Rebar Test Data Processing Software

Operation Manual

Beijing ZBL Science & Technology Co.Ltd.

Operation manual of rebar test data processing software

Contents
Conventions in This manual..2 1. 2. Brief introduction..3 Installation, Running and Uninstallation.5 2.1 Installation.5 2.2 Running.10 2.3 Uninstallation.10 3. Rebar measurement data processing software.13 3.1 3.2 Introduce on the software interface13 Menus22 3.2.1 File menu22 3.2.2 Edit menu33 3.2.3 View menu41 3.2.4 Evaluation menu42 3.2.5 Tools menu43 3.2.6 Language menu45 3.2.7 Help menu45 AppendixThe installation of USB driver..47

Hotline: 86-010-51290405

Fax: 86-010-51290406

Operation manual of rebar test data processing software

Conventions in This Manual


1. Word with gray background and black box is a button on the interface, e.g. OK. 2. 3. The keys on the instrument panel are represented by e.g. Word with white background and black box represent software SAVE. menu command in Windows, and is a separator between different menu levels. e.g. File Open means the command of selecting Open under the File menu. 4. Word with gray background but without box indicates the name of the control (choice box, input box, etc.) of the popup window on the screen, such as the input box of File Name in the open-file window. 5. The sign means special attention is needed here. 6. Besides the descriptions in the manual, some prompt messages may show automatically in the use of the software. Please operate accordingly. 7. The bitmap file in the operation manual is a graphics file with an extend name as BMP file. 8. Interface of this software comprises of multiple parts or views. A certain part will become the focus after it is clicked. 9. Window pictures for illustration in this manual are offered by the WindowXP system. Window style or name of this software will be slightly different when installed in other systems. 10. The software interfaces and photos in manual are only for reference. There will be changes with software upgrade and improvement of products. No further notice is provided.
Hotline: 86-010-51290405 2 Fax: 86-010-51290406

Operation manual of rebar test data processing software

Chapter 1 Brief introduction


The Process software for reinforcing steel bar measurement data (shorted as Rebar Process Software) is developed by Beijing ZBL Science & Technology Co., Ltd. The software operates as a Windows application program is mainly used to process the rebar test data obtained by a ZBL-R6 series rebar scanner. This process softwares interface is amity, convenient and the operation method, operation interface are compatible with the Windows style totally. The user who is familiar with Windows system is easy to master and use the software, which is specially designed for the user who work on engineering inspection. The software can running on the computer installed with Window95 or Window98, Windows Me, Windows XP, Windows2000, Windows NT operation system. This software has mainly the following features: 1) The management on all engineering information, object information and each measurement point data (such as the covers depth, diameter and position of rebar etc.) in the project. 2) The analysis and evaluation on the measurement data according to The acceptance criterion on construction quality for concrete construction (GB 50204-2002); 3) To figure out the graph of the object detection data, to make signal graph, position graph and gridding graph separately, from the signal graph scan, general scan, profile scan and grid scan, and to save which as the bitmap format, in order to edit them further by some other graph software.
Hotline: 86-010-51290405 3 Fax: 86-010-51290406

Operation manual of rebar test data processing software

4)

5) 6)

To merge many rebar test data file into one file; to add or delete object conveniently; to add or delete measurement point data conveniently. Preview for printing and printout for the measurement data. By Using a data transmission software, the measure data of rebar measurement can be transmitted to a computer, in order to analyze and backup further more.

This software consists of three different type files, as shown in tab. 1.1.
tab.1.1 File type list

Type
Date file Graphics file Text file

Ext.
ZRW BMP TXT

Description
Measuring data file Bitmap file ASCII code file

Hotline: 86-010-51290405

Fax: 86-010-51290406

Operation manual of rebar test data processing software

Chapter 2 Installation, Uninstallation

Running

and

The installation of the process software is similar with that of the ordinary Windows software. The installation and preparation before using the process software would be detailedly introduced in this chapter. All necessary files for installing this process software shall be kept in the CD or U-disk along with the instrument.

2.1 Installation
1. Please insert the CD or U-disk into the computer, find out the RebarSetup.exe file in the root directory and run it, the installing guide to unzip the needed files as shown in (fig. 2.1), after unzipping file finish, the InstallShield Wizard is automatically started up (fig 2.2) to guide the user how to install the software. After some minutes later, the welcome interface appears as displayed in (fig. 2.3) 2. On the welcome interface, if Cancel button is pressed to exit the installing program, after Next button is pressed to appear the customer information input dialog box as shown in fig. 2.4.

Hotline: 86-010-51290405

Fax: 86-010-51290406

Operation manual of rebar test data processing software

Fig2.1 Extracting files

Fig 2.2 Startup the installshield wizard

Fig. 2.3 Hotline: 86-010-51290405

Welcome interface 6 Fax: 86-010-51290406

Operation manual of rebar test data processing software

Fig. 2.4 Customer information dialog box

3. As shown in the fig. 2.4 customer information dialog box after you input user information and press the Back button, you can return to welcom interface as shown in fig. 2.3, or press Cancel button to exit installing program; Alternatively, you can press the Next button to appear the selecting destination folder dialog box as shown in fig. 2.5.

