R/N:

Page: 2 of 68

Index
Item
Test
Description
Reference
Date of Test
(D/M/Y)
Result Location of Test Page
A. Characteristic Tests
A-1 Visual inspection
EN 50155:2001, 10.2.1
PASS AAEON LAB 3
A-2
Performance Test
(where applicable)
EN 50155:2001, 10.2.2 Supply variations: 0,7 U
PASS Cerpass 3
A-3 Insulation test
EN 50155:2001, 10.2.9.1 500 V DC
PASS Cerpass 3
A-4
Voltage withstand
test
EN 50155:2001, 10.2.9.2 1000 Vrms, sinusoidal
PASS Cerpass 3
B. Environmental Tests
B-1 Cooling test
EN 50155:2001, 10.2.3
EN60068-2-1, Ad
Ambient temperature: TX:
Internal cubicle
Temp 0~+55
PASS AAEON LAB 3
B-2 Dry heat test
EN 50155:2001, 10.2.4
EN60068-2-2, Bd

PASS AAEON LAB 4
B-3
Vibration, Shock,
and Bump test
EN50155:2001, 10.2.11
EN 61373

PASS King Design 5
B-4
Damp heat test
cyclic
EN50155:2001, 10.2.5
EN 60068-2-30, Db
+25C/+55C @ 2 x 24h,
2cycles
PASS AAEON LAB 11
C. EMC Tests
C-3
Conducted
emission
EN 50155:2001, 10.2.8.2
EN 50121-3-2 (Table 4)
EN 55011
79 dBV QP @ 150 - 500 kHz
73 dBV QP @ 500 kHz - 5 MHz
73 dBV QP @ 5MHz - 30 MHz
PASS
COMPLIANCE
LAB
12
C-4 Radiated emission
EN 50155:2001, 10.2.8.2
EN 50121-3-2(Table 6)
EN 55011
40 dBV/m QP @ 30 230kHz,
10m
47 dBV/m QP @ 230-1GHz,
10m
PASS
COMPLIANCE
LAB
15
C-5
Fast transient burst
immunity
EN 50155:2001, 10.2.7
EN 50121-3-2 (Table 8)
EN 61000-4-4
2 kV (capacitive clamp)
PC =A PASS
COMPLIANCE
LAB
20
C-6 Surge immunity
EN 50155:2001, 10.2.6.2
EN 50121-3-2 (Table 7)
1,8 kV, 5/50 us
2 Kv
PC =B
PASS
COMPLIANCE
LAB
22
C-7
RFI immunity,
Conducted
EN 50155:2001, 10.2.8.1
EN 50121-3-2 (Table 7)
EN 61000-4-6
10Vrms @ 0.15 - 80 MHz, 80 %
AM (1 kHz)
PC =A
PASS
COMPLIANCE
LAB
24
C-8
RFI immunity,
radiated
EN 50155:2001, 10.2.8.1
EN 50121-3-2 (Table 9)
EN 61000-4-3
10 V/m @ 80 - 1000 MHz, 80 %
AM (1 kHz)
PC =A
PASS
COMPLIANCE
LAB
26
C-9
Electrostatic
discharge
EN 50155:2001, 10.2.6.4
EN 50121-3-2 (Table 9)
EN 61000-4-2
6 kV contact discharge
8 kV air discharge
PC =B
PASS
COMPLIANCE
LAB
28




R/N:
Page: 3 of 68

A. Characteristic Tests

A-1 Visual inspection
A-1-1 Inspection Request
The visual inspection shall be carrier out to ensure that the equipment is of sound construction and, so far
as can be ascertained, meets its specified requirements.
A-1-2 Inspection Result
Pass: This is a FAN less product, therefore without any noise leakage except the Hard Disk Driver motor.

