You are on page 1of 4

Dear Karthik , We are sending parameters to you according that please Quote send back all the details

of list of equipments,instruments,pipeings if any relatans . Test Results Sl.no Tests 1 Colour(Hazan Units) 2 pH 3 EC(micro Siemens/cm) dddddddddd 4 Dissolved solids ,mg/l 5 Total Suspended Solids,mg/l 6 Total Hardness as CaCo3,mg/l 7 Total Alkalinity as CaCo3 mg/l 8 Non carbonate Hardness as CaCo3 mg/l 9 Calcium as Ca, mg/l 10 Magnesium as Mg, mg/l 11 Sodium as Na, mg/l 12 Potasium as K, mg/l 13 Chloride as Cl, mg/l 14 Sulphate as SO4, mg/l 15 Silica as SiO2 ,mg/l 16 Iron as Fe ,mg/l 17 Nitrate as No3, mg/l 18 Fluoride as F, mg/l 19 COD, mg/l 20 BOD for 3days at27 0 C, mg/l 21 Oil & Grease, mg/l Interpretation of results : Nil Devation from test method and condition : Nil Method of test IS:3025 P- 4 IS:3025-P-11 APHA-21st Edn IS:3025-P-16 APHA-21st Edn IS:3025-P-21 IS:3025-P-23 ----IS:3025-P-40 IS:3025-P-46 IS:3025-P-45 APHA-21st Edn IS:3025-P-32 IS:3025-P-24 APHA-21st Edn IS:3025-P-53 APHA-21st Edn APHA-21st Edn IS:3025(P-44) APHA-21st Edn IS:3025-P-39 Results Dark pink coloured 7.51 5000 3250 76 1650 355 1295 426 142 396 3 1280 337 14 0.10 5 1.10 6500 2500 3

DESIGN SPECIFICATIONS CAPACITY Type of Evaporator Feed Rate Initial TDS Product from EVAPORATOR Final TDS (Concentration) Total Evaporation : : : : : : : 30 KLD Triple Effect Forced Circulation System 1500 Kg/hr 3250 ppm (0.32% w/w) 20 kg/hr 300000 ppm (30% w/w) 1480 Kg/Hr

Chemical Composition

Form Solvent Specific Gravity Inlet Temperature Mode of Heating Steam

SOLUTION PROPERTIES : Ca: 426 ppm; Mg: 142 ppm; Na: 426 ppm; Cl: 1280 ppm; SO4: 337 ppm; COD: 6500 ppm; Oil & Grease must be NIL. : Clear Solution with totally dissolved solids : Water : 1.01 : 30 C : : Dry Saturated Steam 5 kg/ cm2 (g) at the inlet of Calendria -1 UTILITIES

Power : Voltage : 415 / 4 wire Frequency : 50 HZ Connected Load : Consumed Load : Steam Pressure : Dry Saturated at 5 kg/cm2 bar(g) Quantity of Steam in Kg/Hr : Cooling water : Raw Water at 2 kgs./sq.cm(g) : Inlet temp 33C /Outlet temp. 39C

30 KW 25.5 KW 475 kg /hr 40 m3 /hr.

SCOPE OF SUPPLY FABRICATED EQUIPMENT Description Quantity Feed Tank (FT-01) Evaporator Heat Exchangers (Calandria) 1 no. 3 nos.

Sr. No. 1 2

Material of Construction SS 304 Shell : SS 304; Tubes : SS 316; Tube Sheet : SS 316 38.1 OD X 1.4mm thk X 6m Height Shell : SS 304 ; Tubes : SS 316; Tube Sheet : SS 316 25.4 OD X 1.4mm Thk X 6m Height SS 316 SS 304 SS 304

Tube Size 3 Feed Preheaters 3 nos.

Tube Size 4 5 6 Vapor Liquid Separators Flash Tank FLT-01 Surface Condenser (Shell & Tube) 3 nos. 1 no. 1 no. 1 no. 3 nos. 1 no. 1 no. 1 lot 1 lot

Section B Standard Bought out Components for Evaporator


Feed Pump (Centrifugal) Recirculation Pumps (Axial Flow) Product Pump Condensate Pump Piping Fitting & Valves (Contact Parts) Vapor Ducting SS 316 SS 316 SS 316 SS 304 SS 316 SS 304

Details of Instrument Control Panel: 1. 2. 3. 4. 5. 6. Pressure gauges on discharge of all the pumps. Temperature control loop for Jacket Temperature of 1st calandria. Temperature Indicators for feed inlet, Preheater Outlets & Product Outlets. Temperature Indicators for vapors & Liquids on all vapor separators. Vacuum / Pressure gauge on all the vapor separator & shell of calendria. Feed and Condensate Rota meter.

Total evaporation system package fabricated equipment, Manufactured by us as per scope of supply specified above: Rs. 30,00,000/Bought out components for system as per scope of supply specified above: Rs. 9,00,000/MCC Panel, Instrumentation, & electrical Cables: Supply price for Structure along with fabrication (20 Tons): Rs. 5,00,000/Rs. 13,00,000/-

You might also like