You are on page 1of 29

al Sanayi Blgesi narlk Cad.

No: 18-20 Nilfer - Bursa / TRKYE


Tel.
: 0090 224 411 11 84
Fax : 0090 224 411 11 86
E-mail : export@caldera.com.tr

BOILERS | WATER HEATERS | RADIATORS

CALDERA HEATING GROUP


Caldera was first established in 2004 as a distributor of towel radiators across Europe. Then, the company became
Caldera Heating Group with the addition of steel boiler production. Today, the company has expanded its organization
with the production of cast iron boilers, wood gasification boilers, and biomass (pellet) boilers, and the distribution of
.
other products such as gas fired water heaters, hot water cylinders, and design radiators.
Recently, Caldera Heating Group established its own sales, distribution, and after-sales service network in Turkey with
new products typical of this market such as automatic feeding boilers for small size coals and gas fired water heaters.
Caldera Heating Group exports its products to more than 23 countries around the world (especially to Europe), and
.
we're working to expand exports to different countries.
We use the latest technology in all of our products which are our own registered and approved designs. We strive to
.
develop the highest quality, environmentally friendly products.
Each welder in Caldera Heating Group is approved on EN ISO 287-1 as well as our own welding process. We use a
synergistic system that include MAG and TIG welding machines and the most advanced system for welding gas exhaust.
.
We also have our own combustion and research laboratory with and advanced data acquisition system.
All of our products are CE approved, and manufactured to meet or exceed European Community Directives and
.
relevant harmonized standards for each category.
Our goal is to provide the highest customer satisfaction by manufacturing and distributing the highest quality products
.
and providing the best service, and we plan to grow and prosper in this sector over the long term.
Our products today include:
- Steel boilers for solid fuels (natural draught and fan assisted models)
- Wood gasification boilers with pyrolytic combustion
- Cast iron boilers for solid fuels
- Biomass (pellet) boilers
- Cast Iron Radiators ( Victoria )
- Towel radiators
- Design radiators (stainless steel and aluminum)
- Gas fired water heaters
- Floor standing hot water cylinders
- Hot water cylinders with integrated wall-hanging electric heaters

steel boilers
for solid fuels

Compact and high efficiency solutions for manually loaded boilers


Suitable for firing wood logs, brown coal, and lignite
High heating surface and high fuel loading volume result in high efficiency and longer combustion periods

Caltherm S

Natural draught combustion controlled by primary air regulation via thermostatic controller
Manual adjustment on secondary air for better combustion and flue emissions
Easy loading and boiler cleaning due to properly sized front doors

High Efficiency Steel Boilers (Natural Draught)

Cast iron bottom grade for long operation life


Scaled thermometer to monitor boiler outlet temperature
Optional cooling loop for protection against over-heating
Reliable materials, approved production quality and good finishing

Up to 70 kW

CE approval on Pressure Equipment Directive (97/23/EC)

Manual loading
Three pass flue circulation
Models

Caltherm S

Types

CT 25 S

CT 35 S

CT 45 S

CT 55 S

17

25

35

45

55

70

14.600

22.000

30.000

40.000

48.000

60.000

58

66

75

85

105

120

kW

Output

kcal/h

Water Content

lt

Combustion chamber
dimensions

Height

mm

Width

mm

Depth

mm

Fuel loading clearance (upper door)

330

420
525

381
330 215

mmxmm

420 x 215

mm

400

30-90

Maximum operating temperature

100

Minimum return temperature

50 (recommended)

Maximum operating pressure

bar

Water flow/return connections (D)

Safety heat exchanger connection

Filling / draining connection

765
480 X 265

2,5
1"

1 "
1"
"

R
1090

1180

Height (H)

mm

H1

mm

H2

mm

H3

mm

1000

H4

mm

1125

Width (W)

mm

Length (L)

mm

490

630

730

870

L1

mm

630

770

870

1010

Flue outlet diameter (D)

mm

215
230

490

1100
1215
580

160

640

180

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

L1

W
D

R 1

H3

D
D

H1

H2

External dimensions

480
621

Temperature control range

Max. Fuel loading height (for log wood)

CT 70 S

490

H4

Technical Data

CT 17 S

Compact solutions for manually loaded boilers, ideal for DIY and wholesaler channels
Suitable for firing wood logs, brown coal, and lignite
High heating surface and high fuel loading volume result in high efficiency and longer combustion periods

Caltherm Basic

Natural draught combustion controlled by primary air regulation via thermostatic controller
Easy loading and boiler cleaning due to properly sized front doors
Cast iron bottom grade for long operation life

Medium Efficiency Steel Boilers (Natural Draught)

Scaled thermometer to monitor boiler outlet temperature


Optional cooling loop for protection against over-heating
Reliable materials, approved production quality and good finishing

Up to 45 kW

CE approval on Pressure Equipment Directive (97/23/EC)

Manual loading
Models

Caltherm Basic

Types

CT 28 B

CT 35 B

23

28

35

45

20.000

24.000

30.000

40.000

68

75

85

95

525

620

kW

Output

kcal/h

Water Content

lt

Combustion chamber
dimensions

Height

mm

Width

mm

Depth

mm

Fuel loading clearance (upper door)

375
370

430
375 x 280

mmxmm
mm

400

Temperature control range

30 to 90

Maximum operating temperature

100

Minimum return temperature

50 (recommended)

Maximum operating pressure

bar

2,5

Max. Fuel loading height (for log wood)

Water flow/return connections (D)

2"

Safety heat exchanger connection

1 "

Filling / draining connection

CT 45 B

480

"

R
Height (H)

mm

1073

H1

mm

190

H2

mm

320

H3

mm

985

H4

mm

1093

Width (W)

mm

Length (L)

mm

460

523

623

718

L1

mm

610

588

688

783

Flue outlet diameter (D)

mm

530

160

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

L1

W
D

D
G

R 1

D
H3

D
R

H2

External dimensions

H4

Technical Data

CT 23 B

H1

Two pass flue circulation

Caltherm F
High Efficiency Steel Boilers (Fan Assisted Combustion)

High efficiency solutions for manually loaded boilers

Room thermostat option

Suitable for firing wood logs, brown coal, and lignite

Operation status and fault indicators

Optional cooling loop for protection against over-heating

Auto switch-off when there is no fuel

Reliable materials, approved production quality and good finishing

Night and ECO modes to save energy

CE approval on Pressure Equipment Directive (97/23/EC)

Adjustable flue damper on smokehood

Energy saving and safety features due to programmed PCB

Cast iron bottom grade for long operation life

Easy loading and boiler cleaning due to properly sized front doors
Stylish electronic control board with well organized function buttons and big LCD screen
High heating surface and high fuel loading volume result in high efficiency and longer combustion periods

Up to 70 kW

Fan assisted combustion with modulation on motor speed enables operation at poor chimney installations

