Professional Documents
Culture Documents
1a
QCFLevel3NVQDiplomainDomesticPlumbing andHeating;or QCFLevel3NVQDiplomainDomesticHeating;or Level3SVQinPlumbing QCFunitofachievementofunit(s): M/502/9156Understandandapplydomestic centralheatingsysteminstallation,commissioning, serviceandmaintenancetechniques;or SCQFunitofachievementofunit(s): F9H604InstallandCommissionCentralHeating Systems NVQLevel3inPlumbingordomesticheatingor AdvancedcraftCertificateinPlumbingordomestic heating Alternativecertificationthathasbeenmappedto thecompetencerequirementswithinthisAnnex andagreedbySummitSkillsasaligningwiththe competencerequirementswithinthisannexand aligningwiththerelatedrequirementsfor acceptanceasalternativecertification RegisteredwithaBuildingRegulationsCompetent PersonSchemeorcertificatedbyanotheraUKAS AccreditedCertificationBodyforthetypeofwork coveredinthisannex
1b
Yes
No
1c 2
No
Yes
Qualificationsotherthanaboveornoformal Qualification
Yes
Yes
WetHeatingSystemsInstallationWork(Domestic) Context/Scope
Knowthesourcesofinformationrequiredwhenundertakingworkon wetheatingsystems: statutoryregulations industrystandards manufacturertechnicalinstructions Knowthenotificationrequirementsforworkonwetheatingsystem: waterundertaker buildingcontrolorselfcertification Statethepurposeofcentralheatingsystemsusedindwellings Identifythedifferenttypesofspaceheatingsystemsusedindwellings: fullcentralheating backgroundheating selectiveheating twoandonepipesystems Identifytheworkingprinciplesofcentralheatingsystems: pumpedheatingonlysystem pumpedwithgravityhotwater fullypumpedwith2xtwoportvalves fullypumpedwithamidpositionvalve combinationboilerwithpumpedheating
Knowtheusesofcentralheatingsystemsin dwellings
Knowthetypesofcentralheatingsystemand theirlayoutrequirements
WetHeatingSystemsInstallationWork(Domestic) Context/Scope
Knowthetypeofcentralheatingsystem: openvented - pumpedheatingonly - pumpedwithgravityhotwaterincludingheatsink circuits - fullypumpedwith2xtwoportvalves - fullypumpedwithamidpositionvalve Sealedsystem - pumpedheatingonly - fullypumpedwith2xtwoportvalves - fullypumpedwithamidpositionvalve - combinationboilerwithpumpedheating - systemboilerwithpumpedheating Knowthesystemlayoutfeaturesforfillingandventingsystems: openventedsystems - feedandexpansioncisternposition - pumpposition - coldfeedandopenventpipeconnection - methodsofreleasingairfromthesystem sealedsystems - expansionvesselposition - pressuregauge,pressurereliefvalveandfillingloop position - pumpposition - methodsofreleasingairfromthesystem Knowthelayoutfeaturesforsystemsthatincludemicroandminibore pipework Knowthegeneraloperatingprinciplesofsolidfuelheatproducing appliances:
Knowthetypesofcentralheatingsystemand theirlayoutrequirements(continued)
Thisrequirementisspecifictothe schemerelatingtotheinstallationofa
WetHeatingSystemsInstallationWork(Domestic) Context/Scope
Knowthegeneraloperatingprinciplesofoilfiredheatproducing appliances: pressurejet - traditionalboilers - condensingboilers - combinationboilers - freestandingboilers - wallmountedboilers - openfluedboilers - roomsealedboiler vapourising - openfluedcookers Knowthegeneraloperatingprinciplesofgasfiredheatproducing appliances: openfluedboilers roomsealedboilers traditionalboilers condensingboilers combinationboilers systemboilers freestandingboilers wallmountedboilers fanassistedboilers Knowtheoperatingprinciplesofheatemitters: panelradiators columnradiators lowsurfacetemperatureradiators fanconvectors
Knowthetypesofcentralheatingsystemand theirlayoutrequirements(continued)
WetHeatingSystemsInstallationWork(Domestic) Context/Scope
Knowthefunctionandoperatingprinciplesofcentralheating componentsandcontrols: radiatorvalvesthermostaticandmanualvalves automaticairvents motorisedvalvestwoportandthreeportmidpositionand diverter hotwaterstoragecylinders feedandexpansioncisterns circulatingpumps automaticbypassvalves thermomechanicalcylindercontrolvalves antigravityvalves drainvalves timingdevicesclocksandprogrammers roomthermostats cylinderthermostatsandoverheatprotectiondevices frostandpipecombinedthermostats othercontrols - weathercompensation - delayedstart - optimumstart - homeautomationsystems Knowtheoperatingprinciplesofdevicesusedincentralheating systemstominimisethebuildupofsediment Knowthesystemlayoutfeaturesformultipleboilerinstallations incorporatinglowlossheaders
