You are on page 1of 73

TECHNICAL MANU

AL
MANUAL
GPH 13 SEER
Package Heat Pump Units
With R-22
Refer to Service Manual RS6300009 (Horizontal) and RS6300010 (Multi Position) for installation,
operation, and troubleshooting information.

All safety information must be followed as provided in the Service Manual.


Refer to the appropriate Parts Catalog for part number information.
Models listed on page 3.

This manual is to be used by qualified, professionally trained HVAC technicians only.


Goodman does not assume any responsibility for property damage or personal injury due to
improper service procedures or services performed by an unqualified person.
Copyright 2006-2010 Goodman Manufacturing Company, L.P.

RT6332003r11
September 2010

PRODUCT IDENTIFICATION
The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please
use these numbers when requesting service or parts information.

13 24

Brand

A
Minor
Revision

G: Goodman
Refrigerant

D: Distinctions

2 - R-22
4 - R-410
Product Type
Package Unit

A: Initial
Revision
Major
Revision
A: Initial
Revision

Product Family

Voltage

H - Heat Pump

1: 208-230V/1ph/60Hz
3: 208-230V/3ph/60 Hz
4: 460V/3ph/60 Hz

Product Series
Configuration
SEER Rating

H - Horizontal
M- Multi-position
Nominal Capacity
24:
30:
36:
42:
48:
60:

WARNING

24,000 BTUH
30,000 BTUH
36,000 BTUH
42,000 BTUH
48,000 BTUH
60,000 BTUH

HIGH VOLTAGE!
Disconnect ALL power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal
injury or death.

Goodman will not be responsible


for any injury or property damage
arising from improper service or service procedures. If
you install or perform service on this unit, you assume
responsibility for any personal injury or property damage
which may result. Many jurisdictions require a license to
install or service heating and air conditioning equipment.

WARNING

WARNING

Installation and repair of this unit


should be performed ONLY by
individuals meeting (at a minimum) the requirements of
an "entry level technician" as specified by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI). Attempting to install or repair this unit without such background may result in product damage, personal injury or
death.

PRODUCT IDENTIFICATION
The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please
use these numbers when requesting service or parts information.

GPH1324H21*
GPH1330H21*

GPH1324M21*
GPH1330M21*

GPH1342H21*

GPH1336M21*
GPH1348M21*

GPH1348H21*

GPH1360M21*

GPH1336H21*

GPH1360H21*

WARNING

The United States Environmental Protection Agency (EPA) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow
these regulations may harm the environment and can lead to the imposition of substantial fines.
These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office.

Do not connect or use any device


that is not design certified by
Goodman for use with this unit.
Serious property damage, personal injury, reduced unit
performance and/or hazardous conditions may result
from the use of such non-approved devices.

WARNING

To prevent the risk of property


damage, personal injury, or death,
do not store combustible materials or use gasoline or
other flammable liquids or vapors in the vicinity of this
appliance.

WARNING

PRODUCT DESIGN
GPH Package Units are designed for outdoor installations
only in either residential or light commercial applications.
The connecting ductwork (Supply and Return) can only be
connected for horizontal airflow.
A return air filter must be installed behind the return air grille(s)
or provision must be made for a filter in an accessible location within the return air duct. The minimum filter area should
not be less than those sizes listed in the Specification Section. Under no circumstances should the unit be operated
without return air filters.

Package Heat Pump indoor sections are designed to accept


optional components such as auxiliary electric heaters and
circuit breakers. Provisions for these components have been
made at time of manufacture.
Location and Clearances
NOTE: To ensure proper condensate drainage, unit must be
installed in a level position.

A 3/4" pipe is provided for removal of condensate water from


the indoor coil. In order to provide proper condensate flow, a
drain trap is supplied and shipped loose inside the unit for
field installation. (Do not reduce the drain line size).
Refrigerant flow control is achieved by use of restrictor orifices.
Package Heat Pump models use a combination of restrictor
orifices and thermostatic expansion valves for refrigerant flow
control.
Some heat pump models also have a suction line accumulator installed between the reversing valve and the compressor.
The object of the accumulator is to:
1. Provide a liquid refrigerant storage vessel during prolonged
system off cycles.
2. Store excess liquid refrigerant not needed by the system
while running.
3. Return oil and saturated vapor to the compressor at a
controlled rate.
4. Retain stored excess refrigerant during a sudden system
pressure fluctuation such as seen in defrost cycles.

Outside Slab Installation - Horizontal (H)

Refrigerant flow control is achieved by use of restrictor orifices. GPH units use the FasTest Access Fitting System,
with a saddle that is either soldered to the suction and liquid
lines or is fastened with a locking nut to the access fitting
box (core) and then screwed into the saddle. NOTE: The
core must not be removed from the saddle until the
refrigerant charge has been removed. Failure to do so
could result in property damage or personal injury.
The single phase units use permanent split capacitor (PSC)
design compressors. Starting components are not required
for these units. A low microfarad run capacitor assists the
compressor to start and remains in the circuit during operation.
The outdoor fan and indoor blower motors are single phase
capacitor type motors. GPH1360H21* units have X-13 indoor
blower motors that are energized by a 24V signal from the
IBR and are constant torque motors with very low power consumption. The X-13 features an integral control module.
Air for condensing (cooling cycle) or evaporation (heating
cycle) is drawn through the outdoor coil by a propeller fan,
and is discharged vertically out the top of the unit. The outdoor coil is designed for .0 static. No additional restriction
(ductwork) shall be applied.
Conditioned air is drawn through the filter(s), field installed,
across the coil and back into the conditioned space by the
indoor blower.

48" MIN

12" MIN

36" MIN
(FOR
SERVICE)

3"
MIN

12" MIN
36" MIN
(FOR SERVICE)

Outside Slab Installation -Multi-positional (M)


NOTE: Roof overhang should be no more than 36" and provisions made to deflect the warm discharge air out from the
overhang.
Minimum clearances are required to avoid air recirculation
and keep the unit operating at peak efficiency.

PRODUCT DESIGN
In installations where the unit is installed above ground level
and not serviceable from the ground (Example: roof top installations) the installer must provide service platform for service person with rails or guards in accordance with local codes
or ordinances, or, in their absence, with the latest edition of
the Uniform Mechanical Code Section 305.

36"

UN
IT

NOTE: Unit can also use roof curb (and platform for leveling,
where necessary) to utilize bottom discharge.

PL
EN
UM
24"

WARNING
PL

AT
FO
RM

RB
CU

36"

Rooftop Installation - Horizontal (H)

TO PREVENT POSSIBLE PROPERTY DAMAGE, THE


UNIT SHOULD REMAIN IN AN UPRIGHT POSITION
DURING ALL RIGGING AND MOVING OPERATIONS.
TO FACILITATE LIFTING AND MOVING IF A CRANE IS
USED, PLACE THE UNIT IN AN ADEQUATE CABLE
SLING.
IMPORTANT: If using bottom discharge with roof curb,
ductwork should be attached to the curb prior to installing
the unit.
Refer to Roof curb Installation Instructions for proper curb
installation. Curbing must be installed in compliance with the
National Roofing Contractors Association Manual.

Roof Curb

Rooftop Installation - -Multi-positional (M)


NOTE: To ensure proper condensate drainage, unit must be
installed in a level position.

PRODUCT DESIGN

GPH1324-1360H21*

ELECTRICAL DATA (*Blower Only, Heat Mode)


Circuit #1

Circuit #2

Minimum Circuit
Ampacity
at 208 / 240V

Maximum
Overcurrent
Protection (amps)
at 208 / 240V

Minimum Circuit
Ampacity
at 208 / 240V

Maximum
Overcurrent
Protection (amps)
at 208 / 240V

Actual
kW & BTU
at 240V

GPH1324H21* / *B / *C
HKR05A,CA
HKR08A,CA
HKR10A,CA

24 / 27
33 / 28
45 / 51

30 / 30
40 / 40
60 / 60

----------

----------

4.75 / 16,200
7.00 / 23,800
9.50 / 32,400

GPH1330H21* / *B / *C
HKR05A,CA
HKR08A,CA
HKR10A,CA
HKR15A,CA

24 / 27
34 / 39
45 / 52
45 / 52

30 / 30
40 / 40
60 / 60
60 / 60

---------22 / 25

---------30 / 30

4.75 / 16,200
7.00 / 23,800
9.50 / 32,400
14.25 / 48,600

GPH1336H21* / *B / *C / *D
HKR05A,CA
HKR08A,CA
HKR10A,CA
HKR15A,CA

24 / 27
34 / 39
45 / 52
45 / 52

30 / 30
40 / 40
60 / 60
60 / 60

---------22 / 25

---------30 / 30

4.75 / 16,200
7.00 / 23,800
9.50 / 32,400
14.25 / 48,600

GPH1342H21* / *B / *C / *D
HKR05A,CA
HKR08A,CA
HKR10A,CA
HKR15A,CA
HKR20A,CA

25 / 27
34 / 39
46 / 52
46 / 52
46 / 52

30 / 30
40 / 40
60 / 60
60 / 60
60 / 60

---------22 / 25
43 / 49

---------30 / 30
60 / 60

4.75 / 16,200
7.00 / 23,800
9.50 / 32,400
14.25 / 48,600
19.50 / 66,500

GPH1348H21* / *B / *C
HKR05A,CA
HKR08A,CA
HKR10A,CA
HKR15A,CA
HKR20A,CA

25 / 28
34 / 40
46 / 53
46 / 52
46 / 52

30 / 30
40 / 40
60 / 60
60 / 60
60 / 60

---------22 / 25
43 / 49

---------30 / 30
60 / 60

4.75 / 16,200
7.00 / 23,800
9.50 / 32,400
14.25 / 48,600
19.50 / 66,500

GPH1360H21* / *B / *C
HKR05A,CA
HKR08A,CA
HKR10A,CA
HKR15A,CA
HKR20A,CA

26 / 30
36 / 40
48 / 54
48 / 54
48 / 54

30 / 30
40 / 40
60 / 60
60 / 60
60 / 60

---------22 / 25
43 / 49

---------30 / 30
60 / 60

4.75 / 16,200
7.00 / 23,800
9.50 / 32,400
14.25 / 48,600
19.50 / 66,500

Model and Heat Kit Usage

IMPORTANT NOTE: A separate power supply is required for the HKR heater kit.

WARNING

All wires and overcurrent protection devices are sized for use with electric heaters only and without
refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See
PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent
protection during refrigeration cycle.

PRODUCT DESIGN

GPH1324-1360M21*

ELECTRICAL DATA (*Blower Only, Heat Mode)


Circuit #1

Circuit #2

Minimum Circuit
Ampacity
at 208 / 240V

Maximum
Overcurrent
Protection (amps)
at 208 / 240V

Minimum Circuit
Ampacity
at 208 / 240V

Maximum
Overcurrent
Protection (amps)
at 208 / 240V

Actual
kW & BTU
at 240V

GPH1324M21* / A* / *B
HKR05A,CA
HKR08A,CA
HKR10A,CA

24 / 27
33 / 28
45 / 51

30 / 30
40 / 40
60 / 60

----------

----------

4.75 / 16,200
7.00 / 23,800
9.50 / 32,400

GPH1330M21* / A* / *B
HKR05A,CA
HKR08A,CA
HKR10A,CA
HKR15A,CA

24 / 27
33 / 28
45 / 51
45 / 52

30 / 30
40 / 40
60 / 60
60 / 60

---------22 / 25

---------30 / 30

4.75 / 16,200
7.00 / 23,800
9.50 / 32,400
14.25 / 48,600

GPH1336M21* / A* / *B
HKR05A,CA
HKR08A,CA
HKR10A,CA
HKR15A,CA

24 / 27
34 / 39
45 / 52
45 / 52

30 / 30
40 / 40
60 / 60
60 / 60

---------22 / 25

---------30 / 30

4.75 / 16,200
7.00 / 23,800
9.50 / 32,400
14.25 / 48,600

GPH1348M21* / A* / *B
HKR05A,CA
HKR08A,CA
HKR10A,CA
HKR15A,CA
HKR20A,CA

25 / 28
34 / 40
46 / 53
46 / 52
46 / 52

30 / 30
40 / 40
60 / 60
60 / 60
60 / 60

---------22 / 25
43 / 49

---------30 / 30
60 / 60

4.75 / 16,200
7.00 / 23,800
9.50 / 32,400
14.25 / 48,600
19.50 / 66,500

GPH1360M21* / A* / *B
HKR05A,CA
HKR08A,CA
HKR10A,CA
HKR15A,CA
HKR20A,CA

26 / 30
36 / 40
48 / 54
48 / 54
48 / 54

30 / 30
40 / 40
60 / 60
60 / 60
60 / 60

---------22 / 25
43 / 49

---------30 / 30
60 / 60

4.75 / 16,200
7.00 / 23,800
9.50 / 32,400
14.25 / 48,600
19.50 / 66,500

Model and Heat Kit Usage

IMPORTANT NOTE: A separate power supply is required for the HKR heater kit.

WARNING

All wires and overcurrent protection devices are sized for use with electric heaters only and without
refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See
PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent
protection during refrigeration cycle.

PRODUCT DIMENSIONS

GPH1324-60]H21*

A
14.000

4.512

4.500

14.000
SUPPLY

6.500

14.000
RETURN

BACK VIEW
(DUCT OPENINGS)
66.542

34.075

Chassis

Model

GPH1324H21*

22.000

29.932

GPH1330H21*

22.000

29.932

GPH1336H21*

24.000

34.932

GPH1342H21*

24.000

34.932

GPH1348H21*

24.000

38.682

GPH1360H21*

24.000

38.682

Small

Medium

Large

PRODUCT DIMENSIONS

GPH1324-60]M21*

47

51

POWER
WIRE
ENTRANCE
4 1/8
2 1/8

16
1 3/8

A?

16
6

B
8

2 34

RETURN

B?

SUCTION/LIQUID
PRESSURE PORT

SUPPLY
3

CONDENSATE
DRAIN
CONNECTION
3/4 NPT FEMALE

18 7/8

CONTROL
WIRE
ENTRANCE

BLOWER
ACCESS PANEL

MEDIUM CHASSIS
GPH1324M21*
GPH1330M21*
GPH1336M21*
LARGE CHASSIS
GPH1348M21*
GPH1360M21*

PACKAGE HEAT PUMP SPECIFICATIONS

GPH13[24-30]H21*

GPH1324H21
A*

GPH1324H21
AD

GPH1330H21
A*

GPH1330H21
AD
28,600

COOLING

COOLING CAPACITY, BTUH

25,000

24,000

28,600

CAPACITY

13.00

13.00

13.00

13.00

HEATING

SEER
47/43F

24,000

24,000

27,400

27,400

RATING

35/33F

17,600

17,600

20,400

20,400

17/15F

13,600

13,600

15,800

15,800

7.7

7.7

7.7

7.7

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

16.2

16.2

15.7

15.7

19.6

19.6

18.7

18.7

30

30

30

30

SCROLL

SCROLL

SCROLL

SCROLL

13.6

13.6

12.2

12.2

63

63

67

67

HSPF
UNIT

VOLTAGE (NAMEPLATE)

ELECTRICAL

AMPS

SPECIFICATION

MIN CIRCUIT AMPACITY


(2)

MAX OVERCURRENT PROTECTION


COMPRESSOR

TYPE
RATED LOAD AMPS
LOCKED ROTOR AMPS

CONDENSER

HORSEPOWER

1/6

1/6

1/6

1/6

FAN MOTOR

RPM

840

840

840

840

FULL LOAD AMPS

1.1

1.1

1.1

1.1

LOCKED ROTOR AMPS

1.7

1.7

1.7

1.7

CONDENSER FAN

BLADE DIAMETER (INCHES) / NUMBER OF BLADES

22 / 3

22 / 3

22 / 3

22 / 3

CONDENSER

FACE AREA (SQ. FT.)

15.2

13.4

14.6

14.2

COIL

NUMBER OF ROWS

FINS PER INCH

19

24

16

22

1/4 - 3

1/4 - 3

1/3 - 3

1/3 - 3

1.5

1.5

2.4

2.4

2.2
MEDIUM

2.2
MEDIUM

3.2
LOW

3.2
LOW

RPM

1,075

1,075

1,075

1,075

EVAPORATOR

DIAMETER X WIDTH (INCHES)

9x6

9x6

9 x6

9x6

BLOWER

RATED SCFM COOLING

815

815

1080

1080

EVAPORATOR

HORSEPOWER - NO. OF SPEEDS

BLOWER

FULL LOAD AMPS

MOTOR

LOCKED ROTOR AMPS


MOTOR SPEED TAP - COOLING

MAX EXTERNAL STATIC PRESS ("w.c.)

0.5

0.5

0.5

0.5

EVAPORATOR

FACE AREA (SQ. FT.)

4.6

4.6

4.6

4.6

COIL

NUMBER OF ROWS

FINS PER INCH

14

14

14

14

20 x 20 x 1

20 x 20 x 1

20 x 25 x 1

20 x 25 x 1

GENERAL

FILTER SIZE (SQ. FT.)

INFORMATION

DRAIN SIZE (INCHES)

3/4"

3/4"

3/4"

3/4"

EXPANSION DEVICE

ORIFICE

ORIFICE

ORIFICE

ORIFICE

102

94

146

115

3/4, 1, 1-1/4

3/4, 1, 1-1/4

3/4, 1, 1-1/4

3/4, 1, 1-1/4

1/2

1/2

1/2

1/2

7 / 25

7 / 25

7 / 25

7 / 25

REFRIGERANT CHARGE R-22 (OZS.)


POWER SUPPLY CONDUIT KNOCKOUT SIZE (INCHES)
LOW VOLTAGE CONDUIT KNOCKOUT SIZE (INCHES)
PRESSURE SWITCH - OPENS / CLOSES PSIG
SHIPPING WEIGHT (LBS.)

325

326

325

325

OPERATING WEIGHT (LBS.)

315

316

315

315

(2)
*

Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
Calculated external filter size based on air velocity of 300 ft/min.

Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.
IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers
in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters.

10

PACKAGE HEAT PUMP SPECIFICATIONS

GPH1336H21*

GPH1336H21
A/AB

GPH1336H21
AC/AD

GPH1336H21
AE
35,000

COOLING

COOLING CAPACITY, BTUH

35,000

35,000

CAPACITY

13.00

13.00

13.00

HEATING

SEER
47/43F

33,600

33,600

33,600

RATING

35/33F

27,000

27,000

27,000

17/15F

18,000

18,000

18,000

HSPF

7.7

7.7

7.7

208/230-60-1

208/230-60-1

208/230-60-1

AMPS

18.5

18.5

18.5

MIN CIRCUIT AMPACITY

22.1

22.1

22.1

30

30

30

RECIP

RECIP

RECIP

14.5

14.5

14.5

LOCKED ROTOR AMPS

82

82

82

CONDENSER

HORSEPOWER

1/4

1/4

1/4

FAN MOTOR

RPM

1075

830

830

FULL LOAD AMPS

1.4

1.5

1.5

LOCKED ROTOR AMPS

2.9

3.0

3.0

UNIT

VOLTAGE (NAMEPLATE)

ELECTRICAL
SPECIFICATION

MAX OVERCURRENT PROTECTION


COMPRESSOR

TYPE
RATED LOAD AMPS

CONDENSER FAN

BLADE DIAMETER (INCHES) / NUMBER OF BLADES

22 / 3

22 / 4

22 / 4

CONDENSER

FACE AREA (SQ. FT.)

16.1

16.1

17

COIL

NUMBER OF ROWS

FINS PER INCH

16

16

22

1/3 - 3

1/3 - 3

1/3 - 3

2.4

2.4

2.4

3.2
MEDIUM

3.2
MEDIUM

3.2
MEDIUM
1,075

EVAPORATOR

HORSEPOWER - NO. OF SPEEDS

BLOWER

FULL LOAD AMPS

MOTOR

LOCKED ROTOR AMPS


MOTOR SPEED TAP - COOLING
RPM

1,075

1,075

EVAPORATOR

DIAMETER X WIDTH (INCHES)

9x8

9x8

9x8

BLOWER

RATED SCFM COOLING

1205

1205

1205

MAX EXTERNAL STATIC PRESS ("w.c.)

0.5

0.5

0.5

EVAPORATOR

FACE AREA (SQ. FT.)

6.2

6.2

6.2

COIL

NUMBER OF ROWS

FINS PER INCH

14

14

14

25 x 25 x 1

25 x 25 x 1

25 x 25 x 1

GENERAL

FILTER SIZE (SQ. FT.)

INFORMATION

DRAIN SIZE (INCHES)

3/4"

3/4"

3/4"

EXPANSION DEVICE

ORIFICE

ORIFICE

ORIFICE

164

164

145

3/4, 1, 1-1/4

3/4, 1, 1-1/4

3/4, 1, 1-1/4

1/2

1/2

1/2

7 / 25

7 / 25

7 / 25

SHIPPING WEIGHT (LBS.)

385

385

385

OPERATING WEIGHT (LBS.)

375

375

375

REFRIGERANT CHARGE R-22 (OZS.)


POWER SUPPLY CONDUIT KNOCKOUT SIZE (INCHES)
LOW VOLTAGE CONDUIT KNOCKOUT SIZE (INCHES)
PRESSURE SWITCH - OPENS / CLOSES PSIG

(2)
*

Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
Calculated external filter size based on air velocity of 300 ft/min.

Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.
IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers
in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters.

11

PACKAGE HEAT PUMP SPECIFICATIONS

GPH1342H21*

GPH1342H21
A/AB

GPH1342H21
AC/AD

GPH1342H21
AE
41,000

COOLING

COOLING CAPACITY, BTUH

41,000

41,000

CAPACITY

SEER

13.00

13.00

13.00

HEATING

47/43F

38,000

38,000

38,000

RATING

35/33F

30,000

30,000

30,000

17/15F

21,800

21,800

21,800

7.8

7.8

7.8

208/230-60-1

208/230-60-1

208/230-60-1

HSPF
UNIT

VOLTAGE (NAMEPLATE)

ELECTRICAL

AMPS

SPECIFICATION

MIN CIRCUIT AMPACITY

22

22

22

26.1

26.1

26.1

40

40

40

SCROLL

SCROLL

SCROLL

16.5

16.5

16.5

LOCKED ROTOR AMPS

95

95

95

CONDENSER

HORSEPOWER

1/4

1/4

1/4

FAN MOTOR

RPM

1075

830

830

FULL LOAD AMPS

1.4

1.5

1.5

LOCKED ROTOR AMPS

2.9

3.0

3.0

MAX OVERCURRENT PROTECTION


COMPRESSOR

TYPE
RATED LOAD AMPS

CONDENSER FAN

BLADE DIAMETER (INCHES) / NUMBER OF BLADES

22 / 3

22 / 4

22 / 4

CONDENSER

FACE AREA (SQ. FT.)

17.2

17.2

17.2

COIL

NUMBER OF ROWS

FINS PER INCH

16

16

24

EVAPORATOR

HORSEPOWER - NUMBER OF SPEEDS

1/2 - 3

1/2 - 3

1/2 - 3

BLOWER

FULL LOAD AMPS

3.9

3.9

3.9

MOTOR

LOCKED ROTOR AMPS

4.9

4.9

4.9

MEDIUM

MEDIUM

MEDIUM

MOTOR SPEED TAP - COOLING


RPM

1,075

1,075

1,075

EVAPORATOR

DIAMETER X WIDTH (INCHES)

10 x 8

10 x 8

10 x 8

BLOWER

RATED SCFM COOLING

1,410

1,410

1,410

MAX EXTERNAL STATIC PRESS ("w.c.)

0.5

0.5

0.5

EVAPORATOR

FACE AREA (SQ. FT.)

6.2

6.2

6.2

COIL

NUMBER OF ROWS

FINS PER INCH

14

14

14
(2) 20 x 20 x 1

GENERAL

FILTER SIZE (SQ. FT.)*

(2) 20 x 20 x 1

(2) 20 x 20 x 1

INFORMATION

DRAIN SIZE (INCHES)

3/4"

3/4"

3/4"

EXPANSION DEVICE

ORIFICE

ORIFICE

ORIFICE

REFRIGERANT CHARGE R-22 (OZS.)


POWER SUPPLY CONDUIT KNOCKOUT SIZE (INCHES)
LOW VOLTAGE CONDUIT KNOCKOUT SIZE (INCHES)

168

168

137

3/4, 1, 1-1/4

3/4, 1, 1-1/4

3/4, 1, 1-1/4

1/2

1/2

1/2

7 / 25

7 / 25

7 / 25

SHIPPING WEIGHT (LBS.)

385

385

385

OPERATING WEIGHT (LBS.)

375

375

375

PRESSURE SWITCH - OPENS / CLOSES PSIG

(2)
*

Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
Calculated external filter size based on air velocity of 300 ft/min.

Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.
IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers
in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters.

12

PACKAGE HEAT PUMP SPECIFICATIONS

GPH13[48-60]H21*

GPH1348H21
A*

GPH1348H21
AD

GPH1360H21
A*

GPH1360H21
AD
57,500

COOLING

COOLING CAPACITY, BTUH

46,400

46,000

57,600

CAPACITY

SEER

13.00

13.00

13.00

13.00

HEATING

47/43F

45,000

45,000

54,400

54,000

RATING

35/33F

33,000

33,000

39,000

39,000

17/15F

23,200

23,200

29,400

29,400

HSPF

7.7

7.7

7.7

7.7

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

UNIT

VOLTAGE (NAMEPLATE)

ELECTRICAL

AMPS

26.7

22.6

33.4

32.2

SPECIFICATION

MIN CIRCUIT AMPACITY

31.9

27.1

39.8

38.5

MAX OVERCURRENT PROTECTION

50

45

60

60

SCROLL

SCROLL

SCROLL

SCROLL

RATED LOAD AMPS

20.4

18.3

25.0

25.0

LOCKED ROTOR AMPS

109

109

148

148

CONDENSER

HORSEPOWER

1/3

1/4

1/3

1/4

FAN MOTOR

RPM

1075

1075

1075

1075

2.4

1.4

2.4

1.4

COMPRESSOR

TYPE

FULL LOAD AMPS


LOCKED ROTOR AMPS
CONDENSER FAN

BLADE DIAMETER (INCHES) / NUMBER OF BLADES

CONDENSER

FACE AREA (SQ. FT.)

COIL

NUMBER OF ROWS
FINS PER INCH

5.2

2.9

5.2

2.9

22 / 4

22 / 4

22 / 4

22 / 4

19.1

19.1

19.1

19.1

16

16

16

16

1/2 - 3

1/2 - 3

3/4 -3

3/4 -5

EVAPORATOR

HORSEPOWER - NUMBER OF SPEEDS

BLOWER

FULL LOAD AMPS

3.9

2.87

6.0

5.8

MOTOR

LOCKED ROTOR AMPS

4.9

4.59

8.0

NA

MOTOR SPEED TAP - COOLING

HIGH

HIGH

MEDIUM

T2

RPM

1,075

1,075

1,075

1,075

EVAPORATOR

DIAMETER X WIDTH (INCHES)

10 x 8

10 x 8

11 x 8

11 x 8

BLOWER

RATED SCFM COOLING

1,585

1,585

1,985

1,985

MAX EXTERNAL STATIC PRESS ("w.c.)

0.5

0.5

0.5

0.5

EVAPORATOR

FACE AREA (SQ. FT.)

6.2

6.2

7.0

7.0

COIL

NUMBER OF ROWS

FINS PER INCH

14

14

14

14

GENERAL

FILTER SIZE (SQ. FT.)*

(2) 20 x 20 x 1

(2) 20 x 20 x 1

(2) 20 x 25 x 1

(2) 20 x 25 x 1

INFORMATION

DRAIN SIZE (INCHES)

3/4"

3/4"

3/4"

3/4"

EXPANSION DEVICE

ORIFICE

ORIFICE

ORIFICE

ORIFICE

228

195

245

230

3/4, 1, 1-1/4

3/4, 1, 1-1/4

3/4, 1, 1-1/4

3/4, 1, 1-1/4

REFRIGERANT CHARGE R-22 (OZS.)


POWER SUPPLY CONDUIT KNOCKOUT SIZE (INCHES)
LOW VOLTAGE CONDUIT KNOCKOUT SIZE (INCHES)

1/2

1/2

1/2

1/2

7 / 25

7 / 25

7 / 25

7 / 25

SHIPPING WEIGHT (LBS.)

415

428

415

483

OPERATING WEIGHT (LBS.)

405

418

405

473

PRESSURE SWITCH - OPENS / CLOSES PSIG

(2)
*

Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
Calculated external filter size based on air velocity of 300 ft/min.

Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.
IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers
in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters.

13

PACKAGE HEAT PUMP SPECIFICATIONS GPH13[24-36]M21A*


GPH1324M21A/AA

GPH1324M21AB

GPH1330M21A/AA

GPH1330M21AB

GPH1336M21*

GPH1336M21AB
35,600

COOLING

COOLING CAPACITY, BTUH

24,000

24,000

30,000

30,000

35,600

CAPACITY

SEER
47/43F

13.00

13.00

13.00

13.00

13.00

13.00

22,000

22,000

29,200

29,200

34,200

34,200

35/33F

18,300

18,300

23,000

23,000

28,400

28,400

17/15F

12,400

12,400

16,000

16,000

18,600

18,600

7.7

7.7

7.7

7.7

7.8

7.8

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

HEATING
RATING

HSPF
UNIT

VOLTAGE (NAMEPLATE)

ELECTRICAL

AMPS

13.9

13.9

12.3

12.3

18.1

18.1

SPECIFICATION

MIN CIRCUIT AMPACITY

16.6

16.6

19.9

19.9

21.7

21.7

MAX OVERCURRENT PROTECTION


COMPRESSOR

TYPE
RATED LOAD AMPS
LOCKED ROTOR AMPS

20

20

30

30

30

30

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

10.9

10.9

13.5

13.5

14.7

14.7

54

54

73

73

83

83

CONDENSER

HORSEPOWER

1/4

1/4

1/4

1/4

1/4

1/4

FAN MOTOR

RPM

1075

830

1075

830

1075

830

FULL LOAD AMPS

1.5

1.5

1.5

1.5

1.5

1.5

LOCKED ROTOR AMPS

3.0

3.0

3.0

3.0

3.0

3.0

CONDENSER FAN

BLADE DIAMETER (INCHES)


NUMBER OF BLADES

22
3

22
3

22
3

22
3

22
3

22
3

CONDENSER

FACE AREA (SQ. FT.)

17.2

17.2

15.9

15.9

17.2

17.2

COIL

NUMBER OF ROWS

FINS PER INCH

19

19

16

16

16

16

1/4 - 3

1/4 - 3

1/3 - 3

1/3 - 3

1/3 - 4

1/3 - 4

1.5

1.5

1.5

1.5

1.9

1.9

3.2

3.2

3.5

3.5

MEDIUM

MEDIUM

LOW

LOW

MED-LOW

MED-LOW

EVAPORATOR

HORSEPOWER - NUMBER OF SPEEDS

BLOWER

FULL LOAD AMPS

MOTOR

LOCKED ROTOR AMPS


MOTOR SPEED TAP - COOLING
RPM

1,075

1,075

1,075

1,075

1,075

1,075

EVAPORATOR

DIAMETER X WIDTH (INCHES)

10 x 9

10 x 9

10 x 9

10 x 9

10 x 9

10 x 9

BLOWER

RATED SCFM COOLING

875

875

1050

1050

1,225

1,225

MAX EXTERNAL STATIC PRESS ("w.c.)

0.5

0.5

0.5

0.5

0.5

0.5

EVAPORATOR

FACE AREA (SQ. FT.)

4.5

4.5

4.5

4.5

4.5

4.5

COIL

NUMBER OF ROWS

FINS PER INCH

14

14

14

14

14

14

20 x 20 x 1

20 x 20 x 1

20 x 25 x 1

20 x 25 x 1

25 x 25 x 1

25 x 25 x 1

GENERAL

FILTER SIZE (SQ. FT.)*

INFORMATION

DRAIN SIZE (INCHES)

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

EXPANSION DEVICE

ORIFICE

ORIFICE

ORIFICE

ORIFICE

ORIFICE

ORIFICE

108

108

137

137

165

165

3/4, 1, 1-1/4

3/4, 1, 1-1/4

3/4, 1, 1-1/4

3/4, 1, 1-1/4

3/4, 1, 1-1/4

3/4, 1, 1-1/4

REFRIGERANT CHARGE R-22 (OZS.)


POWER SUPPLY
CONDUIT KNOCKOUT SIZE (INCHES)
LOW VOLTAGE
CONDUIT KNOCKOUT SIZE (INCHES)
PRESSURE SWITCH - OPENS / CLOSES PSIG

1/2

1/2

1/2

1/2

1/2

1/2

7 / 25

7 / 25

7 / 25

7 / 25

7 / 25

7 / 25

SHIPPING WEIGHT (LBS.)

376

376

410

410

438

438

OPERATING WEIGHT (LBS.)

354

354

388

388

416

416

(2)
*

Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
Calculated external filter size based on air velocity of 300 ft/min.

Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.
IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers
in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters.

14

PACKAGE HEAT PUMP SPECIFICATIONS GPH13[48-60]M21A*


GPH1348M21A/AA

GPH1348M21AB

GPH1360M21A/AA

GPH1360M21AB
56,000

COOLING

COOLING CAPACITY, BTUH

48,000

48,000

56,000

CAPACITY

SEER
47/43F

13.00

13.00

13.00

13.00

45,000

45,000

55,000

55,000

35/33F

37,400

37,400

45,700

45,700

17/15F

25,000

25,000

31,000

31,000

8.0

8.0

7.7

7.7

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

HEATING
RATING

HSPF
UNIT

VOLTAGE (NAMEPLATE)

ELECTRICAL

AMPS

26.6

26.6

35.1

35.1

SPECIFICATION

MIN CIRCUIT AMPACITY

31.2

31.2

41.4

41.4

40

40

60

60

SCROLL

SCROLL

SCROLL

SCROLL

RATED LOAD AMPS

18.3

18.3

25

25

LOCKED ROTOR AMPS

109

109

148

148

CONDENSER

HORSEPOWER

1/3

1/4

1/3

1/4

FAN MOTOR

RPM

MAX OVERCURRENT PROTECTION


COMPRESSOR

TYPE

1075

1075

1075

1075

FULL LOAD AMPS

2.4

1.4

2.4

1.4

LOCKED ROTOR AMPS

5.2

2.9

5.2

3.0

CONDENSER FAN

BLADE DIAMETER (INCHES)


NUMBER OF BLADES

22
4

22
4

22
4

22
4

CONDENSER

FACE AREA (SQ. FT.)

21.2

21.2

21.2

21.2

COIL

NUMBER OF ROWS

FINS PER INCH

16

16

18

18

EVAPORATOR

HORSEPOWER - NUMBER OF SPEEDS

3/4 -5

3/4 -5

1 -5

1 -5

BLOWER

FULL LOAD AMPS

5.8

5.8

7.6

7.6

MOTOR

LOCKED ROTOR AMPS

8.0

8.0

9.0

9.0

MOTOR SPEED TAP - COOLING

T2

T2

T2

T2

RPM

1,075

1,075

1,075

1,075

EVAPORATOR

DIAMETER X WIDTH (INCHES)

10 x 9

10 x 9

10 x 9

10 x 9

BLOWER

RATED SCFM COOLING

1,750

1,750

1,900

1,900

MAX EXTERNAL STATIC PRESS ("w.c.)

0.5

0.5

0.5

0.5

EVAPORATOR

FACE AREA (SQ. FT.)

6.2

6.2

6.2

6.2

COIL

NUMBER OF ROWS

FINS PER INCH

14

14

14

14
(2) 20 x 25 x 1

GENERAL

FILTER SIZE (SQ. FT.)*

(2) 20 x 20 x 1

(2) 20 x 20 x 1

(2) 20 x 25 x 1

INFORMATION

DRAIN SIZE (INCHES)

3/4"

3/4"

3/4"

3/4"

EXPANSION DEVICE

ORIFICE

ORIFICE

ORIFICE

ORIFICE

192

192

195

195

3/4, 1, 1-1/4

3/4, 1, 1-1/4

3/4, 1, 1-1/4

3/4, 1, 1-1/4

REFRIGERANT CHARGE R-22 (OZS.)