Manual loading
Models

Caltherm F

Types
kcal/h

Water Content

45

55

70

22.000

30.000

40.000

48.000

60.000

80

90

108

72

450

Width

mm

330

420

420

480

480

Depth

mm

525

525

621

621

765

mmxmm

420 x 215

330215

480 X 365

400

mm
C

Maximum operating temperature

100

Minimum return temperature

40 (recommended)

Maximum operating pressure

bar

500

1 "

1 "

2,5

Water flow/return connections (D)

Connec. for safety inlet/outlet (d g,dd)

1"

Safety heat exchanger connection

1"

Filling / draining connection

1"

1"

1"

"

Height (H)

mm

1090

H1

mm

840

H2

mm

375

1180

260

930

H3

mm

H4

mm

Width (W)

mm

W1

mm

Length (L1)

mm

1110

1210

1350

L2

mm

640

740

880

L3

mm

Flue outlet diameter (D)

245
580

490

mm

640

180

160

180
230/50

V/Hz
82

88

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

L1
L2
W1

L3

W
D

102

D
G

d
g

d
d
R
D
D
H2
H3

Power consumption

450
50 to 90

Temperature control range

Electrical supply

124

475

mm

Max. Fuel loading height (for log wood)

External dimensions

CT 70 F

Height

Fuel loading clearance (upper door)

Technical Data

CT 55 F

35

lt

Combustion chamber
dimensions

and safety features

CT 45 F

25

kW

Output

Sophisticated energy saving

CT 35 F

Electronic control

CT 25 F

H1

Fan speed modulation

Caltherm XF

High efficiency solutions for manually loaded boilers

Operation status and fault indicators

Suitable for firing wood logs, brown coal, and lignite

Auto switch-off when there is no fuel

Cast iron bottom grade for long operation life

Night and ECO modes to save energy

CE approval on Pressure Equipment Directive (97/23/EC)

Room thermostat option

Energy saving and safety features due to programmed PCB

Adjustable flue damper on smokehood

Reliable materials, approved production quality and good finishing

High Efficiency Steel Boilers for Central Heating systems


(Fan Assisted Combustion)

Stylish electronic control board with well organized function buttons and big LCD screen
Manually activated auto ash-discharge mechanism with movable cast iron bottom grates (only for 90 and 115 kw)
High heating surface and high fuel loading volume result in high efficiency and longer combustion periods
Fan assisted combustion with modulation on motor speed enables operation at poor chimney installations

Up to 290 kW

Easy loading and boiler cleaning due to properly sized and separated front loading and cleaning doors

Manual loading
Electronic control with fan speed modulation
Models

Caltherm XF

Types
kW

Output

kcal/h

Water Content

lt

Combustion chamber
dimensions

Height

mm

Width

mm

Depth

mm

CTX 150 F

CTX 175 F

CTX 200 F

90

115

145

175

200

230

290

80.000

100.000

125.000

150.000

175.000

200.000

250.000

258

325

400

420

474

546

221
550

Maximum operating temperature

Minimum return temperature

Maximum operating pressure

bar

Water flow/return connections (D)

Connec. for safety inlet/outlet (d g,dd)

Filling / draining connection

830

CTX 250 F

580
760

920

1130

1140

1330

550 x 285

550 x 320

690x280

550

600

580

mm

Temperature control range

600
550

710

mmxmm

Max. Fuel loading height (for log wood)

50 to 90
100
40 (recommended)
3,2
1"

2"

2"

3"

1 "

"

R
Height (H)

mm

H1

mm

310

H2

mm

335

H3

mm

Width (W)

mm

W1

mm

Length (L1)

mm

1420

1530

1640

1860

1420

1530

1640

L2

mm

860

980

1060

1280

860

980

1060

L3

mm

1100

1220

1350

1454

1100

1220

1350

Flue outlet diameter (D)

mm

Electrical supply
Power consumption

1400

1400

1625

1625

1715

1815

1815

485
770

940

825

200

220

260
230/50

V/Hz

230

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

L1
L2
L3
W

DG

dg

dd
DD

R 3/4"

H2
H3

External dimensions

CTX 125 F

H1

Technical Data

Fuel loading clearance (upper door)

CTX 100 F

H4

Auto ash-discharge mechanism

CTX 80 F

Sophisticated energy saving and safety features

High efficiency solutions for manually loaded boilers

Room thermostat option

Particular secondary air distribution on top of combustion chamber

Full three-pass circulation

Energy saving and safety features due to programmed PCB

Operation status and fault indicators

Caltherm KF

Particular front doors for loading and cleaning.

Auto switch-off when there is no fuel

Energy saving and safety features due to programmed PCB

Night and ECO modes to save energy

Movable cast iron bottom grade for long operation life

Adjustable flue damper on smokehood

High Efficiency Steel Boilers


(Fan Assisted Combustion)

Manually activated auto ash discharge mechanism


Stylish electronic control board with well organized function buttons and big LCD screen
Fan assisted combustion with modulation on motor speed enables operation at poor chimney installations
Suitable for firing wood logs, standard and smal size (< 20 mm) brown coal and lignite, small size coal with dust inside

Up to 70 kW
Manual loading

High heating surface and smoke tube design with integrated fume retarders on third passage result in high efficiency
Long combustion periods due to increased combustion chamber volume (up to 2 days with one full loading when fired with small size coals)

Fan speed modulation


Models

Caltherm KF

Types
kW

Output

kcal/h

Water Content

lt

Combustion chamber
dimensions

Height

mm

Width

mm

Depth

mm

by particular secondary
Fuel loading clearance (upper door)

45

55

70

30.000

40.000

48.000

60.000

95

114

85
420

480

525

621

621
480 x 300

500

600
50 to 90

Maximum operating temperature

100

Minimum return temperature

40 (recommended)

Maximum operating pressure

bar

Connec. for safety inlet/outlet (d g,dd)

Filling / draining connection

2,5
1"

1 "
1"
"

R
1340

1455

Height (H)

mm

H1

mm

145

H2

mm

270

H3

mm

Width (W)

mm

590

W1

mm

900

Length (L1)

mm

940

1040

1180

L2

mm

800

900

1040

L3

mm

640

740

Flue outlet diameter (D)

mm

Electrical supply

480
650
960

180
230/50

V/Hz

Power consumption

880

160
85

200

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

L1
L

W1
W
101

D
G

d
g

d
d
D
D
R

H1

External dimensions

765

420 x 260

mm

136
600

Temperature control range

Water flow/return connections (D)

CT 60 KF

550

mmxmm

Max. Fuel loading height (for log wood)

Technical Data

air distribution

CT 48 KF

35

H3

and coal+dust mixtures

CT 40 KF

Ideal for small size coals,

CT 30 KF

H2

Electronic control

Caltherm SF

Adjustable flue damper on smokehood

ECO and Night modes

Easy operation and cleaning, high comfort

Room thermostat option

Optional cooling loop for protection against over-heating

Large volume for fuel storage

Combustion fan speed modulation via programmed PCB

Auto switch-off when there is no fuel

Magnetic protection on motor of automatic feeding system

Operation status and fault indicators

Energy saving and safety features due to programmed PCB

Manual ignition (optional auto ignition)

