Locate the cables as far as possible from high-voltage lines and power lines. Otherwise, generated noise may cause product failure or malfunctions.
CAUTION
The N-L1 is a precision instrument. If the unit is dropped or shock is applied, it may be damaged. Use caution when unpacking, carrying, and mounting. Be sure to observe all warnings, cautions, and precautions specified in the manual.
N-L1
Instruction Manual
range of 0 to +50C or locations subject to condensation as the result of severe changes in temperature Locations where the ambient humidity is outside the range of 35 to 85%RH. Locations subject to corrosive or flammable gases Locations subject to dust, salts, iron dust, or oil smoke Locations subject to shock or vibration Locations subject to exposure of water, oil, or chemicals Locations where strong magnetic or electric fields are generated
DANGER
Failure to follow these instructions may lead to death or serious injury. Failure to follow these instructions may lead to injury. Failure to follow these instructions may lead to product damage (product malfunction, etc.). Provides additional information on proper operation. Indicates useful information or information that aids understanding of text descriptions.
WARNING
CAUTION
Note
TIPS
Caution - Do not connect directly to the branch circuit. This product must be power supplied by a suitable, approved isolating transformer or power supply having capacity not exceeding 200 VA max.
FCC regulations
The N-L1 complies with the following FCC EMI regulations.
FCC Part 15 Subpart B, Class B digital devices
avoid any damage in the event a problem occurs. If the N-L1 is used in any way other than described in the specifications or if modified, its functions and performance cannot be guaranteed. When the N-L1 is used in combination with other instruments, functions and performance may be degraded, depending on the operating conditions and the surrounding environment. Do not use the N-L1 for the purpose of protecting the human body. The information contained in this manual is subject to change without notice.
CE marking
The N-L1 complies with the following essential requirements of the EU Directive.
EMC Directive (2004/108/EC)
The following harmonized standards are applied to this product in order to confirm the compliance.
Applicable standards (EMI) Applicable standards (EMS)
EN55011, Class A
EN55022, Class A
Notice
When the product is used under the circumstances or environment below, adhere to the limitations of the ratings and functions, take countermeasures for safety precautions such as fail-safe installations and consult a KEYENCE sales representative.
For use under circumstances or environments which are not
EN61000-6-2
EN61000-6-1
* The length of the communication and power cables should be less than 30 m.
incinerators, medical equipment, entertainment equipment, safety devices etc. For use for applications where death or serious property damage is possible and extensive safety precautions are required
CAUTION
N-L1
Instruction Manual
0 to +50C or locations subject to condensation as the result of severe changes in temperature Locations where the ambient humidity is outside the range of 35 to 85%RH. Locations subject to corrosive or flammable gases Locations subject to dust, salts, iron dust, or oil smoke Locations subject to shock or vibration Locations subject to exposure of water, oil, or chemicals Locations where strong magnetic or electric fields are generated
DANGER
Failure to follow these instructions may lead to death or serious injury.
WARNING
CAUTION
Failure to follow these instructions may lead to product damage (product malfunction, etc.). Provides additional information on proper operation. Indicates useful information or information that aids understanding of text descriptions.
Note
When using the N-L1 Series as a UL approved product, be sure to observe the following installation and environment conditions.
Pollution degree 2 Overvoltage category I
TIPS
FCC regulations
avoid any damage in the event a problem occurs. If the N-L1 is used in any way other than described in the specifications or if modified, its functions and performance cannot be guaranteed. When the N-L1 is used in combination with other instruments, functions and performance may be degraded, depending on the operating conditions and the surrounding environment. Do not use the N-L1 for the purpose of protecting the human body. The information contained in this manual is subject to change without notice.
CE marking
The N-L1 Series conforms to the following essential requirements of the EU directive.
EMC directive 2004/108/EC
By checking the conformity to the following EN standards, the conformity to the essential requirements of the EMC directive is checked and the CE marking is indicated.
Conforming standards EMI EN55011, Class A
EN55022, Class A
Conforming standards EMS EN61000-6-2
Notice
When the product is used under the circumstances or environment below, adhere to the limitations of the ratings and functions, take countermeasures for safety precautions such as fail-safe installations and consult a KEYENCE sales representive.
