UBA Pressure Relief Valve Sizing & Selection Report
ignaciopianciola@hotmail.com 23-may-2013
Argentina
43878734
ignaciopianciola@hotmail.com
Quote Number: No Prpd. Chk. Appr. Date Revision
Client: My Company
Location: End-User Ref. No.:
Project: Planta de Bioetanol Project Ref. No.:
VALVE ID SIZING DATA
Tag No. PSV-101 Design Code ASME Section VIII Sizing Std. API 520
Service Separador Flash Sizing Basis Fire Case
PID No. 101 Fluid State at Inlet Gas / Vapor
Line No. Quantity Relieving Case Pressure Relief
1 Fluid Properties
GENERAL Fluid Name Mezcla S-001
Valve Type Conventional, Direct Spring-Op Molecular Weight, M 18,79
Safety / Relief Safety Balanced No Compressibility, Z 1
Nozzle Full Bonnet Closed Ratio of Sp. Heats, k (Cp / Cv) 1,22
CONNECTIONS Gas Constant, C 339,2
Inlet 3" Flngd. 150# RF Standard
Outlet 4" Flngd. 150# RF ASME B16.5
MATERIALS OF CONSTRUCTION
Body / Base SS SA351-CF8M
Bonnet / Cylinder SS SA351-CF8M
Nozzle 316 SST
Disc 316 SST
Seat Sizing Coefficients Unit -
Spindle 316 SST Effective K, Gas 0,975
Guide SS A297-HE Kb Kc 1,0 1,0
Spring 316 SST
Gaskets 316 SST
Bellows N/A Required Capacity Unit kg/hr
Cap Type Bolted w/ Test Rod (Ht. Rest.) Total 2590,86
NACE MR0175 (2002) No
A
c
c
e
s
s
o
r
i
e
s
Pressures Unit psig
MAWP Operating
Set CDTP 32,05
Over Pressure 6,730 21%
SIZING / SELECTION SUMMARY
Back
Pressure
Constant Superimposed 0
Valve Model No. 3L4 JOS-E -15-S-H Variable Superimposed 0
Brand Crosby Built-Up 0.94
Area Calculated Selected 2,021 2,853 Total 0.94
(in) Data Set Orifice API L Inlet Loss 0 0.16%
Flow
Unit Required kg/hr 2590,86 Atmospheric (Barometric) 14,696 psia
Maximum 3657,535 Relieving (Flowing) 53,476 psia
Temperatures Unit C
Estimated Reaction Force 45,47 daN Operating Relieving 30 135,7
Estimated Noise Level (db) 104,9 at 100-ft Design Min Design Max
Printed On: 21-jun-2013 Pentair PRVSIZE Software Version pr4.2_20121217.2 Page : 1
Pentair Valves & Controls and its parent, subsidiaries, and affiliates assume no liability in any way whatsoever for any direct or indirect loss or damage through the application of this software. See terms of license
agreement. Not for resale. All rights reserved. All trademarks, trade names and/or registered trademarks referred to in this program are the property of their respective owners. Copyright 2012 Pentair Valves & Controls.
T
a
g

N
o
t
e
s
V
a
l
v
e

D
i
m
e
n
s
i
o
n
s
i
n
A
6,13
B
6,5
C
30,25
l
b
Weight
152