Reliable materials, approved production quality and good finishing

Automatic Feeding Boilers For Walnut-Coals And Pirina


(Fan Assisted Combustion)

Stylish electronic control board with well organized function buttons and big LCD screen
Automatic feeding and firing of walnut coal (up to 20 mm), walnut shell, pirina and pellets
High heating surface results in higher efficiency among similar products found in the market
Prismatic full three pass flue circulation with smoke tubes integrated with special design fume retarders

Up to 115 kW

Detachable high grade cast iron burner system which is the first application in the field saves on service work

Electronic control with fan speed modulation


Sophisticated energy saving and safety features
Models

Caltherm CT SF

Types
kW

Output

kcal/h

Water Content
Coal

Fuel Hopper Capacity

CT 40 SF

CT 60 SF

CT 80 SF

30

45

70

90

115

25.000

40.000

60.000

80.000

100.000

140

170

180

lt

72

100

kg

105

120

kg

90

100

130
44 to 90 (factory settings)

Temperature control range

Maximum operating temperature

100

Minimum return temperature

40 (recommended)

Maximum operating pressure

bar

3
1

Water flow/return connections (D)


Connec. for safety inlet/outlet (d g,dd)

R
R

Filling / draining connection

1325

Height (H)

mm

H1

mm

H2

mm

343

H3

mm

511

Width (W)

mm

600

600

632

718

W1

mm

1100

1100

1180

1270

Length (L1)

mm

1160

1260

1310

1410

L2

mm

1005

1110

1160

1260

L3

mm

810

890

940

1040

Flue outlet diameter (D)

mm

160

Electrical supply

1155

1240
328

1160

180
230/50

V/Hz

Power consumption (continiously feeding)

460

600

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

L1
W
D

DG

L2
L3
dg

dd
DD
H1
H2

H3

W1
101

External dimensions

CT 100 SF

155

Technical Data

Olive Pomace

CT 25 SF

dol.
bo.

Caltherm XSF
Medium Range Automatic Feeding Boilers
For Walnut-Coals And Pirina
(Fan Assisted Combustion)
Up to 290 kW
Electronic control with fan speed modulation

Manual ignition
Auto switch-off when there is no fuel
ECO and Night modes
Easy operation and cleaning, high comfort
Room thermostat option
Adjustable flue damper on smokehood
Large volume for fuel storage
Magnetic protection on motor of automatic feeding system
Operation status and fault indicators
Combustion fan speed modulation via programmed PCB
Energy saving and safety features due to programmed PCB
Reliable materials, approved production quality and good finishing
Stylish electronic control board with well organized function buttons and big LCD screen
Automatic feeding of walnut coal (up to 20 mm), walnut shell, pirina (olive seed) and pellets
High heating surface results in higher efficiency among similar products found in the market
Prismatic full three pass flue circulation with smoke tubes integrated with special design fume retarders
Detachable high grade cast iron burner system which is the first application in the field saves on service work

Sophisticated energy saving and safety features

Models

Caltherm CT XSF

Types
kW

Output

kcal/h

Water Content

lt

CTX 175 SF

CTX 200 SF

145

175

200

230

290

125.000

150.000

175.000

200.000

250.000

400

420

474

595

325

CTX 250 SF

mm

230

300

360

Olive Pomace

mm

195

260

310

Temperature control range

Maximum operating temperature

Minimum return temperature

Maximum operating pressure

bar

Water flow/return connections (D)


Connec. for safety inlet/outlet (d g,dd)

44 to 90 (factory settings)
100
40 (recommended)
3,2
2"

Filling / draining connection

3"

R
1625

1815

Height (H)

mm

H1

mm

308

H2

mm

333

H3

mm

Width (W)

mm

750

935

W1

mm

1355

1540

Length (L1)

mm

1465

1685

1790

1960

L2

mm

1300

1520

1610

1780

L3

mm

1030

1250

1250

Flue outlet diameter (D)

mm

Electrical supply

1715

483

280
380 V / 50 Hz

V/Hz

Power consumption (continiously feeding)

1420

220
1730

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

L1

W1
D

101
d

L2
L3
d
g
D
G

R 3/4"

D
D
H3
H2
H1

Technical Data

CTX 150 SF

Coal

Fuel Hopper Capacity

External dimensions

CTX 125 SF

Caltherm MF
High Range Manual Feeding Steel Boiler
(Fan Assisted Combustion)
Up to 700 kW
Electronic control with fan speed modulation

Room thermostat option


Operation status and fault indicators
Auto switch-off when there is no fuel
Easy operation and cleaning, high comfort
Adjustable flue damper on smoke hood
Large fuel loading clearance and combustion chamber
High-quality thermal isolation materials in boiler covers
Reliable materials, approved production quality and good finishing
Adjustable flue damper helps to adjusting combustion rate according to draft
Stylish electronic control board with well-organized function buttons and big LCD screen
Complete combustion is performed by properly dimensioned surfaces and combustion air
High heating surface results in higher efficiency among similar products found in the market
Cylindrical full three pass flue circulation with smoke tubes integrated with special design fume retarders

Sophisticated energy saving and safety features

Models

Caltherm MF

Types

CT 350 MF

CT 400 MF

CT 450 MF

CT 500 MF

350

400

465

525

580

700

300.000

350.000

400.000

450.000

500.000

600.000

1050

1365

1500

1740

1920

2360

kW

Output

kcal/h

Water Content

lt

Combustion Chamber Dim.

940

mm

()
Width

mm

1350

1720

1880

1720

1880

2280

50 - 90

Maximum operating temperature

100

Minimum return temperature

40 (recommeded)

Maximum operating pressure

bar

Optional, from 3 bar to 5 bar

Water flow/return connections (D)

3"

Connec. for safety inlet/outlet (dg,dd)

1 "

Filling / draining connection

External Dimensions

CT 600 MF

1040

Temperature control range

4"
2"
1"

Heigth (H)

mm

2170

2410

H1

mm

1825

2005

H2

mm

92

92

H3

mm

500

560

H4

mm

540

810

Width (W)

mm

1375

1535

Depth (L1)

mm

2300

2670

2830

2670

2830

3230

L2

mm

1980

2350

2510

2350

2510

2910

L3

mm

1395

1770

1925

1770

1925

2325

L4

mm

1770

2145

2300

2145

2300

2700

Flue outlet diameter (D)

mm
V/Hz
W

Electrical supply
Power consumption -except pump-

400

500
400/50
755

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

L1
L2
W

L3
d
g

154

d
d

D
D

H2

L4

H3

H4

H1

Technical Data

CT 300 MF

Caltherm MSF
High Range Automatic Feeding Boilers
For Walnut-Coals And Pirina
(Fan Assisted Combustion)
Up to 700 kW
Electronic control with fan speed modulation

