You are on page 1of 60

MACLEAN POWER SYSTEMS

Rev: A2 Date: 07/2004

Insulator Products
Table of Contents
Section Page Numbers

Products

General Information
Under Revision

Application Guide
Under Revision

Distribution Insulators
Deadend Insulators Line Post Insulators Station Post Insulators DDE DLP SP100 DDE-1 DLP-1 SP100-1 to to to DDE-3 DLP-7 SP100-4

Transmission Insulators
Suspension Insulators Line Post Insulators Station Post Insulators Braced Post Insulators Hardware Assemblies SI LP SP200 BP HA SI-1 LP-1 SP200-1 BP-1 to to to to to SI-13 LP-14 SP200-6 BP-10

Insulator Index - Page: 1 of 3


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2 Date: 07/2004

Insulator Products
Insulator Index
Voltages Section Page Numbers

Insulator Type

Distribution Deadends
DDE Information DS-M Series Insulators DS-G Series "FiberLink"
15kV - 28kV 15kV - 35kV

DDE
DDE-1 DDE-2 DDE-3

Distribution Line Posts


DLP Information 1.5" Line Posts LPC Series Insulators LPCV Series Insulators 1.75" Line Posts OLPK Series Insulators OLPV Series Insulators Tie-Top / F-Neck Insulators

DLP
DLP-1 -2
15kV - 35kV 15kV - 35kV

DLP-3 DLP-4 DLP-5 DLP-6 DLP-7

44kV - 88kV 44kV - 88kV 15kV - 69kV

Distribution Station Posts


Station Post Information Standard Strength Insulators (1.75" Rod) High Strength Insulators (2.5" Rod)
7.5kV - 69kV 23kV - 69kV

SP100
SP100-1 -2 SP100-3 SP100-4

Suspension Insulators
Suspension Information S1 Series Insulators - 25k SML (16mm Rod) S5 Series Insulators - 30k SML (18mm Rod) S6 Series Insulators - 36k SML (18mm Rod) S2 Series Insulators - 50k SML (24mm Rod) S4 Series Insulators - 80k SML (32mm Rod)
69kV - 500kV 69kV - 500kV 69kV - 500kV 115kV - 500kV 230kV - 500kV

SI
SI-1 -3 SI-4 -5 SI-6 -7 SI-8 -9 SI-10 -11 SI-12 -13

Line Post Insulators


Line Post Information H1 Series Insulators (2.0" Rod) H1C1 - Drop Tongue / Fixed Base H1C2 - Trunnion / Fixed Base H191 - Drop Tongue / Bendable Base

LP
LP-1 -5
69kV - 161kV 69kV - 161kV 69kV - 161kV

LP-6 LP-7 LP-8

Insulator Index - Page: 2 of 3


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2 Date: 07/2004

Insulator Products
Voltages

Insulator Type

Section

Page Numbers

Line Post Insulators - (continued)


H2 Series Insulators (2.5" Rod) NPKG - Trunnion / Fixed Base NBKG - Trunnion / Bendable Base NBSG - Drop Tongue / Bendable Base H291 - Drop Tongue / Bendable Base H3 Series Insulators (3.0" Rod) H391 - Drop Tongue / Bendable Base H3A Series Insulators (3.5" Rod) H391 - Drop Tongue / Bendable Base
69kV - 230kV 69kV - 230kV 69kV - 230kV 230kV - 345kV

LP
LP-9 LP-10 LP-11 LP-12 LP-13 LP-14

115kV - 345kV

115kV - 161kV

Station Post Insulators


Station Post Information Standard Strength (2.5" Rod) High Strength (3.5" Rod)
69kV - 315kV 69kV - 500kV

SP200
SP200-1 -3 SP100-4 SP100-5 -6

Braced Post Insulators


Braced Post Information Standard Strength - 2.5" Braced Posts B291 Series - Bendable Base Design B261 Series - Swivel Base Design Braced Post Request Worksheet

BP
BP-1 -5
69kV - 230kV 69kV - 161kV

BP-6 -7 BP-8 -9 BP-10

Hardware Assemblies
Under Revision

HA

Insulator Index - Page: 3 of 3


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Distribution Deadend Insulators

MPS Distribution Deadend Insulator Differentiation


CR E-Glass Core MPS uses Boron Free Corrosion Resistant E-Glass on all its insulators for its high
electrical Integrity & high resistance to acid corrosion. The boron free formulation of the fiberglass core makes it resistant to nitric acid attacks. CR E-Glass allows MPS to claim a truly

BRITTLE FRACTURE FREE INSULATORS. Silicone Rubber MPS uses a Silicone formulation that is unchanged since the early 80s.
The Si-O molecular bonds (inorganic backbone of Silicone) are very stable and have bond strengths higher than sunlight, making the silicone resistant to UV degradation. In addition to providing protection against ultraviolet radiation, electrical aging, and corona effect, silicone exhibits hydrophobic properties; which provide excellent recovery characteristics to control leakage currents in highly polluted or coastal environments. MPS silicone rubber formulation has consistently outperformed other silicone formulations in its hydrophobicity, its hydrophobicity recovery rate, and enhanced electrical properties in contaminated environments.

DS-M Series Distribution Deadends


Conventional design deadend insulator Silicone shed housing is injection molded onto and bonded to the CR rod core. Ductile iron end fittings are crimped to the fiberglass core in a tightly controlled process that ensures predictable tensile strength. Unique multi level sealing process.

FIBERLINK Distribution Deadends


Wound Fiberglass Core and metal eyelets make up the basic structure of this new and unique insulator. Silicone rubber is molded onto the wound core. The lack of metal end fittings result in a greater dry arc distance, which increases electrical performance. Light weight insulator.

Distribution Deadend Insulators Page DDE-1 of DDE-3


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Distribution Deadend Insulators

DS-M Series
15kV 28kV

Typical Line Voltage Catalog No. kV

Section Length in [mm]

Dry Arc in [mm]

Leakage in [mm] Dry

Electrical Flashover (kV) 60 Hz Wet Pos CIFO Neg

Weight lbs. kg.

15 28
Notes:

DS-15M DS-28M

13.0 [330] 17.0 [430]

7.6 [192] 11.6 [294]

15.8 [401] 24.7 [628]

90 130

65 100

140 190

145 220

2.6 2.9

1.18 1.32

SML = 15,000 lbs [66.7 kN] RTL = 7,500 lbs [33.4 kN] All ratings meet or exceed the requirements of ANSI C29.13 (2000) and LWIWG-01 (96) Corrosion Resistant Fiberglass Core / Silicone Housing RUS Accepted

Distribution Deadend Insulators Page DDE-2 of DDE-3


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Distribution Deadend Insulators

FIBERLINK
15kV 35kV

Metal Eyelets
G Galvanized S Stainless Steal (300 Series)

Typical Line Voltage Catalog No. kV

Section Length in [mm]

Leakage in [mm]

Electrical Flashover (kV) 60 Hz Dry Wet CIFO Pos Neg

Weight lbs. kg.

Quantity CTN Pallet

15 28 35

DS-15G DS-15S DS-28G DS-28S DS-35G DS-35S

12.50 [318] 17.78 [451] 22.55 [572]

15.0 [381] 26.0 [660] 34.8 [884]

133

112

202

225

1.2

.54

18

540

177

157

286

357

1.6

.73

18

486

222

199

325

401

2.0

.91

18

342

Notes: SML = 15,000 lbs [66.7 kN] RTL = 7,500 lbs [33.4 kN]

Distribution Deadend Insulators Page DDE-3 of DDE-3


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Distribution Line Post Insulators

INJECTION MOLD-OVER WEATHERSHEDS & COVERINGS


To protect the fiberglass rod, the housing is injection molded using high temperature and high pressure to bond Silicone Rubber to the surfaces of both the rod and end fittings into One Seamless Unit. By permanently protecting against rod degradation due to entry of moisture and contaminants, surface tracking and arcing of the resin rod is prevented.

Insulator Cross Section

HOUSING MATERIAL
Silicone In addition to providing protection against ultraviolet radiation, electrical aging, and corona effect, silicone exhibits hydrophobic properties. The hydrophobic properties of the silicone provide excellent recovery characteristics to control leakage currents in highly polluted or coastal environments. MPS silicone rubber formulation has consistently outperformed other silicone formulations in its hydrophobicity, its hydrophobicity recovery rate, and enhanced electrical properties in contaminated environments.

MECHANICAL STRENGTH
Maximum Design Cantilever Load (MDCL) - The maximum load that can be applied to the insulator for long periods of time, without damaging or fatiguing the insulator. Specified Cantilever Load (SCL) Maximum rating or Ultimate Strength of the insulator. Specified Tensile Load - This is the maximum tensile (transverse) rating of the insulator.

Bonded interface between rod, rubber, and metal end fitting forming impenetrable moisture barrier.

COMPRESSION END FITTINGS


All end fittings on injection molded distribution insulators are attached using a crimping process to achieve the required tensile strength. The cast iron end fittings are galvanized for protection against corrosion, and are compatible with aluminum suspension clamps and conductors on line posts.

Distribution Line Post Insulators Page DLP-1 of DLP-7


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Distribution Line Post Insulators

Catalog Number Definition Injection Molded Design

N P
ANSI Class Base

K
Line End Fitting
K = Trunnion V = Vertical Trunnion N = Tie Top

G
Base Attachment
G= Gain Base N= No Base
(Stud Mount)

10 XB 005 S
Rod Size Shed Profile Number of Sheds Material Choice

0
Corona Ring Requirement

P = Fixed

10 = 1.5 20 = 1.75

XB = Series 10 XG = Series 20

S = Silicone

0 = No Ring

For Gain Base GB-06, add a -102 suffix to the catalog number

N P K G 10 XB 0 0 5 S 0 MPS York Catalog

Number Example
No Corana Ring Silicone Rubber 5 Sheds Series 10 Insulator 1.5" Rod Diameter GB-12 Gain Base Clamp Top Fixed Base ANSI Class

To order a 5 shed, 1.5 diameter rod, Trunnion/Fixed Gain Line Post Insulator, the Catalog number would be

NPKG10XB005S0

Distribution Line Post Insulators Page DLP-2 of DLP-7


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Distribution Line Post Insulators


1.5 [38mm] Dia. Rod

LPC Series Horizontal Trunnion Insulators

LPC Insulators - Stud Mounting Type


Line Voltage
kV

MDCL
lbs [kN]

Catalog No.
Product ID No.

Section Length
in [mm]

Dry Arc Leakage


in [mm] in [mm]

Electrical Flashover (kV) 60 Hz CIFO


Dry Wet Pos Neg

Weight
lbs [kg]

Standard Box Pallet Qty Qty

15 28 35

1235 [5.5] 1235 [5.5] 1235 [5.5]

NPKN10XB003S0
[ LPC-15-SIL ]

10.9 [277] 14.9 [378] 16.9 [429]

7.2 [183] 11.2 [284] 13.2 [335]

11.3 [287] 18.8 [478] 22.4 [569]

86 122 141

66 103 122

146 208 239

193 271 309

6.2 [2.8] 7.1 [3.2] 7.6 [3.4]

3 3 3

162 108 108

NPKN10XB005S0
[ LPC-28-SIL ]

NPKN10XB006S0
[ LPC-35-SIL ]

LPC Insulators with Gain Base: for pole mounted line posts
Line Voltage
kV

MDCL
lbs [kN]

Catalog No.
Product ID No.

Section Length
in [mm]

Dry Arc Leakage Weight


in [mm] in [mm] lbs [kg]

Standard Crate Qty

15 28 35
Notes:

1235 [5.5] 1235 [5.5] 1235 [5.5]

NPKG10XB003S0
[ LPC-15-SIL-GB-12 ]

12.4 [315] 16.4 [417] 18.4 [467]

7.2 [183] 11.2 [284] 13.2 [335]

11.3 [287] 18.8 [478] 22.4 [569]

13.2 [6.0] 14.1 [6.4] 14.6 [6.6]

42 42 42

NPKG10XB005S0
[ LPC-28-SIL-GB-12 ]

NPKG10XB006S0
[ LPC-35-SIL-GB-12 ]

MDCL = Max. Design Cantilever Load To order LPC Series Insulators, contact your local MPS Sales Representative. LPC Series Insulators for use in North American Market Only.

Distribution Line Post Insulators Page DLP-3 of DLP-7


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Distribution Line Post Insulators


1.5 [38mm] Dia. Rod

LPCV Series Vertical Trunnion Insulators

Stud Mounted

Vertical Mounting Base: VB-08

LPCV Insulators - Stud Mounting Type


Line Voltage
kV

MDCL
lbs [kN]

Catalog No.
Product ID No.

Section Dry Arc Leakage Length


in [mm] in [mm] in [mm]

Electrical Flashover (kV) 60 Hz CIFO


Dry Wet Pos Neg

Weight
lbs [kg]

Standard Box Pallet Qty Qty

15 28 35

1235 [5.5] 1235 [5.5] 1235 [5.5]

NPVN10XB003S0
[ LPCV-15-SIL ]

10.9 [277] 14.9 [378] 16.9 [429]

7.2 [183] 11.2 [284] 13.2 [335]

11.3 [287] 18.8 [478] 22.4 [569]

86 122 141

66 103 122

146 208 239

193 271 309

6.1 [2.8] 7.1 [3.2] 7.7 [3.5]

6 3 3

216 162 162

NPVN10XB005S0
[ LPCV-28-SIL ]

NPVN10XB006S0
[ LPCV-35-SIL ]

LPCV Insulators with Vertical Gain Base: for pole mounted line posts
Line Voltage
kV

MDCL
lbs [kN]

Catalog No.
Product ID No.

Section Length
in [mm]

Dry Arc Leakage Weight


in [mm] in [mm] lbs [kg]

Standard Crate Qty

15 28 35
Notes:

1235 [5.5] 1235 [5.5] 1235 [5.5]

NPVG10XB003S0
[ LPCV-15-SIL-VB-08 ]

25.2 [640] 29.2 [742] 31.2 [792]

7.2 [183] 11.2 [284] 13.2 [335]

11.3 [287] 18.8 [478] 22.4 [569]

14.3 [6.5] 15.3 [6.9] 15.8 [7.2]

40 40 40

NPVG10XB005S0
[ LPCV-28-SIL-VB-08 ]

NPVG10XB006S0
[ LPCV-35-SIL-VB-08 ]

MDCL = Max. Design Cantilever Load To order LPCV Series Insulators, contact your local MPS Sales Representative. LPCV Series Insulators for use in North American Market Only.

Distribution Line Post Insulators Page DLP-4 of DLP-7


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Distribution Line Post Insulators


1.75 [45mm] Dia. Rod

OLPK Series Horizontal Trunnion Insulators

Taps
OLPK-13 = -10 OLPK-17 = 7/8-9 MLPK-21 = 7/8-9 MLPK-25 = 7/8-9

Stud Mounting Type


Line Voltage
kV

MDCL
lbs [kN]

Catalog No.
Product ID No.

Section Length
in [mm]

Dry Arc Leakage


in [mm] in [mm]

Electrical Flashover (kV) 60 Hz CIFO


Dry Wet Pos Neg

Weight
lbs [kg]

Standard Box Pallet Qty Qty

46 69 69 88

1250 [5.6] 1200 [5.3] 1200 [5.3] 921 [4.1]

NPKN20XG13S0
[ OLPK-13-SIL ]

22.0 [559] 26.0 [660] 26.0 [660] 30.0 [762]

18.3 [465] 22.3 [566] 23.0 [584] 27.0 [686]

42.3 [1074] 54.0 [1372] 59.4 [1509] 71.1 [1806]

188 224 231 268

168 203 210 245

318 381 392 455

403 472 484 550

11.3 [5.1] 13.4 [6.1] 13.7 [6.2] 15.6 [7.1]

3 3 3 3

72 72 72 72

NPKN20XG17S0
[ OLPK-17-SIL ]

NPKN20XGM21S0
[ MLPK-21-SIL ]

NPKN20XGM25S0
[ MLPK-25-SIL ]

Insulators with Gain Base: for pole mounted line posts


Line Voltage
kV

MDCL
lbs [kN]

Catalog No.
Product ID No.

