You are on page 1of 130

North America

Inverter Single Wall Mounted


(60Hz/R410A)
6RMI0-06A

6RMI0-06A

Inverter Single-60Hz
(R410A)
1. Models Line up ........................................................................................................6
2. Nomenclature ..........................................................................................................9
3. Specifications........................................................................................................10
4. Dimensional drawings ..........................................................................................22
5. Wiring diagrams ....................................................................................................34
6. Refrigerant cycle diagram ....................................................................................44
7. Capacity tables......................................................................................................54
8. Capacity coefficient factor ...................................................................................78
9. Electric characteristics.........................................................................................83
10. Operation range ..................................................................................................84
11. Air flow and temperature distributions(Reference data) .................................87
12. Sound levels (Reference data)...........................................................................92
13. Remote controller ...............................................................................................96
14. Installation .........................................................................................................102

Inverter Single

6RMI0-06A

Publication history

Plb.No

Applied model

Notes

Publication in

6RMI0-04A

LSN090HYV / LSN120HYV
LAN090HSV2 / LAN120HSV2
LAN180HSV2 / LAN240HSV2
LSN091HSV2 / LSN121HSV2
LSN181HSV2 / LSN240HSV2
LSN307HV2 / LSN360HV2
LAN090HVP / LAN120HVP

Add 12 New Models

April. 2012

6RMI0-05A

LSN090HEV
LSN120HEV
LSN180HEV
LSN240HEV

Add 13 New Models

Jan, 2013

6RMI0-06A

LAN090HYV / LAU090HYV
LAN120HYV/LAU120HYV
LSN091HSV3/LSU091HSV3
LSN121HSV3/LSU121HSV3
LSN181HSV3/LSU181HSV3
LSN240HSV3/LSU240HSV3
LSN307HV3/LSU307HV3
LSN360HV3/LSU360HV3

Add 13 New Models

May, 2013

Inverter Single

6RMI0-06A

Test condition of international standard


KSC
9306

ISO
5151

ARI
210/240

AHAM

AS
1861.1

SSA
385

DBC(F)

27.0

27.0

26.7(80)

26.7(80)

27.0

29.0

WBC(F)

19.5

19.0

19.4(67)

19.4(67)

19.0

19.0

DBC(F)

35.0

35.0

35.0(95)

35.0(95)

35.0

46.0

WBC(F)

24.0

24.0

23.9(75)

23.9(75)

24.0

24.0

DBC(F)

20.0

20.0

21.1(70)

21.1(70)

21.0

21.0

WBC(F)

15.0

15.0

15.6(60)

15.6(60)

15.0

15.5

DBC(F)

7.0

7.0

8.3(47)

8.3(47)

7.0

7.0

WBC(F)

6.0

6.0

6.1(43)

6.1(43)

6.0

6.0

DBC(F)

32.0

32.0

26.7(80)

32.2(90)

32.0

29.0

WBC(F)

23.0

23.0

19.4(67)

22.8(73)

23.0

19.0

DBC(F)

43.0

43.0

46.1(115)

43.3(110)

43.0

54.0

WBC(F)

26.0

26.0

23.9(75)

25.6(78)

26.0

24.0

DBC(F)

27.0

27.0

26.7(80)

26.7(80)

WBC(F)

19.0

19.0

19.4(67)

22.8(73)

DBC(F)

21.0

24.0

23.9(75)

23.9(75)

WBC(F)

15.0

18.0

18.3(65)

18.3(65)

DBC(F)

27.0

27.0

26.7(80)

26.7(80)

27.0

27.0

WBC(F)

24.0

24.0

23.9(75)

23.9(75)

24.0

24.0

DBC(F)

27.0

27.0

26.7(80)

26.7(80)

27.0

27.0

WBC(F)

24.0

24.0

23.9(75)

23.9(75)

24.0

24.0

DBC(F)

21.0

21.0

19.4(67)

21.1(70)

21.0

21.0

WBC(F)

15.0

15.0

13.9(57)

15.6(60)

16.0

16.0

DBC(F)

21.0

21.0

19.4(67)

21.1(70)

21.0

21.0

WBC(F)

15.0

15.0

13.9(57)

15.6(60)

16.0

16.0

CLASSIFICATION
Indoor
Cooling
Capacity

Outdoor

Indoor
Heating
Capacity

Maximum

Outdoor

Indoor

Cooling
Operating

Outdoor

Maximum

Indoor

Heating
Operating
Enclosure

Outdoor

Indoor

Sweat /
Condensate

Outdoor

Disposal
Freeze-up/

Indoor

Low
Temperature Outdoor

KS : Korea Standard
AS : Australia Standard
ISO : International Standard Organization
SSA : Saudi Arabian Standard
ARI : Airconditioning and Refrigeration Institute
AHAM : Association of Home Appliance Manufacturers

Inverter Single

6RMI0-06A

General Description
Split system type air conditioners are known by the category name of Wall Mounted Type systems. The indoor
and outdoor unit can be easily installed in a small space and have exceptional cooling capacity. Designed for lownoise operation, these systems ensure a pleasant air conditioned environment.
LG offers various types of units to its customers to satisfy various applications and requirements. The following
are the important categories offered by LG :
1) Art Cool Units : A new concept of cooling introduced by LG in the field of Air Conditioning.
2) Inverter Units : These units are capable of minimising the power consumption with unique inverter technology.

Some of the important features of these units are listed below :


1) Long Term Money Saving : By providing the features such as Gold Fin, Auto Clean etc. to maintain the same
performance for years.
2) Best Comfort : With features such as Sleep Mode,Timer,Auto Restart etc.
The units are available with many standard and optional features which give our customers the choice to select
the unit of their own desire.For more information refer to the detailed specification following this description.

LG Electronics Inc.
Air Conditioning & Energy Solution Company

Inverter Single

6RMI0-06A

1. Models Line up
1.1 Indoor Unit
Type
2.64(9)

Art Cool Premier

3.28(12)

Model names
kW(kBtu/h)
5.33(18)
6.45(24)

8.79(30)

9.67(36)

ASNW093MMM9 ASNW123MMM9
(LSN090HYV)
(LSN120HYV)
ASNW093MMB8 ASNW123MMB8
(LAN090HYV)
(LAN120HYV)

Art Cool Gallery


ASNW093F2B2
(LAN090HVP)

ASNW123F2B2
(LAN120HVP)

Art Cool Mirror


ASNW093BRM9 ASNW123BRM9 ASNW183CRM9 ASNW243CRM9
(LAN090HSV2) (LAN120HSV2) (LAN180HSV2) (LAN240HSV2)

Wall Mounted

ASNW093B1Y9
(LSN091HSV2)
ASNW093B1B8
(LSN091HSV3)

ASNW123B1Y9
(LSN121HSV2)
ASNW123B1B8
(LSN121HSV3)

ASNW183C2Y9
(LSN181HSV2)
ASNW183C2B8
(LSN181HSV3)
ASNW243DGY9 ASNW303DGY9 ASNW363DGY9
(LSN240HSV2)
(LSN307HV2)
(LSN360HV2)

Wall Mounted

ASNW243D8B8
(LSN240HSV3)

ASNW303D8B8
(LSN307HV3)

ASNW363D8B8
(LSN360HV3)

Mega
ASNW093WSA7 ASNW123BSA7 ASNW183CSA7 ASNW243CSA7
(LSN090HEV)
(LSN120HEV)
(LSN180HEV)
(LSN240HEV)

Inverter Single

Models Line up

6RMI0-06A

1.2 Outdoor Unit


ASUW093B1Y9(LSU091HSV2)
ASUW093BRM9(LAU090HSV2)
ASUW093FUB2(LAU090HVP)
ASUW093MMB8 (LAU090HYV)
ASUW093B1B8(LSU091HSV3)

Heat pump

Total capacity index of


connectable indoor units

ASUW123B1Y9(LSU121HSV2)
ASUW123BRM9(LAU120HSV2)
ASUW123FUB2(LAU120HVP)
ASUW183CSA7(LSU180HEV)
ASUW123MMB8(LAU120HYV)
ASUW123B1B8(LSU121HSV3)

kW

2.64

3.28

5.33

kBtu/h

12

18

Power supply

1, 208~230V, 60Hz

Chassis

UL2

Heat pump

Total capacity index of


connectable indoor units

ASUW093MMM9(LSU090HYV) ASUW123MMM9(LSU120HYV)

kW
kBtu/h

2.64
9

3.51
12
1, 208~230V, 60Hz

Power supply

Chassis

UE

Inverter Single

ASUW243CSA7(LSU240HEV)

6.45
24

6RMI0-06A

Models Line up

Heat pump

Total capacity index of


connectable indoor units

kW
kBtu/h

ASUW183C2Y9(LSU181HSV2)
ASUW183CRM9(LAU180HSV2)
ASUW183C2B8(LSU181HSV3)

ASUW243DGY9(LSU240HSV2)
ASUW243CRM9(LAU240HSV2)
ASUW243D8B8(LSU240HSV3)

5.33
18

6.45
24

Power supply

1, 208~230V, 60Hz

Chassis

UE1+

Heat pump

Total capacity index of


connectable indoor units

kW
kBtu/h

ASUW303DGY9(LSU307HV2)
ASUW303D8B8(LSU307HV3)

ASUW363DGY9(LSU360HV2)
ASUW363D8B8(LSU360HV3)

8.79
30

9.67
36

Power supply

1, 208~230V, 60Hz

UE1+

Chassis

Heat pump

Total capacity index of


connectable indoor units

kW
kBtu/h

ASUW093WSA7(LSU090HEV)

ASUW123BSA7(LSU120HEV)

2.64
9

3.28
12

Power supply

Chassis

1, 208~230V, 60Hz

UA3+

Inverter Single

Models line up

6RMI0-06A

2. Nomenclature
Model Number
A

Serial Number
Function
A: Non Plasma + 2Way
H : Plasma + (A/chageove) + A/Clean + 4Way + Low A
U : Plasma + Allergy Filter + 4Way
Z : Basic + (A/clean) + 4Way + Low A
Look/Color
Chassis

Look
Classification
1
White + Silver deco
SB
R
Mirror
S
Wite Panel : 1 piece
2
White + Silver deco
SC
R
Mirror
S
Wite Panel : 1 piece
SW
S
Wite Panel : 1 piece
SE
R
Mirror
S8
R
Mirror
SD
G
Grill Type
Chassis name
SM
M
White
Ex) B : SB, C : SC, W
: SW
SF
2
Gallary
E : SE, 8 : S8, D
: SD, M : SM
Electric Ratings
3 : 1, 208-230V, 60Hz
Capacity
Ex) 09 9,000 Btu/h Class
Model Type
C : Cooling Only
H : Heat Pump
Q : DC Inverter C/O
W : DC Inverter H/P
Supply method dividing and Type
- : SET
N : Indoor Unit
U : Outdoor Unit
Product type
S: Split
Refrigerant type & code
L: R22
A: R410A

Inverter Single

6RMI0-06A

Nomenclature

3. Specifications
Wall Mount Inverter
Sales Model
Models
Cooling Capacity
Heating Capacity
Power Input
Running Current
Starting Current
Cooling COP
EER
SEER
HSPF
Power Supply
Power Factor
Air Flow Rate

Cooling/Heating
Cooling/Heating
Cooling/Heating

Indoor, Max/H/M/L
Outdoor,Max

Moisture Removal
Sound Level

Indoor,H/M/L
Outdoor,Max
Refrigerant & Charge (at 7.5 m/24.6 ft)
Additional Refrigerant charge
Compressor
Type
Model
Motor Type
Oil Type
Oil Charge
O.L.P. name
Fan(Indoor)
Type
Motor Output
Fan(Outdoor)
Type
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Power and Transmission Cable
Piping Connections
Liquid Side
Gas Side
Drain Hose(O.D / I.D.)
Dimensions
Indoor (W*H*D)
Outdoor (W*H*D)
Net Weight
Gross Weight
Operation Range
Piping Length (Min/Max)
Chargeless
Max. Elevation Difference
Tool Code(Chassis)
Functions

Indoor
Outdoor
Indoor
Outdoor
Cooling(Outdoor)
Heating(Outdoor)

Unit
kW
Btu/h.
kW
Btu/h.
W
A
A

/ V / Hz
%
m3/min(CFM)
m3/min(CFM)
l/h.(pts/hr)
dB(A)3
dB(A)3
g(oz)
g/m(oz/ft)

cc

W
A
No.*mm2(AWG)
No.*mm2(AWG)
mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
kg(lbs)
kg(lbs)
C()DB
C()WB
m(ft)
m(ft)
m(ft)

Indoor + Outdoor
Temperature Control
Allergy free filter
Plasma Filter
Prefilter(washable/anti-fungus)
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up& Down)
Airflow Direction Control(left & right)
Remote Controller Type
Setting Temperature
Cooling
Range
Heating
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Optional Function

LSN091HSV2/LSU091HSV2
AS-W093B1Y9
2.64
9,000
3.17
10,800
677 / 700
3.0 /3.7
3.0 /3.7
3.90
13.3
20
11.0
1/208-230/60
93
11.0(388)/9.5(335)/7.7(272)/6.0(212)
33(1,165)
1.1(2.6)
38 / 33 / 24
45
R410A, 1,000(35.3)
20(0.22)
Rotary
5RS102XAA21
Brushless DC Motor
PVE(FV50S)
320
Cross Flow Fan
20
Propeller
BLDC
43
15
3*1.0(18)
4*1.0(18)
6.35(1/4)
9.52(3/8)
21.5 / 16.0(27/32 / 5/8)
885*285*210
34 13/16* 11 1/4* 8 1/4
770*545*288
30 5/16*21 1/2*11 5/16
10(22.1)
35(77.2)
12(26.5)
37(81.6)
-10(-18)*~48(14(0)*~118)
-15~24(5~75)
2(6.6) / 20(65.6)
12.5(41.0)
10(32.8)
SB + UL2
Thermistor
O
O
O
O
6/6/6
Auto
Auto
Wireless Remote Controller
18(64.4)~ 30(86)
16(60.8)~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
O
WATER LEVEL SENSOR, WIND FAFFLE KIT

LSN121HSV2/LSU121HSV2
AS-W123B1Y9
3.28
11,200
3.90
13,300
896 / 1,000
4.2 / 4.9
4.2 / 4.9
3.66
12.5
20
11.0
1/208-230/60
97.1
12.0(423)/10.0(353)/7.7(272)/6.0(212)
33(1,165)
1.3(3.0)
39 / 33 / 24
45
R410A, 1,000(35.3)
20(0.22)
Rotary
5RS102XAA21
Brushless DC Motor
PVE(FV50S)
320
Cross Flow Fan
20
Propeller
BLDC
43
15
3*1.0(18)
4*1.0(18)
6.35(1/4)
9.52(3/8)
21.5 / 16.0(27/32 / 5/8)
885*285*210
34 13/16* 11 1/4* 8 1/4
770*545*288
30 5/16*21 1/2*11 5/16
10(22.1)
35(77.2)
12(26.5)
37(81.6)
-10(-18)*~48(14(0)*~118)
-15~24(5~75)
2(6.6) / 20(65.6)
12.5(41.0)
10(32.8)
SB + UL2
Thermistor
O
O
O
O
6/6/6
Auto
Auto
Wireless Remote Controller
18(64.4)~ 30(86)
16(60.8)~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
O
WATER LEVEL SENSOR, WIND FAFFLE KIT

Note : O : Applied, X : Not applied, : No relation


Filters are optional in some specific areas.
For Circuit Breaker Rating, please conform to local standards whenever necessary.
* With wind baffle accessory installed. with out wind baffle installed, the minimum temperature will be 14F D.B.

Inverter Single

10

Specifications

6RMI0-06A

Sales Model
Models
Cooling Capacity
Heating Capacity
Power Input
Running Current
Starting Current
Cooling COP
EER
SEER
HSPF
Power Supply
Power Factor
Air Flow Rate

Cooling/Heating
Cooling/Heating
Cooling/Heating

Indoor, Max/H/M/L
Outdoor,Max

Moisture Removal
Sound Level

Indoor,H/M/L
Outdoor,Max
Refrigerant & Charge (at 7.5 m/24.6 ft)
Additional Refrigerant charge
Compressor
Type
Model
Motor Type
Oil Type
Oil Charge
O.L.P. name
Fan(Indoor)
Type
Motor Output
Fan(Outdoor)
Type
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Power and Transmission Cable
Piping Connections
Liquid Side
Gas Side
Drain Hose(O.D / I.D.)
Dimensions
Indoor (W*H*D)
Outdoor (W*H*D)
Net Weight
Gross Weight
Operation Range
Piping Length (Min/Max)
Chargeless
Max. Elevation Difference
Tool Code(Chassis)
Functions

Indoor
Outdoor
Indoor
Outdoor
Cooling(Outdoor)
Heating(Outdoor)

Unit
kW
Btu/h.
kW
Btu/h.
W
A
A

/ V / Hz
%
m3/min(CFM)
m3/min(CFM)
l/h.(pts/hr)
dB(A)3
dB(A)3
g(oz)
g/m(oz/ft)

cc

W
A
No.*mm2(AWG)
No.*mm2(AWG)
mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
kg(lbs)
kg(lbs)
C()DB
C()WB
m(ft)
m(ft)
m(ft)

Indoor + Outdoor
Temperature Control
Allergy free filter
Plasma Filter
Prefilter(washable/anti-fungus)
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up& Down)
Airflow Direction Control(left & right)
Remote Controller Type
Setting Temperature
Cooling
Range
Heating
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Optional Function

LSN181HSV2/LSU181HSV2
AS-W183C2Y9
5.33
18,200
6.45
22,000
1,447 / 1,760
6.3 / 8.2
6.3 / 8.2
3.69
12.6
20.5
9.7
1/208-230/60
98.2
20.8(735)/17.6(622)/14.4(509)/11.3(399)
60(2,119)
2.6(5.5)
45 / 40 / 35
53
R410A, 1,800(63.5)
35(0.38)
Twin Rotary
GJT240DAA
Brushless DC Motor
PVE(FVC68D)
900
Cross Flow Fan
76.1
Propeller
BLDC
124
30
3*2.5(12)
4*1.0(18)
9.52(3/8)
15.88(5/8)
21.5 / 16.0(27/32 / 5/8)
1,030*325*245
40 9/16*12 13/16*9 11/16
870*800*320
34 1/4*31 1/2*12 19/32
14(30.9)
60(132.3)
18.2(40.1)
64(141.1)
-10(-18)*~48(14(0)*~118)
-15~24(5~75)
3(9.84) / 30(98.4)
7.5(24.6)
15(49.2)
SC + UE1+
Thermistor
O
O
O
O
6/6/6
Auto
Auto
Wireless Remote Controller
18(64.4)~ 30(86)
16(60.8)~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
O
WATER LEVEL SENSOR, WIND FAFFLE KIT

Note :
O : Applied, X : Not applied, : No relation
Filters are optional in some specific areas.
For Circuit Breaker Rating, please conform to local standards whenever necessary.
* With wind baffle accessory installed. with out wind baffle installed, the minimum temperature will be 14F D.B.

11

Inverter Single

LSN240HSV2/LSU240HSV2
AS-W243DGY9
6.45
22,000
8.09
27,600
1,760 / 2,380
7.9 / 10.7
7.9 / 10.7
3.66
12.5
18.9
10.2
1/208-230/60
96.9
25.0(883)/21.0(742)/17.8(629)/12.0(424)
60(2,119)
2.8(6.0)
46/43/39
54
R410A, 2,000(70.5)
35(0.38)
Twin Rotary
GJT240DAA
Brushless DC Motor
PVE(FVC68D)
900
Cross Flow Fan
76.1
Propeller
BLDC
124
30
3*2.5(12)
4*1.0(18)
9.52(3/8)
15.88(5/8)
21.5 / 16.0(27/32 / 5/8)
1209*346*205
47 19/32*13 5/8*8 1/16
870*800*320
34 1/4*31 1/2*12 19/32
15(33.1)
64(141.1)
20(44.1)
69(152.1)
-10(-18)*~48(14(0)*~118)
-15~24(5~75)
3(9.84)/30(98.4)
7.5(24.6)
15(49.2)
SD + UE1+
Thermistor
O
O
O
O
4/4/4
Auto
Auto
Wireless Remote Controller
18(64.4)~ 30(86)
16(60.8)~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
O
WATER LEVEL SENSOR, WIND FAFFLE KIT

6RMI0-06A

Specifications

Sales Model
Models
Cooling Capacity
Heating Capacity
Power Input
Running Current
Starting Current
Cooling COP
EER
SEER
HSPF
Power Supply
Power Factor
Air Flow Rate

Cooling/Heating
Cooling/Heating
Cooling/Heating

Indoor, Max/H/M/L
Outdoor,Max

Moisture Removal
Sound Level

Indoor,H/M/L
Outdoor,Max
Refrigerant & Charge (at 7.5 m/24.6 ft)
Additional Refrigerant charge
Compressor
Type
Model
Motor Type
Oil Type
Oil Charge
O.L.P. name
Fan(Indoor)
Type
Motor Output
Fan(Outdoor)
Type
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Power and Transmission Cable
Piping Connections
Liquid Side
Gas Side
Drain Hose(O.D / I.D.)
Dimensions
Indoor (W*H*D)
Outdoor (W*H*D)
Net Weight
Gross Weight
Operation Range
Piping Length (Min/Max)
Chargeless
Max. Elevation Difference
Tool Code(Chassis)
Functions

Indoor
Outdoor
Indoor
Outdoor
Cooling(Outdoor)
Heating(Outdoor)

Unit
kW
Btu/h.
kW
Btu/h.
W
A
A

/ V / Hz
%
m3/min(CFM)
m3/min(CFM)
l/h.(pts/hr)
dB(A)3
dB(A)3
g(oz)
g/m(oz/ft)

cc

W
A
No.*mm2(AWG)
No.*mm2(AWG)
mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
kg(lbs)
kg(lbs)
C()DB
C()WB
m(ft)
m(ft)
m(ft)

Indoor + Outdoor
Temperature Control
Allergy free filter
Plasma Filter
Prefilter(washable/anti-fungus)
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up& Down)
Airflow Direction Control(left & right)
Remote Controller Type
Setting Temperature
Cooling
Range
Heating
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Optional Function

LSN307HV2 / LSU307HV2
AS-W303DGY9
8.79
30,000
9.38
32,000
3,000 / 3,100
13.4/13.9
13.4/13.9
2.93
10.0
18.0
9.5
1/208-230/60
97.3
25.0(883)/21.8(770)/17.8(629)/12.0(424)
60(2,119)
4.8(9.5)
49/44/39
55
R410A, 2,000(70.5)
35(0.38)
Twin Rotary
GJT240DAA
Brushless DC Motor
PVE(FVC68D)
900
Cross Flow Fan
76.1
Propeller, Fan
BLDC
124
30
3*2.5(12)
4*1.0(18)
9.52(3/8)
15.88(5/8)
21.5 / 16.0(27/32 / 5/8)
1209*346*205
47 19/32*13 5/8*8 1/16
870*800*320
34 1/4*31 1/2*12 19/32
15(33.1)
64(141.1)
20(44.1)
69(152.1)
-10(-18)*~48(14(0)*~118)
-15~24(5~75)
3(9.84)/30(98.4)
7.5(24.6)
15(49.2)
SD + UE1+
Thermistor
O
O
O
O
4/4/4
Auto
Auto
Wireless Remote Controller
18(64.4)~ 30(86)
16(60.8)~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
O
WATER LEVEL SENSOR, WIND FAFFLE KIT

LSN360HV2 / LSU360HV2
AS-W363DGY9
9.67
33,000
10.32
35,200
4,035 / 3,840
17.0/16.2
17.0/16.2
2.4
8.2
16.1
9.9
1/208-230/60
98.2
25.0(883)/22.5(795)/17.8(629)/12.0(424)
60(2,119)
4.8(10.6)
49/44/39
55
R410A, 2,000(70.5)
35(0.38)
Twin Rotary
GJT240DAA
Brushless DC Motor
PVE(FVC68D)
900
Cross Flow Fan
76.1
Propeller, Fan
BLDC
124
30
3*2.5(12)
4*1.0(18)
9.52(3/8)
15.88(5/8)
21.5 / 16.0(27/32 / 5/8)
1209*346*205
47 19/32*13 5/8*8 1/16
870*800*320
34 1/4*31 1/2*12 19/32
15(33.1)
64(141.1)
20(44.1)
69(152.1)
-10(-18)*~48(14(0)*~118)
-15~24(5~75) )
3(9.84)/30(98.4)
7.5(24.6)
15(49.2)
SD + UE1+
Thermistor
O
O
O
O
4/4/4
Auto
Auto
Wireless Remote Controller
18(64.4)~ 30(86)
16(60.8)~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
O
WATER LEVEL SENSOR, WIND FAFFLE KIT

Note :
O : Applied, X : Not applied, : No relation
Filters are optional in some specific areas.
For Circuit Breaker Rating, please conform to local standards whenever necessary.
* With wind baffle accessory installed. with out wind baffle installed, the minimum temperature will be 14F D.B.

Inverter Single

12

Specifications

6RMI0-06A

Art Cool Mirror Inverter


Sales Model
Models
Cooling Capacity
Heating Capacity
Power Input
Running Current
Starting Current
Cooling COP
EER
SEER
HSPF
Power Supply
Power Factor
Air Flow Rate

Cooling/Heating
Cooling/Heating
Cooling/Heating

Indoor, Max/H/M/L
Outdoor,Max

Moisture Removal
Sound Level

Indoor,H/M/L
Outdoor,Max
Refrigerant & Charge (at 7.5 m/24.6 ft)
Additional Refrigerant charge
Compressor
Type
Model
Motor Type
Oil Type
Oil Charge
O.L.P. name
Fan(Indoor)
Type
Motor Output
Fan(Outdoor)
Type
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Power and Transmission Cable
Piping Connections
Liquid Side
Gas Side
Drain Hose(O.D / I.D.)
Dimensions
Indoor (W*H*D)
Outdoor (W*H*D)
Net Weight
Gross Weight
Operation Range
Piping Length (Min/Max)
Chargeless
Max. Elevation Difference
Tool Code(Chassis)
Functions

Indoor
Outdoor
Indoor
Outdoor
Cooling(Outdoor)
Heating(Outdoor)

Unit
kW
Btu/h.
kW
Btu/h.
W
A
A

/ V / Hz
%
m3/min(CFM)
3
m /min(CFM)
l/h.(pts/hr)
dB(A)3
dB(A)3
g(oz)
g/m(oz/ft)

cc

W
A
No.*mm2(AWG)
No.*mm2(AWG)
mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
kg(lbs)
kg(lbs)
C()DB
C()WB
m(ft)
m(ft)
m(ft)

Indoor + Outdoor
Temperature Control
Allergy free filter
Plasma Filter
Prefilter(washable/anti-fungus)
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up& Down)
Airflow Direction Control(left & right)
Remote Controller Type
Setting Temperature
Cooling
Range
Heating
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Optional Function

LAN090HSV2/LAU090HSV2
AS-W093BRM9
2.64
9,000
3.17
10,800
677 / 700
3.0 /3.7
3.0 /3.7
3.90
13.3
20
11
1/208-230/60
97.1
12.0(423)/9.5(335)/7.7(272)/6.0(212)
33(1,165)
1.1(2.6)
38 / 33 / 24
45
R410A, 1,000(35.3)
20(0.22)
Rotary
5RS102XAA21
Brushless DC Motor
PVE(FV50S)
320
Cross Flow Fan
20
Propeller
BLDC
43
15
3*1.0(18)
4*1.0(18)
6.35(1/4)
9.52(3/8)
21.5 / 16.0(27/32 / 5/8)
885*285*205
34 13/16* 11 1/4* 8 1/16
770*545*288
30 5/16*21 1/2*11 5/16
11(24.3)
35(77.2)
13.5(29.7)
37(81.6)
-10~48(14~118)
-15~24(5~75)
2(6.6) / 20(65.6)
12.5(41.0)
10(32.8)
SB + UL2
Thermistor
O
O
O
O
6/6/6
Auto
Auto
Wireless Remote Controller
18(64.4)~ 30(86)
16(60.8)~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
O
WATER LEVEL SENSOR

Note:
O : Applied, X : Not applied, : No relation
Filters are optional in some specific areas.
For Circuit Breaker Rating, please conform to local standards whenever necessary.

13

Inverter Single

LAN120HSV2/LAU120HSV2
AS-W123BRM9
3.28
11,200
3.90
13,300
896 / 1,000
4.2 / 4.9
4.2 / 4.9
3.66
12.5
20
11
1/208-230/60
97.1
12.0(423)/10.0(353)/7.7(272)/6.0(212)
33(1,165)
1.3(3.0)
39 / 33 / 24
45
R410A, 1,000(35.3)
20(0.22)
Rotary
5RS102XAA21
Brushless DC Motor
PVE(FV50S)
320
Cross Flow Fan
20
Propeller
BLDC
43
15
3*1.0(18)
4*1.0(18)
6.35(1/4)
9.52(3/8)
21.5 / 16.0(27/32 / 5/8)
885*285*205
34 13/16* 11 1/4* 8 1/16
770*545*288
30 5/16*21 1/2*11 5/16
11(24.3)
35(77.2)
13.5(29.7)
37(81.6)
-10~48(14~118)
-15~24(5~75)
2(6.6)/20(65.6)
12.5(41.0)
10(32.8)
SB + UL2
Thermistor
O
O
O
O
6/6/6
Auto
Auto
Wireless Remote Controller
18(64.4)~ 30(86)
16(60.8)~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
O
WATER LEVEL SENSOR

6RMI0-06A

Specifications

Sales Model
Models
Cooling Capacity
Heating Capacity
Power Input
Running Current
Starting Current
Cooling COP
EER
SEER
HSPF
Power Supply
Power Factor
Air Flow Rate

Cooling/Heating
Cooling/Heating
Cooling/Heating

Indoor, Max/H/M/L
Outdoor,Max

Moisture Removal
Sound Level

Indoor,H/M/L
Outdoor,Max
Refrigerant & Charge (at 7.5 m/24.6 ft)
Additional Refrigerant charge
Compressor
Type
Model
Motor Type
Oil Type
Oil Charge
O.L.P. name
Fan(Indoor)
Type
Motor Output
Fan(Outdoor)
Type
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Power and Transmission Cable
Piping Connections
Liquid Side
Gas Side
Drain Hose(O.D / I.D.)
Dimensions
Indoor (W*H*D)
Outdoor (W*H*D)
Net Weight
Gross Weight
Operation Range
Piping Length (Min/Max)
Chargeless
Max. Elevation Difference
Tool Code(Chassis)
Functions

Indoor
Outdoor
Indoor
Outdoor
Cooling(Outdoor)
Heating(Outdoor)

Unit
kW
Btu/h.
kW
Btu/h.
W
A
A

/ V / Hz
%
m3/min(CFM)
3
m /min(CFM)
l/h.(pts/hr)
dB(A)3
dB(A)3
g(oz)
g/m(oz/ft)

cc

W
A
No.*mm2(AWG)
No.*mm2(AWG)
mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
kg(lbs)
kg(lbs)
C()DB
C()WB
m(ft)
m(ft)
m(ft)

Indoor + Outdoor
Temperature Control
Allergy free filter
Plasma Filter
Prefilter(washable/anti-fungus)
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up& Down)
Airflow Direction Control(left & right)
Remote Controller Type
Setting Temperature
Cooling
Range
Heating
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Optional Function

LAN180HSV2/LAU180HSV2
AS-W183CRM9
5.33
18,200
6.45
22,000
1,447 / 1,760
6.3 / 8.2
6.3 / 8.2
3.69
12.6
20.5
9.7
1/208-230/60
98.2
22.0(777)/17.6(622)/14.4(509)/11.3(399)
60(2,119)
2.6(5.5)
45 / 40 / 35
53
R410A, 1,800(63.5)
35(0.38)
Twin Rotary
GJT240DAA
Brushless DC Motor
PVE(FVC68D)
900
Cross Flow Fan
76.1
Propeller
BLDC
124
30
3*2.5(12)
4*1.0(18)
9.52(3/8)
15.88(5/8)
21.5 / 16.0(27/32 / 5/8)
1,030*325*245
40 9/16*12 13/16*9 11/16
870*800*320
34 1/4*31 1/2*12 19/32
17(37.5)
60(132.3)
19(41.9)
64(141.1)
-10~48(14~118)
-15~24(5~75)
3(9.84)/30(98.4)
7.5(24.6)
15(49.2)
SC + UE1+
Thermistor
O
O
O
O
6/6/6
Auto
Auto
Wireless Remote Controller
18(64.4)~ 30(86)
16(60.8)~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
O
WATER LEVEL SENSOR

LAN240HSV2/LAU240HSV2
AS-W243CRM9
6.45
22,000
8.09
27,600
2,040 / 2,670
7.9 / 10.7
7.9 / 10.7
3.16
10.8
20.0
10.0
1/208-230/60
98.2
22.0(777)/17.9(632)/14.9(526)/11.3(399)
60(2,119)
2.6(5.5)
45 / 40 / 35
53
R410A, 1,800(63.5)
35(0.38)
Twin Rotary
GJT240DAA
Brushless DC Motor
PVE(FVC68D)
900
Cross Flow Fan
76.1
Propeller
BLDC
124
30
3*2.5(12)
4*1.0(18)
9.52(3/8)
15.88(5/8)
21.5 / 16.0(27/32 / 5/8)
1,030*325*245
40 9/16*12 13/16*9 11/16
870*800*320
34 1/4*31 1/2*12 19/32
17(37.5)
60(132.3)
19(41.9)
64(141.1)
-10~48(14~118)
-15~24(5~75)
3(9.84)/30(98.4)
7.5(24.6)
15(49.2)
SC + UE1+
Thermistor
O
O
O
O
6/6/6
Auto
Auto
Wireless Remote Controller
18(64.4)~ 30(86)
16(60.8)~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
O
WATER LEVEL SENSOR

Note:
O : Applied, X : Not applied, : No relation
Filters are optional in some specific areas.
For Circuit Breaker Rating, please conform to local standards whenever necessary.

Inverter Single

14

Specifications

6RMI0-06A

Art Cool Premier Inverter


Sales Model
Models
Cooling Capacity
Heating Capacity
Power Input
Running Current
Starting Current
Cooling COP
EER
SEER
HSPF
Power Supply
Power Factor
Air Flow Rate

Cooling/Heating
Cooling/Heating
Cooling/Heating

Indoor, Max/H/M/L
Outdoor,Max

Moisture Removal
Sound Level

Indoor, H/M/L
Outdoor,Max
Refrigerant & Charge (at 7.5 m/24.6 ft)
Additional Refrigerant charge
Compressor
Type
Model
Motor Type
Oil Type
Oil Charge
O.L.P. name
Fan(Indoor)
Type
Motor Output
Fan(Outdoor)
Type
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Power and Transmission Cable
Piping Connections
Liquid Side
Gas Side
Drain Hose(O.D / I.D.)
Dimensions
Indoor (W*H*D)
Outdoor (W*H*D)
Net Weight
Gross Weight
Operation Range
Piping Length (Min/Max)
Chargeless
Max. Elevation Difference
Tool Code(Chassis)
Functions

Indoor
Outdoor
Indoor
Outdoor
Cooling(Outdoor)
Heating(Outdoor)

Unit
kW
Btu/h.
kW
Btu/h.
W
A
A

/ V / Hz
%
m3/min(CFM)
3
m /min(CFM)
l/h.(pts/hr)
dB(A)3
dB(A)3
g(oz)
g/m(oz/ft)

cc

W
A
No.*mm2(AWG)
No.*mm2(AWG)
mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
kg(lbs)
kg(lbs)
C()DB
C()WB
m(ft)
m(ft)
m(ft)

Indoor + Outdoor
Temperature Control
Allergy free filter
Plasma Filter
Prefilter(washable/anti-fungus)
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up& Down)
Airflow Direction Control(left & right)
Remote Controller Type
Setting Temperature
Cooling
Range
Heating
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Optional Function

LSN090HYV/LSU090HYV
AS-W093MMM9
2.63
9,000
3.22
11,000
550 / 740
2.5/3.4
2.5/3.4
4.81
16.4
28.0
12.0
1/208-230/60
98.7
15.5(547)/14.0(494)/11.8(417)/8.0(283)
33(1,165)
1.5(3.3)
39 / 34 / 26
51
R410A, 1,250(44.1)
20(0.22)
Twin Rotary
GKT128MAA
Brushless DC Motor
FVC68D
450
Cross Flow Fan
20
Propeller, Fan
BLDC
85
15
3*1.0(18)
4*1.0(18)
6.35(1/4)
9.52(3/8)
21.5 / 16.0(27/32 / 5/8)
875*295*235
34 7/16* 11 5/8* 9 1/4
870*655*320
34 1/4* 25 13/16* 12 19/32
11.5(25.3)
43(94.8)
13.0(28.6)
45(99.2)
-10~48(14~118)
-10~24(14~75)
3(9.84) / 15(49.2)
7.5(24.6)
7(22.9)
SM + UE
Thermistor
O
O
6/6/6
Auto
Auto
Wireless Remote Controller
18(64.4) ~ 30(86)
16(60.8) ~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
O
WATER LEVEL SENSOR

Note:
O : Applied, - : No relation
* For circuit breaker rating, please conform to local standards wherever necessary.