Large volume for fuel storage


High heating surface results in higher efficiency among similar products found in the market
Detachable high grade burner system which is the first application in the field saves on service work
Magnetic protection on motor of automatic feeding system
Stylish electronic control board with well-organized function buttons and big LCD screen
Operation status and fault indicators
Energy saving and safety features due to programmed PCB
Auto switch-off when there is no fuel
ECO and Night modes
Room thermostat option
Easy operation and cleaning, high comfort
Adjustable flue damper on smoke hood
Reliable materials, approved production quality and good finishing

Sophisticated energy saving and safety features

Models

Caltherm MSF

Types
kW

Output

kcal/h

Water Content

lt

Fuel Hopper Capacity

lt

CT 350 MSF

CT 400 MSF

CT 450 MSF

CT 500 MSF

350

400

465

525

580

700

300.000

350.000

400.000

450.000

500.000

600.000

1050

1365

1500

1740

1920

2360

1720

1880

470
940

mm

()
Depth

mm

1350

1040

1720

1880

Maximum operating temperature

100

Minimum return temperature

40 (recommeded)

Maximum operating pressure

bar

Optional, from 3 bar to 5 bar

Water flow/return connections (D)

3"

Connec. for safety inlet/outlet (dg,dd)

1 "

Filling / draining connection

4"
2"
1"

mm

2170

2410

H1

mm

1825

2005

H2

mm

92

92

H3

mm

510

510

Heigth (H)

2280

50 - 90

Temperature control range

External Dimensions

CT 600 MSF

H4

mm

760

740

Width (W)

mm

1375

1535

2470

2730

W1

mm

Depth (L1)

mm

2300

2670

2830

2670

2830

3230

L2

mm

1980

2350

2510

2350

2510

2910

L3

mm

1395

1770

1925

1770

1925

2325

Flue outlet diameter (D)


Distance must be applied between hopper
and internal wall
Electrical supply
Power consumption -except pump(continiously feeding)

mm

400

mm

2000

500
2100
400/50

V/Hz

2255

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

L1
L2

W1

L3
D

124

d
g

800

H1

900
d
d

H2

H3

H4

1660

Technical Data

Combustion Chamber Dim.

CT 300 MSF

D
D
d dol
bos

gasification
boilers

Megatherm Plus
High Efficiency Wood Gasification Boilers
(Fan Assisted Combustion)

CE approval on Pressure Equipment Directive (97/23/EC)

Room thermostat option

Integrated cooling loop for protection against over-heating

Primary and secondary air regulation

Energy saving and safety features due to programmed PCB

Operation status and fault indicators

Suction fan assisted combustion with modulation on motor speed

Auto switch-off when there is no fuel

Auto switch to fan maximum speed when loading door is opened

Reduced polluting emissions, small quantity of ash,

Additional thermostat for DHW storage tank and outlet for DHW pump

Pyrolytic combustion, suitable for firing dry wood logs

High quality steel in boiler construction, durable materials on burner and ash pan
Stylish electronic control board with well organized function buttons and big LCD screen
New suction fan with higher flow rate and new fan housing with vertical flue outlet result in better performance and minimized smoke loss
New and larger fuel loading chamber with good resistance to condensation with integrated new by-pass zone (fuel loading capacity

Up to 70 kW
Manual loading

increased by 15%)
High efficiency due to fully watercooled smokehood behind fuel loading chamber (total active heating surface increased by 8% compared
to Megatherm)

Exhaust fan speed modulation

Temperature control range


Maximum operating temperature
Minimum return temperature
Safety system activated at
Maximum operating pressure
Water flow/return connections
Cooling loop connections
Filling / draining connection
External dimensions
Height (H)
H1
H2
H4
Width (W)
Length (L1)
Length (L2)
Flue outlet diameter (D)

Allowable wood log size


Maximum wood log length

MTP 32

18

25

32

85
2,4
82,0

120
2,9
116,0

210,0

105
2,7
102,0
1150
200,0

g/s
Pa
mbar
C
C
C
C
bar
R
R
R

17,0
15 - 20
0.15 - 0.20

23,6
20 - 30
0.2 - 0.3

30,2
22 - 32
0.22 - 0.32

mm
mm
mm
mm
mm
mm
mm
mm

1155
70
200
1075
615
1180
790

MTP 50

MTP 70

MTP 100

50

70

100

165
4,0
193,0

205
4,7
275,0

240
6,5
275,0

210,0

215,0

215,0

47,1
28 - 38
0.28 - 0.38

66,0
30-40
0,30-0,40

66,0
30 - 40
0.30 - 0.40

2000

1 1/2"

2"
3/4"
1/2"

38

1155
70
200
1075
615
1300
910

38

cm

200,0

Megatherm Plus
1783 - PED - 028
MTP 40
Wood logs
40
80
145
3,6
163,0
1525
200,0
3
37,8
25 - 35
0.25 - 0.35
60 - 90
100
60 (recommended)
95
3

45,0

55,0

1155
70
200
1075
615
1400
1010
159
38

1265
70
200
1185
680
1400
1010

1265
70
200
1185
680
1475
1140

1365
70
200
1285
680
1660
1285

1520
70
200
1485
680
1740
1285
180

230 V / 50 Hz
48

48

Wood logs
6 to 8
Allowable water content 12 - 20%
Average calorific value 15.000 - 17.000 kJ/kg
Diameter between 7 cm - 15 cm
65,0
65,0
75,0

48

48

92,0

92,0

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

L1
L2

W
D

R 1 1/2"

R3/4"

Fuel type
Combustion period at max load
Requested fuel parameters

kW
%
lt
m2
dm3
cm2
C

MTP 25

H4

Electrical supply
Power consumption

MTP 18

R
1
1/
R

2"

1/
2"

H2

Technical Data

Improved design with additional features

Model
CE Identification number
Ranges
Fuels
Output
Efficiency
Water content
Total heating surface
Fuel container volume
Fuel loading clearance (upper door)
Flue gas temperature
CO emission class
Flue gas mass flow
Required draft at chimney

H1

Electronic control

Integrated cooling loop for protection against over-heating

Buffer probe

Manually activated new smoke by-pass section with minimized loss

Three-way valve option

Large and prismatic fuel loading particularly sized for better gasification process

Auto switch-off when there is no fuel

Pyrocal

High quality steel in boiler construction, durable materials on burner and ash pan

Room thermostat connection

Reduced polluting emissions, small quantity of ash ( CO less than EN 303/5 class 3)

CE approval on Pressure Equipment

CE approval on EN 303/5 Class 3 Pyrolytic combustion, suitable for firing dry wood logs

Directive (97/23/EC)

