You are on page 1of 6

Industrial Lighting

Fluorescent lighting proves to be insufficient in


the case of factories with ceiling heights. High
Bay luminaires are the preferred choice for such
installations, with the HID lamps used offering a
higher light output compared to fluorescent
lamps.
Industrial Luminaires
Dimensions (mm)
NDC 203
NDC 203
General Description
Well glass luminaire suitable for use with Incandescent (GLS 200W),
Blended ML-N 160W/200W, High Pressure Mercury Vapour HPL-N 80
/ 125 W & High Pressure Sodium Vapour SON 70 (E or I) lamp.
HPL-N and SON lamps are to be operated with appropriate external
control gear box ( ZVX 250 / 80, ZVX 260 / 125, ZVX 270 / 70 I/E.)
Features
! Light weight pressure die-cast aluminium housing (LM6), painted
black outside and white inside, hence no extra reflector is required
! Porcelain lampholder (E-27) pre-wired upto the terminal block. An
earthing terminal is also provided
! Heat resistant and toughened clear glass cover along with a gasket
made of ethylene propylene rubber to ensure satisfactory insect free
performance without the ingress of water
! Pressure die cast aluminium (LM6) ring, hinged to the housing, to
hold the glass cover in place
! Wire guard made of M.S. to protect the luminaire
! Conforms to IP 65 protection
! Conforms to relevant IS specifications
Applications
! Cable galleries / boiler platforms in power stations
! Industries
IP 65
NDC 203
Industrial Luminaires
Compliances
IP 65
Class I
216
Industrial Luminaires
NDC 203
Technical Data
Type For Lamp Nominal Mains Nominal Power
Voltage (V) Current (A) Factor
NDC 203 1 x GLS 200W (max)
NDC 203 1 x ML-N 160W
NDC 203* 1 x HPL-N 80W
NDC 203* 1 x HPL-N 125W
NDC 203* 1 x SON 70W
230
240
240
240
240
0.80
0.72
0.45
0.70
0.45
1.00
0.97
> 0.85
> 0.85
> 0.85
Ordering Data
Type Ordering Quantity Dimensions Net Weight Gross Weight Volume
3
No per box (mm) (Kg) (kg) (m)
NDC 203 1307 11345 1 225 x 275 x 305 1.35 x 1 2.00 0.036
P.C. reflector (optional) 1308 22415 6 380 x 380 x 280 0.90 x 6 6.00 0.040
* To be used with appropriate control gear unit
217
Industrial Luminaires
Dimensions (mm)
NDC 21
NDC 21
Industrial Luminaires
General Description
Well glass luminaire suitable for use with Incandescent (GLS 500W),
High Pressure Mercury Vapour HPL-N 250 W & High Pressure Sodium
Vapour SON 150W / 250 W lamp
HPL-N and SON lamps are to be operated with appropriate external
control gear box ( ZVX 280 /250/240, ZVX 320 / 150 / 240, ZVX 330 /
250 / 240) respectively
Features
! Light weight die-cast aluminium housing (LM6), painted grey outside
and white inside
! A porcelain lampholder (E-40 type) pre-wired upto the terminal
block, an earthing terminals is also provided
! Heat resistant and toughened clear glass cover along with gasket
made of ethylene propylene rubber to ensure satisfactory insect free
performance without the ingress of water
! Pressure die-cast aluminium (LM6) ring hinged to the housing, to
hold the glass cover in place
! Wire guard made of MS to protect the luminaire from damages.
! Conforms to IP 55 protection
! Conforms to relevant IS Specifications
Applications
! Cable galleries / boiler platforms in power stations
! Industries
Installation
! Mounting provision suitable for suspension by means of dia 20 mm
threaded GI pipe.
IP 55
NDC 21
Compliances
IP 55
Class I
218
Industrial Luminaires
NDC 21
Technical Data
Type For Lamp Nominal Mains Nominal Power
Voltage (V) Current (A) Factor
Ordering Data
Type Ordering Quantity Dimensions Net Weight Gross Weight Volume
3
No per box (mm) (Kg) (kg) (m)
NDC 21 1307 11325 1 520 x 520 x 330
Reflector (optional) 1308 11375 20 562 x 562 x 562
6.00 x 1
1.50 x 20
6.50
32.90
0.089
0.178
* To be used with appropriate control gear unit
NDC 21 1 x GLS 500W 1.00
NDC 21* 1 x SON 150 W > 0.85
NDC 21* 1 x SON 250 W > 0.85
NDC 21 * 1 x HPL-N 250 W
250
240
240
240
2.00
0.85
1.40
1.35 > 0.85
219
Industrial Luminaires
Dimensions (mm)
SDL 203
General Description
Integral well glass luminaire suitable for use with High Pressure Sodium
Vapour SON 70W (E or I) lamp or High Pressure Mercury Vapour
HPL-N 80W/125W lamp
Features
! Pressure die-cast aluminium housing of (LM6), which offers excellent
corrosion resistance. It accommodates all the accessories like PF
improvement capacitors, ignitor, ballast, lampholder pre-wired upto
the terminal block
! Heat resistant toughened glass cover with wire guard fixed to the
housing by means of stainless steel toggles
! An adjustable mounting bracket made of M.S., powder coated for
side/top mounting
