DIGITAL INDICATING CONTROLLERS ON/OFF SERVO DIGITAL INDICATING CONTROLLERS

ACD-15A,ACR-15A
Indicating Controller

ACD-13A,ACR-13A

Visibility, Functionality

Industry leading large display

Easy status checking using 3-color switching

96

96

110

48

96

110

Easier viewing display


Simplified setting Set frequently used settings for streamlined usage.

A specially treated large LCD display makes it easier to view even in bright light and open-air. PV display (ACD series): 24.0 x 11.0mm (H x W)

Large LCD display

Industry Leading Large Display

Multi-Functions, Simple to Operate


PID zone function: PID ACD-13A, ACR-13A ACD-15A, ACR-15A
SV (desired value) PID zone setting

resetting due to SV change Unnecessary

Digital Indicating Controllers ON/OFF SERVO Digital Indicating Controllers

Up to 5 groups of PID parameters can be set. When SV is changed, PID parameters are automatically changed for optimal control. (It is not necessary to reset PID after SV is changed.)

Z o n e Z o n e
250 When changed 100

Setting PID Zone to 300

An easily viewable bar graph


22-segment bar graph allows simultaneous PV, SV, MV viewing. Ease of viewing for manual output operation. For the ACD-15A and ACR-15A, the motor valve opening can be checked with the bar graph. (when feedback potentiometer Yes is set)
MV indication
Scale is -5 to 105%, and bars light increasingly to the right in accordance with the MV.

ACD series

JCD-33A

Z o n e
Setting PID Zone to 200

Z o n e Z o n e
PID Zone changes from to

If SV is changed from 100 to 250, PID zone ( higher than 200, lower than 300 ) is automatically changed.

DV indication
In the case of zero (0) deviation, central 2 bars light. For positive deviation, bars light increasingly to the right. For negative deviation, bars light Increasingly to the left.

Simple operation in Simplified setting mode


Without setting engineering items, simplified setting mode can prevent operational mistakes, and simple operations run smoothly. Basic settings and key operations now are doable via 3-key usage.

(e.g.) MV 50%
-5%

105%

(e.g.) Deviation 0 (zero)


0

(e.g.) MV 100%
-5%

105%

(e.g.) Negative deviation


0

Enhanced visibility
PV display color selectable from red, green and orange. Colors can be set depending on the deviation between PV and SV, so status can be checked from a distance.
PV color continuous change mode
When PV is higher than the setting range

Power unnecessary if USB comm. cable used


Actual size
If CMB-001 USB communication cable (sold separately) is used, a power supply for the controller is not necessary. Wiring for the Initial setting is reduced. Data logging and monitoring can be carried out via the monitoring software (sold separately).

It is easier to see the SV, PV and setting characters, as an 11-segment LCD display is used.

When PV is within the setting range

All segments are backlit

SENS

ARW USB comm. cable (CMB-001) ACR-13A bottom PC Setting displays

PV display color is selectable from 7 modes below.


When PV is lower than the setting range

PV display: Green, Red, Orange Event output (any event from EVT1 to EVT5) Alarm OFF: Green, Alarm ON: Red Alarm OFF: Orange, Alarm ON: Red PV color changes continuously : Orange Green Red PV color changes continuously + Event output (any event from EVT1 to EVT5) ON (Red)

Feedback potentiometer Yes / No selectable

Selectable using the front keypad. If Yes is selected, feedback potentiometer position Fully Closed/Fully Open can be automatically adjusted. If No is selected, it is manually adjustable (only for ACD-15A, ACR-15A).

