Professional Documents
Culture Documents
HS
Pumped liquids
Features and benefits Pumped liquids 33
Pumped Liquid Guide 33
Performance range
HS 2-pole 6 Electrical data
HS 4-pole 7 2-pole motors 34
HS 6-pole 8 4-pole motors 34
6-pole motors 35
Product range
HS single-stage, standard, 2-pole 10 Curve charts and technical data
HS single-stage, standard, 4-pole 11 How to read the curve charts 36
HS single-stage, extended, 4-pole 12 Curve conditions 37
HS single-stage, extended, 6-pole 13 Performance tests 37
HS two-stage, 4-pole 14 Certificates 37
HS two-stage, 6-pole 14
Performance curves
Identification Technical data
Nameplate 15
2-pole 38
Type key 15
4-pole 48
Mechanical shaft seals 16
6-pole 126
Stuffing boxes 16
Installation
Reference 28
System types 28
Location 28
Mechanical installation 28
Piping 29
2
Introduction HS
Horizontal split case pumps have horizontal pump shaft, Please note that for HS we use the following nomencla-
and the pump housing can be dismantled in the horizontal ture:
plane along the drive shaft.
Type: HS
The Grundfos horizontal split case pump, type HS, is
available in two main designs: Single-stage and two- Model: A, B, C ...
stage.
Design: single-stage, two-stage
The pumps are non-self-priming, centrifugal volute
pumps with radial suction and radial discharge port. Version: standard, extended, through-bore, non-
through-bore
The split-case construction enables removal and dis-
mantling of the internal pump parts - e.g. bearings, Variant: pump with motor and base frame, bare shaft
wear rings, impeller and shaft seal without disturbing pump
the motor or pipework.
3
Applications HS
Irrigation
Irrigation covers these applications:
• field irrigation (flooding)
• sprinkler irrigation
• drip-feed irrigation.
GR 2910
4
Features and benefits HS
5
Performance range HS
Grundfos HS pumps are available with 2-, 4- or 6-pole 1. Go into the relevant performance range chart.
motors. 2. Find your duty point.
The next three pages show the performance range cov- 3. Note which pump type covers your duty point.
ered by these three motor types. 4. First go to section “Product range” and then to
“Performance curves and technical data” and find
Knowing your required duty point, use the performance
more detailed information on your chosen pump.
ranges like this:
HS 2-pole
400
Q [m³/h]
90 Q [l/s]
2-pole, 50 Hz
HS
300
0
80
-30
00
5-1
250
12
70
60
150-100-240
200
50
100-80-240
150
40
30
100
80
20
60
50
100-80-300
80-65-240
40
10
9
30
8
25
7
6
20
150
120
100
80
60
50
40
30
20
[m]
H
1000
900
800
700
600
500
400
300
200
p
6
p H
[kPa] [m] HS
2000 4-pole, 50 Hz
200 HS 4-pole
250-200-580-2
350-300-770
150 200-150-480-2
300-250-680
200-150-460-2
120
450-350-660
150-125-420-2
1000 100 350-300-590
250-200-580
800 80
700 125-100-360-2
450-350-540
200-150-480
600 60 250-200-480 300-250-510
500 50
Performance range
350-300-480
150 300-250-380 30
400 40 -12
5-3
0 -2
50
80 25 - 42
80-50-380 0 -2 0
200-150-380 00
100-80-380 -3
80
300 30 450-350-440
12
5-1
00
100-80-300
-38
0 20 250-200-300
0-
1 50 350-350-390
125-100-300 15 -3
0-1 00
200 20 25 150-125-300
-29
0
250-250-300 350-300-340
15
80-65-240
15
200-150-240
0-
12 5-
100-80-240 150-100-240
24
250-250-240
0
100 10
80 8
70
60 6
20 30 40 50 60 80 100 150 200 300 400 500 600 800 1000 1500 2000 3000 4000
Q [m³/h]
6 7 8 9 10 20 30 40 50 60 70 80 100 200 300 400 500 600 Q [l/s]
7
8
p H
[kPa] [m] HS
1000 100 6-pole, 50 Hz
250-200-580-2
HS 6-pole
800 80
350-300-770
600 60 300-250-680
200-150-480-2
500 50
250-200-580
450-350-660
350-300-590
400 40
300-250-510
300 30
450-350-540
Performance range
350-300-480
200 20
300-250-420
15
450-350-440
350-300-340
350-350-390
100 10
80 8
60
50 5
60 80 100 150 200 300 400 500 600 800 1000 1500 2000 3000
Q [m³/h]
17 20 30 40 50 60 70 80 90 100 200 300 400 500 600 Q [l/s]
9
Product range HS
The tables on the following pages show the complete HS HS single-stage, standard, 2-pole
product range. The product range includes the pumps es-
tablished in WebCAPS.
Rated pressure PN 16
The range has been combined on the basis of the follow-
ing parameters: Pump housing Cast iron
• Rated pressure, i.e. PN. Impeller Construction: Double-suction
• Pump housing material. Material: Bronze
• Impeller construction and material. Coupling Pin and bush
• Coupling type. Shaft seal BBQV
• Shaft seal type. Flange BS (British standard)
• Flange type. Electricity supply 3 x 380 - 415 V 50 Hz
• Motor data, i.e. electricity supply and P2.
Motors with power rating up to and including 600 kW Single-stage, standard, Standard
2-pole pump motor
are available for "low voltage" applications.
P2
To a great extent the pumps can be adapted to the re- Pump size
[KW]
quirements of the individual customer. For customized so- 11
lutions, contact your local Grundfos company. 15
80-65-240 18.5
22
30
15
18.5
22
100-80-240
30
37
45
22
30
100-80-300 37
45
55
30
37
125-100-300 45
55
75
30
37
150-100-240 45
55
75
10
Product range HS
11
Product range HS
12
Product range HS
13
Product range HS
14
Identification HS
2 1 3 4 5 6
Type range
Nominal diameter
of suction port
HS 80-65-240 / 220 1/1 F A BBQV 1
Nominal diameter
of discharge port
A 96XXXXXX P2 01 27 0001
8 10
Nominal impeller diameter
180 57 2900
Actual impeller diameter
16/80 Pump version:
15
Identification HS
The following table explains the positions (1), (2), (3) and
(4).
16
Construction HS
Versions
Grundfos HS horizontal split case pumps are available
in four different main versions:
Version Description/characteristics
• single-stage
Standard
• in-line construction
• suction and/or discharge port sizes from DN 50
to 300 mm
• flow rate from 10 to 1000 m3/h
• fitted with inserts and bellows shaft seals
• shaft seals mounted on the inside of the inserts.
Extended • single-stage
• in-line construction
• suction and/or discharge port sizes from DN
200 to 450 mm
• flow rate from 400 to 3600 m3/h
• fitted with inserts and cartridge shaft seals
• shaft seals mounted on the outside of the
TM03 4028 1406
inserts
• fitted with external bearing housings
• extended versions have longer shaft than the
standard versions.
Through-bore • two-stage
• non-in-line (asymmetric) construction
• suction and/or discharge port sizes from DN
150 to 250 mm
• flow rate from 150 to 800 m3/h
• fitted with inserts and cartridge shaft seals
• shaft seals mounted on the outside of the
TM03 4026 1406
inserts
• internal pump housing diameter at wear rings
and at inserts are almost identical - therefore
the designation through-bore.
Non-through-bore
Non-through- • two-stage
• non-in-line (asymmetric) construction
• suction and/or discharge port sizes from DN
100 to 200 mm
• flow rate from 50 to 400 m3/h
• not fitted with inserts, but with bellows shaft
seals
TM03 1876 3305
17
Construction HS
HS single-stage, standard
Sectional view
18
Construction HS
HS single-stage, extended
Sectional view
19
Construction HS
HS two-stage, through-bore
Sectional view
20
Construction HS
HS two-stage, non-through-bore
Sectional view
21
Construction HS
These pos. nos. refer to pumps with stuffing box instead of mechanical shaft seal:
106 Gland Cast iron
106 a Screw Steel
107 Packing ring -
108 Distribution ring Bronze
22
Construction HS
Mechanical construction
Pump housing Bearings
The cast iron volute pump housing has radial suction HS pumps are fitted with two standard single-row deep-
port and radial discharge port. groove ball bearings. The bearings are of the open type
permitting the bearings to be relubricated. The bearings
The single-stage pumps are of the inline (symmetric)
are lubricated by Grundfos prior to delivery.
design, whereas the two-stage pumps have asymmet-
ric design. Inserts
All HS pumps, except two-stage, non-through-bore ver-
sions, have two inserts (pos. 124), one at the drive end
and one at the non-drive end of the pump shaft.
An insert has several functions:
Impeller
TM03 3814 1106
23
Construction HS
Coupling
HS pumps are fitted with a standard pin and bush cou- Fig. 21 Cartridge shaft seal type E
pling. Stuffing box
The coupling consists of two steel flanges connected by a Stuffing boxes are available with pure packing rings or
number of steel pins covered by rubber bushes. with packing rings with graphite seals.
Due to the coupling design, the rotating assembly of HS
pumps can be removed and serviced without dismantling
the motor from the base frame.
A 4 3
2
TM03 3755 0906
24
Construction HS
Base frame
Pump and motor are mounted on a common base frame
in the form of a welded, steel C-channel profile.
Surface treatment
All stationary cast iron parts have been
• primed with a high-build, non-toxic zink phosphate
coating; coating thickness is 50μm
• undercoated with a high-build, non-toxic, syntheti-
cally modified alkyd coating; coating thickness is
25μm.