Fig. 2.5 Selecting destination folder dialog box Hotline: 86-010-51290405 7 Fax: 86-010-51290406

Operation manual of rebar test data processing software

4. As shown in the fig. 2.5 selecting destination folder dialog box, if Browse button is pressed, you can select the destination folder, after you complete setting the folder, you can press Back button to back to fig. 2.4 customer information dialog box or press Cancel button to exit installing program; Alternatively, you can press Next button to appear settings review interface as shown in as fig. 2.6.

Fig. 2.6

Settings review dialog box

5. In the fig 2.6 settings review dialog box, you can press the Back button to back to selecting destination folder dialog box as shown in fig. 2.5 or press the Cancel button to exit installing program; Alternatively, you can press the Next button to start to copy file, the screen can display the setup status dialog box as shown in fig. 2.7. The copy file time is dependent on the computer hardware configuration, from a few seconds to a few minutes. In this processing, you can press the Cancel button at any time to exit the installing program.

Hotline: 86-010-51290405

Fax: 86-010-51290406

Operation manual of rebar test data processing software

Fig.2.7 Setup status interface

Fig 2.8 Installation complete

6. After the copy file completion, the installation completion dialog box (fig. 2.8) is appeared, you can press Finish button to end installation, A shortcut mode icon to start up this process software can appear in both desktop and program group. When the installation is completed, a dialog box of restart computer at present will appear perhaps, please select this item, the computer
Hotline: 86-010-51290405 9 Fax: 86-010-51290406

Operation manual of rebar test data processing software

system can automatically restart again and complete installation. NOTE: Before installing the process software, please close all anti-virus software and firewall software etc., otherwise some troubles maybe appear during installation.

2.2 Running
After install completion, you can use a mouse to choose step by step StartAll ProgramsBeijing ZBLRebar Measurement Data Processing Software Rebar Measurement Data Processing Software, then run this process software. Besides, you can double click Rebar Measurement Data Processing Software icon to run this process software as well.

2.3 Uninstallation
After releasing a new version of the software, if you want to upgrade this software, first of all, the old version software has to be uninstalled. There are two methods to uninstall: 1) The same as other application program in Windows, in Control Panel , you can use a mouse to double click Add or Remove Program, in the dialog box, then to choose the software what you want to uninstall (Rebar Measurement Data Processing Software), then to click Remove button to startup installshield wizard, the rest procedure is same as method two. 2) You can choose StartAll ProgramsBeijing ZBLRebar Measurement Data Processing
10

SoftwareRemove

Rebar

Hotline: 86-010-51290405

Fax: 86-010-51290406

Operation manual of rebar test data processing software

Measurement Data Processing Software , startup installshield wizard, later on, as shown in the fig 2.9 installing option dialog box is appeared.

Fig. 2.9 Installing option dialog box

In the installing option dialog box, you can pitch on the third option---Remove, if you press Cancel button, then the uninstalling would not be carried out; if you press Next button, then start automatic uninstalling; the uninstall progress is displayed in fig. 2.10, after the uninstalling completion, as shown in fig. 2.11 dialog box is appeared, you can press Finish button to complete the process software uninstallation.

Hotline: 86-010-51290405

11

Fax: 86-010-51290406

Operation manual of rebar test data processing software

Fig. 2.10 Uninstalling progress dialog box

Fig 2.11 Uninstalling completion dialog box

NOTE: If you already install this process software, when reinstalling again, the installing option dialog box as shown in fig.2.9 will be appeared, here the user can choose the first item or the second item---Modify or Repair, then press Next button to complete upgrade of this process software.
Hotline: 86-010-51290405 12 Fax: 86-010-51290406

Operation manual of rebar test data processing software

Chapter 3 Rebar measurement data processing software


3.1 Introduce on the software interface
This software interface is made up of eight parts (see fig. 3.1): Title bar, Menu bar, Toolbar, Status bar, Object Info. Area , Object List Area, Data Area, Graph Area.

Fig 3.1 The main interface

1. In the Title bar from left to right there are the software icon, name of the current data file, software name and the three .The function of standard Windows application buttons three buttons are minimize, maximize/restore, close the program respectively.
Hotline: 86-010-51290405 13 Fax: 86-010-51290406

Operation manual of rebar test data processing software

2. The six menu items---File, Edit, View, Evaluation, Tools and Help -- make up the Menu bar, as shown in fig. 3.1. With each menu item is clicked to appear one rolling down menu, which consists of a series functions. The six items submenus contain all functions this software possesses. When some menu item are in a grey color state that expresses that its current function is inactive. 3. The Toolbar are made up of a series of buttons, as shown in fig. 3.2, each button can have one common-use function, although which are already contained in command menu, for these common-use commands, it is more convenient for the user to use toolbar buttons to complete the related operation. If you make mouse stay at one button for a moment, this buttons function tips can appear on the screen automatically. When this button is grey color state that means the current function button is inactive.
Fig 3.2 Toolbar

4. Status bar is used to display some short helping information or measuring points data. 5. Object Info. Area is used to display the currently selected objects information, which consists of Object name, type, Detection date and Design strength etc., referring to fig. 3.3. By clicking the Apply all button in the object information area, the user can make all objects information which consists of object type, design strength, production date, detection date and so on to be amended to same as the current object. Scanning space is used to express the distance between two scanning in the same direction, if you pitch on this item, you can input the scanning distance; if you dont do that, the system will automatically account on the distance between two reinforcing steel bars.