A-2 Performance Test (where applicable)
A-2-1 Test Condition
1. Supply variations:
- Supply voltage: (1) rated input voltage x 0.7 (2) rated input voltage x 1.25
- Operation function shall be worked normally at the supply variations.
2. Supply interruption:
- Supply voltage: rated input voltage.
- Interruption classification: Class S1.
- Repeated 10 times at random and covered all modes of operation.
- Operation function shall be worked normally at supply variations.
A-2-2 Test Result
1. Supply variations:
Test voltage (V) Result / Observation
DC 23.75 No malfunction
DC 13.3 No malfunction

2. Supply interruption:
Test voltage (V) Result / Observation
DC 19 No malfunction

A-3 Insulation test
A-3-1 Test Condition
- Test voltage: 500 Vdc.
- No fundamental deterioration from the initial measurement.
- Test voltage is applied between the power supply sides of external power adaptor and I/O ports
equipment under test.

A-3-2 Test Result
Test voltage (V) Result / Observation
DC 500 No fundamental deterioration


A-4 Voltage withstand test
A-4-1 Test Condition
- Test voltage: 1000 Vac or 1414Vdc.
- Test time: one minute.
- Neither disruptive discharge nor flashover shall occur.
- Test voltage is applied between the power supply sides of external power adaptor and I/O ports
equipment under test.

A-4-2 Test Result
Test voltage (V) Result / Observation
DC 1414 No disruptive discharge / no flashover


B. Environmental Tests
B-1 Cooling test

B-1-1 Test Equipment
Programmable Temperature & Humidity Chamber
K.SON. INS. TECH. CORP.
Model: TS-F3L+-100
Date of Calibration: 04/01/05
R/N:
Page: 4 of 68

Serial Number: 1467

B-1-2 Test Condition
1. Test Temperature: 0
2. Test Times: 96Hrs
3. Test Software: Windows 2000 / Run PassMark Burn In Test Pro 4.0


B-1-3 Machine Curve

B-1-4 Test Result
The system structure doesnt have any deformation; All functions are passed after low temperature
operation test.


B-2. Dry heat test

B-2-1 Test Equipment
Programmable Temperature & Humidity Chamber
K.SON. INS. TECH. CORP.
Model: TS-F3L+-100
Date of Calibration: 04/01/05
Serial Number: 1467

B-2-2 Test Condition
1. Test Temperature: 55
2. Test Times: 96Hrs
3. Test Software: Windows 2000 / Run PassMark Burn In Test Pro 4.0

B-2-3 Machine Curve
R/N:
Page: 5 of 68


B-2-4 Test Result
The system structure doesnt have any deformation; All functions are passed after high temperature
operation test.

B-3 Vibration, Shock, and Bump test
B-3-1 Test Equipment
SHOCK TEST
EQUIPMENT MFR MODEL
SERIAL
NUMBER
CAL.
DUE
Shock Testing System King Design KD-DP-1200-60KDS11054989 No Cal. Required
Controller King Design KD-1200-03 KD674 No Cal. Required
Accelerometer B&K B&K 4398 2209043 No Cal. Required

VIBRATION TEST
EQUIPMENT MFR MODEL
SERIAL
NUMBER
CAL.
DUE
Vibration Tester King Design
KD-9363EM-600F2K-
50N120
KDS11054783 No Cal. Required
Controller DACTRON FRONT-End Box 5250251 No Cal. Required
Control Accelerometer Wilcoxon Research WR-77 4208 No Cal. Required

B-3-2 Shock Test Condition
Temperature : 202
Humidity : 7020%RH
EUT : AEC-6910 with HDD
Wave From : Half sine wave(operation)
Acceleration : 30g
Duration Time : 18ms
No. of Shock : Each axis 3 times
Shock of direction : X, Y, Z axis

R/N:
Page: 6 of 68

B-3-3 Shock Test Photograph of test setup

R/N:
Page: 7 of 68



B-3-4 Shock Test Curve



R/N:
Page: 8 of 68




B-3-5 Shock Test Result


B-3-6 Vibration Test Condition
Temperature : 202
Humidity : 7020%RH
R/N:
Page: 9 of 68

EUT : AEC-6910 with HDD
Wave From : Random vibration test(operation)

Test Axis : Vertical
Frequency : 5~20 Hz
Acceleration : 5.40 m/s rms
P.S.D. : 5~10 Hz +9 dB/Oct
10~100 Hz 0.190 (m/s)/Hz
100~250 Hz -6 dB/Oct
Test Time : 1 hr

