ADR155c

ADR155c
Software Upgrade Procedure
to Release P5.7.0

266711804.doc
Issue 2 - 29/08/2011

CONTENTS

1 Introduction............................................................................................................................3
2 Before Installing....................................................................................................................5
3 Upgrade Procedure..............................................................................................................6
3.1 Release P5.3.3 to P5.7.0....................................................................................................6
3.1.1 ADR155c software installation.............................................................................6
3.2 Release P5.4.1 to P5.7.0..................................................................................................10
3.2.1 ADR155c software installation...........................................................................10
3.3 Release P5.4.5 to P5.7.0..................................................................................................14
3.3.1 ADR155c software installation...........................................................................14
3.4 Release P5.4.6 to P5.7.0..................................................................................................18
3.4.1 ADR155c software installation...........................................................................18
3.5 Release P5.5.0 to P5.7.0..................................................................................................22
3.5.1 ADR155c software installation...........................................................................22
3.6 Release P5.6.0 to P5.7.0..................................................................................................26
3.6.1 ADR155c software installation...........................................................................26
3.7 Release P5.6.1 to P5.7.0..................................................................................................29
3.7.1 ADR155c software installation...........................................................................29

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

2 / 22

266711804.doc
Issue 2 - 29/08/2011

1 Introduction
This note defines the procedure for upgrading the ADR155c software to the Release P5.7.0.

Warning : The ADR155c equipment at a release lower than P5.3.3 cannot be upgrading directly to the
release P5.7.0. It must be upgraded to the release P5.3.3 before realizing this procedure.
For upgrading the ADR155c to the relesase P5.3.3, see the document
"ADR155c Software Upgrade Procedure to Release P5.3.3".
The tables below provide a list of the software changes per release:
Software

Old Code (Release P5.3.3)

FPGA Pack
GFP150 board Application
(ADRGFP150)
Motherboard Application

252 689 520AB-ue

New Code
(Release P5.7.0)
253 349 071AA-we

251 863 036AJ-nc

251 863 036AK-of

252 689 517AC-mu

3 000 297 311-sa

Upgrading the GFP150 (ADRGFP150) board's software application causes a traffic interruption
while the new software is integrated. (60 seconds max.).
Upgrading the Motherboard software application doesnt cause a traffic interruption during the
reboot of the equipment.
Note: Beginning from P5.4.6 version, 4E/FE board can support jumbo frame function. In P5.7.0 version, to
use this feature, it is necessary to do No service then Service the 4E/FE board after the upgrade.
The operation of No service then Service causes atrafficinterruption of 4E/FE board. (60
seconds max.).
Software
FPGA Pack
GFP150 board Application
(ADRGFP150)
Motherboard Application

Old Code
(Release P5.4.1)
252 860 667AA-vm

New Code
(Release P5.7.0)
253 349 071AA-we

251 863 036AJ-nc

251 863 036AK-of

252 860 654AA-ni

3 000 297 311-sa

Upgrading the GFP150 (ADRGFP150) board's software application causes a traffic interruption
while the new software is integrated. (60 seconds max.).
Upgrading the Motherboard software application doesnt cause a traffic interruption during the
reboot of the equipment.
Note: Beginning from P5.4.6 version, 4E/FE board can support jumbo frame function. In P5.7.0 version, to
use this feature, it is necessary to do No service then Service the 4E/FE board after the upgrade.
The operation of No service then Service causes atrafficinterruption of 4E/FE board. (60
seconds max.).
Software
FPGA Pack
GFP150 board Application
(ADRGFP150)
Motherboard Application

Old Code
(Release P5.4.5)
252 860 667AA-vm

New Code
(Release P5.7.0)
253 349 071AA-we

251 863 036AK-oe

251 863 036AK-of

3 000 297 311-og

3 000 297 311-sa

Upgrading the GFP150 (ADRGFP150) board's software application causes a traffic interruption
while the new software is integrated. (60 seconds max.).
Upgrading the Motherboard software application doesnt cause a traffic interruption during the
reboot of the equipment.
Document SAGEMCOM - Reproduction et divulgation interdites
SAGEMCOM document - Reproduction and disclosure prohibited