Section Length
in [mm]

Dry Arc Leakage Weight


in [mm] in [mm] lbs [kg]

Standard Crate Qty

46 69 69 88
Notes:

1250 [5.6] 1100 [4.9] 1100 [4.9] 921 [4.1]

NPKG20XG13S0
[ OLPK-13-SIL-GB-12 ]

23.4 [594] 27.4 [696] 27.4 [696] 31.4 [798]

18.3 [465] 22.3 [566] 23.0 [584] 27.0 [686]

42.3 [1074] 54.0 [1372] 59.4 [1509] 71.1 [1806]

18.8 [8.5] 20.3 [9.2] 20.7 [9.4] 22.3 [10.1]

42 42 42 42

NPKG20XG17S0
[ OLPK-17-SIL-GB-12 ]

NPKG20XGM21S0
[ MLPK-21-SIL-GB-12 ]

NPKG20XGM25S0
[ MLPK-25-SIL-GB-12 ]

MDCL = Max. Design Cantilever Load To change from Trunnion to Tongue end fitting, change the K to a T [EX = OLPT-13] To order OLPK Series Insulators, contact your local MPS Sales Representative. OLPK Series Insulators for use in North American Market Only.

Distribution Line Post Insulators Page DLP-5 of DLP-7


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Distribution Line Post Insulators


1.75 [45mm] Dia. Rod

OLPV Series Vertical Trunnion Insulators


Taps
OLPV-13 = -10 OLPV-17 = 7/8-9 MLPV-21 = 7/8-9 MLPV-25 = 7/8-9

Stud Mounted

Vertical Mounting Base: VB-08

Stud Mounting Type


Line Voltage
kV

MDCL
lbs [kN]

Catalog No.
Product ID No.

Section Dry Arc Leakage Length


in [mm] in [mm] in [mm]

Electrical Flashover (kV) 60 Hz CIFO


Dry Wet Pos Neg

Weight
lbs [kg]

Standard Box Pallet Qty Qty

46 69 69 88

1250 [5.6] 1200 [5.3] 1200 [5.3] 921 [4.1]

NPVN20XG13S0
[ OLPV-13-SIL ]

22.0 [559] 26.0 [660] 26.0 [660] 30.0 [762]

18.3 [465] 22.3 [566] 23.0 [584] 27.0 [686]

42.3 [1074] 54.0 [1372] 59.4 [1509] 71.1 [1806]

188 224 231 267

168 203 210 245

318 381 392 455

403 472 484 550

11.3 [5.1] 13.4 [6.1] 14.2 [6.4] 15.6 [7.1]

3 3 3 3

108 72 72 72

NPVN20XG17S0
[ OLPV-17-SIL ]

NPVN20XGM21S0
[ MLPV-21-SIL ]

NPVN20XGM25S0
[ MLPV-25-SIL ]

Insulators with Vertical Gain Base: for pole mounted line posts
Line Voltage
kV

MDCL
lbs [kN]

Catalog No.
Product ID No.

Section Dry Arc Leakage Weight Length


in [mm] in [mm] in [mm] lbs [kg]

Standard Crate Qty

46 69 69 88
Notes:

1250 [5.6] 1200 [5.3] 1200 [5.3] 921 [4.1]

NPVG20XG13S0
[ OLPV-13-SIL-VB-08 ]

25.2 [640] 29.2 [742] 29.2 [742] 31.2 [792]

18.3 [465] 22.3 [566] 23.0 [584] 27.0 [686]

42.3 [1074] 54.0 [1372] 59.4 [1509] 71.1 [1806]

19.6 [8.9] 21.1 [9.6] 22.3 [10.1] 23.7 [10.8]

40 40 40 40

NPVG20XG17S0
[ OLPV-17-SIL-VB-08 ]

NPVG20XGM21S0
[ MLPV-21-SIL-VB-08 ]

NPVG20XGM25S0
[ MLPV-25-SIL-VB-08 ]

MDCL = Max. Design Cantilever Load To order OLPV Series Insulators, contact your local MPS Sales Representative. OLPV Series Insulators for use in North American Market Only.

Distribution Line Post Insulators Page DLP-6 of DLP-7


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Distribution Line Post Insulators


1.75 [45mm] Dia. Rod

Tie-Top Insulator / F-Neck Design


Conductor, if bare, to be protected by a pad from direct contact to the metallic neck.

Line Voltage
kV

MDCL
lbs [kN]

Catalog No.
Product ID No.

Section Length
in [mm]

Dry Arc Leakage


in [mm] in [mm]

Electrical Flashover (kV) 60 Hz CIFO


Dry Wet Pos Neg

Weight
lbs [kg]

Standard Box Pallet Qty Qty

25
25 35

1250 [5.6] 1250 [5.6] 1250 [5.6] 1250 [5.6] 1250 [5.6]

NPNN20XG09S0 NPNN20XG11S0 NPNN20XG13S0 NPNN20XG15S0 NPNN20XG17S0

14.3 [363] 16.1 [409] 18.3 [465] 20.2 [513] 22.4 [569]

11.0 [279] 13.0 [330] 15.2 [386] 17.0 [432] 19.0 [483]

25.0 [635] 30.7 [780] 36.5 [927] 42.4 [1077] 48.2 [1224]

121 140 160 176 195

101 120 140 156 174

204 236 270 298 330

267 306 347 380 415

11.0 [5.0] 12.3 [5.6] 13.1 [5.9] 13.8 [6.3] 14.5 [6.6]

3 3 3 3 3

162 162 108 108 72

35 46 69
Notes:

MDCL = Max. Design Cantilever Load For pole mounted line posts, add VB-08 to catalog number, [EX = NPNN20XG09S0-VB-08] To order F-Neck Series Insulators, contact your local MPS Sales Representative. F-Neck Series Insulators for use in North American Market Only.

Distribution Line Post Insulators Page DLP-7 of DLP-7


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Distribution Station Posts - SP100


Silicone Rubber
The Si-O molecular bonds (inorganic backbone of Silicone) are very stable and have bond strengths higher than sunlight, making the silicone resistant to UV degradation. In addition to providing protection against ultraviolet radiation, electrical aging, and corona effect, silicone exhibits hydrophobic properties, which provide excellent recovery characteristics to control leakage currents in highly polluted or coastal environments. The MPS silicone rubber formulation has consistently outperformed other silicone formulations in its hydrophobicity, its hydrophobicity recovery rate, and enhanced electrical properties in contaminated environments.

Injection Molded
To protect the fiberglass rod, the housing is injection molded using high temperature and high pressure to bond to the surfaces of both the rod and end fittings into One Seamless Unit. By permanently protecting against rod degradation due to entry of moisture and contaminants, surface tracking and arcing of the resin rod is prevented.

Crimped End Fittings


All end fittings on injection molded distribution insulators are attached using a crimping process to achieve the required tensile strength. The cast iron and steel forged end fittings are galvanized for protection against corrosion, and are compatible with aluminum suspension clamps and conductors on line posts. This document intends to help users replace ANSI TR porcelain with Composite Station Posts The comparison with ANSI C29.9 Technical Reference No.s applies only for dimensional and electrical values. The Maximum Working Load (MWL) of the relevant TR porcelains are taken to be 40% of their cantilever rating. The Maximum Design Cantilever Load (MDCL) of the composite insulator is defined as the maximum load that can be permanently applied to the composite insulator without mechanical degradation. The Specified Mechanical Load (SML) is the cantilever load at which irreversible mechanical damage may be evident. In this document, the SML is the withstand cantilever strength of the composite insulator. The Height of the composite insulator matches exactly the height of the relevant porcelain insulator. The Deflection Values given in this document corresponds to the deflections measured at the relevant ANSI TR porcelain MWL. To evaluate deflections for other loads, the ratio of deflection / load is constant up to the MDCL.

Distribution Station Post Page: SP100-1 of SP100-4


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Distribution Station Posts - SP100


SP-100 Catalog Number Definition

N
Standards N ANSI F IEC

P
Bottom End Fitting

P
Top End Fitting

20 XG 15
Rod Diameter Profile Type # of Sheds 20 1.75 w/ 3 Bolt Circle 100 2.5 w/ 5 Bolt Circle XG 1.75 (Class 20) XH 2.5 (Class 100)

S
Rubber Housing S Silicone

See Drawings below for Definition & Details Options P, A, or D

Distribution Station Post Page: SP100-2 of SP100-4


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Distribution Station Posts - SP100


NPP20XG Series Station Posts
For Systems from

7.5kV to 69kV B.I.L.: 95kV --- 350kV


P End Fittings = 3 Bolt Circle Class 20 = 1.75 Solid Rod HTV Silicone Rubber housing Exceeds the ANSI C29.9 Electrical requirements Tensile Strength = 16,000 lbs Torsional Strength = 12,000 in-lbs

Electrical Characteristics

Mechanical Properties

Porcelain TR

Critical Impulse

Line Voltage

Wet Withstand

BIL Rating

Compression
lbs

Leakage

Withstand Max. RIV

Low Freq.

@ 1 MHz Test Voltage

Weight

CIFO +

Height

to Ground

Catalog No.

Minimum Values kV Inch Inch lbs kV kV kV V kV lbs lbs Inch

kV

7.5 15 23 34.5 46 69
Notes:

NPP20XG05S NPP20XG07S NPP20XG11S NPP20XG15S NPP20XG19S NPP20XG27S

202 205 208 210 214 216

95 110 150 200 250 350

7.5 10.0 14.0 18.0 22.0 30.0

12.7 20.5 32.2 43.9 55.6 77.0

6 7 9 10 12 17

30 45 60 80 100 145

105 125 170 225 280 390

95 110 150 200 250 350

50 50 100 100 200 200

5 10 15 22 30 44

2,000 2,000 2,000 2,000 2,000 1,500

800 800 800 800 800 600

10k 10k 10k 10k 10k 7.5k

0.1 0.1 0.2 0.7 0.8 1.5

SCL = Specified Cantilever Load MDCL = Max. Design Cantilever Load To order Distribution Station Posts, contact your local MPS Sales Representative. Station Posts for use in North American Market Only.

Distribution Station Post Page: SP100-3 of SP100-4


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

@ TR MWL

Deflection

MDCL

SCL

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Distribution Station Posts - SP100


NAA100XH Series Station Posts
For Systems from

23kV to 69kV B.I.L.: 150kV --- 350kV


HIGH STRENGTH A End Fittings = 5 Bolt Circle Class 100 = 2.5 Solid Rod HTV Silicone Rubber housing Exceeds the ANSI C29.9 Electrical requirements Tensile Strength = 17,500 lbs Torsional Strength = 32,000 in-lbs

Electrical Characteristics

Mechanical Properties

Porcelain TR

C ritical Im pulse

Line Voltage

W et W ithstand

BIL Rating

C om pression
lbs

Leakage

W ithstand M ax. R IV

Low Freq.

@ 1 MHz Test Voltage

W eight

CIFO +

H eight

to G round

Catalog No.

Minimum Values kV Inch Inch lbs kV kV kV V kV lbs lbs Inch

kV

23 34.5 46 69
Notes:

NAA100XH06S0 NAA100XH09S0 NAA100XH12S0 NAA100XH16S0


227 231 267 278

150 200 250 350

15.0 20.0 24.0 30.0

27.0 40.8 53.6 72.0

26 30 34 38

60 80 100 145

170 225 280 390

150 200 250 350

100 100 200 200

15 22 30 44

8,000 6,500 5,500 4,400

6,000 4,200 3,500 2,770

25k 25k 25k 25k

0.2 0.3 0.6 0.7

SCL = Specified Cantilever Load MDCL = Max. Design Cantilever Load To order Distribution Station Posts, contact your local MPS Sales Representative. Station Posts for use in North American Market Only.

Distribution Station Post Page: SP100-4 of SP100-4


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

@ TR M W L

Deflection

MDCL

SC L

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Suspension Insulators
The MPS Complete Solution

CR E-Glass Core MPS uses Boron Free Corrosion Resistant E-Glass on all its insulators for its High
Electrical Integrity & High Resistance to acid corrosion. The boron free formulation of the fiberglass core makes it resistant to nitric acid attacks. There has never been a brittle facture failure of a CR Eglass insulator in over 30 years of use.

Silicone Rubber MPS uses a Silicone formulation that has been unchanged since the early 80s. The SiO molecular bonds (inorganic backbone of Silicone) are very stable and have bond strengths higher than sunlight, making the silicone resistant to UV degradation. In addition to providing protection against ultraviolet radiation, electrical aging, and corona effect, silicone exhibits hydrophobic properties; which provide excellent recovery characteristics to control leakage currents in highly polluted or coastal environments.
The MPS silicone rubber formulation has consistently outperformed other silicone formulations in its hydrophobicity, its hydrophobicity recovery rate, and enhanced electrical properties in contaminated environments.

P-S-T End Fitting Seal The P-S-T sealing system is a triple seal design with built-in redundancies. Primary seal rubber sheath compressed into chamfer of end fitting. Secondary seal RTV silicone applied to core / sheath / end fitting interface. Tertiary seal final external RTV seal applied to sheath
/ end fitting interface. The P-S-T system has clearly shown its superiority to withstand moisture penetration.

Stacked Shed The MPS Stacked Shed configuration offers inherent protection against material aging in
critical areas of the sheath and resists the resultant material erosion when installed in highly contaminated environments (resistance to Water Droplet Corona). In addition, stacked shed profiles enhance the ability of the insulator to resist mechanical damage in these most critical areas during transportation and installation.

Suspension Insulators - Page SI-1 of SI-13


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Suspension Insulators
Catalog Number Definition 4 8 0 9 7 V A
TOWER LINE

01
MPS INTERNAL USE Tower Line 17 17 8 12 12 17 8 17 None None

INSULATOR TYPE
[ Specified Mechanical Load ]

END FITTING TYPE

SECTION LENGTH (Inches)

CORONA RINGS

S1 25k SML S5 30k SML S6 36k SML S2 50k SML S4 80k SML

4 Y-Clevis 5 Tongue 6 Clevis 7 Socket 8 Ball 9 Eye

ABCDE-

Tower Line None 8 None 12 None 17 8 8 12 12

FGHVX-

S 2 4 8 0 9 7 V A 0 1

MPS Catalog Number Example


MPS Identification 8" Corona Ring on the Line End Variable Leakage 97" Insulator Section Length Ball EF on Line End Y-Clevis EF on Tower End 50k SML Insulator

To order a 97 50k SML Y-Clevis / Ball Insulator with an 8 Corona Ring, the Catalog number would be

S248097VA01

SUSPENSION INSULATORS
AVAILABLE END FITTINGS

End Fitting Type

Y-Clevis
Insulators
ANSI IEC

Tongue
ANSI IEC

Clevis
ANSI IEC

Socket
ANSI IEC

Ball
ANSI IEC

Eye
ANSI IEC

S1 S5 S6 S2 S4

25klb 120kN 30klb 36klb 160kN 30klb 50klb 210kN 80klb 300kN

*Yes *Yes *Yes *Yes *Yes *Yes

52-6 16-C 52-6 52-6 16N 52-12 22N

52-6 16-C 52-6 52-6 19-L

52-5 16 52-5 20 52-5

52-5 16 52-5 52-8 20 52-5 52-11 20/24 24 20/24

*Yes *Yes *Yes *Yes *Yes *Yes *Yes *Yes *Yes

52-10 19-C/22-L 22-L

52-11

24

* = No ANSI or IEC classification available.