Prior to delivery to the customer, pump, motor and base
frame are given a non-toxic, single-pack phenolic DCO
modified alkyd top coating; coating thickness is 25 μm.
Tropical protection
Grundfos offers HS pumps with extra surface treatment
for low-temperature applications (such as air condition-
ing) in environments with high humidity. In such envi-
ronments corrosion is a special problem.
Test pressure
Pressure testing is made with water
• at +20°C
• containing corrosion inhibitor.
The standard hydrostatic test pressure is 1.5 times pres-
sure against “closed valve” or “shut off” pressure. Howev-
er, this may vary from one HS to another. See table below.
Operating
Test pressure
Rated pressure pressure
bar MPa bar MPa
PN 16 16 1.6 24 2.4
PN 25 (standard) 20.7 2.07 31 3.1
PN 25 (extended
25 2.5 37.5 3.75
and two-stage)
25
Operating conditions HS
50
NBR (xxxP)
20 25 30 35 40 45 50 55 60 65 70 75 80
t [°C] NBR (nitrile) rubber covers a wide range of liquids at
1000 2250 3500 m temperatures below +100°C.
• Good mechanical properties
Fig. 24 Relationship between motor output (P2) and am-
• Resistant to water up to +80°C
bient temperature
• Resistant to diesel oil, various mineral oils, grease
Example: and vegetable oils
Fig. 24 shows that the load of the motor must be • Resistant to weak acids and alkalis
reduced to 88% when installed 3500 m above sea level. • Not resistant to polar solvents (alcohols, ketones
At an ambient temperature of 70°C the load of the and esters)
motor must be reduced to 78% of the rated output. • Not resistant to ozone and weather.
26
Operating conditions HS
27
Installation HS
Expansion joints
Expansion joints offer these advantages:
• They absorb thermal expansion and contraction of
pipework caused by variations in liquid temperature.
• They reduce mechanical influences in connection
with pressure surges in the pipework.
• Rubber bellows expansion joints isolate structure-
borne noise in the pipework.
Note: Do not fit expansion joints to make up for inac-
curacy in the pipework, e.g. centre displacement or
misalignment of flanges.
28
Installation HS
Turbulent flow
TM03 2542 4505
29
Installation HS
Discharge piping
1
TM03 2590 1109
Concentric
reducer
TM03 2538 4505
Eccentric
reducer
30
Selection of product HS
31
Selection of product HS
WebCAPS
WebCAPS is a Web-based Computer Aided Product
Selection program.
WebCAPS is accessible on Grundfos’ homepage,
www.grundfos.com, and offers
WebCAPS_English
Fig. 34 WebCAPS
32
Pumped liquids HS
33
Electrical data HS
2-pole motors
I
P2 Frame Standard voltage I 1/1
Cos ϕ 1/1 η start
[kW] size [V] [%]
------------
-
[A] I1 ⁄ 1
4-pole motors
I start
P2 Frame Standard voltage I 1/1
Cos ϕ 1/1 η
[kW] size [V] [%]
-------------
[A] I
1⁄1
2.2 100 380-415 5.05-4.60 0.81-0.82 82.0-81.0 6.7-6.7
3 100 380-415 6.80-6.15 0.82-0.83 82.5-82.0 7.4-7.4
4 112 380-415 8.80-8.00 0.82-0.83 84.5-84.0 7.1-7.1
5.5 132 380-415 11.8-10.8 0.83-0.84 86.0-86.0 6.6-6.6
7.5 132 380-415 15.4-14.2 0.84-0.84 88.0-88.0 6.8-6.8
11 160 380-415 21.5-19.6 0.88-0.88 89.0-89.0 7.3-7.3
15 160 380-415 29.0-26.5 0.87-0.87 90.0-90.0 7.2-7.2
18.5 180 380-415 36.0-33.0 0.86-0.86 91.0-91.0 6.8-6.8
22 180 380-415 42.0-38.5 0.87-0.87 91.0-91.0 7-7
30 200 380-415 57.5-52.5 0.87-0.87 91.5-91.5 6.9-6.9 If you require information about motors
not specified in the table, please
37 225 380-415 71.0-65.0 0.87-0.87 91.7-91.7 7-6.9
contact Grundfos.
45 225 380-415 85.5-78.5 0.87-0.87 92.4-92.4 6.5-6.5
55 250 380-415 104-95.5 0.87-0.87 92.4-92.4 6.5-6.5
75 250 380-415 140-128 0.88-0.88 93.0-93.0 6.7-6.7.
90 280 380-415 168-154 0.88-0.88 93.0-93.0 6.7-6.7
110 280 380-415 205-188 0.88-0.88 93.0-93.0 6.3-6.3
132 315 380-415 240-220 0.89-0.89 93.6-93.6 6.5-6.5
160 315 380-415 290-265 0.90-0.90 93.6-94.0 6.5-6.5
200 315 380-415 365-320 0.90-0.90 93.6-96.0 6.5-6.5
250 315CB 380-415 440-400 0.90-0.91 96.4-96.0 6.4-6.4
315 315CB 380-415 550-500 0.90-0.91 96.4-96.0 6-6
34
Electrical data HS
6-pole motors
I
P2 Frame Standard voltage I 1/1
Cos ϕ 1/1 η start
size [V] [%]
------------
-
[kW] [A] I
1⁄1
2.2 112 380-415 5.65-5.35 0.73-0.71 81.6-81.4 6-6.5
3 132 380-415 6.95-6.35 0.79-0.79 83.3-83.3 6.4-6.3
4 132 380-415 9.55-8.75 0.76-0.76 83.3-83.3 6.3-6.3
5.5 132 380-415 12.4-11.4 0.79-0.79 84.8-84.8 6.6-7
7.5 160 380-415 16.4-15.0 0.81-0.81 86.0-86.0 6.3-6.3
11 160 380-415 23.0-21.0 0.83-0.83 88.5-88.5 6.8-6.9
15 180 380-415 30.0-27.5 0.86-0.86 89.5-89.5 7-6.9
18.5 200 380-415 36.5-33.5 0.85-0.85 91.0-91.0 6.8-6.7
22 200 380-415 43.5-39.5 0.84-0.84 92.0-92.0 6.8-6.8 If you require information about motors
not specified in the table, please
30 225 380-415 61.5-56.5 0.82-0.82 91.0-91.0 6.4-6.4
contact Grundfos.
37 250 380-415 74.5-68.0 0.83-0.83 91.7-91.7 6.5-6.5
45 250 380-415 88.0-80.5 0.84-0.84 92.4-92.4 6.3-6.3
55 280 380-415 108-98.5 0.84-0.84 92.4-92.4 6.3-6.3
75 280 380-415 144-132 0.86-0.86 93.0-93.0 6.5-6.5
90 315 380-415 172-158 0.86-0.86 93.0-93.0 6.5-6.5
110 315 380-415 210-192 0.86-0.86 93.0-93.0 6.2-6.2.
132 315 380-415 250-230 0.86-0.86 93.6-93.6 6.2-6.2
160 315 380-415 295-270 0.87-0.86 95.2-96.0 6-6
200 315 380-415 360-335 0.88-0.86 96.2-96.0 6-6
35
Curve charts and HS
technical data
The following many pages are divided into sections:
Size of impeller
H
[m]
85
HS 80-65-240
Total pump head ø240 50 Hz, n = 2900 min-1
H = Htotal 80 ISO 9906 Grade 2
Pump type and speed
of motor [min -1]
75
70
ø220
65 QH curve for the indi-
vidual pump.
60 The bold curve indicates
the recommended
ø200 performance range.
55
50
45 ø180
40
35
30 NPSH
[m]
25 10
20 8
15 6
The NPSH curve is an
10 4 average curve for all
variants shown. When
sizing the pumps, add a
5 NPSH 2 safety margin of at least
0.5 m.
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 Q [m³/h]
P2 Eta
[kW] [%]
40 80 The eta curves show
the efficiency of the
35 70 pumps shown
ø240
30 ø220 ø240 60
ø180 ø200
25 50
ø220
20 40 The power curves
indicate pump input
15 ø200 30 power [P 2] for the
ø180 pumps shown
10 20
TM03 2844 5005
5 10
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 Q [m³/h]
36
Curve charts and HS
technical data
Curve conditions Performance tests
The guidelines below apply to the curves shown in the The requested duty point for every pump is tested
performance charts on page 38 to page 152. according to ISO 9906, Grade 2, and without certifica-
tion.
• Tolerances according to: ISO 9906, Grade 2.
• The curves show pump performance with different In case of pumps ordered on the basis of impeller diam-
impeller diameters at the nominal speed. eter only (no requested duty point), the pump will be
• The bold part of the curves show the recom- tested at a duty point which is 2/3 of the maximum flow
mended operating range. of the published performance curve which is related to
• Do not operate the pump along the thin parts of the the ordered impeller diameter (according to ISO 9906,
curves. If your duty point lies here, you should se- Grade 2).
lect a smaller or larger pump type. If the customer requires either more points on the curve
• Do not use the pumps at minimum flows below to be checked or certain minimum performances or cer-
0.3 x Q at optimum efficiency because of the risk of tificates, individual measurements must be made, and
overheating of the pump. a certificate can be ordered.
• The curves apply to the pumping of airless water at
a temperature of +20°C and a kinematic viscosity of Certificates
1 mm2/s (1 cSt).
Certificates have to be confirmed for every order and
• ETA: The lines show values of the hydraulic effi-
are available on request as follows:
ciency of the pump for the different impeller diame-
ters. • Certificate of compliance with the order (EN 10204 -
• NPSH: The curves show average values measured 2.1)
under the same conditions as the performance • Pump test sheet.
curves.
When dimensioning the pump, add a safety margin
of at least 0.5 m.