3 / 22

266711804.doc
Issue 2 - 29/08/2011

Note: Beginning from P5.4.6 version, 4E/FE board can support jumbo frame function. In P5.7.0 version, to
use this feature, it is necessary to do No service then Service the 4E/FE board after the upgrade.
The operation of No service then Service causes atrafficinterruption of 4E/FE board. (60
seconds max.).
Software
FPGA Pack
GFP150 board Application
(ADRGFP150)
Motherboard Application

Old Code
(Release P5.4.6)
252 860 667AA-vm

New Code
(Release P5.7.0)
253 349 071AA-we

251 863 036AK-oe

251 863 036AK-of

3 000 297 311-ol

3 000 297 311-sa

Upgrading the GFP150 (ADRGFP150) board's software application causes a traffic interruption
while the new software is integrated. (60 seconds max.).
Upgrading the Motherboard software application doesnt cause a traffic interruption during the
reboot of the equipment.
Software
FPGA Pack
GFP150 board Application
(ADRGFP150)
Motherboard Application

Old Code
(Release P5.5.0)
253 209 235AA-wc

New Code
(Release P5.7.0)
253 349 071AA-we

251 863 036AK-oe

251 863 036AK-of

3 000 297 311-pd

3 000 297 311-sa

Upgrading the GFP150 (ADRGFP150) board's software application causes a traffic interruption
while the new software is integrated. (60 seconds max.).
Upgrading the Motherboard software application doesnt cause a traffic interruption during the
reboot of the equipment.
Note: In P5.7.0 version, it is necessary to do No service then Service the 4E/FE+1GE board after the
upgrade. The operation of No service then Service causes atrafficinterruption of 4E/FE+1GE board.
(60 seconds max.).
Software
GFP150 board Application
(ADRGFP150)
Motherboard Application

Old Code
(Release P5.6.0)

New Code
(Release P5.7.0)

251 863 036AK-oe

251 863 036AK-of

3 000 297 311-qe

3 000 297 311-sa

Upgrading the GFP150 (ADRGFP150) board's software application causes a traffic interruption
while the new software is integrated. (60 seconds max.).
Upgrading the Motherboard software application doesnt cause a traffic interruption during the
reboot of the equipment.
Software
Motherboard Application

Old Code
(Release P5.6.1)
3 000 297 311-rb

New Code
(Release P5.7.0)
3 000 297 311-sa

Upgrading the Motherboard software application doesnt cause a traffic interruption during the
reboot of the equipment.
Note: In P5.7.0 version, it is necessary to do No service then Service the GFP150 board after the
upgrade. The operation of No service then Service causes atrafficinterruption of GFP150 board. (60
seconds max.).

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

4 / 22

266711804.doc
Issue 2 - 29/08/2011

2 Before Installing

Check that all ADR155c equipment to be upgraded are accessible and aren't in written session.

Check that all ADR155c equipment to be upgraded are without alarms. In the opposite case,
process them before realizing this procedure.

Check that boards are inserted in all configured slots.

Check that the Tftpd32 application is started on the IONOS NMS TFTP server.

If the MSP 1+1 protection is used, check that the traffic is on the working path then
deactivate the MSP 1+1 protection for each equipment to be upgraded of the STM1 section.

Note the TFTP server address.

The following files are available:


- Fpga56we.gz
- Gfp150of.gz
- Adr570sa.gz

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

5 / 22

266711804.doc
Issue 2 - 29/08/2011

3 Upgrade Procedure
3.1 Release P5.3.3 to P5.7.0
3.1.1 ADR155c software installation
ADR155c upgrade:
Software (*)
Old Code
Motherboard Boot
252 165 976AC-ec
Motherboard Application
252 689 517AC-mu
FPGA Pack
252 689 520AB-ue
GFP150 board Application
251 863 036AJ-nc
(ADRGFP150)
(*): Modified software appears in Bold type

New Code (*)


252 165 976AC-ec
3 000 297 311-sa
253 349 071AA-we
251 863 036AK-of

No STM1DUAL4G,STM1DUAL5G,STM1SFP4G,STM1SFP5G,4E/FE+1GEand
GFP150(253243224Borupper)board must be inserted into the shelf before starting the upgrade
procedure.

