Alcatel-Lucent

WiMAX
9740 WAC Cabinet Configuration
and Engineering Rules
WAN Document
Engineering Document
Release W3 from MR1
3BK 21591 AAAA PGZZA Ed.12
Status RELEASED
Short title wanconf
All rights reserved. Passing on and copying of this document, use
and communication of its contents not permitted without written
authorization from Alcatel-Lucent.
BLANK PAGE BREAK
2 / 36 3BK 21591 AAAA PGZZA Ed.12
Contents
Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.1 Applicable Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.2 9740 WAC Cluster Basic Hardware Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.3 9740 WAC Basic Software Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2 Generic Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.1 HW Configurations for Pure 9740 WAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.2 CN Hardware Configurations for Colocalized Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.2.1 CN NEs in Colocalized Configurations and Equipment Supported . . . . . . . . . . . 14
2.2.2 9740 WAC NEs in Colocalized Configurations and Equipment Supported . . . . 15
3 Engineering Rules for WR02 Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.1 Technical Mnemonics and Management on Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.1.1 9740 WAC Mnemonics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.1.2 Mechanical Mnemonics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.2 WR02 Rack HW Configuration of Pure 9740 WAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.2.1 WAC-1000 to WAC-2000 Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.2.2 WAC-2000 to WAC-4000 Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.2.3 WAC-4000 to WAC-6000 Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.2.4 WAC-6000 to WAC-10000 Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.3 Installation Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
3.4 SW Configuration for Pure 9740 WAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
3.5 External Connections Overview for Pure 9740 WAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3.5.1 Port Assignment on 9740 WAC Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
3.5.1.1 Wiring Attached to Ethernet Links with RAN and CN . . . . . . . . . . . 26
3.5.1.2 Wiring Attached to Ethernet Links with Other Devices . . . . . . . . . . 27
3.5.2 9740 WAC Rack to O&M Networks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4 Engineering Rules for WR03 Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
4.1 Technical Mnemonics and Management on Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
4.2 Mechanical Mnemonics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
4.3 Colocalized 9740 WAC-CN Rack WR03 HW Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
4.4 WAC-1000 to WAC-2000 Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
4.5 CN SW Configuration for Colocalized Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
4.6 Colocalized 9740 WAC-CN Rack WR03 Changed in Pure 9740 WAC Rack WR02 . . . . . . . 34
4.7 External Connections Overview for Colocalized 9740 WAC-CN Rack . . . . . . . . . . . . . . . . . . . 34
4.7.1 Port Assignment on CN Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
4.7.2 9740 WAC Rack to O&M Networks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
3BK 21591 AAAA PGZZA Ed.12 3 / 36
Figures
Figures
Figure 1: General Hardware Architecture of the 9740 WAC Cluster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 2: General Platform Software Overview of the 9740 WAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 3: WR02 Rack Layout and Unit Numbering for Pure 9740 WAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 4: WAC-1000 to WAC-2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 5: WAC-2000 to WAC-4000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 6: WAC-4000 to WAC-6000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 7: WAC-6000 to WAC-10000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 8: Connections Outside of Pure 9740 WAC Rack (for 1 Cluster, Max. Configuration) . . . . . . . . . . . . . 25
Figure 9: Wiring Attached to Ethernet Links Between Pure 9740 WAC and CN NEs . . . . . . . . . . . . . . . . . . . 26
Figure 10: Port Assignment for LMT and Console for Ethernet Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Figure 11: WR03 Rack Layout and Unit Numbering for 9740 WAC Colocalized Architecture . . . . . . . . . . . . 31
Figure 12: WAC-1000 to WAC-2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 13: Connections Overview Outside of CN Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 14: Wiring Attached to Ethernet Links with RAN and CN According to Configurations . . . . . . . . . . . . 35
Figure 15: Port Assignment for LMT and Console Ethernet Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
4 / 36 3BK 21591 AAAA PGZZA Ed.12
Tables
Tables
Table 1: Applicable Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Table 2: WAC Configurations for Pure 9740 WAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Table 3: CN Configurations for 9740 WAC Colocalized Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Table 4: W3MR1 Field Trial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table 5: 9740 WAC Mnemonics and Technical Management on Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Table 6: Mechanical Mnemonics and Technical Management on Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Table 7: SW Configuration for Pure 9740 WAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Table 8: Mnemonics and Technical Management for CN Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Table 9: SW Configuration for 9740 WAC Colocalized Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3BK 21591 AAAA PGZZA Ed.12 5 / 36
Tables
6 / 36 3BK 21591 AAAA PGZZA Ed.12
Preface
Preface
Purpose This document describes the engineering rules used to build the WAC cabinet
generic configurations commonly called "9740 WAC" for WiMAX releases
W3MR1.
