Pump Technical Data Sheet for Misc. Horizontal Pumps Sl No.

Description ACW Booster Pump

1.00 1.01

GENERAL Designation ACW Booster Pump

1.02 1.03

Type of Pump Service

Horizontal centrifugal Clarified Water

1.04 1.05 1.06 1.07 2.00 2.01 2.02 2.03 2.04 2.05

Pump Duty Pumps to be designed for parallel operation Pump Manufacturer Model / Size TECHNICAL PARAMETERS Performance standard Nos. of Pumps required Nos. of Pumps working Nos. of Pumps standby Liquid handled

Continuous Yes WPIL LIMITED WP MF 200/320

HIS Eighteen (18) Twelve (12) Six (6) Clarified Water

2.06 2.07 2.08

Design Liquid Temperature Suction Lift or Suction Head Rated Flow in M3/Hr

35C Flooded suction 550

P-HG-50211-28-DS

Rev 01

Sl No.

Description

ACW Booster Pump

2.09 2.10 2.11

Pump Total Dynamic Head, MWC Losses in Pump in MWC Pump Shut-off head in MWC (Prefer upto 140% of pump operating head) Range of operation of the pump Rated speed in rpm NPSHR in MWC (at suction flange inlet) Nos. of Stages Pump overall efficiency at Duty point in % Rotation viewed from coupling end Suction specific speed POWER CONSUMPTION

13 NIL 21

2.12 2.13 2.14 2.15 2.16 2.17 2.18 3.00

_30 % to __125 % of rated capacity 1474 3.8 1 80.00 % CW 10493

3.01 3.02

Guaranteed pump shaft input power at rated condition, KW Maximum pump input power at shut-off head Motor kW rating DESIGN AND CONSTRUCTION FEATURES Max. Impeller Diameter in mm Suction nozzle size and rating

24.35 22

3.03 4.00 4.01 4.02

30

340 MM 250 mm

P-HG-50211-28-DS

Rev 01

Sl No.

Description

ACW Booster Pump

4.03 4.04 4 13 4.14 5.00 5.01 5.02 5.03 5.04 5.05 6.00 6.01 6.02

Discharge nozzle size and rating Type of Pump casing Shaft sealing arrangement sealing liquid Near Field Noise Level MATERIALOFCONSTRUCTION Casing Impeller Shaft Shaft sleeve Base Plate INSPECTION AND TESTING Material Test Hydrostatic test pressure (bar)(1.5 times SOH Duration of test in minutes Vibration PERFORMANCE TEST Performance Testing standard NPSH R test Dynamic balancing test

200 mm BACK PULL OUT Gland packing 85dBA

2 % Ni-Cl to IS 210 FG 260 Stainless steel ASTM -A-351-CF8M. Stainless steel, SS 410 316 Stainless steel MS FAB.

6 15 min HIS

6.03 6.04 7.00 7.01 7.02 7.03

HIS NO Yes

P-HG-50211-28-DS

Rev 01

Sl No.

Description

ACW Booster Pump

8.00 8.01

DRIVE MOTOR Type

Induction Motor 415 V, 3 Phase, 50 HZ, TEFC

8.02 9.00 9.01 9.02

RPM WEIGHT DATA Approximate weight of the pump in Kg Approximate weight of the motor in Kg

1474

290 kg 365 kg

P-HG-50211-28-DS

Rev 01

Pump Technical Data Sheet for Misc. Horizontal Pumps Sl No. Description Boiler Fill Pump

1.00 1.01

GENERAL Designation Boiler Fill Pump

1.02 1.03

Type of Pump Service

Horizontal centrifugal DM water (Chemical dosed for PH correction)

1.04 1.05 1.06 1.07 2.00 2.01 2.02 2.03 2.04 2.05

Pump Duty Pumps to be designed for parallel operation Pump Manufacturer Model / Size TECHNICAL PARAMETERS Performance standard Nos. of Pumps required Nos. of Pumps working Nos. of Pumps standby Liquid handled

Intermittent Yes WPIL LIMITED WP 65/320

HIS Three (3) Two (2) One (1) DM water(Chemical dosed for PH correction)

2.06 2.07 2.08

Design Liquid Temperature Suction Lift or Suction Head Rated Flow in M3/Hr

35C Flooded suction 100

P-HG-50191-93-DS

Rev 01

Sl No.