High Efficiency Wood Gasification Boilers


(Fan Assisted Combustion)

Stylish electronic control board with well organized function buttons and big LCD screen
New suction fan with interated fan housing with vertical flue outlet results in better performance
High efficiency due to increased and smoke tubed water heating surfaces (over EN 303/5 class 3)
Operation status and fault indicators, energy saving and safety features due to programmed PCB
Exhaust fan assisted combustion with modulation on motor speed enables good performance even with old chimney installations
in fuel loading chamber

Model
CE Identification number
Ranges
Fuels
Output
Efficiency
Water content
Total heating surface
Fuel container volume
Fuel loading clearance (upper door)
Flue gas temperature
CO emission class
Flue gas mass flow
Required draft at chimney
Temperature control range
Maximum operating temperature
Minimum return temperature
Safety system activated at
Maximum operating pressure
Water flow/return connections
Cooling loop connections
Filling / draining connection
External dimensions
Height (H)
H1
H2
H3
H4
Width (W)
Length (L1)
Length (L2)
Flue outlet diameter (D)
Electrical supply
Power consumption
Fuel type
Combustion period at max load
Requested fuel parameters

22

30

85
2,4
85,0
190,0

105
2,7
105,0
1230
190,0

g/s
Pa
mbar
C
C
C
C
bar
R
R
R

17,0
15-20
0.15 - 0.20

23,6
20 - 30
0.2 - 0.3

mm
mm
mm
mm
mm
mm
mm
mm
mm

1170
110
195
880
830
612
1050
770

1170
110
195
880
830
612
1170
885
159

1170
110
195
880
830
612
1270
990

38

38

38

PYR 80

60

80

165
4,0
200,0
220,0

205
6,0
285,0
2140
220,0

47,1
28 - 38
0.28 - 0.38

66,0
30-40
0,30-0,40

1650
200,0
210,0
EN 303 - 5 CLASS 3
30,2
37,8
22 - 32
25 - 35
0.22 - 0.32
0.25 - 0.35
60 - 90
100
60 (recommended)
95
3
1 1/2"
3/4"
1/2"

2"

1270
110
195
980
960
672
1270
990

1270
110
195
980
960
672
1350
1070

1380
110
195
1045
1040
672
1575
1260
180

48

48

75,0

92,0

168
230 V / 50 Hz

Wood logs
6 to 8
Allowable water content 12 - 20%
Average calorific value 15.000 - 17.000 kJ/kg
Diameter between 7 cm - 15 cm
65,0
65,0

cm

45,0

48

55,0

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

L1
w

L2
R1 1/2"
R 3/4 "

H
H4

Allowable wood log size


Maximum wood log length

kW
%
lt
m2
dm3
cm2
C

PYR 60

R1 1/2"
R 1/2"
H2

Technical Data

Improved design with additional features

Pyrocal
1783 - PED - 028
PYR 38
PYR 48
Wood logs
38
48
EN 303 - 5 CLASS 3
120
145
2,9
3,6
120,0
170,0

PYR 30

Electronic control

PYR 22

75

Exhaust fan speed modulation

H3

Manual loading

Effective primary and secondary air regulation with good combustion air distribution result in high gasification and low condensation rate

H1

Up to 80 kW

Integra

CE approval on Pressure Equipment Directive (97/23/EC)

Room thermostat connection

New burner design with good combustion air distribution

Auto switch-off when there is no fuel

Integrated cooling loop for protection against over-heating

Primary and secondary air regulation

Additional thermostat for DHW storage tank and outlet for DHW pump

New by-pass principle with minimized smoke loss

Three front doors for better ignition, operation and cleaning of the boiler

Pyrolytic combustion, suitable for firing dry wood logs

Reduced polluting emissions, small quantity of ash ( CO less than EN 303/5 class 5)
Stylish electronic control board with well organized function buttons and big LCD screen

New Generation Wood Gasification Boilers


(Fan Assisted Combustion)

Auto activation of exhaust fan to maximum speed when door is open to minimize smoke loss
Operation status and fault indicators, energy saving and safety features due to programmed PCB
High efficiency due to increased and smoke tubed water heating surfaces ( over EN 303/5 class 5 )
Large fuel loading chamber with dry internal surface particularly sized for better gasification process

Dry internal surface by double wall in fuel loading chamber, results in less condensation rate and better boiler protection, as well as higher
gasification ratio and easier surface cleaning

Model
CE Identification number
Ranges
Fuels
Output
Water content
Total heating surface
Fuel container volume
Fuel loading clearance (upper door)
Flue gas temperature
CO emission class
Flue gas mass flow
Required draft at chimney
Temperature control range
Maximum operating temperature
Minimum return temperature
Safety system activated at
Maximum operating pressure
Water flow/return connections
Cooling loop connections
Filling / draining connection
External dimensions
Height (H)
H1
H2
H3
H4
Width (W)
Length (L1)
Length (L2)
Flue outlet diameter (D)
Electrical supply
Power consumption
Fuel type
Combustion period at max load
Requested fuel parameters

ITG 32

ITG 40

kW
lt
m2
dm3
cm2
C

25
90
2,74
106,7

40
110
3,83
187,8

210,0

32
100
3,05
128,5
1120
200,0

g/s
Pa
mbar
C
C
C
C
bar
R
R
R

17,0
15 - 20
0.15 - 0.20

23,6
20 - 30
0.2 - 0.3

mm
mm
mm
mm
mm
mm
mm
mm
mm

1440
125
380
900
1335
586
860
1180

ITG 50

ITG 70

ITG 100

50
132
5,04
304,9

70
170
7,15
402,9
1650
210,0

100
215
10,00
520,0

47,1
28 - 38
0.28 - 0.38

66,0
30 - 40
0.30 - 0.40

Wood logs

200,0
200,0
PrEN 303/5:2011 Class 5
30,2
37,8
22 - 32
25 - 35
0.22 - 0.32
0.25 - 0.35
65 - 90
100
65 (recommended)
95
3

215,0

1 1/2"

2"
3/4"
1/2"

1440
125
380
900
1335
586
960
1280

3/4"

1540
125
380
1000
1435
586
1110
1430

1660
125
380

1740
125
380

1840
125
370

1555
666
1210
1530

1655
666
1360
1680

1742
666
1510
1865

159

180
230 V / 50 Hz

110

cm

45,0

55,0

330
Wood l ogs
6 to 8
Allowable water content 12 - 20%
Average calorific value 15.000 - 17.000 kJ/kg
Diameter between 7 cm - 15 cm
70,0
80,0

95,0

110,0

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

L2

R 1 1/2"

L1
D

R 3/4"

R 1 1/2"
R 1/2"

H1

Allowable wood log size


Maximum wood log length

Integra
1783 - PED - 028
ITG 25

81

Technical Data

High efficiency and low polluting emissions

H2

Exhaust fan speed modulation

H4

Manual loading

Exhaust fan assisted combustion with modulation on motor speed enables good performance even with old chimney installations

H3

Electronic control

New suction fan with higher flow rate and new fan housing with vertical flue outlet result in better performance

Up to 100 kW

steel hot water boilers


for gas, oil or dual
fuel burners

Caltech 3

Stainless steel fume retardes in third passage smoke tubes

High efficieny ( 2 stars ),

Available for forced draught gas or oil burners, dual fuel burners.

