Product data sheet

3RP2005-1BW30
SOLID-STATE TIME-DELAY RELAY MULTI-FUNCTION, 16 FUNCTIONS 2 CHANGEOVER CONTACTS AC/DC 24 TO 240V 0.05 S TO 100H WIDTH 45MM SCREW TERMINALS

General technical details:


product brand name product designation Protection class IP / on the front Protection class IP / of the terminal mounting position Supply voltage frequency 1 / for auxiliary and control current circuit initial rated value final rated value Product function star-delta circuit with auxiliary voltage / pulse-shaping at the relay outputs / changeover delayed/without delay Product component / semi-conductor output Product extension / optional / remote control Product extension / strictly required / remote control Installation altitude / at a height over sea level / maximum Ambient temperature during storage C -40 +85 m Yes Yes No No No No 2,000 Hz Hz 50 60 SIRIUS timing relay IP40 IP20 any

3RP2005-1BW30 Page 1/ 5

11/20/2012

subject to modifications Copyright Siemens AG 2012

during operating during transport Relative humidity during operating phase

C C

-25 +60 -40 +85

15 70 2 kV network connection / 1 kV control connection

Conductor-bound parasitic coupling conductor-earth SURGE / according to IEC 61000-4-5 Conductor-bound parasitic coupling conductor-conductor SURGE / according to IEC 61000-4-5 Electrostatic discharge / according to IEC 61000-4-2 Field-bound parasitic coupling / according to IEC 61000-4-3 Resistance against vibration Impulse voltage resistance / rated value Insulation voltage / rated value Active power loss / total / typical Item designation / according to DIN 40719 extendable after IEC 204-2 / according to IEC 750 Item designation / according to DIN EN 61346-2 Category / according to EN 954-1 Protection against electrical shock V V W

2 kV

1 kV

4 kV contact discharge / 8 kV air discharge 10 V/m 10 ... 55 Hz / 0.35 mm 4,000 300 2 K

K none finger-safe

Switching Function:
Switching function slow-operating making pulse contact firmly clocked beginning with pulse firmly clocked beginning with pause relapse delayed variably clocked start with impulse impuls variably clocked start with pause with auxiliary voltage in an additive way slow-operating temporary line fault relapse delayed without auxiliary voltage / relapse delayed slow-operating/instantaneous contact with auxiliary voltage relapse delayed/instantaneous contact slow-operating/relapse delayed/instantaneous contact firmly clocked beginning with pause/instantaneous contact making pulse contact/instantaneous contact Yes Yes Yes Yes Yes Yes Yes No Yes Yes No No Yes Yes No No

3RP2005-1BW30 Page 2/ 5

11/20/2012

subject to modifications Copyright Siemens AG 2012

with auxiliary voltage temporary line fault/instantaneous contact pulse modelling/instantaneous contact slow-operating/instantaneous contact Yes Yes Yes

General details:
Type of voltage / of the controlled supply voltage Control supply voltage frequency 1 Control supply voltage 1 at 50 Hz for AC at 60 Hz for AC for DC Operating range factor control supply voltage rated value at 50 Hz for AC at 60 Hz for AC for DC 0.8 1.1 0.85 1.1 0.8 1.1 V V 24 240 24 240 V 24 240 Hz 50 60 AC/DC

Auxiliary circuit:
Operating current / of auxiliary contacts as normally closed contact / for AC-15 at 24 V at 250 V as normally open contact / for AC-15 at 24 V at 250 V at AC-15 maximum at DC-13 at 24 V at 125 V at 250 V Number of NC contacts / delayed switching Number of NC contacts / non-delayed Number of NO contacts / delayed switching A A A 1 0.2 0.1 0 0 0 A 3 A A 3 3 A A 3 3

3RP2005-1BW30 Page 3/ 5

11/20/2012

subject to modifications Copyright Siemens AG 2012

Number of NO contacts / non-delayed Number of change-over switches / delayed switching Number of change-over switches / non-delayed

0 2 0

Short-circuit:
Design of the fuse link / for short-circuit protection of the auxiliary switch / required Type of mounting fuse gL/gG: 4 A

screw and snap-on mounting onto 35 mm standard mounting rail

Installation/mounting/dimensions:
Width Height Depth Distance, to be maintained, to the ranks assembly upwards forwards sidewards backwards downwards Distance, to be maintained, to earthed part backwards sidewards upwards forwards downwards Distance, to be maintained, conductive elements downwards backwards sidewards forwards upwards mm mm mm mm mm 0 0 0 0 0 mm mm mm mm mm 0 0 0 0 0 mm mm mm mm mm 0 0 0 0 0 mm mm mm 45 57 73

Connections:
Design of the snap-on socket base Design of the electrical connection jumper socket for auxiliary and control current circuit Type of the connectable conductor cross-section / for AWG conductors / for auxiliary contacts AWG number / as coded connectable conductor cross-section / for auxiliary contact No screw-type terminals 2x (20 ... 16) none

3RP2005-1BW30 Page 4/ 5

11/20/2012

subject to modifications Copyright Siemens AG 2012

minimum maximum

20 16

Certificates/approvals:
Verification of suitability General Product Approval EMC CE / UL / CSA Declaration of Conformity Test Certificates

Special Test Certificate

Shipping Approval

Shipping Approval

other Environmental Confirmations

Further information:
Information- and Downloadcenter (Catalogs, Brochures,) http://www.siemens.com/industrial-controls/catalogs Industry Mall (Online ordering system) http://www.siemens.com/industrial-controls/mall CAx-Online-Generator http://www.siemens.com/cax Service&Support (Manuals, Certificates, Characteristics, FAQs,...) http://support.automation.siemens.com/WW/view/en/3RP2005-1BW30/all Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3RP2005-1BW30

last change:

Sep 10, 2012

3RP2005-1BW30 Page 5/ 5

11/20/2012

subject to modifications Copyright Siemens AG 2012

You might also like