PHYSICAL PROPERTIES

Minimum yield strength 80,000 psi


Minimum tensile strength 88,000 psi
Minimum Elongation 28%
Maximum Hardness 22C Rockwell

CHEMICAL COMPOSITION - %

Carbon 0.10 0.15 range


Manganese 0.60 0.90 range
Phosphorus 0.03 max
Sulfur 0.005 max
Silicon 0.30 0.50 range
Chromium 0.45 0.70 range
Copper 0.40 max
Nickel 0.25 max

STEEL ALLOY DESCRIPTION

A-606 type 4 modified

CONTACT INFO
Tenaris Coiled Tubes
8615 E. Sam Houston Pkwy N.
77044 Houston Texas USA
coiledtubesales@tenaris.com
(1) 281 458 2883 tel
(1) 281 458 2886 fax

HS-80 GRADE*
DIMENSIONS
(Inches)

NOMINAL
WEIGHT
Lbs. / ft.

O.D.
SPECIFIED

O.D.
(mm)

WALL
SPECIFIED

WALL
(mm)

WALL
MINIMUM

I.D.
CALCULATED

1.000

25.4

1.250

31.8

1.500

38.1

1.750

44.5

2.000

50.8

2.375

60.3

0.080
0.087
0.095
0.102
0.109
0.080
0.087
0.095
0.102
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.095
0.102
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.125
0.134
0.145
0.156
0.175
0.190
0.204

2.03
2.21
2.41
2.59
2.77
2.03
2.21
2.41
2.59
2.77
2.95
3.18
3.40
3.68
3.96
4.45
2.41
2.59
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
5.18
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
5.18
3.18
3.40
3.68
3.96
4.45
4.83
5.18

0.076
0.083
0.090
0.097
0.104
0.076
0.083
0.090
0.097
0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.090
0.097
0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.195
0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.195
0.120
0.128
0.138
0.148
0.167
0.180
0.195

0.840
0.826
0.810
0.796
0.782
1.090
1.076
1.060
1.046
1.032
1.018
1.000
0.982
0.960
0.938
0.900
1.310
1.296
1.282
1.268
1.250
1.232
1.210
1.188
1.150
1.120
1.532
1.518
1.500
1.482
1.460
1.438
1.400
1.370
1.342
1.782
1.768
1.750
1.732
1.710
1.688
1.650
1.620
1.592
2.125
2.107
2.085
2.063
2.025
1.995
1.967

0.788
0.850
0.920
0.981
1.040
1.002
1.083
1.175
1.254
1.332
1.408
1.506
1.601
1.715
1.827
2.014
1.429
1.527
1.623
1.719
1.840
1.960
2.104
2.245
2.483
2.665
1.915
2.029
2.175
2.318
2.492
2.662
2.951
3.173
3.377
2.207
2.340
2.509
2.677
2.880
3.080
3.419
3.682
3.923
3.011
3.215
3.462
3.706
4.122
4.445
4.742

TUBE LOAD BODY


(Lbs.)

INTERNAL
PRESSURE (psi)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. Ibs.)

INTERNAL
CAPACITY
per 1000 ft.

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

W/ MIN.
WALL

INTERNAL
MIN

YIELD

ULTIMATE

GALLONS

BARRELS

18,500
20,000
21,600
23,000
24,400
23,500
25,400
27,600
29,400
31,300
33,100
35,300
37,600
40,300
42,900
47,300
33,500
35,800
38,100
40,300
43,200
46,000
49,400
52,700
58,300
62,600
45,000
47,600
51,100
54,400
58,500
62,500
69,300
74,500
79,300
51,800
54,900
58,900
62,800
67,600
72,300
80,300
86,400
92,100
70,700
75,500
81,300
87,000
96,800
104,300
111,300

20,300
22,000
23,800
25,300
26,800
25,900
28,000
30,300
32,400
34,400
36,400
38,900
41,300
44,300
47,200
52,000
36,900
39,400
41,900
44,400
47,500
50,600
54,300
58,000
64,100
68,800
49,500
52,400
56,200
59,900
64,300
68,700
76,200
81,900
87,200
57,000
60,400
64,800
69,100
74,400
79,500
88,300
95,100
101,300
77,800
83,000
89,400
95,700
106,400
114,800
122,400