Description

Boiler Fill Pump

2.09 2.10 2.11

Pump Total Dynamic Head, MWC Losses in Pump in MWC Pump Shut-off head in MWC (Prefer upto 140% of pump operating head) Range of operation of the pump Rated speed in rpm NPSHR in MWC (at suction flange inlet) Nos. of Stages Pump overall efficiency at Duty point in % Rotation viewed from coupling end Suction specific speed POWER CONSUMPTION

101 NIL 120

2.12 2.13 2.14 2.15 2.16 2.17 2.18 3.00

_30 % to __125 % of ratedd capacity 2960 4 1 64.00% CW 8827.03

3.01 3.02

Guaranteed pump shaft input power at rated condition, KW Maximum pump input power at shut-off head Motor kW rating DESIGN AND CONSTRUCTION FEATURES Max. Impeller Diameter in mm Suction nozzle size and rating

42.98 23

3.03 4.00 4.01 4.02

55

329 MM 100 mm

P-HG-50191-93-DS

Rev 01

Sl No.

Description

Boiler Fill Pump

4.03 4.04 4 13 4.14 5.00 5.01 5.02 5.03 5.04 5.05 6.00 6.01 6.02 6.03 6.04 7.00 7.01 7.02 7.03

Discharge nozzle size and rating Type of Pump casing Shaft sealing arrangement sealing liquid Near Field Noise Level MATERIALOFCONSTRUCTION Casing Impeller Shaft Shaft sleeve Base Plate INSPECTION AND TESTING Material Test Hydrostatic test pressure (bar)(1.5 times SOH Duration of test in minutes Vibration PERFORMANCE TEST Performance Testing standard NPSH R test Dynamic balancing test

65 mm BACK PULL OUT Gland packing 85dBA

SS ASTM - A-351-CF8M. Stainless steel ASTM -A-351-CF8M. Stainless steel, SS 410 316 Stainless steel MS FAB.

18 15 min HIS

HIS NO Yes

P-HG-50191-93-DS

Rev 01

Sl No.

Description

Boiler Fill Pump

8.00 8.01

DRIVE MOTOR Type

Induction Motor 415 V, 3 Phase, 50 HZ, TEFC

8.02 9.00 9.01 9.02

RPM WEIGHT DATA Approximate weight of the pump in Kg Approximate weight of the motor in Kg

2960

170 kg 515 kg

P-HG-50191-93-DS

Rev 01

Pump Technical Data Sheet for Misc. Horizontal Pumps Sl No. Description CT Make up Pumps

1.00 1.01

GENERAL Designation CT Make up Pumps

1.02 1.03

Type of Pump Service

Horizontal centrifugal Clarified Water

1.04 1.05 1.06 1.07 2.00 2.01 2.02 2.03 2.04 2.05

Pump Duty Pumps to be designed for parallel operation Pump Manufacturer Model / Size TECHNICAL PARAMETERS Performance standard Nos. of Pumps required Nos. of Pumps working Nos. of Pumps standby Liquid handled

Continuous Yes WPIL LIMITED 14MN16A

HIS Three (3) Two (2) One (1) Clarified Water

2.06 2.07 2.08

Design Liquid Temperature Suction Lift or Suction Head Rated Flow in M3/Hr

35C Flooded suction 1700

P-HG-50236-38-DS

Rev 01

Sl No.

Description

CT Make up Pumps

2.09 2.10 2.11

Pump Total Dynamic Head, MWC Losses in Pump in MWC Pump Shut-off head in MWC (Prefer upto 140% of pump operating head) Range of operation of the pump Rated speed in rpm NPSHR in MWC (at suction flange inlet) Nos. of Stages Pump overall efficiency at Duty point in % Rotation viewed from coupling end Suction specific speed POWER CONSUMPTION

23 NIL 34.56

2.12 2.13 2.14 2.15 2.16 2.17 2.18 3.00

_30 % to __125 % of rated capacity 1486 9.2 1 81.00 % CCW 9945

3.01 3.02

Guaranteed pump shaft input power at rated condition, KW Maximum pump input power at shut-off head Motor kW rating DESIGN AND CONSTRUCTION FEATURES Max. Impeller Diameter in mm Suction nozzle size and rating

131.46 37.3

3.03 4.00 4.01 4.02

150

406.4 MM 350 mm

P-HG-50236-38-DS

Rev 01

Sl No.