POWER SUPPLY
CONDUIT KNOCKOUT SIZE (INCHES)
LOW VOLTAGE
CONDUIT KNOCKOUT SIZE (INCHES)

1/2

1/2

1/2

1/2

7 / 25

7 / 25

7 / 25

7 / 25

SHIPPING WEIGHT (LBS.)

492

492

523

523

OPERATING WEIGHT (LBS.)

469

469

500

500

PRESSURE SWITCH - OPENS / CLOSES PSIG

(2)
*

Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
Calculated external filter size based on air velocity of 300 ft/min.

Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.
IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers
in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters.

15

GPH13[24-60]H21A*

ACCESSORIES

ACCESSORIES - GPC/GPH****H MODELS


Part Number

Description

OT18-60A

Outdoor Thermostat Kit w/Lockout Stat

OT/EHR18-60

Emergency Heat Relay Kit

HKR

Electric Heat Kit

PCCP101-103

Roof Curb

PCP101-103

Downflow Plenum Kit

PCP101-103R8

Downflow Plenum Kit w/ R-8 Insulation

PCEC101-103

Downflow Economizer for GPC-(H) A/C - To Be Used With PCP101-103

PCEH101-103

Downflow Economizer for GPH-(H) Heat Pump - To Be Used With PCP101-103

PCMD101-103

Manual Damper - To Be Used With PCP101-103

PCMDM101-103

Motorized Damper - To Be Used With PCP101-103

GPHMD101-103

Manual Damper for Horizontal Applications

SQRPCH101

Square to Round Adapters 16" & 14"

SQRPCH102-103

Square to Round Adapters 18" & 14"

SQRPC101

Square to Round Adapter - For Use With PCCP101-103 Curb 16" Rounds

SQRPC102-103

Square to Round Adapter For Use With PCCP101-103 Curb 18" Rounds

PCFR101-103

External Horizontal Filter Rack

PCEF101-103

Elbow & Flashing w/ R-8 Liner

CDK36

Flush Mount Concentric Duct Kit

CDK36515

Flush Mount Concentric Duct Kit w/ Filter

CDK36530

Step Down Concentric Duct Kit

CDK36535

Step Down Concentric Duct Kit w/ Filter

CDK4872

Flush Mount Concentric Duct Kit

CDK4872515

Flush Mount Concentric Duct Kit w/ Filter

CDK4872530

Step Down Concentric Duct Kit

CDK4872535

Step Down Concentric Duct Kit w/ Filter

16

GPH13[24-60]M21A*

ACCESSORIES

ACCESSORIES - GPC/GPH****M MODELS


Part Number

Description

OT18-60A

Outdoor Thermostat Kit w/Lockout Stat

OT/EHR18-60

Emergency Heat Relay Kit

HKR

Electric Heat Kit

PGC101/102/103

Roof Curb

PEHH101/102

Horizontal Economizer For Heat Pump, Small and Medium Chassis

PEHH103

Horizontal Economizer For Heat Pump, Large Chassis

PEHC101/102

Horizontal Economizer For A/C, Small and Medium Chassis

PEHC103

Horizontal Economizer For A/C, Large Chassis

PGMDD101/102

Manual 25% Fresh Air Damper Downflow Application, Small and Medium Chassis

PGMDD103

Manual 25% Fresh Air Damper Downflow Application, Large Chassis

PGMDH102

Manual 25% Fresh Air Damper Horizontal Application, Medium Chassis

PGMDH103

Manual 25% Fresh Air Damper Horizontal Application, Large Chassis

PGMDMD101/102

Motorized 25% Fresh Air Damper Downflow Application,Small and Medium Chassis

PGMDMD103

Motorized 25% Fresh Air Downflow Application, Large Chassis

PGMDMH102

Motorized 25% Fresh Air Damper Horizontal Application, Medium Chassis

PGMDMH103

Motorized 25% Fresh Air Damper Horizontal Application, Large Chassis

GPC13MED102

Downflow Economizer For A/C, Medium Chassis

GPC13MED103

Downflow Economizer For A/C, Large Chassis

GPH13MED102

Downflow Economizer For Heat Pump, Medium Chassis

GPH13MED103

Downflow Economizer For Heat Pump, Large Chassis

GPH13MFR102

Internal Filter Rack, Medium Chassis

GPH13MFR103

Internal Filter Rack, Large Chassis

GPGHFR101-103

External Horizontal Filter Rack for Goodman/Amana Gas/Electric and Multi-position Package Units All Chassis

SQRPG101/102

Square to Round Adapter w/ 16" Round Downflow Application, Medium Chassis

SQRPG103

Square to Round Adapter w/ 18" Round Downflow Application, Large Chassis

SQRPGH101/102

Square to Round Adapter w/ 16" Round Horizontal Application, Medium Chassis

SQRPGH103

Square to Round Adapter w/ 18" Round Horizontal Application, Large Chassis

CDK36

Flush Mount Concentric Duct Kit

CDK36515

Flush Mount Concentric Duct Kit w/ Filter

CDK36530

Step Down Concentric Duct Kit

CDK36535

Step Down Concentric Duct Kit w/ Filter

CDK4872

Flush Mount Concentric Duct Kit

CDK4872515

Flush Mount Concentric Duct Kit w/ Filter

CDK4872530

Step Down Concentric Duct Kit

CDK4872535

Step Down Concentric Duct Kit w/ Filter

17

GPH13[24-60]H21*

BLOWER PERFORMANCE DATA


Speed
LOW

GPH1360H21*

GPH1348H21*

GPH1342H21*

GPH1336H21*

GPH1330H21*

Model
GPH1324H21*

Dry Coil Data

MED
HIGH
LOW
MED
HIGH
LOW
MED
HIGH
LOW
MED

Volts
CFM
WATTS
CFM
230
WATTS
CFM
230
WATTS
CFM
230
WATTS
CFM
230
WATTS
CFM
230
WATTS
CFM
230
WATTS
CFM
230
WATTS
CFM
230
WATTS
230

CFM
WATTS
CFM
230
WATTS
230

CFM
WATTS
CFM
LOW
230
WATTS
CFM
MED
230
WATTS
CFM
HIGH
230
WATTS
CFM
T1 LOW
230
WATTS
CFM
T2 - T3 MED 230
WATTS
CFM
T4 - T5 HIGH 230
WATTS
HIGH

230

E.S.P (In. of H2O)


0.1
630

0.2
580

0.3
545

0.4
500

0.5
470

0.6
-

0.7
-

0.8
-

155
865
230
1,190
370
1,150
340

150
815
220
1,130
360
1,080
330

145
770
215
1,060
345
1,025
315

140
720
210
990
335
975
305

135
670
200
935
320
925
295

610
195
845
310
845
280

555
185
770
290
-

680
275
-

1,335
425
1,435
485

1,275
415
1,355
465

1,205
400
1,290
455

1,135
385
1,210
435

1,075
370
1,130
415

985
350
1,040
400

910
330
960
385

845
310
885
370

1,180
335
1,350
435
1,450

1,125
325
1,280
420
1,370

1,075
315
1,205
405
1,290

1,020
305
1,130
385
1,205

955
295
1,050
375
1,130

875
275
985
350
1,040

655
240
910
330
960

845
310
885

495
1,425
450
1,620

480
1,410
445
1,595

465
1,355
430
1,545

440
1,310
420
1,485

425
1,245
405
1,425

400
1,170
390
1,345

385
1,080
370
1,250

370
1,160

550
1,945
765
1,425
450
1,720
560
2,110
785

540
1,935
755
1,410
445
1,660
555
2,060
780

525
1,875
735
1,355
430
1,585
540
1,980
765

510
1,800
715
1,310
420
1,520
530
1,895
745

495
1,730
695
1,245
405
1,460
520
1,795
720

475
1,635
670
1,170
390
1,365
490
1,705
705

450
1,535
640
1,080
370
1,270
470
1,590
665

425
1,440
615
1,500
625

1,860
410
1,990
510

1,800
425
1,945
520

1,745
440
1,885
530

1,695
455
1,835
545

1,650
470
1,785
555

1,600
480
1,740
570

1,555
495
1,695
585

1,500
500
1,645
590

2,100
595

2,045
610

1,985
620

1,945
630

1,895
645

1,850
660

1,800
670

1,750
680

NOTES:
1.
2.
3.
4.

Data shown is Dry Coil. Wet Coil Pressure Drop is approximate.


0.1" H2O, for 2 row indoor coil; 0.2 H2O, for 3 row indoor coil; and 0.3 H2O, for 4 row indoor coil.
Data shown does not include filter pressure drop, approx. 0.08 H2O.
ALL MODELS SHOULD RUN NO LESS THAN 350 CFM / TON, USE HIGHER SPEED TAP OR NEXT SIZE LARGER BLOWER
ASM., SEE REPAIR PARTS LIST.
5. Reduce airflow by 2% for 208V operation.

18

GPH13[24-60]M21*

BLOWER PERFORMANCE DATA


Dry Coil Data

GPH1330M21*

GPH1324M21A*

Model

Speed
Low
Med

GPH1336M21*

230
230

Low

230

Med

230

High

M/L
M/H

230
230
230
230

E.S.P (In. of H2O)

CFM

0.1
685

0.2
635

0.3
-

0.4
-

0.5
-

0.6
-

0.7
-

0.8
-

WATTS

155

150

CFM

965

920

870

810

745

WATTS

240

235

230

225

215

CFM

1,320

1,290

1,240

1,180

1,115

1,040

950

820

WATTS

390

380

370

360

350

340

325

305

CFM

1185

1155

1077

1015

970

881

709

601

WATTS

333

323

314

306

296

283

263

251

CFM

1335

1291

1224

1158

1092

1012

908

778

WATTS

388

378

367

358

347

334

314

299

CFM

1535

1478

1408

1331

1250

1177

1074

962

WATTS

478
1,055

474
1,015

463
975

449
895

435
840

422
770

409
-

393
-

CFM
WATTS

315

310

300

285

270

255

CFM

1,285

1,240

1,190

1,120

1,040

950

850

WATTS

385

375

365

350

335

315

295

CFM

1,470

1,425

1,345

1,285

1,195

1,085

980

865

WATTS

455

440

425

410

385

370

350

325

CFM

1,565

1,510

1,415

1,340

1,260

1,135

1,035

885

WATTS

495

480

460

445

425

405

385

355

CFM

1,140

1,395

1,360

1,310

1,265

1,235

1,190

1,130

WATTS

275

285

295

315

325

335

345

355

CFM
T2 / T3
230
(W2)
WATTS

1,795

1,765

1,715

1,695

1,650

1,600

1,500

1,375

475

490

505

520

530

535

510

475

CFM
T4 / T5
230
(Y)
WATTS

1,860

1,820

1,785

1,745

1,700

1,625

1,515

1,395

HIGH
GPH1348M21*

230

High

LOW

GPH1360M21A*

Volts

230

T1 (G) 230

T1 (G) 230

CFM

515

530

545

565

570

550

535

485

1,755

1,720

1,685

1,645

1,615

1,570

1,530

1,465

420

435

455

460

475

490

500

500

CFM
T2 / T3
230
W2
WATTS

1,850

1,820

1,775

1,735

1,705

1,675

1,610

1,495

480

500

515

525

535

555

545

520

CFM
T4 / T5
230
Y
WATTS

2,180

2,125

2,050

1,975

1,875

1,800

1,655

1,530

770

755

725

700

675

640

575

540

WATTS

NOTES:
1.
2.
3.
4.

Data shown is Dry Coil. Wet Coil Pressure Drop is approximate.


0.1" H2O, for 2 row indoor coil; 0.2 H2O, for 3 row indoor coil; and 0.3 H2O, for 4 row indoor coil.
Data shown does not include filter pressure drop, approx. 0.08 H2O.
ALL MODELS SHOULD RUN NO LESS THAN 350 CFM / TON, USE HIGHER SPEED TAP OR NEXT SIZE LARGER BLOWER
ASM., SEE REPAIR PARTS LIST.
5. Reduce airflow by 2% for 208V operation.

19

20

10

20

30

40

50

60

70

30

80

90

100

40

50

60

700

600 CFM

90

100

2000
2200
2400 CFM

1800

1600

1400

OUTPUT BTU/HR x 1000

80

1200

1100

1000

900

70

800

FORMULAS

110

120

130

140

BTU OUTPUT = CFM x 1.08 x RISE


BTU OUTPUT
RISE =
CFM
1.08

BTU OUTPUT vs TEMPERATURE RISE CHART

150

BLOWER PERFORMANCE DATA

TEMPERATURE RISE

24.7
0.60
16
1.88
6.7
163
68

22.8
0.58
16
1.84
6.5
158
66

25.7
0.77
19
1.91
6.8
166
70

24.9
0.73
20
1.90
6.7
164
69

MBh
23.8
S/T
0.72
Delta T 18
KW
1.84
AMPS 6.5
HI PR 151
LO PR
64

MBh
22.0
S/T
0.69
Delta T 19
KW
1.80
AMPS 6.3
HI PR 147
LO PR
62

MBh
24.9
S/T
0.86
Delta T 21
KW
1.87
AMPS 6.6
HI PR 154
LO PR
66

MBh
24.2
S/T
0.82
Delta T 21
KW
1.86
AMPS 6.6
HI PR 153
LO PR
65

850

744

956

850

956

63
25.4
0.63
15
1.90
6.7
164
69

59
MBh
24.5
S/T
0.75
Delta T 18
KW
1.86
AMPS 6.6
HI PR 153
LO PR
65

Airflow

65

27.0
0.55
16
1.96
7.0
174
76

27.8
0.58
15
1.97
7.0
175
76

24.9
0.40
12
1.89
6.7
167
73

27.0
0.42
12
1.94
6.9
172
75

67
27.8
0.44
12
1.95
7.0
174
76

28.9
0.36
11
2.02
7.2
181
80

29.8
0.37
11
2.03
7.3
183
81

71
-

23.6
0.85
22
2.00
7.1
172
69

24.3
0.89
21
2.01
7.2
173
69

21.4
0.72
19
1.94
6.9
165
66

23.2
0.74
19
1.98
7.1
170
68

59
23.9
0.78
18
2.00
7.1
171
69

24.3
0.76
20
2.04
7.3
185
73

25.1
0.79
19
2.05
7.4
186
74

22.2
0.60
16
1.98
7.0
177
70

24.1
0.62
16
2.02
7.2
183
72

63
24.8
0.65
16
2.04
7.3
185
73

75

26.3
0.57
16
2.10
7.5
195
80

27.1
0.60
16
2.12
7.6
197
81

24.3
0.42
13
2.04
7.3
187
77

26.4
0.43
12
2.09
7.5
193
79

67
27.2
0.45
12
2.10
7.5
195
80

28.3
0.37
11
2.17
7.8
203
85

29.1
0.39
11
2.19
7.9
205
86

71
-

23.1
0.87
22
2.12
7.8
195
71

23.8
0.91
21
2.14
7.8
197
72

20.9
0.74
19
2.05
7.5
187
69

22.7
0.76
19
2.10
7.7
193
71

59
23.4
0.80
18
2.12
7.8
195
71

25.7
0.59
16
2.23
8.2
222
83

26.5
0.62
16
2.25
8.3
224
84

23.8
0.43
13
2.16
7.9
213
80

25.8
0.44
12
2.21
8.1
219
82

27.6
0.38
11
2.30
8.5
231
88

28.4
0.40
11
2.32
8.6
233
89

21.9 23.7 25.5


0.75 0.57 0.36
20
17
11
2.11 2.18 2.25
7.7
8.0
8.3
204
215
224
74
80
86
(TVA) conditions

23.7
0.78
20
2.16
7.9
210
76

24.5
0.81
19
2.18
8.0
212
77

21.7
0.61
16
2.10
7.7
202
73

23.5
0.64
16
2.15
7.9
208
75

20.8
0.86
22
2.17
8.1
215
73

22.5
0.90
22
2.23
8.3
222
75

23.2
0.94
21
2.24
8.4
224
76

20.4
0.76
19
2.16
8.0
213
72

22.1
0.79
19
2.21
8.2
220
74

23.9
0.84
19
2.29
8.6
241
81
23.2
0.80
20
2.27
8.5
239
80
21.4
0.77
20
2.22
8.3
232
77

21.2
0.63
17
2.20
8.2
230
77

22.9
0.66
16
2.26
8.4
237
79

23.1
0.58
17
2.29
8.5
245
85

25.1
0.61
16
2.35
8.8
252
87

25.8
0.64
16
2.37
8.9
255
88

23.2
0.44
13
2.27
8.5
242
84

25.1
0.46
12
2.33
8.7
250
86

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
24.2 26.5
22.8
23.6
25.9
0.67 0.46
0.83
0.69
0.48
16
12
18
16
12
2.16 2.23
2.23
2.27
2.35
7.9
8.2
8.3
8.5
8.8
210
222
222
239
252
76
83
75
80
87

24.8
0.38
12
2.36
8.9
255
90

26.9
0.39
11
2.42
9.1
263
93

27.7
0.41
11
2.44
9.2
266
94

71
-

EXPANDED PERFORMANCE DATA

MBh
22.3 23.0 24.9 26.7 21.8 22.5 24.3 26.1 21.3
S/T
0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84
Delta T 22
20
16
11
22
20
17
11
22
744
KW
1.82 1.85 1.91 1.97 1.95 1.99 2.05 2.12 2.07
AMPS 6.4
6.6
6.8
7.0
6.9
7.1
7.3
7.6
7.5
HI PR 148
160
168
176
166
179
189
197
189
LO PR
63
67
73
78
67
71
77
82
69
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA
High and low pressures are measured at the liquid and suction access fittings.

75

70

IDB*

MODEL: GPH1324H21*

19.7
0.90
22
2.26
8.6
242
76

21.4
0.93
21
2.32
8.8
250
79

22.0
0.97
21
2.34
8.9
252
79

19.4
0.79
19
2.24
8.5
240
75

21.0
0.82
19
2.30
8.8
247
78

59
21.6
0.86
18
2.32
8.8
250
79

20.3
0.80
20
2.31
8.8
261
81

22.0
0.83
20
2.37
9.1
269
84

22.7
0.87
19
2.39
9.1
272
84

20.1
0.66
16
2.29
8.7
258
80

21.8
0.68
16
2.35
9.0
266
83

63
22.4
0.72
15
2.37
9.1
269
84

22.0
0.61
16
2.38
9.1
275
89

23.8
0.63
16
2.44
9.4
284
91

24.5
0.66
16
2.46
9.5
287
92

22.0
0.46
12
2.36
9.0
273
88

23.9
0.47
12
2.42
9.3
281
90

67
24.6
0.50
12
2.44
9.4
284
91

105

23.6
0.39
11
2.46
9.4
287
94

25.6
0.40
11
2.52
9.7
296
97

26.3
0.42
11
2.55
9.8
299
98

71
-

18.3
0.90
20
2.34
9.1
268
79

19.8
0.94
20
2.40
9.4
276
81

20.4
0.98
19
2.42
9.5
279
82

18.0
0.80
18
2.32
9.0
265
78

19.5
0.82
17
2.38
9.3
273
80

59
20.1
0.86
17
2.40
9.4
276
81

18.8
0.81
19
2.39
9.3
288
84

20.4
0.84
18
2.45
9.6
297
87

21.0
0.88
18
2.47
9.7
300
87

18.6
0.66
15
2.37
9.2
285
83

20.2
0.69
15
2.43
9.5
294
86

63
20.8
0.72
14
2.45
9.6
297
86

20.4
0.61
15
2.47
9.6
304
92

22.1
0.63
15
2.53
9.9
314
94

22.7
0.67
15
2.55
10.0
317
95

20.4
0.46
12
2.44
9.6
301
91

22.1
0.48
11
2.51
9.8
311
93

67
22.8
0.50
11
2.53
9.9
314
94

115

21.9
0.39
11
2.55
10.0
317
98

23.7
0.41
10
2.61
10.3
327
101

24.4
0.43
10
2.63
10.4
331
102

71
-

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1324H21*

21

22

25.2
0.84
23
1.91
6.8
166
70

23.2
0.81
23
1.87
6.6
161
68

26.3
0.95
24
1.94
6.9
169
71

25.5
0.91
25
1.93
6.9
168
71

MBh
24.6
S/T
0.90
Delta T 24
KW
1.87
AMPS 6.6
HI PR 154
LO PR
66

MBh
22.7
S/T
0.86
Delta T 24
KW
1.83
AMPS 6.5
HI PR 150
LO PR
64

MBh
25.8
S/T
0.98
Delta T 24
KW
1.90
AMPS 6.8
HI PR 157
LO PR
67

MBh
25.0
S/T
0.94
Delta T 25
KW
1.89
AMPS 6.7
HI PR 156
LO PR
66

850

744

956

850

956

63
25.9
0.88
22
1.93
6.9
168
71

59
MBh
25.4
S/T
0.94
Delta T 23
KW
1.89
AMPS 6.7
HI PR 156
LO PR
66

Airflow

65

26.7
0.82
24
1.99
7.1
177
77

27.5
0.86
23
2.00
7.2
179
78

24.8
0.66
20
1.92
6.8
170
74

26.9
0.68
20
1.97
7.0
175
76

67
27.7
0.72
19
1.99
7.1
177
77

28.5
0.66
20
2.05
7.4
185
82

29.4
0.70
20
2.06
7.4
187
83

26.5
0.49
16
1.98
7.1
177
79

28.7
0.51
16
2.03
7.3
183
81

71
29.6
0.54
15
2.05
7.4
185
82

24.5
0.97
26
2.03
7.3
175
70

25.2
1.00
24
2.04
7.3
177
71

22.2
0.90
25
1.97
7.0
168
67

24.0
0.93
24
2.01
7.2
173
69

59
24.8
1.00
24
2.03
7.3
175
70

24.9
0.94
25
2.07
7.4
188
75

25.7
0.98
24
2.09
7.5
190
75

22.7
0.84
24
2.01
7.2
181
72

24.6
0.87
23
2.06
7.4
186
74

63
25.3
0.91
22
2.07
7.4
188
75

75

26.1
0.85
24
2.14
7.7
199
81

26.9
0.89
23
2.15
7.8
201
82

24.2
0.68
20
2.07
7.4
191
78

26.3
0.71
20
2.12
7.6
197
81

67
27.0
0.74
19
2.14
7.7
199
81

27.9
0.69
21
2.20
8.0
207
87

28.7
0.72
20
2.22
8.1
209
88

25.9
0.51
16
2.13
7.7
199
83

28.1
0.53
16
2.19
7.9
205
86

71
28.9
0.56
15
2.20
8.0
207
87

23.9
1.00
26
2.15
7.9
199
73

24.6
1.00
24
2.17
8.0
201
74

21.7
0.92
25
2.08
7.6
191
70

23.5
0.95
24
2.14
7.8
197
72

59
24.2
1.00
23
2.15
7.9
199
73

25.5
0.87
24
2.27
8.4
226
85

26.3
0.91
23
2.29
8.4
228
85

23.7
0.70
20
2.20
8.1
217
81

25.6
0.73
20
2.25
8.3
224
84

27.2
0.71
21
2.34
8.7
236
90

28.0
0.74
20
2.36
8.8
238
91

25.3
0.52
16
2.27
8.4
227
87

27.4
0.54
16
2.32
8.6
234
89

22.5 23.5 25.1


0.93 0.84 0.68
26
24
21
2.15 2.21 2.28
7.9
8.1
8.4
208
219
229
75
82
87
Rating Conditions

24.3
0.96
25
2.20
8.1
214
78

25.1
1.00
24
2.22
8.2
216
78

22.1
0.86
24
2.13
7.8
206
74

24.0
0.89
23
2.18
8.0
212
77

21.5
0.99
26
2.21
8.2
220
74

23.3
1.00
25
2.26
8.5
227
77

24.0
1.00
23
2.28
8.5
229
77

21.1
0.95
25
2.19
8.1
218
73

22.9
0.98
24
2.24
8.4
224
76

21.9
0.96
26
2.25
8.4
237
79

23.8
0.99
26
2.31
8.7
244
81

24.5
1.00
24
2.33
8.7
246
82

21.6
0.89
24
2.24
8.3
234
78

23.4
0.92
23
2.29
8.6
241
81

23.0
0.86
25
2.33
8.7
250
86

24.9
0.90
24
2.39
9.0
258
89

25.6
0.94
23
2.40
9.0
260
90

23.1
0.72
21
2.31
8.6
247
85

25.0
0.75
20
2.37
8.9
255
88

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
24.7 26.4 28.2 23.6
24.1
25.8
0.94 0.76 0.57 1.00
0.97
0.79
22
19
15
23
22
19
2.20 2.27 2.34 2.26
2.31
2.39
8.1
8.4
8.7
8.5
8.7
9.0
214
226
236
227
244
258
78
85
90
77
81
89

24.5
0.70
21
2.40
9.0
261
92

26.5
0.73
21
2.46
9.3
269
95

27.3
0.76
20
2.48
9.4
271
96

24.7
0.54
16
2.38
9.0
258
91

26.7
0.56
16
2.44
9.2
266
94

71
27.5
0.59
16
2.46
9.3
269
95

EXPANDED PERFORMANCE DATA

MBh
23.1 23.6 24.7 26.3 22.6 23.0 24.1 25.7 22.0
S/T
0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96
Delta T 26
25
24
21
26
26
24
21
26
744
KW
1.84 1.88 1.94 2.00 1.98 2.02 2.08 2.15 2.10
AMPS 6.5
6.7
6.9
7.2
7.1
7.2
7.5
7.8
7.7
HI PR 151
163
172
179
170
183
193
201
193
LO PR
64
68
75
80
68
72
79
84
71
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI
High and low pressures are measured at the liquid and suction access fittings.

85

80

IDB*

MODEL: GPH1324H21*

20.4
1.00
25
2.30
8.7
247
78

22.1
1.00
24
2.36
9.0
255
80

22.8
1.00
22
2.37
9.1
258
81

20.1
0.98
24
2.28
8.7
245
77

21.8
1.00
24
2.34
8.9
252
79

59
22.4
1.00
22
2.36
9.0
255
80

20.8
0.99
26
2.35
9.0
266
83

22.6
1.00
24
2.41
9.2
274
85

23.2
1.00
22
2.43
9.3
277
86

20.5
0.92
23
2.33
8.9
264
82

22.2
0.96
23
2.39
9.1
272
84

63
22.9
1.00
22
2.41
9.2
274
85

21.8
0.90
24
2.42
9.3
281
90

23.6
0.93
24
2.48
9.5
290
93

24.3
0.98
23
2.51
9.6
293
94

21.9
0.75
20
2.40
9.2
278
89

23.8
0.78
20
2.46
9.5
287
92

67
24.5
0.82
19
2.48
9.5
290
93

105

23.3
0.73
21
2.50
9.6
293
96

25.2
0.76
21
2.57
9.9
302
99

26.0
0.79
20
2.59
10.0
305
100

23.4
0.56
16
2.48
9.5
290
95

25.4
0.58
16
2.55
9.8
299
98

71
26.2
0.61
15
2.57
9.9
302
99

18.9
1.00
23
2.38
9.3
273
80

20.5
1.00
22
2.44
9.5
282
83

21.1
1.00
20
2.46
9.6
285
84

18.6
0.99
23
2.36
9.2
271
80

20.2
1.00
22
2.42
9.5
279
82

59
20.8
1.00
20
2.44
9.5
282
83

19.3
1.00
24
2.43
9.5
294
86

20.9
1.00
23
2.49
9.8
303
88

21.5
1.00
21
2.51
9.9
306
89

19.0
0.93
22
2.41
9.4
291
85

20.6
0.96
21
2.47
9.7
300
87

63
21.2
1.00
20
2.49
9.8
303
88

20.2
0.91
23
2.51
9.8
311
93

21.9
0.94
22
2.57
10.1
320
96

22.5
0.98
21
2.59
10.2
323
97

20.3
0.76
19
2.49
9.7
307
93

22.0
0.78
19
2.55
10.0
317
95

67
22.7
0.82
18
2.57
10.1
320
96

115

21.6
0.73
20
2.59
10.2
324
100

23.4
0.76
19
2.66
10.5
334
103

24.1
0.80
18
2.68
10.6
337
104

21.7
0.57
15
2.57
10.1
321
99

23.5
0.59
15
2.63
10.4
331
102

71
24.2
0.62
14
2.66
10.5
334
103

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1324H21*

28.2
0.60
15
2.08
7.6
166
68

26.0
0.58
15
2.04
7.4
161
66

29.3
0.77
17
2.12
7.8
169
69

28.5
0.73
18
2.10
7.7
168
68

MBh
27.2
S/T
0.72
Delta T 17
KW
2.04
AMPS 7.5
HI PR 154
LO PR
64

MBh
25.1
S/T
0.69
Delta T 17
KW
1.99
AMPS 7.3
HI PR 150
LO PR
62

MBh
28.5
S/T
0.86
Delta T 19
KW
2.07
AMPS 7.6
HI PR 157
LO PR
65

MBh
27.7
S/T
0.82
Delta T 20
KW
2.06
AMPS 7.5
HI PR 156
LO PR
64

1050

919

1181

1050

1181

63
29.0
0.63
14
2.10
7.7
168
68

59
MBh
28.0
S/T
0.75
Delta T 16
KW
2.06
AMPS 7.5
HI PR 156
LO PR
64

Airflow

65

30.8
0.55
15
2.17
8.0
177
75

31.8
0.58
14
2.18
8.0
179
75

28.5
0.40
11
2.10
7.7
170
72

30.9
0.42
11
2.15
7.9
175
74

67
31.8
0.44
11
2.17
8.0
177
75

33.1
0.36
10
2.24
8.3
185
80

34.1
0.37
10
2.25
8.4
187
80

71
-

27.0
0.85
20
2.22
8.2
175
68

27.8
0.89
19
2.23
8.2
177
69

24.5
0.72
18
2.14
7.9
168
65

26.6
0.74
17
2.20
8.1
173
67

59
27.4
0.78
17
2.22
8.2
175
68

27.8
0.76
18
2.26
8.4
188
72

28.7
0.79
18
2.28
8.4
190
73

25.4
0.60
15
2.19
8.0
181
69

27.5
0.62
15
2.24
8.3
186
72

63
28.4
0.65
14
2.26
8.4
188
72

75

30.1
0.57
15
2.34
8.6
199
79

31.0
0.60
15
2.35
8.7
201
80

27.9
0.42
12
2.26
8.3
191
76

30.2
0.43
11
2.32
8.6
197
78

67
31.1
0.45
11
2.33
8.6
199
79

32.3
0.37
10
2.41
9.0
207
84

33.3
0.39
10
2.43
9.1
209
85

71
-

26.4
0.87
20
2.35
8.9
199
71

27.2
0.91
19
2.37
9.0
201
71

23.9
0.74
18
2.28
8.5
191
68

25.9
0.76
17
2.33
8.8
197
70

59
26.7
0.80
17
2.35
8.9
199
71

29.4
0.59
15
2.48
9.4
226
82

30.3
0.62
15
2.50
9.5
228
83

27.2
0.43
12
2.40
9.1
217
79

29.5
0.44
11
2.46
9.3
224
81

31.6
0.38
10
2.57
9.8
236
87

32.5
0.40
10
2.59
9.9
238
88

25.1 27.1 29.1


0.75 0.57 0.36
19
15
11
2.35 2.42 2.50
8.8
9.1
9.5
208
219
229
73
80
85
(TVA) conditions

27.2
0.78
18
2.41
9.1
214
75

28.0
0.81
18
2.43
9.2
216
76

24.8
0.61
15
2.33
8.8
206
72

26.9
0.64
15
2.39
9.0
212
74

23.8
0.86
21
2.42
9.2
220
72

25.7
0.90
20
2.48
9.5
227
74

26.5
0.94
19
2.50
9.6
229
75

23.4
0.76
18
2.40
9.1
217
71

25.3
0.79
17
2.46
9.4
224
73

27.3
0.84
18
2.55
9.8
246
80
26.5
0.80
19
2.53
9.7
244
79
24.5
0.77
19
2.47
9.5
236
77

24.2
0.63
15
2.45
9.4
234
76

26.2
0.66
15
2.51
9.6
241
78

26.5
0.58
15
2.55
9.8
250
84

28.7
0.61
15
2.61
10.1
257
86

29.5
0.64
15
2.64
10.2
260
87

26.5
0.44
12
2.53
9.7
247
83

28.7
0.46
11
2.59
10.0
255
85

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
27.7 30.3
26.1
27.0
29.6
0.67 0.46
0.83
0.69
0.48
14
11
17
15
11
2.41 2.48
2.48
2.53
2.61
9.1
9.4
9.5
9.7
10.1
214
226
226
244
257
75
82
74
79
86

28.4
0.38
11
2.63
10.2
260
89

30.8
0.39
11
2.70
10.5
268
92

31.7
0.41
10
2.72
10.6
271
93

71
-

EXPANDED PERFORMANCE DATA

MBh
25.5 26.3 28.5 30.5 24.9 25.7 27.8 29.8 24.4
S/T
0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84
Delta T 20
19
15
10
20
19
15
11
20
919
KW
2.01 2.05 2.12 2.18 2.16 2.21 2.28 2.35 2.30
AMPS 7.3
7.5
7.8
8.0
7.9
8.1
8.4
8.7
8.6
HI PR 151
163
172
179
170
183
193
201
193
LO PR
62
66
72
77
66
70
77
82
68
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA
High and low pressures are measured at the liquid and suction access fittings.