For use under circumstances or environments which are not
EN61000-6-1
* The length of the communication and power cables should be less than 30 m.
incinerators, medical equipment, entertainment equipment, safety devices etc. For use for applications where death or serious property damage is possible and extensive safety precautions are required
CAUTION
The N-L1 is a precision instrument. If the unit is dropped or shock is applied, it may be damaged. Use caution when unpacking, carrying, and mounting. Be sure to observe all warnings, cautions, and precautions specified in the manual.
N?L1
Instruction Manual
to 85%RH.
Locations subject to corrosive or flammable gases Locations subject to dust, salts, iron dust, or oil smoke Locations subject to shock or vibration Locations subject to exposure of water, oil, or chemicals Locations where strong magnetic or electric fields are generated Failure to follow these instructions may lead to death or serious injury.
DANGER
WARNING
CAUTION
Failure to follow these instructions may lead to product damage (product malfunction, etc.). Provides additional information on proper operation. Indicates useful information or information that aids understanding of text descriptions.
CAUTION
Note
When using the N-L1 Series as a UL approved product, be sure to observe the following installation and environment conditions.
Pollution degree 2 Overvoltage category I
TIPS
FCC regulations
CE marking
The N-L1 Series conforms to the following essential requirements of the EU directive.
EMC directive 2004/108/EC
functions and performance may be degraded, depending on the operating conditions and the surrounding environment.
Do not use the N-L1 for the purpose of protecting the human body. The information contained in this manual is subject to change
By checking the conformity to the following EN standards, the conformity to the essential requirements of the EMC directive is checked and the CE marking is indicated.
Conforming standards EMI EN55011, Class A
without notice.
EN55022, Class A
Conforming standards EMS EN61000-6-2
Notice
When the product is used under the circumstances or environment below, adhere to the limitations of the ratings and functions, take countermeasures for safety precautions such as fail-safe installations and consult a KEYENCE sales representive.
For use under circumstances or environments which are not
EN61000-6-1
* The length of the communication and power cables should be less than 30 m.
CAUTION
CAUTION
E N-L1-IM
E N-L1-IM
E N-L1-IM
Pin number 1 2 3 4 5 6 7 8 9 10 11 12
Name OUT1 OUT2 TXD CTS OUT4 IN2 RXD RTS OUT3 IN1 +5V GND
Signal name For OUT1 input For OUT2 input Data transmission Transmission permitted For OUT4 input For IN2 output Data reception Transmission request For OUT3 input For IN1 input +5V power supply GND
Signal direction Input Input Input Output Input Output Output Input Input Output Output -
CAUTION
Communication status Monitors the status of communication with the head. LED LINK LED 100/10 LED Ethernet connection port I/O status LED I/O terminal Power terminal DIN rail mounting tab RESET/RUN switch Lights when the communication with an Ethernet unit is established. Lights when there is 100 Mbps communication. Goes off when there is 10 Mbps communication. Used to connect to an Ethernet unit. Monitors the ON/OFF status of I/O terminals. Used to connect I/O signal lines of control units. Terminal for 24V DC power supply input. A tab for mounting the DIN rail. A switch for switching the setting/run mode
Twist pair cable Power supply 24V+10% -20% Do not use a power supply other than 24 VDC. Otherwise, this may cause product failure. The N-L1 does not support PoE (Power over Ethernet). Be sure to supply 24 VDC power to the power terminal.
CAUTION
Head port
PLC
KV -B1 6X
HUB
IN1
OUT1 to 4
E N-L1-IM
Description Common for IN terminal Used as an input terminal for the code reader. Common for OUT terminal
50 mm or more on the top and bottom; no space is required on the right and left sides 50 mm 80 mm or more from the front
Output
Note
For connection, use stranded copper wire having a gage of AWG16 to 26 and temperature rating of 60C or higher. The tightening torque is 0.19 Nm (1.7 lbfin). 50 mm
80 mm
Installation precautions
When installing the N-L1, do not block the ventilation slots on the
INCOM
top and bottom of the unit. Otherwise, heat builds up inside the unit, causing product failure. If temperature on the bottom of the N-L1 could exceed the upper limit of the operating temperature (50C), take appropriate measures such as performing forced air cooling or ensuring proper ventilation by extending the space from the surroundings so that the temperature does not exceed the upper limit of the operating temperature (50C).
