You are on page 1of 2

JC International Limited

RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND ET


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 120113 Identification Number

Date of Examination

Examiner CHRISTOPHER DIESERU Description of Equipment TONG EXTENSION

Qualifications SNT LEVEL II MT, ET, LEEA II

10/07/2013
Qty

TC 1006 (200662-1)

Tong Extension

Date of next Examination: 09-01-2014

LOCATION : RIG FLOOR

SPECIFICATION: BS EN 1711 EXAMINATION AREA: CRITICAL AREAS


TEST METHOD: Phase Analysis testing (Vector Point Method)
EQUIPMENT MANUFACTURER GE Inspection Technologies (Phase 3S) EQUIPMENT MODEL NUMBER 401011 EQUIPMENT USED FREQUENCY SERIAL NUMBER

TEST PROCEDURE: JOP 700


PHASE ANGEL 48.5
0

8018UFR

100KHZ

CALIBRATION & REFERENCE BLOCK 0.5mm, 1.0mm & 2.0mm Artificial Notches (made by G.E.) S/N: 1075164/03

FREQUENCY 100KHZ

PHASE ANGEL 48.5


0

Name and address of equipment owner: TRANSOCEAN SUPPORT SERVICES

CALIBRATION DETAILS GAIN ( dB ) DISPLAY MODEL PROBE MODEL NUMBER Horizontal - 40.0 Weld Scan Probe Single Vertical 40.0 800PO4MB1P/1147351/04 Address of premises where Test / Examination was held: JACKRYAN

We hereby certify that on 10/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for Use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only Doc No: JCI-C-ET-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND ET


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 120114 Identification Number

Date of Examination

Examiner CHRISTOPHER DIESERU Description of Equipment TONG EXTENSION

Qualifications SNT LEVEL II MT, ET, LEEA II

10/07/2013
Qty

TC 1008

Tong Extension

Date of next Examination: 09-01-2014

LOCATION : RIG FLOOR

SPECIFICATION: BS EN 1711 EXAMINATION AREA: CRITICAL AREAS


TEST METHOD: Phase Analysis testing (Vector Point Method)
EQUIPMENT MODEL NUMBER 401011 EQUIPMENT USED FREQUENCY SERIAL NUMBER

TEST PROCEDURE: JOP 700


PHASE ANGEL 48.5
0

EQUIPMENT MANUFACTURER GE Inspection Technologies (Phase 3S)

8018UFR

100KHZ

CALIBRATION & REFERENCE BLOCK 0.5mm, 1.0mm & 2.0mm Artificial Notches (made by G.E.) S/N: 1075164/03 PROBE MODEL NUMBER

FREQUENCY 100KHZ

PHASE ANGEL 48.5


0

CALIBRATION DETAILS GAIN ( dB ) DISPLAY MODEL

Name and address of equipment owner: TRANSOCEAN SUPPORT SERVICES

Horizontal - 40.0 Weld Scan Probe Single Vertical 40.0 800PO4MB1P/1147351/04 Address of premises where Test / Examination was held: JACKRYAN

We hereby certify that on 10/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for Use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only Doc No: JCI-C-ET-01

You might also like