Suspension Insulators - Page SI-2 of SI-13
USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Suspension Insulators

Corona Rings for Suspension Insulators


High voltages can result in unwanted noise (RIV) and corona. To minimize the effects of corona, corona rings are applied to one or both ends of the insulator (attached onto the end fittings). Typically, for system voltages 230kV and above a corona ring or combination of rings is necessary. However, some applications may require rings at lower system voltages. Refer to the Corona Ring section of the Application Guide for detailed information or contact the factory. MPS corona rings are designed around the needs of the end user. It is easy to install, unidirectional (not able to install in the wrong direction), and can be installed or removed with hot stick tools. By making the ring a one piece design, we have eliminated the problem of missing or lost parts. This was made possible by designing a unique clamping mechanism that uses one captive bolt to secure the ring to the insulator. Additionally, the clamping section was designed such that the ring can only be installed in one direction, which eliminates the problem of misapplied rings. As a final step, the ring was designed with a split (opening) to allow installation with hot stick tools.

Recommended Corona Ring Application Table


138kV Line End Tower End
None None

161kV
None None

230kV 8"
None

345kV 12"
None

400kV 12" 8"

500kV 17" 8"

Three Ring Diameters are available for use on all suspension insulator styles:

8 Ring, 12 Ring, and 17 Ring


For Insulators 230kV and above, MPS recommends use of Corona Rings. The Application Table above depicts typical corona ring usage on MPS suspension Insulators. For corona ring usage on special applications, environments, and elevations; please contact MPS.

Suspension Insulators - Page SI-3 of SI-13


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Suspension Insulators
S1 Series Insulators

Insulator Strength Ratings


SML RTL
12.5 klb 60 kN

S1

25 klb 120 kN

16mm Rod
Line Voltage
kV

"S1"

Type Catalog No.


S148040VX33 S148040VX06 S148040VX21 S148048VX24 S148048VX02 S148048VX11 S148052VX39 S148052VX36 S148052VX37 S148060VX35 S148060VX04 S148060VX36 S148064VX23 S148064VX29 S148064VX26 S148068VX14 S148068VX15 S148068VX17 S148089VX03 S148089VX04 S148089VX06 S148096VX03 S148096VX04 S148096VX06 S148104VX07 S148104VX08 S148104VX09 S148120VX01 S148120VX02 S148120VX02 S148165VX03 S148165VX04 S148165VX06

Section Length
in [mm]

Dry Arc
in [mm]

Leakage
in [mm]

Electrical Flashover (kV) CIFO 60 Hz


Dry Wet Pos Neg

Weight
lbs [kg]

69 115 115 138 161 161 230 230 230 345 500
Notes:

40.0 [1016] 48.0 [1219] 52.0 [1321] 60.0 [1524] 64.0 [1626] 68.0 [1727] 89.0 [2261] 96.0 [2438] 104.0 [2642] 120.0 [3048] 165.0 [4191]

29.9 [759] 37.9 [963] 42.9 [1090] 49.9 [1267] 53.9 [1369] 57.9 [1471] 78.9 [2004] 85.9 [2182] 93.9 [2385] 109.9 [2791] 154.9 [3934]

47.7 70.9 90.3 78.9 121.5 140.9 79.1 117.8 144.9 94.8 141.2 172.2 106.5 168.5 202.0 106.7 164.7 206.0 150.9 236.0 290.2 150.2 239.2 293.3 150.4 239.4 293.6 228.3 356.0 433.4 331.4 517.1 613.9

[1212] [1801] 299 [2294] [2004] [3086] 375 [3579] [2009] [2992] 413 [3680] [2408] [3586] 490 [4374] [2705] [4280] 528 [5131] [2710] [4183] 566 [5232] [3833] [5994] 766 [7371] [3815] [6076] 832 [7450] [3820] [6081] 909 [7457] [5799] [9042] 1039 [11008] [8418] [13134] 1368 [15593]

270

519

338

648

372

712

437

837

469

899

500

960

657

1276

707

1379

774

1496

893

1729

1143

2374

6.5 556 8.3 9.8 8.6 690 11.9 13.9 8.4 756 11.4 14.0 9.3 886 12.9 15.3 10.1 949 14.9 18.1 9.9 1013 14.4 19.3 12.5 1335 19.1 24.2 12.1 1440 19.0 23.2 11.8 1559 18.7 22.9 17.2 1795 27.1 34.5 23.3 2444 37.3 47.2

[2.9] [3.8] [4.4] [3.9] [5.4] [6.3] [3.8] [5.2] [6.4] [4.2] [5.9] [6.9] [4.6] [6.8] [8.2] [4.5] [6.5] [8.8] [5.7] [8.7] [11.0] [5.5] [8.6] [10.5] [5.4] [8.5] [10.4] [7.8] [12.3] [15.6] [10.6] [16.9] [21.4]

Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings. For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Suspension Insulators - Page SI-4 of SI-13


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Suspension Insulators
S1 Series Insulators w/ Corona Rings

Insulator Strength Ratings


SML RTL
12.5 klb 60 kN

S1

25 klb 120 kN

16mm Rod
Line Voltage

Line End 8 Ring 12Ring 17 Ring


Dry Arc
in [mm]

Tower End None None 8 Ring


Electrical Flashover (kV) 60 Hz CIFO
Dry Wet Pos Neg

230kV 345kV 500kV


Line Voltage
kV

"S1" Type
Catalog No.
S148089VA16 S148089VA19 S148089VA20 S148096VA15 S148096VA05 S148096VA03 S148104VA11 S148104VA09 S148104VA13 S148120VB07 S148120VB08 S148120VB09 S148134VG04 S148134VG05 S148134VG07 S148173VV03 S148173VV02 S148173VV01

Section Length
in [mm]

Leakage
in [mm]

Weight
lbs [kg]

230 230 230 345 400 500


Notes:

89.0 [2261] 96.0 [2438] 104.0 [2642] 120.0 [3048] 134.0 [3404] 173.0 [4394]

76.3 [1938] 83.3 [2116] 91.3 [2319] 107.3 [2725] 119.4 [3033] 157.4 [3998]

154.7 236.0 297.9 154.0 239.1 293.3 154.3 239.4 293.6 228.3 356.0 441.1 265.5 416.5 517.1 331.6 521.3 647.7

[3929] [5994] [7567] [3912] [6073] [7450] [3919] [6081] [7457] [5799] [9042] [11204] [6744] [10579] [13134] [8423] [13241] [16452]

741

638

1237

1296

808

688

1341

1401

884

754

1458

1521

1020

874

1692

1757

1108

961

1866

1933

1394

1157

2423

2494

16.7 23.0 28.8 16.4 23.0 27.2 16.1 22.7 26.9 22.0 31.9 40.9 28.2 39.9 50.6 36.0 52.2 62.5

[7.6] [10.4] [13.1] [7.4] [10.4] [12.3] [7.3] [10.3] [12.2] [10.0] [14.5] [18.6] [12.8] [18.1] [23.0] [16.3] [23.7] [28.3]

Electrical Data is with Corona Rings. For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Suspension Insulators - Page SI-5 of SI-13


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Suspension Insulators
S5 Series Insulators

Insulator Strength Ratings


SML RTL
15 klb 66.5 kN

S5

30 klb 133 kN

18mm Rod
Line Voltage
kV

"S5"

Type Catalog No.

Section Length
in [mm]

Dry Arc
in [mm]

Leakage
in [mm]

Electrical Flashover (kV) 60 Hz CIFO


Dry Wet Pos Neg

Weight
lbs [kg]

69 115 115 138 161 161 230 230 230 345 500
Notes:

S548040VX05 S548040VX07 S548040VX08 S548048VX03 S548048VX09 S548048VX10 S548052VX03 S548052VX05 S548052VX11 S548060VX03 S548060VX08 S548060VX10 S548064VX13 S548064VX14 S548064VX16 S548068VX10 S548068VX11 S548068VX12 S548089VX01 S548089VX02 S548089VX03 S548096VX03 S548096VX07 S548096VX09 S548104VX03 S548104VX06 S548104VX07 S548120VX03 S548120VX08 S548120VX10 S548165VX03 S548165VX04 S548165VX05

40.0 [1016] 48.0 [1219] 52.0 [1321] 60.0 [1524] 64.0 [1626] 68.0 [1727] 89.0 [2261] 96.0 [2438] 104.0 [2642] 120.0 [3048] 165.0 [4191]

28.0 [711] 36.0 [914] 40.0 [1016] 48.0 [1219] 52.0 [1321] 56.0 [1422] 77.0 [1956] 84.0 [2134] 92.0 [2337] 108.0 [2743] 154.5 [3924]

45.6 72.7 88.2 76.9 119.4 155.3 77.0 119.6 146.9 92.7 143.0 173.6 108.3 166.4 205.7 108.5 166.5 209.7 152.7 237.8 296.3 151.9 237.1 293.9 152.2 237.3 295.4 230.1 357.8 434.2 333.2 518.9 625.3

[1158] [1847] [2240] [1953] [3033] [3945] [1956] [3038] [3731] [2355] [3632] [4409] [2751] [4227] [5225] [2756] [4229] [5326] [3879] [6040] [7526] [3858] [6022] [7465] [3866] [6027] [7503] [5845] [9088] [11029] [8463] [13180] [15883]

281

253

488

523

357

322

617

658

395

356

681

725

471

421

807

855

509

453

869

819

547

485

931

982

747

643

1247

1306

814

693

1351

1412

890

759

1468

1531

1025

879

1701

1767

1354

1134

2346

2417

7.0 9.0 10.1 9.0 12.1 16.5 8.9 12.0 14.9 9.8 13.4 16.8 10.8 15.0 19.2 10.7 14.9 19.4 13.3 19.4 25.5 13.1 19.1 25.1 12.9 18.9 23.1 18.0 27.1 35.4 24.1 37.3 49.1

[3.2] [4.1] [4.6] [4.1] [5.5] [7.5] [4.0] [5.4] [6.8] [4.4] [6.1] [7.6] [4.9] [6.8] [8.7] [4.9] [6.8] [8.8] [6.0] [8.8] [11.6] [5.9] [8.7] [11.4] [5.9] [8.6] [10.5] [8.2] [12.3] [16.1] [10.9] [16.9] [22.3]

Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings. For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Suspension Insulators - Page SI-6 of SI-13


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Suspension Insulators
S5 Series Insulators w/ Corona Ring

Insulator Strength Ratings


SML RTL
15 klb 66.5 kN

S5

30 klb 133 kN

18mm Rod
Line Voltage

Line End 8 Ring 12Ring 17 Ring


Dry Arc
in [mm]

Tower End None None 8 Ring


Electrical Flashover (kV) 60 Hz CIFO
Dry Wet Pos Neg

230kV 345kV 500kV


Line Voltage
kV

"S5" Type
Catalog No.
S548089VA07 S548089VA10 S548089VA11 S548096VA09 S548096VA06 S548096VA10 S548104VA16 S548104VA01 S548104VA17 S548120VB17 S548120VB18 S548120VB19 S548134VG01 S548134VG02 S548134VG03 S548171VV03 S548171VV02 S548171VV01

Section Length
in [mm]

Leakage
in [mm]

Weight
lbs [kg]

230 230 230 345 400 500


Notes:

89.0 [2261] 96.0 [2438] 104.0 [2642] 120.0 [3048] 134.0 [3404] 171.0 [4343]

74.3 [1887] 81.3 [2065] 89.3 [2268] 105.3 [2675] 117.3 [2979] 154.3 [3919]

152.7 237.8 294.6 151.9 237.0 292.3 152.2 237.3 295.4 230.1 357.8 444.0 263.5 414.4 513.0 331.4 521.1 642.9

[3879] [6040] [7483] [3858] [6020] [7424] [3866] [6027] [7503] [5845] [9088] [11278] [6693] [10526] [13030] [8418] [13236] [16330]

722

624

1207

788

674

1311

865

730

1429

1005

859

1662

1093

946

1836

1364

1140

2365

16.3 1265 22.4 28.3 16.1 1371 22.1 27.9 15.9 1491 21.9 26.1 23.0 1727 32.1 43.2 28.0 1903 38.7 51.6 35.8 2436 52.5 62.2

[7.4] [10.2] [12.8] [7.3] [10.0] [12.7] [7.2] [9.9] [11.8] [10.4] [14.6] [19.6] [12.7] [17.6] [23.4] [16.2] [23.8] [28.2]

Electrical Data is with Corona Rings. For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Suspension Insulators - Page SI-7 of SI-13


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Suspension Insulators
S6 Series Insulators

Insulator Strength Ratings


SML RTL
18 klb 80 kN

S6

36 klb 160 kN

18mm Rod
Line Voltage
kV

"S6"

Type Catalog No.

Section Length
in [mm]

Dry Arc
in [mm]

Leakage
in [mm]

Electrical Flashover (kV) 60 Hz CIFO


Dry Wet Pos Neg

Weight
lbs [kg]

69 115 115 138 161 161 230 230 230 345 500
Notes:

S648040VX01 S648040VX03 S648040VX03 S648048VX03 S648048VX04 S648048VX05 S648052VX03 S648052VX04 S648052VX05 S648060VX04 S648060VX05 S648060VX06 S648064VX05 S648064VX06 S648064VX07 S648068VX02 S648068VX03 S648068VX05 S648089VX05 S648089VX06 S648089VX08 S648096VX04 S648096VX05 S648096VX07 S648104VX01 S648104VX02 S648104VX03 S648120VX01 S648120VX02 S648120VX04 S648165VX01 S648165VX02 S648165VX03

40.0 [1016] 48.0 [1219] 52.0 [1321] 60.0 [1524] 64.0 [1626] 68.0 [1727] 89.0 [2261] 96.0 [2438] 104.0 [2642] 120.0 [3048] 165.0 [4191]

28.4 [721] 36.4 [925] 40.4 [1026] 48.4 [1229] 52.4 [1331] 56.4 [1433] 77.4 [1966] 84.4 [2144] 92.4 [2347] 108.4 [2753] 153.4 [3896]

46.0 [1168] 73.1 [1857] 88.6 [2250] 77.2 [1961] 119.8 [3043] 115.7 [2939] 77.4 [1966] 119.9 [3045] 147.2 [3739] 89.2 [2266] 143.4 [3642] 174.0 [475] 108.7 [2761] 166.8 [4237] 206.1 [5235] 105.0 [2667] 166.9 [4239] 210.1 [5337] 153.1 [3889] 238.2 [6050] 296.7 [7536] 152.6 [3876] 237.7 [6038] 291.9 [7414] 152.6 [3876] 237.7 [6038] 291.9 [7414] 226.6 [5756] 358.2 [9098] 440.1 [11179] 333.5 [8471] 519.3 [13190] 625.7 [15893]

284

257

494

529

360

325

623

665

399

359

687

731

475

424

813

861

513

456

875

925

551

488

936

988

751

646

1253

1312

818

696

1356

1417

894

762

1474

1536

1028

881

1707

1772

1357

1136

2352

2422

6.9 8.8 9.9 8.9 11.9 16.3 8.8 11.8 14.7 9.4 13.2 16.6 10.7 14.8 19.0 10.3 14.7 19.2 13.1 19.2 25.4 12.9 18.9 24.9 12.7 18.7 22.6 17.5 26.9 35.7 23.9 37.1 49.0

