FO R D E C O R AT I N G M AT E R I A L S
Introduction
*Research conducted by utility giant DTE Energy. The Carbon Trust recommends destratification as one of its top 3 carbon saving
measures.
Main Benefits
Reduces heating and/or cooling costs by 20% - 50%
Reduces CO2 emissions by 20% - 50%
Maximises comfort levels
Minimal running costs (from 12 / pa)
Additional Benefits...
Recycles heat from machinery, lighting, solar gain etc.
Reduces condensation
Small, versatile and unobtrusive units
Simple to install with no ducting required
Stand alone or BMS integrated
Minimal maintenance required
Reduces pre-heat time by up to 60%
Works alongside and reduces wear on all HVAC systems
Eligible for carbon reducing grants / loans
Simple, inexpensive and efficient CRC solution
Increases lighting lifespan
5 seconds
10 seconds
20 seconds
30 seconds
Installation
A typical installation includes a series of units
mounted just below the ceiling, evenly spaced
throughout a facility.
*Smoke machine used for air pattern visualisation. Model 45/PS-4 mounted at 9 metres.
10C
(0.3m)
(10m)
BEFORE AIRIUS
0C - 2C
20 - 50%
(10m)
(0.3m)
AFTER AIRIUS
5
BSRIA
Figure 1
<17
19
21
23
>25
Temp in C
Figure 2
<17
19
21
23
>25
Temp in C
6
STANDARD
s e r i e s
The Airius Standard Series is available in several models with various
motors/controls to accommodate ceiling heights from 2.5 to 31 metres, ranging
from the short model 10 to the largest model 100. Standard Series units are
available in off white or can be custom painted to match any RAL colour code.
DESIGNER
s e r i e s
The Designer Series functions the same as the Standard Series, except it is
enclosed in a custom made cylindrical housing for architecturally sensitive
installations. The Designer Series can also be custom painted to match any RAL
colour code and accommodates ceiling heights up to 38 metres high.
SUSPENDED
s e r i e s
5
7
The Airius PureAir Series (Air purification and odour control system)
significantly improves indoor air quality (IAQ) reducing viruses,
bacteria, gases, VOCs (Volatile Organic Compounds), sick building
syndrome, mould and odours by over 90% whilst an advanced
atmosphere oxidisation technology gives indoor environments fresh,
clean and odour free air. This is in addition to the standard features
and benefits of the Airius destratification system.
For further information and how it works details please refer to the
Airius website at www.airius.co.uk.
Technical Information
Standard Series
Model 10
Model 125
Model 15
Model 25
Model 60
Model 45
Model 45
Model 60
Model 100
Model 25
Model 15
Model 10
Designer Series
Airius units are available as free hanging fans applicable for ceiling heights from 2.5m to 38m, or can be
installed into suspended ceilings up to 12 metres with our 600mm x 600mm Suspended Series kit. Wattages
marked with an * in the chart below apply to the Airius PureAir Series.
Technical Specifications
Model 15
Model 25
Model 45
Model 60
Model 100
4m - 6m
6.5m - 8m
8.5m - 14m
15m - 19m
20m - 31m
20m - 38
Diameter Coverage:
11m - 7m
12m - 8m
15m - 10m
15m - 10m
18m - 12m
21m - 14m
23m - 15m
72m - 48m
90m - 60m
133m - 89m
133m - 89m
222m - 148m
279m - 186m
334m - 223m
200
230
230
230
230
230
230
Watts @ 50 Hz:
12 / *22
15 / *25
31 / *41
42
120
390
400
RPM @ 50 Hz:
980
1230
1450
1400
1390
1690
1000
CFM @ 50 Hz:
318
406
460
595
1667
3358
5200
m/hr:
540
690
780
1010
2832
5705
8835
AMPS @ 50 Hz:
.06
.06
.13
.19
.57
2.5
1.8
-10C
-10C
-10C
-10C
-10C
-10C
-10C
110C
110C
110C
135C
135C
135C
135C
Volts:
Model 125
Model 10
2.5m - 3.5m
Ceiling Heights:
Reset Temp:
90C
90C
90C
125C
125C
125C
125C
Noise Level:
0 - 25dB
0 - 30dB
0 - 34dB
0 - 34dB
0 - 47dB
0 - 43dB
0 - 41dB
Motor data provided by motor manufacturer and is subject to change at any time. Noise levels recorded from installed units at floor level.
