Contents Features Ordering data Preferred types Front panel Block diagram Technical data Device dimensions Page 1 2 2 2 3 4 5
Features
Suitable for actuating directly operated servo solenoid valves with non-linear curve (type 4WRPH...6, series 1X) Analog amplifiers in Eurocard format for installation in 19 rack Output stage with closed-loop control Enabling input Short-circuit-proof outputs Adjustment possibilities: valve zero Open-circuit detection for feedback signal cable Closed-loop position control with PID action Testing and service equipment Test box type VT-PE-TB1, see RE 30 063 Test adapter type VT-PA-3, see RE 30 070
2002 by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part, by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages. This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness. We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete or inaccurate information.
VT-VRRA1
1/6
RE 30 042/11.02
Ordering data VTHydraulic component For valves with electrical feedback Valve type Servo solenoid valve Actuation Analog
/
Option No code Servo solenoid valve with 0 10 V actuation RV = servo solenoid valve with + 3.5 6.5 9.5 V actuation V0 = Customer version Catalogue version Series Series 10 to 19 Servo solenoid valves with AC-Lvdt Serial numbers for types NG 6
=R
=R
=A 1X =
527 =
Type VT-VRRA1
VT-VRRA1-527-10/V0 VT-VRRA1-527-10/V0/RV
Front panel
RE 30 042/11.02
2/6
VT-VRRA1
VT-VRRA1
3/6
RE 30 042/11.02
Technical data (For device applications beyond the stated values, please consult us!)
P.C.B. format Plug connector Ambient temperature Weight m Power supply UB to b 16/b 18 and b 2/b 4 (0 V) (100 x 160 x approx. 35) mm (W x L x H) Europe format with front panel (7 modular spacings) DIN 41 612 F 32 0 C +70 C, storage temperature min. 20 C; max. +70 C 0.25 kg 24 V DC nominal, Battery voltage 2140 V, Rectified AC voltage Ueff = 2128 V (single-phase, full-wave rectification) 4,700 F/63 V DC, only required if UB ripple >10 % 2.7/25 (NG 6) 1.5 A The current rating can rise at min. UB and long cable length to control solenoid Max. 35 VA z 10 UE Difference amplifier z 12: 0 V z8 b 10 UE = 6.5 3 V UE = 0 10 V Oscill. b 26: 10.4 V/8 kHz Meas. tap z 28: 0 811 405 148 3.5 (6.5 V) 9.5 V 0 811 405 123 10 V (0 V) +10 V To z 16, U = 8.5 40 V, Ri = 100 k , LED (green) on front panel lights up Solenoid cable: up to 20 m 1.5 mm2 20 to 50 m 2.5 mm2 Feedback signal: max. 50 m at 100 pF/m Output stage to solenoid Signal to position sensor Potentiometer power supply Open-circuit protection for feedback signal cable Closed-loop position control with PID action Rapid energizing and de-energizing for fast response times Green: Enable Yellow: Feedback signal open circuit Red: UB < UBmin (21 V) z 26: No fault +24 V/0.1 A Fault: 0 V
Smoothing capacitor, separately to b 28/b 30 b 2/b 4 Valve solenoid A/VA max. Current rating
Short-circuit-proof outputs
Special features
LED displays
Fault signal Feedback signal open circuit UB too low Zero adjustment Fixed 0 811 405 148 Via trimming potentiometer 0 811 405 123 Note Connect power zero b 2 and control zero b 12 separately to central ground (neutral point).
RE 30 042/11.02
4/6
VT-VRRA1
VT-VRRA1
5/6
RE 30 042/11.02
Notes
Bosch Rexroth AG Industrial Hydraulics D-97813 Lohr am Main Zum Eisengieer 1 D-97816 Lohr am Main Telefon 0 93 52/18-0 Telefax 0 93 52/18-23 58 Telex 6 89 418-0 eMail documentation@boschrexroth.de Internet www.boschrexroth.de
The information contained herein is intended to serve purely as a product description. The information we have provided cannot be used as evidence of a particular aspect or of suitability for a particular purpose. Please note that our products are subject to the natural processes of ageing and wear.