Knowthetypesofcentralheatingsystemand theirlayoutrequirements(continued)
WetHeatingSystemsInstallationWork(Domestic) Context/Scope
Knowhowtoanalyseandinterpretfunctionalflowwiringdiagramsto determinethemethodofcontroloperationforcentralheating systems: pumpedheatingonlysystems pumpedheatingsystemswithcombinationboilers pumpedheatingwithgravityhotwatersystems fullypumpedincorporating3portvalvesmidpositionanddiverter valves fullypumpedincorporating2xtwoportvalves fullypumpedincorporatinghotwaterandmultiplespaceheating zones fullypumpedincorporatingweathercompensation,optimumstart ordelayedstartcontrollers multipleboilercontrolsapplication applicationoffrostthermostatsandboilerswithpumpoverrun facility pipeworkmaterials pipeworkfittingsandfixings
Knowthetypesofwetcentralheatingsystem andtheirlayoutrequirements(continued)
Beabletomakepipeworkfixingstocopperandlowcarbonsteel centralheatingsystempipework
M7, Kn.j M7, Pf.2,9 SUMMES 10, Kn.b SUMMES 10, Pf.2 SUMMES 10, Pf.4
WetHeatingSystemsInstallationWork(Domestic) Context/Scope
Knowthepositioningandfixingrequirementsofcomponentsincentral heatingsystems: radiatorvalvesthermostaticandmanualvalves automaticairvents motorisedvalvestwoportandthreeportmidpositionand diverter hotwaterstoragecylinders feedandexpansioncisterns circulatingpumps automaticbypassvalves thermomechanicalcylindercontrolvalves antigravityvalves drainvalves timingdevicesclocksandprogrammers roomthermostats cylinderthermostatsandoverheatprotectiondevices frostandpipecombinedthermostats Knowsuitablemethodsandhowtoposition,fixandconnectnew centralheatingpipeworktocomponentsandbeabletoposition,fix andconnectnewcentralheatingpipeworktocomponents boilers centralheatingcontrolsystemcomponents heatemitters hotwaterstoragecylinders feedandexpansioncisterns fillingandventingcomponents Knowsuitablemethodsformakingnewcentralheatingpipework connectionsintoexistingcentralheatingcircuits: toaonesystem
SUMMES10, K2
SUMMES10, K4
WetHeatingSystemsInstallationWork(Domestic) Context/Scope
Beabletoensurethatcentralheatingcomponentsandpipework systemscannotbebroughtintooperationbytheenduserbeforethe workhasbeenfullycompleted Knowthecheckstobecarriedoutduringavisualinspectionofa centralheatingsystemtoconfirmthatitisreadytobefilledwithwater andbeabletocarryoutavisualinspectionofacentralheatingsystem toconfirmthatitisreadytobefilledwithwater: openventedsystems sealedsystems Knowhowtofillcentralheatingsystemswithwateratnormal operatingpressureandcheckforleakageandbeabletofillcentral heatingsystemswithwateratnormaloperatingpressureandcheckfor leakage: openventedsystems sealedsystems Knowhowtocarryoutasoundnesstesttoindustryrequirementson centralheatingsystemspipeworkandcomponentsandbeableto performasoundnesstesttoindustryrequirementsoncentralheating systemspipeworkandcomponents metallicpipeworksystems plasticpipeworksystems Knowtheactionsthatmustbetakenwheninspectionandtesting
SUMMES10, P9 SUMMES25, K1 SUMMES25, P1,P2 SUMMES25, K2 SUMMES25, P2,P4 SUMMES25, K1 SUMMES25, P3,P4 SUMMES25,
K4
WetHeatingSystemsInstallationWork(Domestic) Context/Scope
Knowtheflushingrequirementsincludingtheuseofchemical treatmentsfornewandexistingcentralheatingsystems: coldandhotflushing powerflushing Knowtheinformationsourcesandbeabletointerprettheinformation sourcesrequiredtocompletecommissioningworkoncentralheating systems Knowthechemicaltreatmentrequirementsfornewandexisting centralheatingsystemsandbeabletotreatacentralheatingsystem withappropriateadditives: systemadditives - neutralisers - cleansers - corrosioninhibitors Knowthemethodrequiredtobalanceacentralheatingsystemduring commissioningactivitiesandbeabletobalanceacentralheating systemtomeetdesignrequirements
Annex10a NOSRef.
SUMMES27, K3 SUMMES25, P1,P2 SUMMES27, K1
FurtherGuidance
WetHeatingSystemsInstallationWork(Domestic) Context/Scope
Beabletoadjustsystemcontrolstoestablishthatthesystemoperates toitsdesignspecifications Knowtherangeofinformationthatwouldbedetailedona commissioningrecordforacentralheatingsystemandbeableto preparecommissioningrecordsforcompletedsystems Knowtheprocedurefornotifyingworkscarriedouttotherelevant authority
Annex10a NOSRef.
