You are on page 1of 6

i1-1

Exicon


Multi-Function Power Meter

Design Features Model DM2436AB
16 bits CPU
True RMS measurement
Resistant to external noise
RS232/RS485 Modbus output
PT and CT scaling
Memory for all setup and energy data
Relay output (V or A or W)
Auto calibration
Maximum and Minimum function


The DM2436AB is a micro-processor based power meter using 16 bits CPU, it provides digital
measuring, indicating, calibrating and output functions. The DM2436AB replaces several static
converters and measuring devices (V, A, W, VAR, PF, WH, VARH, Hz), and provides special
functions such as Maximum measuring, Minimum measuring and comparison output. It has
RS232 or RS485 output using standard Modbus communication protocol.
E
x
c
e
l
l
e
n
c
e

i
n

C
o
n
t
r
o
l


Indicating
L1 (R) L 2 (S) L 3 (T)
Line
Voltage
Total
VTRMS V1 (L1 N) V2 (L2 N) V3 (L3 N) V12,V23,V13 V ()
ATRMS A1 A2 A3 A ()
W W(CH1) W(CH2) W(CH3) W()
VAR VAR(CH1) VAR(CH2) VAR(CH3) VAR()
PF PF(CH1) PF(CH2) PF(CH3) PF()
WH WH(CH1) WH(CH2) WH(CH3) WH()
VARH VARH(CH1) VARH(CH2) VARH(CH3) VARH()
Items
Hz Hz(CH1) Hz(CH2) Hz(CH3) Hz()
D
i
g
i
t
a
l

p
o
w
e
r

m
e
t
e
r


i1-2

Exicon


E
x
c
e
l
l
e
n
c
e

i
n

C
o
n
t
r
o
l


Communication

RS-232C
The RS-232C connection allows one single point-to-point communication connection using
standard RS-232C communication cable with a maximum length of 50 feet long (15.2m).

RS-485
RS-485 communication allows multiple devices connect on the same bus. Up to 30 devices can be
connected on one RS-485 bus using a shielded twisted pair cable. The overall length of RS-485
cable cannot exceed 4000 ft (1219m).






Comparison Output
The DM2436AB has two comparison outputs. User can set two input values of voltage. Current or
wattage. When actual input value exceeds pre-set value. Output changes status.








T1: H1 Relay ON
T2: H2 Relay ON


D
i
g
i
t
a
l

p
o
w
e
r

m
e
t
e
r



i1-3

Exicon


Specification
Reading Range
Display 4 digits (9999), 0.4" high (V, A, W, VAR, PF, Hz)
5 digits (99999), 0.4" high (WH, VarH)
Accuracy (at 235 sine wave)
Voltage 0.1% 0.15%
Current 0.1% 0.15%
Watt 0.2% 0.3%
Var 0.2% 0.3%
Power factor 0.5%
PF polarity "+" lagging, "-" leading
Watt hour 0.25% 1 Count
Var hour 0.4% 1 Count
Hz 0.2%
Max. input over capability 10A Continuous, 50A for 5 Sec, Volt.750V continuous
Conversion rate Approx 1/Sec
Over input indication "OL"
Line voltage range 35V ~ 600V
Phase voltage range 20V ~ 346V
Current range 50mA ~ 5A
Power factor range 0.5 ~ 1
Frequency range 45 ~ 65Hz
CT, PT scaling factors 1 ~ 9999
Setting for REF 0.800 ~ 1.200
Operating temp. 0 ~ 60
Storage temp. -10 ~ 70
Temp. coefficient 100PPM/ ( 60PPM/ , 25 10 ) Q Q
Max. relative humidity 95%
Dielectric strength AC 2KV / 1min. (input / output / power)
AC2.8KV/1min.(input/output/power / case)
Surge test 4KV / 1.2 X 50S, IEC 255-4
Dimensions 110(W) X 110(H) X 135(D) mm
Mounting Panel mounting
Protocol MODBUS, RTU
Baud rate 9600
Address range 1 ~ FF (Hex)
Watt-hour data back-up time 1000 Hours
Aux. power AC90 ~ 260V,50/60Hz DC24V,48V, 110V20% (option)
Power consumption AC6VA, DC5W
Weight Approx 700g
E
x
c
e
l
l
e
n
c
e

i
n

C
o
n
t
r
o
l

Due to ongoing research and product improvement, specifications are subject to change without notice.
D
i
g
i
t
a
l

p
o
w
e
r

m
e
t
e
r



i1-4

Exicon


E
x
c
e
l
l
e
n
c
e

i
n

C
o
n
t
r
o
l


Wiring Diagrams
Output terminal











RS-232 / RS-485








D
i
g
i
t
a
l

p
o
w
e
r

m
e
t
e
r



i1-5

Exicon


E
x
c
e
l
l
e
n
c
e

i
n

C
o
n
t
r
o
l


Input Wiring

A. 3 Phase 3 wires with 2CTs. 2PTs








B. 3 Phase 3 wires with 3 CTs 2PTs








C. 3 Phase 4 wires with 3CTs. 3PTs









D. 1 Phase 2 wires with 1CTs. No PT



D
i
g
i
t
a
l

p
o
w
e
r

m
e
t
e
r



i1-6

Exicon


Dimensions Panel Cut-Out












Order Information














E
x
c
e
l
l
e
n
c
e

i
n

C
o
n
t
r
o
l

DM2436AB-2003-7-19
D
i
g
i
t
a
l

p
o
w
e
r

m
e
t
e
r


Locally Distributed By