Description

CT Make up Pumps

4.03 4.04 4 13 4.14 5.00 5.01 5.02 5.03 5.04 5.05 6.00 6.01 6.02

Discharge nozzle size and rating Type of Pump casing Shaft sealing arrangement sealing liquid Near Field Noise Level MATERIALOFCONSTRUCTION Casing Impeller Shaft Shaft sleeve Base Plate INSPECTION AND TESTING Material Test Hydrostatic test pressure (bar)(1.5 times SOH Duration of test in minutes Vibration PERFORMANCE TEST Performance Testing standard NPSH R test Dynamic balancing test

350 mm Radially Split End Suction Gland packing 85dBA

2 % Ni-Cl to IS 210 FG 260 Stainless steel ASTM -A-351-CF8M. Stainless steel, SS 410 316 Stainless steel MS FAB.

6 15 min HIS

6.03 6.04 7.00 7.01 7.02 7.03

HIS NO Yes

P-HG-50236-38-DS

Rev 01

Sl No.

Description

CT Make up Pumps

8.00 8.01

DRIVE MOTOR Type

Induction Motor 415 V, 3 Phase, 50 HZ, TEFC

8.02 9.00 9.01 9.02

RPM WEIGHT DATA Approximate weight of the pump in Kg Approximate weight of the motor in Kg

1486

1400 kg 1260 kg

P-HG-50236-38-DS

Rev 01

Pump Technical Data Sheet for Misc. Horizontal Pumps Sl No. Description DM Closed Cycle Cooling Water Pump (TG & SG Auxiliaries)

1.00 1.01

GENERAL Designation DM Closed Cycle Cooling Water Pump (TG & SG Auxiliaries)

1.02 1.03

Type of Pump Service

Horizontal centrifugal Passivated DM water

1.04 1.05 1.06 1.07 2.00 2.01 2.02 2.03 2.04 2.05

Pump Duty Pumps to be designed for parallel operation Pump Manufacturer Model / Size TECHNICAL PARAMETERS Performance standard Nos. of Pumps required Nos. of Pumps working Nos. of Pumps standby Liquid handled

Continuous Yes WPIL LIMITED 10LN18A

HIS Twelve (12) Six (6) Six (6) Passivated DM water

2.06 2.07

Design Liquid Temperature Suction Lift or Suction Head

35C Flooded suction

P-HG-50199-210-DS

Rev 01

Sl No.

Description

DM Closed Cycle Cooling Water Pump (TG & SG Auxiliaries)

2.08 2.09 2.10 2.11

Rated Flow in M /Hr Pump Total Dynamic Head, MWC Losses in Pump in MWC Pump Shut-off head in MWC (Prefer upto 140% of pump operating head) Range of operation of the pump Rated speed in rpm NPSHR in MWC (at suction flange inlet) Nos. of Stages Pump overall efficiency at Duty point in % Rotation viewed from coupling end Suction specific speed POWER CONSUMPTION

925 55 NIL 64

2.12 2.13 2.14 2.15 2.16 2.17 2.18 3.00

_30 % to __125 % of rated capacity 1489 4.8 1 86.00 % CCW 11950

3.01 3.02

Guaranteed pump shaft input power at rated condition, KW Maximum pump input power at shut-off head Motor kW rating DESIGN AND CONSTRUCTION FEATURES Max. Impeller Diameter in mm

161.10 90

3.03 4.00 4.01

220

454 MM

P-HG-50199-210-DS

Rev 01

Sl No.

Description

DM Closed Cycle Cooling Water Pump (TG & SG Auxiliaries)

4.02 4.03 4.04 4 13 4.14 5.00 5.01 5.02 5.03 5.04 5.05 6.00 6.01 6.02

Suction nozzle size and rating Discharge nozzle size and rating Type of Pump casing Shaft sealing arrangement sealing liquid Near Field Noise Level MATERIALOFCONSTRUCTION Casing Impeller Shaft Shaft sleeve Base Plate INSPECTION AND TESTING Material Test Hydrostatic test pressure (bar)(1.5 times SOH Duration of test in minutes Vibration PERFORMANCE TEST Performance Testing standard

300 mm 250 mm AXIALLY SPLIT Gland packing 85dBA

2 % Ni-Cl to IS 210 FG 260 Stainless steel ASTM -A-351-CF8M. Stainless steel, SS 410 316 Stainless steel MS FAB.