SUMMES27, P3 SUMMES27, K6 SUMMES27, P1 SUMMES27, K6 SUMMES27, K7 SUMMES27, P5
FurtherGuidance
SUMMES27, K8
WetHeatingSystemsInstallationWork(Domestic) Context/Scope
Knowtheworkingmethodsthatreducetheperiodsduringwhich centralheatingsystemsarenotavailabletobuildingusers
Annex10a NOSRef.
SUMMES13, K1,K3 SUMMES13, K2 SUMMES13, P1 SUMMES13, K4 SUMMES13, P3 SUMMES13, K4 SUMMES13, K6 SUMMES13, K5 SUMMES13, P4
FurtherGuidance
Knowtheinformationthatneedstobeprovidedtootherpersons beforedecommissioningworktakesplaceandbeabletoadvise appropriatepersonsbeforecentralheatingcomponentsorpipework areisolatedinordertoundertakework Knowhowtotemporarilydecommissioncentralheatingand connectingpipeworksystemsandbeabletocarryouttemporary decommissioningofcentralheatingsystemcomponentsand connectingpipeworksystems Knowtheworksequencesforpermanentlydecommissioningcentral heatingandpipeworksystems Knowtheproceduresforsafelydraininganddisposingofcentral heatingsystemcontents Knowthemethodsusedandbeabletoapplythemethodsusedduring thedecommissioningprocesstopreventtheenduserfromoperating theapplianceorsystem: isolationofthefuel/electricitysupplytothesystem temporarycappingofpipeworksections useofwarningnoticesandsigns
WetHeatingSystemsInstallationWork(Domestic) Context/Scope
Knowthefactorswhichaffecttheselectionofcentralheatingsystems fordwellings Knowthecriteriausedwhenselectingheatingsystemandcomponent types: customersneeds buildinglayoutandfeatures suitabilityofsystem energyefficiency environmentalimpact Knowrelevantinformationsourcesandbeabletouserelevant informationsourceswhenundertakingdesignworkoncentralheating systems: statutoryregulations industrystandards manufacturertechnicalinstructions verbalandwrittenfeedbackfromthecustomer Knowhowtotakemeasurementsofbuildingfeaturesinordertocarry outdesigncalculations: fromplans,drawingsandspecifications fromsite Beabletoobtaindetailsofthecustomerjobrequirement: byfacetofacesitevisit bytakingdetailsfromplans,drawingsandspecifications Beabletodiscussandagreeinitialsystemandcomponentoptionswith thecustomer
Annex10a NOSRef.
SUMMES8, K4 SUMMES8, K1,K2,K5
FurtherGuidance
Knowthedesigntechniquesforwetcentral heatingsystems
SUMMES8, K3 SUMMES8, P3
SUMMES8, K3
WetHeatingSystemsInstallationWork(Domestic) Context/Scope
Knowappropriateoptionsfortheselectionofsystemandcontroltypes forsinglefamilydwellings Knowtheprinciplesofheatlossandgainindwellings: throughthebuildingfabric duetoventilation Knowhowtoevaluatetheheatingrequirementsofroomsindwellings whendesigningacentralheatingsystem: roomsize temperaturerequiredindoortooutdoor airchangerate Knowtheselectioncriteriaforboilersindwellingsinrelationto: spaceheatingload hotwaterheatingload heatlossfrompipework factorsforintermittentheating Knowthemethodsofcalculatingpipeworksizesandcomponentsizes forwetcentralheatingsystemsandbeabletocalculatepipework sizesandcomponentsizesforwetcentralheatingsystems: pipesizingcalculationsspaceheatingandhotwatercircuits circulatorpumpsizingcalculations heatemittersizecalculations hotwaterheatingloadcalculations boilersizecalculations expansionvesselssizecalculations(sealedcentralheatingsystems) feedandexpansioncisternsizecalculations(openventedsystems)
Annex10a NOSRef.
SUMMES8, K3 SUMMES8, K2 SUMMES8, K4
FurtherGuidance
Knowthedesigntechniquesforwetcentral heatingsystems(continued)
SUMMES8, K4
WetHeatingSystemsInstallationWork(Domestic) Context/Scope
Knowhowtospecifythepositioning,fixingandconnection requirementsofnewcentralheatingcomponentsforsealedcentral heatingsystems: connectionstoaboiler multipleboilerinstallationswithlowlossheaders fullypumpedcentralheatingcontrolcomponentsmidpositionor 2xtwoportvalvearrangement sealedsystemcomponents connectionstopanelradiators connectionstohotwatercylinder Knowhowtopresentandbeabletopresentdesigncalculationsinan acceptableformat: usingbasicnottoscalelinedrawings detailsforinsertionintoaquotationortenderforworkinasmall scaledwelling
Knowthedesigntechniquesforwetcentral heatingsystems(continued)
SUMMES8, K2,K3