You are on page 1of 33

8DK 02 05 04 01 00 PCZZA ED 00

ALCATEL-LUCENT INDONESIA

Evolution A9100 BTS Installation Standard

ABSTRACT This document describes the installation standard for indoor and outdoor part of A9100 BTS product

Domain Process Owner Type Originator Distrib. Codes

: : : : :

ALCATEL-LUCENT INDONESIA IMPLEMENTATION INSTRUCTIONS, USER GUIDE DURMAWEL SAHARA Internal: Y/N External: Y/N

APPROVALS
ALU - QA XL QA XL - RND

1/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

TABLE OF CONTENTS 1 1.1 1.2 INSTALLATION INDOOR ........................................................................4 Indoor Tray (Top View).........................................................................4 GROUNDING SYSTEM ............................................................................6

1.1.1 Indoor Tray (Front View) ......................................................................5 1.2.1 Arrangement of Wiring Copper rod ..........................................................6 1.2.2 Connection Copper rod to Main Grounding Bar (MGB) ...................................7 1.2.3 Connection Grounding at BTS Radio, Transmission and Rectifier to MGB ...........8 1.3 FEEDER ENTRY ...................................................................................9 floor of shelter (Inside view) ..................................................................9 1.3.2 Installation Feeder Entry (height of feeder entry and dimension from base ........ floor of shelter (Inside view) ................................................................ 10 1.3.3 Arrangement of Feeder Entry and Connection Grounding Arrester to Busbar ... 11 1.4 BTS INDOOR ..................................................................................... 12 1.4.1 Connection Wiring Cable at the top BTS Radio.......................................... 12 1.4.2 Connection Wiring Board at BTS Radio Rack ............................................ 13 1.4.4 Connection Wiring Alarm and Traffic Cables at DDF External Alternative 1 ...... 14 1.4.5 Connection Wiring Alarm and Traffic Cables at DDF External Alternative 2 ...... 15 1.4.6 BTS Radio Installation (Side View) ......................................................... 16 1.5 POWER SUPPLY (RECTIFIER) ................................................................. 17 1.5.1 Connection Wiring Power Cable at Power Suply (Rectifier) .......................... 17 2 2.1 INSTALLATION OUTDOOR..................................................................... 18 Installation Position Feeder Coaxial at Vertical Tray of Tower and Installation .... Feeder Clamp .................................................................................. 18 2.1.1 Installation Grounding Kit (at the top and bottom) .................................... 19 2.1.2 Installation Grounding Kit at Feeder Entry (Outdoor) ................................. 20 2.1.3 Installation Labelling, Wiring Jumper Cable and Grounding at Antenna........... 21 3 3.1 3.2 3.3 3.4 3.5
APPROVALS
ALU - QA XL QA XL - RND

1.3.1 Installation Feeder Entry (height of feeder entry and dimension from base ........

INSTALLATION ANTENNA TYPE APM 40.................................................... 22 Installation Antenna and Mounting Hardware Part 1................................... 22 Installation Antenna and Mounting Hardware Part 2................................... 23 Installation Antenna and Mounting Hardware Part 3................................... 24 Installation Antenna and Mounting Hardware Part 4................................... 25 Installation Antenna and Mounting Hardware Part 5................................... 26
2/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

4 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9

GENERAL MATERIALS .......................................................................... 27 Feeder Entry.................................................................................... 27 Heat Shrinkable Sleeve (Condom).......................................................... 27 Cable Ties (Tie Wrap) Type CS-300X ...................................................... 28 Cable Ties (Tie Wrap) Type CS-390L ...................................................... 28 Cable Ties (Tie Wrap) Type CS-200L ...................................................... 29 Cable Ties (Tie Wrap) Type CS-150T ...................................................... 29 Labelling......................................................................................... 30 Connector ....................................................................................... 30 HHD Cavity Anchor ........................................................................... 31