[3.1] [4.0] [4.5] [4.0] [5.4] [7.4] [4.0] [5.4] [6.7] [4.3] [6.0] [7.5] [4.9] [6.7] [8.6] [4.7] [6.7] [8.7] [5.9] [8.7] [11.5] [5.9] [8.6] [11.3] [5.8] [8.5] [10.3] [7.9] [12.2] [16.2] [10.8] [16.8] [22.2]

Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings. For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Suspension Insulators - Page SI-8 of SI-13


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Suspension Insulators
S6 Series Insulators w/ Corona Ring

Insulator Strength Ratings


SML RTL
18 klb 80 kN

S6

36 klb 160 kN

18mm Rod
Line Voltage

Line End 8 Ring 12Ring 17 Ring

Tower End None None 8 Ring


Electrical Flashover (kV) 60 Hz CIFO
Dry Wet Pos Neg

230kV 345kV 500kV


Line Voltage
kV

"S6" Type
Catalog No.
S648089VA02 S648089VA03 S648089VA04 S648096VA01 S648096VA02 S648096VA03 S648104VA04 S648104VA10 S648104VA11 S648120VB02 S648120VB03 S648120VB04 S648134VG02 S648134VG03 S648134VG04 S648169VV03 S648169VV02 S648169VV01

Section Dry Arc Length


in [mm] in [mm]

Leakage
in [mm]

Weight
lbs [kg]

230 230 230 345 400 500


Notes:

89.0 [2261] 96.0 [2438] 104.0 [2642] 120.0 [3048] 134.0 [3404] 169.0 [4293]

74.7 [1897] 81.7 [2075] 89.7 [2278] 105.7 [2685] 117.7 [2990] 152.7 [3879]

153.1 238.2 295.0 152.3 237.5 292.7 152.6 237.7 295.8 230.5 358.2 444.4 263.8 414.8 513.4 333.7 519.5 641.3

[3889] [6050] 725 [7493] [3868] [6033] 792 [7435] [3876] [6038] 868 [7513] [5855] [9098] 1008 [11288] [6701] [10536] 1096 [13040] [8476] [13195] 1352 [16289]

626

1213

1271

677

1316

1377

732

1434

1496

862

1668

1733

949

1841

1908

1133

2342

2413

16.1 22.2 28.2 15.9 21.9 27.7 15.7 21.7 25.9 22.8 31.9 43.0 27.8 38.5 51.4 35.8 52.2 62.0

[7.3] [10.1] [12.8] [7.2] [9.9] [12.6] [7.1] [9.8] [11.7] [10.3] [14.5] [19.5] [12.6] [17.5] [23.3] [16.2] [23.7] [28.1]

Electrical Data is with Corona Rings. For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Suspension Insulators - Page SI-9 of SI-13


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Suspension Insulators
S2 Series Insulators

Insulator Strength Ratings


SML RTL
25 klb 105 kN

S2

50 klb 210 kN

24mm Rod
Line Voltage
kV

"S2"

Type Catalog No.

Section Length
in [mm]

Dry Arc
in [mm]

Leakage
in [mm]

Electrical Flashover (kV) 60 Hz CIFO


Dry Wet Pos Neg

Weight
lbs [kg]

115 138 161 161 230 230 230 345 345 345 500
Notes:

S248056VX07 S248056VX08 S248056VX09 S248062VX13 S248063VX14 S248063VX16 S248068VX07 S248068VX08 S248068VX09 S248080VX10 S248080VX02 S248080VX11 S248092VX02 S248092VX03 S248092VX05 S248097VX05 S248097VX06 S248097VX08 S248106VX01 S248106VX02 S248106VX03 S248118VX02 S248118VX03 S248118VX05 S248124VX02 S248124VX03 S248124VX05 S248130VX02 S248130VX03 S248130VX05 S248142VX06 S248142VX07 S248142VX08

56.0 [1422] 62.0 [1575] 68.0 [1727] 80.0 [2032] 92.0 [2337] 97.0 [2464] 106.0 [2692] 118.0 [2997] 124.0 [3150] 130.0 [3302] 142.0 [3607]

42.8 [1087] 48.8 [1240] 54.8 [1392] 66.8 [1697] 78.8 [2002] 83.8 [2129] 92.8 [2357] 104.8 [2662] 110.8 [2814] 116.8 [2967] 128.8 [3272]

75.9 118.0 144.9 93.4 143.2 178.6 107.1 168.3 187.5 107.6 165.0 207.2 150.2 238.3 289.6 151.4 239.5 303.6 152.7 237.0 294.4 226.0 356.2 444.7 228.2 354.7 438.6 226.5 356.7 444.6 334.3 510.6 566.9

[1928] [2997] [3680] [2372] [3637] [4536] [2720] [4275] [4763] [2733] [4191] [5263] [3815] [6053] [7356] [3846] [6083] [7711] [3879] [6020] [7478] [5740] [9047] [11295] [5796] [9009] [11140] [5753] [9060] [11293] [8491] [12969] [14399]

422

379

726

771

479

428

820

869

479

428

820

869

536

476

913

964

765

657

1275

1334

813

692

1349

1409

898

766

1481

1544

1002

855

1656

1721

1046

899

1742

1808

1090

943

1829

1896

1178

1017

2002

2070

12.5 15.9 18.0 13.9 17.9 21.1 13.9 17.9 21.1 14.9 19.5 22.8 18.2 25.2 30.0 18.3 25.3 31.1 18.3 25.0 29.6 24.1 34.4 43.4 24.2 34.3 42.0 24.0 34.4 42.5 32.5 47.8 53.5

[5.7] [7.2] [8.2] [6.3] [8.1] [9.6] [6.3] [8.1] [9.6] [6.8] [8.8] [10.3] [8.3] [11.4] [13.6] [8.3] [11.5] [14.1] [8.3] [11.3] [13.4] [10.9] [15.6] [19.7] [11.0] [15.6] [19.1] [10.9] [15.6] [19.3] [14.7] [21.7] [24.3]

Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings. For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Suspension Insulators - Page SI-10 of SI-13


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Suspension Insulators
S2 Series Insulators w/ Corona Ring

Insulator Strength Ratings


SML RTL
25 klb 105 kN

S2

50 klb 210 kN

24mm Rod
Line Voltage
kV

"S2" Type
Catalog No.
S248092VA13 S248092VA02 S248092VA14 S248097VA06 S248097VA02 S248097VA07 S248106VA07 S248106VA08 S248106VA06 S248118VB02 S248118VB03 S248118VB04 S248124VB01 S248124VB02 S248124VB03 S248134VG02 S248134VG03 S248134VG04 S248160VV04 S248160VV03 S248160VV02

Section Length
in [mm]

Dry Arc
in [mm]

Leakage
in [mm]

Electrical Flashover (kV) 60 Hz CIFO


Dry Wet Pos Neg

Weight
lbs [kg]

230 230 230 345 345 400 500


Notes:

92.0 [2337] 97.0 [2464] 106.0 [2692] 118.0 [2997] 124.0 [3150] 134.0 [3404] 160.0 [4064]

76.3 [1938] 81.3 [2065] 90.3 [2294] 102.3 [2598] 108.3 [2751] 116.4 [2957] 142.5 [3620]

154.0 238.3 297.1 151.4 239.5 296.9 152.7 237.0 294.4 229.8 356.2 442.0 228.2 358.4 442.8 265.0 414.4 514.9 333.1 517.0 644.3

[3912] 741 [6053] [7546] [3846] 789 [6083] [7541] [3879] 875 [6020] [7478] [5837] 984 [9047] [11227] [5796] [9103] 1028 [11247] [6731] [10526] 1087 [13078] [8461] [13132] 1277 [16365]

639

1238

1296

674

1312

1372

746

1444

1506

837

1619

1684

881

1706

1772

940

1823

1890

1086

2197

2267

20.6 27.3 33.1 20.4 27.4 33.1 20.4 27.1 31.7 29.0 39.1 47.7 28.9 39.2 47.7 33.8 45.7 55.8 43.4 58.0 70.9

[9.3] [12.4] [15.0] [9.3] [12.4] [15.0] [9.3] [12.3] [14.4] [13.2] [17.7] [21.6] [13.1] [17.8] [21.6] [15.3] [20.7] [25.3] [19.7] [26.3] [32.2]

Electrical Data is with Corona Rings. 230kV = 8 Ring Line End; 345kV = 12 Ring Line End;

500kV = 17 Line & 8 Ring Tower

For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Suspension Insulators - Page SI-11 of SI-13


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Suspension Insulators
S4 Series Insulators

Insulator Strength Ratings


SML RTL
40 klb 150 kN

S4

80 klb 300 kN

32mm Rod
Line Voltage
kV

"S4"

Type Catalog No.

Section Length
in [mm]

Dry Arc
in [mm]

Leakage
in [mm]

Electrical Flashover (kV) 60 Hz CIFO


Dry Wet Pos Neg

Weight
lbs [kg]

230 230 345 345 345 500 500 500 500


Notes:

S499097VX05 S499097VX06 S499097VX07 S499106VX03 S499106VX04 S499106VX05 S499118VX04 S499118VX05 S499118VX06 S499124VX06 S499124VX07 S499124VX08 S499130VX03 S499130VX04 S499130VX05 S499142VX02 S499142VX03 S499142VX05 S499152VX05 S499152VX06 S499152VX07 S499165VX10 S499165VX11 S499165VX12 S499182VX06 S499182VX07 S499182VX08

97.0 [2464] 106.0 [2692] 118.0 [2997] 124.0 [3150] 130.0 [3302] 142.0 [3607] 152.0 [3861] 165.0 [4191] 182.0 [4623]

78.7 [1999] 87.7 [2228] 99.7 [2532] 105.7 [2685] 111.7 [2837] 123.7 [3142] 133.7 [3396] 146.7 [3726] 163.7 [4158]

149.4 138.7 296.4 153.2 237.2 294.9 228.2 354.2 432.9 228.9 354.9 444.2 229.7 355.7 439.7 330.9 414.9 540.9 335.7 414.9 587.7 332.9 416.9 642.7 334.2 418.2 643.9

[3795] [3523] [7529] [3891] [6025] [7490] [5796] [8997] [10996] [5814] [9014] [11283] [5834] [9035] [11168] [8405] [10538] [13739] [8527] [10538] [14928] [8456] [10589] [16325] [8489] [10622] [16355]

764

656

1272

849

719

1405

964

817

1581

1008

862

1668

1052

906

1755

1140

989

1927

1213

1042

2071

1308

1106

2257

1432

1179

2498

30.0 1332 35.8 39.6 30.7 1467 36.2 40.0 36.3 1645 44.5 49.7 36.6 1733 44.9 50.7 37.0 1821 45.3 50.8 44.3 1995 49.8 58.1 45.2 2140 50.3 61.7 45.7 2327 51.2 66.0 46.7 2569 52.2 67.0

[13.6] [16.2] [18.0] [13.9] [16.4] [18.1] [16.5] [20.2] [22.5] [16.6] [20.4] [23.0] [16.8] [20.5] [23.0] [20.1] [22.6] [26.4] [20.5] [22.8] [28.0] [20.7] [23.2] [29.9] [21.2] [23.7] [30.4]

Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings. For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Suspension Insulators - Page SI-12 of SI-13


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Suspension Insulators
S4 Series Insulators w/ Corona Ring

Insulator Strength Ratings SML RTL


40 klb 150 kN 80 klb 300 kN

S4

32mm Rod
Line Voltage
kV

"S4" Type
Catalog No.
S499097VB02 S499097VB05 S499097VB04 S499106VB03 S499106VB06 S499106VB05 S499118VB01 S499118VB02 S499124VB05 S499124VB06 S499124VB07 S499134VG01 S499134VG02 S499165VV05 S499165VV04 S499165VV03 S499182VV03 S499182VV02 S499182VV01

Section Length
in [mm]

Dry Arc
in [mm]

Leakage
in [mm]

Electrical Flashover (kV) 60 Hz CIFO


Dry Wet Pos Neg

Weight
lbs [kg]

230 230 345 345 400 500 500


Notes:

97.0 [2464] 106.0 [2692] 118.0 [2997] 124.0 [3150] 134.0 [3404] 165.0 [4191] 182.0 [4623]

75.4 [1915] 84.4 [2144] 96.4 [2449] 102.4 [2601] 110.0 [2794] 141.0 [3581] 158.0 [4013]

152.4 236.4 294.1 150.9 240.1 292.6 225.9 357.1 226.6 357.9 441.9 262.9 415.1 335.9 519.6 645.6 331.9 520.9 641.6

[3871] [6005] [7470] [3833] [6099] [7432] [5738] [9070] [0] [5756] [9091] [11224] [6678] [10544] [0] [8532] [13198] [16398] [8430] [13231] [16297]

732

632

1223

818

696

1356

932

792

1532

35.2 1282 40.7 44.5 35.6 1417 41.4 44.9 41.2 1596 49.8 41.5 1684 50.1 55.6 47.5 1796 57.4 57.9 2245 70.0 78.2 58.6 2488 71.0 78.9

984

837

1620

1039

893

1730

1267

1079

2176

1391

1156

2417

[16.0] [18.5] [20.2] [16.1] [18.8] [20.4] [18.7] [22.6] [0.0] [18.8] [22.7] [25.2] [21.5] [26.0] [0.0] [26.3] [31.8] [35.5] [26.6] [32.2] [35.8]

Electrical Data is with Corona Rings. 230kV = 8 Ring Line End; 345kV = 12 Ring Line End;

500kV = 17 Line & 8 Ring Tower

For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Suspension Insulators - Page SI-13 of SI-13


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Horizontal Line Post Insulators

MPS offers 2 distinctive silicone line post insulator designs to comply with all the requirements of the market place. Standard designs, from 69kV to 230kV, are supplied out of the York (SC) plant using an injection molding process. These post products are manufactured to forecast in high volumes with standard lengths & leakages. Custom designs and ratings 230kV & above are produced at the Franklin Park [Reliable] (IL) plant using the extruded rod shed process, where the posts are produced to customer order, per customer specification (custom strength, length, & leakage).