10

6.03 6.04 7.00 7.01

15 min HIS

HIS

P-HG-50199-210-DS

Rev 01

Sl No.

Description

DM Closed Cycle Cooling Water Pump (TG & SG Auxiliaries)

7.02 7.03

NPSH R test Dynamic balancing test

NO Yes

8.00 8.01

DRIVE MOTOR Type

Induction Motor 6.6 KV, 3 Phase, 50 HZ, TEFC

8.02 9.00 9.01 9.02

RPM WEIGHT DATA Approximate weight of the pump in Kg Approximate weight of the motor in Kg

1489

720 kg 2500 kg

P-HG-50199-210-DS

Rev 01

Pump Technical Data Sheet for Misc. Horizontal Pumps Sl No. Description DM Make-up Pump

1.00 1.01

GENERAL Designation
DM Make-up Pump

1.02 1.03

Type of Pump Service

Horizontal centrifugal DM water (Chemical dosed for PH correction)

1.04 1.05 1.06 1.07 2.00 2.01 2.02 2.03 2.04 2.05

Pump Duty Pumps to be designed for parallel operation Pump Manufacturer Model / Size TECHNICAL PARAMETERS Performance standard Nos. of Pumps required Nos. of Pumps working Nos. of Pumps standby Liquid handled

Continuous Yes WPIL LIMITED WP 50/260

HIS Five (5) Three (3) Two (2) DM water (Chemical dosed for PH correction)

2.06 2.07 2.08

Design Liquid Temperature Suction Lift or Suction Head Rated Flow in M3/Hr

35C Flooded suction 45

P-HG-50194-98-DS

Rev 01

Sl No.

Description

DM Make-up Pump

2.09 2.10 2.11

Pump Total Dynamic Head, MWC Losses in Pump in MWC Pump Shut-off head in MWC (Prefer upto 140% of pump operating head) Range of operation of the pump Rated speed in rpm NPSHR in MWC (at suction flange inlet) Nos. of Stages Pump overall efficiency at Duty point in % Rotation viewed from coupling end Suction specific speed POWER CONSUMPTION

70 NIL 77.5

2.12 2.13 2.14 2.15 2.16 2.17 2.18 3.00

_30 % to __130 % of rated capacity 2960 2.3 1 55.00 % CW 8968

3.01 3.02

Guaranteed pump shaft input power at rated condition, KW Maximum pump input power at shut-off head Motor kW rating DESIGN AND CONSTRUCTION FEATURES Max. Impeller Diameter in mm Suction nozzle size and rating

15.597 8.5

3.03 4.00 4.01 4.02

22

264 MM 80 mm

P-HG-50194-98-DS

Rev 01

Sl No.

Description

DM Make-up Pump

4.03 4.04 4 13 4.14 5.00 5.01 5.02 5.03 5.04 5.05 6.00 6.01 6.02

Discharge nozzle size and rating Type of Pump casing Shaft sealing arrangement sealing liquid Near Field Noise Level MATERIALOFCONSTRUCTION Casing Impeller Shaft Shaft sleeve Base Plate INSPECTION AND TESTING Material Test Hydrostatic test pressure (bar)(1.5 times SOH Duration of test in minutes Vibration PERFORMANCE TEST Performance Testing standard NPSH R test Dynamic balancing test

50 mm BACK PULL OUT Gland packing 85dBA

2 % Ni-Cl to IS 210 FG 260 Stainless steel ASTM -A-351-CF8M. Stainless steel, SS 410 316 Stainless steel MS FAB.

12 15 min HIS

6.03 6.04 7.00 7.01 7.02 7.03

HIS NO Yes

P-HG-50194-98-DS

Rev 01

Sl No.

Description

DM Make-up Pump

8.00 8.01

DRIVE MOTOR Type

Induction Motor 415 V, 3 Phase, 50 HZ, TEFC

8.02 9.00 9.01 9.02

RPM WEIGHT DATA Approximate weight of the pump in Kg Approximate weight of the motor in Kg

2960

123 kg 236 kg

P-HG-50194-98-DS

Rev 01

Pump Technical Data Sheet for Misc. Horizontal Pumps Sl No. Description Plant Smelter Potable Water Pumps

1.00 1.01

GENERAL Designation Plant Smelter Potable Water Pumps

1.02 1.03

Type of Pump Service

Horizontal centrifugal Clarified Water

1.04 1.05 1.06 1.07 2.00 2.01 2.02 2.03 2.04 2.05

Pump Duty Pumps to be designed for parallel operation Pump Manufacturer Model / Size TECHNICAL PARAMETERS Performance standard Nos. of Pumps required Nos. of Pumps working Nos. of Pumps standby Liquid handled

Continuous Yes WPIL LIMITED WP 65/320

HIS Two (2) One (1) One (1) Clarified Water

2.06 2.07

Design Liquid Temperature Suction Lift or Suction Head

35C Flooded suction

P-HG-50241-42-DS

Rev 01

Sl No.