Upgrade procedure with HTTP and a TFTP server for FPGA Pack as well as GFP150
(ADRGFP150) and Motherboard software Application:
- Copy the files Fpga56we.gz, Gfp150of.gz and Adr570sa.gz into the reference (root)
directory of the TFTP server. ( IONOS NMS installation directory \tftproot)
- For each ADR155c in the network:
Start HTTP on the ADR155c to be upgraded.
Select the Equipment\Up and Download\Download menus then enter the TFTP server
address under TFTP Server .
Fill the File description and select the Type of Downloaded Informations .
- Download FPGA Pack
: File Fpga56we.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 45 seconds per intermediate
equipment).
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations .
- Download Motherboard Application code
: File Adr570sa.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 2 minutes per intermediate
equipment).
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations .
- Download GFP150 (ADRGFP150) Application code : File Gfp150of.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 1 minute per intermediate
equipment).
Use the Switching menu to check the version of the downloaded codes.
(Select the menu then Switching )
Document SAGEMCOM - Reproduction et divulgation interdites
SAGEMCOM document - Reproduction and disclosure prohibited

6 / 22

266711804.doc
Issue 2 - 29/08/2011

Switch (Switch command) the GFP150 (ADRGFP150) Code.


Validate the warning message.
The traffic of GFP150 (ADRGFP150) board isnt interrupted while this command is
executed.
Select the Reload menu then check the switch of GFP150 (ADRGFP150) Code.
Switch (Switch and Reset command) the Motherboard Code.
This causes a hot reset.
Validate the warning message.
The traffic of GFP150 (ADRGFP150) board is interrupted while this command is
executed. (60 seconds max.).
The traffic of other accesses isnt interrupted while this command is executed.
Re-log on to the equipment with HTTP.
Use the Download menu to check that the Motherboard code has been switched.
(Menus : Up and Download\Download )
In the Download menu, fill the File description and select
the Type of Downloaded Informations (Second download) :
- Download FPGA Pack
: File Fpga56we.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 45 seconds per intermediate
equipment).
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations (Second download) :
- Download Motherboard Application code
: File Adr570sa.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 2 minutes per intermediate
equipment).
Select the Reload menu then check the downloaded code.
The Motherboard codes (current) and (reserve) are the same reference.
If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment
concerned.
If 4E/FE board(s) is(are) configured in the equipment, to use the Jumbo Frame function,
it is necessary to do No Service then Service every board.
(Select the 4E/FE board then the menu : Service )
The traffic of 4E/FE board(s) is interrupted while this command is executed.
(60 seconds max.).
Upgrade procedure with IONOS NMS and a TFTP server for FPGA Pack as well as
GFP150 (ADRGFP150) and Motherboard software Application:
Note: With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be
beforehand downloaded by HTTP in the equipment.
With IONOS NMS P4.4 or higher, the FPGA Pack (File: Fpga56we.gz) can be
downloaded by IONOS NMS.

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

7 / 22

266711804.doc
Issue 2 - 29/08/2011

- Copy the files Fpga56we.gz (with IONOS NMS P4.4 or higher), Gfp150of.gz and
Adr570sa.gz into the directory on the hard disk of the PC. (For example: C:\ADR155c).
- Display the Software Management window.
(In the menu bar of the Manager, select the menus: Tools \ Software Management ).
- Choose the Update mode to download the new software.
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Select select the soft type: ADRGFP board and the switch type: Switch and Reset.
- Select the file Gfp150of.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
- Click the Switch button to switch the Current and Reserve software.
The result displays in the Status column.
With IONOS NMS P4.3 or lower, the traffic of GFP150 (ADRGFP150) board is
interrupted while this command is executed.
It will be restored after the switching of the Motherboard Application code.
With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board isnt
interrupted while this command is executed.
- Click the End Session button when the operation is ended.
- Choose the Switch mode to switch the Motherboard Application code.
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Select the soft type: Mother board.

