You are on page 1of 7

9 9 2 6 S e r i e s B r a n c h R a t e d C i rc u i t B re a k e r s A C Ve r s i o n

Circuit Breakers
Hydraulic Magnetic Type

9926 Series
Double Pole

Single pole and double pole versions


120/240 VAC, 50/60 Hz
Up to 25A
Just 13 mm wide
Mounts on 35mm DIN-rail
UL 489 listed, CSA C22.2 No. 5-02, CE
VDE

Ordering Data

Technical Data
Voltage
Current

Type: Single Pole


Current Ratings
(amps)

Part No.
TS 35

0.5
1

Description

Part No.
TS 35

Description

9926251000
9926251001

QL-1-13-DM-KM-0.5
QL-1-13-DM-KM-01

0.5
1

9926252000
9926252001

QL-2-13-DM-KM-0.5
QL-2-13-DM-KM-01

9926251002

QL-1-13-DM-KM-02

9926252002

QL-2-13-DM-KM-02

3
4

9926251003
9926251004

QL-1-13-DM-KM-03
QL-1-13-DM-KM-04

3
4

9926252003
9926252004

QL-2-13-DM-KM-03
QL-2-13-DM-KM-04

5
6

9926251005
9926251006

QL-1-13-DM-KM-05
QL-1-13-DM-KM-06

5
6

9926252005
9926252006

QL-2-13-DM-KM-05
QL-2-13-DM-KM-06

9926251007

QL-1-13-DM-KM-07

9926252007

QL-2-13-DM-KM-07

8
10
13
15
16

9926251008
9926251010
9926251013
9926251015
9926251016

QL-1-13-DM-KM-08
QL-1-13-DM-KM-10
QL-1-13-DM-KM-13
QL-1-13-DM-KM-15
QL-1-13-DM-KM-16

8
10
13
15
16

9926252008
9926252010
9926252013
9926252015
9926252016

QL-2-13-DM-KM-08
QL-2-13-DM-KM-10
QL-2-13-DM-KM-13
QL-2-13-DM-KM-15
QL-2-13-DM-KM-16

20
25

9926251020
9926251025

QL-1-13-DM-KM-20
QL-1-13-DM-KM-25

20
25

9926252020
9926252025

QL-2-13-DM-KM-20
QL-2-13-DM-KM-25

9926 Series AC Version - dimensions in mm (in.)


120/240 VAC, 50/60Hz
0.5A
25A

66
(2.6)

5
(0.2)

Additional trip curves and amp ratings are available


upon request.

Minutes
Tripping Time

10

0.01

0.001

0.001

(%) Rated Current

4000
5000

0.01

2000
2500
3000

0.1

1500

Seconds

1000

Although the 9926 series uses a magnetic only trip mechanism, CSA
testing indicates a trip characteristic similar to thermal magnetic trip
mechanisms. No de-rating is required at elevated temperatures.

300

0.4

0.1

Ambient Temperature 30C

10

100
105
125
150
200

0.6

4000
5000

1.5

10

2000
2500
3000

1500

28

10

1000

125% 150% 200% 400% 600% 800% 1000%


minimum 15
8
4
0.7
0.09 0.007 0.005
(sec)

100

Ambient Temperature 30C

400
500

Sample trip characteristics - KM

Tripping Time

Trip CurvesHydraulic Magnetic Type


Typical time/current characteristics at 30C

Operating Characteristics
Curve KM

Operating Characteristics
Curve 1

100

*Wire sizes: gauges specified are the minimum allowable as per CSA
and UL standards.

9926 SeriesAC version Trip Curve


1000

1000

400
500

9926 SeriesAC version Trip Curve

67101960
67101961
67101913

The 9926 circuit breakers do not have provisions for marking tags.
A possible solution is to cut the adhesive SchS2 tag rail to length
(approximately 20 mm on a single pole unit so the current rating
remains visible or approximately 30 mm on a two pole unit).
The SchS2 accepts DEK, WS and ESG 8/17 marking tags.
The part number for adhesive SchS2 is 1720600000.