4.10 Cable Shoe 1x35 ............................................................................... 31 4.11 Protection Edge ................................................................................ 31 4.12 Clamp Copper rod (SIMEL CH 10.70)....................................................... 32 4.13 Clamp Copper rod (SIMEL BB 50-80) ....................................................... 32 APPENDIX ................................................................................................ 33 DOCUMENT MANAGEMENT............................................................................ 33

APPROVALS
ALU - QA XL QA XL - RND

3/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

1
1.1

INSTALLATION INDOOR
Indoor Tray (Top View)

2000

ACPDB

Air Inlet Under AC 2

Alarm Above AC 2

AC 1
Bracket Tray

Bracket Tray

PWR SUPPLY AC BELL TYPE CSM 20

70 150 70 150

Clamp (@0.5m) Copper Rod

Copper Rod

Hole for Cable Pwr Supply Edge Rubber Protection

2500

Tech room/Shelter Height of Ceiling : 3.00 Height of Tray : 2.40


"A"
Holes for Cable Wiring and Edge Rubber Protection

RACK TRANS & DDF

70 150

Hole for Cable Pwr Supply Edge Rubber Protection

Bracket Tray

Bracket Tray

70 150

BTS EVO 900 MHz

600

550

FEEDER ENTRY

"A"

150

H : 2000

AC 1

Bracket Tray

MGB

Bracket Tray

560

880

560
MW

500
FEEDER ENTRY
SPARE NA PA QA

Bracket Tray

1 6
SPARE

2 7
SPARE

3 8
NB

4 9
PB

5 10
QB

FEEDER ENTRY
INSIDE VIEW (from Inside of Shelter)

Cable Tray Support Tray HHD Molly Anchor

Shelter Wall

Notes : "A" (See BTS Installtion Side View on Page 16)

1. MW 2. Spare 3. Antenna Sector 1A (NA) 4. Antenna Sector 2A (PA) 5. Antenna Sector 3A (QA) 6. Spare 7. Spare 8. Antenna Sector 1B (NB) 9. Antenna sector 2B (PB) 10.Antenna Sector 3B (QB)

SECTION A
Scale : NTS

APPROVALS
ALU - QA XL QA XL - RND

4/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

1.1.1 Indoor Tray (Front View)

tT

ra

DC Fan

1 6
B ra c k e t T ra y

2 7

3 8

4 9

5
10

ra

ck

C a b le T ra y

B ra c k e t T ra y B ra c k e t T ra y

`
B u s b a r fo r G r o u n d A rr e s te r

G roun d C a b le B C 3 5

AC

C op per R od

B ra c k e t T ra y

C op per R od B ra c k e t T ra y B ra c k e t T ra y

FAP
C la m p ( @ 1 m ) G r o u n d c a b le B c 35

B TS E v o liu m

M a in G r o u n d B a r (M G B )

R e c tifie r

ck

IN S ID E T E C H N IC A L R O O M

APPROVALS
ALU - QA XL QA XL - RND

5/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

1.2

GROUNDING SYSTEM

1.2.1 Arrangement of Wiring Copper rod

ACPDB

Air Inlet Under AC 2

Alarm Above AC 2

AC 1
Bracket Tray

Bracket Tray

Clamp (@0.5m) Copper Rod

Copper Rod

Bracket Tray

Bracket Tray

Tech room/Shelter Height of Ceiling : 3.00 Height of Tray : 2.40

Bracket Tray

H : 2000

AC 1

Bracket Tray

MGB

Bracket Tray

Cable Tray Support Tray


HHD Molly Anchor

Shelter Wall

SECTION A
Scale : NTS

APPROVALS
ALU - QA XL QA XL - RND

6/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

1.2.2

Connection Copper rod to Main Grounding Bar (MGB)

D C Fa n

`
B us bar

"A "