75

70

IDB*

MODEL: GPH1330H21*

22.6
0.90
20
2.52
9.8
247
75

24.5
0.93
20
2.58
10.1
255
78

25.2
0.97
19
2.60
10.2
257
78

22.2
0.79
18
2.50
9.7
245
75

24.0
0.82
17
2.56
10.0
252
77

59
24.8
0.86
17
2.58
10.1
255
78

23.2
0.80
19
2.57
10.1
266
80

25.2
0.83
18
2.64
10.4
274
83

25.9
0.87
18
2.66
10.5
277
84

23.0
0.66
15
2.55
10.0
263
79

24.9
0.68
15
2.62
10.3
271
82

63
25.7
0.72
14
2.64
10.4
274
83

25.2
0.61
15
2.66
10.4
281
88

27.3
0.63
15
2.73
10.7
290
90

28.1
0.66
14
2.75
10.8
292
91

25.2
0.46
12
2.63
10.3
278
87

27.3
0.47
11
2.70
10.6
287
89

67
28.1
0.50
11
2.72
10.7
290
90

105

27.0
0.39
11
2.75
10.8
293
93

29.2
0.40
10
2.82
11.2
302
96

30.1
0.42
10
2.84
11.3
305
97

71
-

20.9
0.90
19
2.60
10.4
273
78

22.7
0.94
19
2.67
10.7
282
80

23.3
0.98
18
2.69
10.8
284
81

20.6
0.80
16
2.58
10.3
270
77

22.3
0.82
16
2.65
10.6
279
80

59
22.9
0.86
15
2.67
10.7
281
80

21.5
0.81
17
2.66
10.7
294
83

23.3
0.84
17
2.73
11.0
303
86

24.0
0.88
16
2.75
11.1
306
86

21.3
0.66
14
2.64
10.6
291
82

23.1
0.69
14
2.71
10.9
300
85

63
23.8
0.72
13
2.73
11.0
303
86

23.3
0.61
14
2.75
11.1
310
91

25.2
0.63
14
2.82
11.4
320
93

26.0
0.67
13
2.84
11.5
323
94

23.3
0.46
11
2.73
11.0
307
90

25.3
0.48
11
2.80
11.3
317
92

67
26.1
0.50
10
2.82
11.4
320
93

115

25.0
0.39
10
2.84
11.5
324
96

27.1
0.41
10
2.92
11.8
334
99

27.9
0.43
9
2.94
12.0
337
100

71
-

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1330H21*

23

24

28.8
0.84
21
2.12
7.8
169
69

26.6
0.81
22
2.07
7.6
164
67

30.1
0.95
22
2.15
7.9
173
70

29.2
0.91
23
2.14
7.9
171
70

MBh
28.2
S/T
0.90
Delta T 22
KW
2.07
AMPS 7.6
HI PR 157
LO PR
65

MBh
26.0
S/T
0.86
Delta T 22
KW
2.03
AMPS 7.4
HI PR 153
LO PR
63

MBh
29.5
S/T
0.98
Delta T 23
KW
2.11
AMPS 7.7
HI PR 161
LO PR
66

MBh
28.7
S/T
0.94
Delta T 24
KW
2.09
AMPS 7.7
HI PR 159
LO PR
66

1050

919

1181

1050

1181

63
29.6
0.88
20
2.14
7.9
171
70

59
MBh
29.0
S/T
0.94
Delta T 21
KW
2.09
AMPS 7.7
HI PR 159
LO PR
66

Airflow

65

30.6
0.82
22
2.20
8.1
181
76

31.5
0.86
21
2.22
8.2
182
77

28.4
0.66
19
2.13
7.8
174
73

30.7
0.68
18
2.19
8.0
179
75

67
31.7
0.72
18
2.20
8.1
181
76

32.6
0.66
19
2.27
8.4
188
81

33.6
0.70
18
2.29
8.5
190
82

30.3
0.49
15
2.20
8.1
181
78

32.9
0.51
15
2.25
8.4
187
80

71
33.9
0.54
14
2.27
8.4
188
81

28.0
0.97
24
2.25
8.3
178
69

28.8
1.00
22
2.27
8.4
180
70

25.4
0.90
23
2.18
8.0
171
67

27.5
0.93
22
2.23
8.2
177
69

59
28.3
1.00
22
2.25
8.3
178
69

28.5
0.94
23
2.30
8.5
192
74

29.4
0.98
23
2.32
8.6
194
74

25.9
0.84
22
2.23
8.2
184
71

28.1
0.87
21
2.28
8.4
190
73

63
29.0
0.91
21
2.30
8.5
192
74

75

29.9
0.85
22
2.37
8.8
203
80

30.8
0.89
21
2.39
8.9
205
81

27.7
0.68
19
2.30
8.5
195
77

30.0
0.71
19
2.35
8.7
201
80

67
30.9
0.74
18
2.37
8.8
203
80

31.9
0.69
19
2.45
9.1
211
86

32.8
0.72
18
2.47
9.2
214
87

29.6
0.51
15
2.37
8.8
203
82

32.1
0.53
15
2.43
9.1
209
85

71
33.1
0.56
14
2.45
9.1
211
86

27.3
1.00
24
2.39
9.0
203
72

28.1
1.00
22
2.41
9.1
205
73

24.8
0.92
23
2.32
8.7
195
69

26.9
0.95
22
2.37
9.0
201
71

59
27.7
1.00
22
2.39
9.0
203
72

29.2
0.87
22
2.52
9.6
231
84

30.0
0.91
21
2.55
9.7
233
84

27.1
0.70
19
2.44
9.2
221
80

29.3
0.73
19
2.50
9.5
228
83

31.1
0.71
19
2.61
10.0
240
89

32.1
0.74
18
2.63
10.1
243
90

28.9
0.52
15
2.52
9.6
231
86

31.3
0.54
15
2.59
9.9
238
88

25.7 26.9 28.7


0.93 0.84 0.68
24
23
20
2.39 2.46 2.54
9.0
9.3
9.7
212
224
233
74
81
86
Rating Conditions

27.9
0.96
23
2.45
9.3
218
77

28.7
1.00
22
2.47
9.4
221
77

25.3
0.86
22
2.37
8.9
210
74

27.4
0.89
21
2.43
9.2
216
76

24.6
0.99
24
2.46
9.4
224
73

26.7
1.00
23
2.52
9.7
231
76

27.5
1.00
21
2.54
9.8
233
76

24.2
0.95
23
2.44
9.3
222
73

26.2
0.98
23
2.50
9.6
229
75

25.1
0.96
24
2.51
9.6
241
78

27.2
0.99
24
2.57
9.9
249
80

28.0
1.00
22
2.59
10.0
251
81

24.7
0.89
22
2.49
9.6
239
77

26.8
0.92
22
2.55
9.8
246
80

26.3
0.86
23
2.59
10.0
255
85

28.5
0.90
22
2.66
10.3
263
88

29.3
0.94
21
2.68
10.4
265
89

26.4
0.72
19
2.57
9.9
252
84

28.6
0.75
19
2.64
10.2
260
87

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
28.3 30.2 32.3 27.0
27.6
29.5
0.94 0.76 0.57 1.00
0.97
0.79
21
18
14
21
21
18
2.45 2.52 2.61 2.52
2.57
2.66
9.3
9.6
10.0
9.7
9.9
10.3
218
231
240
231
249
263
77
84
89
76
80
88

28.0
0.70
20
2.68
10.4
266
91

30.4
0.73
19
2.75
10.7
274
94

31.3
0.76
19
2.77
10.8
277
95

28.2
0.54
15
2.66
10.3
263
90

30.6
0.56
15
2.72
10.6
271
93

71
31.5
0.59
14
2.75
10.7
274
94

EXPANDED PERFORMANCE DATA

MBh
26.4 27.0 28.2 30.1 25.8 26.3 27.6 29.4 25.2
S/T
0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96
Delta T 24
24
22
19
24
24
23
20
24
919
KW
2.04 2.08 2.15 2.22 2.20 2.24 2.32 2.39 2.33
AMPS 7.5
7.6
7.9
8.2
8.1
8.3
8.6
8.9
8.8
HI PR 154
166
175
183
173
186
197
205
197
LO PR
64
68
74
79
67
72
78
83
70
* Entering Indoor Dry Bulb Tem perature
NOTE: Shaded area is AHRI
High and low pressures are measured at the liquid and suction access fittings.

85

80

IDB*

MODEL: GPH1330H21*

23.4
1.00
23
2.56
10.0
252
77

25.3
1.00
22
2.62
10.3
260
79

26.1
1.00
20
2.65
10.4
263
80

23.0
0.98
23
2.54
9.9
250
76

24.9
1.00
22
2.60
10.2
257
79

59
25.6
1.00
20
2.62
10.3
260
79

23.8
0.99
24
2.62
10.3
271
82

25.8
1.00
23
2.68
10.6
280
84

26.6
1.00
21
2.71
10.7
283
85

23.5
0.92
22
2.59
10.2
269
81

25.4
0.96
21
2.66
10.5
277
84

63
26.2
1.00
20
2.68
10.6
280
84

25.0
0.90
22
2.70
10.6
287
89

27.0
0.93
22
2.77
10.9
295
92

27.8
0.98
21
2.79
11.0
298
93

25.1
0.75
19
2.68
10.5
284
88

27.2
0.78
19
2.75
10.8
293
91

67
28.0
0.82
18
2.77
10.9
295
92

105

26.6
0.73
19
2.79
11.0
299
95

28.8
0.76
19
2.86
11.4
308
98

29.7
0.79
18
2.89
11.5
311
99

26.8
0.56
15
2.77
10.9
296
94

29.0
0.58
15
2.84
11.3
305
97

71
29.9
0.61
14
2.86
11.4
308
98

21.7
1.00
22
2.65
10.6
279
80

23.5
1.00
21
2.72
11.0
287
82

24.2
1.00
19
2.74
11.1
290
83

21.3
0.99
21
2.63
10.5
276
79

23.1
1.00
20
2.69
10.8
284
81

59
23.7
1.00
18
2.72
11.0
287
82

22.1
1.00
22
2.71
10.9
300
85

23.9
1.00
21
2.78
11.2
309
87

24.6
1.00
19
2.80
11.3
312
88

21.7
0.93
20
2.68
10.8
297
84

23.6
0.96
20
2.75
11.1
306
86

63
24.3
1.00
19
2.78
11.2
309
87

23.1
0.91
21
2.80
11.3
317
92

25.0
0.94
21
2.87
11.6
326
95

25.8
0.98
20
2.89
11.7
330
96

23.2
0.76
18
2.77
11.2
313
91

25.2
0.78
17
2.85
11.5
323
94

67
25.9
0.82
17
2.87
11.6
326
95

115

24.7
0.73
18
2.89
11.7
330
98

26.7
0.76
18
2.97
12.1
340
101

27.5
0.80
17
2.99
12.2
344
102

24.8
0.57
14
2.87
11.6
327
97

26.9
0.59
14
2.94
12.0
337
100

71
27.7
0.62
13
2.97
12.1
340
101

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1330H21*

34.5
0.60
15
2.38
9.4
160
66

31.9
0.58
15
2.33
9.1
155
64

35.9
0.77
18
2.42
9.6
163
67

34.9
0.73
19
2.40
9.5
161
67

MBh
33.3
S/T
0.72
Delta T 18
KW
2.33
AMPS 9.2
HI PR 148
LO PR
62

MBh
30.7
S/T
0.69
Delta T 18
KW
2.28
AMPS 8.9
HI PR 144
LO PR
60

MBh
34.9
S/T
0.86
Delta T 20
KW
2.37
AMPS 9.4
HI PR 151
LO PR
63

MBh
33.9
S/T
0.82
Delta T 20
KW
2.35
AMPS 9.3
HI PR 150
LO PR
63

1250

1094

1406

1250

1406

63
35.5
0.63
15
2.40
9.5
161
67

59
MBh
34.3
S/T
0.75
Delta T 17
KW
2.35
AMPS 9.3
HI PR 150
LO PR
63

Airflow

65

37.7
0.55
15
2.48
9.8
170
73

38.9
0.58
15
2.50
9.9
172
74

34.9
0.40
12
2.40
9.5
164
70

37.8
0.42
12
2.46
9.7
169
72

67
38.9
0.44
11
2.48
9.8
170
73

40.5
0.36
11
2.56
10.2
178
78

41.7
0.37
10
2.59
10.3
179
78

71
-

33.1
0.85
21
2.54
10.1
168
66

34.1
0.89
20
2.56
10.1
170
67

30.0
0.72
18
2.46
9.7
161
64

32.5
0.74
18
2.52
10.0
166
66

59
33.5
0.78
17
2.54
10.0
168
66

34.1
0.76
19
2.60
10.3
181
71

35.1
0.79
18
2.62
10.4
183
71

31.1
0.60
16
2.51
9.9
174
68

33.7
0.62
15
2.57
10.2
179
70

63
34.7
0.65
15
2.59
10.3
181
71

75

36.9
0.57
16
2.68
10.7
191
77

38.0
0.60
15
2.70
10.8
193
78

34.1
0.42
12
2.59
10.3
183
74

36.9
0.43
12
2.66
10.6
189
76

67
38.0
0.45
11
2.68
10.7
191
77

39.6
0.37
11
2.77
11.1
199
82

40.7
0.39
10
2.79
11.2
201
83

71
-

32.3
0.87
21
2.70
11.0
191
69

33.3
0.91
20
2.73
11.1
193
70

29.3
0.74
18
2.61
10.5
184
66

31.7
0.76
18
2.68
10.9
189
68

59
32.7
0.80
17
2.70
11.0
191
69

36.0
0.59
16
2.86
11.6
217
80

37.1
0.62
15
2.88
11.7
219
81

33.3
0.43
12
2.76
11.2
209
77

36.1
0.44
12
2.83
11.5
215
79

38.6
0.38
11
2.95
12.1
227
85

39.8
0.40
10
2.98
12.2
229
86

30.7 33.2 35.6


0.75 0.57 0.36
19
16
11
2.69 2.78 2.88
10.9 11.3 11.7
200
211
220
71
78
83
(TVA) conditions

33.2
0.78
19
2.76
11.2
206
73

34.2
0.81
18
2.79
11.3
208
74

30.4
0.61
16
2.67
10.8
198
70

32.9
0.64
15
2.74
11.1
204
73

29.1
0.86
21
2.78
11.4
211
70

31.5
0.90
21
2.85
11.7
218
72

32.4
0.94
20
2.87
11.8
220
73

28.6
0.76
18
2.75
11.3
209
70

31.0
0.79
18
2.82
11.6
216
72

33.4
0.84
18
2.94
12.1
237
78
32.4
0.80
19
2.91
12.0
234
77
29.9
0.77
19
2.84
11.7
227
75

29.6
0.63
16
2.81
11.6
225
74

32.1
0.66
16
2.89
11.9
232
76

32.4
0.58
16
2.93
12.1
240
82

35.1
0.61
16
3.01
12.5
248
84

36.2
0.64
15
3.04
12.6
250
85

32.5
0.44
12
2.91
12.0
238
81

35.2
0.46
12
2.98
12.3
245
83

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
33.9 37.1
31.9
33.1
36.2
0.67 0.46
0.83
0.69
0.48
15
11
17
15
11
2.76 2.86
2.85
2.91
3.01
11.2 11.6
11.7
12.0
12.4
206
217
218
234
247
73
80
72
77
84

34.8
0.38
11
3.03
12.6
250
87

37.7
0.39
11
3.11
12.9
258
90

38.8
0.41
10
3.14
13.1
261
91

71
-

EXPANDED PERFORMANCE DATA

MBh
31.3 32.2 34.8 37.4 30.5 31.4 34.0 36.5 29.8
S/T
0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84
Delta T 21
19
16
11
21
19
16
11
21
1094
KW
2.30 2.35 2.42 2.50 2.48 2.53 2.61 2.70 2.64
AMPS 9.0
9.2
9.5
9.9
9.8
10.0 10.4 10.8 10.6
HI PR 145
156
165
172
163
176
185
193
185
LO PR
61
65
71
75
64
68
75
80
67
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA
High and low pressures are measured at the liquid and suction access fittings.

75

70

IDB*

MODEL: GPH1336H21*

27.6
0.90
21
2.89
12.2
238
74

29.9
0.93
20
2.97
12.5
245
76

30.8
0.97
20
3.00
12.6
247
77

27.2
0.79
18
2.87
12.0
235
73

29.4
0.82
18
2.95
12.4
243
75

59
30.3
0.86
17
2.97
12.5
245
76

28.4
0.80
19
2.96
12.5
256
78

30.8
0.83
19
3.04
12.8
264
81

31.7
0.87
18
3.06
13.0
266
82

28.2
0.66
16
2.93
12.3
253
78

30.5
0.68
15
3.01
12.7
261
80

63
31.4
0.72
15
3.04
12.8
264
81

30.8
0.61
16
3.06
12.9
270
86

33.3
0.63
15
3.14
13.3
278
88

34.4
0.66
15
3.17
13.4
281
89

30.8
0.46
12
3.03
12.8
267
85

33.4
0.47
12
3.11
13.2
276
87

67
34.4
0.50
11
3.14
13.3
278
88

105

33.0
0.39
11
3.17
13.4
282
91

35.8
0.40
11
3.25
13.8
290
94

36.9
0.42
10
3.28
13.9
293
95

71
-

25.6
0.90
19
3.00
12.9
263
76

27.7
0.94
19
3.08
13.3
271
79

28.6
0.98
18
3.10
13.4
273
79

25.2
0.80
17
2.97
12.8
260
75

27.3
0.82
17
3.05
13.2
268
78

59
28.1
0.86
16
3.08
13.3
271
79

26.3
0.81
18
3.07
13.2
283
81

28.5
0.84
18
3.15
13.6
291
84

29.4
0.88
17
3.17
13.8
294
84

26.1
0.66
15
3.04
13.1
280
80

28.3
0.69
14
3.12
13.5
288
83

63
29.1
0.72
14
3.15
13.6
291
84

28.5
0.61
15
3.17
13.7
298
88

30.9
0.63
14
3.25
14.1
308
91

31.8
0.67
14
3.28
14.2
311
92

28.6
0.46
11
3.14
13.6
295
88

31.0
0.48
11
3.23
14.0
305
90

67
31.9
0.50
10
3.25
14.1
308
91

115

30.6
0.39
10
3.28
14.2
311
94

33.2
0.41
10
3.37
14.7
321
97

34.2
0.43
10
3.40
14.8
324
98

71
-

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1336H21*

25

26

35.2
0.84
22
2.42
9.6
163
68

32.5
0.81
22
2.36
9.3
158
65

36.8
0.95
23
2.46
9.8
166
69

35.7
0.91
24
2.44
9.7
165
68

MBh
34.5
S/T
0.90
Delta T 23
KW
2.37
AMPS 9.4
HI PR 151
LO PR
63

MBh
31.8
S/T
0.86
Delta T 23
KW
2.31
AMPS 9.1
HI PR 147
LO PR
62

MBh
36.1
S/T
0.98
Delta T 23
KW
2.41
AMPS 9.5
HI PR 154
LO PR
65

MBh
35.1
S/T
0.94
Delta T 24
KW
2.39
AMPS 9.4
HI PR 153
LO PR
64

1250

1094

1406

1250

1406

63
36.3
0.88
21
2.44
9.7
165
68

59
MBh
35.5
S/T
0.94
Delta T 22
KW
2.39
AMPS 9.4
HI PR 153
LO PR
64

Airflow

65

37.4
0.82
23
2.52
10.0
174
74

38.6
0.86
22
2.54
10.1
175
75

34.7
0.66
19
2.44
9.6
167
71

37.6
0.68
19
2.50
9.9
172
74

67
38.8
0.72
18
2.52
10.0
174
74

39.9
0.66
19
2.61
10.4
181
79

41.1
0.70
19
2.63
10.5
183
80

37.1
0.49
15
2.52
10.0
174
76

40.2
0.51
15
2.59
10.3
179
78

71
41.4
0.54
15
2.61
10.4
181
79

34.3
0.97
25
2.58
10.2
172
68

35.3
1.00
23
2.60
10.3
173
68

31.1
0.90
23
2.50
9.9
165
65

33.7
0.93
23
2.56
10.1
170
67

59
34.7
1.00
23
2.58
10.2
172
68

34.9
0.94
24
2.64
10.5
185
72

36.0
0.98
23
2.66
10.6
186
73

31.7
0.84
22
2.55
10.1
177
69

34.4
0.87
22
2.62
10.4
183
71

63
35.4
0.91
21
2.64
10.5
185
72

75

36.6
0.85
23
2.73
10.9
195
79

37.7
0.89
22
2.75
11.0
197
79

33.9
0.68
19
2.64
10.5
187
76

36.8
0.71
19
2.70
10.8
193
78

67
37.9
0.74
18
2.73
10.9
195
79

39.0
0.69
20
2.82
11.3
203
84

40.2
0.72
19
2.84
11.4
205
85

36.3
0.51
16
2.72
10.9
195
80

39.3
0.53
15
2.79
11.2
201
83

71
40.5
0.56
15
2.82
11.3
203
84

33.4
1.00
25
2.75
11.2
195
70

34.4
1.00
23
2.77
11.3
197
71

30.3
0.92
23
2.66
10.7
187
68

32.9
0.95
23
2.73
11.1
193
70

59
33.8
1.00
22
2.75
11.2
195
70

35.7
0.87
23
2.90
11.8
222
82

36.8
0.91
22
2.93
12.0
224
83

33.1
0.70
20
2.81
11.4
213
78

35.9
0.73
19
2.88
11.7
220
81

38.1
0.71
20
3.00
12.3
231
87

39.2
0.74
19
3.03
12.4
234
88

35.4
0.52
16
2.90
11.8
222
84

38.4
0.54
15
2.98
12.2
229
86

31.5 32.9 35.1


0.93 0.84 0.68
25
23
20
2.74 2.83 2.93
11.1 11.5 12.0
204
215
224
73
79
84
Rating Conditions

34.1
0.96
24
2.81
11.4
210
75

35.1
1.00
23
2.83
11.6
212
76

31.0
0.86
22
2.72
11.0
202
72

33.6
0.89
22
2.79
11.3
208
74

30.1
0.99
25
2.82
11.6
216
72

32.6
1.00
24
2.90
12.0
222
74

33.6
1.00
22
2.92
12.1
224
75

29.6
0.95
24
2.80
11.5
213
71

32.1
0.98
23
2.87
11.9
220
73

30.7
0.96
25
2.89
11.9
232
76

33.3
0.99
24
2.96
12.3
239
79

34.2
1.00
22
2.99
12.4
242
79

30.2
0.89
23
2.86
11.8
230
76

32.8
0.92
22
2.94
12.2
237
78

32.1
0.86
23
2.98
12.3
245
83

34.8
0.90
23
3.06
12.7
253
86

35.9
0.94
22
3.09
12.8
255
87

32.3
0.72
20
2.96
12.2
243
82

35.0
0.75
19
3.04
12.6
250
85

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
34.6 37.0 39.5 33.0
33.7
36.1
0.94 0.76 0.57 1.00
0.97
0.79
21
18
15
22
21
19
2.81 2.90 3.00 2.90
2.96
3.06
11.4 11.8 12.3 12.0
12.3
12.7
210
222
231
222
239
253
75
82
87
74
79
86

34.3
0.70
20
3.09
12.8
255
89

37.2
0.73
20
3.17
13.2
263
91

38.3
0.76
19
3.19
13.3
266
92

34.5
0.54
16
3.06
12.7
253
88

37.4
0.56
15
3.14
13.1
261
91

71
38.5
0.59
15
3.17
13.2
263
91

EXPANDED PERFORMANCE DATA

MBh
32.4 33.0 34.6 36.9 31.6 32.2 33.8 36.0 30.9
S/T
0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96
Delta T 25
24
23
20
25
25
23
20
25
1094
KW
2.33 2.38 2.46 2.54 2.52 2.57 2.66 2.75 2.68
AMPS 9.2
9.4
9.7
10.1 10.0 10.2 10.6 11.0 10.8
HI PR 148
160
169
176
166
179
189
197
189
LO PR
62
66
72
77
66
70
76
81
68
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI
High and low pressures are measured at the liquid and suction access fittings.

85

80

IDB*

MODEL: GPH1336H21*

28.6
1.00
24
2.94
12.4
242
75

31.0
1.00
23
3.02
12.8
250
77

31.9
1.00
21
3.05
12.9
252
78

28.1
0.98
23
2.92
12.3
240
74

30.5
1.00
22
3.00
12.6
248
77

59
31.4
1.00
21
3.02
12.8
250
77

29.2
0.99
24
3.01
12.7
261
80

31.6
1.00
23
3.09
13.1
269
82

32.5
1.00
21
3.12
13.2
272
83

28.7
0.92
22
2.99
12.6
258
79

31.1
0.96
22
3.06
13.0
266
82

63
32.1
1.00
21
3.09
13.1
269
82

30.5
0.90
23
3.11
13.1
276
87

33.1
0.93
23
3.20
13.5
284
90

34.1
0.98
22
3.22
13.7
287
91

30.7
0.75
19
3.09
13.0
273
86

33.3
0.78
19
3.17
13.4
281
89

67
34.2
0.82
18
3.20
13.5
284
90

105

32.6
0.73
20
3.22
13.7
287
93

35.3
0.76
20
3.31
14.1
296
96

36.4
0.79
19
3.34
14.2
299
97

32.8
0.56
15
3.19
13.5
285
92

35.5
0.58
15
3.28
13.9
293
95

71
36.6
0.61
15
3.31
14.1
296
96

26.5
1.00
22
3.05
13.2
268
78

28.7
1.00
21
3.13
13.5
276
80

29.6
1.00
19
3.16
13.7
279
81

26.0
0.99
22
3.02
13.0
265
77

28.2
1.00
21
3.10
13.4
273
79

59
29.1
1.00
19
3.13
13.5
276
80

27.0
1.00
23
3.12
13.5
288
83

29.3
1.00
22
3.20
13.9
297
85

30.1
1.00
20
3.23
14.0
300
86

26.6
0.93
21
3.09
13.4
285
82

28.8
0.96
20
3.17
13.8
294
84

63
29.7
1.00
19
3.20
13.9
297
85

28.3
0.91
22
3.23
14.0
304
90

30.6
0.94
21
3.31
14.4
314
93

31.6
0.98
20
3.34
14.5
317
94

28.4
0.76
18
3.20
13.8
301
89

30.8
0.78
18
3.28
14.2
311
92

67
31.7
0.82
17
3.31
14.4
314
93

115

30.2
0.73
19
3.34
14.5
318
96

32.7
0.76
18
3.43
14.9
327
99

33.7
0.80
18
3.46
15.1
331
100

30.4
0.57
14
3.31
14.4
314
95

32.9
0.59
14
3.40
14.8
324
98

71
33.9
0.62
14
3.43
14.9
327
99

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1336H21*

40.4
0.60
15
2.47
9.4
153
67

37.3
0.58
16
2.41
9.1
149
65

42.1
0.77
18
2.52
9.6
156
68

40.8
0.73
19
2.50
9.5
155
68

MBh
39.0
S/T
0.72
Delta T 18
KW
2.42
AMPS 9.2
HI PR 142
LO PR
63

MBh
36.0
S/T
0.69
Delta T 18
KW
2.36
AMPS 8.9
HI PR 138
LO PR
61

MBh
40.9
S/T
0.86
Delta T 20
KW
2.46
AMPS 9.4
HI PR 145
LO PR
64

MBh
39.7
S/T
0.82
Delta T 21
KW
2.44
AMPS 9.3
HI PR 144
LO PR
64

1450

1269

1631

1450

1631

63
41.6
0.63
15
2.50
9.5
155
68

59
MBh
40.2
S/T
0.75
Delta T 17
KW
2.44
AMPS 9.3
HI PR 144
LO PR
64

Airflow

65

44.2
0.55
15
2.58
9.8
163
74

45.5
0.58
15
2.60
9.9
165
75

40.9
0.40
12
2.49
9.5
157
71

44.3
0.42
12
2.56
9.7
162
73

67
45.6
0.44
11
2.58
9.8
163
74

47.4
0.36
11
2.66
10.2
170
79

48.9
0.37
10
2.68
10.3
172
79

71
-

38.7
0.85
21
2.64
10.1
161
67

39.9
0.89
20
2.66
10.1
163
68

35.2
0.72
18
2.55
9.7
155
64

38.1
0.74
18
2.61
10.0
160
66

59
39.2
0.78
17
2.64
10.0
161
67

39.9
0.76
19
2.69
10.3
174
71

41.1
0.79
18
2.72
10.4
175
72

36.4
0.60
16
2.60
9.9
167
69

39.5
0.62
16
2.67
10.2
172
71

63
40.7
0.65
15
2.69
10.3
174
71

75

43.2
0.57
16
2.78
10.7
183
78

44.5
0.60
15
2.81
10.8
185
79

39.9
0.42
12
2.69
10.3
176
75

43.3
0.43
12
2.76
10.6
182
77

67
44.6
0.45
11
2.78
10.7
183
78

46.3
0.37
11
2.88
11.1
191
83

47.7
0.39
10
2.90
11.2
193
84

71
-

37.8
0.87
21
2.81
11.0
184
70

39.0
0.91
20
2.83
11.1
185
70

34.3
0.74
18
2.71
10.5
176
67

37.2
0.76
18
2.78
10.9
182
69

59
38.3
0.80
17
2.81
11.0
184
70

42.2
0.59
16
2.97
11.6
209
81

43.4
0.62
15
2.99
11.7
211
82

39.0
0.43
12
2.87
11.2
200
78

42.2
0.44
12
2.94
11.5
207
80

45.2
0.38
11
3.07
12.1
218
86

46.6
0.40
10
3.09
12.2
220
87

35.9 38.9 41.8


0.75 0.57 0.36
19
16
11
2.80 2.89 2.99
10.9 11.3 11.7
192
202
211
72
79
84
(TVA) conditions

38.9
0.78
19
2.87
11.2
198
74

40.1
0.81
18
2.90
11.3
200
75

35.6
0.61
16
2.77
10.8
190
71

38.5
0.64
16
2.85
11.1
196
73

34.1
0.86
21
2.88
11.4
203
71

36.9
0.90
21
2.96
11.7
209
73

38.0
0.94
20
2.98
11.8
211
74

33.5
0.76
18
2.86
11.3
201
70

36.3
0.79
18
2.93
11.6
207
73

39.1
0.84
19
3.05
12.1
227
79
38.0
0.80
19
3.03
12.0
225
78
35.1
0.77
20
2.95
11.7
218
76

34.7
0.63
16
2.92
11.6
216
75

37.6
0.66
16
3.00
11.9
223
77

38.0
0.58
16
3.05
12.1
230
83

41.1
0.61
16
3.13
12.5
238
85

42.4
0.64
15
3.16
12.6
240
86

38.0
0.44
12
3.02
12.0
228
82

41.2
0.46
12
3.10
12.3
235
84

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
39.7 43.5
37.4
38.7
42.4
0.67 0.46
0.83
0.69
0.48
15
11
17
15
11
2.87 2.97
2.96
3.03
3.13
11.2 11.6
11.7
12.0
12.4
198
209
209
225
238
74
81
73
78
85

40.7
0.38
11
3.15
12.6
240
88

44.1
0.39
11
3.24
12.9
248
91

45.5
0.41
10
3.26
13.1
250
92

71
-

EXPANDED PERFORMANCE DATA

MBh
36.6 37.7 40.8 43.8 35.8 36.8 39.9 42.8 34.9
S/T
0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84
Delta T 21
19
16
11
21
19
16
11
21
1269
KW
2.38 2.43 2.51 2.60 2.57 2.63 2.71 2.80 2.74
AMPS 9.0
9.2
9.5
9.9
9.8
10.0 10.4 10.8 10.6
HI PR 140
150
159
165
157
168
178
186
178
LO PR
62
66
72
76
65
69
76
81
68
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA
High and low pressures are measured at the liquid and suction access fittings.

75

70

IDB*

MODEL: GPH1342H21*

32.4
0.90
21
3.01
12.2
228
75

35.1
0.93
21
3.09
12.5
235
77

36.1
0.97
20
3.11
12.6
238
78

31.8
0.79
18
2.98
12.0
226
74

34.5
0.82
18
3.06
12.4
233
76

59
35.5
0.86
17
3.09
12.5
235
77

33.3
0.80
19
3.08
12.5
246
79

36.1
0.83
19
3.16
12.8
253
82

37.2
0.87
18
3.19
13.0
256
83

33.0
0.66
16
3.05
12.3
243
78

35.7
0.68
15
3.13
12.7
251
81

63
36.8
0.72
15
3.16
12.8
253
82

36.1
0.61
16
3.18
12.9
259
87

39.1
0.63
16
3.27
13.3
267
89

40.2
0.66
15
3.29
13.4
270
90

36.1
0.46
12
3.15
12.8
257
86

39.1
0.47
12
3.24
13.2
265
88

67
40.3
0.50
11
3.27
13.3
267
89

105

38.7
0.39
11
3.29
13.4
270
92

41.9
0.40
11
3.38
13.8
279
95

43.2
0.42
10
3.41
13.9
282
96

71
-

30.0
0.90
20
3.12
12.9
252
77

32.5
0.94
19
3.20
13.3
260
79

33.4
0.98
19
3.23
13.4
262
80

29.5
0.80
17
3.09
12.8
250
76

31.9
0.82
17
3.17
13.2
257
79

59
32.9
0.86
16
3.20
13.3
260
79

30.9
0.81
18
3.19
13.2
271
82

33.4
0.84
18
3.27
13.6
280
85

34.4
0.88
17
3.30
13.8
282
85

30.5
0.66
15
3.16
13.1
269
81

33.1
0.69
14
3.24
13.5
277
84

63
34.1
0.72
14
3.27
13.6
280
85

33.4
0.61
15
3.30
13.7
286
90

36.2
0.63
15
3.38
14.1
295
92

37.3
0.67
14
3.41
14.2
298
93

33.5
0.46
11
3.27
13.6
284
89

36.3
0.48
11
3.35
14.0
292
91

67
37.3
0.50
11
3.38
14.1
295
92

115

35.8
0.39
10
3.41
14.2
299
95

38.8
0.41
10
3.50
14.7
308
98

40.0
0.43
10
3.53
14.8
311
99

71
-

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1342H21*

27

28

41.3
0.84
22
2.52
9.6
156
68

38.1
0.81
22
2.45
9.3
152
66

43.1
0.95
23
2.56
9.8
160
70

41.9
0.91
24
2.54
9.7
158
69

MBh
40.4
S/T
0.90
Delta T 23
KW
2.46
AMPS 9.4
HI PR 145
LO PR
64

MBh
37.3
S/T
0.86
Delta T 23
KW
2.40
AMPS 9.1
HI PR 141
LO PR
62

MBh
42.3
S/T
0.98
Delta T 23
KW
2.50
AMPS 9.5
HI PR 148
LO PR
65

MBh
41.1
S/T
0.94
Delta T 24
KW
2.48
AMPS 9.4
HI PR 147
LO PR
65

1450

1269

1631

1450

1631

63
42.5
0.88
21
2.54
9.7
158
69

59
MBh
41.6
S/T
0.94
Delta T 22
KW
2.48
AMPS 9.4
HI PR 147
LO PR
65

Airflow

65

43.9
0.82
23
2.62
10.0
167
75

45.2
0.86
22
2.64
10.1
168
76

40.7
0.66
19
2.53
9.6
160
72

44.1
0.68
19
2.60
9.9
165
75

67
45.4
0.72
18
2.62
10.0
167
75

46.8
0.66
20
2.71
10.4
174
80

48.2
0.70
19
2.73
10.5
176
81

43.5
0.49
16
2.62
10.0
167
77

47.1
0.51
15
2.68
10.3
172
79

71
48.5
0.54
15
2.71
10.4
174
80

40.1
0.97
25
2.68
10.2
165
69

41.3
1.00
23
2.70
10.3
166
69

36.4
0.90
24
2.59
9.9
158
66

39.4
0.93
23
2.66
10.1
163
68

59
40.6
1.00
23
2.68
10.2
165
69

40.9
0.94
24
2.74
10.5
177
73

42.1
0.98
23
2.76
10.6
179
74

37.2
0.84
23
2.65
10.1
170
70

40.3
0.87
22
2.72
10.4
175
72

63
41.5
0.91
21
2.74
10.5
177
73

75

42.8
0.85
23
2.83
10.9
187
80

44.1
0.89
22
2.86
11.0
189
80

39.7
0.68
20
2.74
10.5
180
76

43.1
0.71
19
2.81
10.8
185
79

67
44.3
0.74
19
2.83
10.9
187
80

45.7
0.69
20
2.93
11.3
195
85

47.1
0.72
19
2.95
11.4
197
86

42.5
0.51
16
2.83
10.9
187
81

46.0
0.53
15
2.90
11.2
193
84

71
47.4
0.56
15
2.93
11.3
195
85

39.2
1.00
25
2.86
11.2
187
71

40.3
1.00
23
2.88
11.3
189
72

35.5
0.92
24
2.76
10.7
180
68

38.5
0.95
23
2.83
11.1
185
70

59
39.6
1.00
22
2.86
11.2
187
71

41.8
0.87
23
3.02
11.8
213
83

43.1
0.91
22
3.04
12.0
215
84

38.8
0.70
20
2.92
11.4
204
79

42.0
0.73
19
2.99
11.7
211
82

44.6
0.71
20
3.12
12.3
222
88

45.9
0.74
19
3.15
12.4
224
89

41.5
0.52
16
3.02
11.8
213
85

44.9
0.54
15
3.10
12.2
220
87

36.9 38.6 41.2


0.93 0.84 0.68
25
23
20
2.85 2.94 3.04
11.1 11.5 12.0
196
206
215
73
80
85
Rating Conditions

39.9
0.96
24
2.92
11.4
202
76

41.1
1.00
23
2.95
11.6
204
77

36.3
0.86
23
2.82
11.0
194
73

39.3
0.89
22
2.90
11.3
200
75

35.3
0.99
25
2.93
11.6
207
73

38.2
1.00
24
3.01
12.0
213
75

39.4
1.00
22
3.04
12.1
215
76

34.7
0.95
24
2.91
11.5
205
72

37.6
0.98
23
2.98
11.9
211
74

36.0
0.96
25
3.00
11.9
223
77

39.0
0.99
25
3.08
12.3
230
80

40.1
1.00
23
3.11
12.4
232
80

35.4
0.89
23
2.97
11.8
220
76

38.4
0.92
22
3.05
12.2
227
79

37.7
0.86
24
3.10
12.3
235
84

40.8
0.90
23
3.18
12.7
242
87

42.0
0.94
22
3.21
12.8
245
88

37.8
0.72
20
3.07
12.2
233
83

41.0
0.75
19
3.16
12.6
240
86

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
40.5 43.3 46.3 38.7
39.5
42.2
0.94 0.76 0.57 1.00
0.97
0.79
21
19
15
22
22
19
2.92 3.02 3.12 3.01
3.08
3.18
11.4 11.8 12.3 12.0
12.3
12.7
202
213
222
213
230
242
76
83
88
75
80
87

40.2
0.70
20
3.21
12.8
245
90

43.5
0.73
20
3.29
13.2
253
93

44.8
0.76
19
3.32
13.3
255
93

40.5
0.54
16
3.18
12.7
243
89

43.8
0.56
16
3.26
13.1
250
92

71
45.1
0.59
15
3.29
13.2
253
93

EXPANDED PERFORMANCE DATA

MBh
37.9 38.6 40.5 43.2 37.0 37.7 39.5 42.2 36.2
S/T
0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96
Delta T 25
24
23
20
25
25
23
20
25
1269
KW
2.42 2.47 2.55 2.64 2.61 2.67 2.76 2.85 2.78
AMPS 9.2
9.4
9.7
10.1 10.0 10.2 10.6 11.0 10.8
HI PR 142
153
162
169
160
172
182
189
182
LO PR
63
67
73
78
66
71
77
82
69
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI
High and low pressures are measured at the liquid and suction access fittings.