Hotline: 86-010-51290405

14

Fax: 86-010-51290406

Operation manual of rebar test data processing software

Fig. 3.3 Object information area

6. Object List Area is used to display all objects in the current file, as shown in fig. 3.4, this list is a tree-list, the objects are used as a father-node, the measuring lines or profile in each object are used as son-node, the user can click on the + mark in front of a father-node to extend the son-node display, when extended father-node, the user can click on the - mark in front of father-node to cache all the son-node. The user can double click the object node to extend or cache the object node. The user can use the mouses left button to click on some objects or measuring lines for choice. If the current focus locate in the object list area, the user can use , key to choose object or measuring line.

Fig 3.4 Object list area

Fig3.5 The popup menu

The user can click on the mouses right button in the object list area, to popup a menu as shown in fig. 3.5 in which the function is same as the corresponding item in the edit menu. If the current focus is located in the object area, then the first three items are
Hotline: 86-010-51290405 15 Fax: 86-010-51290406

Operation manual of rebar test data processing software

active, and the last two items are inactive; If the current focus is located in the measuring line or profile area, then the first three items are inactive, and the last two items are active. 7. Data Area is used to display the current object measuring points original measuring data, as shown in fig. 3.6. If there is a ---- display that means that there is no data, the data with a yellow shading are expressed as that are higher than the positive deviation tolerance, on the other hand, the data with a red shading are expressed as that are lower than the negative deviation tolerance. In the object list area, if one object is selected, then all the measuring lines or profiles are displayed, in there the user cannot amend the measure points measuring data. In the object list area, if one of the measuring line or the profile is chosen, then all measuring points data of the measuring line or the profile are displayed, the user can amend the measuring data (i.e. depth, diameter and position). The position is the distance between the reinforcing steel bar and the scan starting point, the distance is the distance between two reinforcing steel bars.

Fig 3.6 Data area

Fig 3.7 Popup menu Hotline: 86-010-51290405 16 Fax: 86-010-51290406

Operation manual of rebar test data processing software

When a measuring line or a profile is chosen in the object list area and a line or many lines are chosen in the data area, the user can click the mouses right button, to popup a menu as shown in fig. 3.7 in which the function is same as the corresponding item in the edit menu (the details refer to 3.2.2). 8. Graph Area is used to display current graph for the measuring line or the profile. In the graph area, the user can press the mouses left button and move it to left or right, the measuring distances, the depth values located in the mouse position are displayed in the status bar, if the mouse is moved to some one measuring point, the mouse become hand shape figure, then the measuring data in the measuring point is displayed in status bar.

Fig 3.8 Figure of general scan

If the current object is tested by general-scan, then after chosing the object, in the graph area is displayed as shown in fig. 3.8, the X-coordinate is the serial number of the measuring point, the
Hotline: 86-010-51290405 17 Fax: 86-010-51290406

Operation manual of rebar test data processing software

Y-coordinate is the depth of the concrete cover, there are three broken lines in the fig., the middle broken line is the design depth of cover, the top broken line is positive deviation tolerance line, and the underside broken line is negative deviation tolerance line. The graphic top part is the evaluation results of all measuring lines of the current object, which is the same direction as the current measuring line --- the maximum depth and the minimum depth, the average depth and eligibility level. On the top right corner for each measuring point there is a number which expresses the measuring value for concrete cover.

Fig 3.9 Figure of signal graph scan

If the current object is tested by fine scan (ZBL-R650), then after the object is chosen, the graph area is displayed as shown fig. 3.9, the X-coordinate is the scanning distance, the signal value is displayed in graphic area. The graphic top part is the evaluation results of all measuring lines of the current object, which is the
Hotline: 86-010-51290405 18 Fax: 86-010-51290406

Operation manual of rebar test data processing software

same direction as the current measuring line--- the maximum depth and the minimum depth, the average depth and eligibility level. If the bar diameter are measured, the blue circle in the figure is the sketch map for the reinforcing steel bar and the sideward value is the diameter on the measuring point; if the bar depth is measured, the inverse triangle in the fig. is used to express as the depth sketch map, the sideward value is the depth of concrete cover. The user can click the mouses left button and move it on left or right to appear a vertical judge line to any position in the signal figure, the user can click on the add depth in the toolbar to add a depth value, or click on the delete depth in the toolbar to delete depth value; The user can click on the mouses right button and move it up or down to appear landscape orientation judge line, by loosing the mouses right button, the updated depth measuring values based on the landscape orientation judge line refreshing are displayed in the data area, the depth sketch map in the graphic area is the results from the signal values in the landscape orientation judge line. If user double click on the graphic area, a dialog can be shown as in the fig. 3.10, to adjust the displaying scales of X-axis or Y-axis.