10,800
11,700
12,700
13,600
14,600
8,700
9,500
10,200
11,000
11,800
12,500
13,500
14,400
15,400
16,500
18,400
8,600
9,200
9,900
10,500
11,300
12,100
13,000
13,900
15,500
16,700
8,500
9,000
9,700
10,400
11,200
12,000
13,400
14,400
15,500
7,400
7,900
8,600
9,100
9,800
10,500
11,800
12,700
13,700
7,200
7,700
8,300
8,900
10,000
10,800
11,600

12,000
13,000
14,100
15,200
16,200
9,600
10,500
11,400
12,200
13,100
13,900
15,000
16,000
17,100
18,300
20,400
9,500
10,200
11,000
11,700
12,600
13,400
14,400
15,400
17,300
18,500
9,400
10,000
10,800
11,500
12,400
13,300
14,900
16,000
17,300
8,300
8,800
9,500
10,100
10,900
11,700
13,100
14,100
15,200
8,000
8,600
9,200
9,900
11,100
12,000
12,900

0.221
0.239
0.257
0.275
0.293
0.280
0.304
0.328
0.351
0.374
0.397
0.426
0.451
0.482
0.512
0.568
0.399
0.428
0.456
0.484
0.520
0.552
0.590
0.629
0.699
0.746
0.538
0.572
0.614
0.652
0.699
0.745
0.831
0.888
0.953
0.619
0.659
0.709
0.753
0.807
0.861
0.962
1.029
1.106
0.850
0.904
0.970
1.035
1.158
1.241
1.335

0.565
0.546
0.528
0.510
0.493
0.947
0.923
0.899
0.876
0.853
0.830
0.801
0.776
0.745
0.715
0.659
1.368
1.340
1.311
1.283
1.247
1.215
1.177
1.139
1.068
1.021
1.867
1.834
1.791
1.753
1.706
1.660
1.575
1.517
1.453
2.522
2.483
2.433
2.389
2.334
2.280
2.180
2.112
2.036
3.580
3.527
3.460
3.395
3.272
3.189
3.095

365
390
414
437
458
597
641
683
724
763
800
846
885
931
975
1,050
1,020
1,084
1,146
1,206
1,280
1,343
1,419
1,491
1,618
1,699
1,608
1,695
1,804
1,898
2,011
2,119
2,313
2,437
2,571
2,148
2,268
2,419
2,549
2,706
2,858
3,133
3,310
3,505
3,511
3,707
3,945
4,177
4,600
4,876
5,181

393
423
452
480
507
634
684
733
781
828
873
929
978
1,036
1,093
1,193
1,083
1,156
1,227
1,297
1,384
1,460
1,552
1,641
1,802
1,907
1,705
1,804
1,930
2,039
2,172
2,302
2,538
2,693
2,864
2,261
2,396
2,566
2,715
2,896
3,074
3,400
3,614
3,854
3,691
3,909
4,178
4,442
4,929
5,252
5,614

28.79
27.84
26.77
25.85
24.95
48.47
47.24
45.84
44.64
43.45
42.28
40.80
39.34
37.60
35.90
33.05
70.02
68.53
67.06
65.60
63.75
61.93
59.74
57.58
53.96
51.18
95.76
94.02
91.80
89.61
86.97
84.37
79.97
76.58
73.48
129.56
127.53
124.95
122.39
119.30
116.25
111.08
107.08
103.41
184.24
181.13
177.37
173.64
167.31
162.38
157.86

0.69
0.66
0.64
0.62
0.59
1.15
1.12
1.09
1.06
1.03
1.01
0.97
0.94
0.90
0.85
0.79
1.67
1.63
1.60
1.56
1.52
1.47
1.42
1.37
1.28
1.22
2.28
2.24
2.19
2.13
2.07
2.01
1.90
1.82
1.75
3.08
3.04
2.97
2.91
2.84
2.77
2.64
2.55
2.46
4.39
4.31
4.22
4.13
3.98
3.87
3.76