*Applicable to Airius PureAir Series.
Accurate as of February 2014. Each facility has unique fluid dynamics, please contact supplier to specify your system.
Warranty
Standard and Designer Series units:
All Standard and Designer Series units come with a 3 year replacement warranty
return defective units to Airius Europe carriage paid upon receipt Airius will
dispatch a new unit by return carriage paid.
Y
E
N
O
M
Y
A
D
120
E
E
T
N
A
R
A
U
G
K
BAC
A unique offer unmatched by
destratification fan manufacturer!
any
other
10
Testimonials
The thermostat has been turned down way beyond the point
that I thought was humanly possible!
Nick Brewer Director C Brewers & Sons Ltd
Within one week of activating the [PureAir] units there was a 40% decrease in mold
spores and a noticeable difference in VOCs. Within two weeks, airborne spores
were reduced by 70%, and VOCs were virtually eliminated. After three weeks,
airborne spores were reduced by 92%.
Rob Warren Winemaker Tara Winery
13
Lush Cosmetics
Poole Manufacturing Facility
Key Points:
ROI = 26 DAYS!!
61% Energy saving on heating system
Heating spend pre Airius = 26,638.83
Heating spend post Airius = 7,333.38
2,967.50 - Full system & installation cost
68.75 - Airius system annual running cost
Now recirculates process heat for free heating
Pre Airius
2,000.00
Post Airius
1,000.00
Dec 11 / 12
Jan 12 / 13
Feb 12 / 13
14
I mpress
Key Points:
45.07% - Overall Savings 08/09
62,351 - first winter savings
21,268 - full system & installation cost
3,000m - floor area
5.7C - mean temp 07/08
3.4C - mean temp 08/09
793 - Airius running costs per winter season
Installed into Can Assembly area
System - 34 units
Part of the Ardagh Group
Hello Airius,
Please find attached our analysis and data report. I have already
forwarded the findings to our environment manager and i have spoken to
two other plants in Germany and France.
Paul Matten
Plant Engineer
Aug 07
Sept 07
Oct 07
Nov 07
Dec 07
Jan 08
Feb 08
Mar 08
Apr 08
May 08
Jun 08
Jul 08
Aug 08
Sept 08
Oct 08
Nov 08
Dec 08
Jan 09
Feb 09
Mar 09
Apr 09
May 09
15
Qty (Ltrs)
0
0
17,000
17,000
33,999
33,999
44,104
50,999
17,000
34,000
17,000
0
0
0
0
17,000
34,000
34,000
34,000
34,214
17,069
13,687
Cost ()
0
0
7,080
7,242
16,302
16,591
27,054
25,595
9,239
19,291
9,943
0
0
0
0
9,348
17,126
15,535
15,212
14,196
6,706
5,714
From: paul.mattin@uk.imp-group.com
Sent: 26 August 2009 13:54
Subject: Report
Regards,
60k
50k
25k
40k
20k
30k
15k
20k
10k
10k
5k
Sept
Nov
Jan
Mar
May
30k
Sept
Nov
Jan
Mar
May
Morrisons Supermarket
- Knottingly Store
Morrisons, the fourth largest supermarket chain in the UK, is
always looking for ways to reduce their energy costs and carbon
footprint and ways to increase customer comfort.
Supermarket operators and their HVAC consultants have been
trying to resolve the age old problem of cold chiller aisles and
uncomfortably warm clothing aisles for many years. Costly and
inefficient ducting systems, under cabinet heaters and heat retrieval systems have failed to solve the problem to date.
Mitton Mechanical, a Morrisons contractor, approached Airius in late 2007 to conduct a trial in the Morrisons Knottingly
store in Wakefield. Airius units were placed at 4 metre intervals in three chiller aisles in the hope of reducing the
stratification from 6-8C to 1-2Cthus making the chiller aisles more comfortable (without adversely affecting the chiller
units). More comfortable chiller aisles should increase the aisle spend as less shoppers rush through a cold area. A side
benefit is to eliminate freezer/cabinet fogging.