Fig 3.10 Display scale dialog box

If the current object is tested by profile scan (ZBL-R630, ZBl-R650), then the user should choose a measuring line, the graph is displayed in the graphic area as shown in fig. 3.11, the X-coordinate is the distance, the Y-coordinate is the depth, in the
Hotline: 86-010-51290405 19 Fax: 86-010-51290406

Operation manual of rebar test data processing software

figure there are three broken lines, the middle broken line is the designed depth of the cover, the top broken line is the positive deviation tolerance line, and the underside broken line is the negative deviation tolerance line. The graphic top part is the evaluation results of all measuring lines (or profile) of the current object, which is the same direction as the current measuring line (or profile) --- the maximum depth and the minimum depth, the average depth and eligibility level. On the right top corner for each measuring point there is the number which is the depth of the cover. The black measuring point is expressed as just only the diameter without the depth being measured in this position. If user double click on the graphic area, a dialog box can be shown as in the fig. 3.10, to adjust the displaying scales of X-axis or Y-axis.

Fig 3.11 Figure of profile scan

Hotline: 86-010-51290405

20

Fax: 86-010-51290406

Operation manual of rebar test data processing software

Fig 3.12 Figure of grid scan

If the current object is tested by grid scan (ZBL-R630, ZBL-R650), then after the user choose the object, the rebar distribution graph is displayed in the graphic area as shown in fig. 3.12, the X-coordinate is the distance between the vertical rebars, the Y-coordinate is the horizontal rebars, in the figure there are some small round points, which is the depth of the cover, the yellow color round points are higher than the positive deviation tolerance, and the red color round points are lower than the negative deviation tolerance. On the right bottom corner for each measuring point there is the number which is the depth of the cover. If user double click on the graphic area, a dialog box can be shown as in the fig. 3.10, to adjust the displaying scale of grid.
Hotline: 86-010-51290405 21 Fax: 86-010-51290406

Operation manual of rebar test data processing software

The graphic top part is the evaluation results of the current object --- the maximum depth and the minimum depth, the average depth and eligibility level. For each item result, the display format is expressed as XX/YY, the numerator expresses all evaluating results from the X direction scanning the reinforcing steel bar, the denominator expresses all evaluating results from the Y direction scanning the reinforcing steel bar.

3.2 Menus
3.2.1 File menu
1 Open By using this software, the user can open the data file which is transmitted from the instrument to computer (the ext. is ZRW). After opening data, as shown in fig.3.1, the corresponding data or information can be displayed in the related area in the interface.

Fig 3.13 Open file dialog box Hotline: 86-010-51290405 22 Fax: 86-010-51290406

Operation manual of rebar test data processing software

After the Open menu is chosen, the open file dialog box is appeared as shown 3.13, the user can choose the wanted opening file folder from the Look in, meanwhile choose the wanted opening file type from the Files of type, the user can input the wanted opening file name in File name or from file list frame to choose the wanted opening file, then the user can press Open button to open the file. Before the user open a new file, if the current file has been modified, an yes/no save hint is appeared, if the user choose Yes to save the file; whereas if choose No, to give up saving it; if the user choose Cancel, so that no any operation is carried out. 2 Save The user can save the current data file. 3 Save as

Fig 3.14 Save as dialog box

The user can make the current opening file to save as a new file. After the user choose Save as menu, the save as dialog box is appeared as shown in fig. 3.14, the user can choose the wanted saving file folder in the Save in frame, and input file name in the File name frame and
Hotline: 86-010-51290405 23 Fax: 86-010-51290406

Operation manual of rebar test data processing software

press Save button to save the file, or press the Cancel button to give up. Before the user save the file, if there is a existed file with a same name, then a dialog box is appeared to ask if you want to overwrite this file, if the user choose Yes, so that the existed file is overwritten; if user choose No, so that the saving is given up and the interface return as shown in the fig. 3.14, the user can input a new file name again. 4 Save the selected objects The user can save the selected objects of current file as a new file. The user can choose the Save the selected menu, a dialog box is appeared as shown in the fig.3.15, from the Objects list frame the user can select one or more object, then press OK button, the save as dialog box is appeared as shown in the fig.3.14, the user can input file name and press the Save button to complete it.

Fig3.15

Save the selected objects dialog box

5 Save bitmap After the user choose Save bitmap, a dialog box is appeared as shown
Hotline: 86-010-51290405 24 Fax: 86-010-51290406

Operation manual of rebar test data processing software

in the fig 3.16, the user can choose All objects or Current object, in the range, depending on the different instrument type, the user can choose the highlight items from the General scan, Profile scan, Grid scan, Fine scan, (by making a tick on the corresponding item to express pitch on. Due to the different instrument with the different scanning style, different optional items ). After the choice completing, the user can press Cancel button to exit it and give up creating bitmap or press OK button, the folder choose dialog box is appeared (as shown in the fig. 3.17), the user can choose the objective folder for saving the bitmap file, after the user choose completed and press the OK button, a sub folder named as the project name (if the project name is empty, which is named as Rebar) will be created under the chosen objective folder, all of the bitmap will be saved in this sub folder and the file name is default.