15

Inverter Single

LSN120HYV/LSU120HYV
AS-W123MMM9
3.51
12,000
3.98
13,600
850 / 960
3.8 / 4.3
3.8 / 4.3
4.13
14.1
26.0
11.5
1/208-230/60
97.7
15.5(547)/14.5(512)/11.8(417)/8.0(283)
33(1,165)
1.7(3.7)
39 / 34 / 26
51
R410A, 1,250(44.1)
20(0.22)
Twin Rotary
GKT128MAA
Brushless DC Motor
FVC68D
450
Cross Flow Fan
20
Propeller, Fan
BLDC
85
15
3*1.0(18)
4*1.0(18)
6.35(1/4)
9.52(3/8)
21.5 / 16.0(27/32 / 5/8)
875*295*235
34 7/16* 11 5/8* 9 1/4
870*655*320
34 1/4* 25 13/16* 12 19/32
11.5(25.3)
43(94.8)
13.0(28.6)
45(99.2)
-10~48(14~118)
-10~24(14~75)
3(9.84) / 15(49.2)
7.5(24.6)
7(22.9)
SM + UE
Thermistor
O
O
6/6/6
Auto
Auto
Wireless Remote Controller
18(64.4) ~ 30(86)
16(60.8) ~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
O
WATER LEVEL SENSOR

6RMI0-06A

Specifications

Art Cool Gallery Inverter


Sales Model
Models
Cooling Capacity
Heating Capacity
Power Input
Running Current
Starting Current

Cooling/Heating
Cooling/Heating
Cooling/Heating

Unit
kW
Btu/h.
kW
Btu/h.
W
A
A

Cooling COP
EER
SEER
HSPF
Power Supply
Power Factor
Air Flow Rate

Indoor, Max/H/M/L
Outdoor,Max

Moisture Removal
Sound Level

Indoor,H/M/L
Outdoor,Max

Refrigerant & Charge (at 7.5 m/24.6 ft)


Additional Refrigerant charge

Compressor

Fan(Indoor)
Fan(Outdoor)

Type
Model
Motor Type
Oil Type
Oil Charge
O.L.P. name
Type
Motor Output
Type
Motor Type
Motor Output

Circuit Breaker*
Power Supply Cable
Power and Transmission Cable
Piping Connections

Liquid Side
Gas Side
Indoor (W*H*D)

Dimensions
Outdoor (W*H*D)

Gross Weight
Operation Range
Piping Length (Min/Max)
Chargeless
Max. Elevation Difference
Tool Code(Chassis)

Functions

cc

W
A

No.*mm2(AWG)
No.*mm2(AWG)

Drain Hose(O.D / I.D.)

Net Weight

/ V / Hz
%
m3/min(CFM)
3
m /min(CFM)
l/h.(pts/hr)
dB(A)3
dB(A)3
g(oz)
g/m(oz/ft)

Indoor
Outdoor
Indoor
Outdoor
Cooling(Outdoor)
Heating(Outdoor)

Indoor + Outdoor
Temperature Control
Allergy free filter
Plasma Filter
Prefilter(washable/anti-fungus)
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up& Down)
Airflow Direction Control(left & right)
Remote Controller Type
Setting Temperature
Range
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Optional Function

mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
kg(lbs)
kg(lbs)
C()DB
C()WB
m(ft)
m(ft)
m(ft)

Cooling
Heating

LAN090HVP/LAU090HVP
AS-W093F2B2
2.64
9,000
3.17
10,800
720/850
3.3/3.8
3.3/3.8
3.66
12.5
16
8.2
1/208-230/60
95.6
10.5(370)/9.5(335)/8.8(311)/7.0(247)
33(1165)
1.2(2.54)
42 / 36 / 32
45
R410A, 1,000(35.3)
20(0.22)
Single Rotary
GA102MFB
Brushless DC Motor
FVC68D
310
Turbo Fan
14.7
Propeller
BLDC
43
15
3*1.0(18)
4*1.0(18)
6.35(1/4)
9.52(3/8)
21.5 / 16.0(27/32 / 5/8)
600*600*146
23 5/8* 23 5/8* 5 3/4
770*545*288
30 5/16*21 1/2*11 5/16
14(30.9)
35(77.2)
15(33.07)
37(81.6)
-10 ~ 48 (14 ~ 118)
-10 ~ 24 (14 ~ 75)
3(9.84) / 15(49.2)

LAN120HVP/LAU120HVP
AS-W123F2B2
3.28
11,200
3.90
13,300
933/1250
4.3/5.7
4.3/5.7
3.52
12
16
8.2
1/208-230/60
95.6
10.5(370)/9.8(346)/8.8(311)/7.0(247)
33(1165)
1.5(3.17)
42 / 36 / 32
45
R410A, 1,000(35.3)
20(0.22)
Single Rotary
GA102MFB
Brushless DC Motor
FVC68D
310
Turbo Fan
14.7
Propeller
BLDC
43
15
3*1.0(18)
4*1.0(18)
6.35(1/4)
9.52(3/8)
21.5 / 16.0(27/32 / 5/8)
600*600*146
23 5/8* 23 5/8* 5 3/4
770*545*288
30 5/16*21 1/2*11 5/16
14(30.9)
35(77.2)
15(33.07)
37(81.6)
-10 ~ 48 (14 ~ 118)
-10 ~ 24 (14 ~ 75)
3(9.84) / 15(49.2)

7.5(24.6)

7.5(24.6)

7(22.9)
SF + UL2
Thermistor
O
O
O

7(22.9)
SF + UL2
Thermistor
O
O
O

6/6/6

6/6/6

Auto
Auto
Wireless Remote Controller
18(64.4)~ 30(86)
16(60.8)~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
O

Auto
Auto
Wireless Remote Controller
18(64.4)~ 30(86)
16(60.8)~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
O

WATER LEVEL SENSOR

WATER LEVEL SENSOR

Note:
O : Applied, - : No relation
* For circuit breaker rating, please conform to local standards wherever necessary.

Inverter Single

16

Specifications

6RMI0-06A

Mega Inverter
Sales Model
Model

Unit
kW
Btu/h.
kW
Btu/h.
W
A
A

Cooling Capacity
HeatingCapacity
Power Input
Running Current
Starting Current
Cooling COP
EER
SEER
HSPF
Power Supply
Power Factor
Air Flow Rate

Cooling/Heating
Cooling/Heating
Cooling/Heating

/ V / Hz
%
m3/min(CFM)
3
m min(CFM)
l/h.(pts/hr)
dB(A)+3
dB(A)+3
g(oz)
g/m(oz/ft)

Indoor,Max/H/M/L
Outdoor,Max

Moisture Removal
Indoor,H/M/L
Outdoor,Max
Refrigerant & Charge (at 7.5 m/24.6 ft)
Additional Refrigerant Charge
Type
Model
Compressor
Motor Type
Oil Type
Oil Charge
Type
Fan(Indoor)
Motor Type
Motor Output
Type
Fan(outdoor)
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Power and Transmission Cable
Liquid Side
Piping Connections
Gas Side
Drain Hose(O.D / I.D.)
Sound Level

Indoor(W*H*D)
Dimension
Outdoor(W*H*D)
Net Weight
Gross Weight
Operation Range
Piping Length (Min/Max)
Chargeless
Max. Elevation Difference
Tool Code(Chassis)

Indoor
Outdoor
Indoor
Outdoor
Cooling(Outdoor)
Heating(Outdoor)

W
A
No.*mm2(AWG)
No.*mm2(AWG)
mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
kg(lbs)
kg(lbs)
()DB
()WB
m(ft)
m(ft)
m(ft)

Indoor + Outdoor
Temperature Control
Allergy free filter
Plasma Filter
Prefilter(washable/anti-fungus)
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up& Down)
Airflow Direction Control(left & right)
Remote Controller Type
Setting Temperature Range

Functions

cc

Auto Operation (Micom Control)


Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Special Function

Cooling
Heating

LSN090HEV/LSU090HEV
AS-W093WSA7
2.49
8,500
2.64
9,000
780/ 780
3.6/3.6
3.6/3.6
3.19
10.90
16.3
8.3
1/208-230/60
94
9(318)/8(276)/6(226)/5(177)
27(953)
1.0(2.12)
39 / 33 / 25
47
R410A, 750(26.5)
20(0.22)
Rotary
GA092MMA
Brushless DC Motor
FVC68D
310
Cross Flow Fan
BLDC
20
Propeller
AC
75
15
3*1.0(18)
4*1.0(18)
6.35(1/4)
9.52(3/8)
21.5 / 16.0(0.85 / 0.63)
756 x 265 x 184
29 3/4*10 7/16*7 1/4
717 x 483 x 230
28 1/4*19 1/32*9 1/16
7.2(15.9)
23.2(51.1)
9.1(20.1)
25.4(55.3)
18~48(64~118)
-5~24(23~75)
3 (9.8) / 15 (49.2)
7.5(24.6)
7(22.9)
SW + UA3+
Thermistor
O
O
O
4/4/4
Auto
Manual
Wireless Remote Controller
18(64.4)~ 30(86)
16(60.8)~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
WATER LEVEL SENSOR

Note : O : Applied, X : Not applied, : No relation


Filters are optional in some specific areas.
For Circuit Breaker Rating, please conform to local standards whenever necessary.

17

Inverter Single

LSN120HEV/LSU120HEV
AS-W123BSA7
3.52
12,000
3.52
12,000
1,170/980
5.2/4.4
5.2/4.4
3.00
10.26
16.3
8.5
1/208-230/60
95
12(424)/10(353)/8(272)/6(212)
27(953)
1.3(2.76)
39 / 33 / 25
47
R410A, 750(26.5)
20(0.22)
Rotary
GA092MAB
Brushless DC Motor
FVC68D
310
Cross Flow Fan
BLDC
20
Propeller
AC
75
15
3*1.0(18)
4*1.0(18)
6.35(1/4)
9.52(3/8)
21.5 / 16.0(0.85 / 0.63)
885 x 285 x 210
34 13/16*11 1/4* 8 1/4
717 x 483 x 230
28 1/4*19 1/32*9 1/16
9(19.8)
22.0(48.5)
11(24.2)
23.6(52.1)
18~48(64~118)
-5~24(23~75)
3 (9.8) / 15 (49.2)
7.5(24.6)
7(22.9)
SB + UA3+
Thermistor
O
O
O
4/4/4
Auto
Manual
Wireless Remote Controller
18(64.4)~ 30(86)
16(60.8)~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
WATER LEVEL SENSOR

6RMI0-06A

Specifications

Sales Model
Model

Unit
kW
Btu/h.
kW
Btu/h.
W
A
A

Cooling Capacity
HeatingCapacity
Power Input
Running Current
Starting Current
Cooling COP
EER
SEER
HSPF
Power Supply
Power Factor
Air Flow Rate

Cooling/Heating
Cooling/Heating
Cooling/Heating

/ V / Hz
%
m3/min(CFM)
m3min(CFM)
l/h.(pts/hr)
dB(A)+3
dB(A)+3
g(oz)
g/m(oz/ft)

Indoor,Max/H/M/L
Outdoor,Max

Moisture Removal
Indoor,H/M/L
Outdoor,Max
Refrigerant & Charge (at 7.5 m/24.6 ft)
Additional Refrigerant Charge
Type
Model
Compressor
Motor Type
Oil Type
Oil Charge
Type
Fan(Indoor)
Motor Type
Motor Output
Type
Fan(outdoor)
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Power and Transmission Cable
Liquid Side
Piping Connections
Gas Side
Drain Hose(O.D / I.D.)
Sound Level

Indoor(W*H*D)
Dimension
Outdoor(W*H*D)
Net Weight
Gross Weight
Operation Range
Piping Length (Min/Max)
Chargeless
Max. Elevation Difference
Tool Code(Chassis)

Indoor
Outdoor
Indoor
Outdoor
Cooling(Outdoor)
Heating(Outdoor)

W
A
No.*mm2(AWG)
No.*mm2(AWG)
mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
kg(lbs)
kg(lbs)
()DB
()WB
m(ft)
m(ft)
m(ft)

Indoor + Outdoor
Temperature Control
Allergy free filter
Plasma Filter
Prefilter(washable/anti-fungus)
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up& Down)
Airflow Direction Control(left & right)
Remote Controller Type
Setting Temperature Range

Functions

cc

Auto Operation (Micom Control)


Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Special Function

Cooling
Heating

LSN180HEV/LSU180HEV
AS-W183CSA7
4.98
17,000
5.57
19,000
1,550 / 1,590
7.2 / 7.1
7.2 / 7.1
3.21
10.95
17.0
8.7
1/208-230/60
93.6
18(629)/14(512)/12(441)/10(353)
38 (1342)
1.6(3.39)
42 / 40 / 35
51
R410A, 1,060(37.4)
30(0.33)
Twin Rotary
GKT141MBA
Brushless DC Motor
FVC68D
470
Cross Flow Fan
BLDC
30
Propeller
BLDC
43
20
3*1.0(18)
4*1.0(18)
6.35(1/4)
12.7(1/2)
21.5 / 16.0(0.85 / 0.63)
1,030*325*250
40 9/16*12 13/16*9 13/16
770*545*288
30 5/16*21 1/2*11 5/16
12.4(27.3)
32.4(71.4)
13.4(29.5)
34.5(76.1)
18~48(64~118)
-5~24(23~75)
3(9.8)/20(65.6)
7.5(24.6)
10(32.8)
SC + UL2
Thermistor
O
O
O
4/4/4
Auto
Manual
Wireless Remote Controller
18(64.4)~ 30(86)
16(60.8)~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
WATER LEVEL SENSOR

LSN240HEV/LSU240HEV
AS-W243CSA7
6.45
22,000
6.45
22,000
2,045 / 1,935
9.1 / 8.7
9.1 / 8.7
3.15
10.75
17.0
8.5
1/208-230/60
95
20(689)/17(600)/14(494)/11(388)
50(1,766)
2.3(4.88)
45 / 40 / 35
53
R410A, 1,170(41.3)
30(0.33)
Twin Rotary
GKT176MF
Brushless DC Motor
FVC68D
470
Cross Flow Fan
BLDC
30
Propeller
BLDC
124
20
3*1.5(16)
4*1.0(18)
6.35(1/4)
15.88(5/8)
21.5 / 16.0(0.85 / 0.63)
1,030*325*250
40 9/16*12 13/16*9 13/16
870*655*320
34 1/4*25 13/16*12 19/32
12.6(27.8)
41.7(91.9)
15(33.1)
47(103.6)
18~48(64~118)
-5~24(23~75)
3(9.8)/20(65.6)
7.5(24.6)
10(32.8)
SC + UE
Thermistor
O
O
O
4/4/4
Auto
Manual
Wireless Remote Controller
18(64.4)~ 30(86)
16(60.8)~ 30(86)
O
O
24h, On/Off
O
O
3
O
O
O
WATER LEVEL SENSOR

Note : O : Applied, X : Not applied, : No relation


Filters are optional in some specific areas.
For Circuit Breaker Rating, please conform to local standards whenever necessary.

Inverter Single

18

Specifications

6RMI0-06A

Art Cool Premier Inverter


Sales Model
Models

Unit
kW
Btu/h.
kW
Btu/h.
W
A
A

Cooling Capacity
Heating Capacity
Power Input
Running Current
Starting Current
Cooling COP
EER
SEER
HSPF
Power Supply
Power Factor
Air Flow Rate

Cooling/Heating
Cooling/Heating
Cooling/Heating

/ V / Hz
%
m3/min(CFM)
3
m /min(CFM)
l/h.
dB(A)3
dB(A)3
g(oz)
g/m(oz/ft)

Indoor (Max/H/M/L)
Outdoor,Max

Moisture Removal
Indoor,H/M/L
Outdoor,Max
Refrigerant & Charge (at 7.5 m/24.6 ft)
Additional Refrigerant charge
Type
Model
Motor Type
Compressor
Oil Type
Oil Charge
O.L.P. name
Type
Fan(Indoor)
Motor Output
Type
Fan(Outdoor)
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Power and Transmission Cable
Liquid Side
Piping Connections
Gas Side
Drain Hose(O.D / I.D.)
Sound Level

Indoor (W*H*D)
Dimensions
Outdoor (W*H*D)
Net Weight
Gross Weight
Operation Range
Piping Length (Min/Max)
Chargeless
Max. Elevation Difference
Tool Code(Chassis)

Functions

Indoor
Outdoor
Indoor
Outdoor
Cooling(Outdoor)
Heating(Outdoor)

cc

W
A
No.*mm2 (AWG)
No.*mm2 (AWG)
mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
kg(lbs)
kg(lbs)
C()DB
C()WB
m(ft)
m(ft)
m(ft)

Indoor + Outdoor
Temperature Control
Allergy free filter
Plasma Filter + 2G NPI
Prefilter(washable/anti-fungus)
3M HAF Filter
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up& Down)
Airflow Direction Control(left & right)
Remote Controller Type
Setting Temperature
Range
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Special Function

Cooling
Heating

LAN090HYV/LAU090HYV
AS-W093MMB8
2.64
9,000
3.22
11,000
562/700
2.7/3.2
2.7/3.2
4.69
16.01
27.5
11.8
1/208-230/60
94
15.5(547)/14.0(494)/11.8(417)/8.0(283)
33(1,165)
1.5(3.3)
42 / 36 / 25
45
R410A, 1,150(40.6)
20(0.22)
Twin Rotary
DA128A1F
Brushless DC Motor
VG74
450
Cross Flow Fan
20
Propeller, Fan
BLDC
43
15
3*1.0(18)
4*1.0(18)
6.35(1/4)
9.52(3/8)
21.5 / 16.0 (27/32 / 5/8)
875*295*235
34 7/16* 11 5/8* 9 1/4
770*545*288
30 5/16*21 1/2*11 5/16
11.0(24.25)
33(72.75)
13.0(28.6)
35(77.16)
-10~48(14~118)
-25~24(-13~75)
2(6.6) / 20(65.6)
12.5(41.0)
10(32.8)
SM + UL2
Thermistor
O
O
O
O
6/6/6
Auto
Auto
Better
18C ~ 30C(64.4~86)
16C ~ 30C(60.8~86)
O
O
24h, On/Off
O
O
3
O
O
O
O
WLAN, Water Level sensor, Cooling Only switch

Note : O : Applied, X : Not applied, : No relation


Filters are optional in some specific areas.
For Circuit Breaker Rating, please conform to local standards whenever necessary.
If you use WLAN, WLAN module must be purchased separately

19

Inverter Single

LAN120HYV/LAU120HYV
AS-W123MMB8
3.51
12,000
3.98
13,600
850/860
3.9/4.0
3.9/4.0
4.14
14.12
25.5
11.5
1/208-230/60
95
15.5(547)/14.0(494)/11.8(417)/8.0(283)
33(1,165)
1.7(3.7)
42 / 36 / 25
45
R410A, 1,150(40.6)
20(0.22)
Twin Rotary
DA128A1F
Brushless DC Motor
VG74
450
Cross Flow Fan
20
Propeller, Fan
BLDC
43
15
3*1.0(18)
4*1.0(18)
6.35(1/4)
9.52(3/8)
21.5 / 16.0 (27/32 / 5/8)
875*295*235
34 7/16* 11 5/8* 9 1/4
770*545*288
30 5/16*21 1/2*11 5/16
11.0(24.25)
33(72.75)
13.0(28.6)
35(77.16)
-10~48(14~118)
-25~24(-13~75)
2(6.6) / 20(65.6)
12.5(41.0)
10(32.8)
SM + UL2
Thermistor
O
O
O
O
6/6/6
Auto
Auto
Better
18C ~ 30C(64.4~86)
16C ~ 30C(60.8~86)
O
O
24h, On/Off
O
O
3
O
O
O
O
WLAN, Water Level sensor, Cooling Only switch

6RMI0-06A

Specifications

Wall Mount Inverter


Sales Model
Models
Cooling Capacity
Heating Capacity
Power Input
Running Current
Starting Current
Cooling COP
EER
SEER
HSPF
Power Supply
Power Factor
Air Flow Rate

Cooling/Heating
Cooling/Heating
Cooling/Heating

Indoor (Max/H/M/L)
Outdoor,Max

Moisture Removal
Indoor, H/M/L
Outdoor,Max
Refrigerant & Charge (at 7.5 m/24.6ft)
Additional Refrigerant charge
Type
Model
Motor Type
Compressor
Oil Type
Oil Charge
O.L.P. name
Type
Fan(Indoor)
Motor Output
Type
Fan(Outdoor)
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Power and Transmission Cable
Liquid Side
Piping Connections
Gas Side
Drain Hose(O.D / I.D.)
Sound Level

Indoor (W*H*D)
Dimensions
Outdoor (W*H*D)

Unit
kW
Btu/h.
kW
Btu/h.
W
A
A

/ V / Hz
%
m3/min(CFM)
m3/min(CFM)
l/h.
dB(A)3
dB(A)3
g(oz)
g/m(oz/ft)

cc

W
A
No.*mm2 (AWG)
No.*mm2 (AWG)
mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
kg(lbs)
kg(lbs)
C()DB
C()WB
m(ft)
m(ft)
m(ft)

Indoor
Net Weight
Outdoor
Indoor
Gross Weight
Outdoor
Cooling(Outdoor)
Operation Range
Heating(Outdoor)
Piping Length (Min/Max)
Chargeless
Max. Elevation Difference
Tool Code(Chassis) Indoor + Outdoor
Temperature Control
Allergy free filter
Plasma Filter
Prefilter(washable/anti-fungus)
3M HAF Filter
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(Up& Down)
Airflow Direction Control(Left & Right)
Remote Controller Type
Cooling
Setting Temperature
Range
Functions
Heating
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Special Function

LSN091HSV3/LSU091HSV3
AS-W093B1B8
2.64
9,000
3.17
10,800
677 / 700
3.0 /3.7
3.0 /3.7
3.90
13.3
21.5
11.0
1/208-230/60
93
11.0(388)/9.5(335)/7.7(272)/6.0(212)
33(1,165)
1.1(2.6)
38 / 33 / 24
45
R410A, 1,000(35.3)
20(0.22)
Single Rotary
GA102MFB
Brushless DC Motor
PVE(FVC68D)
310
Cross Flow Fan
20
Propeller
BLDC
43
15
3*1.0(18)
4*1.0(18)
6.35(1/4)
9.52(3/8)
21.5 / 16.0(27/32 / 5/8)
885*285*210
34 13/16* 11 1/4* 8 1/4
770*545*288
30 5/16*21 1/2*11 5/16
10.2(22.5)
34(75)
12.4(27.3)
35.8(78.9)
-10(-18)*~47.8(14(0)*~118)
-20~23.9(-4~75)
2(6.6) / 20(65.6)
12.5(41.0)
10(32.8)
SB + UL2
Thermistor
O
O
O
O
6/6/6
Auto
Auto
Wireless LCD
18C ~ 30C(64.4~86)
16C ~ 30C(60.8~86)
O
O
24h, On/Off
O
O
3
O
O
O
O
WLAN, Water Level sensor, Cooling Only switch, Wind Baffle Kit

Note : O : Applied, X : Not applied, : No relation


Filters are optional in some specific areas.
For Circuit Breaker Rating, please conform to local standards whenever necessary.

LSN121HSV3/LSU121HSV3
LSN181HSV3/LSU181HSV3
AS-W123B1B8
AS-W183C2B8
3.28
5.33
11,200
18,200
3.90
6.45
13,300
22,000
896 / 1,000
1,447 / 1,760
4.2 / 4.9
6.3 / 8.2
4.2 / 4.9
6.3 / 8.2
3.66
3.69
12.5
12.6
21.5
20.5
11.0
9.7
1/208-230/60
1/208-230/60
97.1
98.2
12.0(423)/10.0(353)/7.7(272)/6.0(212)
20.8(735)/17.6(622)/14.4(509)/11.3(399)
33(1,165)
60(2,119)
1.3(3.0)
2.6(5.5)
39 / 33 / 24
45 / 40 / 35
45
53
R410A, 1,000(35.3)
R410A, 1,800(63.5)
20(0.22)
35(0.38)
Single Rotary
Twin Rotary
GA102MFB
GJT240MBA
Brushless DC Motor
Brushless DC Motor
PVE(FVC68D)
PVE(FVC68D)
310
900
Cross Flow Fan
Cross Flow Fan
20
76.1
Propeller
Propeller
BLDC
BLDC
43
124
15
25
3*1.0(18)
3*2.5(12)
4*1.0(18)
4*1.0(18)
6.35(1/4)
9.52(3/8)
9.52(3/8)
15.88(5/8)
21.5 / 16.0(27/32 / 5/8)
21.5 / 16.0(27/32 / 5/8)
885*285*210
1,030*325*245
34 13/16* 11 1/4* 8 1/4
40 9/16*12 13/16*9 11/16
770*545*288
870*800*320
30 5/16*21 1/2*11 5/16
34 1/4*31 1/2*12 19/32
10.2(22.5)
14.5(31.96)
34(75)
55.5(122.35)
12.4(27.3)
18.2(40.1)
35.8(78.9)
59.0(130.07)
-10(-18)*~47.8(14(0)*~118)
-10(-18)*~47.8(14(0)*~118)
-20~23.9(-4~75)
-20~23.9(-4~75)
2(6.6) / 20(65.6)
3(9.84) / 30(98.4)
12.5(41.0)
7.5(24.6)
10(32.8)
15(49.2)
SB + UL2
SC + UE1+
Thermistor
Thermistor
O
O
O
O
O
O
O
O
6/6/6
6/6/6
Auto
Auto
Auto
Auto
Wireless LCD
Wireless LCD
18C ~ 30C(64.4~86)
18C ~ 30C(64.4~86)
16C ~ 30C(60.8~86)
16C ~ 30C(60.8~86)
O
O
O
O
24h, On/Off
24h, On/Off
O
O
O
O
3
3
O
O
O
O
O
O
O
O
WLAN, Water Level sensor, Cooling Only switch, Wind Baffle Kit WLAN, Water Level sensor, Cooling Only switch, Wind Baffle Kit

If you use WLAN, WLAN module must be purchased separately


With wind baffle accessory installed. with out wind baffle installed, the minimum
temperature will be 14F D.B.

Inverter Single

20

Specifications

6RMI0-06A

Sales Model
Models
Cooling Capacity
Heating Capacity
Power Input
Running Current
Starting Current
Cooling COP
EER
SEER
HSPF
Power Supply
Power Factor
Air Flow Rate

Cooling/Heating
Cooling/Heating
Cooling/Heating

Indoor (Max/H/M/L)
Outdoor,Max

Moisture Removal
Indoor, H/M/L
Outdoor,Max
Refrigerant & Charge (at 7.5 m/24.6ft)
Additional Refrigerant charge
Type
Model
Motor Type
Compressor
Oil Type
Oil Charge
O.L.P. name
Type
Fan(Indoor)
Motor Output
Type
Fan(Outdoor)
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Power and Transmission Cable
Liquid Side
Piping Connections
Gas Side
Drain Hose(O.D / I.D.)
Sound Level

Indoor (W*H*D)
Dimensions
Outdoor (W*H*D)

Unit
kW
Btu/h.
kW
Btu/h.
W
A
A

/ V / Hz
%
m3/min(CFM)
3
m /min(CFM)
l/h.
dB(A)3
dB(A)3
g(oz)
g/m(oz/ft)

cc

W
A
No.*mm2 (AWG)
No.*mm2 (AWG)
mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
kg(lbs)
kg(lbs)
C()DB
C()WB
m(ft)
m(ft)
m(ft)

Indoor
Net Weight
Outdoor
Indoor
Gross Weight
Outdoor
Cooling(Outdoor)
Operation Range
Heating(Outdoor)
Piping Length (Min/Max)
Chargeless
Max. Elevation Difference
Tool Code(Chassis) Indoor + Outdoor
Temperature Control
Allergy free filter
Plasma Filter
Prefilter(washable/anti-fungus)
3M HAF Filter
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(Up& Down)
Airflow Direction Control(Left & Right)
Remote Controller Type
Cooling
Setting Temperature
Range
Functions
Heating
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Special Function

LSN240HSV3/LSU240HSV3
AS-W243D8B8
6.45
22,000
8.09
27,600
1,760 / 2,380
7.9 / 10.7
7.9 / 10.7
3.66
12.5
20.0
10.2
1/208-230/60
96.9
25.0(883)/21.0(742)/17.8(629)/12.0(424)
60(2,119)
2.8(6.0)
46/43/39
54
R410A, 2,000(70.5)
35(0.38)
Twin Rotary
GJT240MBA
Brushless DC Motor
PVE(FVC68D)
900
Cross Flow Fan
76.1
Propeller
BLDC
124
25
3*2.5 (12)
4*1.0 (18)
9.52(3/8)
15.88(5/8)
21.5 / 16.0(27/32 / 5/8)
1209*346*205
47 19/32*13 5/8*8 1/16
870*800*320
34 1/4*31 1/2*12 19/32
16.1(35.5)
58.0(127.8)
18.9(41.7)
62.0(136.7)
-10(-18)*~47.8(14(0)*~118)
-20~23.9(-4~75)
3(9.84) / 30(98.4)
7.5(24.6)
15(49.2)
SD + UE1+
Thermistor
O
O
O
O
4/4/4
Auto
Auto
Wireless LCD
18C ~ 30C(64.4~86)
16C ~ 30C(60.8~86)
O
O
24h, On/Off
O
O
3
O
O
O
O
WLAN, Water Level sensor, Cooling Only switch, Wind Baffle Kit

Note : O : Applied, X : Not applied, : No relation


Filters are optional in some specific areas.
For Circuit Breaker Rating, please conform to local standards whenever necessary.

21

LSN307HV3/LSU307HV3
LSN360HV3/LSU360HV3
AS-W303D8B8
AS-W363D8B8
8.79
9.67
30,000
33,000
9.38
10.32
32,000
35,200
3,000 / 3,100
4,035 / 3,840
13.4/13.9
17.0/16.2
13.4/13.9
17.0/16.2
2.93
2.4
10.0
8.2
18.0
16.1
9.5
9.9
1/208-230/60
1/208-230/60
97.3
98.2
25.0(883)/21.8(770)/17.8(629)/12.0(424)
25.0(883)/22.5(795)/17.8(629)/12.0(424)
60(2,119)
60(2,119)
4.8(10.6)
4.8(10.6)
49/44/39
49/44/39
55
55
R410A, 2,000(70.5)
R410A, 2,000(70.5)
35(0.38)
35(0.38)
Twin Rotary
Twin Rotary
GJT240MBA
GJT240MBA
Brushless DC Motor
Brushless DC Motor
PVE(FVC68D)
PVE(FVC68D)
900
900
Cross Flow Fan
Cross Flow Fan
76.1
76.1
Propeller, Fan
Propeller, Fan
BLDC
BLDC
124
124
25
25
3*2.5 (12)
3*2.5 (12)
4*1.0 (18)
4*1.0 (18)
9.52(3/8)
9.52(3/8)
15.88(5/8)
15.88(5/8)
21.5 / 16.0(27/32 / 5/8)
21.5 / 16.0(27/32 / 5/8)
1209*346*205
1209*346*205
47 19/32*13 5/8*8 1/16
47 19/32*13 5/8*8 1/16
870*800*320
870*800*320
34 1/4*31 1/2*12 19/32
34 1/4*31 1/2*12 19/32
16.1(35.5)
16.1(35.5)
58.0(127.8)
58.0(127.8)
18.9(41.7)
18.9(41.7)
62.0(136.7)
62.0(136.7)
-10(-18)*~47.8(14(0)*~118)
-10(-18)*~47.8(14(0)*~118)
-20~23.9(-4~75)
-20~23.9(-4~75)
3(9.84) / 30(98.4)
3(9.84) / 30(98.4)
7.5(24.6)
7.5(24.6)
15(49.2)
15(49.2)
SD + UE1+
SD + UE1+
Thermistor
Thermistor
O
O
O
O
O
O
O
O
4/4/4
4/4/4
Auto
Auto
Auto
Auto
Wireless LCD
Wireless LCD
18C ~ 30C(64.4~86)
18C ~ 30C(64.4~86)
16C ~ 30C(60.8~86)
16C ~ 30C(60.8~86)
O
O
O
O
24h, On/Off
24h, On/Off
O
O
O
O
3
3
O
O
O
O
O
O
O
O
WLAN, Water Level sensor, Cooling Only switch, Wind Baffle Kit WLAN, Water Level sensor, Cooling Only switch, Wind Baffle Kit

If you use WLAN, WLAN module must be purchased separately


With wind baffle accessory installed. with out wind baffle installed, the minimum
temperature will be 14F D.B.