AC

Copper Rod Clamp simel CH Copper Rod Copper Rod

Busbar Cable Tray Cable Grounding

to Main Grounding Bar

DETAIL A
Scale : NTS G rou nd C a b le B C 3 5 C o ppe r Rod

to Copper Rod

to Busbar

Cable Grounding Cable Shoe SS Bolt M8

Cable Grounding Cable Shoe SS Bolt M8

"B "
M a in G r o u n d . B a r

M a in G ro u n d . B a r

DETAIL B
Scale : NTS

Copper Rod Clamp simel CH Copper Rod Cable Tray Bracket Tray HHD Molly Anchor

Busbar Cable Shoe Cable Tray Bracket Tray HHD Molly Anchor

HHD Molly Anchor

Copper Rod

Ground Cable BC 35

SIDE VIEW
Scale : NTS

SIDE VIEW
Scale : NTS

Cable Shoe SS Bolt M8 Main Grounding Bar (MGB)

Cable Shoe SS Bolt M8 Main Grounding Bar (MGB)

APPROVALS
ALU - QA XL QA XL - RND

7/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

1.2.3

Connection Grounding at BTS Radio, Transmission and Rectifier to MGB

tT

ra

D C Fan

1 6
B ra c k e t T ra y

2 7

3 8

4 9

5
10

ra

ck

C a b le T ra y

B ra c k e t T ra y B ra c k e t T ra y

`
B u s b a r fo r G r o u n d A rr e s te r

G roun d C a b le B C 3 5

AC

C op per R od

B ra c k e t T ra y

C op per R od B ra c k e t T ra y B ra c k e t T ra y

FAP
C la m p ( @ 1 m ) G r o u n d c a b le Y /G B C 3 5

B TS E v o liu m

M a in G r o u n d B a r (M G B )

R e c tifie r

ac

IN S ID E T E C H N IC A L R O O M

Copper Rod Clamp simel CH Cable Tray


Cable Grounding BC35

Copper Rod Clamp simel CH Cable Tray


Cable Grounding BC35

Copper Rod Clamp simel CH Cable Tray


Cable Grounding BC35

Bracket Tray

Bracket Tray

Bracket Tray

IDU Rack 19"

R e c tifie r

BTS E v o liu m

R a d io T r a n s m is s i o n

SIDE VIEW
Scale: NTS

NOTES : This is Temporary Standard, The New Standard is on going validation by ALU & XL
APPROVALS
ALU - QA XL QA XL - RND

8/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

1.3

FEEDER ENTRY

1.3.1 Installation Feeder Entry (height of hole feeder entry and dimension from base floor of shelter (Inside View)

500

1 6

2 7

3 8

4 9

5 10

Distribution Module

1 1 2 5 3 4 5 6 7 8 9 10 20 11 12 13 25 14

10

15

Hariff

2400

15 16 30 17 18 19 20

35

40

MW RACK 19"

21 22 23 24

45

25 26 27

50

28 29 30

POWER SUPPLY

55 31 32 33 60 34 35 36 37 38 70 39 40 41 75 42 43 44 80 45

65

HOLES

2500

INSIDE VIEW
520

Notes :
PA QA

MW

Spare

NA

1
280

2 7
Spare

3 8
NB

4 9
PB

5 10
QB

6
Spare

INSIDE VIEW (From The Inside Technical Room/Shelter)

FFEDER ENTRY

1. MW 2. Spare 3. Antenna Sector 1A (NA) 4. Antenna Sector 2A (PA) 5. Antenna Sector 3A (QA) 6. Spare 7. Spare 8. Antena Sector 1B (NB) 9. Antenna Sector 2B (PB) 10. Antenna Sector 3B (QB)

APPROVALS
ALU - QA XL QA XL - RND

UNITS

2700

3000
9/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

1.3.2 Installation Feeder Entry (height of hole feeder entry and dimension from base floor of shelter (Inside View Isometric)

50 0

FE

ED

ER

EN

TR

D C F an

1 6

2 7

3 8

4 9

5
10

B u sb a r

Copper Rod

Copper bar

Grounding Cable Y/G 1x35

520

MW

Spare

NA

PA

QA

2700

1
280

2 7
Spare

3 8
NB

4 9
PB

5 10
QB

6
Spare

INSIDE VIEW (From The Inside Technical Room/Shelter)