Fig.3.16 Bitmap setup dialog box

Hotline: 86-010-51290405

25

Fax: 86-010-51290406

Operation manual of rebar test data processing software

Fig 3.17 Browse for Foler dialog box

NOTE: For grid scan objects, each object graph is saved as a file and the file name is defaulted as object name.bmp. For the general and profile scanning object, each measuring line or profile graph is saved as a file and the file name is defaulted as object namethe measuring line number. bmp. 6 Export text The user can save the current opening file as a text format file (ASCII code) and can open it with Notepad or other software program. After the user choose Export Txt , as shown in the fig . 3.14 save as dialog box , the user can choose the wanted saving file folder in the Save in frame and input the file name in the File name frame, then press Save button to save the file, or press Cancel button to give up. The default file name is same as current opening file, for example, if the current opening file name is rrr.zrw, then the default file name is rrr .txt.
Hotline: 86-010-51290405 26 Fax: 86-010-51290406

Operation manual of rebar test data processing software

7 Import text The user can transfer the text files from R610 rebar scanner to ZRW file. After the user choose Import Txt , a open file dialog box will be shown, the user can choose the wanted file or input the file name in the File name frame, then press Open button to transfer the file, or press Cancel button to give up. 8 Import data The user can convert data files with ext. name 801 into the format which can be open with the software. After selecting into Import 801 Data menu, it will pop-up "open file" dialog box, the user can choose the converting file folder from the Look in, input the converting file name in File name or from file list frame to choose the converting file. After clicking the Open button, the file can be converted into the ZRW format and be saved. The name and saved position of the ZRW format file are same with the data file. The ZRW format file can be automatically open after the converting work. 9 Merge file This function is mostly used to combine more than two ZRW files as one file, to make the user manage the files more conveniently.

Fig 3.18 Merging files dialog box Hotline: 86-010-51290405 27 Fax: 86-010-51290406

Operation manual of rebar test data processing software

After the user choose Merge menu, as shown in the fig. 3.18s dialog box, firstly to press Browse button, choose one or more ZRW file, then press Open button, the selected files to be merged can be displayed in the Files to be merged list, then press Merge button, the save as dialog box will popup, the user input the file name to be saved and then press Save button, after that the selected files to be merged and saved then exit. In the merging file dialog box, if the user press Cancel button, so that to give up file combination and exit. If user double click on the mouse left button in Files to be merged list, then the list frame become empty, in order to choose other data file else. NOTE: This software is compatible with all ZBL-R6 series instrument, when the user combine the files please dont combine the data files from the different type instrument, otherwise which maybe bring out some displaying deviation. 10 Print setup Before printing, users can do some print setup. After selecting the Print setup menu, users will see the pop-up Print Setup dialog box in fig.3.19. There are three pages in the dialog box, namely, General, Header & Footer, and Table Header Information, which are showed from fig.3.19(a) to fig.3.19 (c). By clicking the left mouse on the label, users can change the page to the corresponding one and go on different print setup on each page. In General page, users can set up page margins, print range and content and paper type, etc. In Header & Footer page, users can choose whether print Page Number or not(when decide to print the page number, users can set up
Hotline: 86-010-51290405 28 Fax: 86-010-51290406

Operation manual of rebar test data processing software

the position, format and the starting page number) whether print Page Header or not (when decide to print the header, users can set up the position, height and content of header ), whether print Page Footer or not (when decide to print footer, users can set up the position, height and content of footer) and the Header & Footers font, etc. In the Table Header Information page, the list box of Pintable Header lists all the printable header information and the list box of Selected Header lists all the selected header information to be printed. By selecting one or more items in the list box of Pintable Header and pressing the Add button, users can transfer all the selected ones to the list box of Selected Header; by selecting one or more items in the list box of Selected Header and pressing the Remove button, users can remove the selected ones from the list box of Selected Header. Also after selecting a certain item in the list box of Selected Header, users can adjust the sequence of header information in the printout by pressing the Up button and Down button. By pressing the Add All button, users can transfer all the printable header information to the list box of Selected Header. By pressing the Clear button, users can remove all the header information from the list box of Selected Header. Besides, users can select font of table header and set the font size. By pressing Default button at any page, users can set up all the parameter at every page as the default value. NOTE: This software is mainly available for the paper specification of A4 and B5. When choosing other paper specification, users may meet some troubles. For the best effect,
Hotline: 86-010-51290405 29 Fax: 86-010-51290406

Operation manual of rebar test data processing software

please use A4 specification.