York - Injection Molded Line Posts


The insulator silicone housing is injection molded, using high temperature and high pressure injection, onto the FRP rod and onto the end fittings to protect the fiberglass rod and prevent ingress of moisture. The standard leakage distances offered on these products provide were designed for use in high contamination environments. These heavy contamination designs provide between 25mm/kv to 31mm/kV leakage. Features Standard Designs / Lengths Standard Leakages [25mm/kV] Produced to Forecast Injection Molded Products 30XH Class Standard Strength Posts
2.5 Rod [NPK, NBK, NBS Series]

40XV Class High Strength Posts


3.5 Rod [NBS Series]

Reliable - Extruded Design Line Posts


The Extruded design line post insulator offers the unique ability to custom design for any application, with the flexibility to produce custom section lengths and leakage distances. Insulator section lengths can be customized to customer requirements in 1 inch increments. Variable shed count and spacing is used to provide custom leakage distances, or leakage in accordance to the IEC815 Recommendation for Polluted Areas. [Pollution Class: Low = 16mm/kV, Medium = 20mm/kV, Heavy = 25mm/kV, Very Heavy = 31mm/kV] Features Custom Designs (Variable Lengths & Leakage) Custom Leakage Distances (per IEC815) Produced to Order Extruded Seamless silicone sheath Extruded Products H1 Class Low Strength Posts
2.0 Rod [H1C1, H1C2, H191 Series]

H2 Class Standard Strength Posts


2.5 Rod [H291 Series]

H3 Class High Strength Posts


3.0 Rod [H391 Series]

Silicone Rubber MPS uses a Silicone formulation that has been unchanged since the early 80s. The Si-O molecular bonds (inorganic backbone of silicone) are very stable and have bond strengths higher than sunlight, making the silicone resistant to UV degradation. In addition to providing protection against ultraviolet radiation, electrical aging, and corona effect, silicone exhibits hydrophobic properties; which provide excellent recovery characteristics to control leakage currents in highly polluted or coastal environments. Line Post Insulators Page LP-1 of LP-14
USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Horizontal Line Post Insulators

Catalog No. Definition York Injection Molded Design

N
ANSI Class

P
Base

K
Line End Fitting
K = Trunnion S = Drop Tongue V = Vertical Trunnion

G
Base Attachment

30 XH 028 S
Rod Size Shed Profile Number of Sheds Material Choice

0
Corona Ring Requirement

P = Fixed B = Bendable

G= Gain F = Flat

30 = 2.5 40 = 3.5

XH = Series 30 XV = Series 40

S = Silicone

0 = No Ring 1 = One Ring

N P K G 30 XH 0 2 8 S 0

MPS York Catalog Number Example


No Corana Ring Silicone Rubber 28 Sheds Series 30 Insulator 2.5" Rod Diameter Gain Base Clamp Top Fixed Base ANSI Class

To order a 28 shed, 2.5 diameter rod, Trunnion/Fixed Gain Line Post Insulator, the Catalog number would be

NPKG30XH028S0

Typical End Fittings


B P S K V

Bendable Base

Fixed Base

Drop (Slotted) Tongue

Trunnion / Clamp Top

Vertical Trunnion

Line Post Insulators Page LP-2 of LP-14


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Horizontal Line Post Insulators

Catalog No. Definition- Reliable Extruded Design

H 2 9 1 0 4 0
BASE LINE

V
VARIABLE LEAKAGE

A
CORONA RINGS

00
MPS INTERNAL USE

INSULATOR TYPE

END FITTING TYPE

SECTION LENGTH (Inches)

Post Orientation H - Horizontal V - Vertical Rod Diameter 1 2.0 2 2.5 3 3.0 4 1.75

Base Type 1 2pc Flat (Steel) 3 3 Bolt Circle 4 3 Stud Base 5 5 Bolt Circle 8 No Base (Anchor only) 9 2pc Bendable Gain C 2pc Fixed Gain X - none

Line End Fitting 1 Drop Tongue 2 Horizontal Trunnion 3 3 Bolt Circle 5 5 Bolt Circle 6 Vertical Trunnion 7 F-Neck C Extended Drop Tongue D Double Trunnion X - None

Tower A - None B - None X - None

Line 6 12 None

H2 9 1 0 4 0 V A 0 0

Reliable Catalog Number Example


MPS Identification 6" Corona Ring on the Line End Variable Leakage 40" Insulator Section Length 2 Hole Drop Tongue 2 pc Gain 2.5" Rod Diameter Horizontal Post

To order a 40, 2.5 diameter rod, Drop Tongue/Bendable Gain Line Post Insulator with a 6 Corona Ring, the Catalog number would be

H291040VA00

Typical End Fittings 85-1 -2 -C

Anchor

5 Bolt Circle

Drop Tongue

Vertical Trunnion

Extended Drop Tongue

Line Post Insulators Page LP-3 of LP-14


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Horizontal Line Post Insulators

Line Post Base Options (Typical Applications)

H1 / H2 / NB_G30XH - Bendable Gain Base (Steel)

H3 (*NB_G40XV) Bendable Gain Base (Steel)

H1 / H2 / NB_F30XH - Bendable Flat Base (Steel)

H3 (**NB_F40XV) Bendable Flat Base (Steel)

* NB_G40XV Bendable Gain Base = 12 & 14 Hole Spacing ** NB_F40XV Bendable Flat Base = 10 x 15 Hole Pattern *** Additional bendable base designs / mounting patterns available, contact MPS for details ***

Bendable Base / Anchor

H1 & H2 Fixed Gain Base (Cast Ductile Iron)

Bendable Base Formed steel base that mates with an anchor end fitting of the insulator via 2 mounting bolts. Bendable
bases come in gain and flat designs, with 0 & 12 upsweep angles, as required.

Fixed Base Cast iron base that mates with a 5 bolt circle end fitting of the insulator (4 bolts). Where the bendable
designs allow for some articulation of the insulator, the fixed base does not. The fixed design comes in gain and flat designs, with a standard 12 upsweep angle.

Gain Base base design used to mate the insulator to a round pole surface. This base is attached to the pole through the
center bolt mount holes.

Flat Base base design used to mate the insulator to a flat surface, using either the 4 bolt holes along the ears of the
base, or the 2 center mount bolt holes.

Line Post Insulators Page LP-4 of LP-14


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Horizontal Line Post Insulators

Corona Rings for Line Post Insulators


High voltages can result in unwanted noise (RIV) and corona. To minimize the effects of corona, corona rings are applied to one or both ends of the insulator (attached onto the end fittings). Typically, for system voltages 230kV and above a corona ring or combination of rings is necessary. However, some applications may require rings at lower system voltages. Refer to the Corona Ring section of the Application Guide for detailed information or contact the factory.

Recommended Corona Ring Application


Class H1 & H2 30XH H3 40XV End Fitting Line End Tower End Line End Tower End 138kV
None None None None

161kV
None None None None

230kV 6"
None None None

345kV 12"
None

400kV 12" 12" 12" 12"

12"
None

For Insulators 230kV and above, MPS recommends use of Corona Rings. The Application Table above depicts typical corona ring usage on MPS suspension Insulators. For corona ring usage on special applications, environments, and elevations; please contact MPS.

For Horiz. & Vert. Trunnion Line Post Insulators


Order separately or with Post Insulators
Catalog Number
Aluminum Ductile Iron

Fig. # 1 1 1 1 1 2
Inch [mm]

Conductor Clamping Range


AWG-MCM ACSR AWG-MCM Alum.

"A"
4 - 4/0 1/0 - 477
4/0 - 795

Weight lbs [kg] ACTS 82 [37.2] 95 [43.1] 117 [53.1] 127 [57.6] 225 [102.1] 242 [109.8] FCTS 190 [86.2] 214 [97.1] 238 [108.0] 261 [118.4]

ACTS-057 ACTS-084 ACTS-106 ACTS-150 ACTS-200 ACTS-230

FCTS-057 FCTS-084 FCTS-106 FCTS-150

0.23 - 0.57 [5.8 - 14.5] 0.35 - 0.84 [8.9 - 21.3] 0.50 - 1.06 [12.7 - 26.9] 0.93 - 1.50 [23.6 - 38.1] 1.50 - 2.00 [38.1 - 50.8] 1.90 - 2.30 [48.3 - 58.4]

4 - 4/0 1 - 477 18/1


3/0 - 7155 26/7 556.5 30/7 - 1510.5 45/7 605 30/19 - 1113 45/7* 1033.5 45/7 - 1431 45/7*

In [cm] 5.25 [13.3] 5.25 [13.3] 5.25 [13.3] 5.25 [13.3] 6.50 [16.5] 8.75 [22.2]

715.5 - 1590 795 - 1192.5 1192.5 - 1510.5*

over formed armor rod 5,000 pounds ultimate longitudinal.

Line Post Insulators Page LP-5 of LP-14


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Horizontal Line Post Insulators


H1-C1 Series Insulators: [2.0 Rod Dia.]

Fixed Gain Base

Drop Tongue Fixed Gain Base


Line Voltage kV

MDCL
lbs [kN]

* Catalog No.
H1C1029VX01 H1C1029VX02 H1C1034VX01 H1C1034VX02 H1C1034VX03 H1C1040VX01 H1C1040VX02 H1C104VX03 H1C1044VX01 H1C1044VX02 H1C1044VX03 H1C1049VX01 H1C1049VX02 H1C1049VX03 H1C1054VX01 H1C1054VX02 H1C1054VX03 H1C1060VX01 H1C1060VX02 H1C1060VX03

Section Length in [mm]

Dry Arc in [mm]

Leakage in [mm] Dry

Electrical Flashover (kV)

60 Hz
Wet Pos

CIFO
Neg

Weight lbs [kg]

69 69 69 115 115 138 161


Notes:

1721 [7.7] 1401 [6.2] 1152 [5.1] 1042 [4.6] 913 [4.1] 821 [3.7] 728 [3.2]

29.0 [737] 34.0 [864] 40.0 [1016] 44.0 [1118] 49.0 [1245] 54.0 [1372] 60.0 [1524]

49.5 74.5 44.6 26.8 74.6 [681] 89.6 45.8 32.9 70.8 [836] 90.8 79.9 37.0 119.9 [940] 144.9 80.0 42.1 120.0 [1069] 150.0 95.1 47.2 145.1 [1199] 180.1 53.4 106.2 166.2 [1356] 206.2 21.7 [551]

[1257] [1892] [1133] [1895] [2276] [1163] [1798] [2306] [2029] [3045] [3680] [2032] [3048] [3810] [2416] [3686] [4575] [2697] [4221] [5237]

219

198

371

462

265

243

452

547

321

296

549

642

358

331

614

702

403

373

695

771

449

415

776

836

503

464

873

920

38.2 42.2 37.8 42.6 45.1 38.4 42.5 45.8 44.3 50.8 54.9 44.7 51.2 56.1 47.6 55.7 61.4 49.9 59.6 66.1

[17.3] [19.1] [17.1] [19.3] [20.5] [17.4] [19.3] [20.8] [20.1] [23.0] [24.9] [20.3] [23.2] [25.4] [21.6] [25.3] [27.9] [22.6] [27.0] [30.0]

STL (Specified Tensile Load) 3,500 Lbs. [15.6 kN] Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings. For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Line Post Insulators Page LP-6 of LP-14


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Horizontal Line Post Insulators


H1-C2 Series Insulators: [2.0 Rod Dia.]

Fixed Gain Base

Trunnion Fixed Gain Base


Line Voltage kV

MDCL
lbs [kN]

* Catalog No.
H1C2029VX02 H1C2029VX04 H1C2034VX03 H1C2034VX05 H1C2034VX04 H1C2040VX01 H1C2040VX02 H1C2040VX03 H1C2044VX01 H1C2044VX02 H1C2049VX03 H1C2049VX04 H1C2049VX06 H1C2054VX04 H1C2054VX05 H1C2054VX06 H1C2060VX01 H1C2060VX02 H1C2060VX03

Section Length in [mm]

Dry Arc in [mm]

Leakage in [mm] Dry

Electrical Flashover (kV)

60 Hz
Wet Pos

CIFO
Neg

Weight lbs [kg]

69 69 69 115 115 138 161


Notes:

1720 [7.7] 1400 [6.2] 1152 [5.1] 1041 [4.6] 912 [4.1] 821 [3.7] 728 [3.2]

29.0 [737] 34.0 [864] 40.0 [1016] 44.0 [1118] 49.0 [1245] 54.0 [1372] 60.0 [1524]

49.2 74.2 44.3 26.5 74.3 [673] 89.3 45.5 32.6 70.5 [828] 90.5 79.6 36.7 [932] 119.6 79.7 41.8 119.7 [1062] 149.7 94.8 46.9 144.8 [1191] 179.7 53.1 105.9 165.9 [1349] 205.9 21.4 [544]

[1250] [1885] [1125] [1887] [2268] [1156] [1791] [2299] [2022] [3038] [2024] [3040] [3802] [2408] [3678] [4564] [2690] [4214] [5230]

216

195

367

457

263

240

447

542

318

293

545

638

355

328

609

697

401

371

691

767

446

413

772

833

500

462

869

915

38.3 42.4 38.0 42.8 45.3 38.6 42.7 45.9 44.5 51.0 44.9 51.4 56.3 47.8 55.9 61.6 50.1 59.8 66.3

[17.4] [19.2] [17.2] [19.4] [20.5] [17.5] [19.4] [20.8] [20.2] [23.1] [20.4] [23.3] [25.5] [21.7] [25.4] [27.9] [22.7] [27.1] [30.1]

STL (Specified Tensile Load) 5,000 Lbs. [22.2 kN] Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings. For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Line Post Insulators Page LP-7 of LP-14


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Horizontal Line Post Insulators


H1-91 Series Insulators: [2.0 Rod Dia.]

Bendable Gain Base

Drop Tongue Bendable Gain Base


Line Voltage kV

MDCL
lbs [kN]

* Catalog No.
H191029VX01 H191029VX02 H191029VX03 H191034VX01 H191034VX03 H191034VX04 H191040VX01 H191040VX03 H191040VX03 H191044VX01 H191044VX02 H191044VX03 H191049VX01 H191049VX02 H191049VX03 H191054VX01 H191054VX02 H191054VX03 H191060VX01 H191060VX02 H191060VX03

Section Length in [mm]

Dry Arc in [mm]

Leakage in [mm] Dry

Electrical Flashover (kV)

60 Hz
Wet Pos

CIFO
Neg

Weight lbs [kg]

69 69 69 115 115 138 161


Notes:

1760 [7.8] 1433 [6.4] 1174 [5.2] 1051 [4.7] 923 [4.1] 828 [3.7] 736 [3.3]

29.0 [737] 34.0 [864] 40.0 [1016] 44.0 [1118] 49.0 [1245] 54.0 [1372] 60.0 [1524]

50.1 75.1 [564] 80.1 50.2 27.3 75.2 [693] 90.2 46.3 33.5 71.3 [851] 91.3 80.4 37.5 120.4 [953] 145.4 80.5 42.7 120.5 [1085] 150.5 95.6 47.8 145.6 [1214] 180.6 53.9 106.7 166.7 [1369] 206.7 22.2

[1273] [1908] [2035] [1275] [1910] [2291] [1176] [1811] [2319] [2042] [3058] [3693] [2045] [3061] [3823] [2428] [3698] [4587] [2710] [4234] [5250]

224

203

380

471

270

248

460

555

326

301

558

650

362

335

623

709

408

378

704

778

453

420

785

843

507

469

882

928

36.1 40.1 41.0 36.5 40.6 43.0 36.4 40.4 43.7 42.2 48.7 52.8 42.7 49.1 54.0 45.5 53.6 59.3 47.8 57.6 64.0

[16.4] [18.2] [18.6] [16.6] [18.4] [19.5] [16.5] [18.3] [19.8] [19.1] [22.1] [23.9] [19.4] [22.3] [24.5] [20.6] [24.3] [26.9] [21.7] [26.1] [29.0]

STL (Specified Tensile Load) 7,000 Lbs. [31.1 kN] Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings. For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Line Post Insulators Page LP-8 of LP-14


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Horizontal Line Post Insulators


NPKG Series Insulators: [2.5 Rod Dia.]

Fixed Gain Base


[To change from a gain base to a flat base, Change the G to a F as per catalog definition]

Trunnion Fixed Gain Base


Line Voltage
kV

MDCL
lbs [kN]

Catalog No.