*Selected coiled tubing data


(80 Kpsi Min. Yield Strength; 88 Kpsi Min. Tensile Strength; 28% Min. Elongation; Loads calculated using nom. wall)

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS
40.80
40.80
40.80
40.80
40.80
63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75
91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80
124.95
124.95
124.95
124.95
124.95
124.95
124.95
124.95
124.95
163.20
163.20
163.20
163.20
163.20
163.20
163.20
163.20
163.20
230.14
230.14
230.14
230.14
230.14
230.14
230.14

BARRELS
0.97
0.97
0.97
0.97
0.97
1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.97
2.97
2.97
2.97
2.97
2.97
2.97
2.97
2.97
3.89
3.89
3.89
3.89
3.89
3.89
3.89
3.89
3.89
5.48
5.48
5.48
5.48
5.48
5.48
5.48

Test pressure value equals 90% of internal yield pressure rating. Maximum working pressure is a function of tube condition and is determined
by user. All data is for new tubing at minimum strength. * Available as continuously milled tubing (CM) or conventional butt-welded tubing
sections (W). See individual size sheets for additional wall thicknesses. 2-5/8", 2-7/8", and other sizes not shown are also available.

HS-80 GRADE* METRIC VALUES


DIMENSIONS
(mm)

NOMINAL
WEIGHT
Kg/m

O.D.
SPECIFIED

O.D.
(inches)

WALL
SPECIFIED

WALL
(inches)

WALL
MINIMUM

I.D.
CALCULATED

25.4

1.000

31.8

1.250

38.1

1.500

44.5

1.750

50.8

2.000

60.3

2.375

2.03
2.21
2.41
2.59
2.77
2.03
2.21
2.41
2.59
2.77
2.95
3.18
3.40
3.68
3.96
4.45
2.41
2.59
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
5.18
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
5.18
3.18
3.40
3.68
3.96
4.45
4.83
5.18

0.080
0.087
0.095
0.102
0.109
0.080
0.087
0.095
0.102
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.095
0.102
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.125
0.134
0.145
0.156
0.175
0.190
0.204

1.93
2.11
2.29
2.46
2.64
1.93
2.11
2.29
2.46
2.64
2.82
3.05
3.25
3.51
3.76
4.24
2.29
2.46
2.64
2.82
3.05
3.25
3.51
3.76
4.24
4.57
2.64
2.82
3.05
3.25
3.51
3.76
4.24
4.57
4.95
2.64
2.82
3.05
3.25
3.51
3.76
4.24
4.57
4.95
3.05
3.25
3.51
3.76
4.24
4.57
4.95

21.3
21.0
20.6
20.2
19.9
27.7
27.3
26.9
26.6
26.2
25.9
25.4
24.9
24.4
23.8
22.9
33.3
32.9
32.6
32.2
31.8
31.3
30.7
30.2
29.2
28.4
38.9
38.6
38.1
37.6
37.1
36.5
35.6
34.8
34.1
45.3
44.9
44.5
44.0
43.4
42.9
41.9
41.1
40.4
54.0
53.5
53.0
52.4
51.4
50.7
50.0

1.17
1.26
1.37
1.46
1.55
1.49
1.61
1.75
1.86
1.98
2.09
2.24
2.38
2.55
2.72
2.99
2.12
2.27
2.41
2.55
2.73
2.91
3.13
3.34
3.69
3.96
2.85
3.02
3.23
3.45
3.70
3.96
4.39
4.72
5.02
3.28
3.48
3.73
3.98
4.28
4.58
5.08
5.47
5.83
4.47
4.78
5.14
5.51
6.13
6.61
7.05

TUBE LOAD BODY


(Newtons)

INTERNAL
PRESSURE (kPa)

TUBING AREA
(sq. cm)

TORSIONAL
YIELD
(N-m)

INTERNAL
CAPACITY

EXTERNAL
DISPLACEMENT

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

W/ MIN.
WALL

INTERNAL
MIN

YIELD

ULTIMATE

LITERS / METER

LITERS / METER

82,300
89,000
96,100
102,300
108,500
104,500
113,000
122,800
130,800
139,200
147,200
157,000
167,200
179,300
190,800
210,400
149,000
159,200
169,500
179,300
192,200
204,600
219,700
234,400
259,300
278,400
200,200
211,700
227,300
242,000
260,200
278,000
308,200
331,400
352,700
230,400
244,200
262,000
279,300
300,700
321,600
357,200
384,300
409,700
314,500
335,800
361,600
387,000
430,600
463,900
495,100