85

80

IDB*

MODEL: GPH1342H21*

33.5
1.00
24
3.06
12.4
233
76

36.3
1.00
23
3.14
12.8
240
78

37.4
1.00
21
3.17
12.9
242
79

32.9
0.98
23
3.03
12.3
230
75

35.7
1.00
23
3.11
12.6
238
78

59
36.7
1.00
21
3.14
12.8
240
78

34.2
0.99
25
3.13
12.7
250
81

37.0
1.00
23
3.21
13.1
258
83

38.1
1.00
21
3.24
13.2
261
84

33.6
0.92
22
3.10
12.6
248
80

36.5
0.96
22
3.19
13.0
256
83

63
37.6
1.00
21
3.21
13.1
258
83

35.8
0.90
23
3.24
13.1
265
88

38.8
0.93
23
3.32
13.5
273
91

39.9
0.98
22
3.35
13.7
275
92

36.0
0.75
20
3.21
13.0
262
87

39.0
0.78
19
3.29
13.4
270
90

67
40.1
0.82
18
3.32
13.5
273
91

105

38.2
0.73
20
3.35
13.7
276
94

41.3
0.76
20
3.44
14.1
284
97

42.6
0.79
19
3.47
14.2
287
98

38.4
0.56
16
3.32
13.5
273
93

41.6
0.58
15
3.41
13.9
282
96

71
42.9
0.61
15
3.44
14.1
284
97

31.0
1.00
22
3.17
13.2
257
79

33.6
1.00
21
3.25
13.5
265
81

34.6
1.00
20
3.28
13.7
268
82

30.5
0.99
22
3.14
13.0
255
78

33.0
1.00
21
3.23
13.4
263
80

59
34.0
1.00
19
3.25
13.5
265
81

31.6
1.00
23
3.24
13.5
277
84

34.3
1.00
22
3.33
13.9
285
86

35.3
1.00
20
3.36
14.0
288
87

31.2
0.93
21
3.22
13.4
274
83

33.8
0.96
21
3.30
13.8
283
85

63
34.8
1.00
20
3.33
13.9
285
86

33.1
0.91
22
3.35
14.0
292
91

35.9
0.94
21
3.44
14.4
301
94

37.0
0.98
21
3.47
14.5
304
95

33.3
0.76
18
3.33
13.8
289
90

36.1
0.78
18
3.41
14.2
298
93

67
37.2
0.82
17
3.44
14.4
301
94

115

35.4
0.73
19
3.47
14.5
305
97

38.3
0.76
18
3.56
14.9
314
100

39.4
0.80
18
3.60
15.1
317
101

35.6
0.57
15
3.44
14.4
302
96

38.6
0.59
14
3.53
14.8
311
99

71
39.7
0.62
14
3.56
14.9
314
100

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1342H21*

44.1
0.72
18
2.77
10.6
145
63

40.7
0.69
18
2.70
10.3
141
61

46.2
0.86
20
2.82
10.8
148
64

44.9
0.82
20
2.80
10.7
147
64

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

1650

1444

1856

1650

1856

59
45.5
0.75
17
2.80
10.7
147
64

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

Airflow

46.2
0.73
19
2.86
11.0
158
68

47.6
0.77
18
2.88
11.1
160
68

42.2
0.58
16
2.76
10.6
152
65

45.8
0.60
15
2.83
10.9
156
67

63
47.1
0.63
15
2.86
11.0
158
68

65

50.0
0.55
15
2.95
11.4
167
74

51.5
0.58
15
2.98
11.5
169
75

46.3
0.40
12
2.85
10.9
160
71

50.1
0.42
12
2.93
11.3
165
73

67
51.6
0.44
11
2.95
11.4
167
74

53.7
0.36
11
3.06
11.8
174
79

55.3
0.37
10
3.08
11.9
176
79

71
-

43.8
0.85
21
3.02
11.6
165
67

45.2
0.89
20
3.05
11.7
166
68

39.8
0.72
18
2.92
11.2
158
64

43.1
0.74
18
3.00
11.5
163
66

59
44.4
0.78
17
3.02
11.6
165
67

45.1
0.76
19
3.09
11.9
177
71

46.5
0.79
18
3.12
12.0
179
72

41.2
0.60
16
2.99
11.5
170
69

44.7
0.62
15
3.07
11.8
176
71

63
46.0
0.65
15
3.09
11.9
177
71

75

48.9
0.57
16
3.20
12.3
187
78

50.3
0.60
15
3.23
12.5
189
79

45.2
0.42
12
3.09
11.9
180
75

49.0
0.43
12
3.17
12.2
185
77

67
50.4
0.45
11
3.20
12.3
187
78

52.4
0.37
11
3.31
12.8
195
83

54.0
0.39
10
3.34
12.9
197
84

71
-

42.8
0.87
21
3.23
12.7
187
70

44.1
0.91
20
3.25
12.8
189
70

38.8
0.74
18
3.12
12.2
180
67

42.1
0.76
18
3.20
12.6
186
69

59
43.4
0.80
17
3.23
12.7
187
70

47.7
0.59
16
3.41
13.5
213
81

49.1
0.62
15
3.44
13.6
215
82

44.1
0.43
12
3.30
12.9
204
78

47.8
0.44
12
3.38
13.3
211
80

51.2
0.38
11
3.53
14.0
222
86

52.7
0.40
10
3.56
14.1
224
87

40.7 44.0 47.3


0.75 0.57 0.36
19
16
11
3.21 3.32 3.44
12.6 13.1 13.6
196
207
215
72
79
84
(TVA) conditions

44.1
0.78
19
3.30
13.0
202
74

45.4
0.81
18
3.33
13.1
204
75

40.3
0.61
16
3.19
12.5
194
71

43.6
0.64
15
3.27
12.9
200
73

38.5
0.86
21
3.32
13.2
207
71

41.8
0.90
21
3.40
13.6
213
73

43.0
0.94
20
3.43
13.7
216
74

37.9
0.76
18
3.29
13.1
205
70

41.1
0.79
18
3.37
13.5
211
73

44.3
0.84
18
3.51
14.1
232
79
43.0
0.80
19
3.48
13.9
230
78
39.7
0.77
20
3.39
13.5
223
76

39.3
0.63
16
3.36
13.4
221
75

42.6
0.66
16
3.45
13.8
227
77

43.0
0.58
16
3.51
14.0
235
83

46.5
0.61
16
3.60
14.4
243
85

47.9
0.64
15
3.64
14.6
245
86

43.0
0.44
12
3.48
13.9
233
82

46.6
0.46
12
3.57
14.3
240
84

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
44.9 49.2
42.3
43.8
48.0
0.67 0.46
0.83
0.69
0.48
15
11
17
15
11
3.30 3.41
3.40
3.48
3.60
13.0 13.5
13.6
13.9
14.4
202
213
213
230
243
74
81
73
78
85

46.1
0.38
11
3.63
14.6
245
88

49.9
0.39
11
3.73
15.0
253
91

51.4
0.41
10
3.76
15.1
256
92

71
-

EXPANDED PERFORMANCE DATA

MBh
41.4 42.7 46.2 49.6 40.5 41.7 45.1 48.4 39.5
S/T
0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84
Delta T 21
19
16
11
21
19
16
11
21
1444
KW
2.73 2.79 2.88 2.98 2.95 3.01 3.12 3.22 3.14
AMPS 10.4 10.7 11.0 11.5 11.3 11.6 12.0 12.5 12.3
HI PR 142
153
162
169
160
172
182
189
182
LO PR
62
66
72
76
65
69
76
81
68
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA
High and low pressures are measured at the liquid and suction access fittings.

75

70

IDB*

MODEL: G PH1348H21*

36.6
0.90
21
3.46
14.1
233
75

39.7
0.93
21
3.56
14.5
240
77

40.9
0.97
20
3.59
14.6
243
78

36.0
0.79
18
3.43
14.0
231
74

39.0
0.82
18
3.52
14.4
238
76

59
40.2
0.86
17
3.56
14.5
240
77

37.7
0.80
19
3.54
14.5
251
79

40.8
0.83
19
3.64
14.9
258
82

42.1
0.87
18
3.67
15.0
261
83

37.3
0.66
16
3.51
14.3
248
78

40.4
0.68
15
3.61
14.7
256
81

63
41.6
0.72
15
3.64
14.9
258
82

40.8
0.61
16
3.67
15.0
265
87

44.2
0.63
16
3.77
15.4
273
89

45.5
0.66
15
3.80
15.5
276
90

40.9
0.46
12
3.63
14.8
262
86

44.3
0.47
12
3.73
15.3
270
88

67
45.6
0.50
11
3.76
15.4
273
89

105

43.8
0.39
11
3.79
15.5
276
92

47.5
0.40
11
3.90
16.0
285
95

48.9
0.42
10
3.93
16.2
287
96

71
-

33.9
0.90
20
3.59
15.0
257
77

36.7
0.94
19
3.69
15.4
265
79

37.9
0.98
18
3.72
15.6
268
80

33.4
0.80
17
3.56
14.8
255
76

36.1
0.82
17
3.65
15.3
263
79

59
37.2
0.86
16
3.69
15.4
265
79

34.9
0.81
18
3.67
15.3
277
82

37.8
0.84
18
3.77
15.8
286
85

39.0
0.88
17
3.81
16.0
288
85

34.6
0.66
15
3.64
15.2
274
81

37.5
0.69
14
3.74
15.7
283
84

63
38.6
0.72
14
3.77
15.8
285
85

37.8
0.61
15
3.80
15.9
292
90

41.0
0.63
14
3.90
16.4
301
92

42.2
0.67
14
3.94
16.5
305
93

37.9
0.46
11
3.77
15.7
289
89

41.0
0.48
11
3.87
16.2
298
91

67
42.3
0.50
10
3.90
16.4
301
92

115

40.6
0.39
10
3.94
16.5
305
95

44.0
0.41
10
4.04
17.0
314
98

45.3
0.43
10
4.08
17.2
318
99

71
-

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1348H21*

29

30

45.7
0.90
23
2.82
10.8
148
64

42.2
0.86
23
2.75
10.5
144
62

47.9
0.98
23
2.87
11.0
151
65

46.5
0.94
24
2.84
10.9
150
65

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

1650

1444

1856

1650

1856

59
47.1
0.94
22
2.84
10.9
150
65

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

Airflow

47.4
0.91
24
2.91
11.2
161
69

48.8
0.95
23
2.93
11.3
163
70

43.1
0.81
22
2.81
10.8
155
66

46.7
0.84
22
2.88
11.1
160
68

63
48.1
0.88
21
2.91
11.2
161
69

65

49.6
0.82
23
3.01
11.6
170
75

51.1
0.86
22
3.03
11.7
172
76

46.0
0.66
19
2.90
11.1
164
72

49.9
0.68
19
2.98
11.5
169
75

67
51.4
0.72
18
3.01
11.6
170
75

52.9
0.66
20
3.11
12.0
178
80

54.5
0.70
19
3.13
12.2
179
81

49.2
0.49
15
3.00
11.6
171
77

53.3
0.51
15
3.08
11.9
176
79

71
54.9
0.54
15
3.11
12.0
178
80

45.4
0.97
25
3.08
11.9
168
69

46.8
1.00
23
3.10
12.0
170
69

41.2
0.90
23
2.97
11.4
161
66

44.6
0.93
23
3.05
11.7
166
68

59
46.0
1.00
23
3.08
11.9
168
69

46.3
0.94
24
3.15
12.2
181
73

47.7
0.98
23
3.17
12.3
183
74

42.1
0.84
22
3.04
11.7
174
70

45.6
0.87
22
3.12
12.0
179
72

63
47.0
0.91
21
3.15
12.2
181
73

75

48.5
0.85
23
3.25
12.6
191
80

49.9
0.89
22
3.28
12.7
193
80

45.0
0.68
20
3.14
12.1
183
76

48.7
0.71
19
3.23
12.5
189
79

67
50.2
0.74
18
3.25
12.6
191
80

51.7
0.69
20
3.37
13.1
199
85

53.3
0.72
19
3.40
13.2
201
86

48.1
0.51
16
3.25
12.6
191
81

52.1
0.53
15
3.34
12.9
197
84

71
53.6
0.56
15
3.37
13.1
199
85

44.3
1.00
25
3.28
12.9
191
71

45.7
1.00
23
3.31
13.1
193
72

40.2
0.92
24
3.17
12.4
184
68

43.6
0.95
23
3.25
12.8
189
70

59
44.9
1.00
22
3.28
12.9
191
71

47.3
0.87
23
3.47
13.7
217
83

48.7
0.91
22
3.50
13.9
219
84

43.9
0.70
20
3.35
13.2
209
79

47.6
0.73
19
3.44
13.6
215
82

50.5
0.71
20
3.60
14.3
227
88

52.0
0.74
19
3.63
14.4
229
89

46.9
0.52
16
3.47
13.7
218
85

50.8
0.54
15
3.56
14.1
224
87

41.7 43.7 46.6


0.93 0.84 0.68
25
23
20
3.27 3.38 3.50
12.9 13.3 13.8
200
211
220
73
80
85
Rating Conditions

45.2
0.96
24
3.36
13.3
206
76

46.5
1.00
23
3.39
13.4
208
77

41.1
0.86
23
3.24
12.8
198
73

44.5
0.89
22
3.33
13.1
204
75

39.9
0.99
25
3.37
13.5
211
73

43.2
1.00
24
3.46
13.9
218
75

44.5
1.00
22
3.49
14.0
220
76

39.2
0.95
24
3.34
13.3
209
72

42.5
0.98
23
3.43
13.7
216
74

40.7
0.96
25
3.45
13.8
227
77

44.1
0.99
24
3.55
14.2
234
80

45.4
1.00
22
3.58
14.4
237
80

40.1
0.89
23
3.42
13.7
225
76

43.4
0.92
22
3.51
14.1
232
79

42.6
0.86
23
3.57
14.3
240
84

46.2
0.90
23
3.67
14.7
247
87

47.6
0.94
22
3.70
14.9
250
88

42.8
0.72
20
3.54
14.2
238
83

46.4
0.75
19
3.64
14.6
245
86

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
45.9 49.0 52.4 43.8
44.7
47.8
0.94 0.76 0.57 1.00
0.97
0.79
21
18
15
22
21
19
3.36 3.47 3.60 3.46
3.55
3.67
13.3 13.7 14.3 13.9
14.2
14.7
206
217
227
218
234
247
76
83
88
75
80
87

45.5
0.70
20
3.70
14.8
250
90

49.3
0.73
20
3.80
15.3
258
93

50.7
0.76
19
3.83
15.4
261
93

45.8
0.54
16
3.66
14.7
248
89

49.6
0.56
15
3.76
15.1
256
92

71
51.1
0.59
15
3.80
15.3
258
93

EXPANDED PERFORMANCE DATA

MBh
42.9 43.7 45.8 48.9 41.9 42.7 44.7 47.7 40.9
S/T
0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96
Delta T 25
24
23
20
25
25
23
20
25
1444
KW
2.77 2.83 2.93 3.03 3.00 3.07 3.17 3.28 3.20
AMPS 10.6 10.9 11.3 11.7 11.5 11.8 12.2 12.7 12.6
HI PR 145
156
165
172
163
175
185
193
185
LO PR
63
67
73
78
66
71
77
82
69
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI
High and low pressures are measured at the liquid and suction access fittings.

85

80

IDB*

MODEL: G PH1348H21*

37.9
1.00
24
3.52
14.4
238
76

41.1
1.00
23
3.62
14.8
245
78

42.3
1.00
21
3.65
14.9
247
79

37.3
0.98
23
3.49
14.2
235
75

40.4
1.00
22
3.59
14.7
243
78

59
41.6
1.00
21
3.62
14.8
245
78

38.7
0.99
24
3.61
14.7
256
81

41.9
1.00
23
3.70
15.2
264
83

43.1
1.00
21
3.74
15.3
266
84

38.1
0.92
22
3.57
14.6
253
80

41.3
0.96
22
3.67
15.0
261
83

63
42.5
1.00
21
3.70
15.2
264
83

40.5
0.90
23
3.73
15.2
270
88

43.9
0.93
23
3.83
15.7
278
91

45.2
0.98
22
3.87
15.9
281
92

40.7
0.75
19
3.70
15.1
267
87

44.1
0.78
19
3.80
15.6
276
90

67
45.4
0.82
18
3.83
15.7
278
91

105

43.2
0.73
20
3.86
15.8
282
94

46.8
0.76
20
3.97
16.3
290
97

48.2
0.79
19
4.00
16.5
293
98

43.5
0.56
16
3.83
15.7
279
93

47.1
0.58
15
3.93
16.2
287
96

71
48.5
0.61
15
3.97
16.3
290
97

35.1
1.00
22
3.65
15.3
263
79

38.1
1.00
21
3.75
15.7
271
81

39.2
1.00
19
3.79
15.9
273
82

34.5
0.99
22
3.62
15.1
260
78

37.4
1.00
21
3.72
15.6
268
80

59
38.5
1.00
19
3.75
15.7
271
81

35.8
1.00
23
3.74
15.6
283
84

38.8
1.00
22
3.84
16.1
291
86

40.0
1.00
20
3.87
16.3
294
87

35.3
0.93
21
3.71
15.5
280
83

38.2
0.96
21
3.81
16.0
288
85

63
39.4
1.00
19
3.84
16.1
291
86

37.5
0.91
22
3.87
16.2
298
91

40.6
0.94
21
3.98
16.7
308
94

41.8
0.98
20
4.01
16.8
311
95

37.7
0.76
18
3.83
16.0
295
90

40.8
0.78
18
3.94
16.5
305
93

67
42.1
0.82
17
3.98
16.7
308
94

115

40.0
0.73
19
4.01
16.8
311
97

43.3
0.76
18
4.12
17.3
321
100

44.6
0.80
18
4.15
17.5
324
101

40.3
0.57
15
3.97
16.7
308
96

43.6
0.59
14
4.08
17.2
318
99

71
45.0
0.62
14
4.12
17.3
321
100

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1348H21*

54.8
0.72
19
3.62
14.0
157
61

50.6
0.69
19
3.52
13.6
153
59

57.4
0.86
21
3.68
14.3
160
62

55.7
0.82
22
3.65
14.1
159
61

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

1900

1663

2138

1900

2138

59
56.4
0.75
18
3.65
14.1
159
61

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

Airflow

57.4
0.73
20
3.74
14.5
171
65

59.1
0.77
19
3.77
14.6
173
66

52.4
0.58
17
3.61
13.9
164
63

56.8
0.60
16
3.70
14.3
169
65

63
58.5
0.63
16
3.74
14.5
171
65

65

62.1
0.55
17
3.87
15.0
180
71

64.0
0.58
16
3.90
15.1
182
72

57.4
0.40
13
3.73
14.4
173
68

62.2
0.42
13
3.83
14.8
179
71

67
64.1
0.44
12
3.87
15.0
180
71

66.7
0.36
11
4.00
15.6
188
76

68.7
0.37
11
4.04
15.7
190
77

71
-

54.4
0.85
22
3.96
15.3
178
65

56.1
0.89
21
4.00
15.5
180
65

49.4
0.72
20
3.82
14.8
171
62

53.5
0.74
19
3.93
15.2
176
64

59
55.1
0.78
19
3.96
15.3
178
65

56.0
0.76
21
4.06
15.7
192
69

57.7
0.79
20
4.09
15.9
194
70

51.2
0.60
17
3.91
15.1
184
66

55.5
0.62
17
4.02
15.6
190
68

63
57.1
0.65
16
4.06
15.7
192
69

75

60.7
0.57
17
4.20
16.3
203
75

62.5
0.60
16
4.24
16.4
205
76

56.1
0.42
13
4.05
15.7
194
72

60.8
0.43
13
4.16
16.1
200
75

67
62.6
0.45
12
4.20
16.3
202
75

65.1
0.37
12
4.35
16.9
211
80

67.1
0.39
11
4.39
17.1
213
81

71
-

53.1
0.87
22
4.24
16.8
203
67

54.7
0.91
21
4.28
16.9
205
68

48.2
0.74
20
4.09
16.1
195
65

52.3
0.76
19
4.20
16.6
201
67

59
53.8
0.80
19
4.24
16.8
203
67

59.2
0.59
17
4.49
17.8
230
78

61.0
0.62
16
4.53
18.0
233
79

54.8
0.43
13
4.33
17.1
221
75

59.3
0.44
13
4.45
17.6
228
77

50.5
54.7
0.75
0.57
21
17
4.22
4.37
16.7
17.3
212
223
70
76
(TVA) conditions

54.7
0.78
21
4.34
17.2
218
72

56.4
0.81
20
4.38
17.4
220
72

50.0
0.61
17
4.18
16.5
209
69

54.2
0.64
17
4.30
17.0
216
71

58.7
0.36
12
4.53
18.0
233
81

63.6
0.38
12
4.66
18.5
240
83

65.5
0.40
11
4.70
18.7
243
84

47.8
0.86
23
4.36
17.5
224
69

51.8
0.90
22
4.48
18.0
231
71

53.4
0.94
22
4.52
18.1
233
71

47.1
0.76
20
4.32
17.3
222
68

51.0
0.79
19
4.44
17.8
229
70

55.0
0.84
20
4.63
18.6
251
76
53.4
0.80
21
4.59
18.4
248
75
49.3
0.77
21
4.46
17.9
241
73

48.8
0.63
17
4.42
17.7
239
72

52.8
0.66
17
4.55
18.3
246
75

53.3
0.58
17
4.62
18.5
254
80

57.8
0.61
17
4.75
19.1
262
82

59.5
0.64
16
4.80
19.3
265
83

53.4
0.44
13
4.58
18.3
252
79

57.9
0.46
13
4.71
18.9
260
81

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
55.8
61.1
52.5
54.4
59.6
0.67
0.46
0.83
0.69
0.48
16
12
19
16
12
4.34
4.49
4.48
4.59
4.75
17.2
17.8
18.0
18.4
19.1
218
230
231
248
262
72
78
71
75
82

57.2
0.38
12
4.79
19.3
265
85

62.0
0.39
12
4.93
19.8
274
88

63.9
0.41
11
4.97
20.0
276
88

71
-

EXPANDED PERFORMANCE DATA

MBh
51.4 53.0 57.3 61.5 50.2 51.7 56.0 60.1 49.0
S/T
0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84
Delta T 22
21
17
12
23
21
17
12
23
1663
KW
3.55 3.64 3.76 3.90 3.86 3.95 4.09 4.23 4.12
AMPS 13.7 14.1 14.6 15.1 14.9 15.3 15.8 16.4 16.3
HI PR 154
166
175
183
173
186
196
205
197
LO PR 59
63
69
74
63
67
73
78
65
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA
High and low pressures are measured at the liquid and suction access fittings.

75

70

IDB*

MODEL: GPH1360H21*

45.5
0.90
23
4.56
18.6
252
72

49.2
0.93
22
4.69
19.2
260
74

50.7
0.97
21
4.73
19.4
262
75

44.7
0.79
19
4.52
18.4
249
71

48.4
0.82
19
4.64
19.0
257
73

59
49.9
0.86
18
4.69
19.2
260
74

46.8
0.80
21
4.67
19.1
271
77

50.7
0.83
20
4.80
19.7
280
79

52.2
0.87
20
4.84
19.9
282
80

46.3
0.66
17
4.63
18.9
268
76

50.2
0.68
17
4.76
19.5
277
78

63
51.7
0.72
16
4.80
19.7
279
79

50.7
0.61
17
4.84
19.8
286
84

54.9
0.63
17
4.97
20.4
295
86

56.5
0.66
16
5.02
20.6
298
87

50.8
0.46
13
4.79
19.6
283
83

55.0
0.47
13
4.93
20.2
292
85

67
56.6
0.50
12
4.97
20.4
295
86

105

54.4
0.39
12
5.01
20.6
299
89

58.9
0.40
12
5.15
21.2
308
92

60.7
0.42
11
5.20
21.4
311
93

71
-

42.1
0.90
21
4.73
19.8
278
74

45.6
0.94
21
4.86
20.4
287
77

47.0
0.98
20
4.91
20.6
290
77

41.4
0.80
18
4.69
19.6
276
74

44.9
0.82
18
4.82
20.2
284
76

59
46.2
0.86
17
4.86
20.4
287
77

43.4
0.81
19
4.85
20.3
300
79

47.0
0.84
19
4.98
20.9
309
82

48.4
0.88
18
5.03
21.1
312
82

42.9
0.66
16
4.80
20.1
297
78

46.5
0.69
15
4.94
20.7
306
81

63
47.9
0.72
15
4.98
20.9
309
82

46.9
0.61
16
5.02
21.0
316
86

50.8
0.63
16
5.16
21.7
326
89

52.4
0.67
15
5.21
21.9
329
90

47.0
0.46
12
4.97
20.8
313
86

50.9
0.48
12
5.11
21.4
323
88

67
52.5
0.50
11
5.16
21.7
326
89

115

50.4
0.39
11
5.20
21.9
330
92

54.6
0.41
11
5.35
22.5
340
95

56.2
0.43
10
5.40
22.7
344
96

71
-

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1360H21*

31

32

56.7
0.90
25
3.68
14.3
160
62

52.4
0.86
25
3.59
13.9
156
60

59.4
0.98
25
3.75
14.5
164
63

57.7
0.94
26
3.72
14.4
162
63

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

1900

1663

2138

1900

2138

59
58.4
0.94
24
3.72
14.4
162
63

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

Airflow

58.8
0.91
26
3.80
14.8
174
67

60.6
0.95
25
3.84
14.9
176
67

53.5
0.81
24
3.67
14.2
167
64

58.0
0.84
24
3.77
14.6
173
66

63
59.7
0.88
23
3.80
14.8
174
67

65

61.6
0.82
24
3.94
15.3
184
73

63.5
0.86
23
3.97
15.4
186
73

57.2
0.66
21
3.80
14.7
177
70

61.9
0.68
20
3.90
15.1
182
72

67
63.8
0.72
20
3.94
15.3
184
73

65.7
0.66
21
4.08
15.9
192
77

67.7
0.70
20
4.11
16.0
194
78

61.1
0.49
17
3.93
15.3
184
74

66.2
0.51
16
4.04
15.7
190
77

71
68.2
0.54
16
4.08
15.9
192
77

56.4
0.97
27
4.03
15.6
182
66

58.1
1.00
25
4.07
15.8
184
67

51.1
0.90
25
3.89
15.0
175
63

55.4
0.93
25
4.00
15.5
180
65

59
57.1
1.00
25
4.03
15.6
182
66

57.5
0.94
26
4.13
16.0
196
70

59.2
0.98
25
4.17
16.2
198
71

52.3
0.84
24
3.98
15.4
188
68

56.6
0.87
24
4.09
15.9
194
70

63
58.3
0.91
23
4.13
16.0
196
70

75

60.2
0.85
25
4.28
16.6
207
77

62.0
0.89
24
4.31
16.8
209
78

55.8
0.68
21
4.12
16.0
198
74

60.5
0.71
21
4.24
16.4
205
76

67
62.3
0.74
20
4.28
16.6
207
77

64.2
0.69
21
4.43
17.3
216
82

66.1
0.72
21
4.47
17.4
218
83

59.7
0.51
17
4.27
16.6
207
79

64.7
0.53
17
4.39
17.1
213
81

71
66.6
0.56
16
4.43
17.3
216
82

55.0
1.00
27
4.31
17.1
207
69

56.7
1.00
24
4.35
17.2
209
69

49.9
0.92
25
4.16
16.4
199
66

54.1
0.95
25
4.28
16.9
205
68

59
55.7
1.00
24
4.31
17.1
207
69

56.1
0.96
26
4.42
17.5
223
73

57.8
1.00
25
4.46
17.7
225
74

51.0
0.86
24
4.26
16.8
214
70

55.3
0.89
24
4.38
17.4
220
72

58.7
0.87
25
4.58
18.1
235
80

60.5
0.91
24
4.62
18.3
237
81

54.5
0.70
21
4.41
17.4
226
77

59.0
0.73
21
4.53
18.0
233
79

57.8
0.68
22
4.61
18.3
238
82

62.7
0.71
21
4.74
18.9
245
85

64.6
0.74
21
4.78
19.0
248
86

58.3
0.52
17
4.57
18.1
235
82

63.1
0.54
17
4.70
18.7
243
84

49.5
0.99
27
4.44
17.8
228
70

53.7
1.00
26
4.56
18.3
236
72

55.3
1.00
24
4.60
18.5
238
73

48.7
0.95
26
4.40
17.6
226
69

52.8
0.98
25
4.52
18.1
233
71

50.5
0.96
27
4.55
18.2
246
74

54.7
0.99
26
4.67
18.8
253
77

56.4
1.00
24
4.71
19.0
256
78

49.8
0.89
24
4.50
18.1
243
74

53.9
0.92
24
4.63
18.6
251
76

52.9
0.86
25
4.71
18.9
260
81

57.3
0.90
25
4.84
19.5
268
84

59.0
0.94
24
4.88
19.6
270
85

53.2
0.72
21
4.67
18.7
257
81

57.6
0.75
21
4.80
19.3
265
83

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
56.9
60.8 65.0 54.3
55.5
59.3
0.94
0.76 0.57 1.00
0.97
0.79
23
20
16
23
23
20
4.42
4.58 4.74 4.56
4.67
4.84
17.5
18.1 18.9 18.3
18.8
19.5
223
235
245
236
253
268
73
80
85
72
77
84

56.4
0.70
22
4.88
19.6
271
87

61.1
0.73
22
5.02
20.2
279
89

63.0
0.76
21
5.06
20.4
282
90

56.8
0.54
17
4.83
19.5
268
86

61.6
0.56
17
4.97
20.0
276
88

71
63.4
0.59
16
5.02
20.2
279
89

EXPANDED PERFORMANCE DATA

MBh
53.3 54.3 56.9 60.7 52.0 53.0 55.5 59.3 50.8
51.8
54.2
S/T
0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96
0.93
0.84
Delta T 27
26
25
21
27
27
25
22
27
27
25
1663
KW
3.62 3.70 3.83 3.97 3.93 4.02 4.16 4.31 4.20
4.30
4.45
AMPS 14.0 14.3 14.8 15.4 15.2 15.6 16.1 16.8 16.6
17.0
17.6
HI PR 157
169
179
186
176
190
200
209
201
216
228
LO PR 61
65
71
75
64
68
74
79
67
71
77
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI Rating Conditions
High and low pressures are measured at the liquid and suction access fittings.

85

80

IDB*

MODEL: GPH1360H21*

47.1
1.00
26
4.64
19.0
257
73

51.0
1.00
25
4.77
19.6
265
76

52.5
1.00
23
4.82
19.8
268
76

46.3
0.98
25
4.60
18.8
254
73

50.1
1.00
24
4.73
19.4
262
75

59
51.6
1.00
22
4.77
19.6
265
76

48.0
0.99
26
4.75
19.5
277
78

52.0
1.00
25
4.89
20.1
285
80

53.5
1.00
23
4.93
20.3
288
81

47.3
0.92
24
4.71
19.3
274
77

51.2
0.96
24
4.84
19.9
282
80

63
52.8
1.00
23
4.89
20.1
285
80

50.3
0.90
25
4.93
20.2
292
85

54.4
0.93
25
5.06
20.8
301
88

56.1
0.98
24
5.11
21.0
304
89

50.5
0.75
21
4.88
20.0
289
84

54.7
0.78
21
5.02
20.6
298
87

67
56.4
0.82
20
5.06
20.8
301
88

105

53.6
0.73
22
5.10
21.0
305
91

58.1
0.76
21
5.25
21.6
314
94

59.8
0.79
20
5.30
21.8
317
94

54.0
0.56
17
5.06
20.8
302
90

58.5
0.58
16
5.20
21.4
311
93

71
60.3
0.61
16
5.25
21.6
314
94

43.6
1.00
24
4.82
20.2
284
76

47.2
1.00
23
4.95
20.8
293
78

48.7
1.00
21
5.00
21.0
296
79

42.9
0.99
23
4.78
20.0
281
75

46.4
1.00
22
4.91
20.6
290
77

59
47.8
1.00
21
4.95
20.8
293
78

44.4
1.00
25
4.94
20.7
306
81

48.2
1.00
23
5.07
21.3
315
83

49.6
1.00
21
5.12
21.5
318
84

43.8
0.93
23
4.89
20.5
303
80

47.4
0.96
22
5.03
21.1
312
82

63
48.9
1.00
21
5.07
21.3
315
83

46.6
0.91
23
5.11
21.4
323
88

50.4
0.94
23
5.26
22.1
333
91

51.9
0.98
22
5.31
22.3
336
92

46.8
0.76
20
5.07
21.2
320
87

50.7
0.78
19
5.21
21.9
329
90

67
52.2
0.82
18
5.26
22.1
333
91

115

49.7
0.73
20
5.30
22.3
337
94

53.8
0.76
20
5.45
23.0
347
97

55.4
0.80
19
5.50
23.2
350
98

50.0
0.57
16
5.25
22.1
333
93

54.2
0.59
15
5.40
22.7
344
96

71
55.8
0.62
15
5.45
23.0
347
97

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1360H21*

22.8
0.73
17
1.77
7.0
139
63

21.1
0.70
17
1.73
6.9
135
61

23.9
0.87
19
1.79
7.1
142
64

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

900

788

1013

1013

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

59

23.5
0.76
16
1.78
7.1
141
64

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

Airflow

63

24.6
0.77
17
1.82
7.3
153
68

21.8
0.58
15
1.76
7.0
146
65

23.7
0.61
15
1.80
7.2
150
67

24.4
0.64
14
1.81
7.2
152
68

65
67

26.7
0.59
14
1.87
7.5
162
75

23.9
0.41
11
1.81
7.2
154
71

25.9
0.42
11
1.85
7.3
158
73

26.7
0.44
11
1.86
7.4
160
74

28.6
0.38
10
1.93
7.7
169
79

71

59

23.4
0.90
19
1.91
7.6
160
68

20.6
0.73
17
1.84
7.3
152
64

22.3
0.75
17
1.88
7.5
156
66

23.0
0.79
16
1.90
7.5
158
67

63

24.1
0.80
18
1.95
7.8
172
72

21.3
0.61
15
1.88
7.5
163
69

23.1
0.63
15
1.92
7.6
168
71

23.8
0.66
14
1.93
7.7
170
71

75
67

26.0
0.61
14
2.00
8.0
181
79

23.4
0.42
11
1.93
7.7
172
75

25.3
0.44
11
1.97
7.9
178
77

26.1
0.46
11
1.99
7.9
180
78

27.9
0.39
10
2.06
8.2
189
84

71

59

22.8
0.92
19
2.02
8.2
182
70

20.1
0.74
17
1.94
7.8
173
67

21.8
0.77
17
1.99
8.0
178
69

22.4
0.81
16
2.00
8.1
180
70

23.5
0.82
18
2.05
8.3
195
75

20.8
0.62
15
1.98
8.0
186
71

22.6
0.64
15
2.03
8.2
191
73

23.2
0.68
14
2.04
8.3
193
74

25.4
0.62
14
2.11
8.6
206
82

22.8
0.43
11
2.04
8.2
196
78

24.7
0.45
11
2.08
8.4
202
80

25.5
0.47
11
2.10
8.5
204
81

27.3
0.40
10
2.18
8.9
215
87

22.2
0.95
19
2.11
8.7
207
74

19.6
0.77
18
2.03
8.3
197
70

21.2
0.80
17
2.08
8.5
203
73

21.9
0.84
17
2.09
8.6
205
73

22.9
0.85
18
2.15
8.8
223
79

20.3
0.64
15
2.07
8.5
212
75

22.0
0.67
15
2.12
8.7
218
77

22.7
0.70
14
2.13
8.8
220
78

24.1
0.61
15
2.20
9.0
233
85
22.2
0.59
15
2.15
8.8
226
83

24.8
0.64
14
2.21
9.1
235
86

22.3
0.44
12
2.13
8.7
223
82

24.1
0.46
11
2.18
9.0
230
84

24.8
0.48
11
2.20
9.0
233
85

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67

25.8
0.39
10
2.26
9.3
243
91
23.8
0.38
11
2.21
9.1
235
88

26.6
0.41
10
2.28
9.4
245
92

71

EXPANDED PERFORMANCE DATA

MBh
23.2 23.9 25.9 27.8 22.7 23.4 25.3 27.1 22.1
22.8
24.7 26.5 21.6
22.2
S/T
0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88
0.78
0.59 0.38 0.91
0.81
Delta T 20
18
15
10
20
18
15
10
20
18
15
10
20
18
2.13
75
900
KW
1.78 1.81 1.86 1.91 1.90 1.93 1.99 2.04 2.00
2.04
2.10 2.16 2.09
8.8
AMPS 7.1
7.2
7.4
7.6
7.5
7.7
7.9
8.2
8.1
8.3
8.5
8.8
8.6
HI PR 141
152
160
167
158
170
180
187
180
193
204
213
205
220
78
LO PR 64
68
74
79
67
71
78
83
70
74
81
86
73
MBh
21.4 22.1 23.9 25.6 20.9 21.6 23.3 25.0 20.4
21.0
22.8 24.4 19.9
20.5
S/T
0.80 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.85
0.76
0.57 0.37 0.87
0.78
Delta T 20
18
15
10
20
19
15
11
20
19
15
11
20
19
788
KW
1.74 1.77 1.82 1.87 1.86 1.89 1.94 2.00 1.96
2.00
2.05 2.11 2.05
2.09
8.6
AMPS 6.9
7.0
7.2
7.5
7.4
7.5
7.7
8.0
7.9
8.1
8.3
8.6
8.4
214
HI PR 137
147
155
162
153
165
174
182
174
188
198
207
199
76
LO PR 62
66
72
76
65
69
76
81
68
72
79
84
71
Shaded area is ACCA (TVA) conditions
IDB: Entering Indoor Dry Bulb Temperature KW=Total system power
High and low pressures are measured at the liquid and suction access fittings.

