EM6400 Series Power Meters Chapter 1 EM6400 Series Power Meters Product Description

CTD7303 01/2011

Models and Parameters with EM6400 Series Power Meters


The power meter can measure, locally display and remotely transfer over Modbus RTU, the following parameters: Table 1-5: Models and parameters with EM6400 series power meters
Parameter RMS VLLV12, V23, V31 VLN V1, V2, V3 A A1 A2 A3 An Neutral current F %L Amps % V Unbal % A Unbal PF PF1 PF2 PF3 %A FS Analog color coded load bar RPM A Phase Angle A1 A2 A3 W W1 W2 W3 VA VA1 VA2 VA3 VAR VAR1 VAR2 VAR3 Demand VA/ W/ A Rising demand Time remaining Maximum Demand (MD) Hr MD occurred Wh VAh VARh -VARh Run hours ON hours INTR R.Wh R.VAh R.VARh -R.VARh Run hours Wh VAh VARh -VARh Run hours R.Wh R.VAh R.VARh -R.VARh Run hours RS 485 EM 6459 y y C y y y y y y y y y EM 6433 EM 6434 EM 6436 y y EM 6400 y y C y y y y y

y y

y y ~ ~ y y y ~ ~

y y y y y

DM

DM

INTG FWD

~ ~

y y

y y y

y y y y y y y

~ ~

y y y

y y y y y y y I/E

INTG REV

OLD FWD

~ ~

y y y y y

~ ~

y y y y y I/E

OLD REV

Built-in

Built-in

14

2011 Schneider Electric. All rights reserved.

CTD7303 01/2011

EM6400 Series Power Meters Chapter 1 EM6400 Series Power Meters Product Description

NOTE: Option specified while ordering; C Only through communication; ~ Selectable through setup. FWD: Forward indicating the import of power into the plant/grid REV: Reverse indicating the export of power from the plant/grid

y Standard;

The EM6400 series power meter displays: Voltage: Three voltage measurements line-to-line: 1-2, 2-3, 3-1, and average, Three voltage measurements line-to-neutral: 1-4, 2-4, 3-4, and average. Current: Three current measurements phase-wise (1, 2, 3), average current of all three phases, neutral current, and three current phase angles A 1, A 2, A 3) with respect to the corresponding voltage line-neutral (A vector. Phase wise load in %: Three currents in % of the FS (%A FS). Unbalanced load in %: Current and voltage unbalance. Frequency: Measures from whichever phase is active. RPM: Measures the speed of the generator. Power: VA, W, VAR, per phase and total. PF per phase and average. PerPhase W readings provide a quick CT Polarity Check. A negated W phase reading indicates CT reversal. Energy: VAh, Wh, +VARh (Ind), -VARh (Cap), Run hours, On Hrs, supply interruptions (outage). Energy (OLD): VAh, Wh, +VARh (Ind), -VARh (Cap), Run hours. % Amperes load bar graph: Load bar graph indicates consumption in terms of % amperes total. You can quickly estimate the load by viewing the display without operating any keys. The bar graph consists of 12 segments. Each segment indicates a current load of 10% of CT primary. Kilo, Mega, Giga indication for the above parameters. See The indicators on page 9 for more information.