You are on page 1of 4

Fresh Air Ready For You

EcoAir series
Range of capacity from
800-6000m3
OHRU - C (compact)
Heat Recovery Units
To reduce the CO2 emission in the air
To recover the energy for heating and cooling
To remove or decrease the odors
To remove contaminants from the air
-
-
-
-
- To live healthier lives
- To save energy
Filter G3
Filter G3
Heat Recovery
Exhanger
Exhaust Air fan
SIDE PANELS
Fresh Air
Fresh Air Supply fan
Exhaust Air
N
E
W

E
D
I
T
I
O
N
E
C
O
N
O
M
I
C

U
N
I
T
OzonAir - Quick selection guide
OHRU-1000-B0N-EU4-IV-01-EH-BP-SS-f-DC
Heat Recovery
unit
Type:
2000
3000
4000
5000
Optional inner skin:
IV indoor vertical unit
IH indoor horizontal unit
OV outdoor vertical unit
OH outdoor horizontal unit
EH-electric heater
Placing an order
OzonAir
brand
1000
Air filter:
G3, EU4, EU5, EU6..
0-round duct connection
By-Pass
Optional:
DX direct expansion coil - HEAT PUMP -
WE water heating coil -
CE water cooling coil -
SS-stainless steel
EC-epoxy coating
1-square duct connection 1
First number:
Second number: side configuration of duct connections
Optional flexible duct connection:
NC - no controller
SC - standard controller
DC - digital controller
Type of mounting
Optional controller: In todays living ventilation and better indoor
air quality (IAQ) is not a luxury anymore, but need.
Fresh and clean air is crucial for good mental
and physical condition for the people. With fresh
and clean air in the buildings kids can be more
happier, students can think and learn faster,
EcoAir OHRU series of products are designed for fresh air.
But, they can during this process. SAVE ENERGY
All 5 sizes of OHRU incorporate EUROVENT certified aluminum plate heat
recuperators. The efficiencies vary for each size, but will be approximately
within the ranges from 50%to 70%. Efficiencies may rise up to 80% for high
temperature and humid applications such as swimming pools, changing rooms
or similar. Recuperators are available with epoxy coating for coastal and
HEAT RECUPERATOR
ELECTRIC HEATER, WATER COIL OR DIRECT EXPANSION COIL AT HEATING / COOLING (OPTION)
In order to achieve best IAQ, heating and/or cooling coils are available as per order.
There are several options available including electric heater or pre-heating, water coil for heating and
cooling as well newest design with integrated DX coils for cooling only or heat pump (reversible).
Values referring to the following conditions: Tout. air.=-15C; Tin=20C; R.H.in = 50%; Nominal airflow
workers can be more productive and all people
can live healthier lives. Fresh air keep our health.
swimming pool applications.
BYPASS DAMPER (OPTION)
A Bypass Damper can be fitted inside the unit in order to bypass the supply air. The damper
is option with a 240 volts on/off actuator (24 volts option) for summer or winter control.
Further controls are available for the damper to provide free cooling.
B0 - Without profiles
N - Tip of isolation
Thermal recovery
unit for OHRU
1000 2000 3000 4000 6000
Ef f iciency - % 51,1 51,2 50,2 55,0 54,3
Recovery thermal
power kW
6,1 12,0 17,6 25,8 38,2
Renewal air outlet
temperature C
6,2 6,4 6,7 5,6 5,7
OHRU Technical Data For The Recovery Unit
All fans are direct drive powered and specially selected for efficient operation. All of the fans
used for the OHRU series are ideal for speed regulation and a full range of matched speed
controllers are available.On all models, fans are wired to externally mounted isolators.
Fan motors are totally enclosed and suitable for speed control. All fans are with built in
anti-vibration mountings, but in accordance with best practice, we still recommend the use
of anti vibration mounts and flexible connections.
Panels are 1 mm thickness with internal acoustic/thermal mineral fiber insulation.
The skin is made of galvanized sheet metal.
Standard supply and exhaust air filters are EU4 (G4) grade according to EN 779 disposable
pleated panel. Manometers are available as an option. Higher efficiency filters EU5, EU6 or
other are available as option also.
FANS
MOTORS
PANELS
FILTERS
PLUG AND PLAY INSTALLATION
All OHRU units are specifically designed so even instal out knowledge and skills can
change and rotated connections for inlet or exhaust in every possible direction with simple
operation. One side changing can take approximately 5min. For any special request or
connections please discuss with our . possibility engineers
ON SITE CHANGING OF CONNECTION SIDES
ler with
CONTROL PANEL
MANUAL BASE UNIT CONTROLER
OHRU units can be simply controlled with manual controller. It controls on/off function of the
unit in base version.
ELECTRIC OR/AND WATER HEATER CONTROLLER (HEATING AND/OR COOLING)
OHRU units can be alternatively controlled with digital upgrade controller. It controls on/off
functions, fan speed, IAQ, by-pas actuator, three-way motorized valve, filter static pressure,
timer and other functions.
OHRU - Dimensions
OZONdooel,VarsavskaNr.1,1000Skopje,Macedonia
Tell/fax:+389(2)3091212/3091211
e-mail:info@ozon.com.mk
www.ozon.com.mk
OzonAir OHRU Dimensions
OHRU L B H C D E G I K M N
Duct Connection
Weight
Round Square
1000 1020 455 860 232 208 99 300 300 65 124 78 350 300x300 85
2000 1200 526 940 232 262 119 350 350 60 132 88 400 350x350 110
3000 1375 610 1075 332 290 103 400 400 69 160 105 450 400x400 140
4000 1475 675 1115 331 294 113 500 500 29 191 88 550 500x500 170
6000 1675 807 1400 373 404 164 600 600 50 202 104 610 600x600 250

You might also like