90,300
97,900
105,900
112,500
119,200
115,200
124,500
134,800
144,100
153,000
161,900
173,000
183,700
197,000
209,900
231,300
164,100
175,300
186,400
197,500
211,300
225,100
241,500
258,000
285,100
306,000
220,200
233,100
250,000
266,400
286,000
305,600
338,900
364,300
387,900
253,500
268,700
288,200
307,400
330,900
353,600
392,800
423,000
450,600
346,100
369,200
397,700
425,700
473,300
510,600
544,400

74,500
80,700
87,600
93,800
100,700
60,000
65,500
70,300
75,800
81,400
86,200
91,700
99,300
106,200
113,800
126,900
59,300
63,400
68,300
72,400
77,200
83,400
89,600
95,800
106,900
115,100
58,600
62,100
66,200
71,700
77,200
82,700
92,400
99,300
106,900
51,000
54,500
57,900
62,700
67,600
72,400
81,400
87,600
94,500
49,000
53,100
57,200
61,400
69,000
74,500
80,000

82,700
89,600
97,200
104,800
111,700
66,200
72,400
78,600
84,100
90,300
95,800
102,000
110,300
117,900
126,200
140,700
65,500
70,300
75,800
80,700
85,500
92,400
99,300
106,200
119,300
127,600
64,800
69,000
73,800
79,300
85,500
91,700
102,700
110,300
119,300
57,200
60,700
64,800
69,600
75,200
80,700
90,300
97,200
104,800
54,500
59,300
63,400
68,300
76,500
82,700
88,900

1.42
1.54
1.66
1.78
1.89
1.81
1.96
2.12
2.27
2.42
2.56
2.75
2.91
3.11
3.31
3.67
2.57
2.76
2.94
3.12
3.35
3.56
3.81
4.06
4.51
4.82
3.47
3.69
3.96
4.21
4.51
4.81
5.36
5.73
6.15
4.00
4.25
4.57
4.86
5.21
5.56
6.20
6.64
7.13
5.48
5.83
6.26
6.68
7.47
8.01
8.62

3.64
3.52
3.41
3.29
3.18
6.11
5.95
5.80
5.65
5.50
5.35
5.17
5.01
4.81
4.61
4.25
8.83
8.64
8.46
8.28
8.05
7.84
7.59
7.35
6.89
6.59
12.05
11.83
11.55
11.31
11.01
10.71
10.16
9.79
9.37
16.27
16.02
15.70
15.41
15.06
14.71
14.06
13.63
13.13
23.10
22.75
22.32
21.90
21.11
20.57
19.97

490
530
560
590
620
810
870
930
980
1,030
1,090
1,150
1,200
1,260
1,320
1,420
1,380
1,470
1,550
1,640
1,740
1,820
1,920
2,020
2,190
2,300
2,180
2,300
2,450
2,570
2,730
2,870
3,140
3,300
3,490
2,910
3,080
3,280
3,460
3,670
3,880
4,250
4,490
4,750
4,760
5,030
5,350
5,660
6,240
6,610
7,030

530
570
610
650
690
860
930
990
1,060
1,120
1,180
1,260
1,330
1,410
1,480
1,620
1,470
1,570
1,660
1,760
1,880
1,980
2,100
2,230
2,440
2,590
2,310
2,450
2,620
2,760
2,950
3,120
3,440
3,650
3,880
3,070
3,250
3,480
3,680
3,930
4,170
4,610
4,900
5,230
5,010
5,300
5,670
6,020
6,680
7,120
7,610

0.36
0.35
0.33
0.32
0.31
0.60
0.59
0.57
0.55
0.54
0.53
0.51
0.49
0.47
0.45
0.41
0.87
0.85
0.83
0.81
0.79
0.77
0.74
0.72
0.67
0.64
1.19
1.17
1.14
1.11
1.08
1.05
0.99
0.95
0.91
1.61
1.58
1.55
1.52
1.48
1.44
1.38
1.33
1.28
2.29
2.25
2.20
2.16
2.08
2.02
1.96