45
(1.77)
64.8
(2.55)

Minutes

Power lug, straight


Power lug, 90
Lock-out handle

13
(0.51)

32
(1.26)

100
105
130
150
200

67101904
67101972
67101973
67101974

19
(0.75)

Seconds

(1 pole, insulated, 1 m)
(2 pole, insulated, 1 m)
end cap, 1 pole
end cap, 2 pole

92.8
(3.65)

57
(2.24)

71.4
(2.81)

100MM
10000 mechanical operations
-40+65C

0.5-15A:
14AWG min., 10AWG max.
20-25A:
10AWG min.
Torque
20 in.-lb
Approval
UL 489 listed, CSA C22.2 No. 5-02, CE, VDE
Accessories
Part No.

90

26
(1.02)

10,000A
1500V, 50/60Hz

Insulation resistance
Operating life
Operating temperature
Wire size*

maximum 300
(sec)

13
(0.51)

28.5
(1.12)

Interrupting capacity
Dielectric strength

17.9
(0.7)

74
(2.91)

minimum
maximum

Bus-bar
Bus-bar
Bus-bar
Bus-bar

Type: Double Pole


Current Ratings
(amps)

300

9926 Series
Single Pole

(%) Rated Current

Trip Curve 1 applies to the following part numbers where


"XX" is the current rating:
Single Pole 99262512XX
Double Pole 99262522XX

9 9 2 6 S e r i e s B r a n c h R a t e d C i rc u i t B re a k e r s A C Ve r s i o n w i t h C o n t a c t s
Circuit Breakers with
Auxiliary switch, Trip alarm,
Combination of both

9926 Series
Single Pole
w/ Auxiliary Contact

9926 Series
Single Pole Trip
(Alarm Contact)

9926 Series
Single Pole Combination
(Auxiliary & Alarm Contact)

AC voltages (120/240V)
Single and double pole versions
UL 489 and CSA listed
Factory fitted auxiliary or trip alarm
Compact 6.5mm width
Attached to right hand side of
circuit breaker
Technical Data

Type: Single Pole Aux

Voltage

120/240 VAC, 50/60Hz

Current
minimum
maximum
Interrupting capacity

Current
Ratings
(amps) Part No.
1 9926261001
2 9926261002
5 9926261005
10 9926261010
15 9926261015
20 9926261020
25 9926261025

0.5A
25A
10,000A

Dielectric strength
Insulation resistance
Operating life

1500V, 50/60Hz
100MM
10000
mechanical operations
Operating temperature
-40+65C
Wire size*
0.5-15A:
20-25A:
Torque

14AWG min., 10AWG max.


10AWG min.
20 in.-lb

Description
QL-A-1-13-DM-KM-1
QL-A-1-13-DM-KM-2
QL-A-1-13-DM-KM-5
QL-A-1-13-DM-KM-10
QL-A-1-13-DM-KM-15
QL-A-1-13-DM-KM-20
QL-A-1-13-DM-KM-25

Current
Ratings
(amps) Part No.
1
9926281001
2
9926281002
5
9926281005
10 9926281010
15 9926281015
20 9926281020
25 9926281025

Description
QL-T-1-13-DM-KM-1
QL-T-1-13-DM-KM-2
QL-T-1-13-DM-KM-5
QL-T-1-13-DM-KM-10
QL-T-1-13-DM-KM-15
QL-T-1-13-DM-KM-20
QL-T-1-13-DM-KM-25

9926 Series
Double Pole Trip
(Alarm Contact)

9926 Series
Double Pole
w/ Auxiliary Contact

Approval
UL 489 listed, CSA C22.2 No. 5-02, CE, VDE

Type: Single Pole Combo

Type: Single Pole Trip

Current
Ratings
(amps) Part No.
1
9926271001
2
9926271002
5
9926271005
10 9926271010
15 9926271015
20 9926271020
25 9926271025

Description
QL-AT-1-13-DM-KM-1
QL-AT-1-13-DM-KM-2
QL-AT-1-13-DM-KM-5
QL-AT-1-13-DM-KM-10
QL-AT-1-13-DM-KM-15
QL-AT-1-13-DM-KM-20
QL-AT-1-13-DM-KM-25

9926 Series
Double Pole Combination
(Auxiliary & Alarm Contact)

*Wire sizes: gauges specified are the minimum


allowable as per CSA and UL standards.
The 9926 circuit breakers do not have provisions for
marking tags. A possible solution is to cut the adhesive
SchS2 tag rail to length (approximately 20 mm on a
single pole unit so the current rating remains visible or
approximately 30 mm on a two pole unit). The SchS2
accepts DEK, WS and ESG 8/17 marking tags. The
part number for adhesive SchS2 is 1720600000.