FFEDER ENTRY

Notes :
B u sb a r

1. MW 2. Spare 3. Antenna Sector 1A (NA) 4. Antenna Sector 2A (PA) 5. Antenna Sector 3A (QA) 6. Spare 7. Spare 8. Antenna Sector 1B (NB) 9. Antenna Sector 2B (PB) 10. Antenna Sector 3B (QB)

INSIDE VIEW ISOMETRIC


Scale ~ NTS

APPROVALS
ALU - QA XL QA XL - RND

10/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

1.3.3 Arrangement of Feeder Entry and Connection Grounding Arrester to Busbar

C o n n e c to r 1 / 2 " - 7 / 1 6 m a le

L ig h tn in g A r r e ste r C la m p F e e d e r T y p e D o u b le C o n n e c to r 7 / 8 " - 7 / 1 6 fe m a le C o a x ia l F e e d e r 7 / 8 " (6 fe e d e r) Label B ra c k e t L Label C a b le J u m p e r 1 / 2 " to B T S R a d io

C a b le E n try

PA NA

QA NA QB PB PA

QA

NB

NA

PA

QA

G r o u n d in g B u sb a r

70 0

C op per rod G r o u n d in g C a b le A r r e st e r

C o p p e r b a r in sta lle d d ir e c tly to M a in G r o u n d B a r (M G B )

C a b le g r o u n d B C 3 5 in sta lle d d ir e c tly to M a in G ro u n d B a r (M G B )

APPROVALS
ALU - QA XL QA XL - RND

11/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

1.4

BTS INDOOR

1.4.1 Connection Wiring Cable at the top BTS Radio


EDGE RUBBER PROTECTION CABLE TRAY HOLES FOR CABLE WIRING

COPPER ROD

Ground Cable Y/G BC 35

JUMPER CABLE

JUMPER CABLE

JUMPER CABLE
JUMPER CABLE

PA

NB

NA

QB

LABEL

QA

METAL SHIELD CONNECT TO BTS

PB

-48V

0V

ALARM CABLE GREY

Cable Power (Blue Color) Cable Power (Blue Color) Cable Traffic (Grey Color)

EDGE RUBBER PROTECTION METAL SHIELD


Cable Black (Black) Cable Power (Blue)
Power Cable (black)

Cable Abis (Grey) Cable Alarm (Grey)

CABLE TRAY

DETAIL WARING CABLE ALARAM, PCM, POWER & GROUNDING

NOTES : This is Temporary Standard, The New Standard is on going validation by ALU & XL
APPROVALS
ALU - QA XL QA XL - RND