0.51
0.51
0.51
0.51
0.51
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.55
1.55
1.55
1.55
1.55
1.55
1.55
1.55
1.55
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.86
2.86
2.86
2.86
2.86
2.86
2.86

*Selected coiled tubing data - Metric values


(552 N/mm2 Min. Yield Strength; 607 N/mm2 Min. Tensile Strength; 28 % Min. Elongation; Loads calculated using nom. wall)

Test pressure value equals 90% of internal yield pressure rating. Maximum working pressure is a function of tube condition and is determined
by user. All data is for new tubing at minimum strength. * Available as continuously milled tubing (CM) or conventional butt-welded tubing
sections (W). 66.7mm and 73.0mm, and other sizes not shown are also available.

Coiled Tubing Data .75" O.D.


HS-80 CM* or HS-80 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

0.75

0.080
0.087
0.095
0.102
0.109

0.076
0.083
0.090
0.097
0.104

0.590
0.576
0.560
0.546
0.532

TUBE BODY LOAD


(Lbs.)

NOMINAL
WEIGHT
(lbs / ft)

0.574
0.618
0.666
0.708
0.748

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

13,500
14,500
15,600
16,600
17600

14,800
15,900
17,200
18,300
19,300

14,200
15,500
16,700
17,800
19,000

15,800
17,200
18,500
19,800
21,100

HS-80 CM* or HS-80 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

INTERNAL
CAPACITY
per 1000 ft.

TORSIONAL
YIELD
(ft. / Lbs.)

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

0.75

0.076
0.083
0.090
0.097
0.104

0.161
0.174
0.187
0.199
0.211

0.281
0.268
0.255
0.243
0.231

190
201
212
222
232

209
224
238
252
265

14.20
13.54
12.79
12.16
11.55

0.34
0.32
0.30
0.29
0.27

GALLONS

22.95
22.95
22.95
22.95
22.95

BARRELS

0.55
0.55
0.55
0.55
0.55

* Continuously milled tubing.


** Butt-welded tube sections.

HS-80 CM or HS-80 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 1" O.D.


HS-80 CM* or HS-80 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

1.000

0.080
0.087
0.095
0.102
0.109

0.076
0.083
0.090
0.097
0.104

0.840
0.826
0.810
0.796
0.782

TUBE BODY LOAD


(Lbs.)

NOMINAL
WEIGHT
(lbs / ft)

0.788
0.850
0.920
0.981
1.040

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

18,500
20,000
21,600
23,000
24,400

20,300
22,000
23,800
25,300
26,800

10,800
11,700
12,700
13,600
14,600

12,000
13,000
14,100
15,200
16,200

HS-80 CM* or HS-80 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

INTERNAL
CAPACITY
per 1000 ft.

TORSIONAL
YIELD
(ft. / Lbs.)

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

GALLONS

BARRELS

1.000

0.076
0.083
0.090
0.097
0.104

0.221
0.239
0.257
0.275
0.293

0.565
0.546
0.528
0.510
0.493

365
390
414
437
458

393
423
452
480
507

28.79
27.84
26.77
25.85
24.95

0.69
0.66
0.64
0.62
0.59

40.80
40.80
40.80
40.80
40.80

0.97
0.97
0.97
0.97
0.97

* Continuously milled tubing.


** Butt-welded tube sections.

HS-80 CM or HS-80 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 1.25" O.D.