• In case of other densities than 1000 kg/m3 the dis-
charge pressure is proportional to the density.
• When pumping liquids with a density higher than
1000 kg/m3, motors with correspondingly higher
outputs must be used.
37
Performance curves HS 80-65-240
2-pole
Technical data
2-pole
H
[m]
85
HS 80-65-240
ø240 50 Hz, n = 2900 min-1
80 ISO 9906 Grade 2
75
70
ø220
65
60
ø200
55
50
45 ø180
40
35
30 NPSH
[m]
25 10
20 8
15 6
10 4
5 NPSH 2
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 Q [m³/h]
P2 Eta
[kW] [%]
40 80
35 70
ø240
30 ø220 ø240 60
ø180 ø200
25 50
ø220
20 40
15 ø200 30
ø180
10 20
5 10
TM03 2844 5005
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 Q [m³/h]
38
Technical data HS 80-65-240
2-pole
Dimensional sketches
HS standard, 80-65-240
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
39
Performance curves HS 100-80-240
2-pole
H
[m]
80
HS 100-80-240
ø235 50 Hz, n = 2900 min-1
75 ISO 9906 Grade 2
70
ø220
65
60
ø205
55
50 ø190
45
ø175
40
35
30
25 NPSH
[m]
20 16
15 12
10 8
5 4
NPSH
0 0
0 20 40 60 80 100 120 140 160 180 200 Q [m³/h]
P2 Eta
[kW] [%]
45 80
ø205 ø235
40 ø175 ø220 ø235 70
ø190
35 60
ø220
30 50
25 ø205 40
20 ø190 30
15 20
ø175
10 10
TM03 2845 5005
5 0
0 20 40 60 80 100 120 140 160 180 200 Q [m³/h]
40
Technical data HS 100-80-240
2-pole
Dimensional sketch
HS standard, 100-80-240
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
41
Performance curves HS 100-80-300
2-pole
H
[m]
125
ø295 HS 100-80-300
50 Hz, n = 2900 min-1
120 ISO 9906 Grade 2
115
ø280
110
105
100
ø260
95
90
85 ø240
80
75
70
ø215
65
60
55 NPSH
[m]
50 12
45 8
40 4
NPSH
35 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Q [m³/h]
P2 Eta
[kW] [%]
80 80
ø215
ø240 ø260
70 ø280 70
ø295
60 60
ø295
50 ø280 50
ø260
40 40
ø240
30 30
ø215
20 20
10 10
TM03 2846 5005
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Q [m³/h]
42
Technical data HS 100-80-300
2-pole
Dimensional sketch
HS standard, 100-80-300
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
43
Performance curves HS 125-100-300
2-pole
H
[m]
105
ø265
HS 125-100-300
50 Hz, n = 2900 min-1
100 ø260
ISO 9906 Grade 2
95
ø250
90
85 ø240
80
ø230
75
70
65
60
55
50
45
40
35
30
25
NPSH
[m]
20 12
15 8
10 NPSH 4
5 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [m³/h]
P2 Eta
[kW] [%]
160 80
140 70
120 60
100 50
20 10
TM03 2848 5005
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [m³/h]
44
Technical data HS 125-100-300
2-pole
Dimensional sketch
HS standard, 125-100-300
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
45
Performance curves HS 150-100-240
2-pole
H
[m]
HS 150-100-240
85
50 Hz, n = 2900 min-1
ISO 9906 Grade 2
80 ø245
ø240
75
70
ø230
65
ø220
60
ø210
55
ø200
50
ø190
45
40 NPSH
[m]
35 ø245 (NPSH) 16
30 12
ø220 (NPSH)
25 ø190 (NPSH) 8
20 4
15 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 Q [m³/h]
P2 Eta
[kW] [%]
80 ø245 80
ø220 ø240
70 ø190 ø200 ø210 ø230 70
ø245
60 ø240 60
50 ø230 50
40 ø220 40
ø210
30 ø200 30
ø190
20 20
10 10
TM03 2847 5005
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 Q [m³/h]
46
Technical data HS 150-100-240
2-pole
Dimensional sketch
HS standard, 150-100-240
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
47
Performance curves HS 80-50-380
4-pole
4-pole
H
[m]
HS 80-50-380
50 ø370 50 Hz, n = 1450 min-1
ISO 9906 Grade 2
45
ø340
40
35 ø310
30
ø280
25
ø250
20
NPSH
[m]
15 3
5 1
0 0
0 10 20 30 40 50 60 70 80 90Q [m³/h]
P2 Eta
[kW] [%]
14 70
ø340
ø370
12 ø310 60
ø280
ø250
ø370
10 50
ø340
8 40
ø310
6 30
ø280
4 ø250 20
2 10
TM03 2805 5005
0 0
0 10 20 30 40 50 60 70 80 90Q [m³/h]
48
Technical data HS 80-50-380
4-pole
Dimensional sketch
HS standard, 80-50-380
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
49
Performance curves HS 80-65-240
4-pole
H
[m]
HS 80-65-240
22 50 Hz, n = 1450 min-1
ISO 9906 Grade 2
ø240
20
18
ø220
16
14 ø200
12
ø180
10
8
NPSH
[m]
6 3
NPSH
4 2
2 1
0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]
P2 Eta
[kW] [%]
7 70
6 60
ø180 ø240
ø200 ø220
5 50
4 ø240 40
3 30
ø220
2 ø200 20
ø180
1 10
TM03 2806 5005
0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]
50
Technical data HS 80-65-240
4-pole
Dimensional sketch
HS standard, 80-65-240
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
51
Performance curves HS 100-80-240
4-pole
H
[m]
HS 100-80-240
22 50 Hz, n = 1450 min-1
ISO 9906 Grade 2
20
ø235
18
ø220
16
ø205
14
ø190
12
ø175
10
NPSH
[m]
8 8
6 6
4 4
2 2
NPSH
0 0
0 10 20 30 40 50 60 70 80 90 100 Q [m³/h]
P2 Eta
[kW] [%]
8 80
7 70
ø175 ø190 ø205 ø220 ø235
6 60
5 ø235 50
4 ø220 40
ø205
3 30
ø190
2 20
ø175
1 10
TM03 2807 5005
0 0
0 10 20 30 40 50 60 70 80 90 100 Q [m³/h]
52
Technical data HS 100-80-240
4-pole
Dimensional sketch
HS standard, 100-80-240
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
53
Performance curves HS 100-80-300
4-pole
H
[m]
HS 100-80-300
32 ø295 50 Hz, n = 1450 min-1
ISO 9906 Grade 2
30
ø280
28
26
ø260
24
22
ø240
20
18
ø215
16
NPSH
[m]
14 3
12 2
10 1
NPSH
8 0
0 10 20 30 40 50 60 70 80 Q [m³/h]
P2 Eta
[kW] [%]
ø240 ø260 ø280
ø295
7 70
ø280
6 60
ø215
ø295 ø260
5 50
ø240
4 40
3 ø215 30
2 20
1 10
TM03 2808 5005
0 0
0 10 20 30 40 50 60 70 80 Q [m³/h]
54
Technical data HS 100-80-300
4-pole
Dimensional sketch
HS standard, 100-80-300
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
55
Performance curves HS 100-80-380
4-pole
H
[m]
HS 100-80-380
55 50 Hz, n = 1450 min-1
ø395
ISO 9906 Grade 2
50 ø380
45 ø360
40 ø340
35 ø320
ø300
30
ø280
25
ø250
20
NPSH
[m]
15 12
10 8
5 4
NPSH
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [m³/h]
P2 Eta
[kW] [%]
28 70
ø395
ø250
24 ø360 ø380 60
ø300 ø340
ø280
ø320
20 50
ø395
ø380
16 40
ø360
12 ø340 30
ø320
8 ø300 20
ø280
4 ø250 10
TM03 2809 5005
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [m³/h]
56
Technical data HS 100-80-380
4-pole
Dimensional sketch
HS standard, 100-80-380
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
57
Performance curves HS 125-100-300
4-pole
H
[m]
HS 125-100-300
50 Hz, n = 1450 min-1
36
ISO 9906 Grade 2
ø302
32
ø290
28
ø270
24
ø250
20
ø230
16
12
NPSH
[m]
8 ø302 (NPSH) 8
ø270 (NPSH)
4 4
ø230 (NPSH)
0 0
0 20 40 60 80 100 120 140 160 Q [m³/h]
P2 Eta
[kW] [%]
16 80
14 70
ø302
ø230
12 60
ø250 ø290
10 ø302 50
ø270 ø290
8 ø270 40
6 ø250 30
ø230
4 20
2 10
TM03 2811 5005
0 0
0 20 40 60 80 100 120 140 160 Q [m³/h]
58
Technical data HS 125-100-300
4-pole
Dimensional sketch
HS standard, 125-100-300
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