Model
ACD ACR ACD ACR 1 1 1 1 3 3 5 5 3 5 A R S A M 1 EI EVT3 EVT5 W W3 DR DS

Input type
- / M - / M - / M - / M
, , , , ACD-13A ACR-13A ACD-15A ACR-15A (W96 H96mm) (W48 H96mm) (W96 H96mm) (W48 H96mm)

K J R S B E T N PL - C(W/Re5 -26) Pt 100 JPt 100

DC current

4 to 20 mA DC 0 to 20 mA DC 0 to 10 mV DC 0 to 50 mV DC 0 to 100 mV DC 0 to 0 to 1 to 1 V DC 5 V DC 5 V DC

Control action
A1

control output (OUT1) input Supply voltage

Option (Multiple options selectable)

DA C C5 EA(0-20) EA(4-20) EV(0-1) EV(1-5) TA TV P24

PID ON/OFF servo output PID Selectable with the keypad operation (*1) Relay contact :1a1b (AC -15A: 1a x 2) Non-contact voltage(SSR drive): 12VDC 15% DC current: 4 to 20mA DC Multi-range (*2) 100 to 240V AC (Standard) 24V AC/DC (*3) Event input Event output (EVT1 to EVT3) (*4) Event output (EVT4, EVT5) Single-phase Heater burnout alarm (*4)(*5) 3-phase Relay contact: 1a Heating / Cooling Non-contact voltage(SSR control output drive): 12V DC 15% (OUT2) (*4) DC current: 4 to 20mA DC RS-232C Serial communication RS-485

-10 to 10 mV DC

Thermocouple

DC voltage

0 to 10 V DC

RTD

Terminal arrangement
ACD-13A
GND POWER SUPPLY 24V AC/DC

ACR-13A
1 2 3 4
NC

0 to 20mA DC 4 to 20mA DC External setting input 0 to 1V DC 1 to 5V DC 4 to 20mA DC Transmission output 0 to 1V DC Insulated power output 24V DC (*4)

2 3

POWER SUPPLY 100to240V AC

TRANSMIT OUTPUT

21

DI1 EVENT INPUT DI2 YA (TX) DI3 DI4

11 12 13 14 15
POWER SUPPLY 24V AC/DC

GND

1 2 3 4
NC

TRANSMIT OUTPUT

DI1 EVENT INPUT DI2

11 12 13 14 15 16 17

22 23
RS-485

2 3

POWER SUPPLY 100to240V AC

EXT CONT

EXT CONT

24 25

YB (RX) (RS-232C)

RS-485

YA (TX)

DI3 DI4

5
OUT1 NO CT1

SG COM

5
OUT1 NO

CT1

YB (RX) (RS-232C)

SG COM CT2

(*1): Alarm types (12 types and No alarm action) and status Energized/De-energized can be set by front keypad. (*2): Thermocouple, RTD, DC current or DC voltage is selectable by front keypad. (*3): For the supply voltage, 100 to 240V AC is standard. When ordering 24V AC/DC, enter 1 after the input code. (*4): Applicable to the ACD-13A, ACR-13A. (*5): The rated current (20A, 100A) for single phase and 3-phase is selectable by front keypad. The CT is sold separately. Not available for the DC current output type.