(a) General page

Hotline: 86-010-51290405

(b) Header and footer page Fax: 86-010-51290406 30

Operation manual of rebar test data processing software

(c) Table header information page Fig 3.19 Print setup dialog box

11 Print preview After the user choose Print preview, the print preview interface can be appeared for you to preview its print effect.
Fig 3.20 Print preview tool bar

The toolbar of print preview interface is displayed in Fig 3.20, Each button function is the following: Print button is used to printout, which is same as Print function in main menu ; Next Page button is used to turn down the next page, when this button is gray color (inactive), that means that the current page is the last page; Prev Page button is used to turn up the previous page, when this button is gray color(inactive), that means that the current page is the first page; Two Page/One Page button is used to display two pages side by side at the same time or to display only one page; Zoom In and Zoom Out
Hotline: 86-010-51290405 31 Fax: 86-010-51290406

Operation manual of rebar test data processing software

buttons are used to zoom in or zoom out display, when this button is gray color(inactive), that means that it is impossible to zoom in or zoom out, By using the mouses left button to click on the preview interface the user can zoom in or zoom out display as well; Close button is used to exit the print preview interface and return to the main interface. 12 Print After choosing Print menu item, the print setup dialog box is appeared as shown in the fig. 3.21, the user can choose printer model in Printer, choose paper size in Paper, choose printout orientation (Portrait or Landscape) in Orientation, then press OK button to print out; or press Cancel , to give up printing.

Fig 3.21 Print setup dialog box

NOTE: This software is mainly available for A4 and B5 paper, if other paper is chosen, an abnormal print may be appeared. 13 Exit
Hotline: 86-010-51290405 32 Fax: 86-010-51290406

Operation manual of rebar test data processing software

To close currently data file and exit the program. Before exiting, if the data has been modified, a saving hint is appeared.

3.2.2 Edit menu


1. Project information

Fig 3.22 Project information setup dialog box

After the user choose Project information menu item, a dialog box is appeared as shown in fig. 3.22, the user can setup Project, Construction, Examiner, Certificate, Report No. and so on, as the setup is completed, you can press OK button to accept this input information; or press Cancel button to give up this input information. If the current project information is same as or similar to that of a saved file, the user can press Read button and choose this file
Hotline: 86-010-51290405 33 Fax: 86-010-51290406

Operation manual of rebar test data processing software

appeared in open file dialog box and press Open button, the project information of this file is read out and filled in the dialog box, the user can make a slight modification or without modification, the user press Default button to make the last saved project information read out and fill in the dialog box.

Fig. 3.23

Input date

The user can move the mouse to click the button which locates behind the Entrusting date term in the dialog box, the input date interface can be appeared as shown in the Fig. 3.23, the input method as following: 1)Using the mouse left button to click the year of the , interface(for example:2005 year) , it can be appeared as the user can press , buttons to adjust year; 2) Clicking the , buttons which locate at the two sides around the interface top, the user can adjust month, or click the month ( for example: May) position to choose month that appear in the month list; 3) Using the mouse to click date number the user can adjust date. Besides, the user can click any position beyond the date input interface, then the interface is disappeared and the date is updated. All input date position in other dialog box or interface can be appeared as shown in the fig. 3.23, the input method is same as well. 2. Remove object
Hotline: 86-010-51290405 34 Fax: 86-010-51290406

Operation manual of rebar test data processing software

This menu is used to delete the current object of the file that is listed in Object List Area, before deleting, it can be asked that whether or not to remove the current object?, if the answer is Yes to remove the object; or the answer is No to give up removing the object. Only the object is chosen in the root node of the Object List Area, this menu is active, if a measuring line or profile is chosen in sub node of the Object List Area, the menu is inactive. NOTE: After the object was removed, which cannot be recovered again, so that please pay your attention on deleting a object. When there is only one object left in the file, which cant be deleted anymore. 3. Add objects This menu is used to make some part or all objects from other file to be added to the current file, in order to manage them together.

Fig 3.24 Add object dialog box

After the user choose Add objects menu item, a dialog box is appeared
Hotline: 86-010-51290405 35 Fax: 86-010-51290406

Operation manual of rebar test data processing software

as shown in the fig. 3.24, firstly press the Browse button, from the appeared open file dialog box choose a ZRW file, then press the Open button, All objects of the file can be shown in the Objects list frame, the user can choose the objects to be added from this list( the object in blue color are pitched on), then press the Add button, so that the chosen objects are added to the current file; or press the Exit button to give up adding. Only the object is chosen in the root node of the Object List Area, this menu is active, if a measuring line or profile is chosen in sub node of the Object List Area, the menu is inactive. NOTE: This software is compatible with all ZBL-R6 series instrument, when the user add the objects please dont add objects from the different type instrument, otherwise which maybe bring out some displaying deviation. 4. Invalidate/Validate This menu is used to set the object in the Object List Area as invalid or valid. If the current object is a valid object, the selectable item in the menu appears Invalidate; if the current object is invalid, the selectable item in the menu appears Validate. Only the object is chosen in the root node of the Object List Area, this menu is active, if a measuring line or profile is chosen in sub node of the Object List Area, the menu is inactive. NOTE: As printout, saving bitmap and batch evaluation are carried out, only the valid objects at the current file are available. 5. Delete data This menu is used to delete the selected data in the Data Area. In the data area as the user choose one or more rows of data, then choose Delete data menu item, the words Are you sure to delete the selected
Hotline: 86-010-51290405 36 Fax: 86-010-51290406

Operation manual of rebar test data processing software

data? will popup, if choose the Yes button, then delete all selected data, or choose No button, to give up the deleting operation. When the user choose a sub node(measuring line or profile) from Object List Area, then choose the data row from Data Area, this menu item is active, otherwise it is inactive. NOTE: After the data was removed, which cannot be recovered again, so that please pay your attention on deleting data. When there is the last row data in the current measuring line, which cant be deleted anymore. 6. Add data This menu is used to add some measuring point data behind the final measuring point data in the current measuring line(or profile). After the user choose the Add data menu item, a dialog box is appeared as shown in the fig. 3.25, after input the data number of rows (measure point number) to be added, then press the OK button, some blank rows are appeared behind the final data , the user can input the data.