The following naming conventions are used in this document:
The Alcatel-Lucent 9740 WiMAX Access Controller will be later referred
as 9740 WAC, (former A9160 WAC)
The Alcatel-Lucent 9710 Compact WiMAX Base Station will be later
referred as 9710 C-WBS, (former A9116 WiMAX BS)
The Alcatel-Lucent 9753 WiMAX Operation and Maintenance Center will
be later referred as 9753 OMC, (former A1353WR OMC-R)
The WiMAX Access Control Server will be later referred as WAC.
The 9710 C-WBS refers also to 9715 Light WiMAX Base Station 9715 L-WBS,
(former A9117 L-WBS).
Whats New In Edition 12
Dell vIII introduction in the document.
In Edition 11
The section 9740 WAC Cluster Basic Hardware Architecture (Section 1.2) is
updated.
In Edition 10
First official release of document.
Audience This manual is for people requiring an in-depth understanding of the
configuration rules of the Alcatel-Lucent WAC:
Network decision makers who require an understanding of the underlying
functions and rules of the system including:
Network planners
Technical design staff
3BK 21591 AAAA PGZZA Ed.12 7 / 36
Preface
Trainers.
Operations and support staff who need to know how the system operates in
normal conditions including:
Operators
Support engineers
Maintenance staff
Client Help Desk personnel.
This document can interest also the following teams:
Quality Acceptance First-Off
Cellular Operations
Technical Project Managers
Validation
Methods.
Assumed Knowledge The document assumes that the reader has an understanding of:
WiMAX System
Mobile telecommunications.
8 / 36 3BK 21591 AAAA PGZZA Ed.12
1 Introduction
1 Introduction
This document describes the authorized hardware and software configurations
for the 9740 WiMAX WAC for RAN and CN in WiMAX release W3MR1.
3BK 21591 AAAA PGZZA Ed.12 9 / 36
1 Introduction
1.1 Applicable Documents
Item Reference
9740 WAC Cabinet Description 3BK21509AAAATQZZA
9740 WAC Cabinet Installation Manual 3BK174350091RJZZA
9740 WAC Cabinet Service Reference Sheet 3BK174350099RJZZA
Table 1: Applicable Documents
1.2 9740 WAC Cluster Basic Hardware Architecture
9740 WAC architecture is mainly based on cluster concept. WAC server linked
together and to same assembly of switches constitute a "WAC cluster".
Figure 1: General Hardware Architecture of the 9740 WAC Cluster
Note: For redundancy, WAC server have in fact Ethernet links connected to different
switches.
The Figure 1 shows the general architecture with redundancy links.
Without redundancy only one link of WAC is connected to each part of the
corresponding switch:
One link to WAC switch for 9710 C-WBS on the left side
One link to WAC switch for CN on the right side.
Note: For details regarding the HW used in this configurations see 9740 WAC
Cabinet Description.
10 / 36 3BK 21591 AAAA PGZZA Ed.12
1 Introduction
A WAC Cluster as a whole is made of WAC Servers and WAC Switches.
Switches in a standalone or a stack configuration, with regard to the Cluster
Configuration, are configured by the WAC Servers in a WAC Cluster. A WAC
Switch cannot be shared by 2 WAC Clusters or by any other equipment. All the
Switch ports are used and designed for a specific behavior as described in
the relevant documentation. Moreover, it is forbidden to launch on the WAC
Server any SW Application for which this equipment is not designed. Only HW
configurations defined in the relevant documentation are authorized.