Type: Double Pole Aux

Current
Ratings
(amps) Part No.
1
9926262001
2
9926262002
5
9926262005
10 9926262010
15 9926262015
20 9926262020
25 9926262025

Type: Double Pole Trip

Description
QL-A-2-13-DM-KM-1
QL-A-2-13-DM-KM-2
QL-A-2-13-DM-KM-5
QL-A-2-13-DM-KM-10
QL-A-2-13-DM-KM-15
QL-A-2-13-DM-KM-20
QL-A-2-13-DM-KM-25

1000

Operating Characteristics
Curve KM

9926272005 QL-T-2-13-DM-KM-5
9926272010 QL-T-2-13-DM-KM-10
9926272015 QL-T-2-13-DM-KM-15
9926272020 QL-T-2-13-DM-KM-20
9926272025 QL-T-2-13-DM-KM-25

31.3
(1.23)

26.2
(1.03)

(N/O)16
(N/C)18
(C)15

Ambient Temperature 30C

TRIP ALARM Q. CONNECTORS

21.1
(0.83)

10

5.5
(0.22)
0.5
(0.02)

Tripping Time

Minutes

100

57.0
(2.24)

1
10

14(N/O)

21.3
(0.84)

(%) Rated Current

4000
5000

2000
2500
3000

1500

1000

400
500

300

0.001

32.9
(1.3)

10.7
(0.42)

0.5
(0.02)

0.1

100
105
125
150
200

7
(0.28)

2.8
(0.11)

11(C)

Seconds

12(N/C)

AUX SWITCH Q. CONNECTORS

0.01

Part No.
Description
9926272001 QL-T-2-13-DM-KM-1
9926272002 QL-T-2-13-DM-KM-2

Dual Mount Dimensions in mm (in.)

Trip CurvesHydraulic
Magnetic Type Typical
time/current characteristics
at 30C
Additional trip curves and
amp ratings are available
upon request.

Type: Double Pole Combo

Current
Ratings
(amps) Part No.
1
9926282001
2
9926282002
5
9926282005
10 9926282010
15 9926282015
20 9926282020
25 9926282025

2
(0.08)

9926 SeriesAC version Trip Curve

Current
Ratings
(amps)
1
2
5
10
15
20
25

Description
QL-AT-2-13-DM-KM-1
QL-AT-2-13-DM-KM-2
QL-AT-2-13-DM-KM-5
QL-AT-2-13-DM-KM-10
QL-AT-2-13-DM-KM-15
QL-AT-2-13-DM-KM-20
QL-AT-2-13-DM-KM-25

9 9 2 6 S e r i e s B r a n c h R a t e d C i rc u i t B re a k e r s D C Ve r s i o n
Circuit Breakers
Hydraulic Magnetic Type

9926 Series
Single Pole
(80 VDC)

9926 Series
Single Pole
(125 VDC)

Single pole versions only


U2 trip curve for general purpose
applications
80 and 125 VDC
Up to 60A
Just 13 mm wide
Mounts on 35mm DIN-rail
UL 489A listed
VDE
Type: Single Pole (80 VDC)