Fig 3.25 Data number of rows dialog box

Only as the user choose a sub node(measuring line or profile) from Object List Area and the current focus is Data Area , this menu item is active, otherwise it is inactive. 7. Insert data This menu is used to insert some measuring point data before the current measuring point data in the current measuring line(or profile).
Hotline: 86-010-51290405 37 Fax: 86-010-51290406

Operation manual of rebar test data processing software

After the user choose the Insert data menu item, a dialog box is appeared as shown in the fig. 3.25, after input the data number of rows (measure point number) to be inserted, then press the OK button, some blank rows are appeared before the current data , the user can input the data. Only as the user choose a sub node(measuring line or profile) from Object List Area, then choose a data row from Data Area , this menu item is active, otherwise it is inactive. 8. Extract profile This menu is used to extract the current measuring line(or profile) from the current object to become a new object and insert that behind the last object. After user choose a measuring line or profile from Object List Area, then choose Extract profile menu item to extract. Only as the user choose a sub node(measuring line or profile) from Object List Area, this menu item is active, if a object ( root node)is chosen from Object List Area , the menu is inactive. 9. Remove profile This menu is used to remove the current measuring line (or profile) from the current object. In the Object List Area as the user choose a measuring line or a profile, then choose Remove profile menu item, the words Are you sure to delete the current profile or line? will popup, if choose the Yes button, then delete the current profile or measuring line, or choose No button, to give up the deleting operation. When the user choose a sub node (measuring line or profile) from Object List Area, this menu item is active, if the user choose a root node (measuring line or profile) from Object List Area, this menu is inactive.
Hotline: 86-010-51290405 38 Fax: 86-010-51290406

Operation manual of rebar test data processing software

NOTE: After the profile was removed, which cannot be recovered again, so that please pay your attention on deleting a profile. When there is only one measuring line or profile left, which cant be deleted anymore. 10. Depth correction

Fig 3.26 Depth correction dialog box

When the depth of the rebar cover is smaller than the minimum measuring range, by adding a mat, the measurement can be carried out, when the user carry out the data process, firstly, the mat depth should be reduced from the measuring depth. After the user choose Depth correction menu item, a dialog box is appeared as shown in fig.3.26, the user choose the object to be corrected( Current object or All objects), after inputting the Depth, then press OK button to make all measurement point depth of cover for the object to add the inputting correct depth. Or press Cancel button to give up the correction. 11. Options After the user choose Options menu item, a dialog box is appeared as shown in fig. 3.27, the user can setup Evaluation Rules option and so on, after the setup is completed, the user press OK button to accept the setup; or press Cancel button to give up the setup. Evaluation Rules is used to setup the covers positive and negative deviation tolerance for various object type. The setup for Max. and
Hotline: 86-010-51290405 39 Fax: 86-010-51290406

Operation manual of rebar test data processing software

Min. depth of Y-axis is used to control plot portrait proportion, the Y axis maximum depth cant be less than the maximum depth of all measuring point depth of all objects, Y axis minimum depth cant be bigger than the minimum depth of all measuring point depth of all objects.

Fig 3.27 Option dialog box

If the option of current file is same as or similar with that of the other saved file, press Read button, the user can choose this file from the open file dialog box, then press Open button, the option of this file is read out and filled into the dialog box, the user can make a little
Hotline: 86-010-51290405 40 Fax: 86-010-51290406

Operation manual of rebar test data processing software

modification or without any modification. To press Default button, so the previous saved option is read out and filled into the dialog box.

3.2.3 View menu


1. Object information The user can choose Object info. menu item to hide or display the object information area. The user either can make a tick at the front of this menu item to display object information area, or to hide object information. 2. Batch evaluation result

Fig 3.28 Batch Evaluation result dialog box

The user can choose Batch evaluation result menu item, a dialog box is appeared as shown in the fig.3.28 to display the batch evaluation result. Each result display format is expressed as xx/yy, among the format, the numerator is displayed as evaluation results in X direction scanning of all valid objects, the denominator is displayed as evaluation results in Y direction scanning of all valid objects. If the batch evaluation is not carried out, the menu item is inactive. 3. Bar depth The user can choose Bar depth menu item to hide or display every measuring point depth of cover at the graph area. The user can either
Hotline: 86-010-51290405 41 Fax: 86-010-51290406

Operation manual of rebar test data processing software

make a tick at the front of this menu item to display the depth of cover, or hide the depth of cover. 4. Toolbar This menu is mainly used to hide or display the toolbar, the system default status is to display the toolbar (at the front of the menu item there is a to express displaying, without a to express hide). 5. Status bar This menu is mainly used to hide or display status bar, system default state is display the status bar (at the front of the menu item have express display, not have express hide).