70

IDB*

MODEL: GPH1324M21A

59

20.5
0.94
20
2.17
9.1
230
77
18.9
0.91
20
2.12
8.8
223
75

21.1
0.99
19
2.19
9.1
233
78

18.6
0.80
17
2.11
8.8
221
74

20.2
0.83
17
2.16
9.0
228
76

20.8
0.87
16
2.17
9.1
230
77

63

21.1
0.84
18
2.22
9.3
248
82
19.5
0.81
18
2.17
9.0
240
79

21.8
0.88
17
2.23
9.3
250
83

19.3
0.67
15
2.15
9.0
238
78

20.9
0.69
15
2.20
9.2
245
81

21.5
0.72
14
2.22
9.3
248
82

67

22.9
0.64
15
2.28
9.5
262
89
21.1
0.61
15
2.23
9.3
254
87

23.6
0.67
14
2.30
9.6
264
90

21.1
0.46
11
2.21
9.2
251
86

22.9
0.48
11
2.26
9.5
259
88

23.6
0.50
11
2.28
9.5
262
89

105

24.5
0.41
10
2.35
9.9
273
95
22.7
0.39
10
2.30
9.6
265
92

25.3
0.43
10
2.37
9.9
276
96

71

59

19.0
0.95
18
2.24
9.5
254
79
17.5
0.91
19
2.19
9.3
247
77

19.6
0.99
18
2.26
9.6
257
80

17.3
0.80
16
2.17
9.2
244
76

18.7
0.83
16
2.22
9.5
252
79

19.3
0.87
15
2.24
9.5
254
79

63

19.6
0.85
17
2.29
9.8
274
85
18.1
0.82
17
2.23
9.5
266
82

20.2
0.89
16
2.30
9.8
277
85

17.9
0.67
14
2.22
9.4
263
81

19.4
0.70
14
2.27
9.7
271
84

20.0
0.73
13
2.28
9.8
274
85

67

21.2
0.64
14
2.35
10.0
289
92
19.6
0.62
14
2.30
9.8
281
90

21.8
0.67
13
2.37
10.1
292
93

19.6
0.47
11
2.28
9.7
278
89

21.2
0.48
10
2.34
10.0
286
91

21.9
0.51
10
2.35
10.0
289
92

115

22.7
0.41
10
2.43
10.4
302
98
21.0
0.40
10
2.37
10.1
293
95

23.4
0.43
9
2.44
10.5
305
99

71

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1324M21A*

33

34

24.1
0.85
21
1.82
7.3
153
68

22.3
0.82
21
1.79
7.1
149
66

25.2
0.96
22
1.85
7.4
156
70

24.5
0.92
23
1.84
7.3
155
69

22.6
0.88
23
1.80
7.1
150
67

MBh
23.6
S/T
0.91
Delta T 22
KW
1.79
AMPS 7.1
HI PR 142
LO PR
64

MBh
21.8
S/T
0.87
Delta T 22
KW
1.75
AMPS 7.0
HI PR 138
LO PR
62

MBh
24.8
S/T
1.00
Delta T 22
KW
1.82
AMPS 7.2
HI PR 145
LO PR
65

MBh
24.0
S/T
0.95
Delta T 23
KW
1.80
AMPS 7.2
HI PR 144
LO PR
65

MBh
22.2
S/T
0.92
Delta T 24
KW
1.77
AMPS 7.0
HI PR 139
LO PR
63

900

788

1013

900

788

1013

63
24.9
0.89
20
1.84
7.3
155
69

59
MBh
24.3
S/T
0.95
Delta T 21
KW
1.80
AMPS 7.2
HI PR 144
LO PR
65

Airflow

65

23.7
0.80
22
1.85
7.3
158
73

25.7
0.83
22
1.89
7.5
163
75

26.4
0.87
21
1.90
7.6
165
76

23.8
0.67
19
1.83
7.3
157
72

25.8
0.69
18
1.87
7.5
162
75

67
26.6
0.72
17
1.89
7.5
163
75

25.3
0.65
19
1.90
7.6
165
78

27.4
0.67
19
1.94
7.8
170
80

28.2
0.70
18
1.95
7.8
172
81

25.5
0.50
15
1.89
7.5
164
77

27.6
0.52
15
1.93
7.7
169
79

71
28.4
0.54
14
1.94
7.8
170
80

21.7
0.95
24
1.88
7.5
156
66

23.5
0.98
24
1.92
7.7
161
69

24.2
1.00
22
1.94
7.7
163
69

21.3
0.90
23
1.87
7.4
155
66

23.1
0.94
22
1.91
7.6
160
68

59
23.8
1.00
22
1.92
7.7
161
69

22.1
0.92
24
1.92
7.6
168
71

23.9
0.95
23
1.96
7.8
174
73

24.7
1.00
22
1.97
7.9
175
74

21.8
0.85
22
1.90
7.6
167
70

23.6
0.88
21
1.95
7.8
172
72

63
24.3
0.92
20
1.96
7.8
174
73

75

23.1
0.83
22
1.97
7.9
178
77

25.1
0.86
22
2.02
8.0
183
80

25.8
0.90
21
2.03
8.1
185
80

23.3
0.69
19
1.96
7.8
176
76

25.2
0.72
18
2.00
8.0
181
79

67
26.0
0.75
18
2.02
8.0
183
80

24.7
0.67
19
2.03
8.1
185
82

26.8
0.69
19
2.07
8.3
191
85

27.6
0.73
18
2.09
8.4
193
86

24.9
0.52
15
2.01
8.0
184
81

26.9
0.54
15
2.06
8.2
189
84

71
27.7
0.56
14
2.07
8.3
191
85

21.2
0.97
24
1.99
8.0
178
69

22.9
1.00
23
2.03
8.2
183
71

23.6
1.00
21
2.05
8.3
185
72

20.8
0.93
23
1.97
8.0
176
68

22.5
0.96
22
2.02
8.2
182
70

59
23.2
1.00
21
2.03
8.2
183
71

21.6
0.94
24
2.02
8.2
191
73

23.4
0.97
23
2.07
8.4
197
76

24.1
1.00
22
2.09
8.5
199
77

21.3
0.87
22
2.01
8.1
190
73

23.0
0.90
21
2.06
8.3
195
75

22.6
0.85
22
2.08
8.4
202
80

24.5
0.88
22
2.13
8.7
208
83

25.2
0.92
21
2.15
8.7
210
84

22.7
0.71
19
2.07
8.4
200
79

24.6
0.73
18
2.11
8.6
206
82

24.1
0.69
19
2.14
8.7
211
85

26.1
0.71
19
2.19
8.9
217
88

26.9
0.75
18
2.21
9.0
220
89

24.3
0.53
15
2.13
8.6
209
85

26.3
0.55
15
2.18
8.9
215
87

20.6
1.00
24
2.08
8.5
203
73

22.4
1.00
23
2.12
8.7
209
75

23.0
1.00
21
2.14
8.8
211
76

20.3
0.96
23
2.06
8.4
201
72

22.0
0.99
22
2.11
8.7
207
74

21.0
0.97
24
2.12
8.7
218
77

22.8
1.00
23
2.17
8.9
225
80

23.5
1.00
21
2.18
9.0
227
80

20.7
0.90
22
2.10
8.6
216
76

22.5
0.93
21
2.15
8.8
223
79

22.0
0.87
22
2.18
8.9
230
84

23.9
0.91
22
2.23
9.2
237
87

24.6
0.95
21
2.25
9.2
240
88

22.2
0.73
19
2.16
8.9
228
83

24.0
0.76
19
2.21
9.1
235
86

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
23.7
25.3 27.1 22.6
23.1
24.7
0.95
0.77 0.58 1.00
1.00
0.79
20
18
14
21
21
18
2.07
2.13 2.19 2.12
2.17
2.23
8.4
8.7
8.9
8.7
8.9
9.2
197
208
217
209
225
237
76
83
88
75
80
87

23.5
0.71
19
2.25
9.2
240
90

25.5
0.74
19
2.30
9.5
248
93

26.2
0.77
18
2.32
9.6
250
93

23.7
0.55
15
2.23
9.2
238
89

25.7
0.57
15
2.28
9.4
245
92

71
26.4
0.59
14
2.30
9.5
248
93

EXPANDED PERFORMANCE DATA

Shaded area is AHRI rating conditions


IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction access fittings.

85

80

IDB*

MODEL: GPH1324M21A

19.6
1.00
23
2.16
9.0
228
76

21.2
1.00
22
2.21
9.2
235
78

21.9
1.00
20
2.22
9.3
237
79

19.3
0.99
22
2.14
8.9
226
75

20.9
1.00
21
2.19
9.1
233
78

59
21.5
1.00
20
2.21
9.2
235
78

20.0
1.00
23
2.20
9.2
245
81

21.7
1.00
22
2.25
9.4
253
83

22.3
1.00
20
2.27
9.5
255
84

19.7
0.93
21
2.18
9.1
243
80

21.3
0.97
21
2.23
9.3
250
83

63
22.0
1.00
20
2.25
9.4
253
83

20.9
0.91
22
2.26
9.5
259
88

22.7
0.94
22
2.32
9.7
267
91

23.4
0.99
21
2.33
9.8
270
92

21.0
0.76
19
2.25
9.4
256
87

22.8
0.79
18
2.30
9.6
264
90

67
23.5
0.82
18
2.32
9.7
267
91

105

22.3
0.74
19
2.33
9.8
270
94

24.2
0.76
19
2.39
10.0
279
97

24.9
0.80
18
2.40
10.1
281
98

22.5
0.57
15
2.31
9.7
267
93

24.4
0.59
15
2.37
9.9
276
96

71
25.1
0.62
14
2.39
10.0
279
97

18.2
1.00
21
2.22
9.5
252
79

19.7
1.00
20
2.27
9.7
260
81

20.3
1.00
18
2.29
9.8
262
82

17.9
1.00
21
2.21
9.4
249
78

19.3
1.00
20
2.26
9.6
257
80

59
19.9
1.00
18
2.27
9.7
260
81

18.5
1.00
22
2.27
9.7
271
84

20.1
1.00
20
2.32
9.9
279
86

20.7
1.00
19
2.34
10.0
282
87

18.2
0.94
20
2.25
9.6
268
83

19.8
0.97
20
2.30
9.8
277
85

63
20.4
1.00
18
2.32
9.9
279
86

19.4
0.91
21
2.33
10.0
286
91

21.0
0.95
20
2.39
10.2
295
94

21.6
0.99
20
2.41
10.3
298
95

19.5
0.76
17
2.32
9.9
283
90

21.1
0.79
17
2.37
10.1
292
93

67
21.8
0.83
16
2.39
10.2
295
94

115

20.7
0.74
18
2.41
10.3
298
97

22.4
0.77
18
2.46
10.6
308
100

23.1
0.81
17
2.48
10.7
311
101

20.8
0.57
14
2.39
10.2
296
96

22.6
0.59
14
2.44
10.5
305
99

71
23.3
0.62
13
2.46
10.6
308
100

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1324M21A*

28.5
0.74
19
2.13
7.8
144
61

26.3
0.71
19
2.08
7.6
140
60

29.9
0.88
21
2.16
8.0
147
63

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

1050

919

1181

63

67

35.8
0.38
11
2.34
8.8
175
77

71

59

29.2
0.92
21
2.32
8.6
165
66

25.7
0.74
19
2.23
8.3
157
63

27.9
0.77
19
2.29
8.5
162
65

28.7
0.81
18
2.30
8.6
164
66

63

30.1
0.82
19
2.37
8.9
178
70

26.7
0.62
16
2.28
8.5
169
67

28.9
0.64
16
2.33
8.7
174
69

29.8
0.67
16
2.35
8.8
176
70

67

32.5
0.62
16
2.44
9.1
188
77

29.2
0.43
13
2.35
8.7
179
73

31.7
0.44
12
2.40
9.0
184
75

32.6
0.47
12
2.42
9.1
186
76

34.9
0.40
11
2.52
9.5
196
82

71

59

28.5
0.94
21
2.46
9.4
188
69

25.1
0.76
19
2.37
9.0
179
65

27.2
0.79
19
2.42
9.2
184
67

28.0
0.83
18
2.44
9.3
186
68

29.3
0.84
19
2.51
9.6
202
73

26.0
0.63
17
2.42
9.2
192
70

28.2
0.66
16
2.47
9.5
198
72

29.1
0.69
16
2.49
9.5
200
72

28.5
0.44
13
2.49
9.5
203
76

30.9
0.46
12
2.55
9.8
210
78

31.8
0.48
12
2.57
9.9
212
79

33.1
0.39
11
2.66
10.2
221
84
30.6
0.38
11
2.59
10.0
214
82

33.3
0.60
15
2.27
8.5
168
73

29.9
0.41
12
2.19
8.1
159
69

32.4
0.43
12
2.24
8.3
164
71

33.4
0.45
12
2.25
8.4
166
72

MBh
29.0 29.9 32.3 34.7 28.4 29.2 31.6 33.9 27.7
28.5
30.8
S/T
0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.89
0.80
0.61
DT
21
20
16
11
22
20
16
11
22
20
16
75
1050
KW
2.14 2.19 2.25 2.32 2.30 2.35 2.42 2.50 2.44
2.49
2.57
AMPS 7.9
8.1
8.4
8.7
8.6
8.8
9.1
9.4
9.3
9.5
9.9
HI PR 146
157
166
173
164
176
186
194
186
200
212
LO PR
62
66
72
77
66
70
76
81
68
72
79
MBh
26.8 27.6 29.9 32.0 26.2 26.9 29.2 31.3 25.5
26.3
28.5
S/T
0.81 0.73 0.55 0.35 0.84 0.75 0.57 0.37 0.86
0.77
0.58
DT
22
20
16
11
22
20
17
11
22
20
17
919
KW
2.10 2.14 2.20 2.27 2.25 2.30 2.37 2.44 2.39
2.44
2.51
AMPS 7.7
7.9
8.1
8.5
8.3
8.5
8.8
9.1
9.1
9.3
9.6
HI PR 142
152
161
168
159
171
181
188
181
194
205
LO PR
60
64
70
74
64
68
74
79
66
70
77
Shaded area is ACCA (TVA) conditions
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction access fittings.

30.8
0.79
19
2.21
8.2
159
67

27.3
0.60
16
2.12
7.8
151
63

29.6
0.62
16
2.17
8.0
155
65

30.5
0.65
15
2.19
8.1
157
66

75

34.1
0.41
11
2.68
10.3
223
85

1181

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

59

29.4
0.78
18
2.14
7.9
146
62

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

Airflow

65

27.0
0.92
22
2.57
10.0
212
72
24.9
0.89
22
2.50
9.7
206
69

27.8
0.97
21
2.59
10.1
214
72

24.5
0.78
19
2.48
9.6
204
69

26.6
0.81
19
2.55
9.9
210
71

27.3
0.85
18
2.57
10.0
212
72

25.7
0.80
20
2.56
9.9
221
74

27.8
0.83
20
2.62
10.2
228
76

28.6
0.87
19
2.64
10.3
231
77

25.4
0.65
17
2.54
9.8
219
73

27.5
0.68
16
2.60
10.1
226
75

28.3
0.71
16
2.62
10.2
228
76

30.1
0.63
16
2.70
10.6
241
83
27.8
0.60
17
2.64
10.3
234
81

31.0
0.66
16
2.73
10.6
243
84

27.8
0.45
13
2.62
10.2
231
80

30.2
0.47
12
2.68
10.5
239
82

31.1
0.49
12
2.70
10.5
241
83

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67

32.3
0.40
11
2.79
11.0
251
88
29.8
0.39
12
2.72
10.6
244
86

33.3
0.42
11
2.82
11.1
254
89

71

EXPANDED PERFORMANCE DATA

31.8
0.64
16
2.59
10.0
214
80

70

IDB*

MODEL: GPH1330M21AA

59

25.7
0.96
22
2.67
10.6
239
75
23.7
0.92
22
2.61
10.3
232
73

26.4
1.00
21
2.69
10.7
241
76

23.3
0.81
19
2.59
10.2
229
72

25.2
0.84
19
2.65
10.5
236
74

26.0
0.88
18
2.67
10.6
239
75

63

26.4
0.86
20
2.73
10.9
257
80
24.4
0.83
20
2.66
10.6
249
77

27.2
0.90
19
2.75
11.0
259
81

24.1
0.68
16
2.64
10.5
247
77

26.1
0.70
16
2.71
10.8
254
79

26.9
0.74
15
2.73
10.9
257
80

67

28.6
0.65
16
2.82
11.2
271
87
26.4
0.63
17
2.75
10.9
263
84

29.4
0.68
16
2.84
11.3
274
88

26.4
0.47
12
2.72
10.8
260
84

28.6
0.49
12
2.79
11.1
268
86

29.5
0.51
12
2.82
11.2
271
87

105

30.7
0.42
11
2.91
11.7
283
93
28.3
0.40
11
2.84
11.3
274
90

31.6
0.44
11
2.93
11.8
286
94

71

59

23.8
0.97
20
2.76
11.2
264
78
21.9
0.93
20
2.69
10.9
256
75

24.5
1.00
19
2.78
11.4
266
78

21.6
0.82
18
2.67
10.8
253
74

23.4
0.85
17
2.74
11.1
261
77

24.1
0.89
17
2.76
11.2
264
78

63

24.5
0.86
19
2.82
11.5
284
83
22.6
0.83
19
2.75
11.2
275
80

25.2
0.91
18
2.85
11.6
287
83

22.4
0.68
15
2.73
11.1
272
79

24.2
0.71
15
2.80
11.4
281
82

24.9
0.74
14
2.82
11.5
284
82

67

26.5
0.65
15
2.91
11.9
300
90
24.4
0.63
15
2.84
11.6
291
87

27.3
0.69
15
2.94
12.0
303
91

24.5
0.47
12
2.82
11.5
288
86

26.5
0.49
11
2.89
11.8
297
89

27.3
0.52
11
2.91
11.9
300
90

115

28.4
0.42
10
3.01
12.4
313
96
26.2
0.41
11
2.93
12.0
303
93

29.3
0.44
10
3.03
12.5
316
97

71

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1330M21*

35

36

29.5
0.92
24
2.16
8.0
147
63

27.3
0.89
24
2.11
7.8
143
61

31.0
1.00
24
2.19
8.1
150
64

30.1
0.97
25
2.18
8.1
149
63

27.7
0.93
26
2.13
7.8
144
61

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

1050

919

1181

1050

919

1181

59
30.4
0.97
23
2.18
8.1
149
63

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

Airflow

28.3
0.90
25
2.17
8.0
155
65

30.6
0.93
25
2.22
8.3
160
67

31.6
0.98
24
2.24
8.3
162
68

27.9
0.84
23
2.15
8.0
154
65

30.2
0.87
23
2.21
8.2
159
67

63
31.1
0.91
22
2.22
8.3
160
67

65

29.6
0.81
24
2.24
8.3
164
71

32.1
0.84
24
2.29
8.5
169
73

33.1
0.88
23
2.31
8.6
171
74

29.8
0.68
20
2.22
8.2
163
71

32.3
0.70
20
2.27
8.5
168
73

67
33.2
0.74
19
2.29
8.5
169
73

31.6
0.66
21
2.31
8.6
171
76

34.2
0.68
21
2.36
8.9
176
78

35.3
0.72
20
2.38
8.9
178
79

31.8
0.51
16
2.29
8.5
169
75

34.5
0.53
16
2.34
8.8
175
77

71
35.5
0.55
15
2.36
8.9
176
78

27.1
0.97
26
2.28
8.5
162
65

29.4
1.00
26
2.34
8.7
167
67

30.2
1.00
24
2.36
8.8
169
68

26.6
0.92
25
2.27
8.4
160
64

28.9
0.96
24
2.32
8.6
165
66

59
29.7
1.00
23
2.34
8.7
167
67

27.6
0.93
26
2.33
8.7
174
69

29.9
0.97
25
2.39
8.9
180
71

30.8
1.00
24
2.41
9.0
182
72

27.2
0.87
24
2.31
8.6
173
68

29.5
0.90
23
2.37
8.9
178
70

63
30.4
0.94
22
2.39
8.9
180
71

75

28.9
0.84
24
2.40
9.0
184
75

31.3
0.87
24
2.46
9.2
190
78

32.3
0.92
23
2.48
9.3
192
78

29.1
0.70
20
2.39
8.9
182
75

31.5
0.73
20
2.44
9.2
188
77

67
32.4
0.77
19
2.46
9.2
190
78

30.9
0.68
21
2.48
9.3
192
80

33.4
0.71
21
2.54
9.6
198
83

34.4
0.74
20
2.56
9.7
200
84

31.1
0.53
16
2.46
9.2
190
79

33.7
0.55
16
2.52
9.5
196
82

71
34.7
0.57
15
2.54
9.6
198
83

26.5
0.99
26
2.42
9.2
184
67

28.7
1.00
25
2.48
9.5
190
69

29.5
1.00
23
2.50
9.6
192
70

26.0
0.95
25
2.40
9.1
183
67

28.2
0.98
24
2.46
9.4
188
69

59
29.0
1.00
23
2.48
9.5
190
69

27.0
0.96
26
2.47
9.5
198
72

29.2
0.99
25
2.53
9.7
204
74

30.1
1.00
23
2.56
9.8
207
75

26.6
0.89
24
2.45
9.4
196
71

28.8
0.92
23
2.51
9.6
202
73

28.2
0.86
24
2.55
9.8
209
78

30.6
0.90
24
2.61
10.0
216
81

31.5
0.94
23
2.64
10.1
218
82

28.4
0.72
21
2.53
9.7
207
78

30.8
0.75
20
2.59
10.0
214
80

30.1
0.70
21
2.63
10.1
218
83

32.6
0.73
21
2.70
10.4
225
86

33.6
0.76
20
2.72
10.5
227
87

30.3
0.54
16
2.61
10.0
216
83

32.9
0.56
16
2.68
10.3
223
85

25.8
1.00
26
2.55
9.9
210
71

28.0
1.00
24
2.61
10.1
216
73

28.8
1.00
22
2.63
10.2
219
74

25.4
0.98
25
2.52
9.8
208
70

27.5
1.00
24
2.59
10.1
214
72

26.3
0.99
26
2.60
10.1
226
75

28.5
1.00
25
2.66
10.4
233
78

29.4
1.00
23
2.69
10.5
235
78

25.9
0.92
24
2.58
10.0
224
75

28.1
0.95
23
2.64
10.3
231
77

27.6
0.89
25
2.68
10.4
239
82

29.9
0.92
24
2.75
10.7
246
85

30.7
0.97
23
2.77
10.8
248
86

27.7
0.75
21
2.66
10.4
236
81

30.0
0.77
20
2.73
10.7
244
84

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
29.6
31.7 33.9 28.3
28.9
30.9
0.97
0.79 0.59 1.00
1.00
0.81
22
19
15
22
23
20
2.53
2.61 2.70 2.61
2.66
2.75
9.7
10.0 10.4 10.1
10.4
10.7
204
216
225
216
233
246
74
81
86
73
78
85

29.4
0.72
21
2.77
10.8
249
88

31.8
0.75
21
2.84
11.2
257
90

32.8
0.79
20
2.86
11.3
259
91

29.6
0.56
17
2.75
10.7
246
87

32.1
0.58
16
2.82
11.1
254
89

71
33.0
0.61
16
2.84
11.2
257
90

EXPANDED PERFORMANCE DATA

Shaded area is AHRI Rating Conditions


IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction access fittings.

85

80

IDB*

MODEL: GPH1330M21AA

24.5
1.00
25
2.65
10.5
236
74

26.6
1.00
23
2.72
10.8
243
76

27.4
1.00
21
2.74
10.9
246
77

24.1
1.01
24
2.63
10.4
234
73

26.1
1.00
23
2.69
10.7
241
76

59
26.9
1.00
21
2.72
10.8
243
76

25.0
1.00
25
2.71
10.8
254
79

27.1
1.00
24
2.77
11.1
262
81

27.9
1.00
22
2.80
11.2
265
82

24.6
0.95
23
2.68
10.7
252
78

26.7
0.99
23
2.75
11.0
259
81

63
27.5
1.00
21
2.77
11.1
262
81

26.2
0.93
24
2.79
11.1
268
86

28.4
0.96
24
2.86
11.5
277
89

29.2
1.00
23
2.89
11.6
279
90

26.3
0.77
20
2.77
11.0
266
85

28.5
0.80
20
2.84
11.3
274
88

67
29.4
0.84
19
2.86
11.5
277
89

105

27.9
0.75
21
2.88
11.6
280
92

30.3
0.78
21
2.96
11.9
289
95

31.2
0.82
20
2.98
12.0
291
96

28.1
0.58
16
2.86
11.4
277
91

30.5
0.60
16
2.93
11.8
286
94

71
31.4
0.63
15
2.96
11.9
289
95

22.7
1.00
23
2.74
11.1
261
77

24.6
1.00
22
2.81
11.5
269
79

25.3
1.00
20
2.83
11.6
272
80

22.3
1.02
23
2.72
11.0
258
76

24.2
1.00
21
2.78
11.4
266
78

59
24.9
1.00
19
2.81
11.5
269
79

23.1
1.00
23
2.80
11.4
281
82

25.1
1.00
22
2.87
11.7
290
84

25.8
1.00
20
2.89
11.9
292
85

22.8
0.96
22
2.78
11.3
278
81

24.7
0.99
22
2.85
11.6
287
83

63
25.5
1.00
20
2.87
11.7
290
84

24.2
0.93
23
2.89
11.8
297
89

26.3
0.97
22
2.96
12.1
306
92

27.1
1.00
21
2.99
12.3
309
93

24.4
0.78
19
2.86
11.7
294
88

26.4
0.81
19
2.94
12.0
303
91

67
27.2
0.85
18
2.96
12.1
306
92

115

25.9
0.76
20
2.98
12.3
309
95

28.0
0.79
19
3.06
12.6
319
98

28.9
0.82
18
3.09
12.7
322
99

26.0
0.58
15
2.96
12.1
306
94

28.2
0.60
15
3.03
12.5
316
97

71
29.1
0.63
14
3.06
12.6
319
98

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1330M21*

33.9
0.72
19
2.47
10.7
145
63

31.3
0.69
19
2.41
10.5
141
61

35.5
0.86
21
2.50
10.9
148
64

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

1200

1050

1350

63

67

42.4
0.37
11
2.71
11.8
176
79

71

59

34.7
0.89
21
2.69
11.7
166
68

30.5
0.72
19
2.59
11.2
158
64

33.1
0.74
19
2.65
11.5
163
66

34.1
0.78
18
2.67
11.6
165
67

63

35.7
0.79
19
2.74
11.9
179
72

31.6
0.60
17
2.64
11.4
170
69

34.3
0.62
16
2.70
11.7
176
71

35.3
0.65
16
2.72
11.8
177
71

67

38.6
0.60
16
2.83
12.2
189
79

34.7
0.42
13
2.72
11.8
180
75

37.6
0.43
12
2.78
12.1
185
77

38.7
0.45
12
2.80
12.1
187
78

41.4
0.39
11
2.91
12.7
197
84

71

59

33.8
0.91
21
2.85
12.5
189
70

29.8
0.74
19
2.74
12.0
180
67

32.3
0.76
19
2.80
12.3
186
69

33.3
0.80
18
2.83
12.4
187
70

34.8
0.81
19
2.91
12.8
204
75

30.9
0.61
17
2.79
12.3
194
71

33.5
0.64
16
2.86
12.6
200
73

34.5
0.67
16
2.88
12.7
202
74

33.8
0.43
13
2.88
12.7
204
78

36.7
0.44
12
2.95
13.0
211
80

37.8
0.46
12
2.97
13.1
213
81

39.3
0.38
11
3.07
13.5
222
86
36.3
0.36
12
3.00
13.2
215
84

39.5
0.58
16
2.63
11.4
169
75

35.5
0.40
12
2.53
11.0
160
71

38.5
0.42
12
2.59
11.3
165
73

39.6
0.44
12
2.61
11.3
167
74

MBh
34.4 35.5 38.4 41.2 33.6 34.6 37.5 40.2 32.8
33.8
36.6
S/T
0.82 0.73 0.55 0.36 0.85 0.76 0.57 0.37 0.87
0.78
0.59
Delta T 22
20
16
11
22
20
16
11
22
20
16
75
1200
KW
2.49 2.54 2.61 2.69 2.67 2.72 2.80 2.89 2.83
2.88
2.97
AMPS 10.8 11.0 11.3 11.7 11.6 11.8 12.1 12.5 12.4
12.7
13.1
HI PR 147
158
167
174
165
177
187
195
187
202
213
LO PR
64
68
74
79
67
71
78
83
70
74
81
MBh
31.8 32.7 35.4 38.0 31.1 32.0 34.6 37.1 30.3
31.2
33.8
S/T
0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84
0.75
0.57
Delta T 22
20
17
11
22
20
17
12
22
20
17
1050
KW
2.43 2.48 2.55 2.63 2.61 2.66 2.74 2.82 2.76
2.82
2.90
AMPS 10.6 10.8 11.1 11.4 11.3 11.5 11.9 12.2 12.1
12.4
12.8
HI PR 142
153
162
169
160
172
182
189
182
196
207
LO PR
62
66
72
76
65
69
76
81
68
72
79
Shaded area is ACCA (TVA) conditions
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction access fittings.

