(lbs / ft)

1.459
1.527
1.623
1.719
1.840
1.960
2.104
2.245
2.483
2.665

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

37,700
40,300
42,900
45,400
48,600
51,800
55,600
59,300
65,600
70,400

40,700
43,500
46,200
48,900
52,400
55,800
59,900
63,900
70,700
75,800

9,600
10,400
11,100
11,800
12,800
13,600
14,600
15,600
17,500
18,700

10,700
11,500
12,300
13,100
14,200
15,100
16,200
17,300
19,400
20,800

HS-90 CM* or HS-90 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

1.500

0.090
0.097
0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180

0.399
0.428
0.456
0.484
0.512
0.552
0.590
0.629
0.699
0.746

1.368
1.340
1.311
1.283
1.255
1.215
1.177
1.139
1.068
1.021

1,148
1,220
1,289
1,357
1,440
1,511
1,596
1,677
1,821
1,911

1,218
1,300
1,380
1,459
1,557
1,643
1,746
1,846
2,028
2,145

70.02
68053
67.06
65.60
63.75
61.93
59.74
57.58
53.96
51.18

1.67
1.63
1.60
1.56
1.52
1.47
1.42
1.37
1.28
1.22

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS

91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80

BARRELS

2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19

* Continuously milled tubing.


** Butt-welded tube sections.

HS-90 CM or HS-90 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 1.75" O.D.


HS-90 CM* or HS-90 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

1.500

0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204

0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.195

1.532
1.518
1.500
1.482
1.460
1.438
1.400
1.370
1.342

NOMINAL
WEIGHT
(lbs / ft)

1.915
2.029
2.175
2.318
2.492
2.662
2.951
3.173
3.377

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

50,600
53,600
57,400
61,200
65,800
70,300
77,900
83,800
89,200

54,500
57,800
61,900
66,000
70,900
75,800
84,000
90,300
96,100

9,500
10,200
11,000
11,700
12,600
13,500
15,100
16,200
17,500

10,600
11,300
12,200
13,000
14,000
14,900
16,800
18,000
19,400

HS-90 CM* or HS-90 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

1.500

0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.195

0.538
0.572
0.605
0.652
0.699
0.745
0.831
0.888
0.953

1.867
1.834
1.800
1.753
1.706
1.660
1.575
1.517
1.453

1,809
1,907
2,003
2,135
2,262
2,384
2,602
2,741
2,893

1,918
2,030
2,140
2,294
2,444
2,589
2,855
3,029
3,222

95.76
94.02
91.80
89.61
86.97
84.37
79.97
76.58
73.48

2.28
2.24
2.19
2.13
2.07
2.01
1.90
1.82
1.75

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS

124.95
124.95
124.95
124.95
124.95
124.95
124.95
124.95
124.95

BARRELS

2.97
2.97
2.97
2.97
2.97
2.97
2.97
2.97
2.97

* Continuously milled tubing.


** Butt-welded tube sections.

HS-90 CM or HS-90 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 2.00" O.D.


HS-90 CM* or HS-90 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

2.000

0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204

0.104
0.111
0.118
0.128
0.138
0.148
0.167
0.180
0.195

1.782
1.768
1.750
1.732
1.710
1.688
1.650
1.620
1.592

NOMINAL
WEIGHT
(lbs / ft)

2.207
2.340
2.509
2.677
2.880
3.080
3.419
3.682
3.923

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

58,300
61,800
66,300
70,700
76,100
81,300
90,300
97,200
103,600

62,800
66,600
71,400
76,200
82,000
87,700
97,300
104,800
111,600

8,400
8,900
9,500
10,300
11,000
11,800
13,300
14,300
15,400

9,300
9,900
10,500
11,400
12,300
13,100
14,800
15,900
17,100

HS-90 CM* or HS-90 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

2.000

0.104
0.111
0.118
0.128
0.138
0.148
0.167
0.180
0.195

0.619
0.659
0.698
0.753
0.807
0.861
0.962
1.029
1.106

2.522
2.483
2.444
2.389
2.334
2.280
2.180
2.112
2.036

2,416
2,552
2,684
2,867
3,045
3,216
3,525
3,724
3,943

2,544
2,696
2,845
3,054
3,258
3,458
3,825
4,066
4,335

129.56
127.53
124.95
122.39
119.30
116.25
111.08
107.08
103.41

3.08
3.04
2.97
2.91
2.84
2.77
2.64
2.55
2.46

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS

163.20
163.20
163.20
163.20
163.20
163.20
163.20
163.20
163.20

BARRELS

3.89
3.89
3.89
3.89
3.89
3.89
3.89
3.89
3.89

* Continuously milled tubing.