Inverter Single

55(2 5/32)

Left rear piping

50(1 31/32)

Inverter Single

175(6 29/32)

123(4 13/16)

65(2 9/16)

Unit Outline
434(17)

Installation Plate
5

Place a level on raised tab

875(34 7/16)

55(2 5/32)

[Unit : mm(inch)]

Right rear piping

65(2 9/16)

295(11 5/8)
217(8 17/32)

170(6 11/16)

439(17 5/16)

50(1 31/32)

235(9 1/4)

CHASSIS CODE : SM

LSN090HYV / LSN120HYV
LAN090HYV / LAN120HYV

6RMI0-06A
Specifications

4. Dimensional drawings
4.1 Indoor Units

22

Unit Outline

Inverter Single

192(7 9/16)

145(5 11/16)

378(14 7/8)

(Unit : in)

Installation Plate

378(14 7/8)

Place a level on raised tab

756(29 3/4)

265(10 7/16)
192(7 9/16)

75(2 15/16)

65(2 9/16)

Right rear piping

23

65(2 9/16)

[Unit: mm (inch)]

184(7 1/4)

CHASSIS CODE : SW

LSN090HEV

Dimensional drawings
6RMI0-06A

Left rear piping

Inverter Single
412(16 1/4)

178(7)

Left Rear
Piping
136(5 1/4)

65(2 9/16)

Unit Outline

285(11 1/4)
65(2 9/16)

245(9 5/8)

Right Rear
Piping
123(4 13/16)

480(18 7/8)

(Unit : in)

Installation Plate

Place a level on raised tab

885(34 13/16)

[Unit: mm (inch)]

210(8 1/4)

CHASSIS CODE : SB

LSN120HEV

6RMI0-06A
Dimensional drawings

24

Left rear piping

Unit Outline

Inverter Single

175(6 29/32)

133(5 3/16)

Installation Plate

442(17 13/32)

Place a level on raised tab

217(8 1/2)

95(3 11/16)

[Unit: mm (inch)]

210(8 1/4)

Right rear piping

59.5(2 5/16)

23(29/32)

70(2 3/4)

159.5(6 5/16)

442(17 13/32)

210(8 1/4)

285(11 1/4)

25

70(2 3/4)

885(34 13/16)

CHASSIS CODE : SB

LSN091HSV2 / LSN121HSV2
LSN091HSV3 / LSN121HSV3

Dimensional drawings
6RMI0-06A

Inverter Single

Left rear piping

45(1 3/4)
55(2 5/32)

133(5 3/16)

Unit Outline

175(6 29/32)

65

442(17 13/32)

Installation Plate
5

Place a level on raised tab

885(34 13/16)

285(11 1/4)
70(2 3/4)

217(8 1/2)

95(3 11/16)

442(17 13/32)

45(1 3/4)

50(1 31/32)

[Unit: mm (inch)]

Right rear piping

205(8 1/16)

CHASSIS CODE : SB

LAN090HSV2
LAN120HSV2

6RMI0-06A
Dimensional drawings

26

60(2 13/32)

Inverter Single

105(4 3/32)

69(2 11/16)

460(18 3/32)

Measuring Tape
Hanger

Measuring Tape

Installation Plate

Place a level on raised tab

207(8 3/32)

Right rear
piping

70(2 13/16)

56(2 3/16)

570(22 13/32)

245(9 11/16)
325(12 13/16)

27

Left rear
piping

70(2 13/16)

Unit Outline

1030(40 9/16)

[Unit: mm (inch)]

245(9 11/16)

CHASSIS CODE : SC

LSN181HSV2
LSN181HSV3

Dimensional drawings
6RMI0-06A

Inverter Single

105(4 3/32)

Left rear
piping
69(2 11/16)

70(2 3/4)

46(1 13/16)
64(2 17/32)

Unit Outline

Measuring Tape
Hanger

Measuring Tape

Installation Plate

460(18 3/32)

Place a level on raised tab

1030(40 9/16)

Right rear
piping
56(2 3/16)

70(2 3/4)

(Unit : mm)

207(8 3/32)

570(22 13/32)

46(1 13/16)

52(2 1/32)

[Unit: mm (inch)]

245(9 11/16)

CHASSIS CODE : SC

LAN180HSV2
LAN240HSV2

6RMI0-06A
Dimensional drawings

28

325(12 13/16)

52(2 1/32)

29

Inverter Single

Left rear
piping

70(2 13/16)

105(4 3/32)

69(2 11/16)

Unit Outline
460(18 3/32)

Measuring Tape
Hanger

Measuring Tape

Installation Plate

Place a level on raised tab

207(8 3/32)

Right rear
piping

70(2 13/16)

56(2 3/16)

570(22 13/32)

[Unit: mm (inch)]
CHASSIS CODE : SC

LSN180HEV
LSN240HEV

Dimensional drawings
6RMI0-06A

Inverter Single
858(33 13/16)

780(30 11/16)

60(2 13/32)
210(8 5/16)

335(13 3/16)

1209(47 19/32)

346(13 5/8)
65(2 19/32)

[Unit: mm (inch)]

205(8 1/16)

60(2 13/32)

CHASSIS CODE : SD

LSN240HSV2
LSN307HV2
LSN360HV2

6RMI0-06A
Dimensional drawings

30

60(2 13/32)

31

Inverter Single
858(33 13/16)

780(30 11/16)

[Unit: mm (inch)]

CHASSIS CODE : SD

LSN240HSV3
LSN307HV3
LSN360HV3

Dimensional drawings
6RMI0-06A

335(13 3/16)

600(23 5/8)

76(3)

146(5 3/4)

[Unit: mm (inch)]

499(19 21/32)

CHASSIS CODE : SF

For pipe and cable

LAN090HVP
LAN120HVP

6RMI0-06A
Dimensional drawings

Inverter Single

32

43(1 11/16)

88(3 15/32)

48(1 7/8)

600(23 5/8)

277(10 29/32)

558(22)

464(18 5/16)

106(4 3/16)

353(13 29/32)

54(2 3/32)

154(6 3/32)
70(2 13/16)

33

Inverter Single
207(8 3/32)

770(30 5/16)

[Unit: mm (inch)]

288(11 5/16)

LAU090HYV
LSU091HSV3
LAU120HYV
LSU121HSV3

CHASSIS CODE : UL2

LAU090HSV2
LAU120HSV2
LSU091HSV2
LSU121HSV2
LAU090HVP
LAU120HVP
LSU180HEV

Dimensional drawings
6RMI0-06A

4.2 Outdoor Units

267(10 1/2)

530(20 29/32)

545 (21 1/2)

301(11 29/32)

531(20 29/32)

546(21 1/2)

319(12 19/32)

630(24 13/16)

655(25 13/16)

55(2 3/16)

160(6 5/16)

360(14 3/16)
79(3 3/32)

870(34 1/4)

[Unit: mm (inch)]

320(12 19/32)

CHASSIS CODE : UE

LSU090HYV
LSU120HYV
LSU240HEV

6RMI0-06A
Dimensional drawings

Inverter Single

34

76(3)

320(12 19/32)

800(31 1/2)
783(30 13/16)

35

333(13 3/32)

531(20 29/32)

546(21 1/2)

870(34 1/4)

55(2 3/16)

160(6 5/16)

360(14 3/16)
50(2)

[Unit: mm (inch)]

320(12 19/32)

Item No.
1
2
3
4
5
6

CHASSIS CODE : UE1+

Remark

LSU181HSV3
LSU240HSV3
LSU307HV3
LSU360HV3

Part Name
Air discharge grille
/I[XQXMKWVVMK\QWV
4QY]QLXQXMKWVVMK\QWV
8W_MZ<ZIV[UQ[[QWVKWVVMK\QWV
-IZ\P[KZM_
;>+^IT^MKW^MZ

LSU181HSV2
LSU240HSV2
LSU307HV2
LSU360HV2
LAU180HSV2
LAU240HSV2

Dimensional drawings
6RMI0-06A

Inverter Single
80(3 3/32)

392(15 13/32)

256(10 1/16)

234.3(9 1/4)

266.8(10 1/2)

717(28 1/4)

41

230(9 1/16)
1

56(2 3/16)

483(19 1/32)
57(2 1/4) 55(2 3/16)

462.8(18 1/4)

270(10 5/8)
10.7(7/16)

717(28 1/4)

Inverter Single
5

[Unit: mm (inch)]

CHASSIS CODE : UA3+

LSU090HEV
LSU120HEV

6RMI0-06A
Dimensional drawings

36

Wiring diagrams

6RMI0-06A

5. Wiring diagrams
5.1 Indoor units
Models: ASNW093B1Y9(LSN091HSV2), ASNW123B1Y9(LSN121HSV2)

Models: ASNW183C2Y9(LSN181HSV2)

37

Inverter Single

6RMI0-06A

Wiring diagrams

Models: ASNW093BRM9(LAN090HSV2), ASNW123BRM9(LAN120HSV2)

Models: ASNW183CRM9(LAN180HSV2), ASNW243CRM9(LAN240HSV2)

Inverter Single

38

Wiring diagrams

6RMI0-06A

Models: ASNW243DGY9(LSN240HSV2), ASNW303DGY9(LSN307HV2), ASNW363DGY9(LSN360HV2)

Models: ASNW093MMM9 (LSN090HYV), ASNW123MMM9 (LSN120HYV)

39

Inverter Single

6RMI0-06A

Wiring diagrams

Models: ASNW093F2B2(LAN090HVP), ASNW123F2B2(LAN120HVP)

Models: ASNW093WSA7 (LSN090HEV), ASNW123BSA7 (LSN120HEV),


ASNW183CSA7 (LSN180HEV), ASNW243CSA7 (LSN240HEV)

Inverter Single

40

Wiring diagrams

6RMI0-06A

Models: ASNW093MMB8 (LAN090HYV), ASNW123MMB8 (LAN120HYV)

Models: ASNW183C2B8 (LSN181HSV3)

41

Inverter Single

6RMI0-06A

Wiring diagrams

Models: ASNW243D8B8 (LSN240HSV3), ASNW303D8B8(LSN307HV3), ASNW363D8B8 (LSN360HV3)

Models: ASNW093B1B8 (LSN091HSV3), ASNW123B1B8(LSN121HSV3)

Inverter Single

42

Wiring diagrams

6RMI0-06A

5.2 Outdoor units


Models: ASUW093B1Y9(LSU091HSV2), ASUW123B1Y9(LSU121HSV2)
ASUW093BRM9(LAU090HSV2), ASUW123BRM9(LAU120HSV2)

Models: ASUW093MMM9 (LSU090HYV), ASUW123MMM9 (LSU120HYV)

43

Inverter Single

6RMI0-06A

Wiring diagrams

Models: ASUW183C2Y9(LSU181HSV2), ASUW183CRM9(LAU180HSV2), ASUW243CRM9(LAU240HSV2)

Models: ASUW243DGY9(LSU240HSV2), ASUW303DGY9(LSU307HV2), ASUW363DGY9(LSU360HV2)

Inverter Single

44

Wiring diagrams

6RMI0-06A

Models: ASUW093FUB2(LAU090HVP), ASUW123FUB2(LAU120HVP)

Models : ASUW093WSA7 (LSU090HEV), ASUW123BSA7 (LSU120HEV)

45

Inverter Single

6RMI0-06A

Wiring diagrams

Models : ASUW183CSA7 (LSU180HEV)

Models : ASUW243CSA7 (LSU240HEV)

Inverter Single

46

Wiring diagrams

6RMI0-06A

Models : ASUW093B1B8 (LSU091HSV3), ASUW123B1B8(LSU121HSV3)

Models : ASUW243D8B8 (LSU240HSV3), ASUW303D8B8(LSU307HV3),


ASUW363D8B8 (LSU360HV3), ASUW183C2B8 (LSU181HSV3)

47

Inverter Single

6RMI0-06A

Wiring diagrams

Models : ASUW093MMB8 (LAU090HYV), ASUW123MMB8 (LAU120HYV)

Inverter Single

48

Refrigerant cycle diagram

6RMI0-06A

6. Refrigerant cycle diagram


Models: AS-W093MMM9(LSN090HYV/LSU090HYV), AS-W123MMM9(LSN120HYV/LSU120HYV)
AS-W093MMB8 (LAN090HYV/ LAU090HYV), AS-W123MMB8 (LAN120HYV/ LAU120HYV)
Indoor Unit

Outdoor Unit

Liquid Side
EEV

2-Way Valve
Th1
Th4

Heat
Exchanger
(Evaporator)

Heat
Exchanger
(Condenser)

Th3

Th7

Th6

Gas Side
3-Way Valve

Reversing Valve

Accumulator

Th5

Cooling
Heating

Compressor

LOC.

Description

PCB Connector

Th1

Thermistor for sunction air temperature

CN-TH1(Indoor)

Th3

Water level sensor (Option)

CN-TH2(Indoor)

Th4

Thermistor for evaporator middle temperature

CN-TH3(Indoor)

Th5

Thermistor for discharge pipe temperature

CN-TH2(OUTDOOR)

Th6

Thermistor for condensing temperature

CN-TH1(OUTDOOR)

Th7

Thermistor for outdoor air temperature

CN-TH1(OUTDOOR)

EEV : Electronic Expansion Valve

49

Inverter Single

6RMI0-06A

Refrigerant cycle diagram

Models : AS-W093BRM9(LAN090HSV2/LAU090HSV2), AS-W123BRM9(LAN120HSV2/LAU120HSV2)


AS-W093B1Y9(LSN091HSV2/LSU091HSV2), AS-W123B1Y9(LSN121HSV2/LSU121HSV2)
AS-W093B1B8(LSN091HSV3/LSU091HSV3), AS-W123B1B8(LSN121HSV3/LSU121HSV3)
Indoor Unit

Outdoor Unit

Liquid Side
EEV

2-Way Valve
Th1
Th3

Heat
Exchanger
(Evaporator)

Heat
Exchanger
(Condenser)

Th2

Th6

Th5

Gas Side
3-Way Valve

Reversing Valve

Accumulator

Th4

Cooling
Heating

Compressor

LOC.

Description

PCB Connector

Th1

Thermistor for sunction air temperature

CN-TH1(Indoor)

Th2

Water Level Sensor (Option)

CN-TH2(Indoor)

Th3

Thermistor for evaporator middle temperature

CN-TH3(Indoor)

Th4

Thermistor for discharge pipe temperature

Th5

Thermistor for condensing temperature

Th6

Thermistor for outdoor air temperature

CN-TH2(Outdoor)
CN-TH1(Outdoor)

EEV : Electronic Expansion Valve

Inverter Single

50

Refrigerant cycle diagram

6RMI0-06A

Models : AS-W183CRM9(LAN180HSV2/LAU180HSV2), AS-W243CRM9(LAN240HSV2/LAU240HSV2),


AS-W183C2Y9(LSN181HSV2/LSU181HSV2), AS-W183C2B8 (LSN181HSV3/ LSU181HSV3)
Indoor Unit

Outdoor Unit

Liquid Side
EEV

2-Way Valve
Th1
Th3

Heat
Exchanger
(Evaporator)

Heat
Exchanger
(Condenser)

Th2

Th6

Th5

Gas Side
3-Way Valve

Reversing Valve

Accumulator

Th4

Cooling
Heating

Compressor

LOC.

Description

Th1

Thermistor for suction air temperature

Th2

Thermistor for evaporator inlet temperature

Th3

Thermistor for evaporator outlet temperature + Water level sensor

CN-TH2(Indoor)

Th4

Thermistor for evaporator middle temperature

CN-TH3(Indoor)

Th5

Thermistor for discharge pipe temperature

Th6

Thermistor for suction pipe temperature

Th7

Thermistor for condensing temperature

Th8

Thermistor for outdoor air temperature

Th9

Thermistor for condensing middle temperature

h EEV : Electronic Expansion Valve

51

PCB Connector

Inverter Single

CN-TH1(Indoor)

CN-TH3(Outdoor)

CN-TH2(Outdoor)
CN-TH4(Outdoor)

6RMI0-06A

Refrigerant cycle diagram

Models : AS-W243DGY9(LSN240HSV2/LSU240HSV2), AS-W303DGY9(LSN307HV2/LSU307HV2)


AS-W363DGY9(LSN360HV2/LSU360HV2), AS-W243D8B8(LSN240HSV3/LSU240HSV3)
AS-W303D8B8(LSN307HV3/LSU307HV3), AS-W363D8B8(LSN360HV3/LSU360HV3)
Indoor Unit

Outdoor Unit

Liquid Side
EEV

2-Way Valve

Th2
Th1
Th4

Heat
Exchanger
(Evaporator)

Heat
Exchanger
(Condenser)

Th8

Th9
Th3

Th7

Gas Side
Reversing Valve

Accumulator

3-Way Valve

Th5

Th6

Compressor

LOC.

Description

Cooling
Heating

PCB Connector

Th1

Thermistor for suction air temperature

Th2

Thermistor for evaporator inlet temperature

Th3

Thermistor for evaporator outlet temperature + Water level sensor

CN-TH2(Indoor)

Th4

Thermistor for evaporator middle temperature

CN-TH3(Indoor)

Th5

Thermistor for discharge pipe temperature

Th6

Thermistor for suction pipe temperature

Th7

Thermistor for condensing temperature

Th8

Thermistor for outdoor air temperature

Th9

Thermistor for condensing middle temperature

CN-TH1(Indoor)

CN-TH3(OUTDOOR)
CN-TH2(OUTDOOR)
CN-TH4(OUTDOOR)

h EEV : Electronic Expansion Valve

Inverter Single

52

Refrigerant cycle diagram

6RMI0-06A

Models : AS-W093F2B2(LAN090HVP/LAU090HVP), AS-W123F2B2(LAN120HVP/LAU120HVP)


Indoor Unit

Outdoor Unit

Liquid Side
EEV

2-Way Valve

Th2
Th1

Heat
Exchanger
(Evaporator)

Heat
Exchanger
(Condenser)
Th6
Th3
Th5

Gas Side
3-Way Valve

Reversing Valve

Accumulator

Th4

Cooling
Heating

Compressor

LOC

Description

Th1

Thermistor for indoor air temperature

CN_TH1(Indoor)

Th2

Water level sensor (Option)

CN_TH2(Indoor)

Th3

Thermistor for evaporating temperature

CN_TH3(Indoor)

Th4

Thermistor for discharge pipe temperature

CN_TH2(Outdoor)

Th5

Thermistor for condensing temperature

Th6

Thermistor for outdoor air temperature

h EEV : Electronic Expansion Valve.

53

PCB Connector

Inverter Single

CN_TH1(Outdoor)

6RMI0-06A

Refrigerant cycle diagram

Models: AS-W093WSA7 (LSN090HEV/LSU090HEV), AS-W123BSA7 (LSN120HEV/LSU120HEV)

Indoor Unit

Outdoor Unit

Liquid Side

Th2

Th3

Capillary
Tube

2-Way Valve

Th1

Heat
Exchanger
(Evaporator)

Heat
Exchanger
(Condenser)

Th6

Th5

Gas Side

Th4

Reversing Valve

Accumulator

3-Way Valve

Cooling
Heating

Compressor

LOC

Description

PCB Connector

Th1

Thermistor for indoor air temperature

CH-TH1(Indoor)

Th2

Water level sensor (Option)

CH-TH2(Indoor)

Th3

Thermistor for evaporating temperature

CH-TH3(INDOOR)

Th4

Thermistor for discharge pipe temperature

CN-TH2(OUTDOOR)

Th5

Thermistor for condensing temperature

CN-TH1(OUTDOOR)

Th6

Thermistor for outdoor air temperature

CN-TH1(OUTDOOR)

Inverter Single

54

Refrigerant cycle diagram

6RMI0-06A

Model : AS-W183CSA7 (LSN180HEV/LSU180HEV)


Indoor Unit

Outdoor Unit

Liquid Side

Th2

Th3

Capillary
Tube

2-Way Valve

Th1

Heat
Exchanger
(Evaporator)

Heat
Exchanger
(Condenser)

Th6

Th5

Gas Side
3-Way Valve

Th4

Reversing Valve

Accumulator

Cooling
Heating

Compressor

LOC

55

Description

PCB Connector

Th1

Thermistor for indoor air temperature

CH-TH1(Indoor)

Th2

Water level sensor (Option)

CH-TH2(Indoor)

Th3

Thermistor for evaporating temperature

CH-TH3(Indoor)

Th4

Thermistor for discharge pipe temperature

CN-TH2(Outdoor)

Th5

Thermistor for condensing temperature

CN-TH1(Outdoor)

Th6

Thermistor for outdoor air temperature

CN-TH1(Outdoor)

Inverter Single

6RMI0-06A

Refrigerant cycle diagram

Model : AS-W243CSA7 (LSN240HEV/LSU240HEV)


Indoor Unit

Outdoor Unit

Liquid Side

Th2

Th3

Capillary
Tube

2-Way Valve

Th1

Heat
Exchanger
(Evaporator)

Heat
Exchanger
(Condenser)

Th6

Th5

Gas Side

Th4

Reversing Valve

Accumulator

3-Way Valve

Cooling
Heating

Compressor

LOC

Description

PCB Connector

Th1

Thermistor for indoor air temperature

CH-TH1(Indoor)

Th2

Water level sensor (Option)

CH-TH2(Indoor)

Th3

Thermistor for evaporating temperature

CH-TH3(Indoor)

Th4

Thermistor for discharge pipe temperature

CN-TH2(Outdoor)

Th5

Thermistor for condensing temperature

CN-TH1(Outdoor)

Th6

Thermistor for outdoor air temperature

CN-TH1(Outdoor)

Inverter Single

56

Capacity tables

6RMI0-06A

7. Capacity tables
7.1 Cooling Capacity
AS-W093MMM9(LSN090HYV/LSU090HYV)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
8.10 8.48
8.00 8.54
7.79 8.61
7.58 8.72
7.37 8.85
7.15 8.89
6.96 8.87
6.77 8.85
6.59 8.82
6.40 8.81
6.21 8.82
5.92 8.84

PI
0.39
0.41
0.42
0.45
0.47
0.49
0.50
0.50
0.51
0.51
0.52
0.52

68 / 57
TC SHC PI
8.64 8.35 0.41
8.54 8.42 0.42
8.33 8.48 0.44
8.12 8.59 0.47
7.91 8.72 0.49
7.68 8.76 0.50
7.50 8.74 0.51
7.31 8.72 0.52
7.12 8.69 0.52
6.94 8.68 0.53
6.75 8.69 0.53
6.42 8.71 0.54

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
9.18 8.23 0.42 9.54 8.11 0.43 9.81 7.99
9.08 8.29 0.43 9.45 8.17 0.44 9.72 8.05
8.87 8.36 0.45 9.27 8.23 0.46 9.63 8.11
8.66 8.46 0.48 9.09 8.34 0.50 9.45 8.21
8.45 8.59 0.50 8.91 8.46 0.52 9.27 8.34
8.22 8.63 0.52 8.75 8.51 0.53 9.00 8.38
8.03 8.61 0.53 8.57 8.48 0.54 8.88 8.36
7.84 8.59 0.53 8.38 8.46 0.55 8.77 8.34
7.66 8.56 0.54 8.19 8.44 0.56 8.58 8.31
7.47 8.55 0.55 8.01 8.42 0.56 8.39 8.30
7.20 8.56 0.55 7.74 8.43 0.57 8.10 8.31
6.93 8.58 0.55 7.44 8.46 0.57 7.80 8.33

86 / 72
SHC PI
7.83 0.46
7.89 0.48
7.95 0.50
8.05 0.53
8.17 0.55
8.21 0.57
8.19 0.58
8.17 0.59
8.15 0.60
8.13 0.60
8.14 0.61
8.17 0.61

PI
0.45
0.46
0.48
0.51
0.53
0.55
0.56
0.57
0.57
0.58
0.59
0.59

TC
10.53
10.40
10.26
10.13
9.99
9.83
9.64
9.45
9.26
9.08
8.78
8.45

PI
0.69
0.71
0.74
0.79
0.82
0.85
0.86
0.88
0.89
0.90
0.91
0.91

86 / 72
TC SHC PI
14.04 10.43 0.72
13.86 10.51 0.74
13.68 10.59 0.77
13.50 10.72 0.82
13.32 10.88 0.86
13.10 10.94 0.88
12.85 10.91 0.90
12.60 10.88 0.91
12.35 10.85 0.92
12.10 10.83 0.93
11.70 10.84 0.94
11.27 10.87 0.95

TC
11.25
11.16
10.98
10.82
10.60
10.36
10.17
9.99
9.80
9.61
9.27
8.96

90 / 75
SHC PI
7.71 0.48
7.77 0.49
7.83 0.51
7.93 0.55
8.05 0.57
8.09 0.59
8.07 0.60
8.05 0.61
8.02 0.62
8.01 0.62
8.02 0.63
8.04 0.63

AS-W123MMM9(LSN120HYV/LSU120HYV)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
10.80 11.29
10.66 11.38
10.38 11.47
10.11 11.61
9.83 11.79
9.53 11.84
9.28 11.81
9.03 11.78
8.78 11.75
8.53 11.73
8.28 11.74
7.89 11.78

PI
0.61
0.63
0.65
0.70
0.73
0.75
0.77
0.78
0.79
0.79
0.80
0.81

68 / 57
TC SHC PI
11.52 11.12 0.63
11.38 11.21 0.65
11.10 11.30 0.67
10.83 11.44 0.72
10.55 11.61 0.75
10.25 11.67 0.78
10.00 11.64 0.79
9.75 11.61 0.80
9.50 11.58 0.81
9.25 11.55 0.82
9.00 11.57 0.83
8.56 11.60 0.83

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
12.24 10.96 0.65 12.72 10.80 0.67 13.08 10.64
12.11 11.04 0.67 12.60 10.88 0.69 12.96 10.72
11.82 11.13 0.70 12.36 10.97 0.72 12.84 10.80
11.54 11.27 0.74 12.12 11.10 0.77 12.60 10.94
11.26 11.44 0.78 11.88 11.27 0.80 12.36 11.10
10.96 11.50 0.80 11.67 11.33 0.82 12.00 11.16
10.71 11.47 0.81 11.42 11.30 0.84 11.84 11.13
10.46 11.44 0.83 11.17 11.27 0.85 11.69 11.10
10.21 11.41 0.84 10.92 11.24 0.86 11.44 11.07
9.96 11.38 0.84 10.67 11.21 0.87 11.19 11.05
9.60 11.40 0.85 10.32 11.23 0.88 10.80 11.06
9.24 11.43 0.86 9.91 11.26 0.88 10.40 11.10

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
SHC : Sensible Heating Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

57

90 / 75
TC SHC PI
15.00 10.27 0.74
14.88 10.35 0.76
14.64 10.43 0.79
14.42 10.56 0.85
14.13 10.72 0.88
13.81 10.77 0.91
13.56 10.75 0.93
13.31 10.72 0.94
13.07 10.69 0.95
12.82 10.67 0.96
12.36 10.68 0.97
11.94 10.71 0.97

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2.
Indicates reference data. When operating at this temperature,
these values can be different by discontinuous operation.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:80F(26.7C) DB / 67F(19.4C) WB
- Outdoor Air Temperature
:95F(35.0C) DB / 75F(23.9C) WB

Inverter Single

6RMI0-06A

Capacity tables

AS-W093B1Y9(LSN091HSV2/LSU091HSV2), AS-W093BRM9(LAN090HSV2/LAU090HSV2)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
8.10 9.10
8.00 9.17
7.79 9.24
7.58 9.35
7.37 9.49
7.15 9.54
6.96 9.52
6.77 9.49
6.59 9.47
6.40 9.45
6.21 9.46
5.92 9.49

PI
0.49
0.50
0.52
0.56
0.58
0.60
0.61
0.62
0.63
0.63
0.64
0.64

68 / 57
TC SHC PI
8.64 8.96 0.50
8.54 9.03 0.52
8.33 9.10 0.54
8.12 9.21 0.57
7.91 9.35 0.60
7.68 9.40 0.62
7.50 9.38 0.63
7.31 9.35 0.64
7.12 9.33 0.65
6.94 9.31 0.65
6.75 9.32 0.66
6.42 9.35 0.66

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
9.18 8.83 0.52 9.54 8.70 0.53 9.81 8.57
9.08 8.90 0.53 9.45 8.77 0.55 9.72 8.64
8.87 8.97 0.55 9.27 8.83 0.57 9.63 8.70
8.66 9.08 0.59 9.09 8.94 0.61 9.45 8.81
8.45 9.22 0.62 8.91 9.08 0.64 9.27 8.95
8.22 9.26 0.64 8.75 9.12 0.66 9.00 8.99
8.03 9.24 0.65 8.57 9.10 0.67 8.88 8.97
7.84 9.21 0.66 8.38 9.08 0.68 8.77 8.94
7.66 9.19 0.67 8.19 9.05 0.69 8.58 8.92
7.47 9.17 0.67 8.01 9.03 0.69 8.39 8.90
7.20 9.18 0.68 7.74 9.05 0.70 8.10 8.91
6.93 9.21 0.68 7.44 9.07 0.70 7.80 8.94

PI
0.55
0.56
0.59
0.63
0.66
0.68
0.69
0.70
0.71
0.71
0.72
0.72

TC
10.53
10.40
10.26
10.13
9.99
9.83
9.64
9.45
9.26
9.08
8.78
8.45

86 / 72
SHC PI
8.40 0.57
8.46 0.59
8.53 0.61
8.63 0.65
8.77 0.68
8.81 0.70
8.79 0.72
8.76 0.73
8.74 0.74
8.72 0.74
8.73 0.75
8.76 0.75

TC
11.25
11.16
10.98
10.82
10.60
10.36
10.17
9.99
9.80
9.61
9.27
8.96

90 / 75
SHC PI
8.27 0.59
8.34 0.60
8.40 0.63
8.50 0.67
8.63 0.70
8.68 0.73
8.66 0.74
8.63 0.75
8.61 0.76
8.59 0.77
8.60 0.77
8.63 0.78

AS-W123B1Y9(LSN121HSV2/LSU121HSV2), AS-W123BRM9(LAN120HSV2/LAU120HSV2)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
10.08 10.56
9.95 10.64
9.69 10.73
9.43 10.86
9.17 11.03
8.90 11.08
8.66 11.05
8.43 11.02
8.20 10.99
7.96 10.97
7.73 10.98
7.36 11.02

PI
0.64
0.66
0.69
0.74
0.77
0.79
0.81
0.82
0.83
0.84
0.84
0.85

68 / 57
TC SHC PI
10.75 10.41 0.66
10.63 10.49 0.68
10.36 10.57 0.71
10.10 10.70 0.76
9.84 10.86 0.79
9.56 10.92 0.82
9.33 10.89 0.83
9.10 10.86 0.85
8.86 10.83 0.85
8.63 10.81 0.86
8.40 10.82 0.87
7.99 10.86 0.87

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
11.42 10.25 0.68 11.87 10.10 0.70 12.21 9.95
11.30 10.33 0.70 11.76 10.18 0.72 12.10 10.03
11.04 10.41 0.73 11.54 10.26 0.76 11.98 10.11
10.77 10.54 0.78 11.31 10.38 0.81 11.76 10.23
10.51 10.70 0.82 11.09 10.54 0.84 11.54 10.39
10.23 10.76 0.84 10.89 10.60 0.87 11.20 10.44
10.00 10.73 0.86 10.66 10.57 0.88 11.05 10.41
9.76 10.70 0.87 10.43 10.54 0.90 10.91 10.39
9.53 10.67 0.88 10.20 10.51 0.91 10.68 10.36
9.30 10.65 0.89 9.96 10.49 0.92 10.44 10.34
8.96 10.66 0.90 9.63 10.51 0.93 10.08 10.35
8.62 10.69 0.90 9.25 10.54 0.93 9.71 10.38

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
SHC : Sensible Heating Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

PI
0.73
0.75
0.78
0.83
0.87
0.90
0.91
0.93
0.94
0.95
0.95
0.96

TC
13.10
12.94
12.77
12.60
12.43
12.23
11.99
11.76
11.53
11.30
10.92
10.51

86 / 72
SHC PI
9.75 0.76
9.83 0.78
9.90 0.81
10.03 0.87
10.18 0.90
10.23 0.93
10.20 0.95
10.18 0.96
10.15 0.97
10.13 0.98
10.14 0.99
10.17 1.00

TC
14.00
13.89
13.66
13.46
13.19
12.89
12.66
12.43
12.19
11.96
11.54
11.14

90 / 75
SHC PI
9.61 0.78
9.68 0.80
9.76 0.84
9.88 0.89
10.03 0.93
10.08 0.96
10.05 0.98
10.03 0.99
10.00 1.00
9.98 1.01
9.99 1.02
10.02 1.03

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2.
Indicates reference data. When operating at this temperature,
these values can be different by discontinuous operation.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:80F(26.7C) DB / 67F(19.4C) WB
- Outdoor Air Temperature
:95F(35.0C) DB / 75F(23.9C) WB

Inverter Single

58

Capacity tables

6RMI0-06A

AS-W183C2Y9(LSN181HSV2/LSU181HSV2), AS-W183BRM9(LAN180HSV2/LAU180HSV2)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
16.38 14.90
16.17 15.02
15.75 15.13
15.33 15.32
14.91 15.56
14.46 15.63
14.08 15.59
13.70 15.55
13.32 15.51
12.94 15.48
12.56 15.50
11.96 15.55

PI
1.04
1.07
1.12
1.19
1.25
1.28
1.31
1.33
1.34
1.35
1.37
1.37

68 / 57
TC SHC PI
17.47 14.68 1.07
17.27 14.80 1.10
16.84 14.91 1.15
16.42 15.09 1.23
16.00 15.33 1.28
15.54 15.40 1.32
15.16 15.36 1.35
14.78 15.32 1.37
14.40 15.28 1.38
14.02 15.25 1.40
13.65 15.27 1.41
12.99 15.32 1.42

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
18.56 14.47 1.11 19.29 14.25 1.14 19.84 14.04
18.36 14.58 1.14 19.11 14.36 1.17 19.66 14.15
17.93 14.69 1.19 18.75 14.47 1.22 19.47 14.26
17.51 14.87 1.27 18.38 14.65 1.31 19.11 14.44
17.08 15.10 1.32 18.02 14.88 1.36 18.75 14.66
16.62 15.18 1.36 17.70 14.95 1.41 18.20 14.73
16.24 15.14 1.39 17.32 14.91 1.43 17.96 14.69
15.86 15.10 1.41 16.95 14.87 1.45 17.73 14.65
15.49 15.05 1.43 16.57 14.83 1.47 17.35 14.61
15.11 15.02 1.44 16.19 14.80 1.48 16.97 14.58
14.56 15.04 1.45 15.65 14.82 1.50 16.38 14.60
14.01 15.09 1.46 15.04 14.87 1.50 15.78 14.65

PI
1.18
1.21
1.26
1.35
1.41
1.45
1.47
1.50
1.52
1.53
1.54
1.55

86 / 72
TC SHC PI
21.29 13.76 1.22
21.02 13.87 1.26
20.75 13.97 1.31
20.48 14.15 1.40
20.20 14.36 1.46
19.87 14.44 1.51
19.49 14.40 1.53
19.11 14.36 1.56
18.73 14.32 1.58
18.35 14.29 1.59
17.75 14.31 1.61
17.09 14.35 1.61

PI
1.65
1.70
1.77
1.90
1.98
2.04
2.07
2.11
2.13
2.15
2.17
2.18

TC
25.74
25.41
25.08
24.75
24.42
24.02
23.56
23.10
22.64
22.19
21.45
20.65

90 / 75
TC SHC PI
22.75 13.55 1.26
22.57 13.66 1.29
22.20 13.76 1.35
21.87 13.93 1.44
21.44 14.15 1.51
20.95 14.22 1.55
20.57 14.18 1.58
20.19 14.15 1.61
19.82 14.11 1.62
19.44 14.08 1.64
18.75 14.10 1.65
18.11 14.14 1.66

AS-W243CRM9(LAN240HSV2/LAU240HSV2)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
19.80 17.58
19.55 17.72
19.03 17.86
18.53 18.08
18.02 18.35
17.47 18.45
17.02 18.40
16.56 18.35
16.10 18.30
15.64 18.26
15.18 18.29
14.46 18.34

PI
1.46
1.51
1.57
1.68
1.75
1.81
1.84
1.87
1.89
1.91
1.92
1.93

68 / 57
TC SHC PI
21.12 17.32 1.51
20.87 17.46 1.55
20.36 17.59 1.62
19.85 17.81 1.73
19.34 18.08 1.81
18.78 18.17 1.86
18.33 18.13 1.89
17.87 18.08 1.92
17.41 18.03 1.95
16.95 17.99 1.96
16.50 18.02 1.98
15.70 18.07 1.99

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
22.44 17.07 1.56 23.32 16.82 1.60 23.98 16.57
22.20 17.20 1.60 23.10 16.95 1.65 23.76 16.70
21.68 17.33 1.67 22.66 17.08 1.72 23.54 16.83
21.16 17.55 1.79 22.22 17.29 1.84 23.10 17.03
20.65 17.82 1.86 21.78 17.55 1.92 22.66 17.29
20.09 17.91 1.92 21.40 17.64 1.98 22.00 17.38
19.63 17.86 1.95 20.94 17.60 2.01 21.71 17.34
19.18 17.81 1.98 20.48 17.55 2.05 21.43 17.29
18.72 17.76 2.01 20.03 17.50 2.07 20.97 17.24
18.26 17.73 2.03 19.57 17.46 2.09 20.52 17.21
17.60 17.75 2.04 18.92 17.49 2.11 19.80 17.23
16.94 17.80 2.05 18.18 17.54 2.12 19.07 17.28

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
SHC : Sensible Heating Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

59

86 / 72
SHC PI
16.24 1.72
16.36 1.77
16.49 1.85
16.69 1.97
16.95 2.06
17.03 2.12
16.99 2.16
16.94 2.19
16.90 2.22
16.86 2.24
16.89 2.26
16.94 2.27

TC
27.50
27.28
26.84
26.44
25.91
25.33
24.87
24.41
23.95
23.50
22.66
21.89

90 / 75
SHC PI
15.99 1.77
16.12 1.82
16.24 1.90
16.44 2.03
16.69 2.12
16.78 2.19
16.73 2.22
16.69 2.26
16.64 2.28
16.61 2.31
16.63 2.33
16.68 2.34

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2.
Indicates reference data. When operating at this temperature,
these values can be different by discontinuous operation.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:80F(26.7C) DB / 67F(19.4C) WB
- Outdoor Air Temperature
:95F(35.0C) DB / 75F(23.9C) WB

Inverter Single

6RMI0-06A

Capacity tables

AS-W243DGY9(LSN240HSV2/LSU240HSV2)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
19.80 18.47
19.55 18.62
19.03 18.76
18.53 18.99
18.02 19.28
17.47 19.38
17.02 19.33
16.56 19.28
16.10 19.23
15.64 19.19
15.18 19.21
14.46 19.27