36.5
0.77
19
2.55
11.1
160
68

32.4
0.58
16
2.46
10.7
152
65

35.1
0.60
16
2.52
10.9
156
67

36.2
0.63
15
2.54
11.0
158
68

75

40.5
0.40
11
3.09
13.6
224
87

1350

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

59

34.9
0.75
18
2.49
10.8
147
64

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

Airflow

65

32.0
0.90
22
2.97
13.2
213
73
29.6
0.86
22
2.90
12.9
207
71

33.0
0.94
21
2.99
13.3
216
74

29.1
0.76
19
2.87
12.8
205
70

31.5
0.79
19
2.94
13.1
211
73

32.5
0.83
18
2.97
13.2
213
73

30.4
0.77
21
2.96
13.1
223
76

33.0
0.80
20
3.03
13.5
230
78

34.0
0.84
19
3.05
13.6
232
79

30.1
0.63
17
2.93
13.0
221
75

32.7
0.66
16
3.01
13.4
227
77

33.6
0.69
16
3.03
13.5
230
78

35.7
0.61
17
3.12
13.9
243
85
33.0
0.58
17
3.05
13.5
235
83

36.8
0.64
16
3.15
14.0
245
86

33.0
0.44
13
3.03
13.4
233
82

35.8
0.46
12
3.10
13.8
240
84

36.9
0.48
12
3.12
13.9
243
85

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67

38.3
0.39
11
3.22
14.4
253
91
35.4
0.38
12
3.15
14.0
245
88

39.5
0.41
11
3.25
14.5
256
92

71

EXPANDED PERFORMANCE DATA

37.7
0.62
16
3.00
13.2
215
82

70

IDB*

MODEL: GPH1336M21A

59

30.4
0.93
22
3.09
14.0
240
77
28.1
0.90
22
3.01
13.6
233
75

31.4
0.97
21
3.11
14.1
243
78

27.6
0.79
19
2.99
13.5
231
74

29.9
0.82
19
3.06
13.8
238
76

30.8
0.86
18
3.09
13.9
240
77

63

31.3
0.83
20
3.15
14.3
258
82
28.9
0.80
20
3.08
13.9
251
79

32.3
0.87
19
3.18
14.4
261
83

28.6
0.66
17
3.05
13.8
248
78

31.0
0.68
16
3.13
14.1
256
81

32.0
0.72
16
3.15
14.3
258
82

67

33.9
0.63
16
3.25
14.7
273
89
31.3
0.61
17
3.17
14.3
265
87

34.9
0.66
16
3.28
14.8
276
90

31.4
0.46
13
3.15
14.2
262
86

34.0
0.47
12
3.23
14.6
270
88

35.0
0.50
12
3.25
14.7
273
89

105

36.4
0.40
11
3.36
15.2
285
95
33.6
0.39
11
3.28
14.8
276
92

37.5
0.42
11
3.39
15.3
287
96

71

59

28.2
0.94
20
3.19
14.7
265
79
26.0
0.90
21
3.11
14.3
257
77

29.0
0.98
19
3.22
14.8
268
80

25.6
0.80
18
3.09
14.2
255
76

27.7
0.82
18
3.16
14.6
263
79

28.6
0.86
17
3.19
14.7
265
79

63

29.0
0.84
19
3.26
15.0
286
85
26.8
0.81
19
3.18
14.6
277
82

29.9
0.88
18
3.28
15.1
288
85

26.5
0.66
15
3.15
14.5
274
81

28.7
0.69
15
3.23
14.9
283
84

29.6
0.72
15
3.26
15.0
285
85

67

31.4
0.63
15
3.36
15.5
301
92
29.0
0.61
16
3.28
15.1
292
90

32.4
0.67
15
3.39
15.6
305
93

29.1
0.46
12
3.25
15.0
289
89

31.5
0.48
12
3.33
15.3
298
91

32.4
0.50
11
3.36
15.5
301
92

115

33.7
0.41
11
3.47
16.0
314
98
31.1
0.39
11
3.39
15.6
305
95

34.7
0.43
10
3.50
16.2
318
99

71

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1336M21*

37

38

35.1
0.90
24
2.50
10.9
148
64

32.4
0.86
24
2.45
10.6
144
62

36.7
0.98
25
2.54
11.1
151
65

35.7
0.94
26
2.52
11.0
150
65

32.9
0.91
26
2.47
10.7
145
63

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

1200

1050

1350

1200

1050

1350

59
36.1
0.94
23
2.52
11.0
150
65

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

Airflow

33.6
0.87
26
2.52
10.9
156
67

36.4
0.91
25
2.57
11.2
161
69

37.4
0.95
24
2.59
11.3
163
70

33.1
0.81
23
2.50
10.9
155
66

35.8
0.84
23
2.55
11.1
160
68

63
36.9
0.88
22
2.57
11.2
161
69

65

35.1
0.79
24
2.59
11.3
165
73

38.1
0.82
24
2.65
11.5
170
75

39.2
0.86
23
2.67
11.6
172
76

35.3
0.66
20
2.57
11.2
164
72

38.3
0.68
20
2.63
11.4
169
75

67
39.4
0.72
19
2.65
11.5
170
75

37.5
0.64
21
2.67
11.6
172
78

40.6
0.66
21
2.73
11.9
178
80

41.8
0.70
20
2.75
12.0
179
81

37.8
0.49
16
2.65
11.5
171
77

40.9
0.51
16
2.71
11.8
176
79

71
42.1
0.54
15
2.73
11.9
178
80

32.2
0.94
26
2.65
11.5
163
66

34.8
0.97
26
2.71
11.8
168
69

35.9
1.00
24
2.73
11.8
170
69

31.6
0.90
25
2.63
11.4
161
66

34.2
0.93
24
2.69
11.7
166
68

59
35.3
1.00
24
2.71
11.8
168
69

32.8
0.91
26
2.70
11.7
175
71

35.5
0.94
26
2.76
12.0
181
73

36.6
0.98
25
2.78
12.1
183
74

32.3
0.84
24
2.68
11.6
174
70

35.0
0.87
23
2.74
11.9
179
72

63
36.0
0.91
22
2.76
12.0
181
73

75

34.3
0.82
25
2.78
12.0
185
77

37.2
0.85
24
2.85
12.3
191
80

38.3
0.89
23
2.87
12.4
193
80

34.5
0.68
21
2.76
12.0
183
76

37.4
0.71
20
2.83
12.2
189
79

67
38.5
0.74
19
2.85
12.3
191
80

36.6
0.66
21
2.87
12.4
193
82

39.7
0.69
21
2.94
12.8
199
85

40.9
0.72
20
2.96
12.9
201
86

36.9
0.51
16
2.85
12.3
191
81

40.0
0.53
16
2.91
12.7
197
84

71
41.2
0.56
16
2.94
12.8
199
85

31.4
0.96
26
2.80
12.3
185
69

34.0
1.00
26
2.87
12.6
191
71

35.0
1.00
24
2.89
12.7
193
72

30.9
0.92
25
2.78
12.2
184
68

33.4
0.95
24
2.85
12.5
189
70

59
34.4
1.00
23
2.87
12.6
191
71

32.0
0.93
26
2.86
12.6
200
73

34.7
0.96
26
2.93
12.9
206
76

35.7
1.00
24
2.95
13.0
208
77

31.5
0.86
24
2.84
12.5
198
73

34.2
0.89
23
2.91
12.8
204
75

33.5
0.84
25
2.95
13.0
211
80

36.3
0.87
24
3.02
13.3
217
83

37.4
0.91
23
3.05
13.4
219
84

33.7
0.70
21
2.93
12.9
209
79

36.5
0.73
20
3.00
13.2
215
82

35.8
0.68
21
3.04
13.4
220
85

38.7
0.71
21
3.12
13.7
227
88

39.9
0.74
20
3.14
13.9
229
89

36.0
0.52
17
3.02
13.3
218
85

39.0
0.54
16
3.09
13.6
224
87

30.6
0.99
27
2.94
13.1
211
73

33.2
1.00
25
3.01
13.4
218
75

34.2
1.00
23
3.04
13.5
220
76

30.1
0.95
25
2.92
13.0
209
72

32.6
0.98
25
2.99
13.3
216
74

31.2
0.96
26
3.00
13.4
227
77

33.8
0.99
26
3.08
13.7
234
80

34.8
1.00
24
3.10
13.8
237
80

30.8
0.89
24
2.98
13.3
225
76

33.3
0.92
24
3.05
13.6
232
79

32.7
0.86
25
3.10
13.8
240
84

35.4
0.90
24
3.18
14.1
247
87

36.5
0.94
23
3.20
14.2
250
88

32.9
0.72
21
3.07
13.7
238
83

35.6
0.75
20
3.15
14.0
245
86

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
35.2
37.6 40.2 33.6
34.3
36.7
0.94
0.76 0.57 1.00
0.97
0.79
22
20
16
23
23
20
2.93
3.02 3.12 3.01
3.08
3.18
12.9
13.3 13.7 13.4
13.7
14.1
206
217
227
218
234
247
76
83
88
75
80
87

34.9
0.70
21
3.20
14.2
250
90

37.8
0.73
21
3.28
14.6
258
93

38.9
0.76
20
3.30
14.7
261
93

35.1
0.54
17
3.17
14.1
248
89

38.1
0.56
16
3.25
14.5
256
92

71
39.2
0.59
16
3.28
14.6
258
93

EXPANDED PERFORMANCE DATA

Shaded area is AHRI Rating Conditions


IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction access fittings.

85

80

IDB*

MODEL: GPH1336M21A

29.1
1.00
25
3.06
13.8
238
76

31.5
1.00
24
3.14
14.2
245
78

32.5
1.00
22
3.16
14.3
247
79

28.6
0.98
25
3.04
13.7
235
75

31.0
1.00
24
3.11
14.1
243
78

59
31.9
1.00
22
3.14
14.2
245
78

29.7
0.99
26
3.13
14.1
256
81

32.1
1.00
25
3.20
14.5
264
83

33.1
1.00
23
3.23
14.6
266
84

29.2
0.92
24
3.10
14.0
253
80

31.7
0.96
23
3.18
14.4
261
83

63
32.6
1.00
22
3.20
14.5
264
83

31.1
0.90
24
3.23
14.6
270
88

33.7
0.93
24
3.31
14.9
278
91

34.7
0.98
23
3.33
15.1
281
92

31.2
0.75
21
3.20
14.4
267
87

33.8
0.78
20
3.28
14.8
276
90

67
34.8
0.82
19
3.31
14.9
278
91

105

33.1
0.73
21
3.33
15.1
282
94

35.9
0.76
21
3.41
15.5
290
97

37.0
0.79
20
3.44
15.6
293
98

33.4
0.56
16
3.30
14.9
279
93

36.2
0.58
16
3.39
15.3
287
96

71
37.2
0.61
15
3.41
15.5
290
97

26.9
1.00
24
3.16
14.6
263
79

29.2
1.00
22
3.24
14.9
271
81

30.1
1.00
20
3.27
15.1
273
82

26.5
0.99
23
3.14
14.4
260
78

28.7
1.00
22
3.22
14.8
268
80

59
29.6
1.00
20
3.24
14.9
271
81

27.5
1.00
24
3.23
14.9
283
84

29.8
1.00
23
3.31
15.3
291
86

30.7
1.00
21
3.34
15.4
294
87

27.1
0.93
22
3.21
14.8
280
83

29.3
0.96
22
3.29
15.1
288
85

63
30.2
1.00
21
3.31
15.3
291
86

28.8
0.91
23
3.33
15.3
298
91

31.2
0.94
22
3.42
15.7
308
94

32.1
0.98
22
3.45
15.9
311
95

28.9
0.76
19
3.31
15.2
295
90

31.3
0.78
19
3.39
15.6
305
93

67
32.3
0.82
18
3.42
15.7
308
94

115

30.7
0.73
20
3.44
15.9
311
97

33.3
0.76
19
3.53
16.3
321
100

34.3
0.80
19
3.56
16.4
324
101

30.9
0.57
15
3.41
15.7
308
96

33.5
0.59
15
3.50
16.2
318
99

71
34.5
0.62
14
3.53
16.3
321
100

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1336M21*

45.7
0.73
17
3.27
16.2
148
64

42.1
0.70
18
3.20
15.8
144
62

47.8
0.87
19
3.32
16.4
151
65

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

1750

1531

1969

63

67

57.2
0.38
10
3.59
17.6
179
80

71

59

46.7
0.90
20
3.56
17.4
170
69

41.2
0.73
18
3.43
16.8
161
65

44.6
0.75
18
3.51
17.1
166
67

45.9
0.79
17
3.53
17.3
168
68

63

48.1
0.80
18
3.63
17.7
183
73

42.7
0.61
16
3.50
17.1
174
69

46.2
0.63
15
3.58
17.5
179
72

47.6
0.66
15
3.61
17.6
181
72

67

52.1
0.61
15
3.74
18.2
193
80

46.8
0.42
12
3.60
17.5
183
76

50.7
0.44
12
3.69
17.9
189
78

52.2
0.46
11
3.72
18.0
191
79

55.9
0.39
10
3.86
18.7
201
85

71

59

45.6
0.92
20
3.77
18.6
193
71

40.2
0.75
18
3.63
17.9
184
68

43.5
0.77
18
3.72
18.3
189
70

44.8
0.81
17
3.74
18.4
191
71

47.0
0.82
18
3.85
18.9
208
76

41.7
0.62
16
3.70
18.2
198
72

45.1
0.65
15
3.79
18.6
204
74

46.5
0.68
15
3.82
18.8
206
75

45.6
0.43
12
3.82
18.7
209
79

49.4
0.45
12
3.91
19.1
215
81

50.9
0.47
11
3.94
19.3
217
82

53.0
0.38
11
4.06
19.9
227
87
48.9
0.37
11
3.97
19.4
220
85

53.3
0.59
15
3.49
17.1
172
75

47.9
0.41
12
3.36
16.5
164
72

51.9
0.42
11
3.44
16.9
169
74

53.4
0.44
11
3.46
17.0
170
75

MBh
46.4 47.8 51.8 55.5 45.4 46.7 50.6 54.3 44.3
45.6
49.3
S/T
0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88
0.79
0.60
Delta T 20
19
15
11
20
19
15
11
20
19
15
75
1750
KW
3.30 3.36 3.46 3.57 3.54 3.61 3.72 3.83 3.74
3.82
3.94
AMPS 16.3 16.6 17.0 17.5 17.3 17.6 18.0 18.6 18.4
18.8
19.3
HI PR 150
161
170
178
168
181
191
199
191
206
217
LO PR
64
68
75
80
68
72
79
84
71
75
82
MBh
42.9 44.1 47.8 51.3 41.9 43.1 46.7 50.1 40.9
42.1
45.5
S/T
0.80 0.71 0.54 0.35 0.83 0.74 0.56 0.36 0.85
0.76
0.57
Delta T 21
19
15
11
21
19
16
11
21
19
16
1531
KW
3.22 3.29 3.38 3.49 3.45 3.52 3.63 3.74 3.66
3.73
3.85
AMPS 15.9 16.2 16.6 17.1 16.9 17.2 17.7 18.2 18.0
18.4
18.9
HI PR 145
156
165
172
163
176
185
193
185
200
211
LO PR
62
66
72
77
66
70
77
82
68
73
80
Shaded area is ACCA (TVA) conditions
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction access fittings.

49.2
0.78
18
3.39
16.7
163
69

43.7
0.59
15
3.26
16.1
155
66

47.3
0.61
15
3.34
16.4
160
68

48.8
0.64
15
3.36
16.6
161
68

75

54.6
0.40
10
4.10
20.0
229
88

1969

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

59

47.0
0.76
17
3.30
16.3
150
64

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

Airflow

65

43.2
0.91
21
3.93
19.4
218
74
39.9
0.88
21
3.84
19.0
211
72

44.5
0.95
20
3.96
19.6
220
75

39.2
0.77
18
3.81
18.9
209
71

42.5
0.80
18
3.90
19.3
216
73

43.8
0.84
17
3.93
19.4
218
74

41.1
0.78
19
3.92
19.4
227
77

44.5
0.81
19
4.01
19.8
234
79

45.8
0.85
18
4.04
20.0
237
80

40.6
0.64
16
3.89
19.2
225
76

44.0
0.67
15
3.98
19.7
232
78

45.4
0.70
15
4.01
19.8
234
79

48.1
0.61
16
4.14
20.3
248
86
44.4
0.59
16
4.04
19.9
240
84

49.6
0.64
15
4.17
20.5
250
87

44.5
0.45
12
4.01
19.7
238
83

48.2
0.46
12
4.10
20.2
245
85

49.7
0.48
11
4.14
20.3
247
86

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67

51.7
0.40
11
4.27
21.0
258
92
47.7
0.38
11
4.17
20.5
250
89

53.2
0.41
10
4.30
21.1
261
93

71

EXPANDED PERFORMANCE DATA

50.8
0.62
15
3.97
19.4
219
83

70

IDB*

MODEL: GPH1348M21A

59

41.0
0.94
20
4.09
20.4
245
78
37.9
0.91
21
3.99
20.0
238
75

42.3
0.99
20
4.12
20.6
247
78

37.2
0.80
18
3.96
19.8
235
75

40.4
0.83
18
4.05
20.3
243
77

41.6
0.87
17
4.09
20.4
245
78

63

42.3
0.84
19
4.17
20.8
264
83
39.0
0.81
19
4.07
20.4
256
80

43.5
0.88
18
4.21
21.0
266
84

38.6
0.67
15
4.04
20.2
253
79

41.8
0.69
15
4.14
20.7
261
82

43.1
0.73
15
4.17
20.8
264
83

67

45.7
0.64
15
4.30
21.4
278
90
42.2
0.62
16
4.20
20.9
270
88

47.1
0.67
15
4.34
21.6
281
91

42.3
0.46
12
4.17
20.8
267
87

45.8
0.48
12
4.27
21.2
276
89

47.2
0.50
11
4.30
21.4
278
90

105

49.1
0.41
11
4.44
22.1
290
96
45.3
0.40
11
4.33
21.6
282
93

50.6
0.43
10
4.48
22.3
293
97

71

59

38.0
0.95
19
4.22
21.4
271
80
35.1
0.92
19
4.12
20.9
263
78

39.2
1.00
18
4.26
21.6
273
81

34.5
0.81
17
4.09
20.8
260
77

37.4
0.84
16
4.19
21.3
268
80

38.5
0.88
16
4.22
21.4
271
80

63

39.1
0.85
17
4.31
21.9
291
86
36.1
0.82
18
4.21
21.4
283
83

40.3
0.89
17
4.35
22.0
294
86

35.8
0.67
14
4.17
21.2
280
82

38.7
0.70
14
4.28
21.7
288
85

39.9
0.73
14
4.31
21.9
291
86

67

42.4
0.64
14
4.45
22.5
308
93
39.1
0.62
15
4.34
21.9
298
91

43.6
0.67
14
4.49
22.6
311
94

39.2
0.47
11
4.31
21.8
295
90

42.5
0.48
11
4.41
22.3
305
92

43.7
0.51
10
4.45
22.5
308
93

115

45.5
0.41
10
4.59
23.2
321
99
42.0
0.40
10
4.48
22.6
311
96

46.8
0.43
9
4.63
23.4
324
100

71

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1348M21*

39

40

47.3
0.91
23
3.32
16.4
151
65

43.6
0.88
23
3.25
16.0
147
63

49.5
1.00
23
3.37
16.6
154
66

48.1
0.95
24
3.35
16.5
153
66

44.4
0.92
24
3.27
16.1
148
64

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

1750

1531

1969

1750

1531

1969

59
48.7
0.95
22
3.35
16.5
153
66

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

Airflow

45.2
0.89
24
3.34
16.4
160
68

49.0
0.92
24
3.41
16.8
165
70

50.5
0.96
23
3.44
16.9
166
70

44.6
0.82
22
3.31
16.3
158
67

48.3
0.85
22
3.39
16.7
163
69

63
49.7
0.89
21
3.41
16.8
165
70

65

47.4
0.80
23
3.44
16.9
169
74

51.3
0.83
22
3.52
17.2
174
76

52.9
0.87
21
3.54
17.3
175
77

47.6
0.67
19
3.41
16.7
167
73

51.6
0.69
19
3.49
17.1
172
75

67
53.1
0.73
18
3.52
17.2
174
76

50.6
0.65
20
3.54
17.3
176
79

54.8
0.67
19
3.62
17.7
181
81

56.4
0.70
19
3.65
17.8
183
82

50.9
0.50
15
3.51
17.2
174
78

55.2
0.52
15
3.59
17.6
179
80

71
56.8
0.54
14
3.62
17.7
181
81

43.4
0.95
25
3.51
17.1
166
67

47.0
0.99
24
3.59
17.5
172
69

48.4
1.00
23
3.62
17.6
173
70

42.6
0.91
23
3.48
17.0
165
67

46.2
0.94
23
3.56
17.4
170
69

59
47.6
1.00
22
3.59
17.5
172
69

44.2
0.92
24
3.58
17.5
179
72

47.9
0.95
24
3.66
17.8
185
74

49.3
1.00
23
3.69
18.0
186
74

43.5
0.85
22
3.55
17.3
177
71

47.2
0.88
22
3.64
17.7
183
73

63
48.6
0.93
21
3.66
17.8
185
74

75

46.3
0.83
23
3.69
17.9
189
78

50.1
0.86
23
3.77
18.3
195
80

51.7
0.90
22
3.80
18.4
197
81

46.5
0.69
19
3.66
17.8
187
77

50.4
0.72
19
3.75
18.2
193
80

67
51.9
0.75
18
3.77
18.3
195
80

49.4
0.67
20
3.80
18.4
197
83

53.5
0.70
20
3.89
18.8
203
86

55.1
0.73
19
3.92
19.0
205
87

49.7
0.52
15
3.77
18.3
195
82

53.9
0.54
15
3.86
18.7
201
85

71
55.5
0.56
15
3.89
18.8
203
86

42.3
0.98
25
3.71
18.3
189
70

45.9
1.00
24
3.80
18.7
195
72

47.2
1.00
22
3.83
18.8
197
73

41.6
0.93
23
3.69
18.2
187
69

45.1
0.96
23
3.77
18.6
193
71

59
46.4
1.00
22
3.80
18.7
195
72

43.1
0.94
24
3.79
18.6
204
74

46.7
0.98
24
3.88
19.1
210
77

48.1
1.00
22
3.91
19.2
212
77

42.5
0.87
22
3.76
18.5
202
74

46.1
0.90
22
3.85
18.9
208
76

45.2
0.85
23
3.91
19.1
215
81

49.0
0.88
23
4.00
19.6
222
84

50.4
0.92
22
4.03
19.7
224
84

45.4
0.71
19
3.88
19.0
213
80

49.2
0.74
19
3.97
19.4
220
83

48.2
0.69
20
4.03
19.7
224
86

52.2
0.71
20
4.13
20.2
231
89

53.8
0.75
19
4.16
20.3
234
90

48.5
0.53
15
4.00
19.6
222
86

52.6
0.55
15
4.10
20.0
229
88

41.3
1.00
25
3.90
19.3
216
73

44.7
1.00
24
3.99
19.7
222
76

46.1
1.00
22
4.02
19.9
224
76

40.6
0.96
23
3.87
19.1
213
73

44.0
1.00
23
3.96
19.6
220
75

42.1
0.97
25
3.98
19.7
232
78

45.6
1.00
24
4.08
20.1
239
80

47.0
1.00
22
4.11
20.3
242
81

41.5
0.90
22
3.95
19.5
230
77

44.9
0.93
22
4.04
20.0
237
80

44.1
0.88
23
4.10
20.2
245
85

47.8
0.91
23
4.20
20.7
253
88

49.2
0.95
22
4.24
20.8
255
89

44.3
0.73
19
4.07
20.0
243
84

48.0
0.76
19
4.17
20.5
250
87

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
47.4
50.7 54.2 45.3
46.3
49.4
0.95
0.77 0.58 1.00
1.00
0.80
21
18
15
21
22
18
3.88
4.00 4.13 3.99
4.08
4.20
19.1
19.6 20.2 19.7
20.1
20.7
210
222
231
222
239
253
77
84
89
76
80
88

47.0
0.71
20
4.23
20.8
255
91

51.0
0.74
20
4.34
21.3
263
94

52.5
0.77
19
4.37
21.5
266
95

47.4
0.55
16
4.20
20.7
253
90

51.3
0.57
15
4.30
21.1
261
93

71
52.9
0.60
15
4.34
21.3
263
94

EXPANDED PERFORMANCE DATA

Shaded area is AHRI Rating Conditions


IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction access fittings.

85

80

IDB*

MODEL: GPH1348M21A

39.2
1.00
24
4.05
20.3
242
77

42.5
1.00
22
4.15
20.7
250
79

43.8
1.00
20
4.19
20.9
252
80

38.6
1.00
23
4.02
20.1
240
76

41.8
1.00
22
4.12
20.6
248
79

59
43.0
1.00
20
4.15
20.7
250
79

40.0
1.00
24
4.14
20.7
261
82

43.3
1.00
23
4.24
21.2
269
84

44.6
1.00
21
4.27
21.3
272
85

39.4
0.93
22
4.11
20.5
258
81

42.7
0.97
22
4.21
21.0
266
84

63
44.0
1.00
21
4.24
21.2
269
84

41.9
0.91
23
4.27
21.2
276
89

45.4
0.94
22
4.37
21.7
284
92

46.7
0.99
22
4.41
21.9
287
93

42.1
0.76
19
4.23
21.1
273
88

45.6
0.79
19
4.34
21.6
281
91

67
47.0
0.83
18
4.37
21.7
284
92

105

44.7
0.74
20
4.41
21.9
287
95

48.4
0.77
19
4.52
22.4
296
98

49.9
0.80
19
4.55
22.6
299
99

45.0
0.57
15
4.37
21.7
285
94

48.7
0.59
15
4.48
22.3
293
97

71
50.2
0.62
14
4.52
22.4
296
98

36.3
1.00
22
4.19
21.3
268
80

39.4
1.00
21
4.29
21.8
276
82

40.5
1.00
19
4.32
21.9
279
83

35.7
1.00
22
4.15
21.1
265
79

38.7
1.00
20
4.26
21.6
273
81

59
39.9
1.00
19
4.29
21.8
276
82

37.0
1.00
22
4.28
21.7
288
85

40.1
1.00
21
4.38
22.2
297
87

41.3
1.00
19
4.42
22.4
300
88

36.5
0.94
21
4.24
21.5
285
84

39.5
0.98
20
4.35
22.0
294
86

63
40.7
1.00
19
4.38
22.2
297
87

38.8
0.92
21
4.41
22.3
304
92

42.0
0.95
21
4.52
22.8
314
95

43.3
1.00
20
4.56
23.0
317
96

39.0
0.77
18
4.38
22.1
301
91

42.2
0.80
18
4.49
22.6
311
94

67
43.5
0.83
17
4.52
22.8
314
95

115

41.4
0.74
18
4.55
23.0
318
98

44.8
0.77
18
4.67
23.5
327
101

46.2
0.81
17
4.71
23.7
331
102

41.7
0.57
14
4.52
22.8
314
97

45.2
0.59
14
4.63
23.4
324
100

71
46.5
0.62
14
4.67
23.5
327
101

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1348M21*

54.2
0.72
19
4.28
18.2
154
61

50.1
0.69
20
4.18
17.8
150
60

56.8
0.86
21
4.34
18.5
157
63

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

1850

1619

2081

63

67

67.9
0.37
11
4.71
20.0
187
78

71

59

55.5
0.89
22
4.67
19.8
177
66

48.9
0.72
20
4.49
19.0
168
63

53.0
0.74
20
4.59
19.5
173
65

54.6
0.78
19
4.63
19.6
175
66

63

57.1
0.79
20
4.76
20.2
190
70

50.7
0.60
17
4.58
19.4
181
67

54.9
0.62
17
4.69
19.9
186
69

56.5
0.65
16
4.72
20.0
188
70

67

61.8
0.60
16
4.91
20.8
201
77

55.5
0.42
13
4.72
19.9
191
73

60.1
0.43
13
4.83
20.4
197
75

62.0
0.45
12
4.87
20.6
199
76

66.4
0.39
11
5.07
21.4
209
82

71

59

54.2
0.91
22
4.95
21.2
201
69

47.7
0.74
20
4.76
20.4
191
65

51.7
0.76
20
4.87
20.9
197
67

53.3
0.80
19
4.91
21.1
199
68

55.8
0.81
20
5.05
21.7
216
73

49.5
0.61
17
4.86
20.8
206
70

53.6
0.64
17
4.97
21.4
212
72

55.2
0.67
16
5.01
21.5
214
73

54.2
0.43
13
5.01
21.4
217
76

58.7
0.44
13
5.13
22.0
224
78

60.5
0.46
12
5.17
22.2
226
79

62.9
0.38
12
5.34
22.9
236
84
58.1
0.36
12
5.21
22.3
229
82

63.3
0.58
16
4.57
19.4
179
73

56.8
0.40
13
4.39
18.6
170
69

61.6
0.42
13
4.50
19.1
175
71

63.4
0.44
12
4.53
19.2
177
72

MBh
55.1 56.8 61.5 66.0 53.9 55.5 60.0 64.4 52.6
54.1
58.6
S/T
0.82 0.73 0.55 0.36 0.85 0.76 0.57 0.37 0.87
0.78
0.59
DT
22
21
17
12
23
21
17
12
23
21
17
75
1850
KW
4.31 4.40 4.53 4.67 4.63 4.73 4.87 5.03 4.91
5.01
5.17
AMPS 18.3 18.7 19.2 19.9 19.6 20.0 20.6 21.3 21.1
21.5
22.2
HI PR 156
168
177
185
175
188
199
207
199
214
226
LO PR 62
66
72
77
66
70
76
81
68
73
79
MBh
50.9 52.4 56.7 60.9 49.7 51.2 55.4 59.5 48.5
50.0
54.1
S/T
0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84
0.75
0.57
DT
23
21
17
12
23
21
17
12
23
21
17
1619
KW
4.21 4.30 4.43 4.56 4.52 4.61 4.76 4.91 4.79
4.89
5.05
AMPS 17.9 18.3 18.8 19.4 19.1 19.5 20.1 20.8 20.6
21.0
21.6
HI PR 151
163
172
179
170
183
193
201
193
208
219
LO PR 60
64
70
74
64
68
74
79
66
70
77
Shaded area is ACCA (TVA) conditions
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction access fittings.

58.5
0.77
20
4.43
18.9
169
67

51.9
0.58
17
4.27
18.1
161
63

56.2
0.60
17
4.37
18.6
166
65

57.9
0.63
16
4.40
18.7
168
66

75

64.8
0.40
11
5.38
23.1
238
85

2081

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

59

55.9
0.75
19
4.31
18.3
156
62

MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR

Airflow

65

51.3
0.90
23
5.16
22.3
227
72
47.3
0.86
23
5.03
21.8
220
69

52.8
0.94
22
5.20
22.5
229
72

46.6
0.76
20
4.99
21.6
217
69

50.4
0.79
20
5.12
22.2
224
71

52.0
0.83
19
5.16
22.3
226
72

48.8
0.77
21
5.14
22.3
236
74

52.8
0.80
21
5.27
22.8
244
76

54.4
0.84
20
5.31
23.0
246
77

48.3
0.63
17
5.10
22.1
234
73

52.3
0.66
17
5.23
22.6
241
75

53.9
0.69
16
5.27
22.8
244
76

57.2
0.61
17
5.44
23.5
257
83
52.8
0.58
18
5.30
22.9
250
81

58.9
0.64
17
5.48
23.7
260
84

52.9
0.44
13
5.26
22.7
247
80

57.3
0.46
13
5.39
23.3
255
82

59.0
0.48
12
5.43
23.5
257
83

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67

61.4
0.39
12
5.61
24.3
268
89
56.6
0.38
12
5.47
23.7
260
86

63.2
0.41
11
5.66
24.5
271
89

71

EXPANDED PERFORMANCE DATA

60.4
0.62
16
5.21
22.3
228
80

70

IDB*

MODEL: GPH1360M21A

59

48.7
0.93
23
5.37
23.6
255
75
45.0
0.90
23
5.24
23.0
247
73

50.2
0.97
22
5.41
23.8
257
76

44.2
0.79
20
5.20
22.8
245
72

47.9
0.82
19
5.32
23.4
252
74

49.4
0.86
19
5.37
23.6
255
75

63

50.2
0.83
21
5.48
24.1
274
80
46.3
0.80
21
5.35
23.5
266
77

51.7
0.87
20
5.53
24.3
277
81

45.8
0.66
17
5.31
23.3
263
77

49.7
0.68
17
5.44
23.9
271
79

51.2
0.72
16
5.48
24.1
274
80

67

54.3
0.63
17
5.66
24.9
290
87
50.1
0.61
17
5.52
24.2
281
85

55.9
0.66
16
5.71
25.1
292
88

50.2
0.46
13
5.48
24.0
278
84

54.4
0.47
13
5.61
24.6
287
86

56.1
0.50
12
5.66
24.9
290
87

105

58.3
0.40
12
5.85
25.7
302
93
53.8
0.39
12
5.70
25.1
293
90

60.0
0.42
11
5.89
25.9
305
94

71

59

45.1
0.94
21
5.55
24.9
282
78
41.7
0.90
21
5.41
24.2
273
75

46.5
0.98
20
5.60
25.1
284
78

41.0
0.80
19
5.37
24.0
270
75

44.4
0.82
18
5.50
24.7
279
77

45.7
0.86
17
5.55
24.9
281
78

63

46.5
0.84
19
5.67
25.4
303
83
42.9
0.81
20
5.53
24.8
294
80

47.9
0.88
19
5.72
25.6
306
83

42.5
0.66
16
5.49
24.6
291
79

46.0
0.69
16
5.62
25.2
300
82

47.4
0.72
15
5.67
25.4
303
83

67

50.3
0.63
16
5.85
26.2
320
90
46.4
0.61
16
5.71
25.5
310
87

51.8
0.67
15
5.90
26.4
323
91

46.5
0.46
12
5.66
25.3
307
87

50.4
0.48
12
5.81
26.0
317
89

51.9
0.50
11
5.85
26.2
320
90

115

54.0
0.41
11
6.05
27.1
334
96
49.8
0.39
11
5.90
26.4
324
93

55.6
0.43
11
6.10
27.3
337
97

71

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1360M21A*

41

42

56.1
0.90
25
4.34
18.5
157
63

51.8
0.86
25
4.25
18.1
153
61

58.8
0.98
26
4.41
18.8
161
64

57.1
0.94
27
4.38
18.6
159
63

52.7
0.91
27
4.28
18.2
154
61

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

1850

1619

2081

1850

1619

2081

59
57.8
0.94
24
4.38
18.6
159
63

MBh
S/T
DT
KW
AMPS
HI PR
LO PR

Airflow

53.7
0.87
27
4.36
18.6
166
65

58.2
0.91
26
4.47
19.0
171
67

60.0
0.95
25
4.50
19.2
173
68

52.9
0.81
24
4.33
18.4
164
65

57.4
0.84
24
4.43
18.9
169
67

63
59.1
0.88
23
4.47
19.0
171
67

65

56.3
0.79
25
4.50
19.1
175
71

61.0
0.82
25
4.60
19.5
181
74

62.8
0.86
24
4.64
19.7
182
74

56.6
0.66
21
4.46
18.9
174
71

61.3
0.68
21
4.57
19.4
179
73

67
63.1
0.72
20
4.60
19.5
181
74

60.0
0.64
22
4.63
19.7
183
76

65.0
0.66
21
4.75
20.2
188
78

67.0
0.70
21
4.78
20.3
190
79

60.5
0.49
17
4.60
19.5
181
75

65.5
0.51
17
4.71
20.0
187
78

71
67.5
0.54
16
4.75
20.2
188
78

51.5
0.94
27
4.59
19.4
173
65

55.8
0.97
27
4.70
19.9
178
67

57.5
1.00
25
4.74
20.1
180
68

50.6
0.90
26
4.56
19.3
171
64

54.8
0.93
25
4.67
19.8
177
66

59
56.5
1.00
25
4.70
19.9
178
67

52.5
0.91
27
4.69
19.9
186
69

56.9
0.94
27
4.80
20.3
192
71

58.6
0.98
25
4.84
20.5
194
72

51.7
0.84
25
4.65
19.7
184
68

56.0
0.87
24
4.76
20.2
190
70

63
57.7
0.91
23
4.80
20.3
192
71

75

55.0
0.82
26
4.83
20.4
197
75

59.6
0.85
25
4.95
20.9
203
78

61.3
0.89
24
4.99
21.1
205
78

55.2
0.68
21
4.79
20.3
195
75

59.9
0.71
21
4.91
20.8
201
77

67
61.6
0.74
20
4.95
20.9
203
78

58.6
0.66
22
4.98
21.1
205
80

63.5
0.69
22
5.11
21.6
211
83

65.4
0.72
21
5.15
21.8
214
84

59.1
0.51
17
4.94
20.9
203
79

64.0
0.53
17
5.07
21.4
209
82

71
65.9
0.56
16
5.11
21.6
211
83

50.3
0.96
27
4.87
20.9
197
67

54.5
1.00
27
4.99
21.4
203
70

56.1
1.00
25
5.03
21.6
205
70

49.4
0.92
26
4.83
20.7
195
67

53.5
0.95
25
4.95
21.2
201
69

59
55.1
1.00
24
4.99
21.4
203
70

51.2
0.93
27
4.97
21.3
212
72

55.5
0.96
27
5.09
21.9
218
74

57.2
1.00
25
5.13
22.1
221
75

50.5
0.86
25
4.93
21.2
210
71

54.7
0.89
24
5.05
21.7
216
73

53.7
0.84
26
5.13
22.0
224
78

58.1
0.87
25
5.25
22.5
231
81

59.9
0.91
24
5.30
22.7
233
82

53.9
0.70
21
5.09
21.8
221
78

58.4
0.73
21
5.21
22.3
228
80

57.2
0.68
22
5.29
22.7
233
83

62.0
0.71
22
5.42
23.3
240
86

63.9
0.74
21
5.47
23.5
243
87

57.6
0.52
17
5.25
22.5
231
83

62.5
0.54
17
5.38
23.1
238
85

49.0
0.99
28
5.12
22.2
224
71

53.1
1.00
26
5.24
22.7
231
73

54.7
1.00
24
5.28
22.9
233
74

48.2
0.95
26
5.07
22.0
222
70

52.2
0.98
25
5.20
22.5
229
72

50.0
0.96
27
5.22
22.6
241
75

54.2
0.99
27
5.35
23.2
249
78

55.8
1.00
25
5.40
23.4
251
78

49.2
0.89
25
5.18
22.5
239
75

53.4
0.92
24
5.31
23.0
246
77

52.3
0.86
26
5.39
23.3
255
82

56.7
0.90
25
5.52
23.9
263
85

58.4
0.94
24
5.57
24.1
265
86

52.6
0.72
22
5.35
23.1
252
81

57.0
0.75
21
5.48
23.7
260
84

Outdoor Ambient Temperature


85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
56.3
60.2 64.3 53.8
55.0
58.7
0.94
0.76 0.57 1.00
0.97
0.79
23
20
16
24
23
20
5.09
5.25 5.42 5.24
5.35
5.52
21.9
22.5 23.3 22.7
23.2
23.9
218
231
240
231
249
263
74
81
86
73
78
85

55.8
0.70
22
5.56
24.1
266
88

60.5
0.73
22
5.70
24.7
274
90

62.3
0.76
21
5.75
24.9
277
91

56.2
0.54
17
5.52
23.9
263
87

60.9
0.56
17
5.66
24.5
271
89

71
62.8
0.59
16
5.70
24.7
274
90

EXPANDED PERFORMANCE DATA

Shaded area is AHRI Rating Conditions


IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction access fittings.