59
Performance curves HS 125-100-360-2
4-pole
H
[m]
HS 125-100-360-2
110 50 Hz, n = 1450 min-1
ISO 9906 Grade 2
ø370
100
90
80
70
60
ø278
50
NPSH
[m]
40 8
30 ø370 (NPSH) 6
ø278 (NPSH)
20 4
10 2
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 Q [m³/h]
P2 Eta
[kW] [%]
80 80
ø370
70 70
ø370
ø278
60 60
50 50
40 40
30 ø278 30
20 20
10 10
TM03 2841 5005
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 Q [m³/h]
60
Technical data HS 125-100-360-2
4-pole
Dimensional sketch
HS two-stage non-through-bore, 125-100-360-2
61
Performance curves HS 125-100-380
4-pole
H
[m]
HS 125-100-380
50 50 Hz, n = 1450 min-1
ISO 9906 Grade 2
ø370
45 ø360
40 ø340
ø320
35
ø300
30
ø280
ø270
25
20
NPSH
[m]
15 12
10 8
5 4
NPSH
0 0
0 20 40 60 80 100 120 140 160 180 200 Q [m³/h]
P2 Eta
[kW] [%]
32 ø340 80
ø360
ø320
28 70
ø270 ø370
24 60
ø280 ø300 ø370
ø360
20 50
ø340
ø300
16 40
ø320
12 ø280 30
ø270
8 20
4 10
TM03 2812 5005
0 0
0 20 40 60 80 100 120 140 160 180 200 Q [m³/h]
62
Technical data HS 125-100-380
4-pole
Dimensional sketch
HS standard, 125-100-380
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
63
Performance curves HS 150-100-240
4-pole
H
[m]
HS 150-100-240
20 ø245 50 Hz, n = 1450 min-1
ISO 9906 Grade 2
ø240
18 ø230
ø220
16
ø210
14
ø200
12
ø190
10
8
NPSH
[m]
6 12
ø245 (NPSH)
4 8
ø220 (NPSH)
2 4
ø190 (NPSH)
0 0
0 20 40 60 80 100 120 140 160 180 Q [m³/h]
P2 Eta
[kW] [%]
16 80
14 ø245 70
ø230 ø240
ø200 ø210
12 ø220 60
ø190
10 50
ø245
8 ø240 40
ø230
6 30
ø220
ø210
4 ø200 20
ø190
2 10
TM03 2810 5005
0 0
0 20 40 60 80 100 120 140 160 180 Q [m³/h]
64
Technical data HS 150-100-240
4-pole
Dimensional sketch
HS standard, 150-100-240
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
65
Performance curves HS 150-125-240
4-pole
H
[m]
HS 150-125-240
22 50 Hz, n = 1450 min-1
ISO 9906 Grade 2
ø245
20
18 ø230
16
ø215
14
ø200
12
ø185
10
8
NPSH
[m]
6 6
4 4
2 2
NPSH
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 Q [m³/h]
P2 Eta
[kW] [%]
16 80
ø245
10 50
8 40
ø230
6 ø215 30
ø200
4 20
ø185
2 10
TM03 2813 5005
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 Q [m³/h]
66
Technical data HS 150-125-240
4-pole
Dimensional sketch
HS standard, 150-125-240
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
67
Performance curves HS 150-125-290
4-pole
H
[m] ø286 HS 150-125-290
28
ø280 50 Hz, n = 1450 min-1
ISO 9906 Grade 2
26
24 ø260
22
20 ø240
18
ø220
16
ø210
14
12 NPSH
[m]
10 10
8 8
6 6
4 4
2 NPSH 2
0 0
0 20 40 60 80 100 120 140 160 180 200 220 Q [m³/h]
P2 Eta
[kW] [%]
32 80
ø286
28 ø280 70
ø220
ø240 ø260
24 ø210 60
20 50
16 ø286 40
ø280
12 ø260 30
ø240
8 20
ø220
ø210
4 10
TM03 2814 5005
0 0
0 20 40 60 80 100 120 140 160 180 200 220 Q [m³/h]
68
Technical data HS 150-125-290
4-pole
Dimensional sketch
HS standard, 150-125-290
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
69
Performance curves HS 150-125-300
4-pole
H
[m]
34
HS 150-125-300
ø303
50 Hz, n = 1450 min-1
32 ISO 9906 Grade 2
ø290
30
28
ø270
26
24
ø250
22
20
ø230
18
16
14
12
10
8 NPSH
[m]
6 ø 303 (NPSH) 6
ø250 (NPSH)
4 4
2 ø230 (NPSH) 2
0 0
0 40 80 120 160 200 240 280 320 360 Q [m³/h]
P2 Eta
[kW] [%]
40 80
35 70
ø303
30 ø270 60
ø250 ø290
ø230 ø303
25 50
ø290
20 40
ø270
15 30
ø250
10 20
ø230
5 10
TM03 2815 5005
0 0
0 40 80 120 160 200 240 280 320 360 Q [m³/h]
70
Technical data HS 150-125-300
4-pole
Dimensional sketch
HS standard, 150-125-300
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
71
Performance curves HS 150-125-380
4-pole
H
[m]
HS 150-125-380
52
ø380 50 Hz, n = 1450 min-1
ISO 9906 Grade 2
48
ø360
44
ø340
40
36 ø320
32 ø300
28
ø280
24
20
16
NPSH
[m]
12 ø340 (NPSH) 3
ø300 (NPSH)
ø380 (NPSH)
8 ø280 (NPSH) 2
4 1
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 Q [m³/h]
P2 Eta
[kW] [%]
80 80
70 70
60 60
ø380
ø340 ø360
50 ø300 ø320 50
ø280
40 40
ø380
30 30
ø360
ø340
20 ø320 20
ø300
ø280
10 10
TM03 2816 5005
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 Q [m³/h]
72
Technical data HS 150-125-380
4-pole
Dimensional sketch
HS standard, 150-125-380
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
73
Performance curves HS 150-125-420-2
4-pole
H
[m]
HS 150-125-420-2
130
50 Hz, n = 1450 min-1
ISO 9906 Grade 2
ø410
120
110
100
90
80
70 ø310
60
50
NPSH
[m]
40 8
ø410 (NPSH)
30 ø310 (NPSH) 6
20 4
10 2
0 0
0 40 80 120 160 200 240 280 320 Q [m³/h]
P2 Eta
[kW] [%]
160 80
140 70
ø410
120 60
ø310 ø410
100 50
80 40
60 30
ø310
40 20
20 10
TM03 2842 5005
0 0
0 40 80 120 160 200 240 280 320 Q [m³/h]
74
Technical data HS 150-125-420-2
4-pole
Dimensional sketch
HS two-stage non-through-bore, 150-125-420-2
75
Performance curves HS 200-150-240
4-pole
H
[m]
HS 200-150-240
22 ø252 50 Hz, n = 1450 min-1
ISO 9906 Grade 2
20 ø240
18
ø220
16
ø205
14
12
10
NPSH
[m]
8 ø230 (NPSH) 8
6 6
4 4
ø205 (NPSH) ø252 (NPSH)
2 2
0 0
0 40 80 120 160 200 240 280 320 360 Q [m³/h]
P2 Eta
[kW] [%]
32 80
ø252
28 70
ø205 ø220 ø240
24 60
20 50
ø252
16 40
ø240
12 ø220 30
ø205
8 20
4 10
TM03 2817 5005
0 0
0 40 80 120 160 200 240 280 320 360 Q [m³/h]
76
Technical data HS 200-150-240
4-pole
Dimensional sketch
HS standard, 200-150-240
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
77
Performance curves HS 200-150-300
4-pole
H
[m]
36 ø325 HS 200-150-300
50 Hz, n = 1450 min-1
34 ISO 9906 Grade 2
32
ø300
30
28
ø280
26
24
ø260
22
20
ø240
18
16
14
12 NPSH
[m]
10 5
8 4
6 3
4 2
NPSH
2 1
0 0
0 40 80 120 160 200 240 280 320 360 400 440 Q [m³/h]
P2 Eta
[kW] [%]
40 80
35 ø300 ø325 70
ø260 ø280
ø240 ø325
30 60
25 ø300 50
ø280
20 40
ø260
15 30
ø240
10 20
5 10
TM03 2818 5005
0 0
0 40 80 120 160 200 240 280 320 360 400 440 Q [m³/h]
78
Technical data HS 200-150-300
4-pole
Dimensional sketch
HS standard, 200-150-300
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
79
Performance curves HS 200-150-380
4-pole
H
[m]
ø375 HS 200-150-380
48 50 Hz, n = 1450 min-1
ISO 9906 Grade 2
ø360
44
ø340
40
36 ø320
32 ø300
28 ø280
24
NPSH
[m]
20 5
ø375 (NPSH)
16 4
12 3
8 2
ø280 (NPSH)
4 1
ø340 (NPSH)
0 0
0 40 80 120 160 200 240 280 320 360 400 440 Q [m³/h]
P2 Eta
[kW] [%]
80 ø375 80
ø340 ø360
ø320
ø300
70 ø280 70
60 60
ø375
50 ø360 50
40 ø340 40
ø320
30 30
ø300
20 ø280 20
10 10
TM03 2819 5005
0 0
0 40 80 120 160 200 240 280 320 360 400 440 Q [m³/h]
80
Technical data HS 200-150-380
4-pole
Dimensional sketch
HS standard, 200-150-380
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
81
Performance curves HS 200-150-440-2
4-pole
H
[m]
HS 200-150-440-2
150
50 Hz, n = 1450 min-1