Section Length
in [mm]

Dry Arc
in [mm]

Leakage
in [mm]

Electrical Flashover (kV) 60 Hz CIFO


Dry Wet Pos Neg

Weight
lbs [kg]

69 69 115
115 138

2500 [11.1] 2417 [10.8] 2140 [9.5] 1790 [8.0] 1573 [7.0] 1495 [6.7] 1337 [5.9] 1280 [5.7] 1201 [5.3] 1055 [4.7] 1201 [5.3] 1055 [4.7]

NPKG30XH016S0 NPKG30XH020S0 NPKG30XH023S0 NPKG30XH028S0 NPKG30XH032S0 NPKG30XH034S0 NPKG30XH038S0 NPKG30XH040S0 NPKG30XH043S0 NPKG30XH049S0

35.0 [889] 40.9 [1039] 45.4 [1153] 52.8 [1341] 58.7 [1491] 61.7 [1567] 67.6 [1717] 70.6 [1793] 75.0 [1905]

25.8 [655] 31.8 [808] 36.4 [925] 44.0 [1118] 50.0 [1270] 53.1 [1349] 59.1 [1501] 62.1 [1577] 66.7 [1694]

72.4 [1839] 90.7 [2304] 104.5 [2654] 127.5 [3239] 145.9 [3706] 155.1 [3940] 173.5 [4407] 182.6 [4638] 196.4 [4989]

256 311 352 419 473 500 553 579 618

234 287 325 388 438 462 510 533 567

436 532 604 724 821 868 964 1011 1082 1222

530 626 692 795 869 915 1006 1051 1118 1251

45.3 [20.5] 49.4 [22.4] 52.4 [23.8] 57.5 [26.1] 61.5 [27.9] 63.6 [28.8] 67.6 [30.7] 69.6 [31.6] 72.7 [33.0] 78.8 [35.7] 78.1 [35.4] 4.2 [1.9]

138
138 161

161 161 230 230 230 230


Notes:

83.9 75.8 224.0 696 635 [2131] [1925] [5690] The following insulators are designed with corona rings 75.0 [1905] 83.9 [2131] 62.2 [1580] 71.3 [1811] 196.4 [4989] 224.0 [5690] 580 658 533 602

NPKG30XH043S1 NPKG30XH049S1

1012 1153

1052 1186

STL (Specified Tensile Load) 5,000 Lbs. [22.2 kN] S0 - Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings. S1 - Electrical Data is with Corona Ring. For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Line Post Insulators Page LP-9 of LP-14


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Horizontal Line Post Insulators


NBKG Series Insulators: [2.5 Rod Dia.]

Bendable Gain Base


[To change from a gain base to a flat base, Change the G to a F as per catalog definition]

Trunnion Bendable Gain Base


Line Voltage
kV

MDCL
lbs [kN]

Catalog No.

Section Length
in [mm]

Dry Arc
in [mm]

Leakage
in [mm]

Electrical Flashover (kV) 60 Hz CIFO


Dry Wet Pos Neg

Weight
lbs [kg]

69 69 115
115 138

2500 [11.1] 2393 [10.6] 2123 [9.4] 1779 [7.9] 1567 [7.0] 1489 [6.6] 1333 [5.9] 1278 [5.7] 1199 [5.3] 1056 [4.7] 1199 [5.3] 1056 [4.7]

NBKG30XH016S0 NBKG30XH020S0 NBKG30XH023S0 NBKG30XH028S0 NBKG30XH032S0 NBKG30XH034S0 NBKG30XH038S0 NBKG30XH040S0 NBKG30XH043S0 NBKG30XH049S0

35.2 [894] 41.1 [1044] 45.6 [1158] 53.0 [1346] 58.9 [1496] 61.9 [1572] 67.8 [1722] 70.8 [1798] 75.2 [1910]

25.8 [655] 31.8 [808] 36.4 [925] 44.0 [1118] 50.0 [1270] 53.1 [1349] 59.1 [1501] 62.1 [1577] 66.7 [1694]

72.4 [1839] 90.7 [2304] 104.5 [2654] 127.5 [3239] 145.9 [3706] 155.1 [3940] 173.5 [4407] 182.6 [4638] 196.4 [4989]

256 311 352 419 473 500 553 579 618

234 287 325 388 438 462 510 533 567

436 532 604 724 821 868 964 1011 1082 1222

530 626 692 795 869 915 1006 1051 1118 1251

57.1 [25.9] 61.1 [27.7] 64.2 [29.1] 69.2 [31.4] 73.3 [33.2] 75.3 [34.2] 79.4 [36.0] 81.4 [36.9] 84.4 [38.3] 90.5 [41.1] 89.8 [40.7] 95.9 [43.5]

138
138 161

161 161 230 230 230 230


Notes:

84.1 75.8 224.0 696 635 [2136] [1925] [5690] The following insulators are designed with corona rings 75.2 [1910] 84.1 [2136] 62.2 [1580] 71.3 [1811] 196.4 [4989] 224.0 [5690] 580 658 533 602

NBKG30XH043S1 NBKG30XH049S1

1012 1153

1052 1186

STL (Specified Tensile Load) 5,000 Lbs. [22.2 kN] S0 - Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings. S1 - Electrical Data is with Corona Ring For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Line Post Insulators Page LP-10 of LP-14


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Horizontal Line Post Insulators


NBSG Series Insulators: [2.5 Rod Dia.]

Bendable Gain Base


[To change from a gain base to a flat base, Change the G to a F as per catalog definition]

Drop Tongue Bendable Gain Base


Line Voltage
kV

MDCL
lbs [kN]

Catalog No.

Section Length
in [mm]

Dry Arc
in [mm]

Leakage
in [mm]

Electrical Flashover (kV) 60 Hz CIFO


Dry Wet Pos Neg

Weight
lbs [kg]

69 69 115
115 138

2983 [13.3] 2443 [10.9] 2155 [9.6] 1801 [8.0] 1580 [7.0] 1503 [6.7] 1349 [6.0] 1287 [5.7] 1209 [5.4] 1062 [4.7] 1209 [5.4] 1062 [4.7]

NBSG30XH016S0 NBSG30XH020S0 NBSG30XH023S0 NBSG30XH028S0 NBSG30XH032S0 NBSG30XH034S0 NBSG30XH038S0 NBSG30XH040S0 NBSG30XH043S0 NBSG30XH049S0

34.8 [884] 40.7 [1034] 45.2 [1148] 52.6 [1336] 58.5 [1486] 61.5 [1562] 67.4 [1712] 70.4 [1788] 74.8 [1900]

25.8 [655] 31.8 [808] 36.4 [925] 44.0 [1118] 50.0 [1270] 53.1 [1349] 59.1 [1501] 62.1 [1577] 66.7 [1694]

72.4 [1839] 90.7 [2304] 104.5 [2654] 127.5 [3239] 145.9 [3706] 155.1 [3940] 173.5 [4407] 182.6 [4638] 196.4 [4989]

256 311 352 419 473 500 553 579 618

234 287 325 388 438 462 510 533 567

436 532 604 724 821 868 964 1011 1082 1222

530 626 692 795 869 915 1006 1051 1118 1251

54.4 [24.7] 59.3 [26.9] 61.1 [27.7] 67.4 [30.6] 71.4 [32.4] 73.5 [33.3] 77.5 [35.2] 79.5 [36.1] 82.6 [37.5] 88.7 [40.2] 88.0 [39.9] 94.1 [42.7]

138
138 161

161 161 230 230 230 230


Notes:

83.7 75.8 224.0 696 635 [2126] [1925] [5690] The following insulators are designed with corona rings 74.8 [1900] 83.7 [2126] 62.2 [1580] 71.3 [1811] 196.4 [4989] 224.0 [5690] 580 658 533 602

NBSG30XH043S1 NBSG30XH049S1

1012 1153

1052 1186

STL (Specified Tensile Load) 15,000 Lbs. [66.7 kN] S0 - Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings. S1 - Electrical Data is with Corona Ring For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Line Post Insulators Page LP-11 of LP-14


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Horizontal Line Post Insulators


H2-91 Series Insulators: [2.5 Rod Dia.]

Bendable Gain Base

Drop Tongue Bendable Gain Base


Line Voltage kV

MDCL
lbs [kN]

Catalog No.

Section Length in [mm]

Dry Arc in [mm]

Leakage in [mm] Dry

Electrical Flashover (kV)

60 Hz
Wet Pos

CIFO
Neg

Weight lbs [kg]

230 230 230

1019 [4.5] 979 [4.4] 907 [4.0] 1019 [4.5] 979 [4.4] 907 [4.0] 836 [3.7]

230 230 230 345


Notes:

86.0 78.4 153.3 [3894] H291086VX09 654 1262 H291086VX10 239.4 [6081] 719 [2184] [1991] H291086VX11 298.3 [7577] 90.0 82.5 152.9 [3884] H291090VX15 683 1324 H291090VX16 239.0 [6071] 753 [2286] [2096] H291090VX17 297.9 [7567] 97.0 89.7 155.5 [3950] H291097VX07 733 1431 H291097VX08 241.6 [6137] 813 [2464] [2278] H291097VX09 296.0 [7518] The following insulators are designed with corona rings 86.0 77.2 153.3 [3894] H291086VA05 645 1244 H291086VA06 239.4 [6081] 708 [2184] [1961] H291086VA07 298.3 [7577] 90.0 81.3 152.9 [3884] H291090VA07 674 1306 H291090VA09 239.0 [6071] 743 [2286] [2065] H291090VA10 297.9 [7567] 97.0 88.5 155.5 [3950] H291097VA03 724 1413 H291097VA04 241.6 [6137] 803 [2464] [2248] H291097VA05 296.0 [7518] 104.0 94.5 226.1 [5743] H291104VB02 765 1502 H291104VB03 285.0 [7239] 854 [2642] [2400] H291104VB04 357.5 [9081]

1289

1348

1450

72.9 84.8 93.0 73.7 85.7 93.9 75.7 87.7 95.2 77.9 89.8 98.0 78.7 90.7 98.9 80.7 92.7 100.2 91.6 99.8 109.9

[33.1] [38.5] [42.2] [33.4] [38.9] [42.6] [34.3] [39.8] [43.2] [35.3] [40.7] [44.5] [35.7] [41.1] [44.9] [36.6] [42.0] [45.4] [41.5] [45.3] [49.8]

1272

1331

1433

1518

STL (Specified Tensile Load) 15,000 Lbs. [66.7 kN] VX - Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings. VA Electrical Data is with an 8 Corona Ring. VB Electrical Data is with a 12 Corona Ring. For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Line Post Insulators Page LP-12 of LP-14


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Horizontal Line Post Insulators


H3-91 Series Insulators: [3.0 Rod Dia.]

Bendable Gain Base

Drop Tongue Bendable Gain Base


kV lbs [kN] in [mm] in [mm] in [mm] Dry Wet Pos Neg lbs [kg]

115 138 161 161 230 230 230 345

3263 [14.5] 2674 [11.9] 2239 [10.0] 2060 [9.2] 1852 [8.2] 1726 [7.7] 1671 [7.4] 1414 [6.3] 1414 [6.3]

345
Notes:

H391051VX06 75.9 [1928] 51.0 39.3 350 651 119.5 [3035] 378 H391051VX07 [1295] [998] 148.5 [3772] H391051VX08 H391060VX14 95.0 [2413] 60.0 48.7 427 800 H391060VX15 143.4 [3642] 462 [1524] [1237] 177.3 [4503] H391060VX16 H391069VX05 69.0 58.2 109.2 [2774] 502 949 H391069VX09 167.3 [4249] 544 [1753] [1478] H391069VX10 206.0 [5232] H391075VX08 75.0 64.4 110.7 [2812] 550 1047 168.8 [4288] 599 H391075VX06 [1905] [1636] H391075VX07 207.5 [5271] H391082VX04 82.0 71.8 151.9 [3858] 605 1160 H391082VX05 239.0 [6071] 662 [2083] [1824] 287.4 [7300] H391082VX01 H391087VX06 87.0 77.0 152.3 [3868] 643 1240 H391087VX07 239.4 [6081] 706 [2210] [1956] H391087VX08 297.5 [7557] H391090VX25 90.0 80.1 155.4 [3947] 666 1288 H391090VX26 237.7 [6038] 733 [2286] [2035] H391090VX27 295.8 [7513] 104.0 94.8 228.1 [5794] H391104VX07 767 1505 H391104VX08 358.8 [9114] 856 [2642] [2408] H391104VX09 387.8 [9850] The following insulators are designed with corona rings 104.0 92.2 228.1 [5794] H391104VB02 750 1468 H391104VB06 358.8 [9114] 834 [2642] [2342] H391104VB05 383.0 [9728]

734

854

992

1085

1192

1268

1313

1522

76.0 84.7 90.5 82.9 92.6 99.4 88.8 100.4 108.2 91.2 102.8 110.5 101.8 119.2 128.9 103.6 121.0 132.6 105.2 121.7 133.3 124.5 150.7 156.5

[34.5] [38.4] [41.1] [37.6] [42.0] [45.1] [40.3] [45.5] [49.1] [41.4] [46.6] [50.1] [46.2] [54.1] [58.5] [47.0] [54.9] [60.1] [47.7] [55.2] [60.5] [56.5] [68.4] [71.0]

1486

130.0 [59.0] 156.2 [70.9] 161.0 [73.0]

STL (Specified Tensile Load) 20,000 Lbs. [89.0 kN] VX - Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings. VB Electrical Data is with a 12 Corona Ring. For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Line Post Insulators Page LP-13 of LP-14


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Horizontal Line Post Insulators


NBSG40XV Series Insulators: [3.5 Rod Dia.]

Bendable Gain Base


[To change from a gain base to a flat base, Change the G to a F as per catalog definition]

Drop Tongue Bendable Gain Base

Line Voltage
kV

MDCL
lbs [kN]

Catalog No.

Section Length
in [mm]

Dry Arc
in [mm]

Leakage
in [mm]

Electrical Flashover (kV) 60 Hz CIFO


Dry Wet Pos Neg

Weight
lbs [kg]

115
115 138 138 161

5612 [25.0] 4672 [20.8] 3888 [17.3] 3505 [15.6]

NBSG40XV023S0 NBSG40XV028S0 NBSG40XV034S0 NBSG40XV038S0

48.5 [1232] 55.8 [1417] 64.6 [1641] 70.4 [1788]

36.4 [925] 44.0 [1118] 53.1 [1349] 59.2 [1504]

95.6 [2428] 116.5 [2959] 141.5 [3594] 158.2 [4018]

352 420 500 553

326 389 462 510

605 725 869 964

693 796 916 1006

110.1 [49.9] 118.0 [53.5] 127.5 [57.8] 133.8 [60.7]

161

Notes:

STL (Specified Tensile Load 15,000 lbs. [66.8 kN] MDCL = Max. Design Cantilever Load Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings. NBSG40 Series Insulators for use in North American Market Only For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Line Post Insulators Page LP-14 of LP-14


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Station Posts SP200


Silicone Rubber
The Si-O molecular bonds (inorganic backbone of Silicone) are very stable and have bond strengths higher than sunlight, making the silicone resistant to UV degradation. In addition to providing protection against ultraviolet radiation, electrical aging, and corona effect, silicone exhibits hydrophobic properties, which provide excellent recovery characteristics to control leakage currents in highly polluted or coastal environments. The MPS silicone rubber formulation has consistently outperformed other silicone formulations in its hydrophobicity, its hydrophobicity recovery rate, and enhanced electrical properties in contaminated environments.

Injection Molded
To protect the fiberglass rod, the housing is injection molded using high temperature and high pressure to bond to the surfaces of both the rod and end fittings into One Seamless Unit. By permanently protecting against rod degradation due to entry of moisture and contaminants, surface tracking and arcing of the resin rod is prevented.

