This guide is delivered subject to the following conditions and restrictions: This guide contains proprietary information belonging to Rokonet Electronics Ltd. Such information is supplied solely for the purpose of assisting explicitly and properly authorized users of the Voice module. No part of its contents may be used for any other purpose, disclosed to any person or firm or reproduced by any means, electronic or mechanical, without the express prior written permission of Rokonet Electronics Ltd. The text and graphics are for the purpose of illustration and reference only. The specifications on which they are based are subject to change without notice. Information in this document is subject to change without notice. Corporate and individual names and data used in examples herein are fictitious unless otherwise noted. Copyright 2002 Rokonet Electronics Ltd. All rights reserved. This guide was written by DocuStar Documentation Services Ltd. (www.docustar.co.il).

Voice Module Installation Guide

Customer Information
RTTE COMPLIANCE STATEMENT Hereby, Rokonet Electronics Ltd, declares that this equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. RADIO FREQUENCY INTERFERENCE (Ref.: FCC Part 15, Para. 15.105) This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1. Reorient or relocate the receiving antenna. 2. Increase the separation between the equipment and the receiver.

Voice Module Installation Guide

3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 4. Consult the dealer or an experienced Radio/TV technician for help. CHANGES OR MODIFICATIONS (Ref.: FCC Part 15, Para. 15.21 and 15.27) Changes or modifications to this unit not expressly approved by Rokonet, Ltd., could void the users authority to operate the equipment.

Voice Module Installation Guide

Table of Contents
INTRODUCING THE VOICE MODULE ........6
Voice Module Main Features............................. 7 Technical Specifications .................................... 8 Mounting the Voice Module.............................. 8

VOICE MODULE COMPONENTS .................9


Channels.......................................................... 10 LED Indicators................................................. 11
Power LED ............................................................ 11 FM Comm LED...................................................... 12

Jumpers and Connectors ................................. 13


Jumpers ................................................................. 13 Connectors............................................................ 15

WIRING ......................................................16
Main Panel Wiring........................................... 16 MBU Wiring .................................................... 17 Terminal Block Wiring .................................... 18 NOTES............................................................. 21

Voice Module Installation Guide

Introducing the Voice Module


The Voice module provides audible information about the status of your ProSys system, and enables any remote, touch-tone (DTMF) telephone to act as a keypad for the system. Upon event occurrence, such as alarm activation, the Voice module informs you of a security situation, for example intrusion or fire, by calling you and playing a pre-recorded Event announcement. You can then acknowledge the event and remotely operate the system, as described in the Voice Module Programming and Operations Manual. Remote operation of the system includes a Listen and Talk option that enables you to listen in to your property and talk back, if necessary. It also includes the option to remotely activate or deactivate up to eight home appliances such as heating, lighting, sprinkler systems and garage doors. This guide discusses the tasks involved in installing the Voice module.

Voice Module Installation Guide

Voice Module Main Features


The following is a list of the main features offered by the Voice module: Remote DTMF operation Uncompromised security using access codes Smart voice answering detection Event acknowledgement User-friendly voice-prompt operation Large quantity of voice-synthesized messages User-recordable announcements Multi-point listen-in and announcement capability for up to 150m away Tamper input Remote/Local test modes Three separate audio channels Omni-directional microphone Message box unit integration

Voice Module Installation Guide

Technical Specifications
The Voice module has the following technical specifications: Wide operating voltage Current draw (standby) 9 to 14 Vdc 38mA 0-70C Max = 5Vpp Max = 2Vpp

Current draw (active speaking) 57mA Operating temperature Audio signal V in Audio signal V out

Mounting the Voice Module


The voice module should be mounted inside the metal box with the ProSys Main Panel in order to make a connection between the 2 units.

Voice Module Installation Guide

Voice Module Components


The following diagram shows the layout of components in the Voice module:

The following is a list of components in the Voice module: Channels, described on page 10. LED Indicators, described on page 11. Jumpers and Connectors, described on page 13.