ø442 ISO 9906 Grade 2
140
130
120
110
100
ø366
90
80
70
60
50
40 NPSH
[m]
30 ø442 (NPSH) 6
ø366 (NPSH)
20 4
10 2
0 0
0 40 80 120 160 200 240 280 320 360 400 Q [m³/h]
P2 Eta
[kW] [%]
320 80
280 70
ø366
240 ø442 60
200 50
ø442
160 40
120 30
ø366
80 20
40 10
TM03 2843 5005
0 0
0 40 80 120 160 200 240 280 320 360 400 Q [m³/h]
82
Technical data HS 200-150-440-2
4-pole
Dimensional sketch
HS two-stage non-through-bore, 200-150-440-2
83
Performance curves HS 200-150-480
4-pole
H
[m]
80
HS 200-150-480
ø475
50 Hz, n = 1450 min-1
75 ISO 9906 Grade 2
ø460
70
ø440
65
ø420
60
ø400
55
ø380
50
ø360
45
40
35
30
25 NPSH
[m]
20 8
ø475 (NPSH)
ø440 (NPSH)
15 6
ø400 (NPSH)
10 4
ø360 (NPSH)
5 2
0 0
0 50 100 150 200 250 300 350 400 450 500 550 Q [m³/h]
P2 Eta
[kW] [%]
160 80
ø460
140 70
ø475
120 ø420 ø440 ø475 60
ø380 ø400
ø360 ø460
100 50
ø440
80 ø420 40
ø400
60 ø380 30
ø360
40 20
20 10
TM03 2820 5005
0 0
0 50 100 150 200 250 300 350 400 450 500 550 Q [m³/h]
84
Technical data HS 200-150-480
4-pole
Dimensional sketch
HS standard, 200-150-480
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
85
Performance curves HS 200-150-480-2
4-pole
H
[m]
HS 200-150-480-2
170
50 Hz, n = 1450 min-1
ø475 ISO 9906 Grade 2
160
150
140
ø428
130
120
110
ø380
100
90
80
70 NPSH
[m]
60 16
50 12
ø380 (NPSH) ø475 (NPSH)
40 8
30 4
20 0
0 50 100 150 200 250 300 350 400 450 500 550 600 Q [m³/h]
P2 Eta
[kW] [%]
400 80
350 70
250 ø475 50
200 40
ø428
150 30
ø380
100 20
50 10
TM03 2839 5005
0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 Q [m³/h]
86
Technical data HS 200-150-480-2
4-pole
Dimensional sketch
HS two-stage through-bore, 200-150-480-2
87
Performance curves HS 250-200-300
4-pole
H
[m] ø340
40 HS 250-200-300
50 Hz, n = 1450 min-1
38
ISO 9906 Grade 2
36 ø320
34
32
ø300
30
28
ø280
26
24
ø260
22
20
ø235
18
16
NPSH
[m]
14 14
12 12
10 10
8 8
6 6
4 4
NPSH
2 2
0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 Q [m³/h]
P2 Eta
[kW] [%]
80 80
ø300
ø280
ø320 ø340
70 ø260 70
60 60
ø235 ø340
50 50
ø320
40 40
30 ø300 30
ø280
20 ø260 20
ø235
10 10
TM03 2821 5005
0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 Q [m³/h]
88
Technical data HS 250-200-300
4-pole
Dimensional sketch
HS standard, 250-200-300
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
89
Performance curves HS 250-200-380
4-pole
H
[m]
HS 250-200-380
52
50 Hz, n = 1450 min-1
ø378
ISO 9906 Grade 2
48
ø360
44
40 ø340
36
ø320
32
ø300
28
24
20
NPSH
[m]
16 8
12 6
8 4
4 NPSH 2
0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 Q [m³/h]
P2 Eta
[kW] [%]
100 90
90 80
80 ø340 ø378 70
ø320 ø360
ø300
70 ø378 60
60 ø360 50
50 ø340 40
40 30
ø320
30 ø300 20
20 10
TM03 2824 5005
10 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 Q [m³/h]
90
Technical data HS 250-200-380
4-pole
Dimensional sketch
HS standard, 250-200-380
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
91
Performance curves HS 250-200-480
4-pole
H
[m]
ø480 HS 250-200-480
80
50 Hz, n = 1450 min-1
ISO 9906 Grade 2
76
ø450
72
ø440
68
ø420
64
60
ø400
56
52 ø380
ø370
48
44 NPSH
[m]
40 10
36 8
32 6
28 4
NPSH
24 2
20 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 Q [m³/h]
P2 Eta
[kW] [%]
360 ø420 90
320 ø480 80
ø370 ø400
ø380 ø440 ø450
280 70
240 60
200 50
ø480
160 ø450 40
ø440
120 ø420 30
ø400
ø380
80 ø370 20
40 10
TM03 2822 5005
0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 Q [m³/h]
92
Technical data HS 250-200-480
4-pole
Dimensional sketch
HS standard, 250-200-480
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
93
Performance curves HS 250-200-580
4-pole
H
[m]
HS 250-200-580
130
50 Hz, n = 1450 min-1
ISO 9906 Grade 2
120 ø580
110
100
ø522
90
80
ø464
70
60
50
40
NPSH
[m]
30 12
ø580 (NPSH)
ø464 (NPSH)
20 8
10 4
0 0
0 100 200 300 400 500 600 700 800 900 1000 Q [m³/h]
P2 Eta
[kW] [%]
360 80
ø580
320 ø464 ø522 ø580 70
280 60
240 ø522 50
200 40
ø464
160 30
120 20
80 10
TM03 3957 1306
40 0
0 100 200 300 400 500 600 700 800 900 1000 Q [m³/h]
94
Technical data HS 250-200-580
4-pole
Dimensional sketch
HS extended, 250-200-580
95
Performance curves HS 250-200-580-2
4-pole
H
[m]
HS 250-200-580-2
ø575
240 50 Hz, n = 1450 min-1
ISO 9906 Grade 2
220
200
ø518
180
160
ø460
140
120
100
80
NPSH
[m]
60 12
ø518 (NPSH)
40 ø460 (NPSH) 8
ø575 (NPSH)
20 4
0 0
0 100 200 300 400 500 600 700 800 900 Q [m³/h]
P2 Eta
[kW] [%]
800 80
ø575
700 70
ø518
600 60
ø460
ø575
500 50
400 ø518 40
300 30
ø460
200 20
100 10
TM03 2840 5005
0 0
0 100 200 300 400 500 600 700 800 900 Q [m³/h]
96
Technical data HS 250-200-580-2
4-pole
Dimensional sketch
HS two-stage through-bore, 250-200-580-2
97
Performance curves HS 250-250-240
4-pole
H
[m]
HS 250-250-240
24
ø265 50 Hz, n = 1450 min-1
ISO 9906 Grade 2
ø260
22
ø250
20
18 ø236
16 ø222
14
12
10
NPSH
[m]
8 10
6 8
4 6
2 4
NPSH
0 2
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 Q [m³/h]
P2 Eta
[kW] [%]
45 90
40 80
ø265
35 ø250 ø260 70
ø236
30 ø222 60
ø265
ø260
25 50
ø250
20 40
ø236
15 ø222 30
10 20
5 10
TM03 2823 5005
0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 Q [m³/h]
98
Technical data HS 250-250-240
4-pole
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
99
Performance curves HS 250-250-300
4-pole
H
[m]
36
ø318 HS 250-250-300
50 Hz, n = 1450 min-1
34 ISO 9906 Grade 2
ø300
32
30
28 ø280
26
24
ø260
22
ø245
20
18
16
14
12
10
8 NPSH
[m]
ø318 (NPSH)
6 6
ø245 (NPSH)
4 4
ø280 (NPSH)
2 2
0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 Q [m³/h]
P2 Eta
[kW] [%]
90 90
80 80
70 70
ø245 ø260 ø280 ø300 ø318
60 60
ø318
50 ø300 50
40 40
ø280
30 ø260 30
ø245
20 20
10 10
TM03 2825 5005
0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850Q [m³/h]
100
Technical data HS 250-250-300
4-pole
Dimensional sketch
HS standard, 250-250-300
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
101
Performance curves HS 300-250-380
4-pole
H
[m]
HS 300-250-380
60 50 Hz, n = 1450 min-1
ø421
ISO 9906 Grade 2
55
ø400
50
ø380
45
ø360
40
ø340
35
ø320
30
25
20
NPSH
[m]
15 6
10 4
5 ø320 (NPSH) 2
ø360 (NPSH)
ø421 (NPSH)
0 0
0 100 200 300 400 500 600 700 800 900 1000 Q [m³/h]
P2 Eta
[kW] [%]
180 90
ø421
160 ø400 80
ø320 ø340 ø360 ø380
140 70
ø421
120 60
ø400
100 50
ø380
80 40
ø360
60 ø340 30
ø320
40 20
20 10
TM03 2826 5005
0 0
0 100 200 300 400 500 600 700 800 900 1000 Q [m³/h]
102
Technical data HS 300-250-380
4-pole
Dimensional sketch
HS standard, 300-250-380
For pumps with stuffing box the dimension in L1 and L2 should be added to the value in the column above.
