You are on page 1of 3

ENMAS ANDRITZ PRIVATE LIMITED

ITC-PSPD 400 TDS/D NEW REC. BOILER

CUSTOMER

M/s. ITC LIMITED-PSPD, UNIT: BHADRACHALAM, ANDHRA PRADESH NEW RECOVERY BOILER - 400TDS/D TECHNICAL SPECIFICATIONS FOR AMT AGITATOR

PROJECT SUBJECT

: :

1.

INTRODUCTION

Ash mixing tank agitator specified below is required for operation in chemical recovery boiler.
2. SCOPE OF SUPPLIES

i.

Complete agitator with supports, Geared motor, Coupling etc., as per the enclosed specification.

3.

SPECIFIC ASPECTS

i.

SITE CONDITIONS: a.) Mill site is situated 60 m above the MSL and temperature varies +20 to 51 OC. b.) Seismic area classification equals to zone III as per IS 1893 c.) Power supply: 415 V +10 %, 3 Phase 50 Hz + 3 %. Geared motor drive power to be selected with adequate margin over the power absorbed. Please quote for spares for 2 years operation with item wise price.

ii.

iii.
4.

DATA / DOCUMENTS TO BE FURNISHED ( X )


ALONGWITH ORDER 3 SETS X -X ---

Sl. No.

DETAILS OF DOCUMENTS

OFFER 3 SETS X X X ---

SUPPLY 6 SETS -X -X X

1. 2. 3. 4. 5. 6.

DETAIL PERFORMANCE DATA DETAIL DIMENSIONAL DATA / CATALOGUES ARRANGEMENT DRAWINGS MATERIAL TEST CERTIFICATE PERFORMANCE TEST, GUARANTEE CERTIFICATE INSTALLATION, OPERATION & MAINTENANCE MANUAL

--

--

Prepared Checked Approved

Name SMR SMR NAP

Date 05.01.10 05.01.10 05.01.10

Job Code : Doc No. : Rev No. : Rev Date Name Description

BB 290 M J/BB290M/SPECN/15 0

Sheet 1 of 3

H:\PENGG H\BOILER\PROJECT\ITC BOOSTER BOILER\B.O.C\INDENTED\AGITATOR\agitator_amt specn.doc

ENMAS ANDRITZ PRIVATE LIMITED

ITC-PSPD 400 TDS/D NEW REC. BOILER

5.

TECHNICAL DATA

TAG NUMBER DESCRIPTION

542-T-005

AMT AGITATOR ASSEMBLY To mix ESP ash with Black liquor Black liquor 1.4 10-11 Cp Deg C m 250 105 15 (Approx)

Application Fluid Specific gravity pH Viscosity Temperature Tank capacity Tank size Dia Height Baffles Type of agitator Material of construction Shaft Impeller Rotation speed Blade dia Shaft length Motor Power Motor Speed Dimensions of tank Specific requirement Painting Quantity No. rpm mm mm kW rpm mm mm

2770 2800 2 nos. Supplier to specify

AISI 304 AISI 304 Supplier to specify Supplier to specify Supplier to specify Supplier to specify 1500 / 1450 Attached Propeller blades to be removable inside the tank. Agitator to have bottom guide arrangement. For Carbon steel parts like drive support etc. 1 (One)

Prepared Checked Approved

Name SMR SMR NAP

Date 05.01.10 05.01.10 05.01.10

Job Code : Doc No. : Rev No. : Rev Date Name Description

BB 290 M J/BB290M/SPECN/15 0

Sheet 2 of 3

H:\PENGG H\BOILER\PROJECT\ITC BOOSTER BOILER\B.O.C\INDENTED\AGITATOR\agitator_amt specn.doc

ENMAS ANDRITZ PRIVATE LIMITED

ITC-PSPD 400 TDS/D NEW REC. BOILER

ESP ash characteristics a) Bulk density - 80 to 100 kg/m3 b) Particle size 5micron to 100 micron c) Ash flow - 4.2 T/hr (approx) d) Ash composition Na2SO4 NaCl Na2CO3 - 75% -15% - 10%
- 55

Black liquor flow to AMT

m3/hr

Prepared Checked Approved

Name SMR SMR NAP

Date 05.01.10 05.01.10 05.01.10

Job Code : Doc No. : Rev No. : Rev Date Name Description

BB 290 M J/BB290M/SPECN/15 0

Sheet 3 of 3

H:\PENGG H\BOILER\PROJECT\ITC BOOSTER BOILER\B.O.C\INDENTED\AGITATOR\agitator_amt specn.doc

You might also like