Prismatic external design,

Suitable for hot water heating circuits and low temperature systems,

Compact dimensions due to cylindrical body design,

Building cascade systems up to 5 boilers, and zone control solutions

Front door available for both left or right side hinging

Full three pass circulation principle results in low particul emissions at flue outlet
Smooth operation due to properly sizing of combustion chamber and flue passages,
Good combustion results due to lowered heat input rate inside combustion chamber,

Steel Boilers
For Forced Draught Burners

Integration for building automatization systems, management of modulation burners


Standard production for 3 bars operating pressure, higher operating pressures available upon request
High quality in front door refractory design and body insulation boards result in minimized stand-by loses,
Long operation life thanks to good material used in construction and minimized themal stresses inside boiler body

Up to 1200 kW
Full three pass circulation

Control panel alternatives from basic two stage burner control to full automatic control with outside temperature compensation
Non-condensing operation for low temperature heating systems, thanks to special design for mixing return water and hot water
inside boiler at boiler inlet area

Compact dimensions
High efficiency
Model

Fill/drain
(FD)
3/4"

Flue
(D)
(mm)
200

Flue gas Water side


resistance resistance
H (mm) H1 (mm) W (mm) L (mm)
(mbar)
(mbar)
1005
690
875
1110
0,55
1,8
External Dimensions

TH3 80

93

50

1 1/4"

3/4"

200

1005

690

875

1340

0,65

2,2

TH3 100

116

50

1 1/4"

3/4"

200

1005

690

875

1640

0,75

2,8

TH3 150

175

65

1 1/4"

3/4"

200

1140

825

1010

1655

0,80

4,0

TH3 200

232

65

1 1/4"

3/4"

200

1140

825

1010

1955

0,95

5,0

TH3 250

290

65

1 1/4"

3/4"

300

1215

850

1085

1955

1,15

6,5

TH3 300

350

80

1 1/4"

3/4"

300

1240

925

1160

1955

1,20

8,0

TH3 350

407

80

1 1/4"

3/4"

350

1385

1050

1285

1960

1,60

10,0

TH3 400

465

80

1 1/2"

1"

350

1385

1050

1285

2160

1,80

11,0

TH3 450

525

100

1 1/2"

1"

350

1485

1150

1385

2160

2,30

12,0

TH3 500

580

100

1 1/2"

1"

350

1485

1150

1385

2360

2,50

15,0

TH3 600

700

100

1 1/2"

1"

400

1635

1300

1540

2560

2,80

15,0

TH3 700

815

125

2"

1"

400

1685

1350

1660

2660

3,10

16,5

TH3 800

930

125

2"

1"

450

1835

1500

1750

2760

3,50

18,0

TH3 900

1050

125

2"

1"

450

1885

1500

1800

2860

3,70

19,0

TH3 1000

1165

125

2"

1"

450

1935

1550

1850

2960

4,00

20,0

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

H1

Technical Data

TH3 60

Rated Flow/return Safety


output
(F/R)
(S)
(kW)
DN
70
50
1 1/4"

FD

Suitable for hot water and low temperature heating installations

biomass
boilers

Bio-Pack ES & EX
Compact pellet boilers

Auto switch-off when there is no fuel

Automatic ignition

Fire protection system, safety against back burning

Room thermostat control option

Low polluting emissions (less than eN 303/5 Class 4)

High water efficiency (above 85%)

Two models with different features and control options

PID control, adjustable boiler outputs

Very compact dimensions to match any installation space


High heating surface with vertical flue circulation principle
Exhuast fan speed control via encoder ensures a very safe operation
Burner made of special stainless steel sheetmetal with high heat resistance

Up to 40 kW

Exhaust fan speed modulation in respect with desired outlet water temperature and flue gas temperature

Automatic ignition
Very compact dimensions

Technical Data

High efficiency

Model
Fuels
Output
Efficiency
Flue circulation
Draught
Maximum operating temperature
Maximum operating pressure
Water flow/return connections
Filling / draining connection
Burner design
Fuel container capacity
External dimensions

BP 18
kW
%

18

C
bar
G
G
kg
W
H
H1
H2
H3
L
L1
D

mm
mm
mm
mm
mm
mm
mm
mm

BP 24
Wood pellets 6 - 8 mm
24
EN 303/5 Class 4
Vertical
Exhaust fan at flue outlet
100
3
1 " (male)
1/2" (male)
Stainless steel pot

45

BP 32

BP 40

32

40

52

75

90

1490
1365
1210

1600
1450
1310

730

900

1365
1240
1085
325
545
520

1700
1550
1410
375
600
580

128

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

BIOPACK
EX
YES
YES
YES
YES
AUTOMATIC
YES
YES
YES
YES
YES

USER INTERFACE

Electronic ignition
PID control
Exhaust fan speed modulation
Exhuast fan operation control (encoder)
Burner cleaning
Smoke tube cleaning (manual activation)
Smoke tube cleaning (automatic)
Fire protection
Flue thermostat
Outdoor temperature sensor
Room thermostat connection

BIOPACK
ES
YES
YES
YES
YES
MANUAL
YES
YES
YES
NO
YES

L1

FEATURES

OUTPUTS*

D
D

YES
YES
NO
NO

* Outputs refer to system capability, accessories are not included in delivery

YES
YES
YES
YES

H3

Central heating pump


Buffer tank
3-way valve
DHW pump

H2

H1

D
G

cast iron boilers


for solid fuels

Solitherm S

Suitable for firing wood logs, brown coal, lignite, and coke

Scaled thermometer to monitor boiler outlet temperature

High heat transfer rate due to finned design of cast iron sections,

Optional cooling loop for protection against over-heating

Compact and high efficiency solutions for manually loaded boilers

CE approval on Pressure Equipment Directive (97/23/EC)

Water-cooled bottom grate for easy warm-up period and high energy
Manual adjustment on secondary air for better combustion and flue emissions
Natural draught combustion controlled by primary air regulation via thermostatic controller

High Efficiency Cast Iron Boilers For Solid Fuels


(Natural Draught)

EN-GJL 200 grade grey cast iron made boiler body, approved production quality and good finishing
Advanced flue gas circulation with high efficiency due to new patented flue gas circulation by Caldera,
High corrosion resistance and long operation life due to flexible casting technology and cast iron boiler elements
Faster fire-up intervals between fuel re-loads due to easy access of air inside combustion chamber, thanks to vertical finned combustion

Up to 56 kW

chamber surfaces,

Manual loading
New and modern design
Solitherm S

Model

Patented flue gas circulation principle

Types

ST 3 S

Number of sections

27

34

41

48

56

(Wood) kW

15

23

30

36

43

51

lt

27

32

37

42

52

52

520

620

720

mm
mm

Depth

mm

425
315
220

320

420
322 x 318

mmxmm

mm

400

Temperature control range

50 - 90

Maximum operating temperature

100

Minimum return temperature

50 (recommended)

Maximum operating pressure

bar

Water flow/return connections (D)

1 "

Filling / draining connection

"

Length (L1)

mm

525

625

725

825

925

1025

L2

mm

380

480

580

680

780

880

Flue outlet diameter (D)

mm

160

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

L1

530

L2

R 1 1/2"

180
205

R 1 1/2"

R 1/2"

890

735

970

External dimensions

ST 8 S

Width

Max. Fuel loading height (for log wood)

ST 7 S

17

Height

Fuel loading clearance (upper door)

ST 6 S

pcs.