103
Performance curves HS 300-250-420
4-pole
H
[m]
HS 300-250-420
60
ø415 50 Hz, n = 1450 min-1
ISO 9906 Grade 2
56
52
48
ø375
44
40
36 ø332
32
28
24
20 NPSH
[m]
16 8
12 ø332 (NPSH) 6
8 ø415 (NPSH) 4
4 2
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [m³/h]
P2 Eta
[kW] [%]
360 90
320 80
ø415
ø375
280 70
ø332
240 60
ø415
200 50
160 40
ø375
120 30
ø332
80 20
40 10
TM03 2828 5005
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600Q [m³/h]
104
Technical data HS 300-250-420
4-pole
Dimensional sketch
HS extended, 300-250-420
105
Performance curves HS 300-250-510
4-pole
H
[m]
100 HS 300-250-510
50 Hz, n = 1450 min-1
95 ø510 ISO 9906 Grade 2
90
85
80
ø480
75
70
65
ø410
60
55
50
45
40
35 NPSH
[m]
30 10
25 8
20 6
ø410 (NPSH)
15 ø510 (NPSH) 4
10 2
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [m³/h]
P2 Eta
[kW] [%]
450 90
400 ø510 80
350 ø480 70
ø410 ø510
300 60
250 ø480 50
200 40
ø410
150 30
100 20
50 10
TM03 2829 5005
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [m³/h]
106
Technical data HS 300-250-510
4-pole
Dimensional sketch
HS extended, 300-250-510
107
Performance curves HS 300-250-680
4-pole
H
[m]
170
HS 300-250-680
ø677 50 Hz, n = 1450 min-1
160 ISO 9906 Grade 2
150
140
ø609
130
120
110
ø542
100
90
80 NPSH
[m]
70 ø677 (NPSH) 24
60 20
ø542 (NPSH)
50 16
40 12
30 8
20 4
10 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [m³/h]
P2 Eta
[kW] [%]
900 80
800 ø677 70
ø609 ø677
ø542
700 60
600 50
ø609
500 40
ø542
400 30
300 20
200 10
TM03 2830 5005
100 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [m³/h]
108
Technical data HS 300-250-680
4-pole
Dimensional sketch
HS extended, 300-250-680
109
Performance curves HS 350-300-340
4-pole
H
[m]
36 HS 350-300-340
ø337
50 Hz, n = 1450 min-1
34 ISO 9906 Grade 2
32
30 ø313
28
26
ø290
24
22
20
18
16
14
12
10 NPSH
[m]
8 16
6 12
ø290 (NPSH) ø337 (NPSH)
4 8
ø313 (NPSH)
2 4
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [m³/h]
P2 Eta
[kW] [%]
180 90
160 80
140 70
ø337
120 60
ø313
ø290
100 50
80 ø337 40
60 ø313 30
ø290
40 20
20 10
TM03 2831 5005
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600Q [m³/h]
110
Technical data HS 350-300-340
4-pole
Dimensional sketch
HS extended, 350-300-340
111
Performance curves HS 350-300-480
4-pole
H
[m]
HS 350-300-480
80
50 Hz, n = 1450 min-1
ø475 ISO 9906 Grade 2
75
70
65
ø427
60
55
50
ø380
45
40
35
30 NPSH
[m]
25 12
ø427 (NPSH)
ø380 (NPSH) ø475 (NPSH)
20 8
15 4
10 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Q [m³/h]
P2 Eta
[kW] [%]
900 90
800 80
ø380 ø427 ø475
700 70
600 60
500 50
400 ø475 40
300 ø427 30
200 ø380 20
100 10
TM03 2832 5005
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Q [m³/h]
112
Technical data HS 350-300-480
4-pole
Dimensional sketch
HS extended, 350-300-480
113
Performance curves HS 350-300-590
4-pole
H
[m]
HS 350-300-590
130 50 Hz, n = 1450 min-1
ø585
ISO 9906 Grade 2
120
110
ø526
100
90
ø468
80
70
60
NPSH
[m]
50 16
40 ø526 (NPSH) 12
ø585 (NPSH)
ø468 (NPSH)
30 8
20 4
10 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [m³/h]
P2 Eta
[kW] [%]
900 90
800 80
ø585
ø468 ø526 ø585
700 70
600 60
ø526
500 50
400 40
ø468
300 30
200 20
100 10
TM03 2833 5005
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [m³/h]
114
Technical data HS 350-300-590
4-pole
Dimensional sketch
HS extended, 350-300-590
115
Performance curves HS 350-300-770
4-pole
H
[m]
220
HS 350-300-770
50 Hz, n = 1450 min-1
ø774
210 ISO 9906 Grade 2
200
190
180
ø697
170
160
150
140
ø619
130
120
110
100
90 NPSH
[m]
80 ø619 (NPSH) ø774 (NPSH) 12
70 8
60 4
50 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [m³/h]
P2 Eta
[kW] [%]
1800 80
1600 ø774 70
ø697
ø619
ø774
1400 60
1200 50
ø697
1000 40
800 ø619 30
600 20
400 10
TM03 2834 5005
200 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [m³/h]
116
Technical data HS 350-300-770
4-pole
Dimensional sketch
HS extended, 350-300-770
117
Performance curves HS 350-350-390
4-pole
H
[m]
HS 350-350-390
48 50 Hz, n = 1450 min-1
ISO 9906 Grade 2
ø385
44
40
ø347
36
32
ø308
28
24
20
16
NPSH
[m]
12 12
ø385 (NPSH)
ø308 (NPSH)
8 8
4 4
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [m³/h]
P2 Eta
[kW] [%]
360 90
320 80
280 70
ø385
240 ø347 60
ø308
ø385
200 50
160 ø347 40
120 ø308 30
80 20
40 10
TM03 2835 5005
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [m³/h]
118
Technical data HS 350-350-390
4-pole
Dimensional sketch
HS extended, 350-350-390
119
Performance curves HS 450-350-440
4-pole
H
[m]
HS 450-350-440
65
50 Hz, n = 1450 min-1
ISO 9906 Grade 2
ø433
60
55
50
ø390
45
40
ø346
35
30
25
NPSH
[m]
20 25
ø433 (NPSH)
15 20
ø346 (NPSH)
10 15
5 10
0 5
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [m³/h]
P2 Eta
[kW] [%]
800 80
700 70
600 ø433 60
ø390
ø346
500 50
400 ø433 40
300 ø390 30
ø346
200 20
100 10
TM03 2836 5005
0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [m³/h]
120
Technical data HS 450-350-440
4-pole
Dimensional sketch
HS extended, 450-350-440
121
Performance curves HS 450-350-540
4-pole
H
[m]
HS 450-350-540
100 50 Hz, n = 1450 min-1
ø535 ISO 9906 Grade 2
90
80
ø482
70
60 ø428
50
NPSH
[m]
40 20
ø535 (NPSH)
30 16
ø482 (NPSH)
20 ø428 (NPSH) 12
10 8
0 4
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [m³/h]
P2 Eta
[kW] [%]
1000 90
900 80
ø535
800 ø482 70
ø428
ø535
700 60
600 50
ø482
500 40
400 30
ø428
300 20
200 10
TM03 2837 5005
100 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [m³/h]
122
Technical data HS 450-350-540
4-pole
Dimensional sketch
HS extended, 450-350-540
123
Performance curves HS 450-350-660
4-pole
H
[m]
HS 450-350-660
170
50 Hz, n = 1450 min-1
ø660 ISO 9906 Grade 2
160
150
140
ø594
130
120
110
ø528
100
90
80
70 NPSH
[m]
60 16
ø528 (NPSH)
50 ø660 (NPSH) 12
40 8
30 4
20 0
0 400 800 1200 1600 2000 2400 2800 3200 Q [m³/h]
P2 Eta
[kW] [%]
1800 90
1600 80
ø660
1400 ø594 70
ø528 ø660
1200 60
1000 50
ø594
800 40
ø528
600 30
400 20
200 10
TM03 2838 5005
0 0
0 400 800 1200 1600 2000 2400 2800 3200 Q [m³/h]
124
Technical data HS 450-350-660
4-pole
Dimensional sketch
HS extended, 450-350-660
125
Performance curves HS 200-150-480-2
6-pole
6-pole
H
[m]
76
HS 200-150-480-2
50 Hz, n = 970 min-1
ø475 ISO 9906 Grade 2
72
68
64
60
ø428
56
52
48
ø380
44
40
36
32
28 NPSH
[m]
24 6
ø475 (NPSH)
20 ø380 (NPSH) 4
16 2
12 0
0 40 80 120 160 200 240 280 320 360 400 Q [m³/h]
P2 Eta
[kW] [%]
90 80
80 70
ø475
ø380 ø428 ø475
70 60
60 50
ø428
50 40
40 30
ø380
30 20
20 10
TM03 2861 5005
10 0
0 40 80 120 160 200 240 280 320 360 400 Q [m³/h]
126
Technical data HS 200-150-480-2
6-pole
Dimensional sketch
HS two-stage through-bore, 200-150-480-2
127
Performance curves HS 250-200-580
6-pole
H
[m]
HS 250-200-580
56 50 Hz, n = 970 min-1
ISO 9906 Grade 2
ø580
52
48
44
ø522
40
36
ø464
32
28
NPSH
[m]
24 5
ø580 (NPSH)
ø464 (NPSH)
20 4
16 3
12 2
8 1
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 Q [m³/h]
P2 Eta
[kW] [%]