3BK 21591 AAAA PGZZA Ed.12 11 / 36
1 Introduction
1.3 9740 WAC Basic Software Architecture
Figure 2: General Platform Software Overview of the 9740 WAC
The 9740 WAC Platform software internal structure covers the following parts:
OS Service Daemons The existing OS services that WAC can rely on.
They include:
HTTP server with security
SFTP server
SNMP daemon with security
SSH2 daemon in WAC.
Common Platform Service It defines the common service interfaces for
the upper layer 9740 WAC applications.
It covers the:
Buffer management
Timer management
Trace management
Inter-process communication management, etc.
The common service is provided as a library for the 9740 WAC application.
Equipment Management It is used to supply the WAC hardware
(DELL Servers) supervision and directs the hardware alarm notification to
the OAM-FM.
The OS Service Daemons covers the service provided by the OS (Linux).
They include the HTTP server with security, SFTP daemon, SSH2 daemon
and SNMP daemon (SNMP Master Agent daemon for WAC DELL Server HW
management). It is implemented by Net-SNMP v5.1.2 (included in RedHat
Linux ES4).
12 / 36 3BK 21591 AAAA PGZZA Ed.12
2 Generic Configurations
2 Generic Configurations
This section defines the basis of the minimum configurations needed for
Alcatel-Lucent catalogue solutions on "9740 WiMAX WAC Cabinet".
3BK 21591 AAAA PGZZA Ed.12 13 / 36
2 Generic Configurations
2.1 HW Configurations for Pure 9740 WAC
The generic configurations based on WAC PE1950 and Switch OS6850-24X
for new networks are shown in the following table.
Configuration Capacity Active WAC Redundant
WAC
Switch High
Availability
WAC-1000 1 Gbs 1 0 1 No
WAC-2000 2 Gbs 2 1 2 Yes
WAC-4000 4 Gbs 4 1 2 Yes
WAC-6000 6 Gbs 6 1 3 Yes
WAC-10000 10 Gbs 10 2 3 Yes
Table 2: WAC Configurations for Pure 9740 WAC
Note: Configuration WAC-1000 without redundancy and WAC2000 can be housed
in a WR03 rack with CN elements.
2.2 CN Hardware Configurations for Colocalized Configurations
The following tables show configurations for new field trial.
2.2.1 CN NEs in Colocalized Configurations and Equipment Supported
The following table gives the equipment for different field trial configurations in
W3MR1.
Auxiliary
Switch
Home Agent DHCP Server AAA Server SBC CN
Configuration
H4 F1 S1 G1 E1
Quantity 1 1
optional
1
optional
1
optional
1
optional
W3MR1 field
trial
OS685024X
OS680024
CISCO 3845 Dell PE-1950
Dell PE-1850
Dell PE-1950 Dell PE-1950
25 sessions
Table 3: CN Configurations for 9740 WAC Colocalized Architecture
14 / 36 3BK 21591 AAAA PGZZA Ed.12
2 Generic Configurations
2.2.2 9740 WAC NEs in Colocalized Configurations and Equipment
Supported
The following table gives 9740 WAC configurations in W3MR1 and the type of
equipment supported for new field trial.
Active WAC Redundant
WAC
Switch Configuration Capacity
V1, V2 V3 H1, H2
High
Availability
WAC500 0.5Gbps 1
PE-1850
0 1
OS680024
No
WAC-1000 1Gbps 1
PE-1950
0 1
OS685024X
No
WAC-2000 2Gbps 2
PE-1950
1
PE-1950
2
OS685024X
Yes
Table 4: W3MR1 Field Trial
3BK 21591 AAAA PGZZA Ed.12 15 / 36
2 Generic Configurations
16 / 36 3BK 21591 AAAA PGZZA Ed.12
3 Engineering Rules for WR02 Rack
3 Engineering Rules for WR02 Rack
This section describes engineering rules for the WR02 rack system
configurations.
