You are on page 1of 1

GLOSTER CABLES LIMITED Survey No. 310/E, NH7, Kallakal (Vi), Toopran (Mn), Medak Dt. A.

P - 502 336 Tel: 91 8454 250511/12, Fax:- 91 8454 250510 TECHNICAL DATA SHEET CUSTOMER : M/s IKE ELECTRIC PVT LTD (SW) C0NSIGNEE : ISGEC MUMBAI

Tech/LT/CU/XLPE/HDPE/STRIP/13-14/0020 Date: 16-01-2014

DESCRIPTION: 1100Volts, Stranded copper conductor, XLPE Insulated, Wrapped thermoplastic tape Inner sheath Galvanized Steel strip armoured & Overall PVC ST2 Sheathed control Cable to IS: 7098 (Part 1) - 1988. 10CX2.5 2XFY TAP 24CX2.5 2XFY TAP 61CX2.5 2XFY TAP PARTICULARS DESCRIPTION UNITS SL No. Cable Size 24CX2.5 GLOSTER CABLES LIMITED, INDIA 1.0 Manufacture & Country 2XFY 2.0 Type of Cable IS: 7098 (Part-1) - 1988 3.0 Applicable Standard 1100 4.0 Rated Voltage Volts 50 5.0 Frequency Hz Voltage 10, Frequency 5 6.0 Permissible Voltage/Frequency variation % 24 7.0 Number of Cores Nos 8.0 Conductor 8.1 Material High Conductivity Plain Annealed Copper conductor, Class 2 to IS: 2.5 8.2 Nominal Cross Sectional area Sq. mm 7 8.3 Number of wires Nos Main/ 0.65 8.4 Nominal Diameter of wire (Before Stranding) mmNeutral 8.5 Shape of Conductor Stranded circular 9.0 Insulation XLPE to IS: 7098 (Part 1) - 1988 9.1 Material 0.70 9.2 Nominal Thickness of Insulation mm 9.3 Tolerance on Thickness mm The Smallest measured values of thickness of Insulation shall not fall 9.4 Specific Insulation Resistance -cm Minimum Volume Resistivity of Insulation at 27 C is 1x1014 & at 90 C Core Identification 9.5 Grey cores with Black number 10.0 Inner Sheath Thermoplastic tape 10.1 Material 0.30 10.2 Minimum Thickness of Inner Sheath mm 11.0 Armouring Single layer of Galvanized steel strip to IS: 3975 - 1999 11.1 Material 4.00X0.80 11.2 Nominal dimensions of Strip mmxmm 12.0 Outer Sheath PVC Type ST-2 to IS 5831-1984 12.1 Material 1.40 12.2 Minimum Thickness of Outer Sheath mm BLACK 12.3 Colour of Outer Sheath 26.10 12.4 Approximate Overall Diameter mm 13.0 Electrical Parameters 7.41 13.1 Max. DC resistance at 20C /Km 9.49 13.2 Max. AC resistance at 90C /Km 13.3 Approximate Reactance at 50HZ /Km #N/A #N/A #N/A 13.4 Approximate Capacitance F/Km #N/A #N/A #N/A 13.5 Maximum Impedance /Km #N/A #N/A #N/A 14.0 Continuous Current rating of the cable under Standard condition, when Laid 17 14.1 In Ground at 30C Amps 16 14.2 In Duct at 30C Amps 16 14.3 In Air at 40C Amps 0.358 15.0 Maximum Permissible Short Circuit Current kA One 15.1 Duration Sec 16.0 Maximum Conductor Temperature o 90 16.1 Continuous Operation C o 250 16.2 Short Circuit Operation C 1150 17.0 Approximate Net Weight of Cable Kgs/Km 5005% 18.0 Drum length with Tolerance mtr (5% of ordered quantity shall be in NSL with min length of 100 mtr) 12 X Overall diameter of the cable 19.0 Recommended Minimum Bending Radius mm 20.0 Recommended Maximum Pulling force, When 2 50 20.1 Pulled by Pulling Eye N/mm P = 9 X D 20.2 Pulled by Stocking N

PREPARED BY

APPROVED BY

You might also like