PI
1.26
1.30
1.36
1.45
1.51
1.56
1.58
1.61
1.63
1.64
1.66
1.67

68 / 57
TC SHC PI
21.12 18.20 1.30
20.87 18.34 1.34
20.36 18.48 1.40
19.85 18.71 1.49
19.34 19.00 1.56
18.78 19.09 1.61
18.33 19.05 1.63
17.87 19.00 1.66
17.41 18.94 1.68
16.95 18.90 1.69
16.50 18.93 1.71
15.70 18.99 1.72

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
22.44 17.93 1.34 23.32 17.67 1.38 23.98 17.41
22.20 18.07 1.38 23.10 17.80 1.42 23.76 17.54
21.68 18.21 1.44 22.66 17.94 1.49 23.54 17.68
21.16 18.44 1.54 22.22 18.16 1.59 23.10 17.89
20.65 18.72 1.61 21.78 18.44 1.66 22.66 18.17
20.09 18.81 1.66 21.40 18.53 1.71 22.00 18.26
19.63 18.76 1.68 20.94 18.49 1.74 21.71 18.21
19.18 18.72 1.71 20.48 18.44 1.76 21.43 18.17
18.72 18.66 1.73 20.03 18.39 1.78 20.97 18.11
18.26 18.62 1.75 19.57 18.35 1.80 20.52 18.08
17.60 18.65 1.76 18.92 18.37 1.82 19.80 18.10
16.94 18.71 1.77 18.18 18.43 1.83 19.07 18.16

PI
1.43
1.47
1.53
1.64
1.71
1.76
1.79
1.82
1.84
1.86
1.87
1.88

86 / 72
TC SHC PI
25.74 17.06 1.48
25.41 17.19 1.53
25.08 17.32 1.59
24.75 17.54 1.70
24.42 17.81 1.78
24.02 17.89 1.83
23.56 17.85 1.86
23.10 17.80 1.89
22.64 17.75 1.91
22.19 17.72 1.93
21.45 17.74 1.95
20.65 17.79 1.96

PI
2.43
2.50
2.61
2.79
2.91
3.00
3.05
3.10
3.14
3.17
3.20
3.21

TC
35.10
34.65
34.20
33.75
33.30
32.75
32.13
31.50
30.88
30.26
29.25
28.16

90 / 75
TC SHC PI
27.50 16.80 1.53
27.28 16.93 1.57
26.84 17.06 1.64
26.44 17.27 1.75
25.91 17.54 1.83
25.33 17.63 1.89
24.87 17.58 1.92
24.41 17.54 1.95
23.95 17.49 1.97
23.50 17.45 1.99
22.66 17.47 2.01
21.89 17.53 2.02

AS-W303DGY9(LSN307HV2/LSU307HV2)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
27.00 20.28
26.65 20.44
25.96 20.60
25.27 20.85
24.57 21.17
23.83 21.28
23.20 21.23
22.58 21.17
21.96 21.11
21.33 21.07
20.70 21.10
19.72 21.16

PI
2.15
2.21
2.31
2.47
2.58
2.66
2.70
2.74
2.78
2.80
2.83
2.84

68 / 57
TC SHC PI
28.80 19.98 2.22
28.46 20.14 2.28
27.76 20.30 2.38
27.06 20.55 2.55
26.37 20.86 2.66
25.61 20.97 2.74
24.99 20.91 2.78
24.37 20.86 2.83
23.74 20.80 2.86
23.12 20.76 2.89
22.50 20.78 2.92
21.41 20.85 2.93

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
30.60 19.69 2.29 31.80 19.40 2.36 32.70 19.11
30.27 19.84 2.35 31.50 19.55 2.43 32.40 19.26
29.56 20.00 2.46 30.90 19.70 2.53 32.10 19.41
28.86 20.24 2.63 30.30 19.94 2.71 31.50 19.65
28.16 20.55 2.74 29.70 20.25 2.82 30.90 19.95
27.40 20.66 2.82 29.18 20.35 2.91 30.00 20.05
26.77 20.60 2.87 28.56 20.30 2.96 29.61 20.00
26.15 20.55 2.92 27.93 20.25 3.01 29.22 19.95
25.53 20.49 2.95 27.31 20.19 3.04 28.60 19.89
24.90 20.45 2.98 26.69 20.15 3.07 27.98 19.85
24.00 20.48 3.01 25.80 20.17 3.10 27.00 19.88
23.10 20.54 3.02 24.78 20.24 3.11 26.00 19.94

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
SHC : Sensible Heating Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

86 / 72
SHC PI
18.73 2.53
18.88 2.60
19.02 2.71
19.26 2.90
19.55 3.03
19.65 3.12
19.60 3.17
19.55 3.22
19.49 3.26
19.45 3.29
19.48 3.32
19.54 3.34

TC
37.50
37.20
36.60
36.05
35.33
34.53
33.91
33.29
32.66
32.04
30.90
29.85

90 / 75
SHC PI
18.45 2.60
18.59 2.68
18.74 2.80
18.97 2.99
19.26 3.12
19.35 3.21
19.30 3.27
19.25 3.32
19.20 3.36
19.16 3.39
19.19 3.42
19.24 3.44

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2.
Indicates reference data. When operating at this temperature,
these values can be different by discontinuous operation.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:80F(26.7C) DB / 67F(19.4C) WB
- Outdoor Air Temperature
:95F(35.0C) DB / 75F(23.9C) WB

Inverter Single

60

Capacity tables

6RMI0-06A

AS-W363DGY9(LSN360HV2/LSU360HV2)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
29.70 20.84
29.32 21.00
28.55 21.17
27.79 21.43
27.03 21.75
26.21 21.86
25.53 21.81
24.84 21.75
24.15 21.69
23.47 21.65
22.77 21.68
21.69 21.74

PI
2.90
2.98
3.11
3.33
3.47
3.58
3.64
3.70
3.74
3.77
3.81
3.83

68 / 57
TC SHC PI
31.68 20.53 2.99
31.31 20.69 3.07
30.53 20.85 3.21
29.77 21.11 3.43
29.00 21.43 3.58
28.17 21.54 3.69
27.49 21.49 3.75
26.80 21.43 3.81
26.12 21.37 3.85
25.43 21.33 3.89
24.75 21.35 3.93
23.55 21.42 3.95

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
33.66 20.23 3.08 34.98 19.93 3.18 35.97 19.64
33.29 20.39 3.17 34.65 20.09 3.27 35.64 19.79
32.52 20.55 3.31 33.99 20.24 3.41 35.31 19.94
31.75 20.80 3.54 33.33 20.49 3.64 34.65 20.19
30.98 21.12 3.69 32.67 20.80 3.80 33.99 20.50
30.14 21.22 3.80 32.10 20.91 3.92 33.00 20.60
29.45 21.17 3.86 31.41 20.86 3.98 32.57 20.55
28.76 21.11 3.93 30.73 20.80 4.05 32.14 20.49
28.08 21.05 3.97 30.04 20.74 4.10 31.46 20.44
27.39 21.01 4.01 29.36 20.70 4.13 30.77 20.39
26.40 21.04 4.05 28.38 20.73 4.17 29.70 20.42
25.40 21.10 4.07 27.26 20.79 4.19 28.60 20.48

PI
3.27
3.37
3.51
3.76
3.92
4.04
4.11
4.18
4.22
4.26
4.30
4.32

86 / 72
TC SHC PI
38.61 19.24 3.41
38.12 19.39 3.50
37.62 19.54 3.66
37.13 19.78 3.91
36.63 20.09 4.08
36.03 20.19 4.20
35.34 20.14 4.27
34.65 20.08 4.34
33.97 20.03 4.39
33.28 19.99 4.43
32.18 20.01 4.47
30.98 20.07 4.50

PI
0.58
0.60
0.63
0.67
0.70
0.72
0.73
0.74
0.75
0.76
0.77
0.77

TC
10.53
10.40
10.26
10.13
9.99
9.83
9.64
9.45
9.26
9.08
8.78
8.45

90 / 75
TC SHC PI
41.25 18.95 3.51
40.92 19.10 3.61
40.26 19.25 3.77
39.66 19.49 4.02
38.87 19.79 4.20
37.99 19.89 4.33
37.30 19.83 4.40
36.62 19.78 4.47
35.93 19.73 4.52
35.24 19.69 4.57
33.99 19.71 4.61
32.84 19.77 4.63

AS-W093F2B2(LAN090HVP/LAU090HVP)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
8.10 6.84
8.00 6.89
7.79 6.95
7.58 7.03
7.37 7.14
7.15 7.17
6.96 7.16
6.77 7.14
6.59 7.12
6.40 7.10
6.21 7.11
5.92 7.13

PI
0.52
0.53
0.55
0.59
0.62
0.64
0.65
0.66
0.67
0.67
0.68
0.68

68 / 57
TC SHC PI
8.64 6.74 0.53
8.54 6.79 0.55
8.33 6.84 0.57
8.12 6.93 0.61
7.91 7.03 0.64
7.68 7.07 0.66
7.50 7.05 0.67
7.31 7.03 0.68
7.12 7.01 0.69
6.94 7.00 0.69
6.75 7.01 0.70
6.42 7.03 0.70

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
9.18 6.64 0.55 9.54 6.54 0.57 9.81 6.44
9.08 6.69 0.56 9.45 6.59 0.58 9.72 6.49
8.87 6.74 0.59 9.27 6.64 0.61 9.63 6.54
8.66 6.83 0.63 9.09 6.72 0.65 9.45 6.62
8.45 6.93 0.66 8.91 6.83 0.68 9.27 6.73
8.22 6.96 0.68 8.75 6.86 0.70 9.00 6.76
8.03 6.95 0.69 8.57 6.84 0.71 8.88 6.74
7.84 6.93 0.70 8.38 6.83 0.72 8.77 6.73
7.66 6.91 0.71 8.19 6.81 0.73 8.58 6.71
7.47 6.89 0.71 8.01 6.79 0.74 8.39 6.69
7.20 6.90 0.72 7.74 6.80 0.74 8.10 6.70
6.93 6.92 0.72 7.44 6.82 0.75 7.80 6.72

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
SHC : Sensible Heating Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

61

86 / 72
SHC PI
6.31 0.61
6.36 0.62
6.41 0.65
6.49 0.70
6.59 0.73
6.62 0.75
6.61 0.76
6.59 0.77
6.57 0.78
6.56 0.79
6.57 0.80
6.59 0.80

TC
11.25
11.16
10.98
10.82
10.60
10.36
10.17
9.99
9.80
9.61
9.27
8.96

90 / 75
SHC PI
6.22 0.63
6.27 0.64
6.32 0.67
6.39 0.72
6.49 0.75
6.53 0.77
6.51 0.78
6.49 0.80
6.47 0.81
6.46 0.81
6.47 0.82
6.49 0.83

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2.
Indicates reference data. When operating at this temperature,
these values can be different by discontinuous operation.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:80F(26.7C) DB / 67F(19.4C) WB
- Outdoor Air Temperature
:95F(35.0C) DB / 75F(23.9C) WB

Inverter Single

6RMI0-06A

Capacity tables

AS-W123F2B2(LAN120HVP/LAU120HVP)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
10.08 8.49
9.95 8.55
9.69 8.62
9.43 8.73
9.17 8.86
8.90 8.90
8.66 8.88
8.43 8.86
8.20 8.83
7.96 8.82
7.73 8.83
7.36 8.85

PI
0.67
0.69
0.72
0.77
0.80
0.82
0.84
0.85
0.86
0.87
0.88
0.88

68 / 57
TC SHC PI
10.75 8.36 0.69
10.63 8.43 0.71
10.36 8.49 0.74
10.10 8.60 0.79
9.84 8.73 0.82
9.56 8.77 0.85
9.33 8.75 0.86
9.10 8.73 0.88
8.86 8.70 0.89
8.63 8.69 0.90
8.40 8.70 0.90
7.99 8.72 0.91

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
11.42 8.24 0.71 11.87 8.12 0.73 12.21 8.00
11.30 8.30 0.73 11.76 8.18 0.75 12.10 8.06
11.04 8.37 0.76 11.54 8.24 0.78 11.98 8.12
10.77 8.47 0.81 11.31 8.35 0.84 11.76 8.22
10.51 8.60 0.85 11.09 8.47 0.88 11.54 8.35
10.23 8.64 0.88 10.89 8.52 0.90 11.20 8.39
10.00 8.62 0.89 10.66 8.49 0.92 11.05 8.37
9.76 8.60 0.90 10.43 8.47 0.93 10.91 8.35
9.53 8.57 0.91 10.20 8.45 0.94 10.68 8.32
9.30 8.56 0.92 9.96 8.43 0.95 10.44 8.31
8.96 8.57 0.93 9.63 8.44 0.96 10.08 8.32
8.62 8.59 0.94 9.25 8.47 0.97 9.71 8.34

PI
0.75
0.78
0.81
0.86
0.90
0.93
0.95
0.96
0.97
0.98
0.99
1.00

86 / 72
TC SHC PI
13.10 7.84 0.78
12.94 7.90 0.81
12.77 7.96 0.84
12.60 8.06 0.90
12.43 8.18 0.94
12.23 8.22 0.97
11.99 8.20 0.98
11.76 8.18 1.00
11.53 8.16 1.01
11.30 8.14 1.02
10.92 8.15 1.03
10.51 8.18 1.03

PI
0.63
0.65
0.68
0.73
0.76
0.78
0.79
0.81
0.82
0.82
0.83
0.83

TC
9.95
9.82
9.69
9.56
9.44
9.28
9.10
8.93
8.75
8.57
8.29
7.98

90 / 75
TC SHC PI
14.00 7.72 0.81
13.89 7.78 0.83
13.66 7.84 0.87
13.46 7.94 0.93
13.19 8.06 0.97
12.89 8.10 1.00
12.66 8.08 1.01
12.43 8.06 1.03
12.19 8.03 1.04
11.96 8.02 1.05
11.54 8.03 1.06
11.14 8.05 1.07

AS-W093WSA7 (LSN090HEV/LSU090HEV)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
7.65 6.95
7.55 7.00
7.35 7.06
7.16 7.15
6.96 7.26
6.75 7.29
6.57 7.27
6.40 7.25
6.22 7.23
6.04 7.22
5.87 7.23
5.59 7.25

PI
0.56
0.58
0.60
0.64
0.67
0.69
0.70
0.71
0.72
0.73
0.74
0.74

68 / 57
TC SHC PI
8.16 6.85 0.58
8.06 6.90 0.59
7.86 6.95 0.62
7.67 7.04 0.66
7.47 7.15 0.69
7.26 7.18 0.71
7.08 7.17 0.72
6.90 7.15 0.74
6.73 7.13 0.74
6.55 7.11 0.75
6.38 7.12 0.76
6.07 7.14 0.76

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
8.67 6.75 0.59 9.01 6.65 0.61 9.27 6.55
8.58 6.80 0.61 8.93 6.70 0.63 9.18 6.60
8.38 6.85 0.64 8.76 6.75 0.66 9.10 6.65
8.18 6.94 0.68 8.59 6.83 0.70 8.93 6.73
7.98 7.04 0.71 8.42 6.94 0.73 8.76 6.84
7.76 7.08 0.73 8.27 6.97 0.76 8.50 6.87
7.59 7.06 0.75 8.09 6.96 0.77 8.39 6.85
7.41 7.04 0.76 7.91 6.94 0.78 8.28 6.83
7.23 7.02 0.77 7.74 6.92 0.79 8.10 6.82
7.06 7.01 0.77 7.56 6.90 0.80 7.93 6.80
6.80 7.02 0.78 7.31 6.91 0.81 7.65 6.81
6.54 7.04 0.79 7.02 6.93 0.81 7.37 6.83

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
SHC : Sensible Heating Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

86 / 72
SHC PI
6.42 0.66
6.47 0.68
6.52 0.71
6.60 0.75
6.70 0.79
6.73 0.81
6.72 0.82
6.70 0.84
6.68 0.85
6.67 0.86
6.67 0.86
6.69 0.87

TC
10.63
10.54
10.37
10.21
10.01
9.78
9.61
9.43
9.25
9.08
8.76
8.46

90 / 75
SHC PI
6.32 0.68
6.37 0.70
6.42 0.73
6.50 0.78
6.60 0.81
6.63 0.84
6.61 0.85
6.60 0.86
6.58 0.87
6.57 0.88
6.57 0.89
6.59 0.89

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2.
Indicates reference data. When operating at this temperature,
these values can be different by discontinuous operation.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:80F(26.7C) DB / 67F(19.4C) WB
- Outdoor Air Temperature
:95F(35.0C) DB / 75F(23.9C) WB

Inverter Single

62

Capacity tables

6RMI0-06A

AS-W123BSA7 (LSN120HEV/LSU120HEV)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
10.80 10.09
10.66 10.17
10.38 10.24
10.11 10.37
9.83 10.53
9.53 10.58
9.28 10.55
9.03 10.53
8.78 10.50
8.53 10.48
8.28 10.49
7.89 10.52

PI
0.84
0.86
0.90
0.96
1.00
1.04
1.05
1.07
1.08
1.09
1.10
1.11

68 / 57
TC SHC PI
11.52 9.94 0.87
11.38 10.02 0.89
11.10 10.09 0.93
10.83 10.22 0.99
10.55 10.37 1.04
10.25 10.43 1.07
10.00 10.40 1.09
9.75 10.37 1.10
9.50 10.34 1.12
9.25 10.32 1.13
9.00 10.34 1.14
8.56 10.37 1.14

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
12.24 9.79 0.89 12.72 9.65 0.92 13.08 9.50
12.11 9.87 0.92 12.60 9.72 0.95 12.96 9.58
11.82 9.94 0.96 12.36 9.80 0.99 12.84 9.65
11.54 10.07 1.02 12.12 9.92 1.06 12.60 9.77
11.26 10.22 1.07 11.88 10.07 1.10 12.36 9.92
10.96 10.27 1.10 11.67 10.12 1.13 12.00 9.97
10.71 10.24 1.12 11.42 10.09 1.15 11.84 9.94
10.46 10.22 1.14 11.17 10.07 1.17 11.69 9.92
10.21 10.19 1.15 10.92 10.04 1.19 11.44 9.89
9.96 10.17 1.16 10.67 10.02 1.20 11.19 9.87
9.60 10.18 1.17 10.32 10.03 1.21 10.80 9.88
9.24 10.21 1.18 9.91 10.06 1.21 10.40 9.91

PI
0.95
0.98
1.02
1.09
1.13
1.17
1.19
1.21
1.22
1.23
1.25
1.25

86 / 72
TC SHC PI
14.04 9.31 0.99
13.86 9.39 1.01
13.68 9.46 1.06
13.50 9.58 1.13
13.32 9.72 1.18
13.10 9.77 1.22
12.85 9.75 1.24
12.60 9.72 1.26
12.35 9.69 1.27
12.10 9.67 1.28
11.70 9.69 1.30
11.27 9.72 1.30

PI
1.26
1.29
1.35
1.44
1.50
1.55
1.58
1.60
1.62
1.64
1.65
1.66

TC
19.89
19.64
19.38
19.13
18.87
18.56
18.20
17.85
17.50
17.14
16.58
15.96

90 / 75
TC SHC PI
15.00 9.17 1.02
14.88 9.25 1.04
14.64 9.32 1.09
14.42 9.43 1.17
14.13 9.58 1.22
13.81 9.62 1.25
13.56 9.60 1.27
13.31 9.57 1.30
13.07 9.55 1.31
12.82 9.53 1.32
12.36 9.54 1.33
11.94 9.57 1.34

AS-W183CSA7 (LSN180HEV/LSU180HEV)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
15.30 13.23
15.10 13.34
14.71 13.44
14.32 13.60
13.93 13.81
13.50 13.88
13.15 13.85
12.80 13.81
12.44 13.77
12.09 13.74
11.73 13.76
11.17 13.80

PI
1.11
1.14
1.19
1.28
1.33
1.37
1.40
1.42
1.43
1.45
1.46
1.47

68 / 57
TC SHC PI
16.32 13.04 1.15
16.13 13.14 1.18
15.73 13.24 1.23
15.34 13.40 1.32
14.94 13.61 1.37
14.51 13.68 1.41
14.16 13.64 1.44
13.81 13.61 1.46
13.45 13.57 1.48
13.10 13.54 1.49
12.75 13.56 1.51
12.13 13.60 1.51

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
17.34 12.84 1.18 18.02 12.66 1.22 18.53 12.47
17.15 12.95 1.22 17.85 12.75 1.25 18.36 12.57
16.75 13.05 1.27 17.51 12.85 1.31 18.19 12.66
16.35 13.21 1.36 17.17 13.01 1.40 17.85 12.82
15.96 13.41 1.41 16.83 13.21 1.46 17.51 13.01
15.52 13.48 1.46 16.54 13.28 1.50 17.00 13.08
15.17 13.44 1.48 16.18 13.24 1.53 16.78 13.05
14.82 13.41 1.51 15.83 13.21 1.55 16.56 13.01
14.46 13.37 1.52 15.48 13.17 1.57 16.21 12.98
14.11 13.34 1.54 15.12 13.14 1.59 15.85 12.95
13.60 13.36 1.55 14.62 13.16 1.60 15.30 12.97
13.09 13.40 1.56 14.04 13.20 1.61 14.74 13.01

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
SHC : Sensible Heating Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

63

86 / 72
SHC PI
12.22 1.31
12.31 1.34
12.41 1.40
12.56 1.50
12.75 1.56
12.82 1.61
12.79 1.64
12.75 1.67
12.72 1.68
12.69 1.70
12.71 1.72
12.75 1.72

TC
21.25
21.08
20.74
20.43
20.02
19.57
19.22
18.86
18.51
18.16
17.51
16.92

90 / 75
SHC PI
12.04 1.35
12.13 1.38
12.22 1.44
12.37 1.54
12.56 1.61
12.63 1.66
12.59 1.69
12.56 1.72
12.53 1.74
12.50 1.75
12.52 1.77
12.55 1.78

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2.
Indicates reference data. When operating at this temperature,
these values can be different by discontinuous operation.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:80F(26.7C) DB / 67F(19.4C) WB
- Outdoor Air Temperature
:95F(35.0C) DB / 75F(23.9C) WB

Inverter Single

6RMI0-06A

Capacity tables

AS-W243CSA7 (LSN240HEV/LSU240HEV)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
19.80 21.03
19.55 21.20
19.03 21.36
18.53 21.62
18.02 21.96
17.47 22.07
17.02 22.01
16.56 21.95
16.10 21.89
15.64 21.85
15.18 21.88
14.46 21.94

PI
1.47
1.51
1.58
1.69
1.76
1.81
1.85
1.88
1.90
1.91
1.93
1.94

68 / 57
TC SHC PI
21.12 20.72 1.52
20.87 20.88 1.56
20.36 21.05 1.63
19.85 21.30 1.74
19.34 21.63 1.81
18.78 21.74 1.87
18.33 21.68 1.90
17.87 21.63 1.93
17.41 21.57 1.96
16.95 21.52 1.97
16.50 21.55 1.99
15.70 21.62 2.00

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
22.44 20.42 1.56 23.32 20.11 1.61 23.98 19.82
22.20 20.58 1.61 23.10 20.27 1.66 23.76 19.97
21.68 20.73 1.68 22.66 20.43 1.73 23.54 20.13
21.16 20.99 1.79 22.22 20.68 1.85 23.10 20.37
20.65 21.31 1.87 21.78 21.00 1.93 22.66 20.69
20.09 21.42 1.93 21.40 21.10 1.99 22.00 20.79
19.63 21.36 1.96 20.94 21.05 2.02 21.71 20.74
19.18 21.31 1.99 20.48 20.99 2.06 21.43 20.68
18.72 21.25 2.02 20.03 20.93 2.08 20.97 20.62
18.26 21.20 2.03 19.57 20.89 2.10 20.52 20.58
17.60 21.23 2.05 18.92 20.92 2.12 19.80 20.61
16.94 21.30 2.06 18.18 20.98 2.13 19.07 20.67

PI
1.66
1.71
1.78
1.91
1.99
2.05
2.08
2.12
2.14
2.16
2.18
2.19

86 / 72
TC SHC PI
25.74 19.42 1.73
25.41 19.57 1.78
25.08 19.72 1.85
24.75 19.97 1.98
24.42 20.27 2.07
24.02 20.37 2.13
23.56 20.32 2.17
23.10 20.27 2.20
22.64 20.21 2.23
22.19 20.17 2.25
21.45 20.20 2.27
20.65 20.26 2.28

PI
0.45
0.47
0.49
0.52
0.54
0.56
0.57
0.58
0.59
0.59
0.60
0.60

TC
10.53
10.40
10.26
10.13
9.99
9.83
9.64
9.45
9.26
9.08
8.78
8.45

90 / 75
TC SHC PI
27.50 19.13 1.78
27.28 19.28 1.83
26.84 19.43 1.91
26.44 19.67 2.04
25.91 19.97 2.13
25.33 20.07 2.20
24.87 20.02 2.23
24.41 19.97 2.27
23.95 19.91 2.29
23.50 19.87 2.32
22.66 19.90 2.34
21.89 19.96 2.35

AS-W093MMB8 (LAN090HYV/LAU090HYV)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
8.10 7.65
8.00 7.71
7.79 7.77
7.58 7.86
7.37 7.98
7.15 8.02
6.96 8.00
6.77 7.98
6.59 7.96
6.40 7.94
6.21 7.95
5.92 7.98

PI
0.40
0.41
0.43
0.46
0.48
0.50
0.50
0.51
0.52
0.52
0.53
0.53

68 / 57
TC SHC PI
8.64 7.54 0.41
8.54 7.59 0.43
8.33 7.65 0.44
8.12 7.75 0.48
7.91 7.87 0.50
7.68 7.91 0.51
7.50 7.89 0.52
7.31 7.86 0.53
7.12 7.84 0.53
6.94 7.83 0.54
6.75 7.84 0.54
6.42 7.86 0.55

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
9.18 7.42 0.43 9.54 7.31 0.44 9.81 7.21
9.08 7.48 0.44 9.45 7.37 0.45 9.72 7.26
8.87 7.54 0.46 9.27 7.43 0.47 9.63 7.32
8.66 7.63 0.49 9.09 7.52 0.51 9.45 7.41
8.45 7.75 0.51 8.91 7.64 0.53 9.27 7.52
8.22 7.79 0.53 8.75 7.67 0.54 9.00 7.56
8.03 7.77 0.54 8.57 7.65 0.55 8.88 7.54
7.84 7.75 0.54 8.38 7.63 0.56 8.77 7.52
7.66 7.73 0.55 8.19 7.61 0.57 8.58 7.50
7.47 7.71 0.56 8.01 7.60 0.57 8.39 7.48
7.20 7.72 0.56 7.74 7.61 0.58 8.10 7.49
6.93 7.74 0.56 7.44 7.63 0.58 7.80 7.52

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
SHC : Sensible Heating Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

86 / 72
SHC PI
7.06 0.47
7.12 0.49
7.17 0.51
7.26 0.54
7.37 0.56
7.41 0.58
7.39 0.59
7.37 0.60
7.35 0.61
7.33 0.61
7.34 0.62
7.37 0.62

TC
11.25
11.16
10.98
10.82
10.60
10.36
10.17
9.99
9.80
9.61
9.27
8.96

90 / 75
SHC PI
6.96 0.49
7.01 0.50
7.06 0.52
7.15 0.56
7.26 0.58
7.30 0.60
7.28 0.61
7.26 0.62
7.24 0.63
7.22 0.63
7.23 0.64
7.26 0.64

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2.
Indicates reference data. When operating at this temperature,
these values can be different by discontinuous operation.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:80F(26.7C) DB / 67F(19.4C) WB
- Outdoor Air Temperature
:95F(35.0C) DB / 75F(23.9C) WB

Inverter Single

64

Capacity tables

6RMI0-06A

AS-W123MMB8(LAN120HYV/LAU120HYV)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
10.80 9.83
10.66 9.91
10.38 9.99
10.11 10.11
9.83 10.26
9.53 10.32
9.28 10.29
9.03 10.26
8.78 10.23
8.53 10.21
8.28 10.23
7.89 10.26

PI
0.61
0.63
0.65
0.70
0.73
0.75
0.77
0.78
0.79
0.79
0.80
0.81

68 / 57
TC SHC PI
11.52 9.69 0.63
11.38 9.76 0.65
11.10 9.84 0.67
10.83 9.96 0.72
10.55 10.11 0.75
10.25 10.16 0.78
10.00 10.14 0.79
9.75 10.11 0.80
9.50 10.08 0.81
9.25 10.06 0.82
9.00 10.08 0.83
8.56 10.11 0.83

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
12.24 9.55 0.65 12.72 9.40 0.67 13.08 9.27
12.11 9.62 0.67 12.60 9.48 0.69 12.96 9.34
11.82 9.69 0.70 12.36 9.55 0.72 12.84 9.41
11.54 9.81 0.74 12.12 9.67 0.77 12.60 9.53
11.26 9.96 0.78 11.88 9.82 0.80 12.36 9.67
10.96 10.01 0.80 11.67 9.87 0.82 12.00 9.72
10.71 9.99 0.81 11.42 9.84 0.84 11.84 9.70
10.46 9.96 0.83 11.17 9.82 0.85 11.69 9.67
10.21 9.93 0.84 10.92 9.79 0.86 11.44 9.64
9.96 9.91 0.84 10.67 9.77 0.87 11.19 9.62
9.60 9.93 0.85 10.32 9.78 0.88 10.80 9.64
9.24 9.96 0.86 9.91 9.81 0.88 10.40 9.66

PI
0.69
0.71
0.74
0.79
0.82
0.85
0.86
0.88
0.89
0.90
0.91
0.91

86 / 72
TC SHC PI
14.04 9.08 0.72
13.86 9.15 0.74
13.68 9.22 0.77
13.50 9.34 0.82
13.32 9.48 0.86
13.10 9.53 0.88
12.85 9.50 0.90
12.60 9.48 0.91
12.35 9.45 0.92
12.10 9.43 0.93
11.70 9.44 0.94
11.27 9.47 0.95

PI
0.55
0.57
0.59
0.63
0.66
0.68
0.69
0.70
0.71
0.72
0.72
0.73

TC
10.53
10.40
10.26
10.13
9.99
9.83
9.64
9.45
9.26
9.08
8.78
8.45

90 / 75
TC SHC PI
15.00 8.94 0.74
14.88 9.01 0.76
14.64 9.08 0.79
14.42 9.20 0.85
14.13 9.34 0.88
13.81 9.38 0.91
13.56 9.36 0.93
13.31 9.33 0.94
13.07 9.31 0.95
12.82 9.29 0.96
12.36 9.30 0.97
11.94 9.33 0.97

AS-W093B1B8 (LSN091HSV3/LSU091HSV3)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
8.10 7.83
8.00 7.89
7.79 7.95
7.58 8.05
7.37 8.17
7.15 8.21
6.96 8.19
6.77 8.17
6.59 8.15
6.40 8.13
6.21 8.14
5.92 8.17

PI
0.49
0.50
0.52
0.56
0.58
0.60
0.61
0.62
0.63
0.64
0.64
0.64

68 / 57
TC SHC PI
8.64 7.71 0.50
8.54 7.78 0.52
8.33 7.84 0.54
8.12 7.93 0.58
7.91 8.05 0.60
7.68 8.09 0.62
7.50 8.07 0.63
7.31 8.05 0.64
7.12 8.03 0.65
6.94 8.01 0.65
6.75 8.02 0.66
6.42 8.05 0.66

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
9.18 7.60 0.52 9.54 7.49 0.53 9.81 7.38
9.08 7.66 0.53 9.45 7.55 0.55 9.72 7.44
8.87 7.72 0.56 9.27 7.61 0.57 9.63 7.49
8.66 7.81 0.60 9.09 7.70 0.61 9.45 7.59
8.45 7.93 0.62 8.91 7.82 0.64 9.27 7.70
8.22 7.97 0.64 8.75 7.86 0.66 9.00 7.74
8.03 7.95 0.65 8.57 7.84 0.67 8.88 7.72
7.84 7.93 0.66 8.38 7.82 0.68 8.77 7.70
7.66 7.91 0.67 8.19 7.79 0.69 8.58 7.68
7.47 7.89 0.68 8.01 7.78 0.70 8.39 7.66
7.20 7.91 0.68 7.74 7.79 0.70 8.10 7.67
6.93 7.93 0.68 7.44 7.81 0.71 7.80 7.70

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
SHC : Sensible Heating Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

65

86 / 72
SHC PI
7.23 0.57
7.29 0.59
7.34 0.62
7.43 0.66
7.55 0.69
7.59 0.71
7.57 0.72
7.55 0.73
7.52 0.74
7.51 0.75
7.52 0.75
7.54 0.76

TC
11.25
11.16
10.98
10.82
10.60
10.36
10.17
9.99
9.80
9.61
9.27
8.96

90 / 75
SHC PI
7.12 0.59
7.18 0.61
7.23 0.63
7.32 0.68
7.43 0.71
7.47 0.73
7.45 0.74
7.43 0.75
7.41 0.76
7.40 0.77
7.41 0.78
7.43 0.78

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2.
Indicates reference data. When operating at this temperature,
these values can be different by discontinuous operation.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:80F(26.7C) DB / 67F(19.4C) WB
- Outdoor Air Temperature
:95F(35.0C) DB / 75F(23.9C) WB

Inverter Single

6RMI0-06A

Capacity tables

AS-W123B1B8 (LSN121HSV3/LSU121HSV3)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
10.08 9.06
9.95 9.14
9.69 9.21
9.43 9.32
9.17 9.46
8.90 9.51
8.66 9.49
8.43 9.46
8.20 9.43
7.96 9.41
7.73 9.43
7.36 9.46

PI
0.64
0.66
0.69
0.74
0.77
0.79
0.81
0.82
0.83
0.84
0.84
0.85

68 / 57
TC SHC PI
10.75 8.93 0.66
10.63 9.00 0.68
10.36 9.07 0.71
10.10 9.18 0.76
9.84 9.32 0.79
9.56 9.37 0.82
9.33 9.35 0.83
9.10 9.32 0.85
8.86 9.29 0.85
8.63 9.28 0.86
8.40 9.29 0.87
7.99 9.32 0.87

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
11.42 8.80 0.68 11.87 8.67 0.70 12.21 8.54
11.30 8.87 0.70 11.76 8.74 0.72 12.10 8.61
11.04 8.94 0.73 11.54 8.80 0.76 11.98 8.67
10.77 9.05 0.78 11.31 8.91 0.81 11.76 8.78
10.51 9.18 0.82 11.09 9.05 0.84 11.54 8.92
10.23 9.23 0.84 10.89 9.09 0.87 11.20 8.96
10.00 9.21 0.86 10.66 9.07 0.88 11.05 8.94
9.76 9.18 0.87 10.43 9.05 0.90 10.91 8.91
9.53 9.16 0.88 10.20 9.02 0.91 10.68 8.89
9.30 9.14 0.89 9.96 9.00 0.92 10.44 8.87
8.96 9.15 0.90 9.63 9.02 0.93 10.08 8.88
8.62 9.18 0.90 9.25 9.04 0.93 9.71 8.91

PI
0.73
0.75
0.78
0.83
0.87
0.90
0.91
0.93
0.94
0.95
0.95
0.96

86 / 72
TC SHC PI
13.10 8.37 0.76
12.94 8.44 0.78
12.77 8.50 0.81
12.60 8.61 0.87
12.43 8.74 0.90
12.23 8.78 0.93
11.99 8.76 0.95
11.76 8.74 0.96
11.53 8.71 0.97
11.30 8.69 0.98
10.92 8.70 0.99
10.51 8.73 1.00

PI
1.17
1.21
1.26
1.35
1.40
1.45
1.47
1.50
1.51
1.53
1.54
1.55

TC
21.29
21.02
20.75
20.48
20.20
19.87
19.49
19.11
18.73
18.35
17.75
17.09

90 / 75
TC SHC PI
14.00 8.24 0.78
13.89 8.31 0.80
13.66 8.37 0.84
13.46 8.48 0.89
13.19 8.61 0.93
12.89 8.65 0.96
12.66 8.63 0.98
12.43 8.60 0.99
12.19 8.58 1.00
11.96 8.56 1.01
11.54 8.57 1.02
11.14 8.60 1.03