Description

Plant Smelter Potable Water Pumps

2.08 2.09 2.10 2.11

Rated Flow in M /Hr Pump Total Dynamic Head, MWC Losses in Pump in MWC Pump Shut-off head in MWC (Prefer upto 140% of pump operating head) Range of operation of the pump Rated speed in rpm NPSHR in MWC (at suction flange inlet) Nos. of Stages Pump overall efficiency at Duty point in % Rotation viewed from coupling end Suction specific speed POWER CONSUMPTION

100 95 NIL 111

2.12 2.13 2.14 2.15 2.16 2.17 2.18 3.00

_30 % to __125 % of rated capacity 2960 3.5 1 62.00 % CW 9757

3.01 3.02

Guaranteed pump shaft input power at rated condition, KW Maximum pump input power at shut-off head Motor kW rating DESIGN AND CONSTRUCTION FEATURES Max. Impeller Diameter in mm

41.73 23

3.03 4.00 4.01

55

329 MM

P-HG-50241-42-DS

Rev 01

Sl No.

Description

Plant Smelter Potable Water Pumps

4.02 4.03 4.04 4 13 4.14 5.00 5.01 5.02 5.03 5.04 5.05 6.00 6.01 6.02

Suction nozzle size and rating Discharge nozzle size and rating Type of Pump casing Shaft sealing arrangement sealing liquid Near Field Noise Level MATERIALOFCONSTRUCTION Casing Impeller Shaft Shaft sleeve Base Plate INSPECTION AND TESTING Material Test Hydrostatic test pressure (bar)(1.5 times SOH Duration of test in minutes Vibration PERFORMANCE TEST Performance Testing standard

100 mm 65 mm Back Pull Out Gland packing 85dBA

2 % Ni-Cl to IS 210 FG 260 Stainless steel ASTM -A-351-CF8M. Stainless steel, SS 410 316 Stainless steel MS FAB.

19

6.03 6.04 7.00 7.01

15 min HIS

HIS

P-HG-50241-42-DS

Rev 01

Sl No.

Description

Plant Smelter Potable Water Pumps

7.02 7.03

NPSH R test Dynamic balancing test

NO Yes

8.00 8.01

DRIVE MOTOR Type

Induction Motor 415 V, 3 Phase, 50 HZ, TEFC

8.02 9.00 9.01 9.02

RPM WEIGHT DATA Approximate weight of the pump in Kg Approximate weight of the motor in Kg

2960

170 kg 515 kg

P-HG-50241-42-DS

Rev 01

Pump Technical Data Sheet for Misc. Horizontal Pumps Sl No. Description Service Water Pumps

1.00 1.01

GENERAL Designation Service Water Pumps

1.02 1.03

Type of Pump Service

Horizontal centrifugal Clarified Water

1.04 1.05 1.06 1.07 2.00 2.01 2.02 2.03 2.04 2.05

Pump Duty Pumps to be designed for parallel operation Pump Manufacturer Model / Size TECHNICAL PARAMETERS Performance standard Nos. of Pumps required Nos. of Pumps working Nos. of Pumps standby Liquid handled

Continuous Yes WPIL LIMITED WP 100/260

HIS Three (3) Two (2) One (1) Clarified Water

2.06 2.07 2.08

Design Liquid Temperature Suction Lift or Suction Head Rated Flow in M3/Hr

35C Flooded suction 225

P-HG-50233-35-DS

Rev 01

Sl No.