! Cable entry gland suitable for 10mm dia cable is provided for
incoming cable. Cable entry gland for loop-in-loop-out provision
! Conforms to IP 65 protection
! Conforms to relevant IS specifications
Applications
! Cable galleries / boiler platform
! Power stations
! Industries
SDL 203
Industrial Luminaires
IP 65
SDL 203
Compliances
IP 65
Class I
220
Industrial Luminaires
SDL 203
Technical Data
Type For Lamp Nominal Mains Nominal Power
Voltage (V) Current (A) Factor
Ordering Data
Type Ordering Quantity Dimensions Net Weight Gross Weight Volume
3
No per box (mm) (Kg) (kg) (m)
SDL 203/70W 1 x SON 70W
HDL 203/80W 1 x HPL-N 80W
HDL 203/125W 1 x HPL-N 125W
240
240
240
> 0.85
> 0.85
> 0.85
0.45
0.45
0.70
SDL 203/70(E) 1307 11745 1 290 x 290 x 340 3.00 x 1
SDL 203/70W(I) 1307 11755 1 400 x 350 x 350 3.80 x 1
SON 70W ballast 1220 03285 12 255 x 196 x 118 1.00 x 12
HDL 203/80W 1307 11845 1 390 x 340 x 340 3.80 x 1
3.75
4.20
12.60
4.20
0.049
0.049
0.006
0.045
221
Note : Ballast of suitable rating shall be packed separately (packing data on request)
Industrial Luminaires
Dimensions (mm)
NXC 101/FXC 101
General Description
Bulkhead luminaires suitable for use with GLS 60W (max), PL-S 9W
compact fluorescent lamp
NXC 101 for GLS 60W
FXC 101for PL-S 9W
FXC 101
Industrial Luminaires
Features Features
! Single piece pressure die-cast aluminium (LM6) housing & cover
retaining frame offers excellent corrosion resistance. Three colour
options for housing
! Heat resistant toughened frosted glass cover (NXC 101) or clear /
opal acrylic cover (FXC 101) along with a gasket made of E.P.R. to
ensure satisfactory performance
! Wire guard made of powder coated M.S., to protect the luminaire
from damages
! The luminaires are pre-wired upto a terminal block. In case of FXC
101, a low loss, open construction ballast is also incorporated in the
housing
! Conforms to IP 54 protection
! Conforms to relevant IS specifications
Applications
! Stairways
! Corridors
! Security
IP 54
NXC 101/FXC 101
Compliances
IP 54
Class I
222
Industrial Luminaires
NXC 101/FXC 101
Type For Lamp Nominal Mains Nominal Power
Voltage (V) Current (A) Factor
0.26 1.00
0.17 0.35
Type Ordering Quantity Dimensions Net Weight Gross Weight Volume
3
No per box (mm) (Kg) (kg) (m)
1.20 x 8
1.20 x 8
1.20 x 8
1.00 x 8
1.10 x 8
1.10 x 8
1.10 x 8
10.80
10.80
10.80
9.40
9.40
9.40
9.40
0.044
0.044
0.044
0.044
0.044
0.044
0.044
Technical Data
NXC 101 1 x GLS 60W 230
FXC 101 1 x PL-S 9W 230
Ordering Data
NXC 101 (Grey) 1306 51535 8 325 x 305 x 440
NXC 101 (Black) 1306 51525 8 325 x 305 x 440
NXC 101 (Red) 1306 51545 8 325 x 305 x 440
FXC 101 (Grey) Clear 1306 51555 8 325 x 305 x 440
FXC 101 (Red) Clear 1306 51575 8 325 x 305 x 440
FXC 101 (Grey) Opal 1306 51565 8 325 x 305 x 440
FXC 101 (Red) Opal 1306 51585 8 325 x 305 x 440
223
Industrial Luminaires ENDURA HPK105
General Description
Integral well-glass luminaire suitable for use with High Pressure Sodium
Vapour SON 70W (E or I) lamp or High Pressure Mercury Vapour HPL-
N 80W/125W lamp.
HPK105
Industrial Luminaires
! Cable galleries / boiler platforms.
! Power stations.
! Industries.
Applications
IP 65
Dimensions (mm)
HPK105
Features
148
476
196
210
148
426
Industrial Luminaires
! Pressure die-cast aluminium housing construction with epoxy-
polyester powder coated offers robustness and good weather-ability.
! It accommodates all the accessories like PF improvement capacitors,
ignitor, ballast, lampholder pre-wired upto the terminal block.
!
!
!
! Conforms to IP 65 protection.
Heat resistant toughened glass cover with heavy duty 5mm wire
guard fixed to the housing by means of robust clamps.
Adjustable bracket for top as well as side mounting options.
Profiled EPDM gasket with special hardness treatment so as to
achieve and maintain high ingress protection.
Compliances
IP 65
Class I
224
Industrial Luminaires
ENDURA HPK105
Technical Data
Type For Lamp Nominal Mains Nominal Power
Voltage (V) Current (A) Factor
HPK105 1xSON-E70W 1x SON-E 70W 240 0.45 > 0.85
HPK105 1xSON-I70W 1x SON-I 70W 240 0.45 > 0.85
HPK105 1xHPL-N80W 1x HPL-N 80W 240 0.45 > 0.85
HPK105 1xHPL-N125W 1x HPL-N 125W 240 0.70 > 0.85
Ordering Data
Type Ordering Quantity Dimensions Net Weight Gross Weight Volume
3
No per box (mm) (Kg) (kg) (m)
HPK105 1xSON-E70W 1307 11765 1 255 x 255 x 460 1.80 3.00 0.0299
HPK105 1xSON-I70W 1307 11775 1 255 x 255 x 460 1.80 3.00 0.0299
HPK105 1xHPL-N80W 1307 11865 1 255 x 255 x 460 1.80 3.00 0.0299
HPK105 1xHPL-N125W 1307 11875 1 255 x 255 x 460 1.80 3.00 0.0299
225
Note : Ballast of suitable rating shall be packed separately (packing data on request)