AS-W183C2B8 (LSN181HSV3/LSU181HSV3)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
16.38 14.55
16.17 14.66
15.75 14.78
15.33 14.96
14.91 15.19
14.46 15.26
14.08 15.22
13.70 15.18
13.32 15.14
12.94 15.11
12.56 15.13
11.96 15.18

PI
1.04
1.07
1.11
1.19
1.24
1.28
1.30
1.32
1.34
1.35
1.36
1.37

68 / 57
TC SHC PI
17.47 14.33 1.07
17.27 14.45 1.10
16.84 14.56 1.15
16.42 14.74 1.23
16.00 14.96 1.28
15.54 15.04 1.32
15.16 15.00 1.34
14.78 14.96 1.36
14.40 14.92 1.38
14.02 14.89 1.39
13.65 14.91 1.41
12.99 14.95 1.41

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
18.56 14.12 1.10 19.29 13.91 1.14 19.84 13.71
18.36 14.23 1.14 19.11 14.02 1.17 19.66 13.81
17.93 14.34 1.18 18.75 14.13 1.22 19.47 13.92
17.51 14.52 1.27 18.38 14.30 1.31 19.11 14.09
17.08 14.74 1.32 18.02 14.52 1.36 18.75 14.31
16.62 14.81 1.36 17.70 14.60 1.40 18.20 14.38
16.24 14.78 1.38 17.32 14.56 1.43 17.96 14.34
15.86 14.74 1.41 16.95 14.52 1.45 17.73 14.31
15.49 14.70 1.42 16.57 14.48 1.47 17.35 14.26
15.11 14.67 1.44 16.19 14.45 1.48 16.97 14.24
14.56 14.69 1.45 15.65 14.47 1.49 16.38 14.26
14.01 14.73 1.46 15.04 14.51 1.50 15.78 14.30

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
SHC : Sensible Heating Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

86 / 72
SHC PI
13.43 1.22
13.54 1.25
13.64 1.31
13.81 1.40
14.02 1.46
14.09 1.50
14.06 1.53
14.02 1.56
13.98 1.57
13.95 1.59
13.97 1.60
14.01 1.61

TC
22.75
22.57
22.20
21.87
21.44
20.95
20.57
20.19
19.82
19.44
18.75
18.11

90 / 75
SHC PI
13.23 1.26
13.33 1.29
13.44 1.35
13.60 1.44
13.81 1.50
13.88 1.55
13.85 1.58
13.81 1.60
13.77 1.62
13.74 1.64
13.76 1.65
13.80 1.66

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2.
Indicates reference data. When operating at this temperature,
these values can be different by discontinuous operation.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:80F(26.7C) DB / 67F(19.4C) WB
- Outdoor Air Temperature
:95F(35.0C) DB / 75F(23.9C) WB

Inverter Single

66

Capacity tables

6RMI0-06A

AS-W243D8B8 (LSN240HSV3/LSU240HSV3)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
19.80 18.03
19.55 18.17
19.03 18.31
18.53 18.54
18.02 18.82
17.47 18.91
17.02 18.86
16.56 18.82
16.10 18.76
15.64 18.72
15.18 18.75
14.46 18.81

PI
1.26
1.30
1.36
1.45
1.51
1.56
1.58
1.61
1.63
1.64
1.66
1.67

68 / 57
TC SHC PI
21.12 17.76 1.30
20.87 17.90 1.34
20.36 18.04 1.40
19.85 18.26 1.49
19.34 18.54 1.56
18.78 18.63 1.61
18.33 18.59 1.63
17.87 18.54 1.66
17.41 18.48 1.68
16.95 18.45 1.69
16.50 18.47 1.71
15.70 18.53 1.72

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
22.44 17.50 1.34 23.32 17.24 1.38 23.98 16.99
22.20 17.64 1.38 23.10 17.38 1.42 23.76 17.12
21.68 17.77 1.44 22.66 17.51 1.49 23.54 17.25
21.16 17.99 1.54 22.22 17.73 1.59 23.10 17.46
20.65 18.27 1.61 21.78 18.00 1.66 22.66 17.73
20.09 18.36 1.66 21.40 18.09 1.71 22.00 17.82
19.63 18.31 1.68 20.94 18.04 1.74 21.71 17.77
19.18 18.26 1.71 20.48 17.99 1.76 21.43 17.73
18.72 18.21 1.73 20.03 17.94 1.78 20.97 17.68
18.26 18.18 1.75 19.57 17.91 1.80 20.52 17.64
17.60 18.20 1.76 18.92 17.93 1.82 19.80 17.67
16.94 18.25 1.77 18.18 17.98 1.83 19.07 17.72

PI
1.43
1.47
1.53
1.64
1.71
1.76
1.79
1.82
1.84
1.86
1.87
1.88

86 / 72
TC SHC PI
25.74 16.65 1.48
25.41 16.78 1.53
25.08 16.91 1.59
24.75 17.11 1.70
24.42 17.38 1.78
24.02 17.46 1.83
23.56 17.42 1.86
23.10 17.37 1.89
22.64 17.32 1.91
22.19 17.29 1.93
21.45 17.31 1.95
20.65 17.36 1.96

PI
2.43
2.50
2.61
2.79
2.91
3.00
3.05
3.10
3.14
3.17
3.20
3.21

TC
35.10
34.65
34.20
33.75
33.30
32.75
32.13
31.50
30.88
30.26
29.25
28.16

90 / 75
TC SHC PI
27.50 16.40 1.53
27.28 16.52 1.57
26.84 16.65 1.64
26.44 16.86 1.75
25.91 17.12 1.83
25.33 17.20 1.89
24.87 17.16 1.92
24.41 17.11 1.95
23.95 17.06 1.97
23.50 17.03 1.99
22.66 17.05 2.01
21.89 17.10 2.02

AS-W303D8B8 (LSN307HV3/LSU307HV3)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
27.00 25.19
26.65 25.39
25.96 25.58
25.27 25.90
24.57 26.30
23.83 26.43
23.20 26.36
22.58 26.29
21.96 26.22
21.33 26.16
20.70 26.20
19.72 26.28

PI
2.15
2.21
2.31
2.47
2.58
2.66
2.70
2.74
2.78
2.80
2.83
2.84

68 / 57
TC SHC PI
28.80 24.82 2.22
28.46 25.01 2.28
27.76 25.21 2.38
27.06 25.52 2.55
26.37 25.91 2.66
25.61 26.04 2.74
24.99 25.97 2.78
24.37 25.90 2.83
23.74 25.83 2.86
23.12 25.78 2.89
22.50 25.81 2.92
21.41 25.89 2.93

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
30.60 24.45 2.29 31.80 24.09 2.36 32.70 23.74
30.27 24.64 2.35 31.50 24.28 2.43 32.40 23.92
29.56 24.83 2.46 30.90 24.47 2.53 32.10 24.11
28.86 25.14 2.63 30.30 24.77 2.71 31.50 24.40
28.16 25.52 2.74 29.70 25.15 2.82 30.90 24.78
27.40 25.65 2.82 29.18 25.27 2.91 30.00 24.90
26.77 25.59 2.87 28.56 25.21 2.96 29.61 24.84
26.15 25.52 2.92 27.93 25.14 3.01 29.22 24.77
25.53 25.45 2.95 27.31 25.07 3.04 28.60 24.70
24.90 25.40 2.98 26.69 25.02 3.07 27.98 24.65
24.00 25.43 3.01 25.80 25.06 3.10 27.00 24.68
23.10 25.51 3.02 24.78 25.13 3.11 26.00 24.76

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
SHC : Sensible Heating Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

67

86 / 72
SHC PI
23.26 2.53
23.44 2.60
23.62 2.71
23.91 2.90
24.28 3.03
24.40 3.12
24.34 3.17
24.28 3.22
24.21 3.26
24.16 3.29
24.19 3.32
24.26 3.34

TC
37.50
37.20
36.60
36.05
35.33
34.53
33.91
33.29
32.66
32.04
30.90
29.85

90 / 75
SHC PI
22.91 2.60
23.09 2.68
23.27 2.80
23.56 2.99
23.92 3.12
24.04 3.21
23.97 3.27
23.91 3.32
23.84 3.36
23.80 3.39
23.83 3.42
23.90 3.44

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2.
Indicates reference data. When operating at this temperature,
these values can be different by discontinuous operation.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:80F(26.7C) DB / 67F(19.4C) WB
- Outdoor Air Temperature
:95F(35.0C) DB / 75F(23.9C) WB

Inverter Single

6RMI0-06A

Capacity tables

AS-W363D8B8 (LSN360HV3/LSU360HV3)
Outdoor Air
Temperature
DB
70
75
80
85
90
95
100
105
110
115
118
122

64 / 53
TC SHC
29.70 27.38
29.32 27.59
28.55 27.80
27.79 28.15
27.03 28.58
26.21 28.72
25.53 28.65
24.84 28.57
24.15 28.49
23.47 28.43
22.77 28.47
21.69 28.56

PI
2.90
2.98
3.11
3.33
3.47
3.58
3.64
3.70
3.74
3.77
3.81
3.83

68 / 57
TC SHC PI
31.68 26.97 2.99
31.31 27.18 3.07
30.53 27.39 3.21
29.77 27.73 3.43
29.00 28.15 3.58
28.17 28.30 3.69
27.49 28.22 3.75
26.80 28.15 3.81
26.12 28.07 3.85
25.43 28.01 3.89
24.75 28.05 3.93
23.55 28.14 3.95

Indoor Air Temperature : DB / WB


72 / 61
77 / 64
80 / 67
TC SHC PI TC SHC PI TC SHC
33.66 26.57 3.08 34.98 26.18 3.18 35.97 25.79
33.29 26.78 3.17 34.65 26.38 3.27 35.64 26.00
32.52 26.99 3.31 33.99 26.59 3.41 35.31 26.20
31.75 27.32 3.54 33.33 26.92 3.64 34.65 26.52
30.98 27.74 3.69 32.67 27.33 3.80 33.99 26.92
30.14 27.88 3.80 32.10 27.47 3.92 33.00 27.06
29.45 27.81 3.86 31.41 27.40 3.98 32.57 26.99
28.76 27.73 3.93 30.73 27.32 4.05 32.14 26.92
28.08 27.65 3.97 30.04 27.25 4.10 31.46 26.84
27.39 27.60 4.01 29.36 27.19 4.13 30.77 26.79
26.40 27.64 4.05 28.38 27.23 4.17 29.70 26.83
25.40 27.72 4.07 27.26 27.31 4.19 28.60 26.91

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
SHC : Sensible Heating Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

PI
3.27
3.37
3.51
3.76
3.92
4.04
4.11
4.18
4.22
4.26
4.30
4.32

86 / 72
TC SHC PI
38.61 25.28 3.41
38.12 25.48 3.50
37.62 25.67 3.66
37.13 25.99 3.91
36.63 26.39 4.08
36.03 26.52 4.20
35.34 26.45 4.27
34.65 26.38 4.34
33.97 26.31 4.39
33.28 26.25 4.43
32.18 26.29 4.47
30.98 26.37 4.50

90 / 75
TC SHC
41.25 24.90
40.92 25.09
40.26 25.29
39.66 25.60
38.87 25.99
37.99 26.12
37.30 26.05
36.62 25.99
35.93 25.91
35.24 25.86
33.99 25.90
32.84 25.97

PI
3.51
3.61
3.77
4.02
4.20
4.33
4.40
4.47
4.52
4.57
4.61
4.63

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2.
Indicates reference data. When operating at this temperature,
these values can be different by discontinuous operation.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:80F(26.7C) DB / 67F(19.4C) WB
- Outdoor Air Temperature
:95F(35.0C) DB / 75F(23.9C) WB

Inverter Single

68

Capacity tables

6RMI0-06A

7.2 Heating Capacity


AS-W093MMM9(LSN090HYV/LSU090HYV)
Outdoor Air
Temperature
F DB
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
6.70
6.84
7.79
8.89
10.15
10.47
11.57
11.69
11.96
12.21
12.44
12.62
12.73

64
PI
0.61
0.63
0.66
0.69
0.72
0.73
0.75
0.76
0.77
0.78
0.80
0.81
0.82

TC
6.50
6.63
7.55
8.62
9.85
10.15
11.22
11.34
11.59
11.84
12.07
12.23
12.35

PI
0.61
0.63
0.65
0.68
0.71
0.72
0.75
0.75
0.76
0.78
0.79
0.80
0.81

Indoor Air Temperature : DB


68
70
72
TC
PI
TC
PI
TC
6.43
0.61
6.37
0.60
6.32
6.57
0.63
6.50
0.62
6.45
7.47
0.65
7.40
0.64
7.34
8.53
0.68
8.45
0.67
8.39
9.75
0.71
9.65
0.70
9.58
10.05
0.72
9.95
0.71
9.87
11.11
0.75
11.00 0.74
10.92
11.22
0.75
11.11 0.75
11.03
11.48
0.76
11.36 0.75
11.28
11.72
0.78
11.61 0.77
11.52
11.94
0.79
11.83 0.78
11.73
12.11
0.80
11.99 0.79
11.90
12.22
0.81
12.10 0.80
12.01

75
PI
0.60
0.62
0.64
0.67
0.70
0.71
0.74
0.75
0.75
0.77
0.78
0.79
0.80

TC
6.19
6.32
7.20
8.22
9.38
9.68
10.70
10.80
11.05
11.29
11.50
11.66
11.77

86
PI
0.60
0.61
0.64
0.67
0.70
0.70
0.73
0.74
0.75
0.76
0.77
0.78
0.79

TC
6.05
6.17
7.02
8.02
9.16
9.45
10.44
10.55
10.79
11.02
11.23
11.38
11.49

PI
0.60
0.61
0.64
0.67
0.70
0.70
0.73
0.74
0.75
0.76
0.77
0.78
0.79

AS-W123MMM9(LSN120HYV/LSU120HYV)
Outdoor Air
Temperature
F DB
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
9.07
9.26
10.27
11.45
12.80
13.13
14.31
14.45
14.78
15.10
15.38
15.60
15.74

64
PI
0.82
0.85
0.87
0.90
0.94
0.95
0.98
0.99
1.00
1.02
1.03
1.05
1.06

TC
8.80
8.98
9.96
11.10
12.41
12.73
13.88
14.02
14.33
14.64
14.92
15.13
15.26

68
PI
0.81
0.84
0.86
0.90
0.93
0.94
0.97
0.98
0.99
1.01
1.02
1.04
1.05

TC
8.71
8.89
9.86
10.99
12.28
12.60
13.74
13.87
14.19
14.49
14.77
14.97
15.11

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

69

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
0.81
8.62
0.81
8.56
0.84
8.80
0.83
8.73
0.86
9.76
0.86
9.69
0.90
10.88 0.89
10.80
0.93
12.16 0.92
12.07
0.94
12.48 0.93
12.38
0.97
13.60 0.96
13.50
0.98
13.74 0.97
13.63
0.99
14.05 0.98
13.94
1.01
14.35 1.00
14.24
1.02
14.62 1.01
14.51
1.04
14.82 1.03
14.71
1.05
14.96 1.04
14.85

75
PI
0.81
0.83
0.86
0.89
0.92
0.93
0.96
0.97
0.98
1.00
1.01
1.03
1.04

TC
8.39
8.56
9.49
10.58
11.82
12.14
13.23
13.36
13.66
13.95
14.22
14.42
14.55

86
PI
0.80
0.82
0.85
0.88
0.91
0.92
0.95
0.96
0.97
0.99
1.00
1.02
1.03

TC
8.19
8.35
9.27
10.33
11.54
11.85
12.91
13.04
13.34
13.62
13.88
14.07
14.20

PI
0.80
0.82
0.85
0.88
0.91
0.92
0.95
0.96
0.97
0.99
1.00
1.02
1.03

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2. Direct interpolation is permissible. Do not extrapolate
3. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:70F(21.1C) DB / 60F(15.6C) WB
- Outdoor Air Temperature
: 47F(8.3C) DB / 43F(6.1C) WB

Inverter Single

6RMI0-06A

Capacity tables

AS-W093B1Y9(LSN091HSV2/LSU091HSV2), AS-W093BRM9(LAN090HSV2/LAU090HSV2)
Outdoor Air
Temperature
F DB
6
10
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
5
9
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
6.61
6.90
7.12
7.26
8.08
9.04
10.13
10.41
11.36
11.48
11.74
11.99
12.22
12.39
12.50

64
PI
0.65
0.68
0.68
0.70
0.71
0.71
0.71
0.71
0.71
0.72
0.73
0.74
0.75
0.76
0.77

TC
6.41
6.69
6.90
7.04
7.84
8.76
9.83
10.09
11.02
11.13
11.38
11.63
11.85
12.01
12.12

68
PI
0.65
0.67
0.68
0.70
0.70
0.70
0.70
0.70
0.71
0.71
0.72
0.74
0.75
0.76
0.76

TC
6.34
6.62
6.83
6.97
7.76
8.68
9.73
9.99
10.91
11.02
11.27
11.51
11.73
11.89
12.00

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
0.65
6.28
0.64
6.23
0.67
6.56
0.66
6.50
0.68
6.76
0.67
6.71
0.70
6.90
0.69
6.85
0.70
7.68
0.69
7.62
0.70
8.59
0.69
8.52
0.70
9.63
0.70
9.56
0.70
9.89
0.70
9.81
0.71
10.80 0.70
10.72
0.71
10.91 0.71
10.82
0.72
11.16 0.71
11.07
0.74
11.39 0.73
11.31
0.75
11.61 0.74
11.52
0.76
11.77 0.75
11.68
0.76
11.88 0.76
11.79

75
PI
0.64
0.66
0.67
0.69
0.69
0.69
0.70
0.70
0.70
0.71
0.71
0.73
0.74
0.75
0.76

TC
6.11
6.37
6.58
6.71
7.47
8.35
9.36
9.62
10.50
10.61
10.85
11.08
11.29
11.45
11.55

86
PI
0.64
0.66
0.66
0.68
0.69
0.69
0.69
0.69
0.69
0.70
0.71
0.72
0.73
0.74
0.75

TC
5.96
6.22
6.42
6.55
7.29
8.15
9.14
9.39
10.25
10.36
10.59
10.82
11.02
11.18
11.28

PI
0.64
0.66
0.66
0.68
0.69
0.69
0.69
0.69
0.69
0.70
0.71
0.72
0.73
0.74
0.75

AS-W123B1Y9(LSN121HSV2/LSU121HSV2), AS-W123BRM9(LAN120HSV2/LAU120HSV2)
Outdoor Air
Temperature
F DB
6
10
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
5
9
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
6.61
6.90
7.12
7.26
8.30
10.63
12.70
13.22
14.00
14.14
14.46
14.76
15.04
15.25
15.39

64
PI
0.85
0.88
0.89
0.92
0.93
0.97
1.00
1.01
1.02
1.03
1.04
1.06
1.08
1.09
1.10

TC
6.41
6.69
6.90
7.04
8.04
10.31
12.31
12.82
13.57
13.71
14.02
14.32
14.59
14.79
14.93

68
PI
0.85
0.87
0.88
0.91
0.92
0.96
0.99
1.00
1.01
1.02
1.03
1.05
1.07
1.08
1.09

TC
6.34
6.62
6.83
6.97
7.96
10.20
12.19
12.69
13.43
13.57
13.88
14.17
14.44
14.64
14.78

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
0.85
6.28
0.84
6.23
0.87
6.56
0.86
6.50
0.88
6.76
0.87
6.71
0.91
6.90
0.90
6.85
0.92
7.88
0.92
7.82
0.96
10.10 0.95
10.02
0.99
12.07 0.98
11.98
1.00
12.56 0.99
12.47
1.01
13.30 1.00
13.20
1.02
13.43 1.01
13.33
1.03
13.74 1.02
13.63
1.05
14.03 1.04
13.92
1.07
14.30 1.06
14.19
1.08
14.50 1.07
14.39
1.09
14.63 1.08
14.52

75
PI
0.84
0.86
0.87
0.90
0.92
0.95
0.98
0.99
1.00
1.01
1.02
1.04
1.06
1.07
1.08

TC
6.11
6.37
6.58
6.71
7.67
9.82
11.74
12.22
12.93
13.06
13.36
13.64
13.90
14.10
14.23

86
PI
0.83
0.86
0.86
0.89
0.91
0.94
0.97
0.98
0.99
1.00
1.01
1.03
1.04
1.06
1.07

TC
5.96
6.22
6.42
6.55
7.48
9.59
11.46
11.92
12.63
12.75
13.04
13.32
13.57
13.76
13.89

PI
0.83
0.86
0.86
0.89
0.91
0.94
0.97
0.98
0.99
1.00
1.01
1.03
1.04
1.06
1.07

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2. Direct interpolation is permissible. Do not extrapolate
3. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:70F(21.1C) DB / 60F(15.6C) WB
- Outdoor Air Temperature
: 47F(8.3C) DB / 43F(6.1C) WB

Inverter Single

70

Capacity tables

6RMI0-06A

AS-W183C2Y9(LSN181HSV2/LSU181HSV2), AS-W183BRM9(LAN180HSV2/LAU180HSV2)
Outdoor Air
Temperature
F DB
6
10
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
5
9
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
13.41
14.00
14.44
14.73
16.03
18.94
21.53
22.18
23.15
23.38
23.91
24.42
24.89
25.23
25.46

64
PI
0.85
0.88
0.89
0.92
1.05
1.36
1.63
1.69
1.80
1.81
1.83
1.87
1.89
1.92
1.94

TC
13.00
13.57
14.00
14.28
15.54
18.37
20.88
21.51
22.45
22.67
23.19
23.68
24.13
24.47
24.69

68
PI
0.85
0.87
0.88
0.91
1.04
1.34
1.61
1.68
1.78
1.80
1.81
1.85
1.88
1.90
1.92

TC
12.87
13.43
13.86
14.14
15.38
18.18
20.67
21.29
22.22
22.44
22.95
23.44
23.89
24.22
24.44

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
0.85
12.74 0.84
12.64
0.87
13.30 0.86
13.20
0.88
13.72 0.87
13.62
0.91
14.00 0.90
13.89
1.04
15.23 1.03
15.11
1.34
18.00 1.33
17.86
1.61
20.46 1.59
20.31
1.68
21.08 1.66
20.92
1.78
22.00 1.76
21.83
1.80
22.22 1.78
22.05
1.81
22.73 1.80
22.55
1.85
23.21 1.83
23.03
1.88
23.65 1.86
23.47
1.90
23.98 1.88
23.80
1.92
24.20 1.90
24.02

75
PI
0.84
0.86
0.87
0.90
1.03
1.33
1.59
1.66
1.76
1.78
1.80
1.83
1.86
1.88
1.90

TC
12.39
12.93
13.34
13.61
14.81
17.50
19.90
20.50
21.39
21.61
22.10
22.57
23.00
23.32
23.53

PI
1.48
1.53
1.54
1.59
1.76
2.13
2.46
2.55
2.67
2.70
2.72
2.78
2.82
2.86
2.88

TC
15.93
16.63
17.15
17.50
18.94
22.17
25.04
25.76
26.84
27.11
27.72
28.32
28.85
29.25
29.52

86
PI
0.83
0.86
0.86
0.89
1.02
1.32
1.58
1.64
1.74
1.76
1.78
1.81
1.84
1.86
1.88

TC
12.09
12.63
13.02
13.29
14.46
17.09
19.42
20.01
20.88
21.09
21.57
22.03
22.45
22.76
22.97

PI
1.46
1.51
1.53
1.57
1.74
2.11
2.44
2.52
2.64
2.67
2.70
2.75
2.79
2.83
2.85

TC
15.55
16.23
16.75
17.09
18.49
21.64
24.45
25.15
26.20
26.46
27.07
27.64
28.17
28.56
28.82

PI
0.83
0.86
0.86
0.89
1.02
1.32
1.58
1.64
1.74
1.76
1.78
1.81
1.84
1.86
1.88

AS-W243CRM9(LAN240HSV2/LAU240HSV2)
Outdoor Air
Temperature
F DB
6
10
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
5
9
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
17.24
17.99
18.56
18.94
20.49
23.99
27.10
27.88
29.04
29.33
30.00
30.64
31.22
31.66
31.95

64
PI
1.51
1.56
1.57
1.62
1.79
2.17
2.51
2.60
2.72
2.75
2.78
2.83
2.87
2.91
2.94

TC
16.71
17.45
18.00
18.37
19.87
23.26
26.28
27.03
28.16
28.44
29.09
29.71
30.27
30.70
30.98

68
PI
1.49
1.54
1.56
1.61
1.77
2.15
2.49
2.57
2.70
2.72
2.75
2.80
2.85
2.89
2.91

TC
16.54
17.27
17.82
18.18
19.67
23.03
26.01
26.76
27.88
28.15
28.80
29.41
29.97
30.38
30.66

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

71

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
1.49
16.38 1.48
16.25
1.54
17.10 1.53
16.97
1.56
17.64 1.54
17.51
1.61
18.00 1.59
17.86
1.77
19.48 1.76
19.33
2.15
22.80 2.13
22.63
2.49
25.75 2.46
25.56
2.57
26.49 2.55
26.29
2.70
27.60 2.67
27.39
2.72
27.88 2.70
27.66
2.75
28.51 2.72
28.29
2.80
29.12 2.78
28.90
2.85
29.67 2.82
29.44
2.89
30.08 2.86
29.85
2.91
30.36 2.88
30.13

75

86
PI
1.46
1.51
1.53
1.57
1.74
2.11
2.44
2.52
2.64
2.67
2.70
2.75
2.79
2.83
2.85

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2. Direct interpolation is permissible. Do not extrapolate
3. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:70F(21.1C) DB / 60F(15.6C) WB
- Outdoor Air Temperature
: 47F(8.3C) DB / 43F(6.1C) WB

Inverter Single

6RMI0-06A

Capacity tables

AS-W243DGY9(LSN240HSV2/LSU240HSV2)
Outdoor Air
Temperature
F DB
6
10
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
5
9
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
16.57
17.29
17.84
18.20
19.87
23.62
26.96
27.79
29.04
29.33
30.00
30.64
31.22
31.66
31.95

64
PI
1.83
1.89
1.91
1.97
2.04
2.20
2.34
2.37
2.43
2.45
2.48
2.52
2.56
2.60
2.62

TC
16.06
16.77
17.30
17.65
19.27
22.91
26.14
26.95
28.16
28.44
29.09
29.71
30.27
30.70
30.98

68
PI
1.81
1.87
1.89
1.95
2.02
2.18
2.32
2.35
2.40
2.43
2.45
2.50
2.54
2.57
2.60

TC
15.90
16.60
17.12
17.47
19.07
22.67
25.88
26.68
27.88
28.15
28.80
29.41
29.97
30.38
30.66

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
1.81
15.74 1.79
15.62
1.87
16.44 1.85
16.31
1.89
16.95 1.87
16.82
1.95
17.30 1.93
17.17
2.02
18.88 2.00
18.74
2.18
22.45 2.16
22.28
2.32
25.62 2.29
25.42
2.35
26.41 2.33
26.21
2.40
27.60 2.38
27.39
2.43
27.88 2.40
27.66
2.45
28.51 2.43
28.29
2.50
29.12 2.48
28.90
2.54
29.67 2.51
29.44
2.57
30.08 2.55
29.85
2.60
30.36 2.57
30.13

75
PI
1.79
1.85
1.87
1.93
2.00
2.16
2.29
2.33
2.38
2.40
2.43
2.48
2.51
2.55
2.57

TC
15.31
15.98
16.49
16.82
18.36
21.83
24.91
25.68
26.84
27.11
27.72
28.32
28.85
29.25
29.52

PI
2.28
2.35
2.38
2.45
2.55
2.78
2.98
3.03
3.10
3.13
3.16
3.22
3.27
3.32
3.35

TC
18.05
18.85
19.44
19.84
21.57
25.48
28.95
29.82
31.12
31.43
32.14
32.83
33.45
33.92
34.23

86
PI
1.78
1.83
1.85
1.91
1.98
2.13
2.27
2.30
2.36
2.38
2.40
2.45
2.49
2.52
2.54

TC
14.95
15.60
16.09
16.42
17.93
21.31
24.32
25.07
26.20
26.46
27.07
27.64
28.17
28.56
28.82

PI
2.26
2.33
2.35
2.43
2.52
2.75
2.95
2.99
3.07
3.10
3.13
3.19
3.24
3.28
3.31

TC
17.62
18.40
18.98
19.37
21.06
24.87
28.26
29.11
30.38
30.68
31.38
32.05
32.66
33.11
33.42

PI
1.78
1.83
1.85
1.91
1.98
2.13
2.27
2.30
2.36
2.38
2.40
2.45
2.49
2.52
2.54

AS-W303DGY9(LSN307HV2/LSU307HV2)
Outdoor Air
Temperature
F DB
6
10
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
5
9
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
19.53
20.39
21.04
21.47
23.34
27.57
31.33
32.26
33.67
34.01
34.78
35.52
36.20
36.70
37.04

64
PI
2.32
2.40
2.42
2.50
2.60
2.83
3.03
3.09
3.16
3.19
3.23
3.29
3.34
3.38
3.41

TC
18.94
19.77
20.40
20.81
22.64
26.73
30.37
31.29
32.65
32.98
33.73
34.45
35.10
35.59
35.92

68
PI
2.30
2.38
2.40
2.47
2.58
2.80
3.00
3.06
3.13
3.16
3.19
3.26
3.30
3.35
3.38

TC
18.75
19.57
20.19
20.60
22.41
26.46
30.07
30.97
32.32
32.64
33.39
34.10
34.74
35.23
35.55

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
2.30
18.56 2.28
18.42
2.38
19.38 2.35
19.23
2.40
19.99 2.38
19.84
2.47
20.40 2.45
20.24
2.58
22.18 2.55
22.02
2.80
26.20 2.78
26.00
3.00
29.77 2.98
29.54
3.06
30.66 3.03
30.43
3.13
32.00 3.10
31.76
3.16
32.32 3.13
32.07
3.19
33.06 3.16
32.80
3.26
33.76 3.22
33.50
3.30
34.40 3.27
34.14
3.35
34.88 3.32
34.61
3.38
35.20 3.35
34.93

75

86
PI
2.26
2.33
2.35
2.43
2.52
2.75
2.95
2.99
3.07
3.10
3.13
3.19
3.24
3.28
3.31

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2. Direct interpolation is permissible. Do not extrapolate
3. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:70F(21.1C) DB / 60F(15.6C) WB
- Outdoor Air Temperature
: 47F(8.3C) DB / 43F(6.1C) WB

Inverter Single

72

Capacity tables

6RMI0-06A

AS-W363DGY9(LSN360HV2/LSU360HV2)
Outdoor Air
Temperature
F DB
6
10
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
5
9
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
22.22
23.19
23.92
24.41
26.94
29.88
33.25
34.09
37.04
37.41
38.26
39.08
39.82
40.37
40.74

64
PI
2.66
2.74
2.77
2.86
3.07
3.32
3.60
3.67
3.92
3.96
4.00
4.07
4.13
4.19
4.23

TC
21.54
22.49
23.20
23.67
26.12
28.98
32.24
33.06
35.92
36.28
37.10
37.89
38.61
39.15
39.51

68
PI
2.63
2.71
2.74
2.83
3.04
3.28
3.56
3.63
3.88
3.92
3.96
4.03
4.09
4.15
4.19

TC
21.32
22.26
22.96
23.43
25.86
28.68
31.92
32.72
35.55
35.91
36.73
37.51
38.22
38.75
39.11

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
2.63
21.11 2.60
20.95
2.71
22.04 2.69
21.87
2.74
22.74 2.72
22.56
2.83
23.20 2.80
23.02
3.04
25.60 3.01
25.40
3.28
28.40 3.25
28.18
3.56
31.60 3.53
31.36
3.63
32.40 3.60
32.15
3.88
35.20 3.84
34.93
3.92
35.55 3.88
35.28
3.96
36.36 3.92
36.08
4.03
37.14 3.99
36.85
4.09
37.84 4.05
37.55
4.15
38.37 4.11
38.07
4.19
38.72 4.15
38.42

75
PI
2.60
2.69
2.72
2.80
3.01
3.25
3.53
3.60
3.84
3.88
3.92
3.99
4.05
4.11
4.15

TC
20.53
21.43
22.11
22.56
24.89
27.62
30.73
31.51
34.23
34.57
35.36
36.11
36.80
37.31
37.65

PI
0.65
0.67
0.70
0.76
0.82
0.83
0.85
0.86
0.87
0.88
0.90
0.91
0.92

TC
5.72
5.83
6.55
8.17
9.60
9.96
10.50
10.61
10.85
11.08
11.29
11.45
11.55

86
PI
2.58
2.66
2.69
2.77
2.98
3.22
3.49
3.56
3.80
3.84
3.88
3.95
4.01
4.07
4.11

TC
20.04
20.92
21.58
22.02
24.30
26.96
30.00
30.76
33.42
33.75
34.52
35.25
35.92
36.42
36.76

PI
0.64
0.66
0.69
0.75
0.81
0.82
0.84
0.85
0.86
0.88
0.89
0.90
0.91

TC
5.58
5.70
6.40
7.97
9.38
9.73
10.25
10.36
10.59
10.82
11.02
11.18
11.28

PI
2.58
2.66
2.69
2.77
2.98
3.22
3.49
3.56
3.80
3.84
3.88
3.95
4.01
4.07
4.11

AS-W093F2B2(LAN090HVP/LAU090HVP)
Outdoor Air
Temperature
F DB
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
6.19
6.31
7.09
8.84
10.39
10.78
11.36
11.48
11.74
11.99
12.22
12.39
12.50

64
PI
0.66
0.68
0.71
0.78
0.83
0.85
0.87
0.88
0.88
0.90
0.91
0.93
0.94

TC
6.00
6.12
6.88
8.57
10.08
10.45
11.02
11.13
11.38
11.63
11.85
12.01
12.12

68
PI
0.66
0.68
0.70
0.77
0.82
0.84
0.86
0.87
0.88
0.89
0.91
0.92
0.93

TC
5.94
6.06
6.81
8.48
9.98
10.35
10.91
11.02
11.27
11.51
11.73
11.89
12.00

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

73

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
0.66
5.88
0.65
5.84
0.68
6.00
0.67
5.95
0.70
6.74
0.70
6.69
0.77
8.40
0.76
8.34
0.82
9.88
0.82
9.80
0.84
10.25 0.83
10.17
0.86
10.80 0.85
10.72
0.87
10.91 0.86
10.82
0.88
11.16 0.87
11.07
0.89
11.39 0.88
11.31
0.91
11.61 0.90
11.52
0.92
11.77 0.91
11.68
0.93
11.88 0.92
11.79

75

86
PI
0.64
0.66
0.69
0.75
0.81
0.82
0.84
0.85
0.86
0.88
0.89
0.90
0.91

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2. Direct interpolation is permissible. Do not extrapolate
3. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:70F(21.1C) DB / 60F(15.6C) WB
- Outdoor Air Temperature
: 47F(8.3C) DB / 43F(6.1C) WB

Inverter Single

6RMI0-06A

Capacity tables

AS-W123F2B2(LAN120HVP/LAU120HVP)
Outdoor Air
Temperature
F DB
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
8.87
9.05
9.81
11.52
13.04
13.42
14.00
14.14
14.46
14.76
15.04
15.25
15.39

64
PI
0.89
0.92
0.97
1.10
1.21
1.23
1.28
1.29
1.30
1.33
1.35
1.36
1.38

TC
8.60
8.77
9.51
11.17
12.65
13.02
13.57
13.71
14.02
14.32
14.59
14.79
14.93

68
PI
0.88
0.91
0.96
1.09
1.19
1.22
1.26
1.28
1.29
1.31
1.33
1.35
1.36

TC
8.51
8.69
9.42
11.06
12.52
12.89
13.43
13.57
13.88
14.17
14.44
14.64
14.78

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
0.88
8.43
0.87
8.36
0.91
8.60
0.90
8.53
0.96
9.32
0.95
9.25
1.09
10.95 1.08
10.87
1.19
12.40 1.18
12.30
1.22
12.76 1.21
12.66
1.26
13.30 1.25
13.20
1.28
13.43 1.26
13.33
1.29
13.74 1.28
13.63
1.31
14.03 1.30
13.92
1.33
14.30 1.32
14.19
1.35
14.50 1.34
14.39
1.36
14.63 1.35
14.52