3BK 21591 AAAA PGZZA Ed.12 17 / 36
3 Engineering Rules for WR02 Rack
3.1 Technical Mnemonics and Management on Modules
3.1.1 9740 WAC Mnemonics
Short Designation Description Alcatel-Lucent
mnemonic
Supplier acronym
V1 DELL PE-1950 SERVER or
DELL PE-1850 SERVER
PVSER407
PVSER400
PE-1950
PE-1850
V2 to V12 DELL PE-1950 SERVER PVSER407 PE-1950
V3 DELL PE-1950 SERVER vIII PVSER409 PE-1950
H1 OMNISWITCH 6850-24X or
OMNISWITCH 6800-24
PVSWI04
PVSWE04
OS6850-24x
OS6800-24
H2 and H3 OMNISWITCH 6850-24X PVSWI04 OS6850-24x
None 1000BASE-SX MiniGBIC PVSWEA10 SFP GIG SX
None 1000BASE-LX MiniGBIC PVSWEA11 SFP GIG LX
None 10000BASE-SR GBIC PVSWEA09 XFP 10G SR
None 10000BASE-LR GBIC PVSWEA13 XFP 10G LR
None POWER SUPPLY PE-1850 PVSERA01 None
None POWER SUPPLY PE-1950 vII PVSERA03 None
None POWER SUPPLY PE-1950 vIII PVSERA06 None
None HDD 73 GO SCSI U320 PVSERD03 None
None HDD 146 GO SCSI U320 PVSERD04 None
None POWER SUPPLY OS685024X PVSERA04 None
Table 5: 9740 WAC Mnemonics and Technical Management on Modules
3.1.2 Mechanical Mnemonics
Short Designation Description Alcatel-Lucent mnemonic
Rack Basic Rack 24U JRN24U
Pstrip Power strip 2 x 3 Outlets ID2SU
PDU Power Distribution Unit ID3X16
Table 6: Mechanical Mnemonics and Technical Management on Modules
18 / 36 3BK 21591 AAAA PGZZA Ed.12
3 Engineering Rules for WR02 Rack
3.2 WR02 Rack HW Configuration of Pure 9740 WAC
The following figure shows WR02 Rack layout for 9740 WAC. It gives Unit
positions and numbering in rack.
Figure 3: WR02 Rack Layout and Unit Numbering for Pure 9740 WAC
Note: WAC500 configuration is based on PE1850 and OS680024.
WAC500 and WAC1000 are without redundancy.
3BK 21591 AAAA PGZZA Ed.12 19 / 36
3 Engineering Rules for WR02 Rack
3.2.1 WAC-1000 to WAC-2000 Extension
Note: This is done with HW change using:
2xSU kit V2, V3
1xXU kit H2
2 stacking cables.
Figure 4: WAC-1000 to WAC-2000
Note: For details see 9740 WAC Cabinet Installation Manual, WAC1000 to
WAC-2000.
20 / 36 3BK 21591 AAAA PGZZA Ed.12
3 Engineering Rules for WR02 Rack
3.2.2 WAC-2000 to WAC-4000 Extension
Note: This is done with HW change using 2xSU kit V4 and V5.
Figure 5: WAC-2000 to WAC-4000
Note: For details see 9740 WAC Cabinet Installation Manual, WAC2000 to
WAC-4000.
3BK 21591 AAAA PGZZA Ed.12 21 / 36
3 Engineering Rules for WR02 Rack
3.2.3 WAC-4000 to WAC-6000 Extension
Note: This is done with HW change using:
2xSU kit V6 and V7
1xXU kit H3
1x stacking cable.
Figure 6: WAC-4000 to WAC-6000
Note: For details see 9740 WAC Cabinet Installation Manual, WAC4000 to
WAC-6000.
22 / 36 3BK 21591 AAAA PGZZA Ed.12
3 Engineering Rules for WR02 Rack
3.2.4 WAC-6000 to WAC-10000 Extension
Note: This is done with HW change using:
5xSU kit V8, V9, V10, V11 and V12
Cables kit contains 20 ALETHDP Ethernet cables.
Figure 7: WAC-6000 to WAC-10000
Note: For details see 9740 WAC Cabinet Installation Manual, WAC6000 to
WAC-10000.