HS-80 CM* or HS-80 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

l.250

0.080
0.087
0.095
0.102
0.109
0.116
0.125
0.134
0.145
0.156
0.175

0.076
0.083
0.090
0.097
0.104
0.111
0.120
0.128
0.138
0.148
0.167

1.090
1.076
1.060
1.046
1.032
1.018
1.000
0.982
0.960
0.938
0.900

NOMINAL
WEIGHT
(lbs / ft)

1.002
1.083
1.175
1.254
1.332
1.408
1.506
1.601
1.715
1.827
2.014

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

23,500
25,400
27,600
29,400
31,300
33,100
35,300
37,600
40,300
42,900
47,300

25,900
28,000
30,300
32,400
34,400
36,400
38,900
41,300
44,300
47,200
52,000

8,700
9,500
10,200
11,000
11,800
12,500
13,500
14,400
15,400
16,500
18,400

9,600
10,500
11,400
12,200
13,100
13,900
15,000
16,000
17,100
18,300
20,400

HS-80 CM* or HS-80 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

l.250

0.076
0.083
0.090
0.097
0.104
0.111
0.120
0.128
0.138
0.148
0.167

0.280
0.304
0.328
0.351
0.374
0.397
0.426
0.451
0.482
0.512
0.568

0.947
0.923
0.899
0.876
0.853
0.830
0.801
0.776
0.745
0.715
0.659

597
641
683
724
763
800
846
885
931
975
1,050

634
684
733
781
828
873
929
978
1,036
1,093
1,193

48.47
47.24
45.84
44.64
43.45
42.28
40.80
39.34
37.60
35.90
33.05

1.15
1.12
1.09
1.06
1.03
1.01
0.97
0.94
0.90
0.85
0.79

GALLONS

63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75

BARRELS

1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52

* Continuously milled tubing.


** Butt-welded tube sections.

HS-80 CM or HS-80 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 1.50" O.D.


HS-80 CM* or HS-80 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

1.500

0.095
0.102
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190

0.090
0.097
0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180

1.310
1.296
1.282
1.268
1.250
1.232
1.210
1.188
1.150
1.120

NOMINAL
WEIGHT
(lbs / ft)

1.429
1.527
1.623
1.719
1.840
1.960
2.104
2.245
2.483
2.665

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

33,500
35,800
38,100
40,300
43,200
46,600
49,400
52,700
58,300
62,600

36,900
39,400
41,900
44,400
47,500
50,600
54,300
58,000
64,100
68,800

8,600
9,200
9,900
10,500
11,300
12,100
13,000
13,900
15,500
16,700

9,500
10,200
11,000
11,700
12,600
13,400
14,400
15,400
17,300
18,500

HS-80 CM* or HS-80 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

1.500

0.090
0.097
0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180

0.399
0.428
0.456
0.484
0.520
0.552
0.590
0.629
0.699
0.746

1.368
1.340
1.311
1.283
1.247
1.215
1.177
1.139
1.068
1.021

1,020
1,084
1,146
1,206
1,280
1,343
1,419
1,491
1,619
1,699

1,083
1,156
1,227
1,297
1,384
1,460
1,552
1,641
1,802
1,907

70.02
68.53
67.06
65.60
63.75
61.93
59.74
57.58
53.96
51.18

1.67
1.63
1.60
1.56
1.52
1.47
1.42
1.37
1.28
1.22

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS

91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80

BARRELS

2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19

* Continuously milled tubing.


** Butt-welded tube sections.

HS-80 CM or HS-80 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 1.75" O.D.


HS-80 CM* or HS-80 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

1.750

0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204

0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.195

1.532
1.518
1.500
1.482
1.460
1.438
1.400
1.370
1.342

NOMINAL
WEIGHT
(lbs / ft)

1.915
2.029
2.175
2.318
2.492
2.662
2.951
3.173
3.377

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

45,000
47,600
51,100
54,400
58,500
62,500
69,300
74,500
79,300

49,500
52,400
56,200
59,900
64,300
68,700
76,200
81,900
87,200

8,500
9,000
9,700
10,400
11,200
12,000
13,400
14,400
15,500

9,400
10,000
10,800
11,500
12,400
13,300
14,900
16,000
17,300

HS-80 CM* or HS-80 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

1.750

0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.195

0.538
0.572
0.614
0.652
0.699
0.745
0.831
0.888
0.953

1.867
1.834
1.791
1.753
1.706
1.660
1.575
1.517
1.453

1,608
1,695
1,804
1,898
2,011
2,119
2,313
2,437
2,571

1,705
1,804
1,930
2,039
2,172
2,302
2,538
2,693
2,864

95.76
94.02
91.80
89.61
86.97
84.37
79.97
76.58
73.48

BARRELS

2.28
2.24
2.19
2.13
2.07
2.01
1.90
1.82
1.75

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS

124.95
124.95
124.95
124.95
124.95
124.95
124.95
124.95
124.95

BARRELS

2.97
2.97
2.97
2.97
2.97
2.97
2.97
2.97
2.97

* Continuously milled tubing.