Test Axis : Transverse
Frequency : 5~250 Hz
Acceleration : 4.71 m/s rms
P.S.D. : 5~10 Hz +9 dB/Oct
10~100 Hz 0.144 (m/s)/Hz
100~250 Hz -6 dB/Oct
Test Time : 1 hr
Acceleration : 5.40m/s rms
Acceleration : 5.40m/s rms

Test Axis : Longitudinal axis
Frequency : 5~250 Hz
Acceleration : 2.52 m/s rms
P.S.D. : 5~10 Hz +9 dB/Oct
10~100 Hz 0.0414 (m/s)/Hz
100~250 Hz -6 dB/Oct
Test Time : 1 hr

Total test Time : 3 hrs

B-3-7 Vibration Test Photograph of test setup

R/N:
Page: 10 of 68


B-3-8 Vibration Test Curve

R/N:
Page: 11 of 68



B-3-5 Vibration Test Result


B-4. Damp heat test cyclic
B-4-1 Test Equipment
Programmable Temperature & Humidity Chamber
K.SON. INS. TECH. CORP.
Model: TS-F3L+-100
Date of Calibration: 04/01/05
Serial Number: 1467

B-4-2 Test Condition
1. Test Temperature: 25 / 55
2. Test Humidity: 93~95%RH
3. Test Cycle: 2 Cycle

B-4-3 Machine Curve
R/N:
Page: 12 of 68

3 h 6 h
95%
93%
24 h (1 Cycle)
25
9 h
T1
Ambient temp.
10 min
relative humidity
45 to 75%
dielectric test

B-4-4 Test Result
Pass: The system structure doesnt have any deformation; All functions are passed during humidity test.


C. EMC Tests
C-1 EUT DESCRIPTION
Product Embedded Control PC
Trade Name AAEON
Model AEC-6910
Housing Type Metal case
EUT Power Rating 100~240VAC
AC Power During Test 230VAC / 50Hz
Power Adaptor Manufacturer FSP
Power Adaptor Model Number FSP120-AAB
Power Adaptor Power Rating I/P: 100-240VAC 50-60Hz O/P: 19VDC
AC Power Cord Type Unshielded, 1.8m (Detachable)
DC Power Cord Type Unshielded, 1.6m (Non-detachable, with a core)
EUT I/O Cable Unshielded, 0.3m (Detachable)
OSC/Clock Frequencies 32.768kHz; 14.31818MHz; 25MHz

C-2 I/O PORT OF EUT
I/O Port Type QTY TESTED WITH
PIO Port 1 1
SIO Port 4 4
PS/2 Keyboard Port 1 1
PS/2 Mouse Port 1 1
VIDEO-OUT Port (VGA) 1 1
AUDIO IN/OUT/ MIC Port 1 1
LAN Port 1 1
USB Port 4 4
PCMCI Port 2 2
CF Slot 1 1

C-3 Conducted emission
C-3-1 Test Equipment
Conducted Emission Test Site # B
EQUIPMENT MFR MODEL
SERIAL
NUMBER
CAL.
DUE
TEST RECEIVER R&S ESHS10 843743/015 03/31/2006
LISN (EUT) EMCO 3825/2 9106-1810 01/16/2006
LISN EMCO 3825/2 1382 01/16/2006
BNC CABLE MIYAZAKI 5D-FB BNC B1 07/14/2006
Pulse Limiter R&S ESH3-Z2 100374 08/25/2006
THERMO-HYGRO METER TOP HA-202 9303-3 03/02/2006
R/N:
Page: 13 of 68


C-3-2 Test Photograph of test setup





C-3-3 Emission Profile
R/N:
Page: 14 of 68



R/N:
Page: 15 of 68



C-3-4 Performance and Result:
Pass: No any emission over the limit line.