3.2.4 Evaluation menu


1. Single evaluation After the user choose Single menu item, the user can carry out the evaluation according to the beforehand set parameter on all object according as a single object, and update the result. NOTE: When the parameter related to the evaluation is changed, the user should re-evaluate over the object by the menu. 2. Batch evluation After the user choose Batch menu item, the user can carry out evaluation according to the beforehand set parameter on all objects as a batch and update the result. NOTE: When the parameter related to the evaluation is changed, the user should re-evaluate over the object by the menu.
Hotline: 86-010-51290405 42 Fax: 86-010-51290406

Operation manual of rebar test data processing software

3.2.5 Tools menu


1. Data transmission After the measurement completion, the user can use this menu function to make the measuring data stored in the instrument transfer to a computer in order to carry out evaluation and keep them in a archive file. The procedure is as following: 1) To connect the rebar scanners USB port with a computers USB port by using the special transmission line NOTE:Before connection it is better to switch off the rebar scanner, not to do Hot plug, otherwise it maybe cause the instrument to be damaged. As connection the transmission line to a computer at the first time, computer can check and find a new hardware, and need to install a driver, the detail operation is shown in the Appendix. 2) Running the rebar measurement data processing software under the WINDOWS environment, the user can choose Data transmission menu item, a dialog box can be appeared as shown in the fig. 3.29. The user can set the model of rebar scanner and choose transmission port (the common default is USB), then press Transmit button, a save as dialog box is appeared as shown in the fig.3.30, the user can input a filename and then press OK button. After that, the computer start to connect with the rebar scanner and the message window displays Initial complete!, the computer is waiting for the transmission data from a rebar scanner, or the user press Exit to exit the transmission function.

Hotline: 86-010-51290405

43

Fax: 86-010-51290406

Operation manual of rebar test data processing software

Fig3.29 Data transmission dialog box

Fig.3.30 Save as dialog box

3) When the user choose the Data Output item in the main menu of the rebar scanner and press Enterkey to enter into the data transmission interface, then press Enter key again to start the
Hotline: 86-010-51290405 44 Fax: 86-010-51290406

Operation manual of rebar test data processing software

measuring data transmission. Upon the data transmission is completed, the data transmission dialog box (fig.3.29) is automatically disappeared and the rebar scanner return to its main menu interface. The operation on the rebar scanner is explained in the corresponding chapter in the manual. NOTE: During data transmission, some correlation message is displayed in the Message box. If the transmission fail or some other error bring out, the system can give the corresponding hints.

3.2.6 Language menu


1. Simplified Chinese Therere two edition, simplified Chinese and English edition, of this software. If choose this menu, the user can change to simplified Chinese edition. If the current edition is simplified Chinese, then this menu is inactive. 2. English Therere two edition, simplified Chinese and English edition, of this software. If choose this menu, the user can change to English edition. If the current edition is English, then this menu is inactive.

3.2.7 Help menu


1. Help topics The menu mainly offer the help for software operation, when the user meets the problem in using the data process software, the user can choose this item or F1 key, then press Contents or Index to find out the solution in the appeared window.
Hotline: 86-010-51290405 45 Fax: 86-010-51290406

Operation manual of rebar test data processing software

2. ZBL Homepage After choosing this menu item, the user can interlink to our company internet Web homepage to know our company better. 3. E-mail to ZBL After choosing this menu item, the user can use Outlook to send an E-mail to our company to give us the feedback idea timely. 4. About The menu to display company name, software name and version etc.

Hotline: 86-010-51290405

46

Fax: 86-010-51290406

Operation manual of rebar test data processing software

Appendix The installation of USB driver


All R6 series rebar scanners manufactured by our company use the USB port to carry out the data transmission. When the user to carry out data transmission at the first time and the computer without corresponding driver software installed before, first of all, the user must install USB driver, otherwise the data transmission cant be carried out. Before the user begin to install USB driver, the user must get USB driver supplied by our company at first. The driver software can come from two ways: one way is the CD or U-disk attached by our company as the user purchase our product, there is a corresponding driver program; the other way is from our company internet web Download CenterTools page to download USB driver (this driver is an compressed file). If the user install the driver with a CD ROM, who should put the driver CD into the CD-ROM,and find the USB Driver folder under the root of CD, then enter into the folder and run the UsbSetup.exe, then operate according to the hints step by step, the driver software will be install on the computer automatically. If you download driver from network, please unzip this driver file at first to some folder of the computer, then enter the folder and run the UsbSetup.exe. NOTE: If you have installed the USB driver of our other instruments, such as Digital Rebounder, Floor Thickness Tester, etc., you have no need to install the driver software again, because they have no difference between each other completely.

Hotline: 86-010-51290405

47

Fax: 86-010-51290406

Operation manual of rebar test data processing software

Beijing ZBL Science & Technology Co., Ltd. Hotline: 010-51290405/0406 Fax: 010-51290406 E-mail: zbl@zbl.cn URL: http://www.zbl.cn Version: Ver4.2-20120710

Hotline: 86-010-51290405

48

Fax: 86-010-51290406