Current
Ratings
(amps)
0.5
1
2
3
4
5
10
15
20
25
30
35
40
45
50
60

Accessories

Part No.
9926251900

Description
QY-1-13-DM-U2-0.5

9926251901
9926251902

QY-1-13-DM-U2-01
QY-1-13-DM-U2-02

9926251903
9926251904
9926251905

QY-1-13-DM-U2-03
QY-1-13-DM-U2-04
QY-1-13-DM-U2-05

9926251910
9926251915

QY-1-13-DM-U2-10
QY-1-13-DM-U2-15

9926251920
9926251925
9926251930
9926251935
9926251940
9926251945
9926251950

QY-1-13-DM-U2-20
QY-1-13-DM-U2-25
QY-1-13-DM-U2-30
QY-1-13-DM-U2-35
QY-1-13-DM-U2-40
QY-1-13-DM-U2-45
QY-1-13-DM-U2-50

9926251960

QY-1-13-DM-U2-60

9926 SeriesDC version Trip Curve

QY-1-13-DM-U2-05-B1

9926251810

QY-1-13-DM-U2-10-B1

9926251815
9926251820
9926251825
9926251830
9926251835

QY-1-13-DM-U2-15-B1
QY-1-13-DM-U2-20-B1
QY-1-13-DM-U2-25-B1
QY-1-13-DM-U2-30-B1
QY-1-13-DM-U2-35-B1

9926251840
9926251845
9926251850
9926251860

QY-1-13-DM-U2-40-B1
QY-1-13-DM-U2-45-B1
QY-1-13-DM-U2-50-B1
QY-1-13-DM-U2-60-B1

74
(2.91)
66
(2.6)

13
(0.51)

92.8
(3.65)

28.5
(1.12)

57
(2.24)

Minutes

Ambient Temperature 30C

1
10

19
(0.75)
1

32
(1.26)
0.1

5
(0.2)

45
(1.77)
64.8
(2.55)

0.01

4000
5000

0.001
300

10,000 A
1500 V, 50/60 Hz
100 MM
10000
mechanical operations
Operating temperature
-40+65C
Wire size*
1-15A:
14 AWG min.,
10 AWG max.
20-25A:
10 AWG min.
Torque
20 in.-lb
Approval
UL 489A Listed, CE, VDE

9926251805

10

100
105
130
150
200

Interrupting capacity
Dielectric strength
Insulation resistance
Operating life

Tripping Time

80,125 VDC
0.5 A
60 A

QY-1-13-DM-U2-02-B1
QY-1-13-DM-U2-03-B1
QY-1-13-DM-U2-04-B1

Dimensions in mm (in.)

Operating Characteristics
Curve U2 DC
(4% Ripple Factor)

100

Seconds

minimum
maximum

9926251802
9926251803
9926251804

71.4
(2.81)

1000

Technical Data

2000
2500
3000

67101913

1500

Lock-out handle

Description
QY-1-13-DM-U2-01-B1

Additional trip curves and amp ratings


are available upon request.

1000

Part No.
67101904
67101973
67101960
67101961

Part No.
9926251801

Trip CurvesHydraulic
Magnetic Type Typical
time/current characteristics
at 30C

400
500

Type
Bus-bar (1 pole, insulated 1m)
Bus bar end cap, 1 pole
Power lug, straight
Power lug, 90

Voltage
Current

Type: Single Pole (125 VDC)

Current
Ratings
(amps)
1
2
3
4
5
10
15
20
25
30
35
40
45
50
60

17.9
(0.7)

Ordering Data

(%) Rated Current

*Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards.
The 9926 circuit breakers do not have provisions for
marking tags. A possible solution is to cut the adhesive
SchS2 tag rail to length (approximately 20 mm on a
single pole unit so the current rating remains visible or
approximately 30 mm on a two pole unit). The SchS2
accepts DEK, WS and ESG 8/17 marking tags. The
part number for adhesive SchS2 is 1720600000.

9 9 2 6 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s
Circuit Breakers
Hydraulic Magnetic Type

9926 Series
Single Pole

9926 Series
Double Pole

9926 Series
Triple Pole

AC Voltages 240/480V
Trip curve 2 for general purpose
applications
UL 1077 recognized
VDE, CSA, and CE Approved
Just 13 mm wide
Mounts to 35 mm DIN-rail
Factory fitted auxiliary or trip alarm
Single, double and triple pole versions
Ordering Data

Type: Single Pole

Current
Ratings
(amps)
1
2
3
4
5
6
8
10
15
20
25
35
40
50
60

Accessories

Part No.