85

80

IDB*

MODEL: GPH1360M21A

46.6
1.00
26
5.32
23.4
252
74

50.5
1.00
25
5.46
24.0
260
77

52.0
1.00
23
5.50
24.2
263
77

45.8
0.98
26
5.28
23.2
250
74

49.6
1.00
25
5.41
23.8
257
76

59
51.1
1.00
23
5.46
24.0
260
77

47.5
0.99
27
5.44
23.9
271
79

51.4
1.00
26
5.57
24.5
280
81

53.0
1.00
23
5.62
24.7
283
82

46.8
0.92
25
5.39
23.7
269
78

50.7
0.96
24
5.53
24.3
277
81

63
52.2
1.00
23
5.57
24.5
280
81

49.7
0.90
25
5.61
24.6
287
86

53.9
0.93
25
5.75
25.3
295
89

55.5
0.98
24
5.80
25.5
298
90

50.0
0.75
21
5.57
24.4
284
85

54.2
0.78
21
5.71
25.1
293
88

67
55.8
0.82
20
5.75
25.3
295
89

105

53.1
0.73
22
5.80
25.5
299
92

57.5
0.76
22
5.94
26.1
308
95

59.2
0.79
21
5.99
26.4
311
96

53.4
0.56
17
5.75
25.3
296
91

57.9
0.58
17
5.89
25.9
305
94

71
59.6
0.61
16
5.94
26.1
308
95

43.1
1.00
25
5.50
24.7
279
77

46.7
1.00
23
5.64
25.3
287
79

48.2
1.00
21
5.69
25.5
290
80

42.4
0.99
24
5.46
24.5
276
76

45.9
1.00
23
5.60
25.1
284
78

59
47.3
1.00
21
5.64
25.3
287
79

44.0
1.00
25
5.62
25.2
300
82

47.7
1.00
24
5.76
25.8
309
84

49.1
1.00
22
5.81
26.1
312
85

43.3
0.93
23
5.58
25.0
297
81

46.9
0.96
23
5.72
25.6
306
83

63
48.4
1.00
21
5.76
25.8
309
84

46.1
0.91
24
5.80
26.0
317
89

49.9
0.94
23
5.95
26.6
326
92

51.4
0.98
22
6.00
26.9
330
93

46.3
0.76
20
5.76
25.7
313
88

50.2
0.78
20
5.90
26.4
323
91

67
51.7
0.82
19
5.95
26.6
326
92

115

49.1
0.73
20
5.99
26.9
330
95

53.2
0.76
20
6.15
27.6
340
98

54.8
0.80
19
6.20
27.8
344
99

49.5
0.57
16
5.95
26.6
327
94

53.6
0.59
16
6.10
27.3
337
97

71
55.2
0.62
15
6.15
27.6
340
98

COOLING OPERATION

COOLING PERFORMANCE DATA


GPH1360M21A*

COOLING PERFORMANCE DATA


PERFORMANCE TEST
All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor
air cubic feet per minute (CFM) as listed in the Performance Data Sheets:
If conditions vary from this, results will change as follows:
1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low
and high side pressures and power will not change.
2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will
occur in low and high side pressures and power.
A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown.
A properly operating unit should be within plus or minus 7 PSIG of the head pressure shown.
A properly operating unit should be within plus or minus 3 PSIG of the suction pressure shown.
A properly operating unit should be within plus or minus 3 Amps of the typical value shown.

43

PACKAGE HEAT PUMP SPECIFICATIONS

GPH13[24-36]H21*

EXPANDED PERFORMANCE DATA


MODEL: GPH1324H21*

HEATING OPERATION

Outdoor Ambient Temperature


65
60
55
50
47
45
40
35
30
25
20
17
MBh
30.2
28.6
26.9
25.1
24.0
23.3
21.6
19.9
16.9
15.6
14.4
13.6
DELTA T 32.9
31.1
29.3
27.4
26.1
25.3
23.5
21.7
18.5
17.0
15.7
14.8
KW
2.23
2.18
2.14
2.10
2.07
2.05
2.01
1.96
2.02
1.97
1.93
1.90
AMPS
11.1
10.4
9.8
9.3
9.0
8.9
8.4
8.0
7.8
7.5
7.2
7.0
COP
3.96
3.83
3.68
3.51
3.39
3.32
3.15
2.97
2.45
2.32
2.19
2.09
EER
13.5
13.1
12.6
12.0
11.6
11.3
10.8
10.1
8.4
7.9
7.5
7.2
HI PR
238
228
220
210
205
201
193
186
178
170
163
159
LO PR
78
73
68
62
59
57
52
46
42
37
33
31
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

15
13.1
14.3
1.88
6.9
2.04
7.0
156
30

10
11.8
12.8
1.83
6.7
1.87
6.4
150
25

MODEL: GPH1330H21*

5
10.4
11.3
1.79
6.3
1.70
5.8
145
22

0
9.1
9.9
1.74
6.0
1.53
5.2
139
18

-5
7.8
8.4
1.69
5.6
1.34
4.6
134
16

-10
6.4
6.9
1.65
5.2
1.13
3.9
129
12

HEATING OPERATION

Outdoor Ambient Temperature


65
60
55
50
47
45
40
35
30
25
20
17
MBh
34.4
32.6
30.7
28.7
27.4
26.6
24.7
22.7
19.7
18.2
16.7
15.8
DELTA T 30.4
28.8
27.1
25.3
24.2
23.4
21.7
20.1
17.4
16.0
14.8
13.9
KW
2.70
2.65
2.59
2.54
2.51
2.49
2.44
2.38
2.34
2.28
2.23
2.20
AMPS
13.1
12.2
11.5
10.9
10.6
10.4
9.9
9.5
9.2
8.8
8.5
8.3
COP
3.73
3.60
3.46
3.30
3.19
3.12
2.96
2.79
2.46
2.33
2.19
2.10
EER
12.7
12.3
11.8
11.3
10.9
10.7
10.1
9.5
8.4
8.0
7.5
7.2
HI PR
244
234
225
215
210
206
198
190
182
174
167
163
LO PR
80
74
69
63
60
58
53
47
43
38
33
31
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

15
15.2
13.4
2.18
8.2
2.04
7.0
160
30

10
13.7
12.0
2.12
7.9
1.88
6.4
154
25

MODEL: GPH1336H21*

5
12.1
10.7
2.07
7.5
1.71
5.8
148
22

0
10.6
9.3
2.02
7.1
1.53
5.2
142
18

-5
9.0
7.9
1.97
6.7
1.34
4.6
137
16

-10
7.4
6.5
1.91
6.2
1.13
3.9
132
13

HEATING OPERATION

Outdoor Ambient Temperature


65
60
55
50
47
45
40
35
30
25
20
17
MBh
42.2
40.0
37.6
35.2
33.6
32.6
30.2
27.9
22.4
20.7
19.1
18.0
DELTA T 31.3
29.6
27.9
26.1
24.9
24.1
22.4
20.7
16.6
15.3
14.1
13.3
KW
3.12
3.06
3.00
2.93
2.90
2.87
2.82
2.76
2.66
2.60
2.54
2.51
AMPS
12.2
11.4
10.8
10.3
10.0
9.8
9.4
9.0
8.7
8.4
8.1
8.0
COP
3.97
3.83
3.68
3.51
3.39
3.31
3.14
2.96
2.47
2.33
2.19
2.10
EER
13.6
13.1
12.6
12.0
11.6
11.3
10.7
10.1
8.4
8.0
7.5
7.2
HI PR
238
228
220
210
205
201
193
186
178
170
163
159
LO PR
81
75
70
65
61
59
54
48
43
39
34
32
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

15
17.3
12.8
2.49
7.9
2.04
7.0
156
31

10
15.6
11.5
2.43
7.6
1.88
6.4
150
26

5
13.8
10.2
2.37
7.2
1.70
5.8
145
22

0
12.0
8.9
2.31
6.9
1.52
5.2
139
19

-5
10.3
7.6
2.25
6.5
1.33
4.6
134
16

-10
8.4
6.2
2.19
6.1
1.12
3.8
129
13

PERFORMANCE TEST
All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor
air cubic feet per minute (CFM) as listed in the Performance Data Sheets:
If conditions vary from this, results will change as follows:
1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low
and high side pressures and power will not change.
2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will
occur in low and high side pressures and power.
A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown.
A properly operating unit should be within plus or minus 7 PSIG of the HI PR shown.
A properly operating unit should be within plus or minus 3 PSIG of the LO PR shown.
A properly operating unit should be within plus or minus 3 Amps of the typical value shown.

44

PACKAGE HEAT PUMP SPECIFICATIONS

GPH13[42-60]H21*

EXPANDED PERFORMANCE DATA


MODEL: GPH1342H21*

HEATING OPERATION

Outdoor Ambient Temperature


65
60
55
50
47
45
40
35
30
25
20
17
MBh
47.8
45.2
42.6
39.8
38.0
36.8
34.2
31.5
27.2
25.1
23.1
21.8
DELTA T 30.5
28.9
27.2
25.4
24.3
23.5
21.8
20.1
17.3
16.0
14.7
13.9
KW
3.32
3.26
3.20
3.14
3.10
3.07
3.01
2.95
2.94
2.88
2.82
2.78
AMPS
12.9
12.1
11.5
10.9
10.6
10.4
10.0
9.6
9.3
9.0
8.6
8.5
COP
4.21
4.06
3.89
3.71
3.59
3.51
3.32
3.13
2.70
2.55
2.40
2.29
EER
14.4
13.9
13.3
12.7
12.3
12.0
11.3
10.7
9.2
8.7
8.2
7.8
HI PR
232
223
214
205
200
196
189
181
173
166
159
155
LO PR
80
74
69
63
60
58
53
47
43
38
33
31
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

15
21.0
13.4
2.76
8.4
2.23
7.6
152
30

10
18.8
12.0
2.69
8.1
2.05
7.0
147
25

MODEL: GPH1348H21*

5
16.7
10.7
2.63
7.7
1.86
6.4
141
22

0
14.6
9.3
2.57
7.4
1.66
5.7
135
18

-5
12.4
7.9
2.50
7.0
1.45
5.0
130
16

-10
10.2
6.5
2.44
6.5
1.22
4.2
126
13

HEATING OPERATION

Outdoor Ambient Temperature


65
60
55
50
47
45
40
35
30
25
20
17
MBh
56.6
53.6
50.4
47.1
45.0
43.6
40.5
37.4
28.9
26.7
24.6
23.2
DELTA T 31.7
30.1
28.3
26.4
25.3
24.5
22.7
21.0
16.2
15.0
13.8
13.0
KW
4.27
4.19
4.12
4.04
4.00
3.97
3.90
3.82
3.58
3.51
3.44
3.40
AMPS
21.4
20.0
18.8
17.9
17.3
17.0
16.2
15.5
14.9
14.4
13.8
13.5
COP
3.88
3.74
3.58
3.41
3.29
3.22
3.04
2.86
2.36
2.22
2.09
2.00
EER
13.2
12.8
12.2
11.7
11.3
11.0
10.4
9.8
8.1
7.6
7.1
6.8
HI PR
244
234
225
215
210
206
198
190
182
174
167
163
LO PR
77
71
67
61
58
56
51
46
41
37
32
30
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

15
22.3
12.5
3.37
13.4
1.94
6.6
160
29

10
20.0
11.2
3.30
12.8
1.78
6.1
154
25

MODEL: GPH1360H21*

5
17.8
10.0
3.23
12.1
1.61
5.5
148
21

0
15.5
8.7
3.16
11.5
1.43
4.9
142
18

-5
13.2
7.4
3.09
10.9
1.25
4.3
137
16

-10
10.8
6.1
3.02
10.0
1.05
3.6
132
12

HEATING OPERATION

Outdoor Ambient Temperature


65
60
55
50
47
45
40
35
30
25
20
17
MBh
68.4
64.7
60.9
57.0
54.4
52.7
49.0
45.2
36.6
33.8
31.1
29.4
DELTA T 33.3
31.5
29.7
27.8
26.5
25.7
23.9
22.0
17.9
16.5
15.2
14.3
KW
5.04
4.94
4.84
4.75
4.69
4.65
4.55
4.46
4.35
4.25
4.16
4.10
AMPS
22.1
20.7
19.5
18.6
18.0
17.7
16.9
16.2
15.6
15.1
14.5
14.2
COP
3.97
3.83
3.68
3.51
3.39
3.32
3.15
2.97
2.46
2.33
2.19
2.10
EER
13.6
13.1
12.6
12.0
11.6
11.3
10.8
10.1
8.4
8.0
7.5
7.2
HI PR
238
228
220
210
205
201
193
186
178
170
163
159
LO PR
74
69
65
59
56
54
50
44
40
36
31
29
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

15
28.3
13.8
4.06
14.1
2.04
7.0
156
28

10
25.4
12.4
3.96
13.5
1.88
6.4
150
24

5
22.5
11.0
3.87
12.8
1.70
5.8
145
20

0
19.6
9.6
3.77
12.2
1.52
5.2
139
17

-5
16.8
8.2
3.67
11.6
1.33
4.6
134
15

-10
13.7
6.7
3.58
10.7
1.12
3.8
129
12

PERFORMANCE TEST
All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor
air cubic feet per minute (CFM) as listed in the Performance Data Sheets:
If conditions vary from this, results will change as follows:
1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low
and high side pressures and power will not change.
2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will
occur in low and high side pressures and power.
A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown.
A properly operating unit should be within plus or minus 7 PSIG of the HI PR shown.
A properly operating unit should be within plus or minus 3 PSIG of the LO PR shown.
A properly operating unit should be within plus or minus 3 Amps of the typical value shown.

45

PACKAGE HEAT PUMP SPECIFICATIONS GPH13[24-36]M21A*


EXPANDED PERFORMANCE DATA
MODEL: GPH1324M21A*
MBh
Delta T
KW
AMPS
COP
EER
HI PR
LO PR

HEATING OPERATION

Outdoor Ambient Temperature


65
60
55
50
47
45
40
35
30
25
20
17
27.7
26.2
24.6
23.0
22.0
21.3
19.8
18.3
15.5
14.3
13.1
12.4
28.5
26.9
25.3
23.7
22.6
21.9
20.4
18.8
15.9
14.7
13.5
12.8
2.01
1.98
1.94
1.91
1.89
1.88
1.84
1.81
1.82
1.79
1.75
1.73
10.3
9.6
9.0
8.6
8.3
8.2
7.8
7.4
7.1
6.9
6.6
6.5
4.02
3.87
3.71
3.53
3.41
3.33
3.15
2.96
2.48
2.34
2.19
2.10
13.7
13.2
12.7
12.1
11.6
11.4
10.7
10.1
8.5
8.0
7.5
7.2
232
223
214
205
200
196
189
181
173
166
159
155
78
73
68
62
59
57
52
46
42
37
33
31
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

15
11.9
12.3
1.72
6.4
2.04
7.0
152
30

10
10.7
11.0
1.68
6.1
1.87
6.4
147
25

MODEL: GPH1330M21*
MBh
Delta T
KW
AMPS
COP
EER
HI PR
LO PR

15
15.4
13.6
2.21
7.4
2.04
7.0
171
30

10
13.8
12.2
2.16
7.1
1.88
6.4
164
25

MODEL: GPH1336M21*

MBh
Delta T
KW
AMPS
COP
EER
HI PR
LO PR

60

0
8.3
8.5
1.61
5.5
1.51
5.1
135
18

-5
7.1
7.3
1.57
5.2
1.32
4.5
130
16

-10
5.8
6.0
1.54
4.8
1.10
3.8
126
12

HEATING OPERATION

Outdoor Ambient Temperature


65
60
55
50
47
45
40
35
30
25
20
17
36.7
34.7
32.7
30.6
29.2
28.3
26.3
24.2
19.9
18.4
16.9
16.0
32.4
30.6
28.8
27.0
25.7
25.0
23.2
21.4
17.6
16.2
14.9
14.1
2.87
2.81
2.76
2.70
2.67
2.65
2.59
2.54
2.37
2.31
2.26
2.23
13.0
12.0
11.2
10.6
10.2
10.0
9.4
8.9
8.5
8.1
7.7
7.5
3.74
3.61
3.47
3.31
3.20
3.13
2.97
2.80
2.47
2.33
2.19
2.10
12.8
12.3
11.9
11.3
10.9
10.7
10.1
9.6
8.4
8.0
7.5
7.2
260
250
240
229
224
220
211
203
194
186
178
174
79
73
68
63
59
57
52
47
42
38
33
31
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

65

5
9.5
9.8
1.64
5.8
1.69
5.8
141
22

5
12.3
10.8
2.10
6.6
1.70
5.8
158
22

0
10.7
9.4
2.05
6.2
1.52
5.2
151
18

-5
9.1
8.0
2.00
5.7
1.33
4.6
146
16

-10
7.5
6.6
1.95
5.1
1.12
3.8
141
12

HEATING OPERATION
55

50

47

45

Outdoor Ambient Temperature


40
35
30
25

20

17

43.0
40.7
38.3
35.8
34.2
33.1
30.8
28.4
23.2
21.4
19.7
18.6
33.2
31.4
29.6
27.6
26.4
25.6
23.8
21.9
17.9
16.5
15.2
14.4
3.16
3.10
3.04
2.98
2.95
2.92
2.86
2.80
2.75
2.69
2.63
2.60
15.9
14.8
14.0
13.2
12.8
12.6
11.9
11.4
11.0
10.6
10.1
9.9
3.98
3.84
3.69
3.52
3.40
3.32
3.15
2.97
2.47
2.33
2.19
2.10
13.6
13.1
12.6
12.0
11.6
11.4
10.8
10.1
8.4
8.0
7.5
7.2
244
234
225
215
210
206
198
190
182
174
167
163
77
71
67
61
58
56
51
46
41
37
32
30
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

15

10

-5

-10

17.9
13.8
2.57
9.8
2.04
7.0
160
29

16.1
12.4
2.51
9.4
1.87
6.4
154
25

14.2
11.0
2.45
8.8
1.70
5.8
148
21

12.4
9.6
2.39
8.4
1.52
5.2
142
18

10.6
8.2
2.33
7.9
1.33
4.5
137
16

8.7
6.7
2.27
7.2
1.12
3.8
132
12

PERFORMANCE TEST
All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor
air cubic feet per minute (CFM) as listed in the Performance Data Sheets:
If conditions vary from this, results will change as follows:
1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low
and high side pressures and power will not change.
2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will
occur in low and high side pressures and power.
A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown.
A properly operating unit should be within plus or minus 7 PSIG of the HI PR shown.
A properly operating unit should be within plus or minus 3 PSIG of the LO PR shown.
A properly operating unit should be within plus or minus 3 Amps of the typical value shown.

46

PACKAGE HEAT PUMP SPECIFICATIONS GPH13[48-60]M21A*


EXPANDED PERFORMANCE DATA
MODEL: GPH1348M21*

MBh
Delta T
KW
AMPS
COP
EER
HI PR
LO PR

HEATING OPERATION

Outdoor Ambient Temperature


65
60
55
50
47
45
40
35
30
25
20
17
56.6
53.6
50.4
47.1
45.0
43.6
40.5
37.4
31.2
28.8
26.5
25.0
29.9
28.3
26.7
24.9
23.8
23.1
21.4
19.8
16.5
15.2
14.0
13.2
4.04
3.97
3.89
3.81
3.77
3.74
3.66
3.59
3.53
3.45
3.37
3.33
21.7
20.4
19.3
18.4
17.9
17.6
16.9
16.2
15.7
15.1
14.6
14.3
4.10
3.95
3.79
3.62
3.49
3.41
3.23
3.05
2.59
2.44
2.30
2.20
14.0
13.5
13.0
12.4
11.9
11.7
11.1
10.4
8.8
8.3
7.8
7.5
232
223
214
205
200
196
189
181
173
166
159
155
76
70
66
60
57
55
50
45
41
36
32
30
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

15
24.1
12.7
3.30
14.2
2.13
7.3
152
29

10
21.6
11.4
3.22
13.7
1.96
6.7
147
24

MODEL: GPH1360M21A*
MBh
Delta T
KW
AMPS
COP
EER
HI PR
LO PR

5
19.2
10.1
3.15
13.0
1.78
6.1
141
21

0
16.7
8.8
3.07
12.5
1.59
5.4
135
18

-5
14.3
7.5
3.00
11.8
1.39
4.8
130
15

-10
11.7
6.2
2.92
11.0
1.17
4.0
126
12

HEATING OPERATION

Outdoor Ambient Temperature


65
60
55
50
47
45
40
35
30
25
20
17
69.1
65.5
61.6
57.6
55.0
53.3
49.5
45.7
38.4
35.4
32.6
30.8
34.6
32.8
30.8
28.8
27.5
26.7
24.8
22.8
19.2
17.7
16.3
15.4
5.09
4.99
4.89
4.80
4.74
4.70
4.61
4.51
4.56
4.46
4.36
4.30
26.3
24.5
23.1
21.9
21.2
20.8
19.8
18.9
18.2
17.5
16.8
16.5
3.98
3.84
3.69
3.51
3.40
3.32
3.14
2.96
2.46
2.33
2.19
2.10
13.6
13.1
12.6
12.0
11.6
11.3
10.7
10.1
8.4
7.9
7.5
7.2
244
234
225
215
210
206
198
190
182
174
167
163
73
68
63
58
55
53
49
43
39
35
31
29
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

15
29.7
14.8
4.26
16.3
2.04
7.0
160
28

10
26.6
13.3
4.16
15.6
1.87
6.4
154
23

5
23.6
11.8
4.06
14.7
1.70
5.8
148
20

0
20.6
10.3
3.96
14.0
1.52
5.2
142
17

-5
17.6
8.8
3.86
13.1
1.33
4.5
137
15

-10
14.4
7.2
3.76
12.1
1.12
3.8
132
12

PERFORMANCE TEST
All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor
air cubic feet per minute (CFM) as listed in the Performance Data Sheets:
If conditions vary from this, results will change as follows:
1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low
and high side pressures and power will not change.
2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will
occur in low and high side pressures and power.
A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown.
A properly operating unit should be within plus or minus 7 PSIG of the HI PR shown.
A properly operating unit should be within plus or minus 3 PSIG of the LO PR shown.
A properly operating unit should be within plus or minus 3 Amps of the typical value shown.

47

WIRING DIAGRAMS

GPH13[24-48]H21A
PU
BK

BK

NOTE #4
RD

208

240

PU

PU

BL

BK
BL

EBTDR

K1

NO

K1

COM

RD

24V

BK

T2

L2

T1

L1

RD

BL

NOTE #2
SPEED
UP

2
0
8
2
4
0
/
1
/
6
0

TR

XFMR-R
XFMR-C
C

RD

BL

BK
BK

RD

NC
BK

YL

BK

SEE NOTE #6

RD
RD
RD

YL

M2

M1

GND

PU

BL

OR

DC

OR

C
Y
PU

RD

YL
RD

O
BK

YL

BK

BR
BUSHING

LVDR

WH

W2

RD

RD

R
RD

LVJB
WH

YL
RD
GR
WH

BL

BK
R

HVDR

YL

PLF
6

DF1

DF2

RD

RD

BR

RCCF

SA

Y
R
G
W1
O
W2
C

OR
BR
BL

DFT

RD
PU

RD

RD
RD

(TRANS240V)

RD RD

BK

PU

(M1) RD

BK

LOW

BL

PU
(COM)BK

BK
BR

HIGH

CONTROL
BOX

YL
S

C R

EM
BR

BR

DFT

3 SPEED

LPS

RD

EM
BR

BKBK

T
H
E
R
M
O
S
T
A
T

BK

PU

(IF USED)
SEE NOTE #5

PU

++

BR
PU

2 SPEED
OPTIONAL

RD

CM
COMP

CH
NOTE #3

FC
FC

RVC

L1

L2
SUPPLY VOLTAGE
208-240/1/60
CH

C
CH
CM
COMP
DC
DFT
EBTDR
EM
FC
GND
HVDR
LPS
LVDR
LVJB
PLF
RVC
RCCF

T1
C

COMP

C
S

DF1

RCCF

DF2

HVDR

PLF

F
S.A.

CM

NOTE #5

M1

NC

COMPONENT LEGEND

SEE NOTE #3
T2

WARNING

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

RD

GR
BL

NOTE#2

EBTDR

EBTDR

M2

COM

NO

EM
FC
208-240
NOTE #4

2
3

SA
TR

CONTACTOR
CRACKCASE HEATER
CONDENSER MOTOR
COMPRESSOR
DEFROST CONTROL
DEFROST THERMOSTAT
ELECTRONIC BLOWER TIME DELAY RELAY
EVAPORATOR MOTOR
FAN CAPACITOR
EQUPIMENT GROUND
HIGH VOLTAGE DEFROST RELAY
LOW PRESSURE SWITCH
LOW VOLTAGE DEFROST RELAY
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
REVERSING VAVLE COIL
RUN CAPACITOR FOR
COMPRESSOR AND FAN
START ASSIST
TRANSFORMER

FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTINAL HIGH
VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE

WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PU PURPLE
RD RED
WH WHITE
YL YELLOW

TR
24V
EBTDR

NOTES:
R

DFT

DFT

1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT
LEAST 105C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED REPLACE LEAD ON EBTDR "COM" WITH LEAD
ON EBTDR "M1" OR "M2"
3. CRANKCASE HEAT NOT SUPPLIED ON ALL UNITS.
4. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM TERMINAL 3
TERMINAL 2 ON TRANSFORMER.
5. START ASSIST FACTOR EQUIPED WHEN REQUIRED
6. USE COPPER CONDUCTORS ONLY
++ USE N.E.C. CLASS 2 WIRE

C
DC
Y

W2
LVDR

RVC
O
O

4
P
L
F

LPS

SEE UNIT RATING PLATE FOR TYPE AND SIZE


OF OVER CURRENT PROTECTION

6
R

W2

W1

THERMOSTAT

208-240/1/60 0140G00034P

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

48

WIRING DIAGRAMS

GPH1360H21*A*A
PU
BK

RD

NOTE #3

RD
2

IBR

208

240

PU

PU

BL

BK

2
0
8
2
4
0
/
1
/
6
0

TR

BL

RD

24V

RD

BL
RD

WH

GR

BK
BK

T1

SEE NOTE 5

L1

YL

BL

GR

L2

T2

RD

BL

WH

BK

BK

BK

YL
GND

GR
RD

PU

OR

RD

OR

YL
RD

O
O

LVJB

YL

BK

BR

LVDR
WH

W2
R

RD

BL
RD

DF1

DF2

WH

DFT
RD

RCCF

GR

RD

YL

WH
GR

BL

PLF

BK
R

HVDR

BR

YL
RD
GR
WH
OR
BR
BL

Y
R
G
W1
O
W2
C

RD
PU

++

BR
SA (IF USED)
SEE NOTE 4

PU

BK

PU

BK

T
H
E
R
M
O
S
T
A
T

RD
CONTROL
BOX

BK
RD RD

GR
C

G N

YL

BR
S
DFT

EM

C R

CM

BK BK

LPS
COMP

RVC

SEE NOTE 2

L1

L2
SUPPLY VOLTAGE
208-240/1/60

T2
C

COMP

C
S

DF1

DF2

HVDR

RCCF

(HIGH VOLT)

F
S.A.

CM

NOTE #4

IF USED
NOTE #2

L
N

EM

COMPONENT LEGEND
C
CM
COMP
DC
DFT
EM
GND
HVDR
IBR
LPS
LVDR
LVJB
PLF
RVC
RCCF

T1
C

WARNING

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

DC

SA
TR

208-240
NOTE #3

2
3

CONTACTOR
CONDENSER MOTOR
COMPRESSOR
DEFROST CONTROL
DEFROST THERMOSTAT
EVAPORATOR MOTOR
EQUIPMENT GROUND
HIGH VOLTAGE DEFROST RELAY
INDOOR BLOWER RELAY
LOW PRESSURE SWITCH
LOW VOLTAGE DEFROST RELAY
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
REVERSING VAVLE COIL
RUN CAPACITOR FOR
COMPRESSOR AND FAN
START ASSIST
TRANSFORMER

FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTINAL HIGH
VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE

WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PU PURPLE
RD RED
WH WHITE
YL YELLOW

TR
24V

NOTES:

DFT

DC

DFT

Y
W2

RVC
O
LVDR
2
O

1 EM C
SEE NOTE #2

4
5

1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT
LEAST 105C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE LEAD FROM EM "1" TO "2" OR "3".
TERMINAL "3" IS HIGHEST SPEED.
3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM TERMINAL 3
TO
TERMINAL 2 ON TRANSFORMER.
4. START ASSIST FACTOR EQUIPED WHEN REQUIRED
5. USE COPPER CONDUCTORS ONLY
++ USE N.E.C. CLASS 2 WIRE

IBR

6
1

PLF

3
C

LPS

SEE UNIT RATING PLATE FOR TYPE AND SIZE


OF OVER CURRENT PROTECTION
R

W2

W1

THERMOSTAT

208-240/1/60 0140G00081P

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

49

WIRING DIAGRAMS

GPH1324-48H21AB/AC/AD
PU
BK

BK
RD

1
RD

GR
G
BL

EBTDR

R
XFMR-R
XFMR-C
C

NO

K1

COM

PU

NOTE #2 NC
M1 M2

SPEED
UP

BK
T2

L2

T1

L1

BK
BK

RD

RD

RD
RD

BL
BL

PU

BL

BL

24V

BK

K1

NOTE #4
PU

208 240
TR

BR

BK

SEE NOTE #6

OR
RD
OR

YL
BK

2
0
8
2
4
0
/
1
/
6
0

YL

BL

GND
OR

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

DC

OR

C
Y

PU

RD

O
BK

LVDR

RD

YL
BK
YL

BK

BR

RD

R
RD

YL
RD
GR
WH
OR
BR
BL

BL

BK
R

HVDR

LVJB

BUSHING
WH
WH

PU

W2

RD

YL

PLF

DFT
DF1

DF2

RD

RD

RCCF

SA
RD

BR

PU

RD

RD

BL

BK

LOW
BK

PU

EM

S C R

2 SPEED
OPTIONAL

OR

CM
COMP

FC

CH
NOTE #3

FC

RVC

L1

L2
SUPPLY VOLTAGE
208-240/1/60
CH
SEE NOTE #3
T2
C

COMPONENT LEGEND
BR
C
CH
CM
COMP
DC
DFT
EBTD
R
EM
FC
GND
HVDR
LPS
LVDR
LVJB
PLF
RVC
RCCF

T1
C

CO MP

DF1

RCCF

DF2

HVDR
F

S.A.

WARNING

LPS

OR

EM
BR

BK

CONTROL
BOX

YL

BR

HIGH
BR

DFT

3 SPEED

BK

PU

BK
(COM)BK

T
H
E
R
M
O
S
T
A
T

RD

(TRANS240V)
PU (M1) RD

RD

BK

BR

++

BR
(IF USED)
SEE NOTE #5

PU

Y
R
G
W1
O
W2
C

NOTE #5

BR
1

1 P
L
3 F

3
4
M1

CM

NOTE#2

EBTDR

M2

EBTDR

NO

COM

EM
FC

SA
TR

208-240
NOTE #4

2
3

BLOWER INTERLOCK RELAY


CONTACTOR
CRACKCASE HEATER
CONDENSER MOTOR
COMPRESSOR
DEFROST CONTROL
DEFROST THERMOSTAT
ELECTRONIC BLOWER TIME DELAY
RELAY
EVAPORATOR MOTOR
FAN CAPACITOR
EQUPIMENT GROUND
HIGH VOLTAGE DEFROST RELAY
LOW PRESSURE SWITCH
LOW VOLTAGE DEFROST RELAY
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
REVERSING VAVLE COIL
RUN CAPACITOR FOR
COMPRESSOR AND FAN
START ASSIST
TRANSFORMER

FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTINAL HIGH
VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE

WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PU PURPLE
RD RED
WH WHITE
YL YELLOW

TR
24V

EBTDR
R

DFT

DFT

DC
Y

NOTES:

W2
RVC

LVDR
O
O
P 4
L
F 5

6
R

W2

W1

THERMOSTAT

1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS


ORIGINAL (AT
LEAST 105C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED REPLACE LEAD ON EBTDR
"COM" WITH LEAD
ON EBTDR "M1" OR "M2"
3. CRANKCASE HEAT NOT SUPPLIED ON ALL UNITS.
4. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES
FROM TERMINAL 3
TERMINAL 2 ON TRANSFORMER.
5. START ASSIST FACTOR EQUIPED WHEN REQUIRED
6. USE COPPER CONDUCTORS ONLY
++ USE N.E.C. CLASS 2 WIRE
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
208-240/1/60 0140G00365 REV. B

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

50

WIRING DIAGRAMS

GPH1360H21AB-AD
NOTE #3

PU
BK

PU
1

208

240

PU
BL
BK

TR

BL

RD

24V

RD

BL
BL

BK
BK

BL

2
0
8
2
4
0
/
1
/

L2

T2

SEE NOTE 5

L1

T1

YL
RD

BK

YL
GND

GR

GR

60
DC

RD

OR

RD

Y
PU

YL
RD

O
O

YL

BK

LVJB

RD
BR

WH

LVDR

WH

W2
R

YL

BL

RD

PLF

BK

GR

DFT
DF1

DF2

WH
GR

BL

HVDR

RD
RD

RCCF

WH

YL

RD

BR

YL
RD
GR
WH
OR
BR
BL

Y
R
G
W1
O
W2
C

RD
PU

++

BR

RD

GR
C

L G N

PU BR BK

RD RD

T
H
E
R
M
O
S
T
A
T

BK

PU

SA (IF USED)
SEE NOTE 4

CONTROL
BOX

BK
YL
S C R

4 5
DFT

CM

BK BK

LPS

EM

COMP
RVC

SEE NOTE 2

L1

L2
SUPPLY VOLTAGE
208-240/1/60

T2
C

COMP

C
S

DF1

DF2

HVDR

RCCF

(HIGH VO LT)

F
S.A.

CM

NOTE #4

IF USED
NOTE #2

L
N

EM
1

SA
TR

COMPONENT LEGEND
C
CM
COMP
DC
DFT
EM
GND
HVDR
LPS
LVDR
LVJB
PLF
RVC
RCCF

T1
C

WARNING

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

OR

CONTACTOR
CONDENSER MOTOR
COMPRESSOR
DEFROST CONTROL
DEFROST THERMOSTAT
EVAPORATOR MOTOR
EQUIPMENT GROUND
HIGH VOLTAGE DEFROST RELAY
LOW PRESSURE SWITCH
LOW VOLTAGE DEFROST RELAY
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
REVERSING VAVLE COIL
RUN CAPACITOR FOR^J
COMPRESSOR AND FAN
START ASSIST
TRANSFORMER

FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTINAL HIGH
VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE

WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PU PURPLE
RD RED
WH WHITE
YL YELLOW

208-240
NOTE #3

TR
24V

NOTES:

DFT

DC

DFT

1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS


ORIGINAL (AT LEAST 105C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW
LEADS FROM EM"2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE
ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM
TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4. START ASSIST FACTOR EQUIPED WHEN REQUIRED
5. USE COPPER CONDUCTORS ONLY
++ USE N.E.C. CLASS 2 WIRE

Y
W2

RVC
O
LVDR

1 EM C
4
SEE NOTE #2

5
6

PLF

LPS

SEE UNIT RATING PLATE FOR TYPE AND SIZE


OF OVER CURRENT PROTECTION
R

W2

W1

THERMOSTAT

208-240/1/60 0140G00408

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

51

WIRING DIAGRAMS

GPH1324-48M21A*
PU
BK

BK
RD

GR
G
BL

EBTDR

R
XFMR-R
XFMR-C
C

NO

K1

COM

PU

BK
T2

L2

T1

L1

BK
BK

RD

RD

NOTE #2 NC
M1 M2

SPEED
UP

RD
RD

BL
BL

PU

BL

BL

24V

BK

K1

NOTE #4
PU

208 240
TR

RD

BR

BK

SEE NOTE #6

OR
RD
OR

YL
BK

2
0
8
2
4
0
/
1
/
6
0

YL

BL

GND
OR
OR

C
Y

PU

RD

LVDR

RD

YL

O
BK

BK
YL

BK

BR

RD

R
RD

YL
RD
GR
WH
OR
BR
BL

BL

BK
R

HVDR

LVJB

BUSHING
WH
WH

PU

W2

RD

YL

PLF

DFT
DF1

DF2

RD

RD

RCCF

SA
RD

BR

PU

RD

RD

BL

BK

LOW
PU

(COM)BK
EM

CONTROL
BOX
S C R
LPS

OR

EM
BR

BK

BK

YL

BR

HIGH
BR

DFT

3 SPEED

BK

PU

BK

BR

++

T
H
E
R
M
O
S
T
A
T

RD

(TRANS240V)
PU (M1) RD

RD

BK

PU

Y
R
G
W1
O
W2
C

BR
(IF USED)
SEE NOTE #5

2 SPEED
OPTIONAL

OR

CM
COMP

FC

CH
NOTE #3

FC

RVC

L1

L2
SUPPLY VOLTAGE
208-240/1/60
CH
SEE NOTE #3
T2
C

COMPONENT LEGEND
BR
C
CH
CM
COMP
DC
DFT
EBTD
R
EM
FC
GND
HVDR
LPS
LVDR
LVJB
PLF
RVC
RCCF

T1
C

CO MP

DF1

RCCF

DF2

HVDR
F

S.A.