C-4. Radiated emission
C-4-1 Test Equipment
Open Area Test Site J
EQUIPMENT MFR MODEL SERIAL no. CAL. DUE
SITE NSA CCS J Site N/A 10/15/2006
MEASURE RECEIVER SCHAFFNER SCR3501 330 06/13/2006
R/N:
Page: 16 of 68

SPECTRUM ANALYZER ADVANTEST R3132 120900003 No Cal. Required
ANTENNA SCHAFFNER CBL 6112B 2800 09/24/2006
PRE-AMPLIFIER SCHAFFNER CPA9231A 3629 10/08/2006
CABLE BELDEN 9913 N-TYPE #J 2 02/18/2006
ATTENUATOR MCL UNAT-6 AT06-8 12/03/2005
THERMO-HYGRO METER TFA N/A NO.3 11/02/2006


C-4-2 Test Photograph of test setup

R/N:
Page: 17 of 68



C-4-2 Emission Profile
R/N:
Page: 18 of 68


R/N:
Page: 19 of 68


C-4-3 Performance and Result:
Pass: No any emission over the limit line.

R/N:
Page: 20 of 68

C-5. Fast transient burst immunity
C-5-1 Test Equipment
Fast Transients/Burst Test Site (EN 61000-4-4)
Manufacturer/Type Model No. Serial No. Cal. Due
Schaffner / EFT Generator BEST EMC V2.3 200031A024SC 11/07/2006
Schaffner / Capacitive Clamp N/A N/A No Cal. Required

C-5-2 Test Condition
Port : AC Power Port and RJ 45 Port
Basic Standard : IEC/EN 61000-4-4
Requirements : 2 kV for AC Power Port
2 kV for RJ 45 Port
Performance Criterion : The Equipment or System shall be able to provide the essential performance and
remain safe.
Tested by : ALEX PAN
Temperature : 18
o
C
Humidity : 56%
Pressure : 1005mbar

C-5-3 Test Block Diagram of Test Setup
Controller Computer
EFT/Burst/
Surge Generator
EUT
Support
Units
0.8m
Non-Conductive Table
AC
Injection Clamp
Burst Generator
To Load
AC
Comm. Line 3 m
EUT
80cm
Non-Conductive
Table
10cm


C-5-4 Test Photograph of test setup
R/N:
Page: 21 of 68



(IEC 61000-4-4 FOR I/O)


C-5-5 Performance and Result
Impulse Frequency : 5kHz
Tr/Th : 5/50ns
Burst Duration : 15ms
Burst Period : 300ms
R/N:
Page: 22 of 68

Inject Line Voltage kV Inject Method Result (Pass/Fail)
L 2 Direct Pass
N 2 Direct Pass
PE 2 Direct Pass
L +N 2 Direct Pass
L +PE 2 Direct Pass
N +PE 2 Direct Pass
L +N +PE 2 Direct Pass
RJ 45 2 Clamp Pass
Pass: No function degraded during the tests.
The apparatus continues to operate as intended. No degradation of performance or loss of function is
allowed below a performance level specified by the manufacturer, when the apparatus is used as
intended. In some cases the performance level may be replaced by a permissible loss of performance.


C6 Surge immunity
C-6-1 Test Equipment
Surge Immunity Test Site (EN 61000-4-5)
Manufacturer/Type Model No. Serial No. Cal. Due
Schaffner / Surger Generator BEST EMC V2.3 200031A024SC 11/07/2006
Schaffner / Signal and Data
Lines Coupling Network
CDN118 19328 No Cal. Required

C-6-2 Test Condition
Port : AC Power Port
Basic Standard : IEC/EN 61000-4-5
Requirements : 2 kV(Line to Ground)) for AC Power Port
1.8kV(Line to Line) for AC Power Port
Performance Criteria : The Equipment or System shall be able to provide the
essential performance and remain safe.
Tested by : ALEX PAN
Temperature : 20
o
C
Humidity : 56%
Pressure : 1010mbar

C-6-3 Test Block Diagram of Test Setup
Surge Immunity
Test
Controller Computer
EUT
&
Support Units
0.8m
To AC
Source


C-6-4 Test Photograph of test setup
R/N:
Page: 23 of 68



C-6-5 Test Procedure
1. The EUT and support units were located on a wooden table 0.8 m away from ground floor.
2. Injected test voltage to the EUT ports from minimum to standard request or client request.
3. Recorded the test result as shown in following table.

