QuotationWorksheetFilterVesselR100/R101
Copy,FillOut,&FaxBackto(215)679-6648

ASMEUStamp:___________(Yes/No)
*ASMECodeStampOurcompanionorganization,RushCertified,Inc.,isfullycertifiedtoprovidetheASMEBoiler&
PressureVesselCodeUStampasrequiredbymoststatesforunfiredpressurevesselsexceeding15psig.Each
vesselisregisteredwiththeNationalBoardofBoilerPressureVesselInspectors.Ourcodestampallowsdesign
serviceto3000psig.

*Allsystemsshould
becarefullypressure
tested,inspected,and
cleanedbeforebeing
placedinservice.
Otherspecialprocess
systemsaremany
timesrequired.

Mostjurisdiction(seetable)requirecertainvesselsto
complywiththeASMECode.Itistheresponsibilityofthe
endusertoverifytherequirementswithintheirjurisdiction,
andtoadviseifvesselsaretocontainlethalsubstances,i.e.
poisonousgasesorliquidsofsuchnaturethatverysmall
amountscouldbedangeroustolife(mixedorunmixedwith
air.)ASMECodeSectionVIIIDivision1coverspressure
vesselsforcontainmentofinternalorexternaloperating
pressureofgreaterthan15psimax.(nosizelimitation)or
(B)Vesselshaveaninsidediameterofgreaterthan6inches,
withoutlimitationonlengthorpressure.

GasType:______Air______NatGas______Other
GasSpec.Grav.:_________(ifotherthanair)
Flow:
NormalFlow:.._______SCF/_______(Min.,Hr.,Day)
MaximumFlow:.._______SCF/_______(Min.,Hr.,Day)
Connections:
InletSize_________Inch
InletType._________(Flange&Type,etc)
OutletSize_________Inch
*Onlyportionsofcode.
OutletType._________(Flange&Type)
AsuperiorFinish!Weuseahigh
Outletelevation......._________InchesAboveGrade
glossenamelthathasexceptional
MaterialsofConstruction:
TabulationoftheBoiler&PressureVesselLawsof
resistancetofungus,saltair,and
CarbonSteel__________(Yes/No)
theUS&CanadaJurisdictionVIII(1)
alkalis.Itistwiceascostlyaslesser
paintsthataredesignedinsteadto
304L.__________(Yes/No)
hideweldingandotherfabrication
316L.__________(Yes/No)
ALY
MOYWV.N
defects.Ourstandardgreyfinishis
AKN
MT....NWIY
other:.._______________________________
usedonallsheetmetalfilter
AZN
NB.YWY..Y
Pressure:
housings.Ifyouhavespecial
ARY
NV.YAlb..Y
requirementsforfinishing,letus
DesignPressure..._______________PSIG
CAY
NH....YB.C...Y
know.
OperatingPressure_______________PSIG
COY
NJ..YMan.Y
FlangeRating....._______________ANSI
CTN
NM...NN.B..Y
ResistanceTo:
Temperature:
DEY
NY.YN.F.&L...Y
2%HCL..NoEffect
DesignTemperature._..___________F
FLN
NC....YN.W.T.....Y
2%NaOH..NoEffect
GAY
NDYN.S.......Y
OperatingTemperature..___________F
5%Acid..NoEffect
HI.Y
OHYOnt...Y
LacticAcid.NoEffect
OtherPorts:
ID.Y
OK.YPEIs..Y
MineralOil.NoEffect
VentSize,inch_________Type:_________
SaltSpray,200hrs..NoEffect
IL..Y
OR.YQueY
DrainSize,inch.._________Type:_________
Flexibility180
IN.Y
PA.YSas..Y
PCapsSize,inch._________Type:_________
Mandrel,..NoCracking
IA.Y
PR.YY.Ter...Y
FungusResistanceperFederalSpec.
FilterElement:
KS.Y
RI..YAlbuquerque...N
TTP18,para.F3g.NoMildew
KY.Y
SC.NDesMoines..N
RetentionNeeded___________(Micron)
LA.N
SD.NMiami.N

MEY
TN.YNewOrleansY
ASightGlass..___________(Yes/No)
InternalFinish:DuetoConfiguration,Internaliscleanwater
MDY
TX.NTusconY
flushed&lightlyoiled.
BLiquidDump..___________(Yes/No)
MA.Y
UT.YUniversityCty..Y
CLevel/Float..___________(Yes/No)
MI.Y
VT.YDadeCo...Y
DCleanOut/Inspect___________(Yes/No)
MN.......Y
VA.....YJeffParish.Y

MS.Y
WA....YStLouisCo...Y

DistofClmb..Y
Details&SpecialRequirements______________________________________________

_____________________________________________________________________________________

___________________________________________________________________________
___________________________________________________________________________________

Precision Filtration Products P.O. Box 218 Pennsburg, PA 18073

Phone: 215-679-6645 Fax: 215-679-6648 sales@precisionfiltration.com www.precisionfiltration.com