160 80
ø580
140 ø464 ø522 70
120 60
100 ø580 50
80 40
ø522
60 30
ø464
40 20
20 10
TM03 3956 1306
0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 Q [m³/h]
128
Technical data HS 250-200-580
6-pole
Dimensional sketch
HS extended, 250-200-580
129
Performance curves HS 250-200-580-2
6-pole
H
[m]
110 HS 250-200-580-2
ø575
50 Hz, n = 970 min-1
105
ISO 9906 Grade 2
100
95
90
85 ø518
80
75
70
ø460
65
60
55
50
45
40
35
30
NPSH
ø518 (NPSH) [m]
25 4
ø460 (NPSH) ø575 (NPSH)
20 3
15 2
10 1
0 50 100 150 200 250 300 350 400 450 500 550 600 650 Q [m³/h]
P2 Eta
[kW] [%]
200 80
180 ø575 70
ø460 ø518 ø575
160 60
140 50
120 ø518 40
100 30
80 ø460 20
60 10
TM03 2862 5005
40 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 Q [m³/h]
130
Technical data HS 250-200-580-2
6-pole
Dimensional sketch
HS two-stage through-bore, 250-200-580-2
131
Performance curves HS 300-250-420
6-pole
H
[m]
HS 300-250-420
28
50 Hz, n = 970 min-1
ISO 9906 Grade 2
26 ø415
24
22
ø375
20
18
ø332
16
14
12
10
8 NPSH
[m]
6 6
ø415 (NPSH)
4 ø332 (NPSH) 4
2 2
0 0
0 100 200 300 400 500 600 700 800 900 1000 Q [m³/h]
P2 Eta
[kW] [%]
90 90
80 80
ø415
ø375
70 70
ø332 ø415
60 60
50 50
40 ø375 40
30 ø332 30
20 20
10 10
TM03 2850 5005
0 0
0 100 200 300 400 500 600 700 800 900 1000 Q [m³/h]
132
Technical data HS 300-250-420
6-pole
Dimensional sketch
HS extended, 300-250-420
133
Performance curves HS 300-250-510
6-pole
H
[m]
42
ø510 HS 300-250-510
50 Hz, n = 970 min-1
40 ISO 9906 Grade 2
38
36
ø480
34
32
30
28
ø410
26
24
22
20
18 NPSH
[m]
16 6
ø510 (NPSH)
14 4
ø410 (NPSH)
12 2
10 0
0 100 200 300 400 500 600 700 800 900 1000 Q [m³/h]
P2 Eta
[kW] [%]
180 90
160 80
ø510
140 ø480 70
120 ø410 60
100 ø510 50
80 40
ø480
60 30
ø410
40 20
20 10
TM03 2851 5005
0 0
0 100 200 300 400 500 600 700 800 900 1000 Q [m³/h]
134
Technical data HS 300-250-510
6-pole
Dimensional sketch
HS extended, 300-250-510
135
Performance curves HS 300-250-680
6-pole
H
[m]
HS 300-250-680
76
50 Hz, n = 970 min-1
ø677
ISO 9906 Grade 2
72
68
64
60 ø609
56
52
48 ø542
44
40
36 NPSH
[m]
32 ø677 (NPSH) 12
28 ø542 (NPSH) 8
24 4
20 0
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [m³/h]
P2 Eta
[kW] [%]
320 80
280 70
ø609 ø677
ø542
240 60
ø677
200 50
ø609
160 40
120 ø542 30
80 20
40 10
TM03 2852 5005
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [m³/h]
136
Technical data HS 300-250-680
6-pole
Dimensional sketch
HS extended, 300-250-680
137
Performance curves HS 350-300-340
6-pole
H
[m]
16
HS 350-300-340
ø337
50 Hz, n = 970 min-1
15 ISO 9906 Grade 2
14
ø313
13
12
11 ø290
10
5 NPSH
[m]
4 8
3 6
ø337 (NPSH)
ø313 (NPSH)
2 4
ø290 (NPSH)
1 2
0 0
0 100 200 300 400 500 600 700 800 900 1000 Q [m³/h]
P2 Eta
[kW] [%]
40 80
35 70
ø337
30 ø313 60
ø290
25 ø337 50
20 40
ø313
15 30
ø290
10 20
5 10
TM03 2853 5005
0 0
0 100 200 300 400 500 600 700 800 900 1000 Q [m³/h]
138
Technical data HS 350-300-340
6-pole
Dimensional sketch
HS extended, 350-300-340
139
Performance curves HS 350-300-480
6-pole
H
[m]
ø475 HS 350-300-480
34
50 Hz, n = 970 min-1
ISO 9906 Grade 2
32
30
28
ø427
26
24
22
ø380
20
18
16
14
12 NPSH
[m]
10 6
ø427 (NPSH)
ø380 (NPSH)
8 ø475 (NPSH) 4
6 2
4 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [m³/h]
P2 Eta
[kW] [%]
180 90
160 80
ø380 ø427 ø475
140 70
120 ø475 60
100 50
ø427
80 40
60 ø380 30
40 20
20 10
TM03 2854 5005
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [m³/h]
140
Technical data HS 350-300-480
6-pole
Dimensional sketch
HS extended, 350-300-480
141
Performance curves HS 350-300-590
6-pole
H
[m]
56
ø585 HS 350-300-590
50 Hz, n = 970 min-1
54 ISO 9906 Grade 2
52
50
48
46 ø526
44
42
40
38
36 ø468
34
32
30 NPSH
[m]
28 ø585 (NPSH) 6
26 ø468 (NPSH) 4
ø526 (NPSH)
24 2
22 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [m³/h]
P2 Eta
[kW] [%]
360 90
320 80
ø468 ø526 ø585
280 70
240 60
ø585
200 50
160 ø526 40
120 30
ø468
80 20
40 10
TM03 2855 5005
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [m³/h]
142
Technical data HS 350-300-590
6-pole
Dimensional sketch
HS extended, 350-300-590
143
Performance curves HS 350-300-770
6-pole
H
[m]
96
HS 350-300-770
ø774
50 Hz, n = 970 min-1
92 ISO 9906 Grade 2
88
84
80
ø697
76
72
68
64
ø619
60
56
52
48
44 NPSH
[m]
40 6
ø619 (NPSH) ø774 (NPSH)
36 4
32 2
28 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600Q [m³/h]
P2 Eta
[kW] [%]
900 90
800 80
700 ø774 70
ø619 ø697
600 60
500 50
ø774
400 40
ø697
300 30
ø619
200 20
100 10
TM03 2856 5005
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [m³/h]
144
Technical data HS 350-300-770
6-pole
Dimensional sketch
HS extended, 350-300-770
145
Performance curves HS 350-350-390
6-pole
H
[m]
20 ø385
HS 350-350-390
50 Hz, n = 970 min-1
19 ISO 9906 Grade 2
18
17
16 ø347
15
14
13
ø308
12
11
10
7 NPSH
[m]
6 6
ø385 (NPSH)
ø308 (NPSH)
5 4
4 2
3 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [m³/h]
P2 Eta
[kW] [%]
100 90
90 80
80 70
ø385
70 ø347 60
ø308 ø385
60 50
50 ø347 40
40 30
ø308
30 20
20 10
TM03 2857 5005
10 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [m³/h]
146
Technical data HS 350-350-390
6-pole
Dimensional sketch
HS extended, 350-350-390
147
Performance curves HS 450-350-440
6-pole
H
[m]
HS 450-350-440
28
ø433 50 Hz, n = 970 min-1
ISO 9906 Grade 2
26
24
22 ø390
20
18
ø346
16
14
12
10
8 NPSH
[m]
6 12
ø346 (NPSH) ø433 (NPSH)
4 8
2 4
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [m³/h]
P2 Eta
[kW] [%]
180 80
160 70
140 ø433 60
ø346 ø390
120 ø433 50
100 40
ø390
80 30
ø346
60 20
40 10
TM03 2858 5005
20 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [m³/h]
148
Technical data HS 450-350-440
6-pole
Dimensional sketch
HS extended, 450-350-440
149
Performance curves HS 450-350-540
6-pole
H
[m]
44
HS 450-350-540
ø535
50 Hz, n = 970 min-1
42 ISO 9906 Grade 2
40
38
36
ø482
34
32
30
28
ø428
26
24
22
20
18
16 NPSH
[m]
14 ø535 (NPSH) 8
ø482 (NPSH)
ø435 (NPSH)
12 4
10 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [m³/h]
P2 Eta
[kW] [%]
360 90
320 80
ø535
280 ø482 70
ø428
240 60
ø535
200 50
160 ø482 40
120 ø428 30
80 20
40 10
TM03 2859 5005
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [m³/h]
150
Technical data HS 450-350-540
6-pole
Dimensional sketch
HS extended, 450-350-540
151
Performance curves HS 450-350-660
6-pole
H
[m]
76
HS 450-350-660
50 Hz, n = 970 min-1
ø660 ISO 9906 Grade 2
72
68
64
60
ø594
56
52
48
ø528
44
40
36
32 NPSH
ø660 (NPSH)
[m]
28 8
ø528 (NPSH)
24 6
20 4
16 2
12 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [m³/h]
P2 Eta
[kW] [%]
500 90
450 80
ø660
400 ø594 70
ø528 ø660
350 60
300 50
ø594
250 40
ø528
200 30
150 20
100 10
TM03 2860 5005
50 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [m³/h]
152
Technical data HS 450-350-660
6-pole
Dimensional sketch
HS extended, 450-350-660
153
Bare shaft pumps HS standard
Pump
Pump Suction Discharge
j1 j2 v n1 n2 n3 a f h1 h3 c s z m1 m2 m3 d-Tol e e1 u t Net wt.