C-6-6 Performance and Result
Voltage Waveform : 5/50 us
Current Waveform : 8/20 us
Polarity : Positive/Negative
Phase angle : 0
o
, 90
o
, 270
o
Number of Test : 5
Coupling Line Voltage (kV) Polarity Coupling Method Result (Pass/Fail)
L1-L2 11.8 Positive Capacitive
Pass
L1-PE 12 Positive Capacitive
Pass
L2-PE 12 Positive Capacitive
Pass
L1-L2 11.8 Negative Capacitive
Pass
L1-PE 12 Negative Capacitive
Pass
L2-PE 12 Negative Capacitive
Pass
Pass : Where normal functioning of LAN cant be achieved because of the impact of CDN on the EUT, no
test be required.
The apparatus continues to operate as intended. No degradation of performance or loss of function is
allowed below a performance level specified by the manufacturer, when the apparatus is used as
intended. In some cases the performance level may be replaced by a permissible loss of performance.


R/N:
Page: 24 of 68

C-7 RFI immunity, Conducted
C-7-1 Test Equipment
CS test (EN 61000-4-6)
Manufacturer/Type Model No. Serial No. Cal. Due
Schaffner / RF Generator NSG 2070-1 1061 08/03/2006
Schaffner / CDN CDN M316 19600 08/02/2006
Schaffner / CDN CDN M216 19294 08/02/2006
FCC / CDN FCC-801-M3-16A 99122 08/02/2006
Schaffner / EM Clamp KEMZ 801 19227 02/23/2006
Schaffner / CDN CDN T002 15881 01/13/2006
FCC / CDN FCC-801-T8-RJ 45 04025 06/23/2006
Schaffner / Attenuator INA2070-1 2061 No Cal. Required
FCC / CDN FCC-801-T4-RJ 45 04031 08/02/2006

C-7-2 Test Condition
Port : AC Power Port and RJ 45 Port
Basic Standard : IEC/EN 61000-4-6
Requirements : 10V, with 80% AM. 1kHz Modulation.
Injection Method : CDN-M3 for AC Power Port
CDN-T4 for RJ 45 Port
Performance Criterion : A (Standard Required)
Tested by : ALEX PAN
Temperature : 20
o
C
Humidity : 56%
Pressure : 1010mbar
Frequency Range : 0.15MHz-80MHz
Frequency Step : 1% of fundamental
Dwell Time : 3 sec
C-7-3 Test Block Diagram of Test Setup
CDN
EUT and
Support units
Power
Amplifier
PC
Controller
Ground Reference
10 cm isolation
supporter
0.1m<L <0.3m


C-7-4 Test Photograph of test setup
R/N:
Page: 25 of 68



C-7-5 Test Procedure
1. The EUT and support units were located at a ground reference plane with the interposition of a 0.1 m
thickness insulating support and the CDN was located on GRP directly.
2. Set the testing parameters of CS test software as per IEC/EN 61000-4-6.

C-7-6 Performance and Result:
R/N:
Page: 26 of 68

Range (MHz) Field Modulation Result (Pass/Fail)
0.15-80 10V Yes Pass
Pass: No function degraded during the tests.
The apparatus continues to operate as intended. No degradation of performance or loss of function is
allowed below a performance level specified by the manufacturer, when the apparatus is used as
intended. In some cases the performance level may be replaced by a permissible loss of performance.

C-8 RFI immunity, radiated
C-8-1 Test Equipment
Radiated Electromagnetic Field Immunity Test Site (EN 61000-4-3)
Manufacturer/Type Model No. Serial No. Cal. Due
Calibration of Field Chamber#RS RS3H-7 / RS3V-7 07/01/2006
Agilent / Signal Generator E4421B MY43350597 05/16/2006
AR / Electric Field Probe FP6001 305650 02/03/2006
Boonton / RF Voltmeter 9200B 328001AE 02/23/2006
BNC / Function Generator 625A 25451 02/17/2006
AR / Amplifier 100W1000M1 17564 No Cal. Required
Werlatone Inc. / Direction Coupler C2630 4121 No Cal.Required
Frankonia /Broadband Antenna BTA-M 030001M No Cal. Required
TOP / Thermo-Hygro meter HA-202 9303-2 03/02/2006