Description

Service Water Pumps

2.09 2.10 2.11

Pump Total Dynamic Head, MWC Losses in Pump in MWC Pump Shut-off head in MWC (Prefer upto 140% of pump operating head) Range of operation of the pump Rated speed in rpm NPSHR in MWC (at suction flange inlet) Nos. of Stages Pump overall efficiency at Duty point in % Rotation viewed from coupling end Suction specific speed POWER CONSUMPTION

87 NIL 95

2.12 2.13 2.14 2.15 2.16 2.17 2.18 3.00

_30 % to __125 % of rated capacity 2970 4.5 1 78.00 % CW 12121

3.01 3.02

Guaranteed pump shaft input power at rated condition, KW Maximum pump input power at shut-off head Motor kW rating DESIGN AND CONSTRUCTION FEATURES Max. Impeller Diameter in mm Suction nozzle size and rating

68.78 35

3.03 4.00 4.01 4.02

90

264 MM 125 mm

P-HG-50233-35-DS

Rev 01

Sl No.

Description

Service Water Pumps

4.03 4.04 4 13 4.14 5.00 5.01 5.02 5.03 5.04 5.05 6.00 6.01 6.02

Discharge nozzle size and rating Type of Pump casing Shaft sealing arrangement sealing liquid Near Field Noise Level MATERIALOFCONSTRUCTION Casing Impeller Shaft Shaft sleeve Base Plate INSPECTION AND TESTING Material Test Hydrostatic test pressure (bar)(1.5 times SOH Duration of test in minutes Vibration PERFORMANCE TEST Performance Testing standard NPSH R test Dynamic balancing test

100 mm BACK PULL OUT Gland packing 85dBA

2 % Ni-Cl to IS 210 FG 260 Stainless steel ASTM -A-351-CF8M. Stainless steel, SS 410 316 Stainless steel MS FAB.

14.3 15 min HIS

6.03 6.04 7.00 7.01 7.02 7.03

HIS NO Yes

P-HG-50233-35-DS

Rev 01

Sl No.

Description

Service Water Pumps

8.00 8.01

DRIVE MOTOR Type

Induction Motor 415 V, 3 Phase, 50 HZ, TEFC

8.02 9.00 9.01 9.02

RPM WEIGHT DATA Approximate weight of the pump in Kg Approximate weight of the motor in Kg

2970

165 kg 940 kg

P-HG-50233-35-DS

Rev 01

Pump Technical Data Sheet for Misc. Horizontal Pumps Sl No. Description Smelter Clarified Water Transfer Pumps

1.00 1.01

GENERAL Designation Smelter Clarified Water Transfer Pumps

1.02 1.03

Type of Pump Service

Horizontal centrifugal Clarified Water

1.04 1.05 1.06 1.07 2.00 2.01 2.02 2.03 2.04 2.05

Pump Duty Pumps to be designed for parallel operation Pump Manufacturer Model / Size TECHNICAL PARAMETERS Performance standard Nos. of Pumps required Nos. of Pumps working Nos. of Pumps standby Liquid handled

Continuous Yes WPIL LIMITED 200DS552A

HIS Two (2) One (1) One (1) Clarified Water

2.06 2.07

Design Liquid Temperature Suction Lift or Suction Head

35C Flooded suction

P-HG-50239-40-DS

Rev 01

Sl No.

Description

Smelter Clarified Water Transfer Pumps

2.08 2.09 2.10 2.11

Rated Flow in M /Hr Pump Total Dynamic Head, MWC Losses in Pump in MWC Pump Shut-off head in MWC (Prefer upto 140% of pump operating head) Range of operation of the pump Rated speed in rpm NPSHR in MWC (at suction flange inlet) Nos. of Stages Pump overall efficiency at Duty point in % Rotation viewed from coupling end Suction specific speed POWER CONSUMPTION

450 80 NIL 95

2.12 2.13 2.14 2.15 2.16 2.17 2.18 3.00

_30 % to __125 % of rated capacity 1485 3 1 72.00 % CW 11897

3.01 3.02

Guaranteed pump shaft input power at rated condition, KW Maximum pump input power at shut-off head Motor kW rating DESIGN AND CONSTRUCTION FEATURES Max. Impeller Diameter in mm

136.16 125

3.03 4.00 4.01

160

564 MM

P-HG-50239-40-DS

Rev 01

Sl No.

Description

Smelter Clarified Water Transfer Pumps

4.02 4.03 4.04 4 13 4.14 5.00 5.01 5.02 5.03 5.04 5.05 6.00 6.01 6.02

Suction nozzle size and rating Discharge nozzle size and rating Type of Pump casing Shaft sealing arrangement sealing liquid Near Field Noise Level MATERIALOFCONSTRUCTION Casing Impeller Shaft Shaft sleeve Base Plate INSPECTION AND TESTING Material Test Hydrostatic test pressure (bar)(1.5 times SOH Duration of test in minutes Vibration PERFORMANCE TEST Performance Testing standard

250 mm 200 mm Back Pull Out Gland packing 85dBA

2 % Ni-Cl to IS 210 FG 260 Stainless steel ASTM -A-351-CF8M. Stainless steel, SS 410 316 Stainless steel MS FAB.

