ULTRASONIC FLOW TRANSMITTER

INSTRUMENT DATA SHEET

Brief Description:

ULTRASONIC FLOW TRANSMITTER

Electrical Class: Class I, Div I, Grp D, T3

Total Qty:

Flow Meter
Type

Ultrasonic Flowmeter

Sensor type

Clamp On / Insertion Type ( Note - 9

Material of Construction
Body

SS316

Sensor Material

SS316L

Accuracy required

1% or better

Repeatability

0.3 % or Better

Enclosure

EExd

Ingress Protection

IP-65

Transmitter
Mounting Type

Integral/Separate

Enclosure

Exd

Ingress Protection

IP-65

Output Signal ( For Volumetric Flowrate )

4-20 mA,SMART/HART

Output Signal ( For Mass Flowrate )

Pulse Output

Supply Voltage

110 (10%) VAC, 50 (3%) Hz

Cable Entry

1/2"NPT (F)

Display

Housing

Die cast Alumnium

Options
Straighteners/ End Connection & Material

( Note- 10 )

Notes:
1

Vendor must fill in information marked (*) thus and return.

Internal test reports shall be submitted to purchaser before inspection call.

P&ID Numbers shall be read with prefix "J97-ONGC-SMS-ND-"

SS 316 Nameplate permanently fastened to the body shall be provided by vendor specifying its TAG NO., Manufacture, Model No. & Serial No.

Transmitter shall be supplied with all mounting accessories including cable glands, SS316 plugs, U Clamp & Fasteners.

Flange facing finish shall be 125 AARH

Transmitter shall be certified for Enclosure Protection by a statutory body and certificate for the same shall be provided.

All Spare Cable Entries shall be provide with Blind Plugs of Material SS 316

Vendor shall confirm mounting arrangement of the Sensor.

10

Vendor shall confirm minimum Straight Length Required for the Instrument on the Upstream as well as Downstream side based on which client sha
requirement of Flow Straighteners / Conditioners.

11

The process data given in this datasheet is taken from the datasheeet given by Heater treator vendor through E-Mail dated 8 - July - 2013.

Rev No.

Date

Description

Prpd By

Chkd By

1
2
3
4
5
6
7

onic Flowmeter

sertion Type ( Note - 9)

9
10
11
12

1% or better

13

3 % or Better

14
15
16
17
18

gral/Separate

19
20
21

A,SMART/HART

22

ulse Output

23
24

%) VAC, 50 (3%) Hz

/2"NPT (F)

25
26

cast Alumnium

27
28
29

Note- 10 )

30
31
32
33
34
35

del No. & Serial No.

36
37
38
39
40
41
42

sed on which client shall confirm the

43
44

- July - 2013.

45
46
47
48
49
50
51
52
53
54
55
56
57
58
59

Chkd By

Appd By

60

ULTRA SONIC FLOW TRANSMITTER


INSTRUMENT DATA SHEET

General
Tag number
P & ID No. (Note-3)
Quantity
Service / Location
Line Size & End connection
Manufacturer
Transmitter Model No.
Meter Model No.

Service Condition ( Note - 11 )


Process Fluid
Fluid State
Flowrate (Max / Norm / Min), kg/h
Op. Temp (Max / Norm / Min), C
Op. Press (Max / Norm / Min), kg/cm2g
Density, kg/m3
Viscosity, cP
Molecular Weight
Compressibility Factor
Specific Heat Ratio, Cp/Cv
Pressure Drop Allowable, kg/cm2
Actual Pressure Drop, kg/cm2

Flow Element & Transmitter


Connection size
End Connection (Note-6)
Calibration range, kg/h

FT-3064A
JBS-PRO-A2-3019, Sh 1
1
Crude Oil outlet
4" 150#
*
*
*

27582.2

Crude Oil
Liquid
24134.4
70/50/40
2.0/1.9/1.8
754.7
1.78
250.1
N.A
1.05
0.25
*

4"

6895.5

FT-3064B
JBS-PRO-A2-3019, SH2
1
Crude Oil outlet
4" 150#
*
*
*

FT-5064A
ND-PRO-A3-5025, Sh 1
1
Crude Oil outlet
2" 150#
*
*
*

FT-5064B
ND-PRO-A3-5025, Sh 2
1
Crude Oil outlet
2" 150#
*
*
*

Crude Oil
Liquid
24134.4
70/50/40
2.0/1.9/1.8
754.7
1.78
250.1
N.A
1.05
0.25
*

Crude Oil
Liquid
7585
70/50/40
2.0/1.9/1.8
754.7
1.78
250.1
N.A
1.05
0.25
*

Crude Oil
Liquid
7585
70/50/40
2.0/1.9/1.8
754.7
1.78
250.1
N.A
1.05
0.25
*

27582.2

6895.5

8718.5

2179.6

8718.5

4"

2"

2"

150#RF

150#RF

150#RF

150#RF

0-35000

0-35000

0-10000

0-10000

2179.6

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41

You might also like