3BK 21591 AAAA PGZZA Ed.12 23 / 36
3 Engineering Rules for WR02 Rack
3.3 Installation Kits
Engineering rules principle for installation kits:
Basic install kit 1 per WR02 or WR03 rack
Power supply cables Relevant to distance between rack power supply
and 9740 WAC configuration and to breakers range.
Ethernet cables Relevant to:
Distance between External equipment and 9740 WAC configuration
Electrical or optical technology
Configurations.
Options relevant to customer site.
3.4 SW Configuration for Pure 9740 WAC
Name /
Reference
SW Item /
Function
Alcatel-Lucent
Mnemonic
Version Provider Unit No.
RED HAT
ENTERPRISE
LINUX
(RHEL4)
Operating
System
PVLS601 2.6.9-42
elsmp update
4
Red Hat WAC vII 1 per WAC
RED HAT
ENTERPRISE
LINUX
(RHEL4)
Operating
System
PVLS601 2.6.9-42
elsmp update
6
Red Hat WAC vIII 1 per WAC
Table 7: SW Configuration for Pure 9740 WAC
24 / 36 3BK 21591 AAAA PGZZA Ed.12
3 Engineering Rules for WR02 Rack
3.5 External Connections Overview for Pure 9740 WAC
Figure 8: Connections Outside of Pure 9740 WAC Rack (for 1 Cluster, Max. Configuration)
Note: Console for switch and LMT and their cables are not included in 9740 WAC
configurations.
3BK 21591 AAAA PGZZA Ed.12 25 / 36
3 Engineering Rules for WR02 Rack
3.5.1 Port Assignment on 9740 WAC Configurations
3.5.1.1 Wiring Attached to Ethernet Links with RAN and CN
Figure 9: Wiring Attached to Ethernet Links Between Pure 9740 WAC and CN NEs
Note: For Ethernet port names see 9740 WAC Cabinet Description.
There is also a configuration named WAC-500. This configuration is used
only in the Field Trial case.
26 / 36 3BK 21591 AAAA PGZZA Ed.12
3 Engineering Rules for WR02 Rack
3.5.1.2 Wiring Attached to Ethernet Links with Other Devices
Figure 10: Port Assignment for LMT and Console for Ethernet Connections
Note: For Ethernet port names see 9740 WAC Cabinet Description.
3.5.2 9740 WAC Rack to O&M Networks
The 9753 OMC has an interface with all WAC of the cluster (active and backup)
but there is no direct link to the 9753 OMC from WR02 rack. O&M data flow is
included in RAN link to external equipment.
3BK 21591 AAAA PGZZA Ed.12 27 / 36
3 Engineering Rules for WR02 Rack
28 / 36 3BK 21591 AAAA PGZZA Ed.12
4 Engineering Rules for WR03 Rack
4 Engineering Rules for WR03 Rack
This section describes engineering rules for the WR03 rack system
configurations.
3BK 21591 AAAA PGZZA Ed.12 29 / 36
4 Engineering Rules for WR03 Rack
4.1 Technical Mnemonics and Management on Modules
The following table gives, for different colocalized configurations in W3MR1:
Technical mnemonics and management on modules
Type of equipment supported for new field trial.
Short
Designation
Description Alcatel-Lucent
mnemonic
Supplier acronym
S1
(DHCP)
DELL PE-1950 SERVER vI or vII
DELL PE-1950 SERVER vIII
DELL PE-1850 SERVER
PVSER407
PVSER409
PVSER400
PE-1950 vI or vII
PE-1950 vIII
PE-1850
H4
(Auxiliary
Switch)
OMNISWITCH 6850-24X or
OMNISWITCH 6800-24
PVSWI04
PVSWE04
OS6850-24X
OS6800-24
F1
(HA)
CISCO 3845 ROUTER PVRT01 -
G1
(AAA)
DELL PE-1950 SERVER vI or vII
DELL PE-1950 SERVER vIII
PVSER407
PVSER409
PE-1950 vI or vII
PE-1950 vIII
E1
(SBC)
DELL PE-1950 SERVER vI or vII
DELL PE-1950 SERVER vIII
PVSER407
PVSER409
PE-1950 vI or vII
PE-1950 vIII
Table 8: Mnemonics and Technical Management for CN Modules
Note: The Home Agent (F1), DHCP server (S1) and AAA server (G1) are optional.