75
PI
0.87
0.90
0.95
1.08
1.18
1.21
1.25
1.26
1.28
1.30
1.32
1.34
1.35

TC
8.20
8.36
9.07
10.65
12.05
12.41
12.93
13.06
13.36
13.64
13.90
14.10
14.23

PI
0.75
0.76
0.77
0.78
0.78
0.79
0.80
0.81
0.82
0.83
0.84

TC
5.79
7.00
8.08
8.35
8.75
8.84
9.04
9.23
9.41
9.54
9.63

86
PI
0.86
0.89
0.94
1.06
1.17
1.20
1.24
1.25
1.26
1.29
1.31
1.32
1.34

TC
8.00
8.16
8.85
10.39
11.77
12.11
12.63
12.75
13.04
13.32
13.57
13.76
13.89

PI
0.74
0.75
0.76
0.77
0.77
0.78
0.79
0.80
0.81
0.83
0.83

TC
5.65
6.84
7.89
8.15
8.54
8.63
8.83
9.01
9.18
9.31
9.40

PI
0.86
0.89
0.94
1.06
1.17
1.20
1.24
1.25
1.26
1.29
1.31
1.32
1.34

AS-W093WSA7 (LSN090HEV/LSU090HEV)
Outdoor Air
Temperature
F DB
24
32
41
43
47
53
59
64
70
75
78

F WB
23
30
38
40
43
50
55
60
66
71
75

60
TC
6.27
7.58
8.74
9.03
9.47
9.57
9.78
9.99
10.18
10.32
10.42

64
PI
0.76
0.78
0.79
0.79
0.80
0.80
0.81
0.83
0.84
0.85
0.86

TC
6.07
7.35
8.48
8.76
9.18
9.27
9.49
9.69
9.87
10.01
10.10

68
PI
0.75
0.77
0.78
0.78
0.79
0.80
0.80
0.82
0.83
0.84
0.85

TC
6.01
7.27
8.39
8.67
9.09
9.18
9.39
9.59
9.77
9.91
10.00

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
0.75
5.95
0.75
5.91
0.77
7.20
0.76
7.14
0.78
8.31
0.77
8.24
0.78
8.58
0.78
8.52
0.79
9.00
0.78
8.93
0.80
9.09
0.79
9.02
0.80
9.30
0.80
9.23
0.82
9.50
0.81
9.42
0.83
9.68
0.82
9.60
0.84
9.81
0.83
9.74
0.85
9.90
0.84
9.82

75

86
PI
0.74
0.75
0.76
0.77
0.77
0.78
0.79
0.80
0.81
0.83
0.83

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2. Direct interpolation is permissible. Do not extrapolate
3. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:70F(21.1C) DB / 60F(15.6C) WB
- Outdoor Air Temperature
: 47F(8.3C) DB / 43F(6.1C) WB

Inverter Single

74

Capacity tables

6RMI0-06A

AS-W123BSA7 (LSN120HEV/LSU120HEV)
Outdoor Air
Temperature
F DB
24
32
41
43
47
53
59
64
70
75
78

F WB
23
30
38
40
43
50
55
60
66
71
75

60
TC
8.26
10.05
11.64
12.03
12.63
12.75
13.04
13.32
13.57
13.76
13.89

64
PI
0.96
0.97
0.99
0.99
1.00
1.01
1.02
1.04
1.05
1.07
1.08

TC
8.01
9.74
11.28
11.67
12.24
12.37
12.65
12.92
13.16
13.35
13.47

PI
0.95
0.97
0.98
0.98
0.99
1.00
1.01
1.03
1.04
1.06
1.07

Indoor Air Temperature : DB


68
70
72
TC
PI
TC
PI
TC
7.93
0.95
7.85
0.94
7.79
9.65
0.97
9.55
0.96
9.48
11.17
0.98
11.06 0.97
10.97
11.55
0.98
11.43 0.97
11.35
12.12
0.99
12.00 0.98
11.91
12.24
1.00
12.12 0.99
12.03
12.52
1.01
12.40 1.00
12.30
12.79
1.03
12.66 1.02
12.56
13.03
1.04
12.90 1.03
12.80
13.21
1.06
13.08 1.05
12.98
13.33
1.07
13.20 1.06
13.10

75
PI
0.94
0.96
0.97
0.97
0.98
0.99
1.00
1.02
1.03
1.05
1.06

TC
7.64
9.29
10.75
11.12
11.67
11.79
12.05
12.31
12.54
12.72
12.84

86
PI
0.93
0.95
0.96
0.96
0.97
0.98
0.99
1.01
1.02
1.04
1.05

TC
7.46
9.07
10.50
10.86
11.39
11.51
11.77
12.02
12.25
12.42
12.53

PI
0.93
0.95
0.96
0.96
0.97
0.98
0.99
1.01
1.02
1.04
1.05

AS-W183CSA7 (LSN180HEV/LSU180HEV)
Outdoor Air
Temperature
F DB
24
32
41
43
47
53
59
64
70
75
78

F WB
23
30
38
40
43
50
55
60
66
71
75

60
TC
12.87
15.78
18.37
19.02
19.99
20.19
20.65
21.09
21.49
21.79
21.99

64
PI
1.55
1.58
1.61
1.61
1.62
1.64
1.65
1.69
1.71
1.74
1.75

TC
12.48
15.31
17.82
18.44
19.39
19.58
20.03
20.45
20.84
21.13
21.33

68
PI
1.54
1.57
1.59
1.60
1.61
1.62
1.64
1.67
1.69
1.72
1.73

TC
12.35
15.15
17.64
18.26
19.19
19.38
19.82
20.25
20.63
20.92
21.11

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

75

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
1.54
12.23 1.52
12.14
1.57
15.00 1.55
14.89
1.59
17.46 1.57
17.33
1.60
18.08 1.58
17.94
1.61
19.00 1.59
18.85
1.62
19.19 1.61
19.04
1.64
19.63 1.62
19.48
1.67
20.05 1.65
19.89
1.69
20.43 1.68
20.27
1.72
20.71 1.70
20.55
1.73
20.90 1.72
20.74

75
PI
1.52
1.55
1.57
1.58
1.59
1.61
1.62
1.65
1.68
1.70
1.72

TC
11.89
14.59
16.98
17.58
18.48
18.66
19.09
19.49
19.86
20.14
20.32

86
PI
1.51
1.53
1.56
1.57
1.57
1.59
1.61
1.64
1.66
1.68
1.70

TC
11.61
14.24
16.58
17.16
18.04
18.22
18.63
19.03
19.39
19.66
19.84

PI
1.51
1.53
1.56
1.57
1.57
1.59
1.61
1.64
1.66
1.68
1.70

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2. Direct interpolation is permissible. Do not extrapolate
3. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:70F(21.1C) DB / 60F(15.6C) WB
- Outdoor Air Temperature
: 47F(8.3C) DB / 43F(6.1C) WB

Inverter Single

6RMI0-06A

Capacity tables

AS-W243CSA7 (LSN240HEV/LSU240HEV)
Outdoor Air
Temperature
F DB
24
32
41
43
47
53
59
64
70
75
78

F WB
23
30
38
40
43
50
55
60
66
71
75

60
TC
15.14
18.41
21.33
22.06
23.15
23.38
23.91
24.42
24.89
25.23
25.46

64
PI
1.89
1.92
1.95
1.96
1.97
1.99
2.01
2.05
2.08
2.11
2.13

TC
14.68
17.86
20.68
21.39
22.45
22.67
23.19
23.68
24.13
24.47
24.69

PI
1.87
1.91
1.94
1.94
1.95
1.97
1.99
2.03
2.06
2.09
2.11

Indoor Air Temperature : DB


68
70
72
TC
PI
TC
PI
TC
14.53
1.87
14.38 1.85
14.27
17.68
1.91
17.50 1.89
17.37
20.47
1.94
20.27 1.92
20.11
21.17
1.94
20.96 1.92
20.80
22.22
1.95
22.00 1.94
21.83
22.44
1.97
22.22 1.95
22.05
22.95
1.99
22.73 1.97
22.55
23.44
2.03
23.21 2.01
23.03
23.89
2.06
23.65 2.04
23.47
24.22
2.09
23.98 2.07
23.80
24.44
2.11
24.20 2.09
24.02

75
PI
1.85
1.89
1.92
1.92
1.94
1.95
1.97
2.01
2.04
2.07
2.09

TC
13.99
17.02
19.71
20.38
21.39
21.61
22.10
22.57
23.00
23.32
23.53

PI
0.47
0.54
0.60
0.62
0.64
0.65
0.67
0.67
0.69
0.69
0.70
0.70
0.71
0.71
0.73
0.74
0.75
0.76

TC
4.69
5.45
5.94
6.28
6.56
6.77
6.90
7.49
8.80
9.97
10.26
10.70
10.80
11.05
11.29
11.50
11.66
11.77

86
PI
1.83
1.87
1.90
1.90
1.92
1.93
1.95
1.99
2.02
2.05
2.07

TC
13.66
16.61
19.24
19.90
20.88
21.09
21.57
22.03
22.45
22.76
22.97

PI
0.46
0.54
0.59
0.62
0.64
0.64
0.66
0.67
0.68
0.69
0.69
0.69
0.70
0.71
0.72
0.73
0.74
0.75

TC
4.58
5.32
5.80
6.13
6.40
6.61
6.74
7.31
8.59
9.73
10.02
10.44
10.55
10.79
11.02
11.23
11.38
11.49

PI
1.83
1.87
1.90
1.90
1.92
1.93
1.95
1.99
2.02
2.05
2.07

AS-W093MMB8 (LAN090HYV/LAU090HYV)
Outdoor Air
Temperature
F DB
-12
-3
0
6
10
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
-13
-4
-1
5
9
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
5.08
5.90
6.43
6.80
7.10
7.32
7.47
8.10
9.52
10.79
11.10
11.57
11.69
11.96
12.21
12.44
12.62
12.73

64
PI
0.48
0.55
0.61
0.64
0.66
0.66
0.68
0.69
0.70
0.71
0.71
0.71
0.72
0.73
0.74
0.75
0.76
0.77

TC
4.93
5.72
6.23
6.59
6.88
7.10
7.24
7.86
9.23
10.46
10.76
11.22
11.34
11.59
11.84
12.07
12.23
12.35

PI
0.47
0.55
0.60
0.63
0.65
0.66
0.68
0.68
0.69
0.70
0.70
0.71
0.71
0.72
0.74
0.75
0.76
0.76

Indoor Air Temperature : DB


68
70
72
TC
PI
TC
PI
TC
4.88
0.47
4.83
0.47
4.79
5.67
0.55
5.61
0.54
5.57
6.17
0.60
6.11
0.60
6.06
6.53
0.63
6.46
0.62
6.41
6.81
0.65
6.75
0.64
6.69
7.03
0.66
6.96
0.65
6.90
7.17
0.68
7.10
0.67
7.05
7.78
0.68
7.70
0.67
7.64
9.14
0.69
9.05
0.69
8.98
10.35
0.70
10.25 0.69
10.17
10.66
0.70
10.55 0.70
10.47
11.11
0.71
11.00 0.70
10.92
11.22
0.71
11.11 0.71
11.03
11.48
0.72
11.36 0.71
11.28
11.72
0.74
11.61 0.73
11.52
11.94
0.75
11.83 0.74
11.73
12.11
0.76
11.99 0.75
11.90
12.22
0.76
12.10 0.76
12.01

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

75

86
PI
0.46
0.54
0.59
0.62
0.64
0.64
0.66
0.67
0.68
0.69
0.69
0.69
0.70
0.71
0.72
0.73
0.74
0.75

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2. Direct interpolation is permissible. Do not extrapolate
3. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:70F(21.1C) DB / 60F(15.6C) WB
- Outdoor Air Temperature
: 47F(8.3C) DB / 43F(6.1C) WB

Inverter Single

76

Capacity tables

6RMI0-06A

AS-W123MMB8(LAN120HYV/LAU120HYV)
Outdoor Air
Temperature
F DB
-12
-3
0
6
10
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
-13
-4
-1
5
9
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
6.01
6.98
7.60
8.04
8.40
8.66
8.84
9.68
11.57
13.26
13.68
14.31
14.45
14.78
15.10
15.38
15.60
15.74

64
PI
0.59
0.68
0.74
0.78
0.80
0.81
0.84
0.84
0.86
0.87
0.87
0.88
0.89
0.89
0.91
0.93
0.94
0.95

TC
5.83
6.77
7.37
7.80
8.14
8.40
8.57
9.39
11.22
12.86
13.26
13.88
14.02
14.33
14.64
14.92
15.13
15.26

68
PI
0.58
0.67
0.74
0.77
0.80
0.80
0.83
0.83
0.85
0.86
0.86
0.87
0.88
0.89
0.90
0.92
0.93
0.94

TC
5.77
6.70
7.30
7.72
8.06
8.31
8.48
9.29
11.11
12.73
13.13
13.74
13.87
14.19
14.49
14.77
14.97
15.11

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
0.58
5.71
0.57
5.67
0.67
6.64
0.66
6.59
0.74
7.22
0.73
7.17
0.77
7.64
0.76
7.59
0.80
7.98
0.79
7.92
0.80
8.23
0.80
8.17
0.83
8.40
0.82
8.34
0.83
9.20
0.83
9.13
0.85
11.00 0.84
10.92
0.86
12.60 0.85
12.50
0.86
13.00 0.86
12.90
0.87
13.60 0.86
13.50
0.88
13.74 0.87
13.63
0.89
14.05 0.88
13.94
0.90
14.35 0.89
14.24
0.92
14.62 0.91
14.51
0.93
14.82 0.92
14.71
0.94
14.96 0.93
14.85

75
PI
0.57
0.66
0.73
0.76
0.79
0.80
0.82
0.83
0.84
0.85
0.86
0.86
0.87
0.88
0.89
0.91
0.92
0.93

TC
5.55
6.45
7.02
7.43
7.76
8.01
8.17
8.95
10.70
12.25
12.64
13.23
13.36
13.66
13.95
14.22
14.42
14.55

PI
0.49
0.54
0.57
0.59
0.59
0.61
0.62
0.66
0.68
0.69
0.70
0.71
0.71
0.73
0.74
0.75
0.76

TC
5.07
5.52
5.84
6.10
6.29
6.42
7.05
8.46
9.72
10.03
10.50
10.61
10.85
11.08
11.29
11.45
11.55

86
PI
0.57
0.66
0.72
0.75
0.78
0.79
0.81
0.82
0.83
0.84
0.85
0.85
0.86
0.87
0.89
0.90
0.91
0.92

TC
5.42
6.30
6.86
7.26
7.58
7.81
7.97
8.73
10.44
11.96
12.34
12.91
13.04
13.34
13.62
13.88
14.07
14.20

PI
0.49
0.54
0.56
0.58
0.59
0.60
0.62
0.65
0.68
0.68
0.69
0.70
0.71
0.72
0.73
0.74
0.75

TC
4.95
5.39
5.70
5.95
6.14
6.27
6.88
8.26
9.49
9.79
10.25
10.36
10.59
10.82
11.02
11.18
11.28

PI
0.57
0.66
0.72
0.75
0.78
0.79
0.81
0.82
0.83
0.84
0.85
0.85
0.86
0.87
0.89
0.90
0.91
0.92

AS-W093B1B8 (LSN091HSV3/LSU091HSV3)
Outdoor Air
Temperature
F DB
-3
0
6
10
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
-4
-1
5
9
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
5.49
5.97
6.32
6.60
6.81
6.94
7.62
9.15
10.51
10.85
11.36
11.48
11.74
11.99
12.22
12.39
12.50

64
PI
0.50
0.55
0.58
0.60
0.60
0.62
0.64
0.67
0.70
0.70
0.71
0.72
0.73
0.74
0.75
0.76
0.77

TC
5.32
5.79
6.13
6.40
6.60
6.73
7.39
8.88
10.20
10.53
11.02
11.13
11.38
11.63
11.85
12.01
12.12

PI
0.50
0.55
0.57
0.59
0.60
0.62
0.63
0.66
0.69
0.70
0.71
0.71
0.72
0.74
0.75
0.76
0.76

Indoor Air Temperature : DB


68
70
72
TC
PI
TC
PI
TC
5.27
0.50
5.21
0.49
5.17
5.73
0.55
5.68
0.54
5.63
6.07
0.57
6.01
0.57
5.96
6.33
0.59
6.27
0.59
6.22
6.53
0.60
6.47
0.59
6.42
6.67
0.62
6.60
0.61
6.55
7.32
0.63
7.25
0.62
7.19
8.79
0.66
8.70
0.66
8.63
10.09
0.69
9.99
0.68
9.92
10.42
0.70
10.32 0.69
10.24
10.91
0.71
10.80 0.70
10.72
11.02
0.71
10.91 0.71
10.82
11.27
0.72
11.16 0.71
11.07
11.51
0.74
11.39 0.73
11.31
11.73
0.75
11.61 0.74
11.52
11.89
0.76
11.77 0.75
11.68
12.00
0.76
11.88 0.76
11.79

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

77

75

86
PI
0.49
0.54
0.56
0.58
0.59
0.60
0.62
0.65
0.68
0.68
0.69
0.70
0.71
0.72
0.73
0.74
0.75

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2. Direct interpolation is permissible. Do not extrapolate
3. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:70F(21.1C) DB / 60F(15.6C) WB
- Outdoor Air Temperature
: 47F(8.3C) DB / 43F(6.1C) WB

Inverter Single

6RMI0-06A

Capacity tables

AS-W123B1B8 (LSN121HSV3/LSU121HSV3)
Outdoor Air
Temperature
F DB
-3
0
6
10
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
-4
-1
5
9
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
7.23
7.87
8.33
8.70
8.97
9.15
9.90
11.57
13.06
13.44
14.00
14.14
14.46
14.76
15.04
15.25
15.39

64
PI
0.70
0.77
0.81
0.83
0.84
0.87
0.89
0.94
0.99
1.00
1.02
1.03
1.04
1.06
1.08
1.09
1.10

TC
7.01
7.63
8.08
8.43
8.70
8.88
9.60
11.22
12.67
13.03
13.57
13.71
14.02
14.32
14.59
14.79
14.93

68
PI
0.70
0.76
0.80
0.82
0.83
0.86
0.88
0.93
0.98
0.99
1.01
1.02
1.03
1.05
1.07
1.08
1.09

TC
6.94
7.56
8.00
8.35
8.61
8.79
9.50
11.11
12.54
12.90
13.43
13.57
13.88
14.17
14.44
14.64
14.78

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
0.70
6.87
0.69
6.82
0.76
7.48
0.76
7.42
0.80
7.92
0.79
7.86
0.82
8.27
0.82
8.20
0.83
8.53
0.82
8.46
0.86
8.70
0.85
8.63
0.88
9.41
0.87
9.34
0.93
11.00 0.93
10.92
0.98
12.42 0.97
12.32
0.99
12.77 0.98
12.67
1.01
13.30 1.00
13.20
1.02
13.43 1.01
13.33
1.03
13.74 1.02
13.63
1.05
14.03 1.04
13.92
1.07
14.30 1.06
14.19
1.08
14.50 1.07
14.39
1.09
14.63 1.08
14.52

75
PI
0.69
0.76
0.79
0.82
0.82
0.85
0.87
0.93
0.97
0.98
1.00
1.01
1.02
1.04
1.06
1.07
1.08

TC
6.68
7.28
7.70
8.04
8.29
8.46
9.15
10.70
12.07
12.42
12.93
13.06
13.36
13.64
13.90
14.10
14.23

PI
1.15
1.26
1.32
1.36
1.38
1.42
1.47
1.59
1.69
1.72
1.76
1.78
1.80
1.83
1.86
1.88
1.90

TC
10.37
11.29
11.95
12.47
12.87
13.13
14.40
17.26
19.80
20.44
21.39
21.61
22.10
22.57
23.00
23.32
23.53

86
PI
0.68
0.75
0.78
0.81
0.82
0.84
0.86
0.92
0.96
0.97
0.99
1.00
1.01
1.03
1.04
1.06
1.07

TC
6.52
7.10
7.52
7.85
8.09
8.26
8.93
10.44
11.79
12.12
12.63
12.75
13.04
13.32
13.57
13.76
13.89

PI
1.14
1.25
1.31
1.35
1.36
1.41
1.46
1.57
1.68
1.70
1.74
1.76
1.78
1.81
1.84
1.86
1.88

TC
10.12
11.02
11.66
12.17
12.56
12.82
14.06
16.85
19.33
19.95
20.88
21.09
21.57
22.03
22.45
22.76
22.97

PI
0.68
0.75
0.78
0.81
0.82
0.84
0.86
0.92
0.96
0.97
0.99
1.00
1.01
1.03
1.04
1.06
1.07

AS-W183C2B8 (LSN181HSV3/LSU181HSV3)
Outdoor Air
Temperature
F DB
-3
0
6
10
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
-4
-1
5
9
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
11.22
12.22
12.93
13.50
13.92
14.21
15.58
18.68
21.43
22.12
23.15
23.38
23.91
24.42
24.89
25.23
25.46

64
PI
1.17
1.29
1.35
1.39
1.40
1.45
1.50
1.62
1.73
1.76
1.80
1.81
1.83
1.87
1.89
1.92
1.94

TC
10.88
11.85
12.53
13.09
13.50
13.77
15.11
18.11
20.78
21.45
22.45
22.67
23.19
23.68
24.13
24.47
24.69

68
PI
1.16
1.28
1.33
1.38
1.39
1.43
1.49
1.61
1.71
1.74
1.78
1.80
1.81
1.85
1.88
1.90
1.92

TC
10.77
11.73
12.41
12.95
13.36
13.64
14.96
17.93
20.57
21.23
22.22
22.44
22.95
23.44
23.89
24.22
24.44

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
1.16
10.67 1.15
10.58
1.28
11.61 1.26
11.52
1.33
12.29 1.32
12.19
1.38
12.83 1.36
12.73
1.39
13.23 1.38
13.13
1.43
13.50 1.42
13.40
1.49
14.81 1.47
14.69
1.61
17.75 1.59
17.61
1.71
20.37 1.69
20.21
1.74
21.02 1.72
20.86
1.78
22.00 1.76
21.83
1.80
22.22 1.78
22.05
1.81
22.73 1.80
22.55
1.85
23.21 1.83
23.03
1.88
23.65 1.86
23.47
1.90
23.98 1.88
23.80
1.92
24.20 1.90
24.02

75

86
PI
1.14
1.25
1.31
1.35
1.36
1.41
1.46
1.57
1.68
1.70
1.74
1.76
1.78
1.81
1.84
1.86
1.88

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2. Direct interpolation is permissible. Do not extrapolate
3. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:70F(21.1C) DB / 60F(15.6C) WB
- Outdoor Air Temperature
: 47F(8.3C) DB / 43F(6.1C) WB

Inverter Single

78

Capacity tables

6RMI0-06A

AS-W243D8B8 (LSN240HSV3/LSU240HSV3)
Outdoor Air
Temperature
F DB
-3
0
6
10
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
-4
-1
5
9
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
15.55
16.92
17.91
18.69
19.28
19.68
21.12
24.36
27.24
27.96
29.04
29.33
30.00
30.64
31.22
31.66
31.95

64
PI
1.63
1.79
1.87
1.93
1.95
2.01
2.07
2.22
2.35
2.38
2.43
2.45
2.48
2.52
2.56
2.60
2.62

TC
15.07
16.41
17.36
18.13
18.70
19.08
20.48
23.62
26.41
27.11
28.16
28.44
29.09
29.71
30.27
30.70
30.98

68
PI
1.61
1.77
1.85
1.91
1.93
1.99
2.05
2.20
2.32
2.36
2.40
2.43
2.45
2.50
2.54
2.57
2.60

TC
14.92
16.24
17.19
17.94
18.51
18.89
20.27
23.38
26.15
26.84
27.88
28.15
28.80
29.41
29.97
30.38
30.66

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
1.61
14.77 1.60
14.66
1.77
16.08 1.75
15.96
1.85
17.02 1.83
16.89
1.91
17.77 1.89
17.63
1.93
18.33 1.91
18.19
1.99
18.70 1.97
18.56
2.05
20.07 2.03
19.92
2.20
23.15 2.18
22.97
2.32
25.89 2.30
25.69
2.36
26.57 2.33
26.37
2.40
27.60 2.38
27.39
2.43
27.88 2.40
27.66
2.45
28.51 2.43
28.29
2.50
29.12 2.48
28.90
2.54
29.67 2.51
29.44
2.57
30.08 2.55
29.85
2.60
30.36 2.57
30.13

75
PI
1.60
1.75
1.83
1.89
1.91
1.97
2.03
2.18
2.30
2.33
2.38
2.40
2.43
2.48
2.51
2.55
2.57

TC
14.37
15.64
16.55
17.28
17.82
18.18
19.52
22.51
25.17
25.84
26.84
27.11
27.72
28.32
28.85
29.25
29.52

PI
2.00
2.20
2.30
2.37
2.40
2.47
2.57
2.79
2.98
3.03
3.10
3.13
3.16
3.22
3.27
3.32
3.35

TC
17.21
18.73
19.82
20.69
21.35
21.78
23.22
26.45
29.32
30.04
31.12
31.43
32.14
32.83
33.45
33.92
34.23

86
PI
1.58
1.74
1.81
1.87
1.89
1.95
2.01
2.15
2.28
2.31
2.36
2.38
2.40
2.45
2.49
2.52
2.54

TC
14.02
15.27
16.15
16.86
17.40
17.75
19.05
21.98
24.58
25.23
26.20
26.46
27.07
27.64
28.17
28.56
28.82

PI
1.98
2.18
2.27
2.35
2.37
2.45
2.54
2.76
2.95
3.00
3.07
3.10
3.13
3.19
3.24
3.28
3.31

TC
16.80
18.29
19.35
20.20
20.84
21.26
22.67
25.82
28.63
29.33
30.38
30.68
31.38
32.05
32.66
33.11
33.42

PI
1.58
1.74
1.81
1.87
1.89
1.95
2.01
2.15
2.28
2.31
2.36
2.38
2.40
2.45
2.49
2.52
2.54

AS-W303D8B8 (LSN307HV3/LSU307HV3)
Outdoor Air
Temperature
F DB
-3
0
6
10
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
-4
-1
5
9
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
18.62
20.27
21.45
22.39
23.10
23.57
25.12
28.62
31.73
32.51
33.67
34.01
34.78
35.52
36.20
36.70
37.04

64
PI
2.04
2.24
2.34
2.42
2.44
2.52
2.62
2.84
3.04
3.09
3.16
3.19
3.23
3.29
3.34
3.38
3.41

TC
18.06
19.66
20.80
21.71
22.40
22.86
24.36
27.75
30.77
31.52
32.65
32.98
33.73
34.45
35.10
35.59
35.92

68
PI
2.02
2.22
2.32
2.39
2.42
2.49
2.59
2.81
3.01
3.06
3.13
3.16
3.19
3.26
3.30
3.35
3.38

TC
17.87
19.46
20.59
21.49
22.17
22.62
24.12
27.47
30.46
31.20
32.32
32.64
33.39
34.10
34.74
35.23
35.55

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

79

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
2.02
17.70 2.00
17.56
2.22
19.26 2.20
19.12
2.32
20.38 2.30
20.23
2.39
21.28 2.37
21.12
2.42
21.95 2.40
21.78
2.49
22.40 2.47
22.23
2.59
23.88 2.57
23.69
2.81
27.20 2.79
26.99
3.01
30.15 2.98
29.92
3.06
30.89 3.03
30.66
3.13
32.00 3.10
31.76
3.16
32.32 3.13
32.07
3.19
33.06 3.16
32.80
3.26
33.76 3.22
33.50
3.30
34.40 3.27
34.14
3.35
34.88 3.32
34.61
3.38
35.20 3.35
34.93

75

86
PI
1.98
2.18
2.27
2.35
2.37
2.45
2.54
2.76
2.95
3.00
3.07
3.10
3.13
3.19
3.24
3.28
3.31

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2. Direct interpolation is permissible. Do not extrapolate
3. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:70F(21.1C) DB / 60F(15.6C) WB
- Outdoor Air Temperature
: 47F(8.3C) DB / 43F(6.1C) WB

Inverter Single

6RMI0-06A

Capacity tables

AS-W363D8B8 (LSN360HV3/LSU360HV3)
Outdoor Air
Temperature
F DB
-3
0
6
10
16
19
24
32
41
43
47
53
59
64
70
75
78

F WB
-4
-1
5
9
14
17
23
30
38
40
43
50
55
60
66
71
75

60
TC
20.28
22.08
23.36
24.39
25.16
25.68
27.42
31.36
34.85
35.73
37.04
37.41
38.26
39.08
39.82
40.37
40.74

64
PI
2.35
2.58
2.69
2.78
2.81
2.90
3.05
3.41
3.72
3.80
3.92
3.96
4.00
4.07
4.13
4.19
4.23

TC
19.67
21.41
22.66
23.65
24.40
24.90
26.59
30.41
33.80
34.64
35.92
36.28
37.10
37.89
38.61
39.15
39.51

68
PI
2.32
2.55
2.67
2.75
2.78
2.87
3.02
3.37
3.68
3.76
3.88
3.92
3.96
4.03
4.09
4.15
4.19

TC
19.47
21.19
22.43
23.41
24.15
24.64
26.32
30.10
33.45
34.29
35.55
35.91
36.73
37.51
38.22
38.75
39.11

Symbol
DB : Dry Bulb Temperature
[(F)]
WB : Wet Bulb Temperature
[(F)]
TC : Total Capacity
[kBtu/h]
PI : Power Input
[kW]
(Comp.+ indoor fan motor + outdoor fan motor)

Indoor Air Temperature : DB


70
72
PI
TC
PI
TC
2.32
19.28 2.30
19.13
2.55
20.98 2.53
20.82
2.67
22.20 2.64
22.03
2.75
23.18 2.73
23.00
2.78
23.91 2.75
23.73
2.87
24.40 2.84
24.21
3.02
26.06 2.99
25.86
3.37
29.80 3.34
29.57
3.68
33.12 3.65
32.87
3.76
33.95 3.72
33.69
3.88
35.20 3.84
34.93
3.92
35.55 3.88
35.28
3.96
36.36 3.92
36.08
4.03
37.14 3.99
36.85
4.09
37.84 4.05
37.55
4.15
38.37 4.11
38.07
4.19
38.72 4.15
38.42

75
PI
2.30
2.53
2.64
2.73
2.75
2.84
2.99
3.34
3.65
3.72
3.84
3.88
3.92
3.99
4.05
4.11
4.15

TC
18.74
20.41
21.59
22.54
23.25
23.73
25.34
28.98
32.21
33.02
34.23
34.57
35.36
36.11
36.80
37.31
37.65

86
PI
2.28
2.50
2.61
2.70
2.73
2.81
2.96
3.31
3.61
3.69
3.80
3.84
3.88
3.95
4.01
4.07
4.11

TC
18.30
19.92
21.08
22.01
22.70
23.16
24.74
28.29
31.44
32.23
33.42
33.75
34.52
35.25
35.92
36.42
36.76

PI
2.28
2.50
2.61
2.70
2.73
2.81
2.96
3.31
3.61
3.69
3.80
3.84
3.88
3.95
4.01
4.07
4.11

Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2. Direct interpolation is permissible. Do not extrapolate
3. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
- Indoor Air Temperature
:70F(21.1C) DB / 60F(15.6C) WB
- Outdoor Air Temperature
: 47F(8.3C) DB / 43F(6.1C) WB

Inverter Single

80

Capacity coefficient factor

6RMI0-06A

8. Capacity coefficient factor


Cooling

Capacity(%)

100

95

90
9k,12k

7.5(24.6)

20(65.6)

30(98.4)

Total Pipe Length[m(ft)]

Capacity(%)

Heating
100

95
9k,12k

7.5(24.6)

20(65.6)

Total Pipe Length[m(ft)]

Applied Model
: LS091HSV2 / LS121HSV2 / LA090HSV2 / LA120HSV2
LA090HYV / LA120HYV / LS091HSV3 / LS121HSV3

81

Inverter Single

30(98.4)

6RMI0-06A

Capacity coefficient factor

Cooling

Capacity(%)

100

95
24k,30k,36k
18k

90

7.5(24.6)

20(65.6)

30(98.4)

Total Pipe Length[m(ft)]

Capacity(%)

Heating
100

24k,30k,36k

95
18k

7.5(24.6)

20(65.6)

30(98.4)

Total Pipe Length[m(ft)]

Applied Model
: LS181HSV2 / LA180HSV2 / LA240HSV2 / LS240HSV2 / LS307HV2 / LS360HV2
LS181HSV3 / LS240HSV3 / LS307HV3 / LS360HV3

Inverter Single

82

Capacity coefficient factor

6RMI0-06A

Cooling

Capacity(%)

110

105

100

95

90

3(9.84)

7.5(24.6)

15(49.2)

Total Pipe Length[m(ft)]

Heating

Capacity(%)

110

105

100

95

90

3(9.84)

7.5(24.6)

Total Pipe Length[m(ft)]


Applied Model
: LS090HYV / LS120HYV / LA090HVP / LA120HVP

83

Inverter Single

15(49.2)

6RMI0-06A

Capacity coefficient factor

Cooling

Capacity(%)

100

18k,24k
9k,12k
90

7.5(24.6)

15(49.2)

20(65.6)

Total Pipe Length[m(ft)]

Capacity(%)

Heating
100

95

7.5(24.6)

18k,24k

9k,12k

15(49.2)

20(65.6)

Total Pipe Length[m(ft)]

Applied Model
: LS090HEV / LS120HEV / LS180HEV / LS240HEV

Inverter Single

84

Capacity coefficient factor

6RMI0-06A

Max. Pipe Length


[m(ft)]
20(65.6)
20(65.6)
20(65.6)
15(49.2)
20(65.6)
15(49.2)
15(49.2)
20(65.6)
20(65.6)
20(65.6)
15(49.2)
15(49.2)
20(65.6)
15(49.2)
30(98.4)
30(98.4)
30(98.4)
20(65.6)
30(98.4)
20(65.6)
30(98.4)
30(98.4)
30(98.4)
30(98.4)
30(98.4)
30(98.4)

Models
ASUW093B1B8 [LSU091HSV3]
ASUW093B1Y9 [LSU091HSV2]
ASUW093BRM9 [LAU090HSV2]
ASUW093FUB2 [LAU090HVP]
ASUW093MMB8 [LAU090HYV]
ASUW093MMM9 [LSU090HYV]
ASUW093WSA7 [LSU090HEV]
ASUW123B1B8 [LSU121HSV3]
ASUW123B1Y9 [LSU121HSV2]
ASUW123BRM9 [LAU120HSV2]
ASUW123BSA7 [LSU120HEV]
ASUW123FUB2 [LAU120HVP]
ASUW123MMB8 [LAU120HYV]
ASUW123MMM9 [LSU120HYV]
ASUW183C2B8 [LSU181HSV3]
ASUW183C2Y9 [LSU181HSV2]
ASUW183CRM9 [LAU180HSV2]
ASUW183CSA7 [LSU180HEV]
ASUW243CRM9 [LAU240HSV2]
ASUW243CSA7 [LSU240HEV]
ASUW243D8B8 [LSU240HSV3]
ASUW243DGY9 [LSU240HSV2]
ASUW303D8B8 [LSU307HV3]
ASUW303DGY9 [LSU307HV2]
ASUW363D8B8 [LSU360HV3]
ASUW363DGY9 [LSU360HV2]

Max. Elevation
[m(ft)]
10(32.8)
10(32.8)
10(32.8)
7(22.9)
10(32.8)
7(22.9)
7(22.9)
10(32.8)
10(32.8)
10(32.8)
7(22.9)
7(22.9)
10(32.8)
7(22.9)
15(49.2)
15(49.2)
15(49.2)
10(32.8)
15(49.2)
10(32.8)
15(49.2)
15(49.2)
15(49.2)
15(49.2)
15(49.2)
15(49.2)

Indoor unit

Outdoor unit

A
B

Additional Refrigerant
[g/m(oz/ft)
20(0.22)
20(0.22)
20(0.22)
20(0.22)
20(0.22)
20(0.22)
20(0.22)
20(0.22)
20(0.22)
20(0.22)
20(0.22)
20(0.22)
20(0.22)
20(0.22)
35(0.38)
35(0.38)
35(0.38)
30(0.33)
35(0.38)
30(0.33)
35(0.38)
35(0.38)
35(0.38)
35(0.38)
35(0.38)
35(0.38)

A
Outdoor unit

Indoor unit

CAUTION:
Capacity is based on standard length and maximum allowance length is on the basis of reliability.