Description

9926251501
9926251502

QZ-1-13-D-2-01
QZ-1-13-D-2-02

9926251503

QZ-1-13-D-2-03

9926251504
9926251505

QZ-1-13-D-2-04
QZ-1-13-D-2-05

9926251506
9926251508
9926251510
9926251515
9926251520

QZ-1-13-D-2-06
QZ-1-13-D-2-08
QZ-1-13-D-2-10
QZ-1-13-D-2-15
QZ-1-13-D-2-20

9926251525
9926251535
9926251540
9926251550
9926251560

QZ-1-13-D-2-25
QZ-1-13-D-2-35
QZ-1-13-D-2-40
QZ-1-13-D-2-50
QZ-1-13-D-2-60

Part No.

Description

9926252501
9926252502

QZ-2-13-D-2-01
QZ-2-13-D-2-02

9926252504

QZ-2-13-D-2-04

9926252505
9926252506

QZ-2-13-D-2-05
QZ-2-13-D-2-06

9926252510
9926252515
9926252520
9926252525
9926252530

QZ-2-13-D-2-10
QZ-2-13-D-2-15
QZ-2-13-D-2-20
QZ-2-13-D-2-25
QZ-2-13-D-2-30

9926252535
9926252540
9926252550
9926252560

QZ-2-13-D-2-35
QZ-2-13-D-2-40
QZ-2-13-D-2-50
QZ-2-13-D-2-60

Part No.

Description

9926253510
9926253515

QZ-3-13-D-2-10
QZ-3-13-D-2-15

9926253520

QZ-3-13-D-2-20

9926253525
9926253530

QZ-3-13-D-2-25
QZ-3-13-D-2-30

9926253540
9926253550
9926253560

QZ-3-13-D-2-40
QZ-3-13-D-2-50
QZ-3-13-D-2-60

65
(2.56)
13
(0.51)

60
(2.36)

26
(1.02)

39
(1.54)

92.8
(3.65)

25.9
(0.94)
45
(1.77)

13
(0.51)

63.8
(2.51)
73
(2.87)

Operating Characteristics
Curve 2

Minutes

100
Ambient Temperature 30C
10

1
10

0.1

0.01

(%) Rated Current

4000
5000

2000
2500
3000

1500

1000

0.001
400
500

The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive
SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or
approximately 30 mm on a two pole unit).The SchS2 accepts DEK, WS and ESG 8/17 marking tags.
The part number for adhesive SchS2 is 1720600000.

Additional trip curves and


amp ratings are available
upon request.

1000

300

*Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards.

9926 SeriesSupplemental Trip Curve

Trip CurvesHydraulic
Magnetic Type Typical
time/current characteristics
at 30C

100
105
130
150
200

Technical Data
Voltage
277/480 VAC @ 50/60 Hz
Current
minimum
0.5 A
maximum
60 A
Interrupting capacity
5 kA @ 277/480 V, 5 kA @ 120 V, 5 kA @ 240 V
Dielectric strength
1500 V, 50/60 Hz
Insulation resistance
100 MM
Operating life
10000 mechanical operations
Operating temperature
-40+65C
Wire size*
1-15A:
14 AWG min., 10 AWG max.
20-25A:
10 AWG min.
Torque
20 in.-lb
Approval
UL 1077 Recognized, VDE (EN 60947-2), CSA C22.2 No. 235, CE Approved

Tripping Time

5.0
(0.2)

13
(0.51)

Seconds

Part No.
67101904
67101972
67101971
67101973
67101974
67101960
67101961
67101913

44
(1.73)

Type: Triple Pole

Current
Rating
(amps)
10
15
20
25
30
40
50
60

9926 Series Supplemental dimensions in mm (in.)

22.5
(0.86)

Type
Bus bar (1 pole, insulated 1m)
Bus bar (2 pole, insulated 1m)
Bus bar (3 pole, insulated 1m)
Bus bar end cap, 1 pole
Bus bar end cap, 2 pole or 3 pole
Power lug, straight
Power lug, 90
Lock-out handle