12/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

1.4.2 Connection Wiring Cables at BTS Radio Rack

P ANT A P ANT B Q ANT A

N ANT A N ANT B Q ANT B

TO P C O NNEC TO R BTS
Abis 4 XBCB XRT XGPS Abis 3 Abis 2 Abis 1

- 48 V
Abis 4 Abis 3 Abis 2 Abis 1

0V

XGND GND

4 ABIS RELAYS
XCLK2 XCLK1 XCLK1 IN / OUT IN OUT

BTS INT

ALARMS INPUTS/OUTPUTS

S R 1

S R 2

S R 3

S R 4

S R 5

G S O 0 4 C AB L E fro m A N C G to T o p C on n. BT S

FANU
Q AN T A
TXAIN1 ANT A RX0AOUT1

FANU

FANU
P ANT A
TXAIN1 ANT A RX0AOUT1

RX1AOUT1 TXAIN2

RX1AOUT1 TXAIN2

RX0AOUT2 RX1AOUT2 RX0BOUT2 RX1BOUT2

TXAOUT

RX0AOUT2 RX1AOUT2 RX0BOUT2

TXAOUT

TXBIN2

RX1BOUT2

TXBIN2

RX0BOUT1 RX1BOUT1 ON OM ALARM TXBIN1 ON

RX0BOUT1 RX1BOUT1 TXBIN1

OM ALARM

TXBOUT

TXBOUT

ANT B

ANT B

Q AN T B

G S O 0 3 C AB L E fro m T R E to A N C G
TX TX

P ANT B

S e c t or 3

S e c t or 2
POWER ENABLE

R X C A BL E
from T R E to A N C G
POWER ENABLE OFF TEST OFF TEST

RX0

RX0

RX1 RSL OP PWR TX BCCH FAULT Y

RX1

T RE 1

RSL OP PWR

TX BCCH FAULT Y

T RE 1

A B IS C A B LE fro m S U M A to A bis P ort

FANU
A B I S 1/2
B T S C O N N E C T O N A R E A

FANU
S UM A

FANU
N ANT A
TXAIN1 ANT A RX0AOUT1

RX1AOUT1 TXAIN2

B T S T E R M I N A L

M N E M O

S E R I A L

RX0AOUT2 RX1AOUT2 RX0BOUT2 RX1BOUT2

TXAOUT

TXBIN2

T E S T

RX0BOUT1 RX1BOUT1
AB IS 1

TXBIN1

O M L O & M O M U P S 1

ON OM ALARM

AB IS 2

T RAN S F AU LT

TXBOUT

PS2

ANT B

N ANT B

TX

S e c t or 1
POWER ENABLE

OFF TEST

RX0

RX1 RSL OP PWR TX BCCH FAULT Y

T RE 1

FANU

FANU

FANU

APPROVALS
ALU - QA XL QA XL - RND

13/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

1.4.3 Connection Wiring Alarm and Traffic Cables at DDF External Alternative 1

CABLE TRAY INDOOR

Alarm cable Abis cable

Copper rod
Grounding Cable

1 1 2 5 3 4 5 10 6 7
P1 P2 3 4 5 P6
TX Channel 1-6 ALU

DDF ALU

10

11

12

13 P14 15
RX Channel 1-6 ALU

16 17

15
Alarm 1 ALU Alarm 2 ALU

8 9 10 11 12 13 14 15

DDF Additional

20

IDU IDU RADIO RACK 19"

25

30

16 17

APPROVALS
ALU - QA XL QA XL - RND

14/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

1.4.4 Connection Wiring Alarm and Traffic Cables at DDF External Alternative 2

CABLE TRAY INDOOR

Alarm cable Abis cable

Copper rod
Grounding Cable

1 1 2 5 3 4 5 10
Alarm ALU

6 7

DDF ALU

P1

P6
TX Channel 1-6 ALU

10

11

12

13 P14 15
RX Channel 1-6 ALU

16 17

15 8 9 10 11 12 13 14 15 30 16 17

Alarm ALU

DDF Additional

20

IDU IDU RADIO RACK 19"

25

APPROVALS
ALU - QA XL QA XL - RND

15/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

1.4.5 BTS Radio Installation (Side View)

"A"
HHD Molly Anchor

Shelter Wall

1800

BTS EVO

ISOMETRIK VIEW
Scale : NTS

450 32 2

32

Scale ~ 1:15

SIDE VIEW
Shelter Wall

25

HHD Molly Anchor Rail Z Support

DETAIL RAIL Z SUPPORT


Scale : NTS

25

BTS EVO

Scale : NTS

DETAIL A

32

APPROVALS
ALU - QA XL QA XL - RND

16/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

1.5

INSTALLATION OUTDOOR

1.5.1 Connection Wiring Power Cable at Power supply (Rectifier)

EDGE RUBBER PROTECTION

COPPER ROD CABLE TRAY

CABLE GROUNDING

CABLE POWER BLACK CABLE POWER BLUE

To BTS

POWER CABLE

COPPER BAR TERMINAL GROUNDING RECTIFIER

Power Cable Cable Pin Lug Black Cable Blue Cable

"A"
ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB

MCB 50A
ABB

NC 50 N ON
NC 50 N NC 50 N ON C50 ON C50 NC 50 N NC 50 N NC 50 N NC 50 N NC 50 N NC 50 N NC 50 N NC 50 N ON C50 ON C50 ON C50 ON C50 ON C50 ON C50 ON C50 ON C50