** Butt-welded tube sections.

HS-80 CM or HS-80 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 2.00" O.D.


HS-80 CM* or HS-80 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

2.000

0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204

0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.195

1.782
1.768
1.750
1.732
1.710
1.688
1.650
1.620
1.592

NOMINAL
WEIGHT
(lbs / ft)

2.207
2.340
2.509
2.677
2.880
3.080
3.419
3.682
3.923

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

51,800
54,900
58,900
62,800
67,600
72,300
80,300
86,400
92,100

57,000
60,400
64,800
69,100
74,400
79,500
88,300
95,100
101,300

7,400
7,900
8,600
9,100
9,800
10,500
11,800
12,700
13,700

8,300
8,800
9,500
10,100
10,900
11,700
13,100
14,100
15,200

HS-80 CM* or HS-80 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

2.000

0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.195

0.619
0.659
0.709
0.753
0.807
0.861
0.962
1.029
1.106

2.522
2.483
2.433
2.389
2.334
2.280
2.180
2.112
2.036

2,148
2,268
2,419
2,549
2,706
2,858
3,133
3,310
3,505

2,261
2,396
2,566
2,715
2,896
3,074
3,400
3,614
3,854

129.56
127.53
124.95
122.39
119.30
116.25
111.08
107.08
103.41

3.08
3.04
2.97
2.91
2.84
2.77
2.64
2.55
2.46

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS

163.20
163.20
163.20
163.20
163.20
163.20
163.20
163.20
163.20

BARRELS

3.89
3.89
3.89
3.89
3.89
3.89
3.89
3.89
3.89

* Continuously milled tubing.


** Butt-welded tube sections.

HS-80 CM or HS-80 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 2.375" O.D.


HS-80 CM* or HS-80 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

2.375

0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.224

0.120
0.128
0.138
0.148
0.167
0.180
0.195
0.214

2.125
2.107
2.085
2.063
2.025
1.995
1.967
1.927

NOMINAL
WEIGHT
(lbs / ft)

3.011
3.215
3.462
3.706
4.122
4.445
4.742
5.159

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

70,700
75,500
81,300
87,000
96,800
104,300
111,300
121,100

77,800
83,000
89,400
95,700
106,400
114,800
122,400
133,200

7,200
7,700
8,300
8,900
10,000
10,800
11,600
12,700

8,000
8,600
9,200
9,900
11,100
12,000
12,900
14,100

HS-80 CM* or HS-80 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

GALLONS

BARRELS

2.375

0.120
0.128
0.138
0.148
0.167
0.180
0.195
0.214

0.850
0.904
0.970
1.035
1.158
1.241
1.335
1.453

3.580
3.527
3.460
3.395
3.272
3.189
3.095
2.977

3,511
3,707
3,945
4,177
4,600
4,876
5,181
5,548

3,691
3,909
4,178
4,442
4,929
5,252
5,614
6,058

184.24
181.13
177.37
173.64
167.31
162.38
157.86
151.50

4.39
4.31
4.22
4.13
3.98
3.87
3.76
3.61

230.14
230.14
230.14
230.14
230.14
230.14
230.14
230.14

5.48
5.48
5.48
5.48
5.48
5.48
5.48
5.48

* Continuously milled tubing.


** Butt-welded tube sections.

HS-80 CM or HS-80 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 2.625" O.D.