size ø ø
[Kg]
80-50-380 80 50 355 280 170 400 340 65 246 314 300 321 25 22 - 330 270 65 25-j6 70 63 28 8 175
80-65-240 80 65 280 225 130 350 290 65 246 314 250 254 25 22 - 300 240 65 25-j6 70 63 28 8 118
80-65-380 80 65 325 275 175 400 300 100 238 292 300 275 25 23 - 240 190 70 25-m6 55 50 28 8 164
100-80-240 100 80 270 230 130 350 290 65 246 314 280 249 25 22 - 300 240 65 25-j6 70 63 28 8 126
100-80-300 100 80 290 275 150 350 290 65 246 314 280 274 25 22 - 300 240 65 25-j6 70 63 28 8 135
100-80-380 100 80 340 350 175 400 340 65 246 314 320 325 25 22 - 330 270 65 25-j6 70 63 28 8 194
125-100-300 125 100 320 275 170 350 290 65 246 314 320 299 25 22 - 300 240 65 25-j6 70 63 28 8 175
125-100-380 125 100 340 350 190 450 390 75 301 401 340 346 25 22 - 330 270 75 42-k6 100 90 45 12 227
150-100-240 150 100 310 250 170 350 290 75 301 401 340 308 25 22 - 300 240 75 42-k6 100 90 45 12 203
150-125-240 150 125 350 250 180 400 340 75 277 345 340 295 25 22 - 330 270 75 25-j6 70 63 28 8 226
150-125-290 150 125 310 290 160 350 290 75 246 314 340 293 25 22 - 300 240 75 25-j6 70 63 28 8 185
150-125-300 150 125 335 290 175 400 340 75 277 345 340 309 25 22 - 330 270 75 25-j6 70 63 28 8 238
150-125-380 150 125 400 350 210 450 390 75 301 401 390 380 25 22 - 330 270 75 42-k6 100 90 45 12 310
200-150-240 200 150 365 310 200 400 340 75 277 345 390 303 25 22 - 330 270 75 25-j6 70 63 28 8 255
200-150-300 200 150 365 315 235 400 340 75 301 401 440 359 25 22 - 420 360 75 42-k6 100 90 45 12 315
200-150-380 200 150 410 350 210 400 340 75 301 401 440 376 25 22 - 420 360 75 42-k6 100 90 45 12 355
200-150-450 200 150 430 355 269 450 350 100 315 378 450 350 25 23 - 370 310 75 42-m6 90 87 45 12 420
200-150-480 200 150 510 450 270 560 490 90 371 496 540 452 28 28 - 460 390 90 55-m6 127 100 56 16 570
250-200-300 250 200 450 385 285 510 450 75 346 446 540 381 25 22 - 500 440 75 42-k6 100 90 45 12 515
250-200-380 250 200 480 420 225 510 440 90 371 496 460 409 28 28 - 420 350 90 55-m6 127 100 56 16 500
250-200-480 250 200 550 450 270 560 490 90 371 496 540 445 28 28 - 500 430 90 55-m6 127 100 56 16 647
250-250-240 250 250 490 340 210 400 340 75 346 446 440 375 25 22 - 420 360 75 42-k6 100 90 45 12 390
250-250-300 250 250 430 400 250 510 450 75 346 446 540 389 25 22 - 500 440 75 42-k6 100 90 45 12 460
250-250-380 250 250 540 420 265 570 470 100 322 410 475 310 25 23 - 490 410 85 42-m6 90 87 45 12 420
300-250-380 300 250 590 420 265 560 490 90 371 496 540 471 28 28 - 500 430 90 55-m6 127 100 56 16 660
154
Technical data HS standard
Pump
Pump Suction Discharge
j1 j2 v n4 n5 n6 a f h1 h2 c s z w m2 m3 d-Tol e e1 u t Net wt.
size ø ø
[Kg]
80-50-380 80 50 355 280 170 400 340 65 331 399 300 321 25 22 - 330 270 65 25-j6 70 63 8 28 186
80-65-240 80 65 280 225 130 350 290 65 331 399 250 254 25 22 - 300 240 65 25-j6 70 63 8 28 129
80-65-380 80 65 325 275 175 400 300 100 321 375 300 275 25 23 - 240 190 70 25-m6 55 50 8 28 164
100-80-240 100 80 270 230 130 350 290 65 331 399 280 249 25 22 - 300 240 65 25-j6 70 63 8 28 137
100-80-300 100 80 290 275 150 350 290 65 331 399 280 274 25 22 - 300 240 65 25-j6 70 63 8 28 150
100-80-380 100 80 340 350 175 400 340 65 331 399 320 325 25 22 - 330 270 65 25-j6 70 63 8 28 205
125-100-300 125 100 320 275 170 350 290 65 331 399 320 299 25 22 - 300 240 65 25-j6 70 63 8 28 186
125-100-380 125 100 340 350 190 450 390 75 400 500 340 346 25 22 - 330 270 75 42-k6 100 90 12 45 248
150-100-240 150 100 310 250 170 350 290 75 400 500 340 308 25 22 - 300 240 75 42-k6 100 90 12 45 224
150-125-240 150 125 350 250 180 400 340 75 362 430 340 295 25 22 - 330 270 75 25-j6 70 63 8 28 238
150-125-290 150 125 310 290 160 350 290 75 331 399 340 293 25 22 - 300 240 75 25-j6 70 63 8 28 196
150-125-300 150 125 335 290 175 400 340 75 362 430 340 309 25 22 - 330 270 75 25-j6 70 63 8 28 249
150-125-380 150 125 400 350 210 450 390 75 400 500 390 380 25 22 - 330 270 75 42-k6 100 90 12 45 331
200-150-240 200 150 365 310 200 400 340 75 362 430 390 303 25 22 - 330 270 75 25-j6 70 63 8 28 265
200-150-300 200 150 365 315 235 400 340 75 400 500 440 359 25 22 - 420 360 75 42-k6 100 90 12 45 336
200-150-380 200 150 410 350 210 400 340 75 400 500 440 376 25 22 - 420 360 75 42-k6 100 90 12 45 376
200-150-440 200 150 430 355 269 450 350 100 392 480 450 350 25 23 - 370 310 75 42-m6 90 87 12 45 308
200-150-480 200 150 510 450 270 560 490 90 460 585 540 452 28 28 - 460 390 90 55-m6 127 100 16 56 595
250-200-300 250 200 450 385 285 510 450 75 445 545 540 381 25 22 - 500 440 75 42-k6 100 90 12 45 535
250-200-380 250 200 480 420 225 510 440 90 460 585 460 409 28 28 - 420 350 90 55-m6 127 100 16 56 530
250-200-480 250 200 550 450 270 560 490 90 460 585 540 445 28 28 - 500 430 90 55-m6 127 100 16 56 675
250-250-240 250 250 490 340 210 400 340 75 445 545 440 375 25 22 - 420 360 75 42-k6 100 90 12 45 415
250-250-300 250 250 430 400 250 510 450 75 445 545 540 389 25 22 - 500 440 75 42-k6 100 90 12 45 489
250-250-380 250 250 540 420 265 570 470 100 424 512 475 310 25 23 - 490 410 85 42-m6 90 87 12 45 420
300-250-380 300 250 590 420 265 560 490 90 460 585 540 471 28 28 - 500 430 90 55-m6 127 100 16 56 685
155
Technical data HS extended
Pump
Pump Suction Discharge
j1 j2 v n4 n5 n6 a f h1 h2 c s z w m2 m3 d e e1 u t Net wt.
size ø ø
[Kg]
350-300-340 350 300 600 450 330 240 380 60 495 615 650 355 25 18.5 - 415 400 50 65 105 80 20 69.9 745
300-250-420 300 250 650 550 310 350 350 70 600 740 580 355 28 23 - 510 460 55 85 125 95 22 90.4 905
300-250-510 300 250 650 600 310 350 350 70 600 740 580 380 28 23 - 510 460 55 85 125 95 22 90.4 971
300-250-680 300 250 700 700 400 430 430 70 600 740 700 480 30 23 - 510 460 55 85 125 95 22 90.4 1455
350-300-590 350 300 650 700 370 350 350 70 600 740 700 440 28 23 - 510 460 55 85 125 95 22 90.4 1354
350-350-390 350 350 700 500 370 330 330 70 600 740 700 400 28 23 - 510 460 55 85 125 95 22 90.4 1020
350-300-480 350 300 680 600 345 400 400 70 683 852 650 410 28 23 - 547 610 55 95 150 130 25 100.4 1050
350-300-770 350 300 800 800 450 500 500 100 683 852 800 545 28 27 - 527 650 55 95 150 130 25 100.4 2000
450-350-440 450 350 700 600 400 400 400 70 683 852 750 455 28 27 - 527 650 55 95 150 130 25 100.4 1429
450-350-540 450 350 700 600 400 400 400 70 683 852 750 456 28 27 - 527 650 55 95 150 130 25 100.4 1660
450-350-660 450 350 740 750 420 400 400 80 683 852 800 500 28 27 - 527 650 55 95 150 130 25 100.4 1956
156
Technical data HS two-stage through-bore
Pump
Pump Suction Discharge
j1 j2 v n6 x y a f h h1 c m2 m3 p1 p2 d e e1 u t Net wt.
size ø ø
[Kg]
200-150-480-2 200 150 575 550 260 70 300 300 495 615 870 500 20 460 50 65 65 50 105 73 14 53.9 980
250-200-580-2 250 200 750 600 310 80 500 350 655 800 1045 600 30 620 50 75 75 85 125 95 22 90.4 1600
157
Technical data HS two-stage non-through-bore
Pump
Pump Suction Discharge
j1 j2 p n1 n2 n5 a f h1 h2 q q1 q2 q3 r r1 r2 d e u Net wt.
size ø ø
[Kg]
125-100-360-2 125 100 350 340 140 520 400 - 441 540 350 340 401 110 260 210 120 75 34 32 99 10 325
150-125-420-2 150 125 375 365 150 520 400 - 479 575 400 365 385 100 360 300 120 100 40 42 80 12 478
200-150-440-2 200 150 425 400 175 625 505 265 506 623 425 435 428 150 360 300 120 120 45 50 100 14 612
158
Accessories HS
• The suction diffuser provides and ensures a uniform 2 Cover 6 Drain plug
flow pattern to the suction side of the pump. This en- 3 Strainer (inside) 7 O-ring
159
Accessories HS
Pressure drop
In operation the suction diffuser causes a minor pres-
sure drop.
10000 350A
300A
250A
200A
150A
125A
100A
1000
80A
Flow rate [m3/h]
100
10
DN size of
Product number
inlet/outlet
1 SD 12 SD 22
80 x 80 95043154 95043354
TM03 2590 1106
160
Accessories HS
Mode of operation
Tighten the activating screw in the bottom of the car-
tridge and a gas generating pellet will drop into a liquid
electrolyte starting a chemical reaction. The pressure
TM03 3747 0906
Product numbers
Pt 100 can be ordered using this product number:
95043173.
161
162
163
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence
96624465 0606
96624465 0306
Repl.:
GB
Subject to alterations.
www.grundfos.com