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

8 / 22

266711804.doc
Issue 2 - 29/08/2011

- Click the Show list button to create the equipment list with the software inventory
then on the Switch button to switch the Current and Reserve software.
The result displays in the Status column.
With IONOS NMS P4.3 or lower, after the restart of the equipment, the traffic of the
GFP150 (ADRGFP150) board accesses is restored.
The traffic of other accesses isnt interrupted while this command is executed.
With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board is
interrupted while this command is executed. (60 seconds max.).
The traffic of other accesses isnt interrupted while this command is executed.
- Click the End Session button when the operation is ended.
- Choose the Update mode to download the FPGA (With IONOS NMS P4.4 or higher)
and Motherboard Application code (Second download).
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Reserve Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Reserve Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Click the Close button to close the Software Management window.
- If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment
concerned.
- If the equipment is out of alignment, make an Audit and align the parameters of tabs
with a red cross.
- With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be
beforehand downloaded by HTTP in the equipment (Second download).
- If 4E/FE board(s) is(are) configured in the equipment, to use the Jumbo Frame function,
it is necessary to do No Service then Service every board.
(With HTTP, select the 4E/FE board then the menu : Service )
The traffic of 4E/FE board(s) is interrupted while this command is executed.
(60 seconds max.).

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

9 / 22

266711804.doc
Issue 2 - 29/08/2011

3.2 Release P5.4.1 to P5.7.0


3.2.1 ADR155c software installation
ADR155c upgrade:
Software (*)
Old Code
Motherboard Boot
252 165 976AC-ec
Motherboard Application
252 860 654AA-ni
FPGA Pack
252 860 667AA-vm
GFP150 board Application
251 863 036AJ-nc
(ADRGFP150)
(*): Modified software appears in Bold type

New Code (*)


252 165 976AC-ec
3 000 297 311-sa
253 349 071AA-we
251 863 036AK-of

No STM1DUAL5G,STM1SFP5G,4E/FE+1GEandGFP150(253243224Borupper)
board must be inserted into the shelf before starting the upgrade procedure.

Upgrade procedure with HTTP and a TFTP server for FPGA Pack as well as GFP150
(ADRGFP150) and Motherboard software Application:
- Copy the files Fpga56we.gz, Gfp150of.gz and Adr570sa.gz into the reference (root)
directory of the TFTP server. ( IONOS NMS installation directory \tftproot)
- For each ADR155c in the network:
Start HTTP on the ADR155c to be upgraded.
Select the Equipment\Up and Download\Download menus then enter the TFTP server
address under TFTP Server .
Fill the File description and select the Type of Downloaded Informations .
- Download FPGA Pack
: File Fpga56we.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 45 seconds per intermediate
equipment).
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations .
- Download Motherboard Application code
: File Adr570sa.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 2 minutes per intermediate
equipment).
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations .
- Download GFP150 (ADRGFP150) Application code : File Gfp150of.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 1 minute per intermediate
equipment).
Use the Switching menu to check the version of the downloaded codes.
(Select the menu then Switching )

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

10 / 22

266711804.doc
Issue 2 - 29/08/2011

Switch (Switch command) the GFP150 (ADRGFP150) Code.


Validate the warning message.
The traffic of GFP150 (ADRGFP150) board isnt interrupted while this command is
executed.
Select the Reload menu then check the switch of GFP150 (ADRGFP150) Code.
Switch (Switch and Reset command) the Motherboard Code.
This causes a hot reset.
Validate the warning message.
The traffic of GFP150 (ADRGFP150) board is interrupted while this command is
executed. (60 seconds max.).
The traffic of other accesses isnt interrupted while this command is executed.
Re-log on to the equipment with HTTP.
Use the Download menu to check that the Motherboard code has been switched.
(Menus : Up and Download\Download )
In the Download menu, fill the File description and select
the Type of Downloaded Informations (Second download) :
- Download FPGA Pack
: File Fpga56we.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 45 seconds per intermediate
equipment).
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations (Second download) :
- Download Motherboard Application code
: File Adr570sa.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 2 minutes per intermediate
equipment).
Select the Reload menu then check the downloaded code.
The Motherboard codes (current) and (reserve) are the same reference.
If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment
concerned.
If 4E/FE board(s) is(are) configured in the equipment, to use the Jumbo Frame function,
it is necessary to do No Service then Service every board.
(Select the 4E/FE board then the menu : Service )
The traffic of 4E/FE board(s) is interrupted while this command is executed.
(60 seconds max.).
Upgrade procedure with IONOS NMS and a TFTP server for FPGA Pack as well as
GFP150 (ADRGFP150) and Motherboard software Application:
Note: With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be
beforehand downloaded by HTTP in the equipment.
With IONOS NMS P4.4 or higher, the FPGA Pack (File: Fpga56we.gz) can be
downloaded by IONOS NMS.
Document SAGEMCOM - Reproduction et divulgation interdites
SAGEMCOM document - Reproduction and disclosure prohibited