WARNING

BR
3

1 P
L
3 F

CM

NOTE #5

M1

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

DC

NOTE#2

EBTDR

M2

EBTDR

NO

COM

EM
FC

SA
TR

208-240
NOTE #4

2
3

BLOWER INTERLOCK RELAY


CONTACTOR
CRACKCASE HEATER
CONDENSER MOTOR
COMPRESSOR
DEFROST CONTROL
DEFROST THERMOSTAT
ELECTRONIC BLOWER TIME DELAY
RELAY
EVAPORATOR MOTOR
FAN CAPACITOR
EQUPIMENT GROUND
HIGH VOLTAGE DEFROST RELAY
LOW PRESSURE SWITCH
LOW VOLTAGE DEFROST RELAY
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
REVERSING VAVLE COIL
RUN CAPACITOR FOR
COMPRESSOR AND FAN
START ASSIST
TRANSFORMER

FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTINAL HIGH
VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE

WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PU PURPLE
RD RED
WH WHITE
YL YELLOW

TR
24V

EBTDR
R

DFT

DFT

DC
Y

NOTES:

W2
RVC

LVDR
O
O
P 4
L
F 5

6
R

W2

W1

THERMOSTAT

1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS


ORIGINAL (AT
LEAST 105C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED REPLACE LEAD ON EBTDR
"COM" WITH LEAD
ON EBTDR "M1" OR "M2"
3. CRANKCASE HEAT NOT SUPPLIED ON ALL UNITS.
4. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES
FROM TERMINAL 3
TERMINAL 2 ON TRANSFORMER.
5. START ASSIST FACTOR EQUIPED WHEN REQUIRED
6. USE COPPER CONDUCTORS ONLY
++ USE N.E.C. CLASS 2 WIRE
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
208-240/1/60 0140G00365 REV. B

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

52

WIRING DIAGRAMS

GPH1360M21A*
NOTE #3

PU
BK

PU

PU
1

208

240

BL
BK

TR

BL

RD

24V

BL
BL

BK
BK

BL

2
0
8
2
4
0
/
1
/

L2

T2

RD

SEE NOTE 5

L1

T1

YL
RD

BK

YL
GND

GR

GR

60
DC

RD

OR

RD

OR
Y
PU

YL
RD

O
O

YL

BK

LVJB

RD
BR

WH

LVDR

WH

W2
R

YL

BL

RD

BL

GR

DFT
DF1

DF2

WH
GR

PLF

BK
R

HVDR

RD
RD

RCCF

WH

YL

RD

BR

YL
RD
GR
WH
OR
BR
BL

Y
R
G
W1
O
W2
C

RD
PU

++

BR

RD

GR
C

L G N

PU BR BK

RD RD

T
H
E
R
M
O
S
T
A
T

BK

PU

SA (IF USED)
SEE NOTE 4

CONTROL
BOX

BK
YL
S C R

4 5
DFT

CM

BK BK

LPS

EM

COMP
RVC

SEE NOTE 2

L1

L2
SUPPLY VOLTAGE
208-240/1/60

T2
C

COMP

C
S

DF1

DF2

HVDR

RCCF

(HIGH VO LT)

F
S.A.

CM

NOTE #4

IF USED
NOTE #2

L
N

EM
1

SA
TR

COMPONENT LEGEND
C
CM
COMP
DC
DFT
EM
GND
HVDR
LPS
LVDR
LVJB
PLF
RVC
RCCF

T1
C

WARNING

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

CONTACTOR
CONDENSER MOTOR
COMPRESSOR
DEFROST CONTROL
DEFROST THERMOSTAT
EVAPORATOR MOTOR
EQUIPMENT GROUND
HIGH VOLTAGE DEFROST RELAY
LOW PRESSURE SWITCH
LOW VOLTAGE DEFROST RELAY
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
REVERSING VAVLE COIL
RUN CAPACITOR FOR^J
COMPRESSOR AND FAN
START ASSIST
TRANSFORMER

FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTINAL HIGH
VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE

WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PU PURPLE
RD RED
WH WHITE
YL YELLOW

208-240
NOTE #3

TR
24V

NOTES:

DFT

DC

DFT

1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS


ORIGINAL (AT LEAST 105C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW
LEADS FROM EM"2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE
ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM
TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4. START ASSIST FACTOR EQUIPED WHEN REQUIRED
5. USE COPPER CONDUCTORS ONLY
++ USE N.E.C. CLASS 2 WIRE

Y
W2

RVC
O
LVDR

1 EM C
4
SEE NOTE #2

5
6

PLF

LPS

SEE UNIT RATING PLATE FOR TYPE AND SIZE


OF OVER CURRENT PROTECTION
R

W2

W1

THERMOSTAT

208-240/1/60 0140G00408

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

53

54

L1 L2

BK

BK

M2

M1

PU
BL

BK

BK

ONE (1) ELEMENT ROWS

HTR1 TL

BK

FL

GPH1360H21**
WITH
HKR 5 KW

8
9

4
5

2
3

PLF

PLM

WH

BR

BL

L G
2

PU

BK

GR

BL

GR

SEE NOTE 2

PU

BK

RD

WARNING

EM

PU

DF2
DF1

GR

DC

GR

IBR

LVDR

HVDR

BL

DFT

W2

BK

YL

BL

RVC

BR

BL

RD

RCCF

YL

WH

YL

WH

RD

RD

OR

WH

BK

DFT BK BK

RD RD

RD

RD

BL

WH

RD

RD

RD

BL

GR

RD

WH

PU

PU

BL

NOTE #3
PU

SA (IF USED)
SEE NOTE 4

208 240
TR
24V

BK

BR

PU

CM

BR

BR

BK

BK

BR

BK

YL

RD

BK

RD

RD

YL

COMP

S C R

RD

GR

OR

BK

YL

BK
BK

RD

BL

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

PU

GND

SEE NOTE 5

LVBJ

LPS

OR
BR
BL

YL
RD
GR
WH

BK

CONTROL
BOX

++

Y
R
G
W1
O
W2
C

WIRING DIAGRAMS
GPH1360H21A/AA with HKR-05

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

GPH1324-48H21AB
with
5 KW HKR

BR

BL

PU

BK

PU
BK

PU

FC

BK

BR

BL

BL

RD

WARNING

RD

BL
BR

PU

COM

NO

PU

RD

DFT

RD

BK

SA

PU

PU

FC

RD

BR

HIGH

BL

PU

BL

BK

BR

RD

BR

(COM) BK

RD

RD

RD

RD

OR

RD

BK

BL

BK

BK

BK

BK

BL

RD

NC
M2

DF1

DC

M1

EBTDR

DF2

EM

GR

RD

BK

EM

BUSHING

OR

BL

PU

NOTE #4

BK

PU

PU

CM

BR

BR

BK

BK

BR

BK

BK

RD

BK

BK
BK

RD
RD

BL

COMP

S C

RD

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

RD
RD

LPS

OR
BR
BL

RD
GR

LVJB

GND

SEE NOTE #6

RD
RD
RD

BK

CH

PU

T
H
E
R
M
O
S
T
A
T

CONTROL

R
G

2
4
0
/
1
/
6
0

2
0
8

WIRING DIAGRAMS
GPH1324-48H21AB/AC/AD with HKR-05

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

55

56

L1 L2

BK

BK

M2

M1

PU
BL

BK

BK

ONE (1) ELEMENT ROWS

HTR1 TL

BK

FL

8
9

4
5

2
3

PLF

PLM

GPH1360H21AB
with
5 KW HKR

WH

BR

BL

BK

BL

SEE NOTE 2

L
2

WH

GR

PU

WARNING

BR

EM

4 5

G N

YL

PU

DF2

HVDR

GR

WH

DF1

DC

GR

LVDR

BL

DFT

W2

RD

WH

BK

YL

RVC

DFT

BK

BK BK

RD RD

RD

BL

YL

RD

RD

WH

OR

BL

RD

RCCF

YL

BL

RD

RD

BR

24V

TR

RD

BL

GR

PU

PU

BL

WH

NOTE #3

SA (IF USED)
SEE NOTE 4

3
240

2
208

BK
1

PU

BK

CM

BR BK

BR

BR

PU

YL

RD

RD
T1

T2

RD

YL

COMP

S C R

RD

GR

OR

BK

YL

BK
BK

RD

BL

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

L1

L2

PU

LVJB

LPS

YL
RD
GR
WH
OR
BR
BL

BK

GND

SEE NOTE 5

CONTROL
BOX

++

Y
R
G
W1
O
W2
C

T
H
E
R
M
O
S
T
A
T

60

2
0
8
2
4
0
/
1
/

WIRING DIAGRAMS
GPH1360H21AB-AD with HKR-05

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

GPH1324-36M21*
with
GPH1324-48H21AB
with
5KW
HKR
5 KW HKR

BR

BL

PU

BK

PU
BK

WARNING

FC

BK

BR

BL
PU

RD

BL

RD

BL
BR

PU

COM

NO

PU

RD

DFT

RD

BK

SA

PU

PU

FC

RD

BR

HIGH

BL

PU

BL

BK

BR

RD

BR

(COM) BK

RD

RD

RD

RD

OR

RD

BK

BL

BK

BK

BK

BK

BL

RD

NC
M2

DF1

DC

M1

EBTDR

DF2

EM

GR

RD

BK

EM

BUSHING

OR

BL

PU

NOTE #4

BK

PU

PU

CM

BR

BR

BK

BK

BR

BK

BK

RD

BK

BK
BK

RD
RD

BL

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

COMP

S C

RD

RD
RD

LPS

OR
BR
BL

RD
GR

LVJB

GND

SEE NOTE #6

RD
RD
RD

BK

CH

PU

CONTROL

R
G

T
H
E
R
M
O
S
T
A
T

2
4
0
/
1
/
6
0

2
0
8

WIRING DIAGRAMS
GPH1324-36M21* with HKR-05

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

57

58

L1 L2

BK

BK

M2

M1

PU
BL

BK

BK

ONE (1) ELEMENT ROWS

HTR1 TL

BK

FL

8
9

4
5

PLF

PLM

GPH1360H21AB
with
with
5 KW
HKR
5 KW
HKR

GPH1348-60M21*

WH

BR

BL

BK

BL

SEE NOTE 2

L
2

WH

GR

PU

WARNING

BR

EM

4 5

G N

YL

PU

DF2

HVDR

GR

WH

DF1

DC

GR

LVDR

BL

DFT

W2

RD

WH

BK

YL

RVC

DFT

BK

BK BK

RD RD

RD

BL

YL

RD

RD

WH

OR

BL

RD

RCCF

YL

BL

RD

RD

BR

24V

RD

BL

GR

PU

PU

BL

WH

NOTE #3

SA (IF USED)
SEE NOTE 4

240

C
TR

2
208

BK
1

PU

BK

CM

BR BK

BR

BR

PU

YL

RD

RD
T1

T2

RD

YL

COMP

S C R

RD

GR

OR

BK

YL

BK
BK

RD

BL

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

L1

L2

PU

LVJB

LPS

YL
RD
GR
WH
OR
BR
BL

BK

GND

SEE NOTE 5

CONTROL
BOX

++

Y
R
G
W1
O
W2
C

T
H
E
R
M
O
S
T
A
T

60

2
0
8
2
4
0
/
1
/

WIRING DIAGRAMS
GPH1348-60M21* with HKR-05

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

L1 L2

BK
R

FL

FL

M2

M1

R
BK
BK

HTR1 TL

HTR2 TL

BK

TWO (2) ELEMENT ROWS

M4

M3

PU
BL

BK

GPH1360H21**
WITH
HKR 10 KW

8
9

7
8

4
5

2
3

PLF

PLM

WH

BR

BL

PU

L G N

BK

GR

BL

GR

SEE NOTE 2

PU

BK

RD

WARNING

EM

PU

DF2

GR

DF1

GR

IBR

DC

LVDR

HVDR

BL

DFT

W2

BK

YL

BL

RVC

BR

YL

WH

RD

BL

RD

RCCF

YL

WH

RD

OR

WH

BK

DFT BK BK

RD RD

RD

RD

BL

WH

RD

RD

GR

RD

BL

RD

WH

PU

PU

BL

NOTE #3
PU

SA (IF USED)
SEE NOTE 4

208 240
TR
24V

BK

BR

PU

CM

BR

BR

BK

BK

BR

BK

YL

RD

BK

RD

RD

YL

COMP

S C R

RD

GR

OR

BK

YL

BK
BK

RD

BL

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

PU

GND

SEE NOTE 5

LVBJ

LPS

OR
BR
BL

YL
RD
GR
WH

BK

CONTROL
BOX

++

Y
R
G
W1
O
W2
C

WIRING DIAGRAMS
GPH1360H21A/AA with HKR-10

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

59

60

L1 L2

BK
R

FL

FL

M2

M1

R
BK
BK

HTR1 TL

HTR2 TL

BK

TWO (2) ELEMENT ROWS

M4

M3

PU
BL

BK

8
9

7
8

4
5

2
3

PLF

PLM

GPH1324-48H21AB
with
10 KW HKR

WH

BR

BL

PU

BK

PU
BK

WARNING

FC

PU

RD

BK

BR

BL

BL

EM

BL
BR

PU

3 SPEED

RD

WH

DF2

HVDR

LVDR

NO

DFT

W2

PU

RVC

BK

BK

SA

YL

RD

PU

(COM) BK

RD

BR

HIGH
BR

FC

BK

(IF USED)
SEE NOTE #5

WH

BUSHING

OR

BR

NOTE #4

PU
BL

OPTIONAL

2 SPEED

EM

LOW

BL

PU

BL

24V

TR

RCCF

BK

208 240

BR

PU

(TRANS240V)
PU (M1) RD

RD

RD

YL

RD

RD

OR

RD

BK

BL

WH BK

RD

DFT

RD

RD

BK

YL

BK

BL

RD

COM
NC
M2

DF1

DC

M1

NOTE #2

K1

K1

EBTDR

SPEED
UP

XFMR-R
XFMR-C

GR

RD

BK

PU

PU

CM

BR

BR

BK

BK

BR

BK

BK

YL

RD

BK

YL

BK
BK

RD
RD

BL

RD

T1

T2

YL

COMP

S C R

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

CH

LVJB

LPS

YL
RD
GR
WH
OR
BR
BL

GND

SEE NOTE #6

RD
RD
RD

BK

NOTE #3

RD
RD

L1

L2

PU

T
H
E
R
M
O
S
T
A
T

CONTROL
BOX

++

Y
R
G
W1
O
W2
C

2
0
8
2
4
0
/
1
/
6
0

WIRING DIAGRAMS
GPH1324-48H21AB/AC/AD with HKR-10

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

L1 L2

BK
R

FL

FL

M2

R
BK
BK

M1

HTR1 TL

HTR2 TL

BK

TWO (2) ELEMENT ROWS

M4

M3

PU
BL

BK

GPH1360H21AB
with
10 KW HKR

8
9

7
8

4
5

2
3

PLF

PLM

WH

BR

BL

BK

BL

SEE NOTE 2

WH

GR

PU

WARNING

BR

EM

4 5

G N

YL

PU

DF2

HVDR

GR

WH

DF1

DC

GR

LVDR

BL

DFT

W2

RD

WH

BK

YL

RVC

DFT

BK

BK BK

RD RD

RD

BL

RD

WH

OR

YL

RD

BL

RD

RCCF

YL

BL

RD

RD

BR

24V

TR

RD

BL

GR

BR
BK

BR

PU

CM

PU BR BK

PU

BL

WH

NOTE #3

SA (IF USED)
SEE NOTE 4

3
240

2
208

BK

PU

YL

RD

RD
T1

T2

RD

YL

COMP

S C R

RD

GR

OR

BK

YL

BK
BK

RD

BL

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

L1

L2

PU

LVJB

LPS

YL
RD
GR
WH
OR
BR
BL

BK

GND

SEE NOTE 5

CONTROL
BOX

++

W2
C

Y
R
G
W1
O

T
H
E
R
M
O
S
T
A
T

60

2
0
8
2
4
0
/
1
/

WIRING DIAGRAMS
GPH1360H21AB-AD with HKR-10

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

61

62

L1 L2

BK
R

FL

FL

M2

R
BK
BK

M1

HTR1 TL

HTR2 TL

BK

TWO (2) ELEMENT ROWS

M4

M3

PU
BL

BK

8
9

7
8

4
5

2
3

PLF

PLM

with
GPH1324-48H21AB
10with
KW HKR
10 KW HKR

GPH1324-36M21*

WH

BR

BL

PU

BK

PU
BK

WARNING

FC

PU

RD

BK

BR

BL

BL

EM

BL
BR

PU

3 SPEED

RD

WH

DF2

HVDR

LVDR

DFT

W2

PU

RVC

BK

BK

SA

YL

PU

(COM) BK

RD

BR

HIGH
BR

FC

BK

(IF USED)
SEE NOTE #5

WH

BUSHING

OR

BR

NOTE #4

PU
BL

OPTIONAL

2 SPEED

EM

LOW

BL

PU

BL

24V

TR

RCCF

BK

208 240

BR

PU

(TRANS240V)
PU (M1) RD

RD

RD

YL

RD

RD

RD

OR

RD

BK

BL

WH BK

RD

DFT

RD

RD

BK

YL

BK

BL

RD

COM

NO

NC
M2

DF1

DC

M1

NOTE #2

K1

K1

EBTDR

SPEED
UP

XFMR-R
XFMR-C

GR

RD

BK

PU

PU

CM

BR

BR

BK

BK

BR

BK

BK

YL

RD

BK

YL

BK
BK

RD
RD

BL

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

YL

COMP

S C R

RD

T1

T2

CH

LVJB

LPS

YL
RD
GR
WH
OR
BR
BL

GND

SEE NOTE #6

RD
RD
RD

BK

NOTE #3

RD
RD

L1

L2

PU

T
H
E
R
M
O
S
T
A
T

CONTROL
BOX

++

Y
R
G
W1
O
W2
C

2
0
8
2
4
0
/
1
/
6
0

WIRING DIAGRAMS
GPH1324-36M21* with HKR-10

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

L1 L2

BK
R

FL

FL

M2

R
BK
BK

M1

HTR1 TL

HTR2 TL

BK

TWO (2) ELEMENT ROWS

M4

M3

PU
BL

BK

8
9

7
8

4
5

2
3

PLF

PLM

GPH1348-60M21*
GPH1360H21AB
with
with
1010
KW
HKR
KW
HKR

WH

BR

BL

BK

BL

SEE NOTE 2

WH

GR

PU

WARNING

BR

EM

4 5

G N

YL

PU

DF2

HVDR

GR

WH

DF1

DC

GR

LVDR

BL

DFT

W2

RD

WH

BK

YL

RVC

DFT

BK

BK BK

RD RD

RD

BL

RD

WH

OR

YL

RD

BL

RD

RCCF

YL

BL

RD

RD

BR

24V

TR

RD

BL

GR

BR
BK

BR

PU

CM

PU BR BK

PU

BL

WH

NOTE #3

SA (IF USED)
SEE NOTE 4

3
240

2
208

BK
1

PU

YL

RD

RD
T1

T2

RD

YL

COMP

S C R

RD

GR

OR

BK

YL

BK
BK

RD

BL

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

L1

L2

PU

LVJB

LPS

YL
RD
GR
WH
OR
BR
BL

BK

GND

SEE NOTE 5

CONTROL
BOX

++

W2
C

Y
R
G
W1
O

T
H
E
R
M
O
S
T
A
T

60

2
0
8
2
4
0
/
1
/

WIRING DIAGRAMS
GPH1348-60M21* with HKR-10

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

63

64

M2

M1

BK

BK

PLM
PLF

M2
R2

M1

BL

PU

6
7
8
9

7
8
9

BR 5
6

R
BL

2
3

THREE (3) ELEMENT ROWS

BK
R

R1

M4

M3

HTR3 TL

L1 L2 L1 L2

BK

BK

BL

BL

WH

BR

BK

PU

SEE NOTE 2

L G N
2

GR

EM

PU

DF2

HVDR

DF1

GR

DFT

W2

TL

FL HTR2
O

O
LVDR

DC

GR

BL

IBR

BK

PU

BK

GR

TL
FL HTR1

FL

GPH1360H21**
WITH
HKR 15 KW

RD

WARNING

BK

YL

BL

RVC

BR

YL

WH

RD

BL

RD

RCCF

YL

WH

RD

OR

WH

BK

DFT BK BK

RD RD

RD

RD

BL

WH

RD

RD

RD

BL

GR

RD

WH

PU

PU

BL

NOTE #3
PU

SA (IF USED)
SEE NOTE 4

208 240
TR
24V

BK

BR

PU

CM

BR

BR

BK

BK

BR

BK

YL

RD

BK

RD

RD

YL

COMP

S C R

RD

GR

OR

BK

YL

BK
BK

RD

BL

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

PU

GND

SEE NOTE 5

LVBJ

LPS

OR
BR
BL

YL
RD
GR
WH

BK

CONTROL
BOX

++

Y
R
G
W1
O
W2
C

WIRING DIAGRAMS
GPH1360H21A/AA with HKR-15

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

BK

M2

M1

Y BK

PU

M2
R2

M1

BL

6
7
8
9

7
8
9

BR 5
6

2
3

PLF

R
BL

BK

PLM

THREE (3) ELEMENT ROWS

BK
R

R1

M4

M3

HTR3 TL

L1 L2 L1 L2

BK

TL

FL HTR2

BK

TL
FL HTR1

FL

GPH1324-48H21AB
with
15 KW HKR

WH

BR

BL

PU

BK

PU
BK

WARNING

FC

PU

RD

BK

BR

BL

BL

EM

BL
BR

PU

3 SPEED

RD

WH

DF2

HVDR

LVDR

NO

DFT

W2

PU

RVC

BK

BK

SA

YL

PU

(COM) BK

RD

BR

HIGH
BR

FC

BK

(IF USED)
SEE NOTE #5

WH

BUSHING

OR

BR

NOTE #4

PU
BL

OPTIONAL

2 SPEED

EM

LOW

BL

PU

BL

24V

TR

RCCF

BK

208 240

BR

PU

(TRANS240V)
PU (M1) RD

RD

RD

YL

RD

RD

RD

OR

RD

BK

BL

WH BK

RD

DFT

RD

RD

BK

YL

BK

BL

RD

COM
NC
M2

DF1

DC

M1

NOTE #2

K1

K1

EBTDR

SPEED
UP

XFMR-R
XFMR-C

GR

RD

BK

PU

PU

CM

BR

BR

BK

BK

BR

BK

BK

YL

RD

BK

YL

BK
BK

RD
RD

BL

YL

COMP

S C R

RD

T1

T2

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

CH

LVJB

LPS

YL
RD
GR
WH
OR
BR
BL

GND

SEE NOTE #6

RD
RD
RD

BK

NOTE #3

RD
RD

L1

L2

PU

T
H
E
R
M
O
S
T
A
T

CONTROL
BOX

++

Y
R
G
W1
O
W2
C

2
0
8
2
4
0
/
1
/
6
0

WIRING DIAGRAMS
GPH1324-48H21AB/AC/AD with HKR-15

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

65

66

BK

M2

M1

Y BK

L1 L2 L1 L2

BK

M2
R2

M1

PU

6
7
8
9

7
8
9

BR 5
6

2
3

PLF

R
BL

BK

PLM

THREE (3) ELEMENT ROWS

BK
R

R1

M4

M3

BL

TL
FL HTR2

HTR3 TL

BK

TL
FL HTR1

FL

GPH1360H21AB
with
15 KW HKR

WH

BR

BL

BK

BL

SEE NOTE 2

L
2

WH

GR

PU

WARNING

BR

EM

4 5

G N

YL

PU

DF2

HVDR

GR

WH

DF1

DC

GR

LVDR

BL

DFT

W2

RD

WH

BK

YL

RVC

DFT

BK

BK BK

RD RD

RD

BL

YL

RD

RD

WH

OR

BL

RD

RCCF

YL

BL

RD

RD

BR

24V

TR

RD

BL

GR

PU

PU

BL

WH

NOTE #3

SA (IF USED)
SEE NOTE 4

3
240

2
208

BK
1

PU

BK

CM

BR BK

BR

BR

PU

YL

RD

RD
T1

T2

RD

YL

COMP

S C R

RD

GR

OR

BK

YL

BK
BK

RD

BL

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

L1

L2

PU

LVJB

LPS

YL
RD
GR
WH
OR
BR
BL

BK

GND

SEE NOTE 5

CONTROL
BOX

++

Y
R
G
W1
O
W2
C

T
H
E
R
M
O
S
T
A
T

60

2
0
8
2
4
0
/
1
/

WIRING DIAGRAMS
GPH1360H21AB-AD with HKR-15

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

BK

M2

M1

Y BK

PU

M2
R2

M1

BL

6
7
8
9

7
8
9

BR 5
6

2
3

PLF

R
BL

BK

PLM

THREE (3) ELEMENT ROWS

BK
R

R1

M4

M3

HTR3 TL

L1 L2 L1 L2

BK

TL

FL HTR2

BK

TL
FL HTR1

FL

GPH1324-48H21AB
with
15 KW HKR

WH

BR

BL

PU

BK

PU
BK

WARNING

FC

PU

RD

BK

BR

BL

BL

EM

BL
BR

PU

3 SPEED

RD

WH

DF2

HVDR

LVDR

NO

DFT

W2

PU

RVC

BK

BK

SA

YL

PU

(COM) BK

RD

BR

HIGH
BR

FC

BK

(IF USED)
SEE NOTE #5

WH

BUSHING

OR

BR

NOTE #4

PU
BL

OPTIONAL

2 SPEED

EM

LOW

BL

PU

BL

24V

TR

RCCF

BK

208 240

BR

PU

(TRANS240V)
PU (M1) RD

RD

RD

YL

RD

RD

RD

OR

RD

BK

BL

WH BK

RD

DFT

RD

RD

BK

YL

BK

BL

RD

COM
NC
M2

DF1

DC

M1

NOTE #2

K1

K1

EBTDR

SPEED
UP

XFMR-R
XFMR-C

GR

RD

BK

PU

PU

CM

BR

BR

BK

BK

BR

BK

BK

YL

RD

BK

YL

BK
BK

RD
RD

BL

T1

T2

YL

COMP

S C R

RD

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

CH

LVJB

LPS

YL
RD
GR
WH
OR
BR
BL

GND

SEE NOTE #6

RD
RD
RD

BK

NOTE #3

RD
RD

L1

L2

PU

T
H
E
R
M
O
S
T
A
T

CONTROL
BOX

++

Y
R
G
W1
O
W2
C

2
0
8
2
4
0
/
1
/
6
0

WIRING DIAGRAMS
GPH1324-36M21* with HKR-15

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

67

68

BK

M2

M1

Y BK

L1 L2 L1 L2

BK

M2
R2

M1

PU

6
7
8
9

7
8
9

BR 5
6

2
3

PLF

R
BL

BK

PLM

THREE (3) ELEMENT ROWS

BK
R

R1

M4

M3

BL

TL
FL HTR2

HTR3 TL

BK

TL
FL HTR1

FL

with
GPH1360H21AB
15 with
KW HKR
15 KW HKR

GPH1348-60M21*

WH

BR

BL

BK

BL

SEE NOTE 2

L
2

WH

GR

PU

WARNING

BR

EM

4 5

G N

YL

PU

DF2

HVDR

GR

WH

DF1

DC

GR

LVDR

BL

DFT

W2

RD

WH

BK

YL

RVC

DFT

BK

BK BK

RD RD

RD

BL

YL

RD

RD

WH

OR

BL

RD

RCCF

YL

BL

RD

RD

BR

24V

TR

RD

BL

GR

PU

PU

BL

WH

NOTE #3

SA (IF USED)
SEE NOTE 4

3
240

2
208

BK
1

PU

BK

CM

BR BK

BR

BR

PU

YL

RD

RD
T1

T2

RD

YL

COMP

S C R

RD

GR

OR

BK

YL

BK
BK

RD

BL

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

L1

L2

PU

LVJB

LPS

YL
RD
GR
WH
OR
BR
BL

BK

GND

SEE NOTE 5

CONTROL
BOX

++

Y
R
G
W1
O
W2
C

T
H
E
R
M
O
S
T
A
T

60

2
0
8
2
4
0
/
1
/

WIRING DIAGRAMS
GPH1348-60M21* with HKR-15

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

BK
R

M2

M1

M6

R2

M8

M7

BL

8
9

7
8

BR 5
6

2
3

PLF

PLM

R
BL

BK

FOUR (4) ELEMENT ROWS

BL
BK
R

R1

M4

M3

M5

BL

HTR4TL

BL BK R

TL
FLHTR3

L1 L2 L1 L2

BK

PU

HTR2 TL
FL

FL

BK

HTR1 TL

FL

GPH1360H21**
WITH
HKR 20 KW

WH

BR

BL

L G N
2

PU

BK

GR

BL

GR

SEE NOTE 2

PU

BK

RD

WARNING

EM

HVDR

PU

DF1

GR

DC

GR

IBR

LVDR

DF2

BL

DFT

W2

BK

YL

BL

RVC

BR

YL

WH

RD

BL

RD

RD

GR

RD

BL

RD

WH

PU

PU

BL

NOTE #3
PU

SA (IF USED)
SEE NOTE 4

208 240
TR
24V

BK

BR

PU

RCCF

YL

WH

RD

OR

WH

BK

DFT BK BK

RD RD

RD

RD

BL

WH

RD

CM

BR

BR

BK

BK

BR

BK

YL

RD

BK

RD

YL
RD

COMP

S C R

RD

GR

OR

BK

YL

BK
BK

RD

BL

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

PU

GND

SEE NOTE 5

LVBJ

LPS

OR
BR
BL

YL
RD
GR
WH

BK

CONTROL
BOX

++

Y
R
G
W1
O
W2
C

WIRING DIAGRAMS
GPH1360H21A/AA with HKR-20

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

69

GPH1324-48H21AB
with
20 KW HKR

70
BR

BL

PU

BK

PU

WARNING

BK

FC

PU

RD

BK

BR

BL

BL

RD

BL
BR

PU

NO
COM

PU

RD

DFT

RD

BK

SA

PU

PU

FC

RD

BR

HIGH

BL

PU

BL

BK

BR

RD

BR

(COM) BK

RD

RD

RD

RD

OR

RD

BK

BL

BK

BK

BK

BK

BL

RD

NC
M2

DF1

DC

M1

EBTDR

DF2

EM

GR

RD

BK

EM

BUSHING

OR

BL

PU

NOTE #4

BK

PU

PU

CM

BR

BR

BK

BK

BR

BK

BK

RD

BK

BK
BK

RD
RD

BL

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

COMP

S C

RD

RD
RD

PU

CH

LPS

OR
BR
BL

RD
GR

LVJB

GND

SEE NOTE #6

RD
RD
RD

BK

CONTROL

R
G

T
H
E
R
M
O
S
T
A
T

2
4
0
/
1
/
6
0

2
0
8

WIRING DIAGRAMS
GPH1324-48H21AB/AC/AD with HKR-20

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

BK
R

BK

L1 L2 L1 L2

M2

M1

M6

M5

BL
BK
R

R1

M4

M3

R2

M8

M7

BL

8
9

7
8

BR 5
6

2
3

PLF

PLM

R
BL

BK

FOUR (4) ELEMENT ROWS

BL BK R

BL

HTR4TL

PU

HTR2 TL
FL

TL
FLHTR3

BK

TL
FL HTR1

FL

GPH1360H21AB
with
20 KW HKR

WH

BR

BL

BK

BL

SEE NOTE 2

EM

4 5

L G N
2

BR

YL

WH

GR

PU

WARNING

PU

DF2

HVDR

GR

WH

DF1

DC

GR

LVDR

BL

DFT

W2

RD

WH

BK

YL

RVC

DFT

BK

BK BK

RD RD

RD

BL

YL

RD

RD

WH

OR

BL

RD

RCCF

YL

BL

RD

RD

BR

24V

TR

RD

BL

GR

BR
BK

BR

PU

CM

PU BR BK

PU

BL

WH

NOTE #3

SA (IF USED)
SEE NOTE 4

3
240

2
208

BK
1

PU

YL

RD

RD
T1

T2

C R

RD

COMP

RD

GR

OR

BK

YL

BK
BK

RD

BL

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

YL

L1

L2

PU

LPS

YL
RD
GR
WH
OR
BR
BL

LVJB

BK

GND

SEE NOTE 5

CONTROL
BOX

++

Y
R
G
W1
O
W2
C

T
H
E
R
M
O
S
T
A
T

60

2
0
8
2
4
0
/
1
/

WIRING DIAGRAMS
GPH1360H21AB-AD with HKR-20

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

71

GPH1324-48H21AB
with
20 KW HKR

72
BR

BL

PU

BK

WARNING

PU
BK

FC

PU

RD

BK

BR

BL

BL

RD

BL
BR

PU

NO
COM

PU

RD

DFT

RD

BK

SA

PU

PU

FC

BR

BL

PU

RD

HIGH

BL

BK

BR

RD

BR

(COM) BK

RD

RD

RD

RD

OR

RD

BK

BL

BK

BK

BK

BK

BL

RD

NC
M2

DF1

DC

M1

EBTDR

DF2

EM

GR

RD

BK

EM

BUSHING

OR

BL

PU

NOTE #4

BK

PU

PU

CM

BR

BR

BK

BK

BR

BK

BK

RD

BK

BK
BK

RD
RD

BL

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

COMP

S C

RD

RD
RD

LPS

OR
BR
BL

RD
GR

LVJB

GND

SEE NOTE #6

RD
RD
RD

BK

CH

PU

CONTROL

R
G

T
H
E
R
M
O
S
T
A
T

2
4
0
/
1
/
6
0

2
0
8

WIRING DIAGRAMS
GPH1324-36M21* with HKR-20

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

GPH1348-60M21*
with
20 KW HKR

WH

BR

BL

GR

BL

SEE NOTE 2

WARNING

EM

BR

G N

YL

DC

GR

HVDR

GR

WH

LVDR

BL

RD

WH

YL

RVC

RD RD

RD

BL

RD

OR

YL

RD

BL

RD

RCCF

YL

BL

RD

RD

GR

SA (IF USED)
SEE NOTE 4

RD

BL
BL

CM

BR

YL

RD

RD

YL

RD

BL

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

RD

YL

COMP

C R

RD

GR

T1

T2

LPS

BL

OR

YL
RD
GR

LVJB

GND

SEE NOTE 5

CONTROL
BOX

R
G
W1
O
W2
C

WIRING DIAGRAMS
GPH1348-60M21* with HKR-20

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

73

You might also like