Type: Double Pole

Current
Rating
(amps)
1
2
4
5
6
10
15
20
25
30
35
40
50
60

9 9 2 6 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s w i t h C o n t a c t s
Circuit Breakers
Auxiliary switch, Trip alarm,
Combination of both

9926 Series
Single Pole
w/ Auxiliary Contact

9926 Series
Single Pole Trip
(Alarm Contact)

9926 Series
Single Pole Combination
(Auxiliary & Alarm Contact)

AC Voltages 240/480V
Trip curve 2 for general purpose
applications
UL 1077 recognized
VDE, CSA, and CE Approved
Just 13 mm wide
Mounts to 35 mm DIN-rail
Factory fitted auxiliary or trip alarm
Single, double and triple pole versions
Type: Single Pole Aux

Technical Data
Voltage

277/480 VAC @ 50/60 Hz

Current
minimum

0.5 A

maximum

60 A

Interrupting capacity

5 kA @ 277/480 V,

5 kA @ 120 V, 5 kA @ 240 V
Dielectric strength
Insulation resistance
Operating life

1500 V, 50/60 Hz
100 MM
10000
mechanical operations

Operating temperature
-40+65C
Wire size*
1-15A:
14 AWG min., 10 AWG max.
20-25A:
10 AWG min.
Torque
20 in.-lb
Approval
UL 1077 Recognized, VDE (EN 60947-2),
CSA C22.2 No. 235, CE Approved

Current
Ratings
(amps)
1
2
5
10
15
20
25

Part No.
9926261501
9926261502

Description
QZ-A-1-13-D-2-01
QZ-A-1-13-D-2-02

9926261505
9926261510

QZ-A-1-13-D-2-05
QZ-A-1-13-D-2-10

9926261515
9926261520
9926261525

QZ-A-1-13-D-2-15
QZ-A-1-13-D-2-20
QZ-A-1-13-D-2-25

9926 Series
Double Pole
w/ Auxiliary Contact

Type: Single Pole Trip

Current
Ratings
(amps)
1
2
5
10
15
20
25

Part No.
9926271501
9926271502

Description
QZ-T-1-13-D-2-01
QZ-T-1-13-D-2-02

9926271505
9926271510

QZ-T-1-13-D-2-05
QZ-T-1-13-D-2-10

9926271515
9926271520
9926271525

QZ-T-1-13-D-2-15
QZ-T-1-13-D-2-20
QZ-T-1-13-D-2-25

9926 Series
Double Pole Trip
(Alarm Contact)

Type: Single Pole Combo

Current
Ratings
(amps)
1
2
5
10
15
20
25

Part No.
9926281501
9926281502

Description
QZ-AT-1-13-D-2-01
QZ-AT-1-13-D-2-02

9926281505
9926281510

QZ-AT-1-13-D-2-05
QZ-AT-1-13-D-2-10

9926281515
9926281520
9926281525

QZ-AT-1-13-D-2-15
QZ-AT-1-13-D-2-20
QZ-AT-1-13-D-2-25

9926 Series
Double Pole Combination
(Auxiliary & Alarm Contact)

*Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards.
The 9926 circuit breakers do not have provisions for
marking tags. A possible solution is to cut the adhesive
SchS2 tag rail to length (approximately 20 mm on a
single pole unit so the current rating remains visible or
approximately 30 mm on a two pole unit). The SchS2
accepts DEK, WS and ESG 8/17 marking tags.The
part number for adhesive SchS2 is 1720600000.