Notes
h Equivalent pipe length = actual pipe length + number of bends x 0.3
h Additional Refrigerant Charge
Example : For LS121HSV2 having 20m(65.6ft) pipe length, additional refrigerant to be charged is
(20m(65.6ft))-12.5m(41.0ft) x 20g/m( 0.22 oz/ft) =150g(5.41oz)
* Refer to the specification for the maximum pipe length of each model.
* Specially LS091HSV2 / LS121HSV2 / LA090HSV2 / LA120HSV2 / LS091HSV3 / LS121HSV3 / LA090HYV / LA120HYV
Additional refrigerant must be charged after 12.5m(41ft) (there is no need to charge till 12.5m(41ft) based on reliability)

85

Inverter Single

6RMI0-06A

Electric characteristics

9. Electric characteristics
Unit
Model
ASUW093B1B8 [LSU091HSV3]
ASUW093B1Y9 [LSU091HSV2]
ASUW093BRM9 [LAU090HSV2]
ASUW093FUB2 [LAU090HVP]
ASUW093MMB8 [LAU090HYV]
ASUW093MMM9 [LSU090HYV]
ASUW093WSA7 [LSU090HEV]
ASUW123B1B8 [LSU121HSV3]
ASUW123B1Y9 [LSU121HSV2]
ASUW123BRM9 [LAU120HSV2]
ASUW123BSA7 [LSU120HEV]
ASUW123FUB2 [LAU120HVP]
ASUW123MMB8 [LAU120HYV]
ASUW123MMM9 [LSU120HYV]
ASUW183C2B8 [LSU181HSV3]
ASUW183C2Y9 [LSU181HSV2]
ASUW183CRM9 [LAU180HSV2]
ASUW183CSA7 [LSU180HEV]
ASUW243CRM9 [LAU240HSV2]
ASUW243CSA7 [LSU240HEV]
ASUW243D8B8 [LSU240HSV3]
ASUW243DGY9 [LSU240HSV2]
ASUW303D8B8 [LSU307HV3]
ASUW303DGY9 [LSU307HV2]
ASUW363D8B8 [LSU360HV3]
ASUW363DGY9 [LSU360HV2]

Type

Inverter

Power
Hz

60

Voltage

Voltage range MCA

208~230

10
10
10
10
11.2
10
9
10
10
10
9
10
11.2
10
19
19
19
12
19
14
19
19
19
19
19
19

Notes :
1. Voltage range
Voltage supplied to the unit terminals should be within
the minimum and maximum range.
2. Maximum allowable voltage unbalance between phase
is 2 %.
3. Select wire spec. based on the larger value of MCA.
4. RLA is measured during each individual compressor test
condition.
5. OFM is measured as the outdoor unit test condition
6. Recommended circuit breaker is ELCB (Earth Leakage
circuit breaker)

MIN : 187
MAX : 253

Compressor

OFM

MOP

MSC

RLA

kW

FLA

15
15
15
15
15
15
15
15
15
15
15
15
15
15
25
30
30
20
30
20
25
30
25
30
25
30

8.3
7.6
7.6
7.6
8.3
7.6
6.8
8.3
7.6
7.6
6.8
7.6
8.3
7.6
14.6
14.6
14.6
9.28
14.6
10.8
14.6
14.6
14.6
14.6
14.6
14.6

0.08
0.08
0.08
0.08
0.12
0.12
0.075
0.08
0.08
0.08
0.075
0.08
0.12
0.12
0.12
0.12
0.12
0.04
0.12
0.08
0.12
0.12
0.12
0.12
0.12
0.12

0.40
0.25
0.45
0.25
0.40
1.04
0.50
0.40
0.25
0.45
0.50
0.25
0.40
1.04
0.25
0.25
0.75
0.40
0.75
0.48
0.25
0.75
0.25
0.75
0.25
0.75

MCA : Minimum Circuit Amperes (A)


MOP : Maximum rating over current protective device.(A)
MSC : Maximum Starting Current)(A)
RLA : Rated Load Amperes (A)
OFM : Outdoor Fan Motor
kW : Fan Motor rated output (kW)
FLA : Full Load Amperes (A)

Inverter Single

86

Operation range

6RMI0-06A

10. Operation range


Heating

Cooling
48(118F)

Continuous
operation

24(75F)
Outdoor
Unit
[C WB]

Warming up
Operation

Outdoor
Unit
[C DB]

Continuous
operation

-10(14F)
-10(14F)
18(64F)

32(90F)

16(60F)

30(86F)

Indoor Unit [C WB]

Indoor Unit [C DB]


Operative: Intermittent operation due to the operational conditions (indoor/outdoor
temperature, humidity, load etc.) can cause the heating capacity to decrease.
* Applied Model : LS090HYV, LS120HYV, LA090HVP, LA120HVP

Cooling

Heating

48(118F)

24(75F)

Continuous
operation

Outdoor
Unit
[C WB]

-10(14)

Warming up
Operation

Outdoor
Unit
[C DB]

Continuous
operation

-15(5F)
18(64F)

32(90F)

Indoor Unit [C WB]

16(60F)

30(86F)

Indoor Unit [C DB]

Operative: Intermittent operation due to the operational conditions (indoor/outdoor


temperature, humidity, load etc.) can cause the heating capacity to decrease.
* With wind baffle accessory installed. With wind baffle installed, the
minimum temperature will be below 14 D.B.
* Applied Model : LS091HSV2, LS121HSV2, LS181HSV2, LS240HSV2, LS307HV2, LS360HV2

87

Inverter Single

6RMI0-06A

Operation range

Cooling

Heating

48(118F)

24(75F)

Continuous
operation

Outdoor
Unit
[C WB]

-10(14F)

Warming up
Operation

Outdoor
Unit
[C DB]

Continuous
operation

-15(5F)
18(64F)

32(90F)

16(60F)

30(86F)

Indoor Unit [C WB]

Indoor Unit [C DB]


Operative: Intermittent operation due to the operational conditions (indoor/outdoor
temperature, humidity, load etc.) can cause the heating capacity to decrease.
* Applied Model : LA090HSV2 , LA120HSV2 , LA180HSV2 , LA240HSV2

Heating

Cooling
48(118F)

Continuous
operation

Outdoor
Unit
[C DB]

Outdoor
Unit
[C WB]

Warming up
Operation

24(75F)
18(64F)

Continuous
operation

-5(23)

18(64F)

32(90F)

Indoor Unit [C WB]

16(60F)

30(86F)

Indoor Unit [C DB]

* Applied Model : LS090HEV,LS120HEV,LS180HEV,LS240HEV

Inverter Single

88

Operation range

6RMI0-06A

Cooling

Heating

48(118F)

24(75F)

Continuous
operation

Outdoor
Unit
[C WB]

-10(14)

Warming up
Operation

Outdoor
Unit
[C DB]

Continuous
operation

-20(-4F)
18(64F)

32(90F)

16(60F)

Indoor Unit [C WB]

30(86F)

Indoor Unit [C DB]

* Applied Model : LS091HSV3, LS121HSV3, LS181HSV3, LS240HSV3,


LS307HV3, LS360HV3

Cooling

Heating

48(118F)

24(75F)

Continuous
operation

Outdoor
Unit
[C WB]

Warming up
Operation

Outdoor
Unit
[C DB]

Continuous
operation

-25(-13F)
-10(14)
18(64F)

32(90F)

Indoor Unit [C WB]

* Applied Model : LA090HYV, LA120HYV

89

Inverter Single

16(60F)
Indoor Unit [C DB]

30(86F)

6RMI0-06A

Air flow and temperature distributions (reference data)

11. Air flow and temperature distributions (reference data)


2.64 kW (9kBtu/h) LAN090HSV2 / LSN091HSV2 / LSN090HEV / LSN091HSV3 / LAN090HYV
Cooling

Heating

Discharge angle:45

Discharge angle:50

Air velocity [ft/s]

Air velocity [ft/s]

8.9ft

8.9ft

6.6ft

6.6ft
3.9
3.3

3.3
4.0ft

4.0ft

2.5

2.5
1.6
16.4ft

13.1ft

9.8ft

1.6

6.6ft

3.3ft

0ft

Temperature [F]

0ft

16.4ft

13.1ft

9.8ft

6.6ft

3.3ft

0ft

Temperature [F]

8.9ft

8.9ft

6.6ft

16.4ft

13.1ft

77
9.8ft

6.6ft

4.0ft

73.4

4.0ft

82.4
84.2

75.2
6.6ft

3.3ft

0ft

0ft

0ft

16.4ft

13.1ft

9.8ft

86
6.6ft

3.3ft

0ft

0ft

h Based on maximum air flow.

3.28 kW (12kBtu/h) LAN120HSV2 / LSN121HSV2 / LSN120HEV / LSN121HSV3 / LAN120HYV


Cooling

Heating

Discharge angle:45

Discharge angle:50
Air velocity [ft/s]

Air velocity [ft/s]


8.9ft

8.9ft

6.6ft

6.6ft
4.9

4.9
4.1

4.1

3.3

3.3
1.6
16.4ft

13.1ft

9.8ft

6.6ft

2.5
0ft

0ft

13.1ft

9.8ft

6.6ft

3.3ft

0ft

0ft

77
9.8ft

8.9ft

6.6ft

6.6ft

3.3ft

0ft

0ft

4.0ft

86
84.2

82.4

75.2
6.6ft

8.9ft

4.0ft

73.4

13.1ft

16.4ft

Temperature [F]

Temperature [F]

16.4ft

2.5

1.6
3.3ft

4.0ft

4.0ft

16.4ft

13.1ft

9.8ft

6.6ft

3.3ft

0ft

0ft

h Based on maximum air flow.

Inverter Single

90

Air flow and temperature distributions (reference data)

6RMI0-06A

5.33 kW (18kBtu/h) LAN180HSV2 / LSN181HSV2 / LSN180HEV / LSN181HSV3


Cooling

Heating

Discharge angle:45

Discharge angle:50

Air velocity [ft/s]

Air velocity [ft/s]

4.9

8.9ft

8.9ft

6.6ft

6.6ft
4.9

4.0ft

26.2ft

23ft

19.7ft

13.1ft

3.3

2.5

1.6
16.4ft

9.8ft

6.6ft

3.3ft

0ft

26.2ft 23ft

19.7ft

19.7ft

16.4ft

13.1ft

3.3

2.5
9.8ft

6.6ft

3.3ft

0ft

0ft

Temperature [F]

16.4ft

77
13.1ft

75.2
9.8ft

6.6ft

8.9ft

8.9ft

6.6ft

6.6ft
87.8

4.0ft

73.4

23ft

1.6

0ft

Temperature [F]

26.2ft

4.0ft

4.1

4.1

3.3ft

0ft

26.2ft 23ft

19.7ft

16.4ft

86

84.2

82.4

0ft

13.1ft

9.8ft

4.0ft
0ft

6.6ft

3.3ft

0ft

h Based on maximum air flow.

6.45 kW (24kBtu/h) LAN240HSV2 / LSN240HEV / LSN240HSV3


Cooling

Heating

Discharge angle:120

Discharge angle:105

Air velocity [ft/s]

Air velocity [ft/s]


8.9ft

8.9ft

6.6ft

6.6ft

11.5
4.0ft

9.8
4.9
26.2ft

23ft

19.7ft

6.6
16.4ft

13.1ft

9.8ft

6.6ft

3.3ft

0ft

26.2ft 23ft

Temperature [F]

6.6

4.9

0ft
19.7ft

16.4ft

13.1ft

4.0ft

11.5
9.8

8.2
9.8ft

6.6ft

3.3ft

0ft

0ft

Temperature [F]
8.9ft

8.9ft

6.6ft

6.6ft

62.6

95

4.0ft

4.0ft

91.4
66.2

69.8
26.2ft

23ft

19.7ft

16.4ft

13.1ft

9.8ft

6.6ft

3.3ft

0ft

26.2ft 23ft

h Based on maximum air flow.

91

87.8

84.2

0ft

Inverter Single

19.7ft

16.4ft

13.1ft

9.8ft

6.6ft

0ft
3.3ft

0ft

6RMI0-06A

Air flow and temperature distributions (reference data)

6.45 kW (24kBtu/h)/8.79 kW (30kBtu/h) LSN240HSV2 / LSN307HV2 / LSN307HV3


Cooling

Heating

Discharge angle:49

Discharge angle:65

Air velocity [ft/s]

Air velocity [ft/s]

9.8

11.5 13.1

23ft

19.7ft

16.4ft

13.1ft

9.8ft

6.6ft

8.9ft

6.6ft

6.6ft

4.0ft

8.2
26.2ft

8.9ft

3.3ft

0ft

4.0ft

26.2ft 23ft

Temperature [F]

8.2

6.6

0ft

19.7ft

16.4ft

13.1 14.8
9.8 11.5

13.1ft

9.8ft

6.6ft

3.3ft

Temperature [F]

68

8.9ft

6.6ft

6.6ft
93.2

4.0ft

71.6
16.4ft

13.1ft

9.8ft

6.6ft

3.3ft

0ft

86

82.4

0ft
19.7ft

4.0ft

89.6

71.6
23ft

0ft

8.9ft

64.4

26.2ft

0ft

26.2ft 23ft

19.7ft

16.4ft

13.1ft

9.8ft

0ft
6.6ft

3.3ft

0ft

h Based on maximum air flow.

9.67 kW (36kBtu/h) LSN360HV2 / LSN360HV3


Cooling

Heating

Discharge angle:49

Discharge angle:65

Air velocity [ft/s]

Air velocity [ft/s]

9.8

11.5 13.1

23ft

19.7ft

16.4ft

13.1ft

9.8ft

6.6ft

8.9ft

6.6ft

6.6ft

4.0ft

8.2
26.2ft

8.9ft

3.3ft

0ft

26.2ft 23ft

Temperature [F]

9.8

8.2

6.6

0ft

19.7ft

16.4ft

13.1ft

9.8ft

14.8
13.1
11.5
6.6ft

4.0ft

3.3ft

0ft

0ft

Temperature [F]
8.9ft

8.9ft

6.6ft

6.6ft

64.4

93.2

68

89.6

4.0ft

4.0ft

71.6
71.6
26.2ft

23ft

19.7ft

16.4ft

13.1ft

9.8ft

6.6ft

3.3ft

0ft

86

82.4

0ft
26.2ft 23ft

19.7ft

16.4ft

13.1ft

9.8ft

6.6ft

0ft
3.3ft

0ft

h Based on maximum air flow.

Inverter Single

92

Air flow and temperature distributions (reference data)

6RMI0-06A

Art Cool Premier Inverter 2.64 kW (9kBtu/h) - LSN090HYV


Cooling

Heating

Discharge angle:45

Discharge angle:50

AirVelocity [ft/s]

AirVelocity [ft/s]

8.9ft

8.9ft

6.6ft

6.6ft
1.23.9
1.2

3.3
1.01.0

1.0
3.3
1.0

4.0ft

4.0ft

0.75
2.5
0.75

2.5
0.75
0.75
1.60.5
0.5

0.5
1.6
0.5

0ft
16.4ft

13.1ft

9.8ft

6.6ft

3.3ft

0ft

Temperature [F]

0ft
16.4ft

13.1ft

9.8ft

6.6ft

3.3ft

0ft

Temperature [F]

8.9ft

8.9ft

6.6ft

6.6ft

4.0ft

73.4
2323

4.0ft
2984.2
29

7725
25

28
82.4
28

75.2
2424

3086
30

0ft
16.4ft

13.1ft

9.8ft

6.6ft

3.3ft

0ft

0ft
16.4ft

13.1ft

9.8ft

6.6ft

3.3ft

0ft

h Based on maximum air flow.

Art Cool Premier Inverter 3.28 kW (12kBtu/h) - LSN120HYV


Cooling

Heating

Discharge angle:45

Discharge angle:50

AirVelocity [ft/s]

AirVelocity [ft/s]

8.9ft

8.9ft
6.6ft

6.6ft
1.51.5
4.9

4.94.9

4.1
4.1
1.251.25

4.0ft
1.01.0
3.3
0.75
2.50.75

4.0ft

1.0
1.03.3
0.5
0.51.6

0.50.5
1.6

0.75
0.752.5

0ft

0ft
16.4ft

13.1ft

9.8ft

6.6ft

3.3ft

16.4ft

0ft

Temperature [F]

13.1ft

9.8ft

6.6ft

3.3ft

0ft

Temperature [F]

8.9ft

8.9ft

6.6ft

6.6ft

4.0ft

4.0ft

73.4
23 23
25 25
77

75.2
24 24

29
2984.2

28
2882.4

86
3030

0ft

0ft
16.4ft

13.1ft

9.8ft

6.6ft

3.3ft

0ft

16.4ft

h Based on maximum air flow.


93

Inverter Single

13.1ft

9.8ft

6.6ft

3.3ft

0ft

6RMI0-06A

Air flow and temperature distributions (reference data)

Art Cool Gallery 2.64kW(9kBtu/h) LAN090HVP


Cooling

Heating

Discharge angle:52

Discharge angle:52

Air velocity [ft/s]

8.9ft

Air velocity [ft/s]

8.9ft
6.6ft

6.6ft
6.6
4.9

4.9

4.0ft

4.0ft

3.3
1.6
16.4ft

13.1ft

9.8ft

3.3
0ft

3.3ft

6.6ft

Temperature [F]

1.6

0ft
16.4ft

8.9ft

13.1ft

0ft
0ft

3.3ft

6.6ft

9.8ft

Temperature [F]

8.9ft
6.6ft

6.6ft

59
62.6

104

4.0ft

4.0ft

100.4

16.4ft

13.1ft

9.8ft

69.8
6.6ft

66.2
0ft

3.3ft

89.6

0ft
16.4ft

13.1ft

93.2
0ft
0ft

3.3ft

6.6ft

9.8ft

h Based on maximum air flow.

Art Cool Gallery 3.28 kW(12kBtu/h) LAN120HVP


Cooling

Heating

Discharge angle:52

Discharge angle:52

Air velocity [ft/s]

Air velocity [ft/s]

8.9ft

8.9ft
6.6ft

6.6ft
3.9
4.0ft

3.3

4.0ft

3.3
2.5

1.6
16.4ft

13.1ft

9.8ft

2.5

1.6

3.3ft

6.6ft

0ft

Temperature [F]

0ft

0ft
16.4ft

13.1ft

6.6ft

9.8ft

3.3ft

0ft

Temperature [F]

8.9ft

8.9ft
6.6ft

6.6ft

86

4.0ft

73.4

4.0ft

84.2
75.2

77
16.4ft

13.1ft

9.8ft

6.6ft

3.3ft

0ft

82.4

0ft
16.4ft

13.1ft

9.8ft

0ft
6.6ft

3.3ft

0ft

h Based on maximum air flow.

Inverter Single

94

Sound level

6RMI0-06A

12. Sound levels (Reference data)


12.1 Indoor Units
Overall
Notes:
- Sound measured at 1m(3.28 ft) away from the unit.
- Data is valid at free field condition.
- Data is valid at nominal operation condition.
- Reference accoustic pressure 0dB=20Pa.
- Sound level will vary depending on a range of factors such as the
construction(acoustic absorption coefficient) of particular room in
which the equipment is installed.
- The operating conditions are assumed to be standard.

1m(3.28 ft)
0.8m
(2.62 ft)
Microphone

Sound Levels [dB(A)]


H
M
L
38
33
24
38
33
24
38
33
24
42
36
32
42
36
25
39
34
26
39
33
25
39
33
24
39
33
24
39
33
24
39
33
25
42
36
32
42
36
25

Model
ASNW093B1B8 [LSN091HSV3]
ASNW093B1Y9 [LSN091HSV2]
ASNW093BRM9 [LAN090HSV2]
ASNW093F2B2 [LAN090HVP]
ASNW093MMB8 [LAN090HYV]
ASNW093MMM9 [LSN090HYV]
ASNW093WSA7 [LSN090HEV]
ASNW123B1B8 [LSN121HSV3]
ASNW123B1Y9 [LSN121HSV2]
ASNW123BRM9 [LAN120HSV2]
ASNW123BSA7 [LSN120HEV]
ASNW123F2B2 [LAN120HVP]
ASNW123MMB8 [LAN120HYV]

Sound Levels [dB(A)]


H
M
L
39
34
26
45
40
35
45
40
35
45
40
35
42
40
35
45
40
35
45
40
35
46
43
39
46
43
39
49
44
39
49
44
39
49
44
39
49
44
39

Model
ASNW123MMM9 [LSN120HYV]
ASNW183C2B8 [LSN181HSV3]
ASNW183C2Y9 [LSN181HSV2]
ASNW183CRM9 [LAN180HSV2]
ASNW183CSA7 [LSN180HEV]
ASNW243CRM9 [LAN240HSV2]
ASNW243CSA7 [LSN240HEV]
ASNW243D8B8 [LSN240HSV3]
ASNW243DGY9 [LSN240HSV2]
ASNW303D8B8 [LSN307HV3]
ASNW303DGY9 [LSN307HV2]
ASNW363D8B8 [LSN360HV3]
ASNW363DGY9 [LSN360HV2]

Sound pressure level

80

70

70

NC-65

NC-60
NC-55

50
NC-50
NC-45

40

NC-40
NC-35

30

NC-30

NC-25

20

Approximate
Hearing
Threshold
10
63

125

250

500

1000

2000

4000

Octave Band Center Frequency (Hz)

95

NC-65

60
NC-60
NC-55

50
NC-50

8000

NC-45

40

NC-40
NC-35

30

NC-30

NC-25

20

Approximate
Hearing
Threshold

NC-20
NC-15

80

70

NC-15

125

250

500

1000

2000

4000

Octave Band Center Frequency (Hz)

Inverter Single

8000

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20

NC-20

10
63

Octave Band Sound Pressure Level (0dB = 20Pa)

80

60

ASNW183C2B8(LSN181HSV3)
ASNW183C2Y9(LSN181HSV2)
ASNW183CRM9(LAN180HSV2)
ASNW243CRM9(LAN240HSV2)

ASNW093B1B8(LSN091HSV3)
ASNW093B1Y9(LSN091HSV2)
ASNW093BRM9(LAN090HSV2)

Octave Band Sound Pressure Level (0dB = 20Pa)

Octave Band Sound Pressure Level (0dB = 20Pa)

ASNW121B1B8(LSN121HSV3)
ASNW123B1Y9(LSN121HSV2)
ASNW123BRM9(LAN120HSV2)

10

Approximate
Hearing
Threshold
63

125

NC-20

250

500

NC-15
1000 2000 4000 8000

Octave Band Center Frequency (Hz)

6RMI0-06A

Sound level

ASNW303D8B8(LSN307HV3)
ASNW303DGY9(LSN307HV2)
80

70

70

70

NC-65

60
NC-60
NC-55

50
NC-50
NC-45
NC-40
NC-35

30

NC-30

NC-25

Approximate
Hearing
Threshold

NC-55

50
NC-50
NC-45

40
NC-40
NC-35

30
NC-30

Approximate
Hearing
Threshold

NC-15

125

250

500

1000

2000

4000

NC-25

20

NC-20

10
63

NC-60

63

125

ASNW093MMM9(LSN090HYV)
ASNW123MMM9(LSN120HYV)

NC-65
NC-60
NC-55
NC-50
NC-45
NC-40
NC-35

30

NC-30
NC-25

20

10

Octave Band Sound Pressure Level (0dB = 20Pa)

Octave Band Sound Pressure Level (0dB = 20Pa)

70

40

Approximate
Hearing
Threshold
63

250

500

250

500

1000

2000

4000

NC-40

NC-30

63

8000

NC-65
NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30

NC-15
1000 2000 4000 8000

10

Approximate
Hearing
Threshold
63

20

125

250

500

NC-15
1000 2000 4000 8000

10
63

Octave Band Sound Pressure Level (dB re 20Pa )

Octave Band Sound Pressure Level (0dB = 20Pa)

60

50

40

30

2000

4000

Octave Band Center Frequency (Hz)

8000

500

1000

2000

4000

8000

60

50

40

30

20

10

10

1000

250

ASNW093MMB8(LAN090HYV)
ASNW123MMB8(LAN120HYV)

ASNW243CSA7(LSN240HEV)

20

500

125

Octave Band Center Frequency (Hz)

70

10

8000

NC-20

70

20

4000

30

70

30

2000

40

80

40

1000

50

80

50

500

60

Octave Band Center Frequency (Hz)

60

250

ASNW093WSA7(LSN090HEV)
ASNW123BSA7(LSN120HEV)

NC-25

20

NC-15

125

Octave Band Center Frequency (Hz)

70

60

NC-20

10

70

ASNW183CSA7(LSN180HEV)

250

NC-25

Approximate
Hearing
Threshold

80

125

NC-35

30

80

Octave Band Center Frequency (Hz)

63

NC-45

40

80

NC-20

125

NC-50

ASNW093F2B2(LAN090HVP)
ASNW123F2B2(LAN120HVP)

80

50

NC-55

50

Octave Band Center Frequency (Hz)

Octave Band Center Frequency (Hz)

60

NC-60

20

NC-15

10

8000

NC-65

60

NC-20

Octave Band Sound Pressure Level (0dB = 20Pa)

40

NC-65

60

Octave Band Sound Pressure Level (0dB = 20Pa)

80

20

Octave Band Sound Pressure Level (0dB = 20Pa)

ASNW363D8B8(LSN360HV3)
ASNW363DGY9(LSN360HV2)

80

Octave Band Sound Pressure Level (0dB = 20Pa)

Octave Band Sound Pressure Level (0dB = 20Pa)

ASNW243D8B8(LSN240HSV3)
ASNW243DGY9(LSN240HSV2)

63

125

250

500

1000

2000

4000

Octave Band Center Frequency (Hz)

Inverter Single

8000

63

125

250

500

1000

2000

4000

8000

Octave Band Center Frequency (Hz)

96

Sound level

6RMI0-06A

12.2 Outdoor Units


Overall
Notes:
- Sound measured at 1m(3.28 ft) away from the center of the unit.
- Data is valid at free field condition.
- Data is valid at nominal operation condition.
- Reference accoustic pressure 0dB=20Pa.
- Sound level will vary depending on a range of factors such as the
construction(acoustic absorption coefficient) of particular room in
which the equipment is installed.
- The operating conditions are assumed to be standard.

Center of
Outdoor Unit
1m(3.28 ft)

Sound Levels [dB(A)]


H
45
45
45
45
45
51
47
Center of
Outdoor Unit
45
45
45
47
45
45

Model
ASUW093B1B8 [LSU091HSV3]
ASUW093B1Y9 [LSU091HSV2]
ASUW093BRM9 [LAU090HSV2]
ASUW093FUB2 [LAU090HVP]
ASUW093MMB8 [LAU090HYV]
ASUW093MMM9 [LSU090HYV]
ASUW093WSA7 [LSU090HEV ]
ASUW123B1B8 [LSU121HSV3]
ASUW123B1Y9 [LSU121HSV2]
ASUW123BRM9 [LAU120HSV2]
ASUW123BSA7 [LSU120HEV]
ASUW123FUB2 [LAU120HVP]
ASUW123MMB8 [LAU120HYV]

Model
ASUW123MMM9 [LSU120HYV]
ASUW183C2B8 [LSU181HSV3]
ASUW183C2Y9 [LSU181HSV2]
ASUW183CRM9 [LAU180HSV2]
ASUW183CSA7 [LSU180HEV]
ASUW243CRM9 [LAU240HSV2]
ASUW243CSA7 [LSU240HEV]
ASUW243D8B8 [LSU240HSV3]
ASUW243DGY9 [LSU240HSV2]
ASUW303D8B8 [LSU307HV3]
ASUW303DGY9 [LSU307HV2]
ASUW363D8B8 [LSU360HV3]
ASUW363DGY9 [LSU360HV2]

Sound Levels [dB(A)]


H
51
53
53
53
51
53
53
54
54
55
55
55
55

Sound pressure level


ASUW183C2B8(LSU181HSV3)
ASUW183C2Y9(LSU181HSV2)
ASUW183CRM9(LAU180HSV2)
ASUW243CRM9(LAU240HSV2)

ASUW123B1B8(LSU121HSV3)
ASUW123B1Y9(LSU121HSV2)
ASUW123BRM9(LAU120HSV2)
80

80

70

70

70

NC-65

60
NC-60

NC-55

50
NC-50

NC-45

40
NC-40

NC-35

30
NC-30

20

NC-25

Approximate
Hearing
Threshold

NC-15

125

250

500

1000

2000

4000

Octave Band Center Frequency (Hz)

97

NC-60

8000

NC-55

50

NC-50
NC-45

40

NC-40

NC-35

30

NC-30

20

NC-25

Approximate
Hearing
Threshold

NC-20

10
63

NC-65

60

NC-15

125

250

500

1000

2000

4000

Octave Band Center Frequency (Hz)

Inverter Single

8000

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20

NC-20

10
63

Octave Band Sound Pressure Level (0dB = 20Pa)

80

Octave Band Sound Pressure Level (0dB = 20Pa)

Octave Band Sound Pressure Level (0dB = 20Pa)

ASUW093B1B8(LSU091HSV3)
ASUW093B1Y9(LSU091HSV2)
ASUW093BRM9(LAU090HSV2)

10

Approximate
Hearing
Threshold
63

125

NC-20
NC-15
250

500

1000

2000

4000

Octave Band Center Frequency (Hz)

8000

6RMI0-06A

Sound level

ASUW093MMM9(LSU090HYV)
ASUW123MMM9(LSU120HYV)
80

70

70

70

NC-65

60
NC-60
NC-55

50
NC-50
NC-45

40
NC-40
NC-35

30
NC-30

NC-25

NC-65

60
NC-60
NC-55

50
NC-50
NC-45

40
NC-40
NC-35

30
NC-30

NC-25

20

Approximate
Hearing
Threshold

NC-20
NC-15

10
63

Approximate
Hearing
Threshold

125

250

10

500 1000 2000 4000 8000

63

NC-65

60
NC-60
NC-55

50
NC-50
NC-45

40
NC-40
NC-35

30
NC-30

Approximate
Hearing
Threshold

NC-15

125

250

500

1000

2000

4000

10

8000

ASUW093WSA7(LSU090HEV)

ASUW123BSA7(LSU120HEV)
70

70

NC-65

NC-60

NC-55

NC-50
NC-45

NC-40

NC-35

30

NC-30

20

NC-25

Approximate
Hearing
Threshold

NC-60

NC-55

50
NC-50

NC-45

40
NC-40

NC-35

30
NC-30

20

NC-15

125

250

500

1000

2000

4000

NC-25

Approximate
Hearing
Threshold

NC-20

10
63

NC-65

60

8000

NC-15

63

125

70

70

NC-65
NC-60
NC-55
NC-50
NC-45
NC-40
NC-35

30

NC-30
NC-25

20

10

Approximate
Hearing
Threshold
63

Octave Band Sound Pressure Level (dB re 20Pa )

80

40

250

500

NC-15
1000 2000 4000 8000

Octave Band Center Frequency (Hz)

2000

4000

1000

2000

4000

8000

NC-65
NC-60

8000

NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20

10

Approximate
Hearing
Threshold
63

NC-20
NC-15
125

250

500

1000

2000

4000

8000

Octave Band Center Frequency (Hz)

NC-65

60
NC-60
NC-55

50
NC-50
NC-45

40

NC-40
NC-35

30

NC-30

NC-25

20

Approximate
Hearing
Threshold

NC-20

125

1000

500

ASUW093MMB8(LAU090HYV)
ASUW123MMB8(LAU120HYV)

80

50

500

Octave Band Center Frequency (Hz)

ASUW243CSA7(LSU240HEV)

60

250

250

60

NC-20

10

Octave Band Center Frequency (Hz)

Octave Band Sound Pressure Level (0dB = 20Pa)

70

Octave Band Sound Pressure Level (0dB = 20Pa)

80

60

NC-15

125

ASUW183CSA7(LSU180HEV)

80

40

63

NC-20

Octave Band Center Frequency (Hz)

80

50

NC-25

20

NC-20

Octave Band Center Frequency (Hz)

Octave Band Center Frequency (Hz)

Octave Band Sound Pressure Level (0dB = 20Pa)

Octave Band Sound Pressure Level (0dB = 20Pa)

80

20

Octave Band Sound Pressure Level (0dB = 20Pa)

ASUW093FUB2(LAU090HVP)
ASUW123FUB2(LAU120HVP)

80

Octave Band Sound ressure Level (0dB = 20Pa)

Octave Band Sound Pressure Level (0dB = 20Pa)

ASUW243D8B8(LSU240HSV3),
ASUW243DGY9(LSU240HSV2),
ASUW303D8B8(LSU307HV3),
ASUW303DGY9(LSU307HV2),
ASUW363DGY9(LSU360HV2),
ASUW363D8B8(LSU360HV3)

NC-20
NC-15

10
63

125

250

500

1000

2000

4000

8000

Octave Band Center Frequency (Hz)

Inverter Single

98

Remote controller

6RMI0-06A

13. Remote controller


Wireless Remote Controller
P/No: AKB73635606

Display
screen

Control
panel

Display
screen

Sleep mode auto button*: Sets the sleep mode


auto operation.

Temperature adjustment buttons: Adjusts the


room temperature when cooling and heating.

g 7 v
Control
panel

A C
D B
E

i jH I
Applied Model
: LS090HYV / LS120HYV /
LA090HVP / LA120HVP /
LS091HSV2 / LS121HSV2 /
LS181HSV2 / LA090HSV2 /
LA120HSV2 / LA180HSV2 /
LA240HSV2

m nz
c
b

J G
P

Description
Plasma button*: Purifies the air by removing
particles that enter the indoor unit.

On/Off button: Turns the power on/off.


Indoor fan speed button: Adjusts the fan speed.
Operation mode selection button*: Selects
the operation mode.
Cooling operation (A) / Auto operation or
auto changeover (C) / Dehumidifying
operation (D) / Heating operation (B) / Air
circulation (E)
Jet cooling/heating button*: Warms up or
cools down the indoor temperature within a
short period of time.
Air flow direction button: Adjusts the air flow
direction vertically or horizontally.
Temperature display button: Displays
the room temperature. Also changes unit
from C to F if pressed for 5 seconds.
Timer button: Sets the current time and the
start / end time.
Navigation and functions button*: Adjusts
the time and sets the special functions.
J: Auto clean / G: Operates energy saving
cooling / P: Adjusts the brightness of the
indoor unit display

Set/clear button: Sets or cancels functions.

Reset button: Resets the air conditioner


settings.

* Some functions may not be supported, depending on the model.

99

Inverter Single

6RMI0-06A

Remote controller

P/No: AKB73835305

Display
screen

Control
panel

Applied Model
LS090HEV, LS120HEV
LS180HEV, LS240HEV

Control
panel

Display
screen

Description

Fan button : Air come out from the indoor unit


below to the room without air temperature
change.

P
O

J G

Functions button*: Sets the special


functions.
J: Auto clean / G: Operates energy saving
cooling
On/Off button: Turns the power on/off.
Temperature adjustment buttons: Adjusts
the room temperature when cooling and
heating.

Operation mode selection button*: Selects


the operation mode.
A C
Cooling operation (A) / Auto operation or auto
D B changeover (C) / Dehumidifying operation (D)
/ Heating operation (B)

g 7 v

Indoor fan speed button: Adjusts the fan


speed.

Jet cooling/heating button*: Warms up or


cools down the indoor temperature within a
short period of time.

Air flow direction button: Adjusts the air flow


direction vertically.

LIGHT button: Adjusts the brightness of the


indoor unit display.