1050

Technical Data

Combustion chamber
dimensions

ST 5 S

(Coal) kW

Nominal Power
Water Content

ST 4 S

CE approval on Pressure Equipment Directive (97/23/EC)

Room thermostat option

Suitable for firing wood logs, brown coal, lignite, and coke

Operation status and fault indicators

Energy saving and safety features due to programmed PCB

Auto switch-off when there is no fuel

Solitherm F

High heat transfer rate due to finned design of cast iron sections,

Night and ECO modes to save energy

Compact and high efficiency solutions for manually loaded boilers

Optional cooling loop for protection against over-heating

High Efficiency Cast Iron Boilers For Solid Fuels


(Fan Assisted Combustion)

Stylish electronic control board with well organized function buttons and big LCD screen

Water-cooled bottom grate for easy warm-up period and high energy
EN-GJL 200 grade grey cast iron made boiler body, approved production quality and good finishing
Advanced flue gas circulation with high efficiency due to new patented flue gas circulation by Caldera,
High heating surface and high fuel loading volume result in high efficiency and longer combustion periods
Fan assisted combustion with modulation on motor speed enables operation at poor chimney installations

Up to 70 kW
Manual loading

High corrosion resistance and long operation life due to flexible casting technology and cast iron boiler elements
Faster fire-up intervals between fuel re-loads due to easy access of air inside combustion chamber, thanks to vertical finned combustion
chamber surfaces,

Electronic control with fan speed modulation


New and modern design
Patented flue gas circulation principle

Solitherm F

Model

Types
Number of sections

Nominal Power

Combustion chamber
dimensions

ST 6 F

ST 7 F

ST 8 F

ST 10 F

pcs.

10

(Coal) kW

34

41

48

56

70

(Wood) kW

30

36

43

51

65

lt

27

32

37

42

52

720

920

Height

mm

Width

mm

Depth

mm

Fuel loading clearance (upper door)

425
315
420

520

620
322 x 318

mmxmm

Max. Fuel loading height (for log wood)

400

mm

50 - 90

Temperature control range

Maximum operating temperature

100

Minimum return temperature

50 (recommended)

Maximum operating pressure

bar

Water flow/return connections (D)


Filling / draining connection

740

Length (L1)

mm

725

825

925

1025

1225

L2

mm

580

680

780

880

1080

Flue outlet diameter (D)

mm

160
230/50

V/Hz

43

82

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

W
L1

530

L2

R 1 1/2"

R 1/2"

890

735
205

R 1 1/2"

180

Power consumption

670

mm

Electrical supply

"

R
Width (W)

100

External dimensions

4
1 "

970

Technical Data

Water Content

ST 5 F

radiators

Elegance look of its classic styling ideal for both traditional and contemporary buildings
Radiant Heat combined with convected heat provides a warm comfortable environment

Victoria

It performs as a shield for cold air coming from outside walls and windows

Cast Iron Radiator

Available in and two heights 600mm and 800mm.

The advantages of slow cooldown ensure extended warming time.

Durable cast iron prevents the product from denting, bending and coming apart for years.

Maximum efficiency
Excellent heat transfer properties

Pressure tested ready for plumbing into your new or existing heating system.
Coloured with primary coating RAL 7022.

Unique high quality old fashioned castiron radiator


Long lasting usage

Type

Name

Distance
Height Between Width
(mm) Center (mm)
(mm)

Water
Content
(I)

Weight
(kg)

Heating
Nipple
Surface
(inch)
(m2)

Heat
Heat
Heat
Output* Output* Output*
(W)
(kcal/hr) (BTU/hr)

Victoria

600

Feet

770

600

225

3,2

11,7

1" 1/4

0,31

147

126

500

Victoria

600

Middle

710

600

225

3,2

10,6

1" 1/4

0,31

147

126

500

Victoria

800

Feet

970

800

225

14,6

1" 1/4

0,47

227

195

774

Victoria

800

Middle

910

800

225

13,5

1" 1/4

0,47

227

195

774

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

225

111

111

800

600

225

772

972

Technical Data

Easy installation

L = 760 for 10 sections

250

L = 760 for 10 sections

250

Polo

E Type

Stainless Steel Design Radiators

Stainless Steel Design Radiators

Technical Data

Technical Data

Polo

Height
mm

Width
mm

Depth
mm

Center to
Center

Center
to Wall

Polo 09656-15

986

560

50

420

95-110

Front to Number KCal Watts


Wall of Tubes ? 50C ? 50C
412
479
127-142 15+2

Polo 15056-23

1486

560

50

420

95-110

127-142

23+2

631

734

Kind of Tubes
40x10+32
40x10+32

E-type

Height
mm

Width
mm

Depth
mm

Center to
Center

Center
to Wall

E-type

975

800

75

80

95-110

Front to Number
KCal Watts
Wall
of Tubes
? 50C ? 50C
135-150
18+2
670
780

Kind of Tubes
40x20+40x40

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

Zephyr

Cadence

Stainless Steel Design Radiators

Stainless Steel Design Radiators

Technical Data

Technical Data
Height
mm

Width
mm

Depth
mm

Center to
Center

Cadence 70B11

700

510

65

510

Center Back to Front to Number


KCal Watts
to Wall Wall
Wall of Tubes
? 50C ? 50C
100-115 75-90 125-140
575
668
11

