You are on page 1of 16

545 West Terrace Drive

San Dimas, CA 91773

Description:

Document 90-005-0017
No:

Rev:

Author:

Date: 4/7/08

EH,GE

X02

MatchBox AC-DC Supply


Part Number: MBP-000300-XXXX Family
For use with Wavestreams Ku-band (16W-40W) and Ka-band
Matchbox Amplifiers

Matchbox AC-DC Supply


SPECIFICATIONS
PRIME

90-264 VAC, 50-60Hz

Prime Power

Better than 90%

Efficiency

INTERFACE

C016 20D003 110 12

AC Input Connector
Monitor and Control Input
Connector

MS3126F14-19S

DC and Monitor and Control


Output Connector

MS3126F18-32P

ENVIRONMENTAL

Operating Temperature

-40oC to +60oC ambient air temperature


IP-54

Water Ingress

MECHANICAL

Size

5.4 W x 3.5 H x 9.1 L (138 mm W x 89 mm H x 231 mm L)


6.1 lbs (2.8 Kg)

Weight

Doc. 90-005-0017 Rev. X02

Page 2 of 16

Matchbox AC-DC Supply


INTERFACES
AC Prime Power Requirements:
Voltage

115VAC, single phase

Current

15A circuit or greater

Other

Do not run on a Ground Fault Interrupt protected circuit.


Note: It is advisable to run unit off a circuit with no ground fault
interrupt (GFI). The unit is high power and has a number of decoupling
capacitors for noise that connect to ground. There may be enough
current on the ground to trip a sensitive GFI circuit.

Electrical Interfaces:
Interface

Description

Connects to

Output DC Power and Monitor and Control

MatchBox

Label
J1

32 Contacts, Sockets
(see Interface Specifications for mating connector)
J2

Monitor and Control

Customer M/C

19 Contacts, Pins
(see Interface Specifications for mating connector)
J3

AC Prime Power

AC Prime
Power

4 Contacts, Pins
(see Interface Specifications for mating connector)

Doc. 90-005-0017 Rev. X02

Page 3 of 16

Matchbox AC-DC Supply


Mechanical Interfaces:
There are four mechanical mounting points, two each on two sides. Each takes a 1/4-20 screw
which will not protrude further than 0.30 into the unit. The mounting points are depicted here
on the mechanical drawing as the features described with the 2X 1/4-20 UNC
.30 callout.
Full mechanical drawings can be found in the Outline and Mounting Drawings section.
Note: Do not use screws that are too long. When installing mounting hardware, if it feels
like the screw is bottoming out, check the screw length to be sure the screw is not too long.

Operating Instructions
Unpacking
Keep the shipping box and all packing materials for future use including return of the Unit for
repair.
Check the Unit for any visible damage. If the Unit is damaged, call Wavestream for an RMA
number.

Inspect Interfaces
Inspect connectors and connector pins and remove any foreign objects such as packing material.

Perform Continuity Check on the Cables


Doc. 90-005-0017 Rev. X02

Page 4 of 16

Matchbox AC-DC Supply


Even if the cables have been made in advance, it is important to use and ohm meter to perform a
continuity check on each of the individual wires. Incorrect wiring could permanently damage the
Unit.
Pin-out tables are included at the end of this manual.

Installation and Connections


Proceed with installation according to standard practice.
See section on Mounting for mounting point specifications. Make sure that any screws used to
mount the unit are the correct length.
Connect the Output DC Power and Monitor and Control (J1) connector to the MatchBox Input
DC Power and Monitor and Control.
Connect the Monitor and Control (J2) connector. Note: the monitor and control signals are
simply passed through the AC/DC Power Supply Unit from the MatchBox. For details on the
M/C signals, see MatchBox Manual.
Connect the AC Prime Input (J3) connector to Prime AC Power source.
Note: Do not connect power to the Unit until the MatchBox is installed on the feed
and antenna. The MatchBox emits high power RF energy which could be harmful to the
human body.

Voltage

115VAC, single phase

Current

15A circuit or greater

Other

Do not run on a Ground Fault Interrupt protected circuit.


Note: It is advisable to run unit off a circuit with no ground fault
interrupt (GFI). The unit is high power and has a number of decoupling
capacitors for noise that connect to ground. There may be enough
current on the ground to trip a sensitive GFI circuit.