** Butt-welded tube sections.

HS-90 CM or HS-90 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 2.375" O.D.


HS-90 CM* or HS-90 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

2.375

0.125
0.134
0.145
0.156
0.175
0.190
0.204

0.118
0.128
0.138
0.148
0.167
0.180
0.195

2.125
2.107
2.085
2.063
2.025
1.995
1.967

NOMINAL
WEIGHT
(lbs / ft)

3.011
3.215
3.462
3.706
4.122
4.445
4.742

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

79500
84900
91400
97900
108900
117400
125200

85700
91500
98500
105500
117300
126500
135000

8000
8700
9300
10000
11200
12100
13100

8900
9600
10400
11100
12500
13400
14500

HS-90 CM* or HS-90 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

2.375

0.118
0.128
0.138
0.148
0.167
0.180
0.195

0.837
0.904
0.970
1.035
1.158
1.241
1.335

3.593
3.527
3.460
3.395
3.272
3.189
3.095

3894
4170
4438
4699
5175
5485
5829

4090
4398
4700
4997
5545
5908
6316

184.24
181.13
177.37
173.64
167.31
162.38
157.86

4.39
4.31
4.22
4.13
3.98
3.87
3.76

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS

230.14
230.14
230.14
230.14
230.14
230.14
230.14

BARRELS

5.48
5.48
5.48
5.48
5.48
5.48
5.48

* Continuously milled tubing.


** Butt-welded tube sections.

HS-90 CM or HS-90 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 2.625" O.D.


HS-90 CM* or HS-90 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

2.625

0.156
0.175
0.190
0.204

0.148
0.167
0.180
0.195

2.313
2.275
2.245
2.217

NOMINAL
WEIGHT
(lbs / ft)

4.124
4.590
4.953
5.288

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

108,900
121,200
130,800
139,600

117,400
130,700
141,000
150,500

9,100
10,200
11,000
11,900

10100
11300
12200
13200

HS-90 CM* or HS-90 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

2.625

0.148
0.167
0.180
0.195

1.152
1.290
1.383
1.489

4.260
4.122
4.029
3.923

5,845
6,452
6,850
7,292

6,180
6,869
7,328
7,844

218.28
211.17
205.63
200.54

5.20
5.03
4.90
4.77

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS

281.14
281.14
281.14
281.14

BARRELS

6.69
6.69
6.69
6.69

* Continuously milled tubing.


** Butt-welded tube sections.

HS-90 CM or HS-90 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 2.875" O.D.


HS-90 CM* or HS-90 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

2.875

0.156
0.175
0.190
0.204

0.148
0.167
0.180
0.195

2.563
2.525
2.495
2.467

NOMINAL
WEIGHT
(lbs / ft)

4.541
5.059
5.462
5.834

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

119,900
133,600
144,200
154,100

129,300
144,000
155,500
166,000

8,300
9,300
10,000
10,900

9,200
10,400
11,200
12,100

HS-90 CM* or HS-90 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

2.875

0.148
0.167
0.180
0.195

1.268
1.421
1.524
1.642

5.224
5.071
4.968
4.850

7,117
7,871
8,368
8,922

7,489
8,335
8,900
9,537

268.01
260.12
253.98
248.31

6.38
6.19
6.05
5.91

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS

337.24
337.24
337.24
337.24

BARRELS

8.03
8.03
8.03
8.03

* Continuously milled tubing.


** Butt-welded tube sections.

HS-90 CM or HS-90 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new tubing at specified minimum
strengths.

Coiled Tubing Data 3.5" O.D.


HS-90 CM* or HS-90 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

3.500

0.175
0.190
0.204

0.167
0.180
0.195

3.150
3.120
3.092

NOMINAL
WEIGHT
(lbs / ft)

6.230
6.733
7.199

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

164,500
177,800
190,100

177,300
191,600
204,900

7,700
8,300
9,000

8,500
9,200
9,900

HS-90 CM* or HS-90 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

3.500

0.167
0.180
0.195

1.749
1.877
2.025

7.872
7.744
7.596

12,039
12,831
13,720

12,621
13,500
14,496

404.84
397.16
390.07

9.64
9.46
9.26

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS

499.80
499.80
499.80

BARRELS

11.90
11.90
11.90

* Continuously milled tubing.


** Butt-welded tube sections.

HS-90 CM or HS-90 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

You might also like