9926 SeriesSupplemental Trip Curve

Trip CurvesHydraulic
Magnetic Type Typical
time/current characteristics
at 30C
1000

Operating Characteristics
Curve 2

Type: Double Pole Aux

Current
Ratings
(amps)
1
2
5
10
15
20
25

Part No.
9926262501
9926262502
9926262505

Description
QZ-A-2-13-D-2-01
QZ-A-2-13-D-2-02
QZ-A-2-13-D-2-05

9926262510

QZ-A-2-13-D-2-10

9926262515
9926262520

QZ-A-2-13-D-2-15
QZ-A-2-13-D-2-20

9926262525

QZ-A-2-13-D-2-25

Type: Double Pole Trip

Current
Ratings
(amps)
1
2
5
10
15
20
25

Part No.
9926272501
9926272502
9926272505

Description
QZ-T-2-13-D-2-01
QZ-T-2-13-D-2-02
QZ-T-2-13-D-2-05

9926272510

QZ-T-2-13-D-2-10

9926272515
9926272520

QZ-T-2-13-D-2-15
QZ-T-2-13-D-2-20

9926272525

QZ-T-2-13-D-2-25

Type: Double Pole Combo

Current
Ratings
(amps)
1
2
5
10
15
20
25

Part No.
9926282501
9926282502
9926282505

Description
QZ-AT-2-13-D-2-01
QZ-AT-2-13-D-2-02
QZ-AT-2-13-D-2-05

9926282510

QZ-AT-2-13-D-2-10

9926282515
9926282520

QZ-AT-2-13-D-2-15
QZ-AT-2-13-D-2-20

9926282525

QZ-AT-2-13-D-2-25

Tripping Time

Minutes

100
Ambient Temperature 30C
10

9926 Series
Triple Pole
w/ Auxiliary Contact

1
10

9926 Series
Triple Pole Trip
( Alarm Contact)

9926 Series
Triple Pole Combination
(Auxiliary & Alarm Contact)

Seconds

0.1

0.01

4000
5000

2000
2500
3000

1500

1000

400
500

300

100
105
130
150
200

0.001

Type: Triple Pole Aux

(%) Rated Current

Current
Ratings
(amps)
1
2
5
10
15
20
25

Part No.
9926263501
9926263502
9926263505
9926263510
9926263515

Description
QZ-A-3-13-D-2-01
QZ-A-3-13-D-2-02
QZ-A-3-13-D-2-05
QZ-A-3-13-D-2-10
QZ-A-3-13-D-2-15

9926263520
9926263525

QZ-A-3-13-D-2-20
QZ-A-3-13-D-2-25

Type: Triple Pole Trip

Current
Ratings
(amps)
1
2
5
10
15
20
25

Part No.
9926273501
9926273502
9926273505
9926273510
9926273515

Description
QZ-T-3-13-D-2-01
QZ-T-3-13-D-2-02
QZ-T-3-13-D-2-05
QZ-T-3-13-D-2-10
QZ-T-3-13-D-2-15

9926273520
9926273525

QZ-T-3-13-D-2-20
QZ-T-3-13-D-2-25

Type: Triple Pole Combo

Current
Ratings
(amps)
1
2
5
10
15
20
25

Part No.
9926283501
9926283502
9926283505
9926283510
9926283515

Description
QZ-AT-3-13-D-2-01
QZ-AT-3-13-D-2-02
QZ-AT-3-13-D-2-05
QZ-AT-3-13-D-2-10
QZ-AT-3-13-D-2-15

9926283520
9926283525

QZ-AT-3-13-D-2-20
QZ-AT-3-13-D-2-25

9 9 2 6 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s G F C I
Ground Fault Current Interrupt

Ordering Data

QF17A2515
QF17A2520
QF17A2525
QF17A2530
QF17A2550

CB
CB
CB
CB
CB

W/GFI
W/GFI
W/GFI
W/GFI
W/GFI

Trip CurvesHydraulic Magnetic


Type Typical
time/current characteristics
at 30C
1000

2
-40 to +65C

Operating Characteristics
Curve 2

Tripping Time

Minutes

100

44
(1.73)

Ambient Temperature 30C


10

68.8
(2.71)

1
10

26
(1.02)
1

Seconds

Approval
UL 1077 and UL 1053, CE

73
(2.87)
65
(2.56)

0.1

7.8
(0.307)

5 to 50A

Sensitivity (mA)
30 (CE) / 22 (UL)
Number of Poles
1+N
Equipment Type
Earth Leakage/GFCS
Rated Voltage (V)
230 (CE) / 240 (UL)
Rated Interrupting/
5 kA
Withstand Capacity (kA)