Crimped End Fittings


All end fittings on injection molded distribution insulators are attached using a crimping process to achieve the required tensile strength. The cast iron and steel forged end fittings are galvanized for protection against corrosion, and are compatible with aluminum suspension clamps and conductors on line posts. This document intends to help users replace ANSI TR porcelain with Composite Station Posts The comparison with ANSI C29.9 Technical Reference No.s applies only for dimensional and electrical values. The Maximum Working Load (MWL) of the relevant TR porcelains are taken to be 40% of their cantilever rating. The Maximum Design Cantilever Load (MDCL) of the composite insulator is defined as the maximum load that can be permanently applied to the composite insulator without mechanical degradation. The Specified Mechanical Load (SML) is the cantilever load at which irreversible mechanical damage may be evident. In this document, the SML is the withstand cantilever strength of the composite insulator. The Height of the composite insulator matches exactly the height of the relevant porcelain insulator. The Deflection Values given in this document corresponds to the deflections measured at the relevant ANSI TR porcelain MWL. To evaluate deflections for other loads, the ratio of deflection / load is constant up to the MDCL.

Station Post Insulators Page: SP200-1 0f SP200-6


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Station Posts SP200


SP-200 Catalog Number Definition

N
Standards N ANSI F IEC

A
Bottom End Fitting

A 100 XH 13
Top End Fitting Rod Diameter Profile Type # of Sheds 100 2.5 Rod 200 3.5 Rod XH Profile Class 100 (2.5 Rod) XV -Profile Class 200 (3.5 Rod)

S
Rubber Housing S Silicone

0
Corona Ring 0- No Ring 1- w/ Ring
CR supplied automatically on insulators 900kv BIL <

A 5 BCD (4 tapped holes) P 5 BCD (4 through hole


pedestal) [Class 100 only]

See Drawing below

Standards
Complies with ANSI and IEEE standards + IEC tests. Seismically validated and tested as per IEEE 693.
(Certificates or numerical analysis available upon request)

Corona (Grading) Rings


Recommended for most applications with B.I.L. > 900kV. At lower voltages, corona rings may be considered for areas of high local contamination, and / or with altitudes > 3300ft. Where MPS considers them necessary, corona rings will be included in proposals.

Adaptor Plates
To comply with ANSI standards on 7 BCD fittings, MPS has adapted the use of 1 adaptor plates 5-7 shown here. The top adaptor plate, when needed, has integral slotted holes to facilitate alignment during erection of bus supports.
The use of adaptor plates increases the height of insulators by 1 or 2. For retrofitting, it is possible to adjust the total height to original TR value. Contact Factory.

Station Post Insulators Page: SP200-2 0f SP200-6


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Station Posts SP200

Corona Rings for Station Post Insulators


High voltages can result in unwanted noise (RIV) and corona. To minimize the effects of corona, corona rings are applied to one or both ends of the insulator (attached onto the end fittings). Typically, for system voltages 230kV and above a corona ring or combination of rings is necessary. However, some applications may require rings at lower system voltages. Refer to the Corona Ring section of the Application Guide for detailed information or contact the factory.

Recommended Corona Ring Application Table


138kV Standard Strength 100XH (2.5" Core) High Strength 200XV (3.5" Core)
None None

161kV
None None

230kV 12" 12"

315kV 12" 12"

345kV 12"

500kV 12"

For Insulators 230kV and above, MPS recommends use of Corona Rings. The Application Table above depicts typical corona ring usage on MPS station post insulators. For corona ring usage on special applications, environments, and elevations; please contact MPS.

Station Post Insulators Page: SP200-3 0f SP200-6


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Station Posts SP200


NAA100XH Series Station Posts
For Systems from

69kV to 315kV
B.I.L.: 350kV --- 1050kV
A End Fittings = 5 Bolt Circle w/ 4 tapped holes P End Fittings = 5 Bolt Circle w/ 4 through holes Class 100 = 2.5 Solid Rod HTV Silicone Rubber housing Exceeds the ANSI C29.9 Electrical requirements Tensile Strength = 17,500 lbs Torsional Strength = 32,000 in-lbs S1 = 12 Corona Ring (S0 = No Corona Ring)

Corona (grading) Ring: Recommended for most applications with BIL 900kV. At lower voltages, corona rings may be considered for areas of high local contamination, and/or with altitudes > 3300 ft. Where MPS considers them necessary, corona rings will be included.
Electrical Characteristics Mechanical Properties

Porcelain TR

Critical Im pulse

Line Voltage

W et W ithstand

BIL Rating

Com pression
lbs

Leakage

W ithstand M ax. RIV

Low Freq.

@ 1 M Hz Test Voltage

W eight

CIFO +

Height

to Ground

Catalog No.

kV

kV

Inch

Inch

lbs

Minimum Values kV kV kV

kV

lbs

lbs

Inch

69 115 138 161 230 315


Notes:

NAA100XH16S0 NAA100XH23S0 NAA100XH29S0 NAA100XH34S0 NAA100XH46S1 NAA100XH54S1

278 286 287 288 289 291 295 304 308 312 316

350 550 650 750 900

30.0

72.0

38 46 49 60 52 57

145 230 275 315 385 455

390 610 710 810 1010

350 550 650 750 900

200 200 200 200 500 500

44 73 88 103 146 146

4400 2800 2300 2000 1600 1400

2770 1750 1440 1260 990 870

25k 12k 8k 6k 3.4k 2.5k

0.7 1.9 2.9 2.6 4.0 3.1 4.8 5.0 7.6 6.4 9.6

45.0 106.1 54.0 133.7 62.0 156.7 80.0 211.8

1050 92.0 248.6

1210 1050

SCL = Specified Cantilever Load, MDCL = Max. Design Cantilever Load For P end fittings, replace the A with the P To order Station Posts, contact your local MPS Sales Representative. Station Posts for use in North American Market Only.

Station Post Insulators Page: SP200-4 0f SP200-6


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

@ TR M W L

Deflection

M DCL

SCL

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Station Posts SP200


NAA200XV Series Station Posts
For Systems from

69kV to 500kV
B.I.L.: 350kV --- 1470kV
A End Fittings = 5 Bolt Circle w/ 4 tapped holes Class 200 = 3.5 Solid Rod HTV Silicone Rubber housing HIGH STRENGTH Exceeds the ANSI C29.9 Electrical requirements Tensile Strength = 25,500 lbs Torsional Strength = 54,000 in-lbs S1 = 12 Corona Ring (S0 = No Corona Ring)

Adaptor Plate
To comply with ANSI standards on 7 Bolt Circle fittings, MPS has adopted the use of 1 adapter plates 5-7 shown here. The top adapter plate, when needed, has integral slotted holes to facilitate alignment during erection of bus supports. The use of adaptor plates increases the height of the insulators by 1 or 2. For retrofitting, it is possible to adjust the total height to the original TR value.
Electrical Characteristics Mechanical Properties

P orcelain TR

C ritical Im pulse

Line V oltage

W et W ithstan d

B IL R ating

C om pression
lbs

Leakage

W ithstand M ax. R IV

L ow Freq.

@ 1 MHz Test V o ltag e

W eight

C IFO +

H eight

to G round

Catalog No.

Minimum Values kV Inch Inch lbs kV kV kV V kV lbs lbs Inch

kV

69 115 138 161 230

NAA200XV15S0 NAA200XV24S0 NAA200XV28S0 NAA200XV33S0 NAA200XV45S1


278 286 287 288 289 291 295 304 308

350 550 650 750 900

30.0 45.0

62.0 99.0

53 69 77 86

145 230 275 315 385

390 610 710 810 1010

350 550 650 750 900

200 200 200 200 500

44 73 88 103 146

10,000 7,100 6,000 5,160 4,000

7,150 100k 0.2 4,470 3,630 3,120 2,370 40k 35k 25k 16k 0.5 0.8 0.7 1.1 0.9 1.4 4.6 7.0

54.0 117.5 62.0 138.3

80.0 188.4 110

Notes:

SCL = Specified Cantilever Load, MDCL = Max. Design Cantilever Load To order Station Posts, contact your local MPS Sales Representative. Station Posts for use in North American Market Only.

Station Post Insulators Page: SP200-5 0f SP200-6


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

@ TR M W L

D eflection

MDCL

SCL

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Station Posts SP200


NAA200XV Series Station Posts (contd)

A End Fittings = 5 Bolt Circle w/ 4 tapped holes Class 200 = 3.5 Solid Rod HTV Silicone Rubber housing HIGH STRENGTH Exceeds the ANSI C29.9 Electrical requirements Tensile Strength = 25,500 lbs Torsional Strength = 54,000 in-lbs S1 = 12 Corona Ring (S0 = No Corona Ring)

Corona (grading) Ring: Recommended for most applications with BIL 900kV. At lower voltages, corona rings may be considered for areas of high local contamination, and/or with altitudes > 3300 ft. Where MPS considers them necessary, corona rings will be included.

Electrical Characteristics

Mechanical Properties

Porcelain TR

C ritical Im pulse

Line Voltage

W et W ithstand

B IL R ating

C om pression
lbs

Leakage

W ithstand M ax. R IV

Low Freq.

@ 1 MHz Test Voltage

W eight

C IFO +

H eight

to G round

Catalog No.

Minimum Values kV Inch Inch lbs kV kV kV V kV lbs lbs Inch

kV

315 345 500


Notes:

NAA200XV53S1

NAA200XV62S1

NAA200XV73S1

312 316 362 324 367 369 330 371 373

1050 92.0 221.8 122

455

1210 1050

500

146

3,475

2,020

1300 106.0 259.3 137

525

1410 1300 1000

220

3,000

1,760

1470 122.0 305.2 154

590

1610 1470 1000

220

2,600

1,480

2.3 3.5 6.5 3.9 8.5k 5.7 8.0 5.4 6.5k 7.1 10.6 12k

SCL = Specified Cantilever Load, MDCL = Max. Design Cantilever Load 500kV Station Post listed above is designed with one 12 corona ring. This application requires two 12 corona rings. Contact MPS for details of NAA200XV73S2. To order Station Posts, contact your local MPS Sales Representative. Station Posts for use in North American Market Only.

Station Post Insulators Page: SP200-6 0f SP200-6


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

@ TR M W L

D eflectio n

MDCL

SC L

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Braced Post Insulators

Transmission line design must take into account economics, right-of-way, aesthetics, construction efficiency, and reliability. The composite braced post design is the clear choice to achieve each of these sometimes conflicting objectives. Composite Braced Posts allow the use of monopole structures vs. traditional lattice and H-frame construction significantly reducing the visual impact of the line as well as the right-of-way required to construct it. Composite Braced Posts vastly improve the vertical loading capability of conventional line posts allowing for greater span lengths and less total structures. Because they are composite and are made of silicone rubber, they also offer advantages of light weight, vandal resistance, and contamination performance unmatched by other insulator designs. Braced Post Assemblies are used effectively at system voltages from 69kv to 345kv. The composite braced post offers both urban aesthetics as well as a low environmental impact.

Above: Double Circuit Braced Post Structure Left: Braced Post vs. V-String Design Below: Lattice Structure

Braced Post Insulators Page BP-1 of BP-10


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Braced Post Insulators


Braced Post: Unique insulator design that combines the cantilever properties of a horizontal line post with the tension strength of a suspension insulator to make a high strength insulator assembly. The suspension insulator, or brace, is attached to the line post and to the tower via connection hardware. When loaded, the brace goes into tension, and is the primary support mechanism for the assembly. The line post provides stability for transverse (tension & compression) & longitudinal loads exerted onto the assembly. Connection Hardware: The hardware used to connect the brace to the post and tower can be supplied in a variety of combinations. Typically, the hardware used is greater than or equal to the SML rating of the brace insulator, and the type of connections is determined by the end fittings supplied on the suspension.
Options for connection hardware discussed in later sections.

Vertical Load: (MDCL) Downward load applied to the assembly, usually determined by the weight of the conductor. Tension Load: Transverse load pulling perpendicularly away from the tower, essentially putting the line post in tension. Compression Load: Transverse load pulling perpendicularly into the tower, compressing the line post towards the tower. Longitudinal Load: Side load applied to the assembly. Ideally, the load on each side of the assembly will be equal / balanced, resulting in no longitudinal load. Longitudinal loading is critical when loads are unbalanced and for broken conductor consideration. Combined Load Curves: Load curve that combines the effects of the various loads and plots working and ultimate strength of the assembly. Load curves are supplied upon request. Working Load Curve: The maximum load that can be applied to the insulator for long periods of time, without damaging or fatiguing the insulator. Ultimate Load Curve: The load at which the assembly approaches its ultimate strength, point of failure. Braced Post Load Application: The maximum load (or worst case load) of a specific application should fit right at or below the working load curve for that respective design. This max load is determined by the customer, and should take into account environmental influences (wind, ice, etc) along with the utilities safety factor practice. Max load applications that surpass the working curve require upgrades in strength for the braced post. Strength Upgrades: Depending on the specific loading requirements, there are many ways to upgrade the strength of a braced post, listed below are a few of the most common upgrades. Increase the SML of the brace insulator [~ increase Vertical Loading Capability] Increase the rod diameter of the line post [~ higher Vertical / Transverse Loading Capability] Change from fixed base to swivel base [~ improves Longitudinal Loading Capability] Dimensional design changes (Changes to upsweep angle, brace angle, height, etc.)

Braced Post Insulators Page BP-2 of BP-10


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Braced Post Insulators

Insulator Electrical Performance: The electrical values of an insulator are driven by the dry arc distance, and the insulators contamination performance is dictated by the leakage distance. Dry Arc Distance: the shortest distance metal to metal up and along the insulator tangent to the sheds. The electrical values for 60Hz & critical impulse flashovers are statistically derived by the dry arc distance of the insulator. Assembly Strike Distance: in a combination assembly, the individual dry arc distances of each insulator are usually not the shortest paths metal to metal. This shorter path or dry arc for the assembly is called the strike distance, which could be the distance from the post base to the brace end fitting or corona ring, or it could be the distance to the conductor hardware, especially on double bundled assemblies with horizontal yoke plates. The strike distance drives the electrical values of the braced post assembly.

The strike distance of the braced post assembly is typically shorter than the dry arc distances of either the post or brace insulators. Therefore, the electrical values of the individual insulators are greater than the electrical values of the assembly. The sketch above shows the various strike distances of the assembly, the shortest of which determines the electrical values.

Leakage Distance: the continuous path across the insulator from metal to metal, measured across the profile of each shed. The leakage distance is controlled by the number of sheds on the insulator. Assembly Leakage Distance: the leakage distance for a braced post assembly is the shortest leakage distance of the 2 insulators that make up the assembly. If the post has 230 of leakage, and the brace has 180 of leakage, the braced post leakage distance is 180.

Recommended Corona Ring Application for the Braced Post


Recommended Corona Ring Application
230kV Brace Post
Brace Ring Post Ring

345kV 12" Ring 6" Ring

8" Ring None

High voltages can result in unwanted noise (RIV) and corona. To minimize the effects of corona, corona rings are applied to one or both of the insulators of the assembly. Typically, for system voltages 230kV and above a corona ring or combination of rings is necessary. However, some applications may require rings at lower system voltages. The table above shows the recommended corona ring applications for 230kV & 345kV. The ultimate decision of corona ring application is determined by the customer and by the environmental factors where the assembly will be used.

Braced Post Insulators Page BP-3 of BP-10


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Braced Post Insulators


Braced Post Design Options

Insulator Options
Line Post: Typically, the line post of the braced post assembly will have a tongue line end fitting (F), and a bendable base tower connection (E). The bendable base is available as a gain or flat design type, or it can be replaced with a swivel or pivoting base, depending on the requirements of the application. Brace Insulator: The suspension insulator that makes up the brace can be comprised of many end fitting combinations, per customer preference. The Eye / Eye combination is a commonly used design, it offers a greater degree of articulation when combined with anchor shackles.