SBC (E1) is optional.
4.2 Mechanical Mnemonics
See Table 6 in Section Mechanical Mnemonics (Section 3.1.2) for pure 9740
WAC rack WR02.
30 / 36 3BK 21591 AAAA PGZZA Ed.12
4 Engineering Rules for WR03 Rack
4.3 Colocalized 9740 WAC-CN Rack WR03 HW Configuration
The following table shows WR03 rack layout for new field trial. It gives unit
positions and numbering in rack.
Figure 11: WR03 Rack Layout and Unit Numbering for 9740 WAC Colocalized Architecture
Note: This layout is applicable for W3MR1 new colocalized configurations.
3BK 21591 AAAA PGZZA Ed.12 31 / 36
4 Engineering Rules for WR03 Rack
4.4 WAC-1000 to WAC-2000 Extension
Note: This is done with HW change using:
2xSU kit V2 and V3
1xXU kit H2
2x stacking cables.
Figure 12: WAC-1000 to WAC-2000
Note: For details see 9740 WAC Cabinet Installation Manual, WAC-1000 to
WAC-2000.
32 / 36 3BK 21591 AAAA PGZZA Ed.12
4 Engineering Rules for WR03 Rack
4.5 CN SW Configuration for Colocalized Architecture
Name /
Reference
SW Item /
Function
Alcatel-Lucent
Mnemonic
Version Provider Unit No. / Unit
RED HAT
ENTERPRISE
LINUX
(RHEL4)
Operating
System
PVLS601 2.6.9-42
elsmp update
4
Red Hat WAC
DHCP
server, SBC
and AAA
1 per server
RED HAT
ENTERPRISE
LINUX
(RHEL4)
Operating
System
PVLS601 2.6.9-42
elsmp update
6
Red Hat WAC
DHCP
server, SBC
and AAA
1 per server
Vital-AAA AAA SW None Vital AAA-BP
V5.2.1
Lucent
Technologies
AAA server 1 per server
NEOXBC LIC.
/ 25 CALLS
BASE
SBC SW PVLS628 NeoXBC
v4.6.1-Eq
build002
Neotip
Converse
SBC
controler
1 per
controler
Table 9: SW Configuration for 9740 WAC Colocalized Architecture
3BK 21591 AAAA PGZZA Ed.12 33 / 36
4 Engineering Rules for WR03 Rack
4.6 Colocalized 9740 WAC-CN Rack WR03 Changed in Pure
9740 WAC Rack WR02
This section gives information about engineering rules when a colocalized
9740 WAC-CN configuration is dismantled to become a pure 9740 WAC rack
configuration for commercial operation.
Initial WR03 rack configuration CN elements are dismantled, HW
configuration of WR02 rack described in Section WR02 Rack HW Configuration
of Pure 9740 WAC (Section 3.2) is applied and configuration is changed in
WR02 9740 WAC rack configuration.
4.7 External Connections Overview for Colocalized 9740
WAC-CN Rack
Figure 13: Connections Overview Outside of CN Rack
34 / 36 3BK 21591 AAAA PGZZA Ed.12
4 Engineering Rules for WR03 Rack
4.7.1 Port Assignment on CN Configurations
Figure 14: Wiring Attached to Ethernet Links with RAN and CN According to Configurations
Figure 15: Port Assignment for LMT and Console Ethernet Connections
Note: For Ethernet port names see 9740 WAC Cabinet Description.
4.7.2 9740 WAC Rack to O&M Networks
The 9753 OMC has an interface with all WAC of the cluster (active and backup)
but there is no direct link to the 9753 OMC from WR02 rack. O&M data flow is
included in RAN link to external equipment.
3BK 21591 AAAA PGZZA Ed.12 35 / 36
4 Engineering Rules for WR03 Rack
BLANK PAGE BREAK
36 / 36 3BK 21591 AAAA PGZZA Ed.12