Weight (kg)
0.26
Trip Curve (standard)
Operating Temperature

Description
QF17A2505 - CB W/GFI
QF17A2510 - CB W/GFI

9926 SeriesAC version Trip Curve

Technical Data
Standard Ampere Ratings (A)

9926 Series GFCI dimensions in mm (in.)

Type: Single Pole GFCI

Current
Ratings
(amps) Part No.
5
9926291105
10
9926291110
15
9926291115
20
9926291120
25
9926291125
30
9926291130
50
9926291150

4000
5000

2000
2500
3000

1500

1000

400
500

300

100
105
130
150
200

0.001

16.4
(0.646)

8.0
(0.315)

71.4
(2.81)

0.01

26
(1.02)

(2.24)

57

CE approved
UL1077 and UL1053 recognized
Small frame size (26mm wide)
Single pole plus switched neutral
earth leakage protection
Trip point is unaffected by ambient
temperature
Current ratings up to 50A
Trip indication
(mid trip handle position)
Trip curve 2 for general purpose
applications

93
(3.66)
82.4
(3.24)

9926 Series
GFCI

(%) Rated Current

35.7
(1.406)

9926 Series Mounting Options and Accessories


Mounting Options

93%

95

ON

OFF

95

OF
F

ON

OF
F

ON

5 N VERT 45
W

ON
OFF

100%

ON

VERT D 4
O

R
5 N HO IZ DO 4
W

10

ON
OF F

ON

OF
F

ON

OF
F

5%

100%

HORIZ 4
5

OFF

UP

UP

It is important to note that in environments that are exposed to


a high degree of vibration, the cables that connect to the circuit
breaker must be securely held in place, as the breaker is not
designed to carry the weight of the cables. A maximum of 35N
can be applied to the terminal area, in a direction perpendicular
to the mounting axis.

If the product is not vertically mounted in the normal DIN-rail


mounting orientation, a rating factor must be applied. Figure 1
shows a diagram of the rating factor to apply. The published
curves for these circuit breaker products are produced with
the circuit breaker in the vertical mounting position. The rating
factor only applies to the must hold and must trip points of the
curve as the other parts (instantaneous trip point) stay largely
unaffected.

10

107%
Accessories
Technical Data

Part Number Table - Example

Current Rating
Voltage
Short Circuit Strength

80A max.
500V max.
25kA

Type
Bus bar (1 pole, insulated 1m)
Bus bar (2 pole, insulated 1m)

Part No.
67101904
67101972

Bus bar (3 pole, insulated 1m)

67101971

To order 9926 Series Single Pole Circuit Breaker


Part No. 9926251100
Current Rating of 1.0 amp
Internal Resistance per Pole of 1.1 ohms
Trip Curve M1, Medium (Standard)

9 9 2 6 2 5 1 0 0 0
Amperage

Type
Bus bar end cap, 1 pole
Bus bar end cap, 2 pole or 3 pole

Part No.
67101973
67101974

"00" - 0.5A
"01" - 1A
"02" - 2A

/
"60" - 60A

Trip Curves
"0" - Branch AC KM (Standard)
"1" - Branch AC OP (Instantaneous)
"2" - Branch AC 1 (Fast)
"4" - Branch 80VDC 1 (Fast)
"5" - Supplemental 2 (Standard)
"6" - Branch 125VDC OP (Instantaneous)
"7" - Branch 80VDC OP (Instantaneous)
"8" - Branch 125VDC U2 (Standard)
"9" - Branch 80VDC U2 (Standard)

Poles

Technical Data
Current Rating
Wire Size
Dimensions

85A max.
10 AWG min., 4 AWG max.
A: 6 mm B: 32 mm

1 Pole
2 Pole
3 Pole

Type
Type
Power lug, straight
Power lug, 90

Part No.
67101960
67101961

Type
Lock-out handle

Part No.
67101913

"5" - Base Breaker


"6" - With Auxiliary Contact
"7" - With Trip Alarm Contact
"8" - Combo Aux/Trip Contact
"9" - GFCI