Temperature display button: Displays the


room temperature. Press k for
5 sec, conversion C / F

Sleep mode auto button*: Sets the sleep


mode auto operation.

m nz

Timer button: Sets the current time and the


start / end time.

EF

Time adjustment buttons*:


Adjusts the time

Set/clear button: Sets or cancels functions.

Reset button : Resets the remote control


settings.

* Some functions may not be supported, depending on the model.

Inverter Single

100

Remote controller

6RMI0-06A

The controls will look like the following.

9
12
17
19
18
14

1. START/STOP BUTTON
Used to turn off/on the unit.
2. OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
3. ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
4. INDOOR FAN SPEED SELECTOR BUTTON
Used to select fan speed in four steps
low, medium, high and CHAOS.
5. JET COOL/HEAT BUTTON
Used to start or stop the speed cooling/heating.
(It operates fan in super high speed)
6. CHAOS SWING BUTTON
Used to stop or start louver movement and set the
desired up/down airflow direction.
7. ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping
operation.
8. TIME SETTING BUTTONS
Used to adjust the time.
9. TIMER SET/CANCEL BUTTON
Used to set and to cancel the timer operation.
10. SLEEP MODE AUTO BUTTON
Used to set sleep mode auto operation.

16

11.

P/No:6711A20128R
Signal transmitter

6
3
4
10

2
7
11
8
13

CANCEL
ON

OFF

SET
AUTO CLEAN

15

Flip-up door
(opened)

Operation Mode
Cooling Operation
Auto Operation or Auto Changeover

Healthy Dehumidification Operation


Heating Operation

Cooling Model(

), Heat Pump Model(

Applied Model
: LS240HSV2 / LS307HV2 / LS360HV2

AIR CIRCULATION BUTTON(OPTIONAL)


Used to circulate the room air without cooling or heating.
ENERGY-SAVING COOLING MODE BUTTON
(OPTIONAL) For inverter type models
12. ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
13. PLASMA BUTTON(OPTIONAL)
Used to start or stop the plasma-purification function.
14. HORIZONTAL AIRFLOW DIRECTION CONTROL
BUTTON (OPTIONAL)
Used to set the desired horizontal airflow direction.
15. RESET BUTTON
Used prior to resetting time.
16. 2nd F BUTTON
Used prior to using modes printed in blue at the
bottom of buttons.
17. AUTO CLEAN BUTTON(OPTIONAL)
Used to set auto clean mode.
In some models this button has a 2nd function of LED
luminosity control.
18. C TO F SWITCHING BUTTON
Used to switch temperature reading from Centigrade to
Fahrenheit.
19. LCD LUMINOSITY BUTTON(OPTIONAL)
Used to adjust LCD luminosity.

NOTICE
To use the functions printed in blue at the bottom of the buttons press 2nd F button first and then the required
functionbutton.
Pressing the 2ndF button activates the blue printed function of the respective button. To cancel the functionpress
the 2nd F button again else it will automatically cancel if remains idle after 10 seconds.

101

Inverter Single

6RMI0-06A

Remote controller

P/No. : AKB73835312

Display
screen

Control
panel

Display
screen

Sleep mode auto button*: Sets the sleep


mode auto operation.

Temperature adjustment buttons: Adjusts


the room temperature when cooling and
heating.

d
g 7 v

Control
panel

i jH

Plasma button*: Purifies the air by removing


particles that enter the indoor unit.

On/Off button: Turns the power on/off.


Indoor fan speed button: Adjusts the fan
speed.

Operation mode selection button*: Selects


A C the operation mode.
D B Cooling operation (A) / Auto operation or auto
changeover (C) / Dehumidifying operation (D)
E
/ Heating operation (B) / Air circulation (E)

Applied Model
LA090HYV, LA120HYV

Description

Jet cooling/heating button*: Warms up or


cools down the indoor temperature within a
short period of time.

Air flow direction button: Adjusts the air flow


I direction vertically or horizontally.

m nz

Temperature display button: Displays the


room temperature. Press key and hold it for
longer than 5 second.
Display change C/F
Timer button: Sets the current time and the
start / end time.

c
b

J G

Navigation and functions button*: Adjusts


the time and sets the special functions.
J: Auto clean / G: Operates energy saving
cooling

Set/clear button: Sets or cancels functions.

Reset button: Resets the air conditioner


settings.

Light button : Adjusts the brightness of the


indoor unit display

* Some functions may not be supported, depending on the model.

Inverter Single

102

Remote controller

6RMI0-06A

P/No. : AKB73855713

Display
screen

Control
panel

Control
panel

Display
screen

Description

Fan button : Air come out from the indoor unit


below to the room without air temperature
change.

Sleep mode auto button*: Sets the sleep


mode auto operation.

Temperature adjustment buttons:


Adjusts the room temperature when cooling
and heating.

Indoor fan speed button: Adjusts the fan


speed.

Operation mode selection button*: Selects


the operation mode.
A C
Cooling operation (A) / Auto operation or auto
D B changeover (C) / Dehumidifying operation (D)
/ Heating operation (B)
Jet cooling/heating button*: Warms up or
cools down the indoor temperature within a
short period of time.

M
DE IJ
Applied Model
LS240HSV3, LS307HV3
LS360HV3

On/Off button: Turns the power on/off.

Air flow direction button: Adjusts the air flow


direction vertically or horizontally.
Adjusts the brightness of the indoor unit
display.
Temperature display button: Displays the
room temperature. Also changes unit from C
to F if pressed for 5 seconds.

m n

Timer button: Sets the current time


and the start / end time.

O
P

J G

Navigation and functions button*:


Sets the special functions.
J: Auto clean
G: Operates energy saving cooling

Set/clear button: Sets or cancels functions.

Reset button: Resets the air conditioner


settings.

* Some functions may not be supported, depending on the


model.

103

Inverter Single

6RMI0-06A

Remote controller

P/No. : AKB73855712

Display
screen

Control
panel

Control
panel

Display
screen

Description

Fan button : Air come out from the indoor unit


below to the room without air temperature
change.

Sleep mode auto button*: Sets the sleep


mode auto operation.

Temperature adjustment buttons:


Adjusts the room temperature when cooling
and heating.

Indoor fan speed button: Adjusts the fan


speed.

Operation mode selection button*: Selects


the operation mode.
A C
Cooling operation (A) / Auto operation or auto
D B changeover (C) / Dehumidifying operation (D)
/ Heating operation (B)
Jet cooling/heating button*: Warms up or
cools down the indoor temperature within a
short period of time.

M
DE IJ
Applied Model
LS091HSV3, LS121HSV3,
LS181HSV3

On/Off button: Turns the power on/off.

Air flow direction button: Adjusts the air flow


direction vertically or horizontally.
Adjusts the brightness of the indoor unit
display.
Temperature display button: Displays the
room temperature. Also changes unit from C
to F if pressed for 5 seconds.

m n

Timer button: Sets the current time


and the start / end time.

O
P

J G

Navigation and functions button*:


Sets the special functions.
J: Auto clean
G: Operates energy saving cooling

Set/clear button: Sets or cancels functions.

Reset button: Resets the air conditioner


settings.

* Some functions may not be supported, depending on the model.

Inverter Single

104

Installation

6RMI0-06A

14. Installation
Installation Map

Installation plate
Sleeve
Bushing-Sleeve
Putty(Gum Type Sealant)
Bend the pipe as closely
on the wall as possible,
but be careful that it
doesn't break.

Vinyl tape (Wide)

Saddle

Apply after carrying out a


drainage test.
To carry out the drainage
test, remove the air filters
and pour water into the heat
exchanger.

Gas side piping


(Optional Parts)
Liquid side piping
(Optional Parts)
Additional drain pipe
Vinyl tape (Narrow)
Drain Hose
Connecting cable
(Optional Parts)

NOTICE
You should purchase the installation parts.

105

Inverter Single

6RMI0-06A

Installation

Select the best Location


Indoor unit
1. There should not be any heat or steam near the unit.

minimum distance
to the side : 100mm(4in)

2. Select a place where there are no obstacles around of


the unit.

minimum distance
to the ceiling : 200mm(8in)

3. Make sure that condensation drainage can be


conveniently routed away.

minimum distance
to the side : 100mm(4in)

4. Do not install near a doorway.


5. Ensure that the interval between a wall and the left(or
right) of the unit is more than 100mm(4in) for wall
mounted model, more than 500mm(20in) for Art cool
Gallery model.
The unit should be installed as high as possible on the
wall, allowing a minimum of 200m(8in) for ceiling.
6. Use a metal detector to locate studs to prevent
unnecessary damage to the wall.

Unit : mm(inch)

minimum distance
to the ceiling : 200mm(8in)

minimum distance
to the side : 500mm(20in)

7. Recommended height 2m(6.5ft) for wall mounted


model, more than 1.5m(5ft) for Art Cool Gallery.

minimum distance
to the side : 500mm(20in)
Unit : mm(inch)

NOTICE
Remove obstructions to prevent blockage of airflow path.

Outdoor unit
1. If an awning is built over the unit to prevent direct
sunlight or rain exposure, make sure that heat radiation
from the condenser is not restricted.

More than

300(11 13/16)

2. Ensure that the space around the back and sides is


more than 300mm(11 13/16 inch). The space in front of
the unit should be more than 700mm(27 19/32 inch) of
space.

Su
nro
of

Fe
ob nce
sta or
cle
s

3. Do not place animals and plants in the path of the


warm air.
4. Take the weight of the air conditioner into account and
select a place where noise and vibration are minimum.
5. Select a place where the warm air and noise from the
air conditioner do not disturb neighbors.

* All Outdoor Units

Inverter Single

More than
300(11 13/16)
More than
600(23 19/32)
More than
700(27 19/32)
Unit : mm(inch)

106

Installation

6RMI0-06A

Fixing Installation Plate


The wall you select should be strong and solid enough
to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a concrete
wall, use anchor bolts.
Mount the installation plate horizontally by aligning
the centerline using a level gauge.
2. Measure the wall and mark the centerline. It is also
important to use caution concerning the location of
the installation plate. Routing of the wiring to power
outlets is through the walls typically. Drilling the hole
through the wall for piping connections must be done
safely.

Type 1

Installation Plate

Type "A" Screws

Chassis
Hook

Place a level on raised tab


Unit Outline
442(17 13/32)

442(17 13/32)

70(2 11/16)
70(2 11/16)
70(2.76)
70(2.76
70(2.76)

Installation Plate

Right rear piping

Left rear piping


95(3 11/16)

133(5 3/16)
175(6 29/32)

217(8 1/2)

[Unit : mm(inch)]
Applied Model
: LS091HSV2/LS121HSV2/LA090HSV2/LA120HSV2/LS091HSV3/LS121HSV3

Type 2

Place a level on raised tab


Unit Outline
460(18 3/32)

65(2 19/32)

570(22 13/32)

Installation Plate

Left rear
piping

Measuring Tape
69(2 11/16)
105(4 3/32)
Measuring Tape
Hanger

Applied Model
: LS181HSV2/LA180HSV2/LA240HSV2/LS181HSV3

107

Inverter Single

65(2 19/32)
Right rear
piping
56(2 3/16)
207(8 3/32)

[Unit : mm(inch)]

6RMI0-06A

Installation

Type 3

335(13 3/16)

780(30 11/16)

858(33 13/16)
[Unit : mm(inch)]

Applied Model : LS240HSV2/LS307HV2/LS360HV2

Type 4

Place a level on raised tab


Unit Outline
439(17 5/16)

65(2 9/16)
Installation Plate
5
170(6 11/16)

123(4 13/16)
175(6 29/32)

217(8 17/32)

[Unit : mm(inch)]

Applied Model : LS090HYV, LS120HYV

Type 5

Right rear piping

65(2 9/16)

Left rear piping

Place a level on raised tab


Unit Outline
14.88(378mm)
14.88(378mm)

65

65

Installation Plate

5.71(145mm)

(Unit : in)

Right rear piping

Left rear piping

434(17)

2.95(75mm)
7.56(192mm)

7.56(192mm)

[Unit : mm(inch)]

Applied Model : LSN090HEV

Inverter Single

108

Installation

6RMI0-06A

Type 6
16.22(412mm)

18.90(480mm)

Unit Outline

65

65

Place a level on raised tab


Installation Plate

Left Rear
Piping

Right Rear
Piping

4.84
(123mm)

5.35
(136mm)

7(178mm)

9.65(245mm)
[Unit : mm(inch)]

Applied Model : LSN120HEV

Type 7

Place a level on raised tab


Unit Outline
18.11in (460mm)
22.44in (570mm)

65
Left
rear
piping

Installation Plate
Measuring Tape
2.72in
(69mm)
4.13in
(105mm)

65

2.20in
(56mm)
Measuring Tape
Hanger

Right
rear
piping

8.15 in
(207mm)
[Unit : mm(inch)]

Applied Model : LSN180HEV , LSN240HEV

Type 8

43(1 11/16)

43(1 11/16)
120(4 11/16)

Installation plate

Left rear piping

110(4 11/32)
Right rear piping
[Unit : mm(inch)]

Applied Model : LSN240HSV3, LSN307HV3, LSN360HV3

109

Inverter Single

6RMI0-06A

Installation

Type 9
Place a level on raised tab
A Type : 442(17 13/32)
A Type : 442(17 13/32)
B Type : 434(17)
B Type : 439(17 5/16)

65(2 19/32)
65

65(2 19/32)
Installation Plate
A Type
175(6 29/32)

B Type

A Type : 133(5 3/16)


B Type : 123(4 13/16)

A Type : 95(3 11/16)


B Type : 170(6 11/16)

217(8 1/2)

Right rear piping

Left rear piping

Unit
Outline

[Unit : mm(inch)]

Applied Model : LAN090HYV, LAN120HYV

Drill a Hole in the Wall


WALL
Outdoor

Inverter Single

(3/16in~5/16in)

Indoor

5-7mm

Drill the piping hole with a 70mm(2 13/16 inch) hole


core drill. Drill the piping hole at either the right or the
left with the hole slightly slanted to the outdoor side.

110

Installation

6RMI0-06A

Flaring Work
One cause of gas leakage is improper workmanship in flaring. Carry out correct flaring work in the following
procedure.

Cut the pipes and the cable.


1. Use the piping kit accessory or the pipes purchased
locally.
2. Measure the distance between the indoor and the
outdoor unit.
3. Cut the pipes a little longer than measured distance.
4. Cut the cable 1.5m(59 3/32 inch) longer than the pipe
length.

Copper
pipe

Slanted Uneven Rough

90

Burrs removal

Pipe

1. Completely remove all burrs from the cut cross section


of pipe/tube.

Reamer

2. While removing burrs put the end of the copper


tube/pipe in a downward direction while removing
burrs location is also changed in order to avoid
dropping burrs into the tubing.

Point down

Flare nut

Putting nut on
Remove flare nuts attached to indoor and outdoor unit,
then put them on pipe/tube having completed burr
removal.
(not possible to put them on after finishing flare work)

Copper tube

Flaring work

Outside diameter
mm
inch
6.35
1/4
9.52
3/8
12.7
1/2
15.88
5/8
19.05
3/4

Bar

A
mm
1.1~1.3
1.5~1.7
1.6~1.8
1.6~1.8
1.9~2.1

Bar
Yoke

inch
0.043~0.051
0.059~0.067
0.063~0.071
0.063~0.071
0.075~0.083

2. Carry out flaring work with the flaring tool.

111

Handle

"A"

1. Firmly hold copper pipe in a bar with the


dimension shown in table below.

Inverter Single

Cone
Copper pipe
Clamp handle

Red arrow mark

6RMI0-06A

Installation

Check
Smooth all round

1. Compare the flared work with the figure by.

Inside is shiny without scratches

2. If a section is improperly flared, cut it off and perform


flaring work again.

= Improper flaring =

Inclined Surface Cracked Uneven


damaged
thickness

Even length
all round

Connecting the Piping


Indoor unit
1. Pull the screw cap at the bottom of the indoor unit
2. Remove the chassis cover from the unit by loosing 2
screws
Chassis cover

3. Pull back the tubing holder.

Indoor unit back side view

4. Remove pipe port cover and positioning the tubing


Pipe Port
Left
Tubing holder

Right

Backwards

Drain hose

Inverter Single

112

Installation

6RMI0-06A

Installation Information. For right piping. Follow the instruction below.

Good case
Press on the tubing cover and unfold the tubing to downward slowly. And then bend to the left side slowly.

Bad case
Following bending case from right to left directly may cause damage to the tubing.

113

Inverter Single

6RMI0-06A

Installation

Installation of Indoor Unit


1. Hook the indoor unit onto the upper portion of the
installation plate.( engage the three hooks at the top of
the indoor unit with the upper edge of the installation
plate) Ensure that the hooks are properly seated on the
installation plate by moving it left and right
Installation plate

2. Unlock the tubing holder from the chassis and mount


between the chassis and installation plate in order to
separate the bottom side of the indoor unit from the
wallwall

Tubing Holder

Piping
1. Insert the connecting cable through the bottom side of indoor unit and connect the cable (You can see detail contents
in 'Connecting the cables' section)
<Left side piping>

<Right side piping>

View

View

Terminal block
Connecting cable
Cable retainer

Terminal block
Connecting cable
Cable retainer

2. Secure the cable onto the control board with the cable retainer.
3. Tape the tubing pipe, drain hose and the connection cable. Be sure that the drain hose is located at the lowest side
of the bundle. Locating at the upper side can cause overflow from the drain pan through the inside of the unit.

Inverter Single

114

Installation

6RMI0-06A

If the drain hose is routed inside the room insulate the hose with an insulation material* so that dripping from
sweating (condensation) will not damage furniture or floors.
Be sure to install in the sequence of Connecting cable (Conduit), Drain hose and Connecting pipe as the picture
below describes.
* Foamed polyethylene or equivalent is recommended.
<Left side piping>

<Right side piping>

Tape
Connecting
cable(conduit

Tape

Drain hose
Connecting pipe

Connecting
cable(conduit)
Drain hose
Connecting pipe

Connecting
cable

Gas side piping

Drain hose

Liquid side
piping

Loop

Connecting the installation pipe and


drain hose to the indoor unit.
1. Align the center of the pipes and sufficiently tighten the
flare nut by hand
Indoor unit tubing

Flare nut

Pipes

2. Tighten the flare nut with a wrench

Outside diameter
mm
6.35
9.52
12.7
15.88

inch
1/4
3/8
1/2
5/8

Open-end wrench (fixed)

Torque
kgf.m
1.8~2.5
3.4~4.2
5.5~6.6
6.3~8.2

lbf.ft
13~18
24.6~30.4
39.8~47.7
45.6~59.3

3. When needed to extend the drain hose of indoor unit,


assembly the drain pipe as shown on the drawing

Flare nut
Wrench

Connection pipe

Indoor unit tubing

Drain pipe

Indoor unit drain hose


Adhesive

115

Inverter Single

Vinyl tape(narrow)

6RMI0-06A

Installation

Wrap the insulation material around


the connecting portion.

Insulation material

1. Overlap the connection pipe insulation material and the


indoor unit pipe insulation material. Bind them together
with vinyl tape so that there may be no gap.
Cutting Line

2. Set the tubing cutting line upward.


Wrap the area which accommodates the rear piping
housing section with vinyl tape.
Cutting Line

Gas Pipe Liquid Pipe


Good Case

Bad Case

* Tubing cutting line have to be upward.


Indoor unit pipe

Connection pipe

Wrap with vinyl tape


Vinyl tape (wide)
Connecting cable

h both refrigerant pipes (liquid and gas) must be


insulated between the ODU and IDU, not just the
connection.

Pipe
Vinyl tape(narrow)

3. Bundle the piping and drain hose together by wrapping


them with vinyl tape sufficient enough to cover where
they fit into the rear piping housing section.

Wrap with vinyl tape


Pipe

Vinyl tape(wide)
Drain hose

Finishing the indoor unit installation


1. Mount the tubing holder in the original positon.
2. Ensure that the hooks are properly seated on the
installation plate by moving it left and right.
3. Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots (clicking sound).
Type 'C' screw

4. Finish the assembly by screwing the unit to the


installation plate by using two pieces of type "C"
screws. And assemble a chassis cover.

Installation of filters
1. Detach two attached tapes from the plasma filter.
Applied Model with Plasma Filter :
LS091HSV2/LS121HSV2/LS181HSV2/
LA090HSV2/LA120HSV2/LA180HSV2/LA240HSV2/
LS240HSV2/LS307HV2/LS360HV2

(All filters can be replaced.)

Inverter Single

Plasma Filter

116

Installation

6RMI0-06A

Outdoor unit
1. Remove the tubing cover from the unit by loosening
the screw.

Tubing cover

2. Align the center of the pipings and sufficiently tighten


the flare nut by hand.

3. Finally, tighten the flare nut with torque wrench until


the wrench clicks.
When tightening the flare nut with torque wrench,
ensure the direction for tightening follows the arrow
on the wrench.
Outside diameter
mm
6.35
9.52
12.7
15.88
19.05

inch
1/4
3/8
1/2
5/8
3/4

Torque
kgf.m
1.8~2.5
3.4~4.2
5.5~6.6
6.3~8.2
9.9~12.1

Outdoor unit
Liquid side piping
(Smaller diameter)

lbf.ft
13~18
24.6~30.4
39.8~47.7
45.6~59.3
71.6~87.5

Torque wrench
Gas side piping
(Bigger diameter)

117

Inverter Single

6RMI0-06A

Installation

Connecting the Cables


Indoor
Connect the cable to the indoor unit by connecting the wires to the terminals on the control board individually
according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit and the terminal No.
are the same as those of the indoor unit.)

The circuit diagram is a subject to change without notice.


The earth wire should be longer than the common wires.
When installing, refer to the circuit diagram on the chassis cover.
Connect the wires firmly so that they may not be pulled out easily.
Connect the wires according to color codes, referring to the wiring diagram.
Connect the wires should be sized per local code.

Main power source

For the circuit breaker between power source and the


outdoor units refer to specification pages.
Air
Conditioner

Circuit Breaker
Use a circuit breaker
or time delay fuse.

For the power cord connected to the outdoor units refer to specification pages (UL recognized or CAS
certified).
AWG_"A"

10

3m

Power supply cable (208/230V)


GN
/YL
20

mm

The power and transmission cable connected to the indoor and outdoor unit should be complied with the
following specifications (UL recognized or CAS certified).
AWG_"B"

Connecting cable (208/230V)

10

3m

Power
GN
/YL

"B"
20

Capacity(Btu/h)
9k/12k/16k/18k/24k/30k/36k
18

mm

h Field wiring shall be done such that the current carrying conductors become taut before the earthing conductor if the
cord slips out of the cord anchorage.

When using the separate wire as the power cord, please fix the separate wire into the control box panel by using
tie wrap as the fixture.

Inverter Single

118

Installation

6RMI0-06A

Outdoor
1. Remove the cover control from the unit by loosening
the screw.
Connect the wires to the terminals on the control board
individually as the following.
2. Secure the cable onto the control board with the holder
(clamper).
3. Refix the cover control to the original position with the
screw.

Terminal block
Over 5mm
(0.2")

Connecting
cable
Power
supply
cord

Conduit panel

Tubing cover

NOTICE
1. Separately wire power supply cord and connecting cable.
2. Use heat-proof electrical wiring capable of withstanding temperature up to 75C(167F).
3. Use outdoor and waterproof connection cable rated up to 300V for the connection between indoor and outdoor unit.
(For example, Type SJO-WA)

Be sure to comply with local codes while running the wire from the indoor unit to the outdoor unit(size of wire and
wiring method, etc).
Every wire must be connected firmly.
No wire should be allowed to touch refrigerant tubing, the compressor or any moving parts.

119

Inverter Single

6RMI0-06A

Installation

Wiring Diagram
ASUW093B1Y9(LSU091HSV2)
ASUW093BRM9(LAU090HSV2)
ASUW093FUB2(LAU090HVP)
ASUW093MMB8 (LAU090HYV)
ASUW093B1B8(LSU091HSV3)
ASUW123B1Y9(LSU121HSV2)
ASUW123BRM9(LAU120HSV2)
ASUW123FUB2(LAU120HVP)
ASUW123MMB8(LAU120HYV)
ASUW123B1B8(LSU121HSV3)
ASUW183CSA7(LSU180HEV)

ASUW183C2Y9(LSU181HSV2)
ASUW183CRM9(LAU180HSV2)
ASUW183C2B8(LSU181HSV3)
ASUW243DGY9(LSU240HSV2)
ASUW243CRM9(LAU240HSV2)
ASUW243D8B8(LSU240HSV3)

208/230 VAC

ASUW303DGY9(LSU307HV2)
ASUW303D8B8(LSU307HV3)
ASUW363DGY9(LSU360HV2)
ASUW363D8B8(LSU360HV3)

ASUW093MMM9(LSU090HYV)
ASUW123MMM9(LSU120HYV)

Inverter Single

120

Installation

ASUW093WSA7(LSU090HEV)
ASUW123BSA7(LSU120HEV)

121

6RMI0-06A

ASUW243CSA7(LSU240HEV)

Inverter Single

6RMI0-06A

Installation

How to connect wiring to the terminals

Power supply cable


Strand wire
Strip 10mm(3/8in)

n For strand wiring


(1) Cut the wire end with a wire cutter or wire-cutting
pliers, then strip the insulation to expose the strand
wiring about 10mm(3/8in).
(2) Using a screwdriver, remove the terminal screw(s) on
the terminal plate.
(3) Using a round terminal fastener or pliers, securely
clamp each stripped wire end with a round terminal.
(4) Position the round terminal wire, and replace and
tighten the terminal screw using a screwdriver.

Round
terminal

Connecting cable
Loosening the
terminal block
screw

Fastening the
wire tightly

Connecting cable

According to the confirmation of the above conditions, prepare the wiring as follows.
1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of
wiring, be guided by the circuit diagram posted on the inside of control cover.
2. The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from
vibrations to which the unit is subjected during the course of transportation. Check them and make sure
that they are all tightly fastened. (If they are loose, it could cause burn-out of the wires.)
3. Specification of power source.
4. Confirm that electrical capacity is sufficient.
5. See that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the
name plate.
6. Confirm that the cable thickness is as specified in the power source specification.
(Particularly note the relation between cable length and thickness.
7. Always install an earth leakage circuit breaker in a wet or moist area.
8. The following would be caused by voltage drop.
Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the normal
function of the overload.
9. The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an
air gap contact separation of at least 3mm in each active(phase) conductors.

Inverter Single

122

Installation

6RMI0-06A

Checking the Drainage


To check the drainage.
1. Pour a glass of water on the evaporator.
2. Ensure the water flows through the drain hose of the
indoor unit without any leakage and goes out the drain
exit.

Connecting area
drain hose

Leakage
checking
Drain pan

Drain
hose
Leakage
checking

Drain piping
1. The drain hose should point downward for easy drain
flow.

Downward slope

2. Do not make drain piping like the following.

Accumulated
drain water
Air

Do not raise

Water
leakage

123

Water
leakage

Waving

Tip of drain hose


dipped in water
Water
leakage

Inverter Single

Ditch

Less than
50mm gap

6RMI0-06A

Installation

Forming the Piping


In cases where the outdoor unit is
installed below the indoor unit perform
the following.
1. Tape the piping, drain hose and connecting cable from
down to up.

Seal the small


openings around
pipings with a gum
type sealants.
Connecting cable
(Conduit)
Saddle

Pipings

2. Secure the tapped piping along the exterior wall using


saddle or equivalent.
Taping
Drain hose

Trap is required to prevent water


from entering into electrical parts.

In cases where the Outdoor unit is


installed above the Indoor unit perform
the following.

Seal the small openings


around pipings with a
gum type sealants.

1. Tape the piping and connecting cable from down to


up.
2. Secure the taped piping along the exterior wall. Form a
trap to prevent water entering the room.

Trap

3. Fix the piping onto the wall using saddle or equivalent.

Trap

Inverter Single

124

Installation

6RMI0-06A

Air Purging
The air and moisture remaining in the refrigerant system have undesirable effects as indicated below.
1. Pressure in the system rises.
2. Operating current rises.
3. Cooling(or heating) efficiency drops.
4. Moisture in the refrigerant circuit may freeze and block capillary tubing.
5. Water may lead to corrosion of parts in the refrigeration system.
Therefore, after evacuating the system, take a leak test for the piping and tubing between the indoor and outdoor unit.

Air purging with vacuum pump


1. Preparation
Check that each tube(both liquid and gas side tubes) between the indoor and outdoor units have been properly
connected and all wiring for the test run has been completed. Remove the service valve caps from both the gas and
the liquid side on the outdoor unit. Note that both the liquid and the gas side service valves on the outdoor unit are
kept closed at this stage.

2. Leak test
Connect the manifold valve(with pressure gauges) and dry nitrogen gas cylinder to this service port with charge
hoses.

Be sure to use a manifold valve for air purging. If it is not available, use a stop valve for this purpose.
The knob of the 3-way valve must always be kept close.
- Pressurize the system to maximum 250 P.S.I.G. (R-22 model) or 400 P.S.I.G.
(R-410A model) with dry nitrogen gas and close the cylinder valve when the gauge reading reaches 250 P.S.I.G. (R22 model) or 400 P.S.I.G. (R-410A model). Next step is leak test with liquid soap.

To avoid nitrogen entering the refrigerant system in a


liquid state, the top of the cylinder must be higher than its
bottom when you pressurize the system. Usually, the
cylinder is used in a vertical standing position.
1. Do a leak test of all joints of the tubing(both indoor and
outdoor) and both gas and liquid side service valves.
Bubbles indicate a leak. Be sure to wipe off the test
solution with a clean cloth.
2. After the system is found to be free of leaks, relieve the
nitrogen pressure by loosening the charge hose
connector at the nitrogen cylinder. When the system
pressure is reduced to normal, disconnect the hose from
the cylinder.

125

Inverter Single

Indoor unit

Manifold valve
Pressure
gauge
Lo
Hi

Charge hose

Nitrogen gas
cylinder(in vertical
standing position)

Outdoor unit

6RMI0-06A

Installation

Soap water method


1. Remove the caps from the 2-way and 3-way valves.
2. Remove the service-port cap from the 3-way valve.
3. Apply a soap water or a liquid neutral detergent on the
indoor unit connection or outdoor unit connections by a
soft brush to check for leakage of the connecting points
of the piping.
4. If bubbles come out, the pipes have leakage.

Liquid side

Gas side
2-way valve
(Close)

Cap

Evacuation
1. Connect the charge hose end described in the preceding
steps to the vacuum pump to evacuate the tubing and
indoor unit.
Confirm the "Lo" knob of the pressure Gauge is open.
Then, run the vacuum pump.
The operation time for evacuation varies with tubing
length and capacity of the pump. The following table
shows the time required for evacuation.

3-way valve
(Close)

Indoor unit

Required time for evacuation when


30 gal/h vacuum pump is used
If tubing length is
If tubing length is
less than 10m (33 ft)
longer than 10m (33 ft)
10 min. or more
15 min. or more

2. When the desired vacuum is reached, close the knob of


the 3-way valve and stop the vacuum pump.

Finishing the Job


1. With a service valve wrench, turn the valve of liquid
side counter-clockwise to fully open the valve
2. Turn the valve of gas side counter clockwise to fully
open the valve
3. Loosen the charge hose connected to the gas side
service port slightly to release the pressure, then
remove the hose.
4. Replace the flare nut and its bonnet on the gas side
service port and fasten the flare nut securely with an
adjustable wrench. This process is very important to
prevent leakage from the system
5. Replace the valve caps at both gas and liquid side
service valves and fasten them tight.
This completes air purging with a vacuum pump.
6. Replace the pipe cover to the outdoor unit by one
screw.
Now the air conditioner is ready for test run.

Inverter Single

Outdoor unit
Manifold valve
Pressure
gauge

Lo

Hi

Open

Close

Vacuum pump

126

Installation

6RMI0-06A

Test Running
1. Check that all tubing and wiring are properly connected.
2. Check that the gas and liquid side service valves are fully open.

Prepare remote controller


1. Remove the battery cover by pulling it according to the
arrow direction.
2. Insert new batteries making sure that the (+) and () of
battery are installed correctly.
3. Reattach the cover by pushing it back into position.

NOTICE
Use 2 AAA(1.5volt) batteries. Do not use
rechargeable batteries.
Remove the batteries from the remote controller if the
system is not used for a long time.

127

Inverter Single

6RMI0-06A

Installation

Settlement of outdoor unit

Bolt

1. Fix the outdoor unit with a bolt and nut(10mm) tightly


and horizontally on a concrete or rigid mount.
2. When installing on the wall, roof or rooftop, anchor the
mounting base securely with a nail or wire assuming the
influence of wind and earthquake.
3. If the vibration of the unit is transmitted to the pipe,
secure the unit with an anti-vibration rubber.

Tubing connection

Evaluation of the performance

Return temperature

Operate the unit for 15~20 minutes, then check the system
refrigerant charge:
1. Measure the pressure of the gas side service valve.
2. Measure the air temperature from inlet and outlet of air
conditiioner.
3. Ensure the difference between the inlet and outlet
temperature is more than 8C(46.4F).
4. For reference; the gas side pressure at optimum
condition is shown on table (cooling)
The air conditioner is now ready to use.
ambient
Refrigerant Outside
TEMP.
R-410A 35C (95F)

Supply air

The pressure of the gas side

Supply
temperature

Return temperature
Supply air

8.5~9.5kg/cm2G(120~135 P.S.I.G.)

NOTICE
If the actual pressure is higher than shown, the system is
most likely over-charged, and charge should be removed.
If the actual pressure are lower than shown, the system is
most likely undercharged, and charge should be added.

Supply
temperature

Pump Down
This is performed when the unit is relocated or the refrigerant circuit is serviced.
Pump Down means collecting all refrigerant into the outdoor unit without the loss of refrigerant.

Be sure to perform Pump Down procedure in the cooling mode.

Pump Down Procedure


1. Connect a low-pressure gauge manifold hose to the charge port on the gas side service valve.
2. Open the gas side service valve halfway and purge the air in the manifold hose using the refrigerant.
3. Close the liquid side service valve(all the way).
4. Turn on the unit's operating switch and start the cooling operation.
5. When the low-pressure gauge reading becomes 1 to 0.5kg/cm2 G(14.2 to 7.1 P.S.I.G.), fully close the gas side
valve and then quickly turn off the unit. Now Pump Down procedure is completed, and all refrigerant is collected into
the outdoor unit.

Inverter Single

128

Installation

6RMI0-06A

Installation Guide for Areas Exposed to Sea Wind

CAUTION
1. Air conditioners should not be installed in areas where corrosive gases, such as acid or alkaline gas, are produced.
2. Do not install the product where it could be exposed to sea wind (salty wind) directly. It can result corrosion on the
product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient
performance.
3. If outdoor unit is installed close to the seaside, it should avoid direct exposure to the sea wind. Otherwise it needs
additional anticorrosion treatment on the heat exchanger.

Selecting the location(Outdoor Unit)


1) If the outdoor unit is to be installed close to the seaside, direct exposure to the sea wind should be avoided. Install the
outdoor unit on the opposite side of the sea wind direction.

Sea wind
Sea wind

2) In case, to install the outdoor unit on the seaside, set up a windbreak not to be exposed to the sea wind.

Windbreak

Sea wind

- It should be strong enough like concrete to prevent the


sea wind from the sea.
- The height and width should be more than 150% of the
outdoor unit.
- Keep more than 70 cm of space between outdoor unit
and the windbreak for easy air flow.

3) Select a well-drained place.


1. If you cant meet above guide line in the seaside installation, please contact LG Electronics for the additional
anticorrosion.
2. Periodic ( more than once/year ) cleaning of the dust or salt particles stuck on the heat exchanger by using
water.
* Do not use seawater you clean up the heat exchanger

129

Inverter Single

P/No.: 3828A20892Z

Air Conditioner
20 Yeouido-dong, Yeongdeungpo-gu,
Yeouido P.O.Box 335 Seoul,
150-721, Korea.
http://www.lgeaircon.com

All rights reserved


Printed in Korea August / 2013
The specifications, designs, and
information in this brochure are subject to
change without notice.

The air conditioners manufactured by LG have received ISO9001 certificate for


quality assurance and ISO14001 certificate for environmental management system.

You might also like