Doc. 90-005-0017 Rev. X02

Page 5 of 16

Matchbox AC-DC Supply

Transmit Enable Configuration


Note: the monitor and control signals are simply passed through the AC/DC Power Supply Unit
from the MatchBox. For details on the M/C signals, see MatchBox Manual.
Hard-wired Enable:
If it is desired that the unit enables RF operation as soon as power is applied without
having to send a command, the unit should have a hard-wire TX Enable wire installed. To do this,
connect pin A (Secondary GND) to pin B (/TX_EN) on J2.
Once TX Enable is hardwired to be enabled, there is no way to disable the unit using
commands. The unit must be powered down to disable it.
Discrete Enable:
If it is desired that the unit enables RF operation using the discrete enable signal without
having to send a command, the unit should be wired to an open collector on the customer side.
To do this, connect pin A (Secondary GND) and pin B (/TX_EN) on J2 to the customer open
collector circuit.
Once TX Enable is enabled using the discrete signal, there is no way to disable the unit
using commands. The open collector circuit can be switched so that /TX_EN is not grounded, or
the unit may be powered down to disable it.
RS-485 Serial Command Enable:
If it is desired that the unit enables RF operation using a serial command enable signal,
the unit should be have the serial wires connected as follows:
Pin

Unit Signal
Name

Customer Side
Connection

RX-

TX-

RS-485 GND

Ground

TX-

RX-

RX+

TX+

TX+

RX+

If the unit is powered down, the unit will automatically come up disabled and a serial
command must be sent to enable the unit. For more information about the M/C serial operation
of the unit, see the MatchBox Manual.

Doc. 90-005-0017 Rev. X02

Page 6 of 16

Matchbox AC-DC Supply


Cable Identification
If you are using cables from Wavestream to connect to the unit, the part numbers provided
correspond to the Wavestream cables.

J1 AC/DC Output connector. Connect this to the Matchbox.


Wavestream PN: 02-009-0091: 4ft cable
Wavestream PN: 02-009-0092: 8ft cable

Attach Cable between J1 on the AC/DC Power Supply and the Power and M/C Connector on
the MatchBox.

Doc. 90-005-0017 Rev. X02

Page 7 of 16

Matchbox AC-DC Supply

J2 AC/DC Monitor and Control connector.


Wavestream PN: 02-009-0093: D-sub cable

Customer
RS-485
Serial
DB-9
Connector

Attach Cable between J2 on the AC/DC Power Supply and customer RS-485 serial
connector.

Doc. 90-005-0017 Rev. X02

Page 8 of 16

Matchbox AC-DC Supply

J3 AC/DC Prime AC Power connector.


Wavestream PN: 02-009-0094: AC cable

Customer
115VAC
Single Phase
Prime
Power
Connection
Attach Cable between J3 on the AC/DC Power Supply and customer AC Prime Power
connection.
Note: It is advisable to run unit off a circuit with no ground fault interrupt
(GFI). The unit is high power and has a number of decoupling capacitors for
noise that connect to ground. There may be enough current on the ground to
trip a sensitive GFI circuit.

Doc. 90-005-0017 Rev. X02

Page 9 of 16

Matchbox AC-DC Supply


Outline and Mounting Drawings

Top View

Side View

Doc. 90-005-0017 Rev. X02

Page 10 of 16

Matchbox AC-DC Supply

Front View

Doc. 90-005-0017 Rev. X02

Page 11 of 16

Matchbox AC-DC Supply


J1 M&C and DC Output
Mating Connector: MS3126F18-32P
J1 M&C and DC Output Pinout
Pin
A
B
C
D
E
F
G
H
J

Signal
Prime
Prime
Prime
Prime_Rtn
TX+ Ethernet
TX- Ethernet
RX+ Ethernet
RX- Ethernet
RS-485 GND

Signal Type
Power
Power
Power
Power Rtn
Com
Com
Com
Com
RS-485 GND (use with RS-485)

