Datasheet for HSD Closed Drain Vessel Immersion Heater

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 Tag No. : Service: P & ID No. : Calculation Ref. : No. of Units: TWO (2) UNITS 02H-6010 A/B Closed Drain Vessel HSD-A-TS-F-DW-0201-00 Client: Plant Location: Manufacturer: Purchase Order No. : THANG LONG JOINT OPERATING COMPANY Offshore Vietnam (HSD WHP) TBA

Line No. : Service Description:


Immersion Heater for Closed Drain Vessel

ELECTRICAL DESIGN BASIC DESIGN Heater Size Capacity Protection Type IP Explosion Protection E Ex ELECTRICAL DATA Electrical Rating Watt Density Nominal Current Inrush Current Recommended Fuse/CB kW W/m2 Amps Amps Amps 12 (VTC) VTA VTA VTA VTA kW VTA 12 (VTC) IP66 EEx 'e' GENERAL ELECTRICAL DATA Electrical Supply System Voltage Phase Frequency Prospective Fault Level Temperature Control ELECTRICAL CONNECTIONS & MISCELLANEOUS Feeder Cable Type Feeder Cable No./Size Gland Type Entry/Size Main Terminal Box Ex Type/Material VTA mm mm mm VTA VTA VTA Incoloy 800 Two (2) 6"(Note 9) 150# SA-105N mm VTA (Note 10) Instrument Junction Box Ex Type/Material External Earth Terminal for Terminal Box Dimensions of Main Terminal Box Dimensions of Instrument Junction Box 0.6/1 kV Cu/EPR/GSWB/EVA TBA TBA EX'd'/SS316L EX'e'/SS316L YES VTA VTA Hz kA Volt 400 3 50 10 Yes

CONSTRUCTION DATA Number of Elements Bundle Diameter Max. Immersion Length Unheated Length Heater Tube Material No. of Heaters Heater FlangeA/essel Nozzle Size Heater Flange Rating Flange Material Maximum Heater Length Insulating material of the resistance wire Heater element material heating element secured to flange Sun cover over main terminal box Over temperature devices Main terminal box space heater included

Compacted magnesium oxide powder 80/20 NiCr Yes VTA Yes VTA

A01
Rev.

15/10/2011
Date

ISSUED FOR IDC


Issue Description

GO
Originated

JL
Checked

VR
Approved PTSC APPV TLJOC APPV

THANG LONG JOINT OPERATING COMPANY


HST FULL FIELD & HSD EARLY PRODUCTION SYSTEM DEVELOPMENT

Project No: Datasheet No:

11010 HSD-A-TS-M-DS-0010

SHEET 1 OF 2

Datasheet for HSD Closed Drain Vessel Immersion Heater


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 Tag No. : Service: P & ID No. : Calculation Ref. : No. of Units: TWO (2) UNITS 02H-6010 A/B Closed Drain Vessel HSD-A-TS-F-DW-0201-00 Client: Plant Location: Manufacturer: Purchase Order No. : THANG LONG JOINT OPERATING COMPANY Offshore Vietnam (HSD WHP)

TBA

Line No. : Service Description:


Immersion Heater for Closed Drain Vessel

NOTES 1 2 3 4 5 6 7 Refer to document no.GEN-A-TS-M-SP-0003, Specification for Electric Heaters for additional informaton. Heater element shall be of withdrawable type. Terminals for all heater elements shall be provided. Separate junction boxes (externally mounted) shall be provided for different type of signals Other temperature control for process requirement in the vessel heating shall be provided by OTHER and not included this Immersion Heater scope of supply. A minimum of 10% spare heater elements shall be provided. For heater over temperature protection, RTD (DIN PT 100) type temperature sensor shall be used.Temperature element wiring shall be connected to skid mounted "SMART" type ( HART) temperature transmitters with 4-20mA output signals to interface to purchaser's 'Safety Shutdown System' Transmitters shall be IS type EEx "i", certified for Zone 1 ,Gas Group IIA/IIB, T3 in accordance with ATEX Directive. Spare temperature sensor shall be provided & shall be wired to skid mounted JB (EEx "e" type). 8 9 Main terminal box shall be provided with ON/OFF indication lamp. Refer to document no.HSD-A-TS-M-DS-0011,Vendor to confirm the heater mounting flange size.

10 Refer to document no.HSD-A-TS-M-DS-0011, Data Sheet for Closed Drain Vessel. Immersion Heater length to be specified in Vendor's quotation 11 Bolting and gaskets required for the heater assembly to vessel to be provided by the heater vendor. For material of bolting and gasket, Refer to Closed Drain Vessel datasheet 12 Immersion Heater shall be self supporting without additional support inside the vessel. Vendor shall advise Purchaser if this is not possible. 13 VTA = Vendor To Advise, VTC = Vendor To Confirm, TBA = To Be Advise.

THANG LONG JOINT OPERATING COMPANY


HST FULL FIELD & HSD EARLY PRODUCTION SYSTEM DEVELOPMENT

Project No: Datasheet No:

11010 HSD-A-TS-M-DS-0010

SHEET 2 OF 2