The trial was hugely successful and over 100 Morrisons stores have now been retrofitted with the Airius units. The Airius
units are now on the standard specification list for all new stores and will be retrofitted as part of the normal refurbishment
program.
Morrisons and Mitton Mechanical are a pleasure to work with. Their eagerness to reduce energy consumption and increase
the comfort levels for customers puts them at the very top of the Green supermarket list, which is why they were the first
supermarket in the UK to be awarded the prestigious Carbon Trust Standard for making real reductions in their carbon
emissions and energy usage.
16
Key Points:
ROI = Under 18 months
12,106 - First year saving
19,799 - Full system & installation cost
1,141,113.06 - KwH 08/09
709,956.00 - KwH 09/10
Installed into Acton rail maintenance shed
System - 26 Airius Model 45 units
75 tonnes - Approx. annual CO reduction
Thousands
2008/09
2009/10
4
2
23
22
21
20
Temp C
19
Ground Level
18
Cant Level
17
Airius On
16
Airius O
15
14
24/01/12
The graph above shows the temperature dierentials in the Acton rail maintenance shed at both ground level and cant rail
level with the Airius system o during the week 30/01/12 - 05/02/12, and running during the week 24/01/12 - 29/01/12.
17
00:00
16:00
25/01/12
08:00
00:00
16:00
26/01/12
08:00
00:00
16:00
27/01/12
08:00
00:00
16:00
28/01/12
08:00
00:00
16:00
29/01/12
08:00
00:00
16:00
30/01/12
08:00
00:00
16:00
31/01/12
08:00
00:00
16:00
01/02/12
08:00
00:00
16:00
02/02/12
08:00
00:00
16:00
04/02/12 03/02/12
08:00
00:00
16:00
08:00
00:00
16:00
05/02/12
08:00
00:00
16:00
12
08:00
13
Newmarket Motors
- Cork Showroom
Newmarket Motors installed the Airius system into their
Cork showroom through their licensed contractor
Electrical Mechanical Controls Ltd.
They needed to resolve the uncomfortably high
temperatures experienced on their first floor and the
uncomfortably low temperatures found on their ground
floor, which were creating unsuitable conditions for their
staff to work in.
Key Points:
Approx. 12C heating reduction.
A/C settings reset from high to low.
Heating reduced by approx. 24 hours per week.
First floor conditions resolved by recirculating
the uncomfortably high temperatures to floor
level where conditions were too cold, thus also
solving the ground floor low temperature problem.
"We (Electrical Mechanical Controls Ltd - Ireland) surveyed the VW Showroom as the owner had expressed that he was having
problems with uneven temperatures between the upstairs offices and downstairs offices and showroom. Staff upstairs were too
hot and the staff downstairs were working with their coats on at times. The Showroom has 3 sides of glass, floor to roof. They
have 4 combined heating/cooling units with the temperature set at between 30 33C with 4 blowers set to maximum.
We installed 3 Airius Model 25s and we are awaiting the electricity bills to show definite reductions. In the meantime, the
temperature on the A/C units have been reset at between 18 22C with the 4 blowers on the low setting and 2 of these are
turned off intermittently for approx. 2 4 hours per day.
Staff on both floors commented on the lovely comfortable temperature in comparison to before the system was fitted. These
have been monitored during the cold spell of weather that we are experiencing at the moment."
Sean Browne - Director - Newmarket Motors
18
Airius Americas
Airius, LLC
811 South Sherman Street
Longmont, Colorado
80501 USA
Tel - (00) 1 888 247 7327
Fax - (00) 1 303 772 8276
Email - Info@theairpear.com
Web - www.theairpear.com
QUOTE REF: WB-US
Airius Oceania
PO Box 6282, Alexandria
NSW 2015
AUSTRALIA
Tel - (00) 61 0 401 848 888
Email - info@airius.com.au
Web - www.airius.com.au
QUOTE REF: WB-AU
USA and foreign Patents granted to AIRIUS LLC, USA, further patents pending.
AIRIUS & AIRIUS SYSTEMS is the copyright property of AIRIUS LLC, USA.