C50

MCB 50A

MCB 50A

MCB 50A

MCB 50A

MCB 50A

MCB 50A

MCB 50A

MCB 50A

MCB 50A

MCB 50A

MCB 50A

DETAIL A

APPROVALS
ALU - QA XL QA XL - RND

17/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

2
2.1

INSTALLATION OUTDOOR
Installation Position Feeder Coaxial at Vertical Tray of Tower and Installation Feeder Clamp
To Antenna Sector 2A (PA) To Antenna Sector 1B (NB) To Antenna Sector 1A (NA) To Antenna Sector 2B (PB). To Antenna Sector 3A (QA). To Antenna Sector 3B (QB).

COAXIAL FEEDER 7/8"

LADDER TRAY

GROUNDING KITS

TIE WRAP

TIE WRAP

BUSBAR

ISOLATOR

FEEDER CLAMP FOR 7/8" Every 0.8 ~ 1.0 meter

APPROVALS
ALU - QA XL QA XL - RND

18/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

2.1.1 Installation Grounding Kit (at the top and bottom)

L i g h t n i n g P r o t e c t i o n

70.00m
A NTE NN A S UPPO R T (B A C K T O b A CK T O T O W ER M G B IS O L A T O R IS O L A T O R

G R O U N D IN G K IT (B A C K T O B A CK )

G R O U N D IN G T O A N T E N N A S EC T O R (B A C K T O B A CK )

B U SB A R 1

D E T A IL
BU S BA R T R AY

BUSBAR 1

T O T O W ER M G B

IS O L A T O R

G R O U N D IN G K IT (B A C K T O B A CK )

SP A R E

SP A R E

IS O L A T O R

D E T A IL

D E T A IL B U S B A R A T V E R T IC A L T R A Y
T R AY

BUSBAR 2
BU S BA R

D E T A IL B U S B A R 3 A T H O R IZ O N T A L T R A Y
BUS BAR 2

BUS BAR 3

APPROVALS
ALU - QA XL QA XL - RND

19/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

2.1.2 Installation Grounding Kit at Feeder Entry (Outdoor)

To To To To To To

Antenna Sector Antenna Sector Antenna Sector Antenna Sector Antenna Sector Antenna Sector

3B (QB) 3A (QA) 2B (NB) 2A (PA) 1B (NB) 1A (NA)

Coaxial Feeder Feedery Entry Heat Shrinkable (Condom) Grounding Kits Label
QA PA QB PB NB NA

Vertical Tray Cable Ground Kits Grounding Kits

Cover Feeder Holes


Busbar

Busbar

Coaxial Feeder 7/8" Horizontal Tray CableGround

30 c m

Feeder Hole

CABLE TIES (Tie Wrap) CABLE TIES

Heat Shringkable Sleeve(Condom)

Wall

NA NB 10 c m
HORIZONTAL TRAY Isolator Busbar GROUNDING KITS SS Bolt M8 Cable Shoe

DETAIL BUSBAR AT HORIZONTAL TRAY & GROUNDING KIT

APPROVALS
ALU - QA XL QA XL - RND

20/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

2.1.3 Installation Labelling, Wiring Jumper Cable and Grounding at Antenna

QB NA

NB PA

LABE L T IE W R A P F EE D ER C AB LE

LABE L

T IE W R A P F EE D E R C AB LE

T IE W R A P G R O U N D IN G C A B L E
BUSBAR

NB PB QB NA PA QA

T IE W R A P G R O U N D IN G C A B L E LABE L

TRAY

BUSBAR
To TO WER M GB IS O L A TO R IS O L A TO R

TRAY

G R O U N D IN G K IT A N T E N N A S E C T O R (B A C K T O B A C K ) (B A C K T O B A C K )

D E T A IL B U S B A R A T V E R T IC A L T R A Y

BUSBAR

NOTES : This is Temporary Standard, The New Standard is on going validation by ALU & XL
APPROVALS
ALU - QA XL QA XL - RND