K
L
M
N
P
R
S
T
U
V
W
X
Y
Z
a
b
c
d
e
f

RX- RS-485
RX+ RS-485
TX- RS-485
TX+ RS-485
Prime_Rtn
Prime
Prime
Prime
Prime_Good_Ref
Prime_Rtn
Prime_Rtn
TX_Active
HPA_Off
Over_Temp
Analog_Temp
Lock_Loss
Sum_Fault
Prime_Rtn
Prime_Rtn
Prime_Good

g
h
j

/TX_EN
GND
/LED_Off

Com
Com
Com
Com
Power Rtn
Power
Power
Power
Prime_Good Reference
Power Rtn
Power Rtn
Monitor TTL
Monitor TTL
Monitor TTL
Monitor Analog (0 to +5V)
Monitor TTL
Monitor - TTL
Power Rtn
Power Rtn
MonitorAnalog/TTL (0 to
+5.6V)
Control
Secondary GND
Control

Doc. 90-005-0017 Rev. X02

Page 12 of 16

Reference
Prime_Rtn
Prime_Rtn
Prime_Rtn
Secondary GND
Secondary GND
Secondary GND
Secondary GND
Digital GND, Secondary
Side
Secondary GND
Secondary GND
Secondary GND
Secondary GND
Prime_Rtn
Prime_Rtn
Prime_Rtn
Filtered Prime_Rtn

Secondary GND
Secondary GND
Secondary GND
Secondary GND
Secondary GND
Secondary GND

Prime_Good_Ref
Secondary GND
Secondary GND

Matchbox AC-DC Supply

Prime RTN

Prime_Good Ref

S
U

Prime
P

Prime_Good

Secondary GND

f
d

W
g

j
Secondary

E
o

h
Y

Prime

Control Sig
Reference to SGND
Monitor Sig
reference to SGND

a
L

G
K
J

Male

Ethernet

Serial RS-485

Serial RS-485 DGND

Looking at the front of the pins

J1 M&C and DC Output Layout

Doc. 90-005-0017 Rev. X02

Page 13 of 16

Matchbox AC-DC Supply


J2 - M&C Input
Mating Connector: MS3126F14-19S
J2 M&C Input Pinout
Pin
A
B

Signal
GND
/TX_EN

Signal Type
Secondary GND (SGND)
Control

C
D

RX- Ethernet
Lock_Loss

Com
Monitor TTL

E
F

Prime_Good_Ref Prime_Good Reference


Filtered MatchBox Prime RTN
RX- RS-485
Com

RS-485 DGND

TX- RS-485

Prime_Good

Sum_Fault

Monitor TTL/Analog
(0 to +5.6V)
Monitor - TTL

L
M

TX- Ethernet
/LED_Off

Com
Control

N
P
R

TX+ Ethernet
RX+ Ethernet
HPA_Off

Com
Com
Monitor TTL

RX+ RS-485

Com

TX+ RS-485

Com

TX_Active

Monitor TTL

Over_Temp

Monitor TTL

Doc. 90-005-0017 Rev. X02

RS-485 Digital GND Secondary Side


(ground to be used with RS-485)
Com

Page 14 of 16

Reference
Pin A
Secondary GND
Secondary GND
Pin A
Secondary GND

Pin G
RS-485 DGND

Pin G
RS-485 DGND
Pin E
Prime_Good_Ref
Pin A
Secondary GND
Secondary GND
Pin A
Secondary GND
Secondary GND
Secondary GND
Pin A
Secondary GND
Pin G
RS-485 DGND
Pin G
RS-485 DGND
Pin A
Secondary GND
Pin A
Secondary GND

Matchbox AC-DC Supply

Male
Viewed from
the front face

Secondary Side Signals


Q

Com Signals

Secondary GND (SGND)

Q Control Signal

Monitor Signal
reference to SGND

Prime Side Signals


(MatchBox DC Prime, not AC Prime)
Q

Prime Good

Prime Good Reference

J2 M&C Input Pin Layout

Doc. 90-005-0017 Rev. X02

Serial RS-485
reference to DGND

Q Serial RS-485 DGND

reference to SGND

Page 15 of 16

Ethernet

Matchbox AC-DC Supply


J3 AC Input
Mating Connector: C016 20D003 110 12
J3 AC Input Pinout
Pin
1
2
3
GND

Signal

Signal Type
Line
No Connect
Neutral
GND

Connector as
viewed from
the front face

J3 M&C Input Pin Layout

Doc. 90-005-0017 Rev. X02