Cadence 100B10

1000

465

65

465

100-115 75-90 125-140

10

746

867

50x30

1500

510

65

510

100-115 75-90 125-140

11

1231

1431

50x30

Zephyr

Height
mm

Width
mm

Depth
mm

Center to
Center

Center
to Wall

Front to
Wall

Number
of Tubes

Zephyr 100-10

1000

490

30

450

95-110

105-120

10

40x10+40x20

Zephyr 200-05

2000

240

30

200

95-110

105-120

490

570

40x10+40x20

Zephyr 200-10

2000

490

30

450

95-110

105-120

10

1023 1140

40x10+40x20

Cadence 150B11

KCal Watts
? 50C ? 50C
490 570

Kind of Tubes

Cadence B

Kind
of Tubes
50x30

Caftan

Dora

Stainless Steel Design Radiators

Aluminum Design Radiators

Technical Data

Technical Data

Caftan

Height
mm

Width
mm

Depth
mm

Center to
Center

Center Front to Number


to Wall
Wall of Tubes

Caftan 345

790

500

45

380

95-110 105-120

12

Caftan 456

940

500

45

380

95-110 105-120

15

KCal Watts
? 50C ? 50C
294
342
367

427

Kind of Tubes

Dora

Height
mm

Width
mm

Depth
mm

Center to
Center

Center Front to Number


to Wall
Wall of Tubes

40x10+40x20

Dora

1500

280

31

140

75-90

110-130

40x10+40x20

Dora

2000

280

31

140

75-90

105-120

15

KCal Watts
? 50C ? 50C
354
412
473

550

* Caldera Heating Group reserves the right to make changes on product dimensions and general view without prior notice

Impulse

Excel

Stainless Steel Design Radiators

Aluminum Design Radiators

Technical Data

Technical Data

Impulse

Height
mm

Width
mm

Depth
mm

Center to
Center

Impulse 100

1000

460

57

414

Center Front to Number KCal Watts


to Wall
Wall
of Tubes ? 50C ? 50C
775
95-110 137-152 10+2
667

Impulse 150

1500

460

57

414

95-110 137-152

10+2

1000

1163

Impulse 200

2000

460

57

414

95-110 137-152

10+2

1333

1550

Kind of Tubes

Excel

Height
mm

Width
mm

Depth
mm

Center to
Center

D32-32

Excel 55ALW110-12

550

1100

115

1037

Serbest Serbest

24

D32-32

Excel 55AL160-12

550

1600

115

1537

Serbest Serbest

12

D32-32

Center Front to Number


to Wall
Wall of Tubes

KCal Watts
? 50C ? 50C
804
936
1206

1404

Caltherm White

Caltherm Chrome

White Towel Radiators

Chrome Towel Radiators

Caltherm Chrome / Technical Data

Caltherm White / Technical Data


Heat Output

White Towel Radiators


Model

Width
(mm)

Height
(mm)

407
408
410
411
412
414
416
418

400
400
400
400
400
400
400
400

700
800
1000
1100
1200
1400
1600
1800

Connection
Axis
(mm)
355
355
355
355
355
355
355
355

507
508
510
511
512
514
516
518

500
500
500
500
500
500
500
500

700
800
1000
1100
1200
1400
1600
1800

607
608
610
611
612
614
616
618

600
600
600
600
600
600
600
600

700
800
1000
1100
1200
1400
1600
1800

White / Straight

Heat Output

Chrome Towel Radiators

White / Curve

Connection
Pipe
Tubes
Axis
Quantity Diameter
(mm)

Chrome / Straight

Chrome / Curve

Water
Content

Heating
Surface
(m2)

Weight
(kg)

kcal/h

watt

kcal/h

watt

13
14
16
18
20
24
27
32

22
22
22
22
22
22
22
22

2,67
3,00
3,50
3,90
4,30
5,10
5,80
6,70

Heating
Surface
(m2)
0,46
0,50
0,65
0,67
0,80
0,94
1,07
1,24

455
455
455
455
455
455
455
455

13
14
16
18
20
24
27
32

22
22
22
22
22
22
22
22

3,00
3,40
4,00
4,40
4,90
5,80
6,60
7,70

0,55
0,64
0,76
0,80
0,94
1,11
1,26
1,46

4,20
4,70
5,60
6,10
6,80
8,10
9,20
10,60

308
349
411
452
503
596
678
768

358
406
478
526
585
693
789
893

310
352
414
455
507
600
683
770

361
409
481
529
590
698
794
896

507
508
510
511
512
514
516
518

500
500
500
500
500
500
500
500

700
800
1000
1100
1200
1400
1600
1800

455
455
455
455
455
455
455
455

13
14
16
18
20
24
27
32

22
22
22
22
22
22
22
22

3,00
3,40
4,00
4,40
4,90
5,80
6,60
7,70

0,55
0,64
0,76
0,80
0,94
1,11
1,26
1,46

4,20
4,70
5,60
6,10
6,80
8,10
9,20
10,60

216
244
288
316
352
417
474
538

251
284
335
368
409
485
551
626

217
246
290
319
355
420
478
539

252
286
337
371
413
488
556
627

555
555
555
555
555
555
555
555

13
14
16
18
20
24
27
32

22
22
22
22
22
22
22
22

3,50
3,80
4,40
5,00
5,60
6,60
7,50
8,70

0,64
0,74
0,87
0,92
1,07
1,28
1,44
1,68

4,80
5,40
6,30
7,00
7,80
9,20
10,40
12,10

359
390
452
513
575
678
770
886

418
454
526
597
669
789
896
1030

362
393
455
517
579
683
776
888

421
457
529
601
673
794
902
1033

607
608
610
611
612
614
616
618

600
600
600
600
600
600
600
600

700
800
1000
1100
1200
1400
1600
1800

555
555
555
555
555
555
555
555

13
14
16
18
20
24
27
32

22
22
22
22
22
22
22
22

3,50
3,80
4,40
5,00
5,60
6,60
7,50
8,70

0,64
0,74
0,87
0,92
1,07
1,28
1,44
1,68

4,80
5,40
6,30
7,00
7,80
9,20
10,40
12,10

252
273
316
359
403
474
539
620

293
317
368
418
469
551
627
721

253
275
319
362
406
478
543
622

294
320
371
421
472
556
632
723

Pipe
Tubes
Quantity Diameter

Water
Content

Weight
(kg)

kcal/h

watt

kcal/h

watt

Model

Width
(mm)

Height
(mm)

3,60
4,00
4,80
5,30
5,90
7,00
7,90
9,10

274
308
359
401
429
524
596
644

319
358
418
466
499
609
693
749

276
310
362
404
432
528
600
646

321
361
421
470
502
614
698
751

407
408
410
411
412
414
416
418

400
400
400
400
400
400
400
400

700
800
1000
1100
1200
1400
1600
1800

355
355
355
355
355
355
355
355

13
14
16
18
20
24
27
32

22
22
22
22
22
22
22
22

2,67
3,00
3,50
3,90
4,30
5,10
5,80
6,70

0,46
0,50
0,65
0,67
0,80
0,94
1,07
1,24

3,60
4,00
4,80
5,30
5,90
7,00
7,90
9,10

192
216
252
280
300
367
417
451

223
251
293
326
349
427
485
525

193
217
253
282
302
369
420
452

224
252
294
328
351
429
488
526

* Caldera Heating Group reserves the rihgt to make changes on product dimensions and general view without prior notice