Bendable Gain

Bendable Flat

Swivel Base

Bendable Base Formed steel base that mates with an anchor end fitting on the insulator via 2 mounting bolts. These bases provide some vertical articulation of the post, which offers adjustment for the brace and connection hardware to the pole. Bendable bases come in gain and flat designs, with 0 & 12 upsweep angles, as required for by application. Gain Base base design used to mate the insulator to a round pole surface. This base is attached to the pole through the center bolt mount holes. Flat Base base design used to mate the insulator to a flat surface, using either the 4 bolt holes along the ears of the base, or the 2 center mount bolt holes Swivel Base or Pivoting Base This base provides articulation in the vertical and longitudinal directions. This design is typically used in areas where high longitudinal loading is required to compensate for unbalanced loads or broken conductor conditions. Pole Band Assemblies Another method of attaching a braced post assembly to a tower is by means of a pole band assembly. Pole bands are used on poles when mount holes are not available and cannot be drilled, or for maintenance / emergency response applications. Contact MPS for additional details.

Brace Connection Hardware Options


The brace of the braced post assembly can be made up of many different insulator and hardware combinations, depending on customer preference and design. The suspension insulator can make up the entire length of the brace, connected to the post and tower via anchor shackles. This is the simplest and more cost efficient design. The brace can consist of an electrically proportionate length suspension, combined with shackles for G1. & G2, and some form of steel hardware for item G3 (turnbuckle, straps, links, etc).
Options for G1. anchor shackle (SL = Eye) socket /clevis (SL=Y-Clevis) Options for G2. anchor shackle (SL = Eye) Options for G3. turnbuckle

EF Options for SSL


eye / eye eye / ball Y-clevis / ball

steel strap chain links

Braced Post Insulators Page BP-4 of BP-10


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Braced Post Insulators


Custom Braced Post Designs

The MPS Braced Post section of this catalog has many standard designs available for system voltages 69kV through 230kV. If the designs shown in the catalog do not exactly satisfy the requirements of an application, custom braced post designs are available. At the end of the braced post section is a braced post request worksheet, which is designed to communicate the specific details of a custom braced post design to MPS. The information provided on this sheet is used by MPS Design Engineering to develop the best fit design per customer request. In order to properly develop these designs, it is important to know the specific requirements of the application along with clarification about which details are most critical and which have some flexibility within the design. More Information = better designs and faster response time Braced Post Assembly Details: This section outlines the geometric / dimensional requirements of the assembly, including assembly height, section length, and angles. Ideally, the dimensions required would be expressed as a nominal value, with some +/- tolerances. When a specific dimension is absolutely required, it should be identified as critical. Not every dimension can be critical, as some dimensions of the assembly are driven by others, therefore only 2-3 dimensions should be marked as critical. Mechanical Loading Requirements: This section identifies the loading characteristics of the application. These values should be ultimate loads the assembly will be expected to withstand over long periods of time, and should fit within the working load curve of the assembly. Electrical Requirements: This section determines the minimal requirement of the assembly with respect to electrical performance. Minimum leakage distance (and / or description of contamination level for the application) Minimum strike distance / dry arc Minimum requirements for 2 of the 4 electrical values (ex. Dry FO & CIFO+) Corona ring requirement Assembly Details: The remaining sections identify the various options of the assembly Line post base requirement Extension hardware Suspension end fitting requirements Conductor information (armor rod) Hardware attachments Conductor attachment hardware

Hardware Assemblies & Packaging


MPS provides a single catalog number & drawing for each braced post assembly, whether it is a standard catalog item, or a custom design. The catalog number includes all the insulators, connection hardware, and conductor hardware as required, with all the various catalog numbers of the individual components bundled into one catalog number. Packaging: There are several options for packaging insulator assemblies. Typically, the individual components are bulk packed separately and mated in the field by the customer. Custom packs and tower packs are available upon request. These value added options reduce costs in the field, help minimize lost or missing parts, and reduce the time from receipt of goods to installation. Tower Packs: Unique packaging where each component of the assembly is packed into one crate, usually in quantities of 3, 6, or 9. MPS verifies fit and quantity of the components of the assembly. The crate can be marshaled out to the job site and dropped at the tower, where it can then be assembled and installed. Custom Packs: MPS packages components together as required by the customer. For additional information about braced post assemblies, contact your local MPS Sales Representatives

Braced Post Insulators Page BP-5 of BP-10


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Braced Post Insulators


Identification
A = 1.5 [38mm] (not included) (pole connection offset) B = Brace Length C = Brace Angle H = Assembly Height (Tolerance = +/- 3) SSL = Suspension Section Length PSL = Post Section Length
Line Voltage

B291 Series Braced Post w/ Bendable Gain Base

PSL
in [m m ]

SSL
in [m m ]

H
in [m m ]

C
Deg.

B
in [m m ]

kV

69 69 115 115 138

34.8 [884] 40.7 [1034] 45.2 [1148] 52.6 [1336] 58.5 [1486] 61.5 [1562] 67.4 [1712] 70.4 [1788] 74.8 [1900] 83.7 [2126] 89.6 [2276] 95.6 [2428]

38.0 [965] 44.0 [1118] 49.0 [1245] 58.0 [1473] 67.9 [1725] 70.0 [1778] 78.0 [1981] 81.0 [2057] 87.0 [2210] 99.0 [2515] 106.0 [2692] 113.0 [2870]

37.9 [963] 41.5 [1054] 44.8 [1138] 51.5 [1308] 59.8 [1519] 61.5 [1562] 68.2 [1732] 69.9 [1775] 75.0 [1904] 84.9 [2157] 90.0 [2287] 95.0 [2413]

54 51 50 50 51 50 51 54 50 51 51 50

43.5 [1105] 49.5 [1257] 54.5 [1384] 63.5 [1613] 72.5 [1842] 75.5 [1918] 83.5 [2121] 86.5 [2197] 92.5 [2350] 104.5 [2654] 111.5 [2832] 118.5 [3010]

List Of Materials
1) 2.5 Line Post Insulator (1 each) 2) 25klb Suspension Insulator (1 each) 3) ASH-55 Anchor Shackle (2 each)

138 161 161 161 230 230 230

Braced Post Insulators Page BP-6 of BP-10


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Braced Post Insulators

B291 Series Braced Post w/ Bendable Gain Base


Line Voltage kV

MDCL
lbs [kN]

Catalog No.

Section Length in [mm]

Dry Arc in [mm]

Leakage in [mm]

Electrical Flashover (kV)

60 Hz
Dry Wet Pos

CIFO
Neg

Weight lbs [kg]

69 69 115

10,402 B291035XL99A B291035XL99B [46.3] B291035XL99C 10,065 B291041XL99A B291041XL99B [44.8] B291041XL99C 9,910 B291045XL99A [44.1] B291045XL99B

34.8 [884] 40.7 [1034] 45.2 [1148]

23.3 [591] 28.8 [731] 33.2 [842]

47.9 59.5 72.4 50.0 73.2 90.7

[1217] [1511] [1839] [1270] [1859] [2304]

233

212

396

489

283

260

484

578

63.6 64.5 65.7 68.4 70.2 71.7

[28.9] [29.3] [29.8] [31.0] [31.9] [32.5]

78.2 [1986] 104.5 [2654]

323

298

553

645

72.2 [32.8] 74.3 [33.7]

9,829 B291052XL99A 52.6 40.6 75.6 [1920] 77.9 [35.4] 115 [43.7] B291052XL99B [1336] [1031] 95.0 [2413] 390 361 671 751 79.4 [36.0] 125.9 [3198] 81.8 [37.1] B291052XL99C 10,032 B291058XL99A 58.5 46.8 92.3 [2344] 82.8 [37.6] 138 [44.6] B291058XL99B [1486] [1189] 123.3 [3132] 444 411 769 830 85.2 [38.7] 145.9 [3706] 87.0 [39.5] B291058XL99C 9,918 B291061XL99A 61.5 49.7 91.5 [2324] 84.7 [38.4] 470 435 815 865 122.4 [3109] 87.1 [39.5] B291061XL99B 138 [44.1] [1562] [1262] 153.4 [3896] 89.5 [40.6] B291061XL99C 9,969 B291067XL99A 67.4 55.8 107.2 [2723] 89.6 [40.7] 161 [44.3] B291067XL99B [1712] [1417] 142.0 [3607] 523 483 911 956 92.3 [41.9] 173.0 [4394] 94.7 [43.0] B291067XL99C 9,870 B291070XL99A 70.4 58.7 106.0 [2692] 91.4 [41.5] 161 [43.9] B291070XL99B [1788] [1491] 141.2 [3586] 549 506 957 1000 94.1 [42.7] 182.6 [4638] 97.4 [44.2] B291070XL99C 9912 B291075XL99A 74.8 63.2 112.3 [2852] 94.7 [43.0] 161 [44.1] B291075XL99B [1900] [1605] 139.4 [3541] 588 541 1028 1067 96.8 [43.9] 193.6 [4917] 101.0 [45.8] B291075XL99C 9965 B291084AL99A 83.7 69.1 151.4 [3846] 107.3 [48.7] 230 [44.3] B291084AL99B [2126] [1755] 201.7 [5123] 639 585 1118 1153 111.2 [50.5] 224.0 [5690] 113.0 [51.3] B291084AL99C 9911 B291090AL99A 89.6 75.0 154.6 [3927] 111.3 [50.5] 230 [44.1] B291090AL99B [2276] [1905] 201.0 [5105] 690 629 1210 1240 114.9 [52.1] 239.7 [6088] 117.9 [53.5] B291090AL99C 9851 B291096AL99A 95.6 81.1 153.8 [3907] 115.0 [52.2] 230 [43.8] B291096AL99B [2428] [2060] 200.3 [5088] 741 673 1302 1328 118.6 [53.8] 258.3 [6561] 123.1 [55.9] B291096AL99C Data in this table corresponds with the Sketches on the previous page. Notes: MDCL = Max. Design Cantilever Load (Load Curves provided upon request) Electrical Data is derived from the assembly Strike Distance, without corona rings for 161kV and below. All 230kV Braced Post assemblies supplied with a corona ring (Electrical Values include the corona ring). For High Strength or Custom Designs, please complete the Braced Post Request Worksheet at the end of this section and return the competed worksheet to MPS through your local MPS Sales Representative. Customized Designs include any dimensional changes, strength changes, hardware changes, end fitting changes, gain to flat base changes, etc. NBSG Series Insulators for use in North American Market Only.

Braced Post Insulators Page BP-7 of BP-10


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Braced Post Insulators


Identification
A = 1.5 [38mm] (not included) (pole connection offset) B = Brace Length C = Brace Angle H = Assembly Height (Tolerance = +/- 3) SSL = Suspension Section Length PSL = Post Section Length
Line Voltage

B261 Series Braced Post w/ Swivel Base

PSL SSL
in [m m] in [mm ]

H
in [mm]

C
Deg.

B
in [mm]

kV

69 69 115 115 138

35.4 [899] 41.5 [1054] 46.1 [1171] 53.6 [1361] 59.7 [1516] 62.7 [1593] 68.8 [1748] 71.8 [1824]

48.0 [1219] 57.0 [1448] 64.0 [1626] 76.0 [1930] 85.0 [2159] 90.0 [2286] 100.0 [2540] 104.0 [2642]

43.4 [1102] 50.0 [1270] 55.3 [1405] 64.7 [1643] 71.3 [1811] 75.3 [1913] 83.3 [2115] 85.9 [2182]

51 50 50 50 50 50 50 50

53.5 [1359] 62.5 [1588] 69.5 [1765] 81.5 [2070] 90.5 [2299] 81.5 [2070] 105.5 [2680] 109.5 [2781]

List Of Materials
1) 2.5 Line Post Insulator (1 each)
[NCSA30XH Series Post]

138 161 161

2) 25klb Suspension Insulator (1 each)


[S199 Series Suspension]

3) ASH-55 Anchor Shackle (2 each)


Line Voltage kV

MDCL
lbs [kN]

Catalog No. B261036XL99A B261036XL99B B261036XL99C B261042XL99A B261042XL99B B261042XL99C B261046XL99A B261046XL99B B261054XL99A B261054XL99B B261054XL99C

Section Length in [mm]

Dry Arc in [mm]

Leakage in [mm]

Electrical Flashover (kV)

60 Hz
Dry Wet Pos

CIFO
Neg

Weight lbs [kg]

9,850

34.8 [884] 40.7 [1034] 45.2 [1148] 52.6 [1336]

21.5 [546] 27.4 [695] 31.9 [810] 39.3 [998]

69 69 115 115

[43.8] 9,761 [43.4] 9,730 [43.3] 9,736 [43.3]

54.0 57.9 72.4 63.0 74.6 90.1

[1372] [1471] [1839] [1600] [1895] [2289]

217

196

369

458

271

248

461

556

39.2 39.5 40.7 43.5 44.4 45.6

[17.8] [17.9] [18.5] [19.7] [20.2] [20.7]

77.7 [1974] 104.5 [2654] 82.0 [2083] 97.5 [2477] 127.5 [3239]

312

287

533

626

47.4 [21.5] 49.5 [22.5] 52.2 [23.7] 53.4 [24.2] 55.8 [25.3]

378

350

650

733

Braced Post Insulators Page BP-8 of BP-10


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Braced Post Insulators

B261 Series Braced Post w/ Swivel Base


Line Voltage kV

MDCL
lbs [kN]

Catalog No.

Section Length in [mm]

Dry Arc in [mm]

Leakage in [mm]

Electrical Flashover (kV)

60 Hz
Dry Wet Pos

CIFO
Neg

Weight lbs [kg]

58.5 45.3 94.9 B261060XL99A 122.0 B261060XL99B 138 [43.0] [1486] [1151] 145.2 B261060XL99C 9,700 B261063XL99A 61.5 48.3 96.0 119.2 B261063XL99B 138 [43.1] [1562] [1228] 154.0 B261063XL99C 9,709 B261100XL99A 67.4 54.4 109.9 161 [43.2] B261100XL99B [1712] [1382] 140.8 171.8 B261100XL99C 9,673 B261072XL99A 70.4 57.4 110.0 161 [43.0] B261072XL99B [1788] [1457] 141.0 182.6 B261072XL99C Data in this table corresponds with the Sketches on the previous page.
Notes:

9,664

[2410] [3099] [3688] [2438] [3028] [3912] [2791] [3576] [4364] [2794] [3581] [4638]

432

400

746

812

458

424

794

850

512

473

890

936

537

496

936

980

52.9 55.0 56.8 58.7 60.5 63.2 66.4 68.8 71.2 66.2 68.6 71.9

[24.0] [25.0] [25.8] [26.6] [27.5] [28.7] [30.1] [31.2] [32.3] [30.0] [31.1] [32.6]

MDCL = Max. Design Cantilever Load (Load Curves provided upon request) Electrical Data is derived from the assembly Strike Distance, without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings. For High Strength or Custom Designs, please complete the Braced Post Request Worksheet at the end of this section and return the competed worksheet to MPS through your local MPS Sales Representative. Customized Designs include any dimensional changes, strength changes, hardware changes, end fitting changes, gain to flat base changes, etc. NCSA Series Insulators for use in North American Market Only.

Braced Post Insulators Page BP-9 of BP-10


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN POWER SYSTEMS


Rev: A2, Date: 07/2004

Braced Post Insulators


Custom Braced Post Request Sheet

Braced Post Insulators Page BP-10 of BP-10


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com Product specifications are subject to continuous improvement and may be changed at any time without notification.