15

6.03 6.04 7.00 7.01

15 min HIS

HIS

P-HG-50239-40-DS

Rev 01

Sl No.

Description

Smelter Clarified Water Transfer Pumps

7.02 7.03

NPSH R test Dynamic balancing test

NO Yes

8.00 8.01

DRIVE MOTOR Type

Induction Motor 415 V, 3 Phase, 50 HZ, TEFC

8.02 9.00 9.01 9.02

RPM WEIGHT DATA Approximate weight of the pump in Kg Approximate weight of the motor in Kg

1485

525 kg 1260 kg

P-HG-50239-40-DS

Rev 01

Pump Technical Data Sheet for Misc. Horizontal Pumps Sl No. Description Station ACW Booster Pump

1.00 1.01

GENERAL Designation
Station ACW Booster Pump

1.02 1.03

Type of Pump Service

Horizontal centrifugal Clarified Water

1.04 1.05 1.06 1.07 2.00 2.01 2.02 2.03 2.04 2.05

Pump Duty Pumps to be designed for parallel operation Pump Manufacturer Model / Size TECHNICAL PARAMETERS Performance standard Nos. of Pumps required Nos. of Pumps working Nos. of Pumps standby Liquid handled

Continuous Yes WPIL LIMITED WP 150/320

HIS Four (4) Three (3) One (1) Clarified Water

2.06 2.07 2.08

Design Liquid Temperature Suction Lift or Suction Head Rated Flow in M3/Hr

35C Flooded suction 350

P-HG-50229-32-DS

Rev 01

Sl No.

Description

Station ACW Booster Pump

2.09 2.10 2.11

Pump Total Dynamic Head, MWC Losses in Pump in MWC Pump Shut-off head in MWC (Prefer upto 140% of pump operating head) Range of operation of the pump Rated speed in rpm NPSHR in MWC (at suction flange inlet) Nos. of Stages Pump overall efficiency at Duty point in % Rotation viewed from coupling end Suction specific speed POWER CONSUMPTION

30 NIL 33

2.12 2.13 2.14 2.15 2.16 2.17 2.18 3.00

_30 % to __130 % of rated capacity 1475 3.1 1 86.00 % CW 9996

3.01 3.02

Guaranteed pump shaft input power at rated condition, KW Maximum pump input power at shut-off head Motor kW rating DESIGN AND CONSTRUCTION FEATURES Max. Impeller Diameter in mm Suction nozzle size and rating

33.25 13

3.03 4.00 4.01 4.02

45

329 MM 200 mm

P-HG-50229-32-DS

Rev 01

Sl No.

Description

Station ACW Booster Pump

4.03 4.04 4 13 4.14 5.00 5.01 5.02 5.03 5.04 5.05 6.00 6.01 6.02

Discharge nozzle size and rating Type of Pump casing Shaft sealing arrangement sealing liquid Near Field Noise Level MATERIALOFCONSTRUCTION Casing Impeller Shaft Shaft sleeve Base Plate INSPECTION AND TESTING Material Test Hydrostatic test pressure (bar)(1.5 times SOH Duration of test in minutes Vibration PERFORMANCE TEST Performance Testing standard NPSH R test Dynamic balancing test

150 mm BACK PULL OUT Gland packing 85dBA

2 % Ni-Cl to IS 210 FG 260 Stainless steel ASTM -A-351-CF8M. Stainless steel, SS 410 316 Stainless steel MS FAB.

5 15 min HIS

6.03 6.04 7.00 7.01 7.02 7.03

HIS NO Yes

P-HG-50229-32-DS

Rev 01

Sl No.

Description

Station ACW Booster Pump

8.00 8.01

DRIVE MOTOR Type

Induction Motor 415 V, 3 Phase, 50 HZ, TEFC

8.02 9.00 9.01 9.02

RPM WEIGHT DATA Approximate weight of the pump in Kg Approximate weight of the motor in Kg

1475

338 kg 415 kg

P-HG-50229-32-DS