C-8-2 Test Condiction
Port : Enclosure
Basic Standard : IEC/EN 61000-4-3
Requirements : 10V/m / with 80% AM. 1kHz Modulation.
Performance Criterion : A (Standard Required)
Tested by : ALEX PAN
Temperature : 18
o
C
Humidity : 56%
Pressure : 1010mbar

C-8-3 Test Block Diagram of Test Setup

0.8m
Power Amp Signal
Generator
EUT Monitoring by
using a camera
Control Room
7x3x3
EUT &
Support Units
PC Controller to
control S.G. & PA as
well as forward
power
3 meter
1.5 meter

R/N:
Page: 27 of 68


C-8-4 Test Procedure
1. The EUT and support units were located at the edge of supporting table keep 3 meter away from
transmitting antenna, it just the calibrated square area of field uniformity.
2. Adjusting the cables to be exposed to the electromagnetic filed as possible.
3. Performing a Radiated Emission Scan in range of 80 to 1000 MHz prior to do RS test and records the
more higher emission frequencies for the reference of RS test, due to antenna effectiveness.
4. Adjusting the monitoring camera to monitor the H message as clear as possible.
5. Setting the testing parameters of RS test software per IEC 61000-4-3.
6. Referring to the tested data of step 3 to performing the RS test from 30 to 2300 MHz.
7. Recording the test result in following table.
8. Changing the EUT to the other side and repeat step 3 to 6, until 4 sides of EUT were verified.

C-8-5 Test Photograph of test setup

C-8-6 Performance and Result:
Test level : 10V/m
Steps : 1 % of fundamental
Dwell Time : 3 sec
Range (MHz) Field Modulation Polarity Position () Result (Pass/Fail)
80-1000 10V/m Yes H Front Pass
80-1000 10V/m Yes V Front Pass
80-1000 10V/m Yes H Right Pass
80-1000 10V/m Yes V Right Pass
80-1000 10V/m Yes H Back Pass
80-1000 10V/m Yes V Back Pass
80-1000 10V/m Yes H Left Pass
80-1000 10V/m Yes V Left Pass
Pass: No function degraded during the tests.
The apparatus continues to operate as intended. No degradation of performance or loss of function is
allowed below a performance level specified by the manufacturer, when the apparatus is used as
intended. In some cases the performance level may be replaced by a permissible loss of performance.



R/N:
Page: 28 of 68

C-9 Electrostatic discharge
C-9-1 Test Equipment
ESD Test Site (EN 61000-4-2)
Manufacturer/Type Model No. Serial No. Cal. Due
Schaffner / ESD Simulator NSG 438 129 04/20/2006
Sato / Aneroid Barometer 7610-20 89090 08/29/2006
TOP / Thermo-Hygro meter HA-202 9303-1 03/02/2006
C-9-2 Test Condition
Port : Enclosure
Basic Standard : IEC/EN 61000-4-2
Test Level : 8kV (Air Discharge)
6kV (Contact Discharge)
Performance Criterion : The Equipment or System shall be able to provide the
essential performance and remain safe.
Tested by : ELVIS ZENG
Temperature : 19
o
C
Humidity : 59% RH
Pressure : 1005mbar

C-9-3 Test Block Diagram of Test Setup

Ground Reference Plane
Wooden Table
Indirect
Support units
EUT & its direct
Support Units
VCP
HCP
>1m
0.8m

(The 470 k resistors are installed per standard requirement.)

C-9-4 Test Photograph of test setup
R/N:
Page: 29 of 68



C-9-5Test Performance and Result
The electrostatic discharges were applied as follows:
Amount of Discharges Voltage Coupling Result
20 / Point 8kV Air Discharge Pass
20 / Point 6 kV Contact Discharge Pass
20 / Point 2, 4, 6 kV Indirect Discharge HCP Pass
20 / Point 2, 4, 6 kV Indirect Discharge VCP (Front) Pass
20 / Point 2, 4, 6 kV Indirect Discharge VCP (Left) Pass
20 / Point 2, 4, 6 kV Indirect Discharge VCP (Back) Pass
20 / Point 2, 4, 6 kV Indirect Discharge VCP (Right) Pass
Observation: No function degraded during the tests.