Voice Module Installation Guide

Channels
The Voice module contains the following three channels, which are located on the voice module PC board: Audio Channel: Used for recording and announcing messages. When recording messages for UOs, zones, partitions and common message it is recommended to connect to a Message Box Unit (MBU) that has buttons to this channel. When the recording or message announcement is performed, all MBUs work in parallel and all microphones connected to this channel are activated.
NOTES:

Both internal and external microphones can be used for recording. In order to ensure the quality of the recording, connect the AUDIO channel to a single MBU only and speak the message into that MBU's microphone. (For more information about messages recording refer to the Voice Module Programming and Operations user manual) When you have finished recording approximately ten MBUs can be connected in parallel.

Listen-in Audio Channel: Used to listen and talk into the premises when using the Listen and Talk option, as well as for announcing messages. It is recommended to connect the MBUs without buttons to this channel. When the Listen and Talk option is used, all MBUs connected to this channel work in parallel (Approximately ten units)

10

Voice Module Installation Guide

Voice Channel: Used for communication between the Main Panel and the Voice Module. Connect the supplied cable from the Main Panel to the JP2 (See page 13).
NOTE:

The Voice terminals (IN COM OUT) are identical to the voice JP2 connector.

LED Indicators
The Voice module includes two LEDs that provide power and communication indications.

Power LED
The Power LED indicates the status of communication between the Voice module and the Main Panel. Condition Off On Slow Flash Description No voltage power from the main panel There is normal communication with the Bus. The LED starts to flash 15 seconds after communication with the Bus is interrupted, or during installation mode the voice module is not defined in the system.

Voice Module Installation Guide

11

FM Comm LED
The Follow Me Comm LED indicates the status of communication between the Voice module and the remote FM phone. Condition Off On Slow Flash Description There is no communication with the FM number. FM communication has been established. The Voice module is in the process of calling the FM number.

12

Voice Module Installation Guide

Jumpers and Connectors


This section describes the jumpers and connectors contained on the Voice module board.

Jumpers
The Voice module board contains the following three jumpers: Jumper 1, described below. Jumper 2, for future use. Jumper 3, for future use.

Jumper 1 Jumper 1 is used to select an external or internal microphone for recording messages. The following diagram shows the placement of the of the selector on jumper 1 when recording messages externally and internally:

EXT.

INT.

External: Place the selector on the (EXT.) pins as shown in the picture when recording messages from a microphone located on an MBU.

Voice Module Installation Guide

13

Internal: Place the selector on the (INT.) pins as shown in the picture when recording messages from the microphone located on the Voice module board.
NOTE:

The Jumper 1 selector must always be placed in either the EXT or the INT position.

14

Voice Module Installation Guide

Connectors
The Voice module board contains the following two connectors: BUS: Connects the Voice module to the 4-wire Bus. The AUX (RED), COM (BLK), BUS (YEL) and BUS (GRN) terminals are identical to the BUS connector and can be used for the same purpose. VOICE: Connects the Voice module to the VOICE connector on the ProSys Main Panel via the supplied cable. This connector transmits signals from the Voice module to the telephone line during remote communication, and is essential for normal operation of the Voice module.

NOTE:

An independently shielded cable can be used for a distance of up to 5 meters instead of the supplied cable.

Voice Module Installation Guide

15

Wiring
The Voice module is connected to the following two components: Main Panel, described on page 16. MBU, described on page 17. (Optional)

Main Panel Wiring


The Bus connector connects the Voice module to the Main Panel. Connect the wires in a form of terminal to terminal connection, from the appropriate terminals in the Voice module, to the appropriate connector on the panels BUS terminals, as follows: EXPANSION BUS TERMINALS AUX Color COM BUS BUS

RED

BLK (Black)

YEL (Yellow)

GRN (Green)

16

Voice Module Installation Guide

MBU Wiring
When connecting the MBU to the Voice module it is recommended to use one of the two wires for the IN and OUT connections (For both Audio and Listen In channels): Independently shielded wires: Used for Electro-magnetically Noisy Environment/Long Distance. The shield should be grounded. Independently twisted pared wires: Used for Electro-magnetically Unquiet Environment/Middle Distance. The second wire should be grounded to COM.

Other wires can be used for Electro-magnetically Silent Environment/Short Distance.