Internal circuit
Installing and removing the N-L1 to and from the DIN rail
Load Installing the N-L1 to the DIN rail
OUT COM
Circuit diagram
Mounting tab Crossover cable Personal computer * Use a cable of category 5 or higher. (Both STP and UTP can be used) * The extended length must not exceed 100 m. The N-L1 does not support PoE (Power over Ethernet). Be sure to supply 24V DC power to the power terminal.
Install the N-L1 to the DIN rail as shown in the following diagram.
Protrusion
CAUTION
DIN rail
When the installation direction changes, provide surrounding space so that heat does not build up.
For ventilation, keep a space of 50 mm or
Installing the N-L1 to the DIN rail 1. Hook Protrusion DIN rail Mounting tab
more on the top and bottom of the N-L1. As long as the N-L1 is the only source of heat generation, the N-L1 can be installed without space on the right and left sides. Because the head is connected, provide a space of 80 mm or more in the front of the N-L1.
2. Push
Bottom
E N-L1-IM
Dimensions diagram
57 44.2 41.8
After the N-L1 is removed, return the mounting tab to the state shown in A.
Specifications
General specifications
Model Power supply for the code reader Display Operating surrounding air temperature Storage ambient temperature Operating ambient humidity Operating atmosphere Vibration resistance Power voltage Consumption current N-L1 5 VDC 5% (650 mA) 11 LEDs (power supply status, data transmission/ reception status, I/O terminal status, LINK status, communication rate) 0 to 50C -20 to 60C 35 to 85%RH (no condensation) No dust or corrosive gases present 10 to 55 Hz, complex amplitude 1.5 mm, 2 hours in each of X, Y, and Z directions 24 VDC (+10%, -20%) 380 mA or less Approx. 155 g
Mass
I/O specifications
Number of pins Input format Input Input maximum rating Minimum ON voltage Terminal block Output Maximum OFF current Number of pins Output format Output rating load OFF time leak current ON time residual voltage 2 (IN1 and IN2) Bidirectional voltage input 26.4 VDC 15 VDC 1 mA 4 (OUT1 to 4) Photo MOS relay output 30 VDC, 100 mA 0.1 mA or less 1 V or less
Communication specifications
Connector Communication standards Head interface Communication rate Data bit length Parity check Stop bit length Flow control Connector Host interface Communication standards Total extended length 1 (12-pin round connector) RS-232C compliant 4800, 9600, 19200, 38400, 57600, 115200 bit/s 7/8 bits None/even/odd 1/2 bits Hardware flow control (mandatory) 1 (RJ-45) IEEE802.3 compliant 10BASE-T/100BASE-TX 100 m or less
Rating
Environment resistance
KEYENCE CORPORATION
1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan Phone: 81-6-6379-2211 Fax: 81-6-6379-2131
133.8
AFFILIATED COMPANIES
KEYENCE CORPORATION OF AMERICA Phone: 201-930-0100 Fax: 201-930-0099 KEYENCE DEUTSCHLAND GmbH Phone: 06102-36 89-0 Fax: 06102-36 89-100 KEYENCE (UK) LIMITED Phone: 01908-696900 Fax: 01908-696777 KEYENCE FRANCE S.A. Phone: 01 56 37 78 00 Fax: 01 56 37 78 01 KEYENCE ITALIA S.p.A. Phone: 02-668-8220 Fax: 02-668-25099 KEYENCE SINGAPORE PTE LTD Phone: 6392-1011 Fax: 6392-5055 KEYENCE (MALAYSIA) SDN BHD Phone: 03-2092-2211 Fax: 03-2092-2131 KEYENCE (THAILAND) CO., LTD Phone: 02-369-2777 Fax: 02-369-2775 KEYENCE TAIWAN CO., LTD Phone: 02-2718-8700 Fax: 02-2718-8711 KEYENCE (HONG KONG) CO., LTD Phone: 3104-1010 Fax: 3104-1080 KEYENCE INTERNATIONAL TRADING (SHANGHAI) CO., LTD Phone: 021-6875-7500 Fax: 021-6875-7550 KEYENCE KOREA CORPORATION Phone: 031-642-1270 Fax: 031-642-1271