HS-80 CM* or HS-80 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

2.625

0.134
0.145
0.156
0.175
0.190
0.204
0.224
0.250

0.128
0.138
0.148
0.167
0.180
0.195
0.214
0.240

2.357
2.335
2.313
2.275
2.245
2.217
2.177
2.125

NOMINAL
WEIGHT
(lbs / ft)

3.574
3.850
4.124
4.590
4.953
5.288
5.758
6.357

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

83,900
90,400
96,800
107,800
116,300
124,100
135,200
149,200

92,300
99,400
106,500
118,500
127,900
136,500
148,700
164,100

7,000
7,500
8,100
9,100
9,800
10,500
11,500
12,900

7,800
8,400
8,900
10,100
10,800
11,700
12,800
14,300

HS-80 CM* or HS-80 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

GALLONS

BARRELS

2.625

0.128
0.138
0.148
0.167
0.180
0.195
0.214
0.240

1.004
1.078
1.152
1.290
1.383
1.489
1.621
1.798

4.408
4.334
4.260
4.122
4.029
3.923
3.791
3.614

4,599
4,901
5,196
5,735
6,089
6,482
6,958
7,571

4,826
5,163
5,493
6,106
6,514
6,972
7,536
8,277

226.66
222.45
218.28
211.17
205.63
200.54
193.36
184.24

5.40
5.30
5.20
5.03
4.90
4.77
4.60
4.39

281.14
281.14
281.14
281.14
281.14
281.14
281.14
281.14

6.69
6.69
6.69
6.69
6.69
6.69
6.69
6.69

* Continuously milled tubing.


** Butt-welded tube sections.

HS-80 CM or HS-80 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 2.875" O.D.


HS-80 CM* or HS-80 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

2.875

0.156
0.175
0.190
0.204
0.224
0.250
0.280

0.148
0.167
0.180
0.195
0.214
0.240
0.270

2.563
2.525
2.495
2.467
2.427
2.375
2.315

NOMINAL
WEIGHT
(lbs / ft)

4.541
5.059
5.462
5.834
6.358
7.026
7.779

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

106,600
118,800
128,200
136,900
149,200
164,900
182,600

117,300
130,600
141,000
150,600
164,200
181,400
200,900

7,400
8,300
8,900
9,700
10,600
11,800
13,200

8,200
9,200
9,900
10,700
11,700
13,100
14,700

HS-80 CM* or HS-80 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

GALLONS

BARRELS

2.875

0.148
0.167
0.180
0.195
0.214
0.240
0.270

1.268
1.421
1.524
1.642
1.789
1.987
2.210

5.224
5.071
4.968
4.850
4.703
4.505
4.282

6,326
6,996
7,438
7,930
8,529
9,305
10,139

6,657
7,409
7,911
8,478
9,176
10,097
11,111

268.01
260.12
253.98
248.31
240.32
230.14
218.66

6.38
6.19
6.05
5.91
5.72
5.48
5.21

337.24
337.24
337.24
337.24
337.24
337.24
337.24

8.03
8.03
8.03
8.03
8.03
8.03
8.03

* Continuously milled tubing.


** Butt-welded tube sections.

HS-80 CM or HS-80 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new tubing at specified minimum
strengths.

Coiled Tubing Data 3.5" O.D.


HS-80 CM* or HS-80 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

3.500

0.175
0.190
0.204
0.224
0.250
0.280

0.167
0.180
0.195
0.214
0.240
0.270

3.150
3.120
3.092
3.052
3.000
2.940

NOMINAL
WEIGHT
(lbs / ft)

6.230
6.733
7.199
7.857
8.699
9.653

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

146,200
158,100
169,000
184,400
204,200
226,600

160,900
173,900
185,900
202,900
224,600
249,300

6,800
7,400
8,000
8,700
9,800
10,900

7,600
8,200
8,800
9,700
10,800
12,200

HS-80 CM* or HS-80 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

GALLONS

BARRELS

3.500

0.167
0.180
0.195
0.214
0.240
0.270

1.749
1.877
2.025
2.209
2.458
2.740

7.872
7.744
7.596
7.412
7.163
6.881

10,702
11,405
12,195
13,164
14,433
15,817

11,219
12,000
12,885
13,982
15,440
17,060

404.84
397.16
390.07
380.04
367.20
352.66

9.64
9.46
9.29
9.05
8.74
8.40

499.80
499.80
499.80
499.80
499.80
499.80

11.90
11.90
11.90
11.90
11.90
11.90

* Continuously milled tubing.


** Butt-welded tube sections.

HS-80 CM or HS-80 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

You might also like