6 7
EVT3 NO

8
EVT2 NO

OUT2/ P24 EVT2 24V DC 30mA EVT1

7 8 9 10

3A 250V AC NO 3A 250V AC NO 3A 250V AC

26
CT2

16 17
5V mA NO 1V DC 3A 250V AC B B RTD A
EVT3

6 7
NO

27 28
EVT5

18
EVT2

8
NO

OUT2/ P24 EVT2 24V DC 30mA EVT1

7 8 9 10

3A 250V AC NO 3A 250V AC NO 3A 250V AC 5 4

EVT

NO NO

5V mA DC 1V

18 19
TC

9
EVT1 NO

29
EVT4 NO

19
TC

9
EVT1 NO

B B RTD

10

3A 250V AC

30

20

10

3A 250V AC

1A 250V AC

20

Specifications
Input
Thermocouple, RTD, DC current, DC voltage Thermocouple: Within 0.2% of each input span 1digit However, R, S input, -50 to 200 (-58 to 392 F): Within 6 (12 F) B input: 0 to 300 (0 to 572 F): Accuracy is not guaranteed. Accuracy K, J, E, T, N input, less than 0 (32 F): Within 0.4% of the input (Setting, span1digit Indication) RTD: Within 0.1% of each input span 1digit DC current: Within 0.2% of each input span 1digit DC voltage: Within 0.2% of each input span 1digit Input sampling period 0.125sec (0.25sec when EA, EV option is added) Relay contact: 1a1b (AC -15A: 1a x 2), Non-contact voltage (SSR drive), Control output DC current PID, PI, PD, P, ON/OFF action Control action 5 points (EVT1, EVT2: Standard, EVT3 to EVT5: Optional) Event output 100 to 240V AC 50/60Hz, 24V AC/DC 50/60Hz Supply voltage Power consumption Approx. 13VA Ambient temperature : 0 to 50 (32 to 122 F) Environment Ambient humidity : 35 to 85%RH (Non-condensing) Case material, color Material: Flame-resistant resin, Color: Black External dimensions ACD series: W96xH96xD110mm, ACR series: W48xH96xD110mm ACD series: 460g, ACR series: 330g Weight Heater burnout alarm, Heating/Cooling control, Serial communication, Options External setting input, Transmission output, Insulated power output Accessories sold Terminal cover, Heater burnout alarm (W, W3 option): CT for 20A (CTL-6S), CT for 100A (CTL-12-S36-10L1U), USB communication cable separately (CMB-001) For more details, please refer to the Spec sheet, which can be downloaded from the Shinko website. http://www.shinko-technos.co.jp/e
ensure safe and correct use, thoroughly read and understand the manual before using this instrument. instrument is intended to be used for industrial machinery, machine tools and measuring equipment. Verify correct usage after consulting purpose of use with our agency or main office. (Never use this instrument for medical purposes with which human lives are involved.) External protection devices such as protection equipment against excessive temperature rise, etc. must be installed, as malfunction of this product could result in serious damage to the system or injury to personnel. Also proper periodic maintenance is required. SAFETY This instrument must be used under the conditions and environment described in the manual. Shinko Technos Co., PRECAUTIONS Ltd. does not accept liability for any injury, loss of life or damage occurring due to the instrument being used under conditions not otherwise stated in this manual.
This To

ACD-15A
GND POWER SUPPLY 24V AC/DC POWER SUPPLY 100to240V AC

ACR-15A
1 2 3 4 5 21 22 23
RS-485 DI1 EVENT INPUT DI2 YA (TX) DI3 DI4

2 3

TRANSMIT OUTPUT

11 12 13 14 15
POWER SUPPLY 24V AC/DC

GND POWER SUPPLY 100to240V AC

1 2 3 4 5
OPEN NO

TRANSMIT OUTPUT

DI1 EVENT INPUT DI2

11 12 13 14 15 16 17

2 3

EXT CONT F.B.P. O NO W

EXT CONT

24 25 26 27

YB (RX) (RS-232C)

RS-485

YA (TX)

DI3 DI4

YB (RX) (RS-232C) FBP O W C EVT 5 4 NO 1A 250V AC DC

OPEN

SG COM

SG COM

6
CLOSE NO

16
CLOSE

6
NO

7 8 9
EVT1

3A 250V AC EVT5

17
5V mA NO 1V DC 3A 250V AC B B RTD A

7 8 9
EVT1

28 29

18 19
TC

3A 250V AC

NO NO

5V mA 1V

18 19
TC

NO

EVT4 NO

B B RTD

10

3A 250V AC

30

20

10

3A 250V AC

20

Caution with respect to Export Trade Control Ordinance


To avoid this instrument from being used as a component in, or as being utilized in the manufacture of weapons of mass destruction (i.e. military applications, military equipment, etc.), please investigate the end users and the final use of this instrument. In the case of resale, ensure that this instrument is not illegally exported.

This catalog is as of March 2008 and its contents are subject to change without notice. If you have any inquiries, please consult us or our agency.

SHINKO TECHNOS CO., LTD.


OVERSEAS DIVISION
Reg. Office : 2-5-1, Senbahigashi, Minoo, osaka, 562-0035, Japan Tel Fax URL E-mail : 81-72-727-6100 : 81-72-727-7006 : http://www.shinko-technos.co.jp : overseas@shinko-technos.co.jp
38-201-AC (E)

You might also like