21/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

3
3.1

INSTALLATION ANTENNA TYPE APM40


Installation Antenna and Mounting Hardware Part 1

APPROVALS
ALU - QA XL QA XL - RND

22/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

3.2

Installation Antenna and Mounting Hardware Part 2

APPROVALS
ALU - QA XL QA XL - RND

23/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

3.3

Installation Antenna and Mounting Hardware Part 3

APPROVALS
ALU - QA XL QA XL - RND

24/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

3.4

Installation Antenna and Mounting Hardware Part 4

APPROVALS
ALU - QA XL QA XL - RND

25/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

3.5

Installation Antenna and Mounting Hardware Part 5

APPROVALS
ALU - QA XL QA XL - RND

26/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

4
4.1

GENERAL MATERIALS
Feeder Entry :

Material from Steel grade ST 41 Dimension : 280 x 3 x 520

4.2

Heat Shrinkable Sleeve (Condom) :

Material from Rubber Raychem Code : 75/22 ER 3310

APPROVALS
ALU - QA XL QA XL - RND

27/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

4.3

Cable Ties (Tie Wrap) Type CS-300X :

Code Material SIGMA TIES CS 300X Dimension : 7.6 x 270 Function : Installation Outdoor (at Top Antenna)

4.4

Cable Ties (Tie wrap) Type CS-390L :

Code Material SIGMA TIES CS 390L Dimension : 4.8 x 270 Function : Installation Indoor (at Jumper Cable)

APPROVALS
ALU - QA XL QA XL - RND

28/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

4.5

Cable Ties (Tie wrap) CS 200L :

Code Material SIGMA TIES CS 200L Dimension : 3.6 x 180 Function : Installation Indoor (at Alarm & PCM Cable)

4.6

Cable Ties (Tie wrap) CS 150 T :

Code Material SIGMA TIES CS 150L Dimension : 3.6 x 140 Function : Installation Indoor (for Connection cable at top BTS radio)

APPROVALS
ALU - QA XL QA XL - RND

29/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

4.7

Labelling :

Labelling, material from Acrilique Function : Label Identification

4.8

Connector :

Heat shrinkable sleeve

1/2 DIN Male

O-Ring CONNECTOR 7/8 RFS

7/8 DIN Female

APPROVALS
ALU - QA XL QA XL - RND

30/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

4.9

HHD Cavity Anchor :

4.10

Cable Shoe :

HHD CAVITY ANCHOR Specification Screw 5x45mm (Hilti) Function : Fixation for equipment, accessories and bracket cable tray at Gypsum wall.

Cable Shoe 1x35mm

4.11

Protection Edge :

PROTECTION EDGE Specification from Rubber L2000mm

APPROVALS
ALU - QA XL QA XL - RND

31/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

4.12 Clamp Copper rod (SIMEL CH 10.70) :

4.13

Clamp Copper rod (SIMEL BB 50- 80) :

APPROVALS
ALU - QA XL QA XL - RND

32/33

EFFECTIVE DATE : 10 SEPTEMBER 2007

8DK 02 05 04 01 00 PCZZA ED 00

APPENDIX
NA

RELEVANT DOCUMENTS AND WEB SITES


# [1] [2] Title of the document/web site Mounting HW APM40, Radio Frequency Systems Evolution A9100 BTS Installation Manual Reference/Web link http://www.rfsworld.com/
3BK 17226 0001 RJZZA Ed.09

ABBREVIATIONS AND ACRONYMS


Wording ALU Definition Alcatel-Lucent

DOCUMENT MANAGEMENT
Location of the reference of this document (electronic copy): ISO9000\3.Work Instruction

HISTORY
Short description of significant changes to previous edition: Edition Originated Effective Date Originator Date 00 15 Aug 07 01 Sept 07 Durmawel Sahara

Change Description

First Release

END OF DOCUMENT

APPROVALS
ALU - QA XL QA XL - RND

33/33

EFFECTIVE DATE : 10 SEPTEMBER 2007