NOTES:

Do not run wires close to power (110/230 VAC), high-voltage wiring or any communication lines. Do not wrap or roll wires. All unused wires should be grounded by connecting them to the COM terminal. The maximum distance between each MBU and the Voice Module should not exceed 150 meter.

Voice Module Installation Guide

17

Terminal Block Wiring


The following table lists the connections that should be made between the Voice module terminal block and the MBU terminal block.
NOTES:

It is recommended to mount at least one Message Box Unit (MBU) that has buttons close to the keypad for easy messages recording.

Voice Module Terminal AUX COM

MBU Terminal AUX COM

Description 12 VDC that supplies power to the MBU.


NOTE:

All the AUX and COM terminals are connected in parallel.

LED

LED

Controls the MBUs LED indicator. The tamper terminal informs the software when the MBU is opened. These terminals

TMP

TMP

AUDIO1 IN

OUT AUDIO

18

Voice Module Installation Guide

Voice Module Terminal AUDIO1 OUT

MBU Terminal IN AUDIO

Description represent a channel that is used to record and sound messages for UOs, zones, partitions and so on, as described on page 9. These terminals should be connected to the REC and PLAY terminals in MBUs that have Record and Play buttons. Used to listen in to the premises when performing Listen and Talk, as described on page 10. All unused wires should be grounded by connecting them to the Listen-In COM terminal. See Listen-In IN, above.

REC PLAY

REC PLAY

Listen-In IN

OUT AUDIO

Listen-In COM

COM

Listen-In OUT

IN AUDIO

Voice Module Installation Guide

19

The Voice terminals (IN COM OUT) are identical to the voice connector JP2 and can be used when the supplied cable is too short to connect between the ProSys Main Panel and the Voice Module.

20

Voice Module Installation Guide

NOTES

Voice Module Installation Guide

21

Rokonet Limited Warranty


Rokonet Electronics, Ltd. and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 12 months from the date of production. Because Seller does not install or connect the product and because the product may be used in conjunction with products not manufactured by the Seller, Seller can not guarantee the performance of the security system which uses this product. Sellers obligation and liability under this warranty is expressly limited to repairing and replacing, at Sellers option, within a reasonable time after the date of delivery, any product not meeting the specifications. Seller makes no other warranty, expressed or implied, and makes no warranty of merchantability or of fitness for any particular purpose. In no case shall seller be liable for any consequential or incidental damages for breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever. Sellers obligation under this warranty shall not include any transportation charges or costs of installation or any liability for direct, indirect, or consequential damages or delay.

22

Voice Module Installation Guide

Seller does not represent that its product may not be compromised or circumvented; that the product will prevent any persona; injury or property loss by burglary, robbery, fire or otherwise; or that the product will in all cases provide adequate warning or protection. Buyer understands that a properly installed and maintained alarm may only reduce the risk of burglary, robbery or fire without warning, but is not insurance or a guaranty that such will not occur or that there will be no personal injury or property loss as a result. Consequently seller shall have no liability for any personal injury, property damage or loss based on a claim that the product fails to give warning. However, if seller is held liable, whether directly or indirectly, for any loss or damage arising from under this limited warranty or otherwise, regardless of cause or origin, sellers maximum liability shall not exceed the purchase price of the product, which shall be complete and exclusive remedy against seller. No employee or representative of Seller is authorized to change this warranty in any way or grant any other warranty. WARNING: This product should be tested at least once a week.

Voice Module Installation Guide

23

Contacting Rokonet
Rokonet Electronics Ltd. is committed to customer service and product support. You can contact us through our website (www.rokonet.com) or at the following telephone and fax numbers:

USA Tel: (305) 592-3820 Fax: (305) 592-3825 United Kingdom Tel: +44 (1527) 576-765 Fax: +44 (1527) 576-816 Italy Tel: +39 (02) 392-5354 Fax: +39 (02) 392-5131 Israel Tel: +972 (3) 9616555 Fax: +972 (3) 9616584 Brazil Tel: +55 (21) 2496-3544 Fax: +55 (21) 2496-3547
All rights reserved. No part of this document may be reproduced in any form without prior written permission from the publisher.

ROKONET ELECTRONICS LTD. 01/03

5IN128EVIM