11 / 22

266711804.doc
Issue 2 - 29/08/2011

- Copy the files Fpga56we.gz (with IONOS NMS P4.4 or higher), Gfp150of.gz and
Adr570sa.gz into the directory on the hard disk of the PC. (For example: C:\ADR155c).
- Display the Software Management window.
(In the menu bar of the Manager, select the menus: Tools \ Software Management ).
- Choose the Update mode to download the new software.
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Select select the soft type: ADRGFP board and the switch type: Switch and Reset.
- Select the file Gfp150of.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
- Click the Switch button to switch the Current and Reserve software.
The result displays in the Status column.
With IONOS NMS P4.3 or lower, the traffic of GFP150 (ADRGFP150) board is
interrupted while this command is executed.
It will be restored after the switching of the Motherboard Application code.
With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board isnt
interrupted while this command is executed.
- Click the End Session button when the operation is ended.
- Choose the Switch mode to switch the Motherboard Application code.
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Select the soft type: Mother board.

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

12 / 22

266711804.doc
Issue 2 - 29/08/2011

- Click the Show list button to create the equipment list with the software inventory
then on the Switch button to switch the Current and Reserve software.
The result displays in the Status column.
With IONOS NMS P4.3 or lower, after the restart of the equipment, the traffic of the
GFP150 (ADRGFP150) board accesses is restored.
The traffic of other accesses isnt interrupted while this command is executed.
With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board is
interrupted while this command is executed. (60 seconds max.).
The traffic of other accesses isnt interrupted while this command is executed.
- Click the End Session button when the operation is ended.
- Choose the Update mode to download the FPGA (With IONOS NMS P4.4 or higher)
and Motherboard Application code (Second download).
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Reserve Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Select the soft type : Mother board.
- Select the file Adr570sa.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Reserve Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Click the Close button to close the Software Management window.
- If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment
concerned.
- If the equipment is out of alignment, make an Audit and align the parameters of tabs
with a red cross.
- With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be
beforehand downloaded by HTTP in the equipment (Second download).
- If 4E/FE board(s) is(are) configured in the equipment, to use the Jumbo Frame function,
it is necessary to do No Service then Service every board.
(With HTTP, select the 4E/FE board then the menu : Service )
The traffic of 4E/FE board(s) is interrupted while this command is executed.
(60 seconds max.).

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

13 / 22

266711804.doc
Issue 2 - 29/08/2011

3.3 Release P5.4.5 to P5.7.0


3.3.1 ADR155c software installation
ADR155c upgrade:
Software (*)
Old Code
Motherboard Boot
252 165 976AC-ec
Motherboard Application
3 000 297 311-og
FPGA Pack
252 860 667AA-vm
GFP150 board Application
251 863 036AK-oe
(ADRGFP150)
(*): Modified software appears in Bold type

New Code (*)


252 165 976AC-ec
3 000 297 311-sa
253 349 071AA-we
251 863 036AK-of

NoSTM1DUAL5G,STM1SFP5G,4E/FE+1GEandGFP150(253243224Borupper)
board must be inserted into the shelf before starting the upgrade procedure.

Upgrade procedure with HTTP and a TFTP server for FPGA Pack as well as GFP150
(ADRGFP150) and Motherboard software Application:
- Copy the files Fpga56we.gz, Gfp150of.gz and Adr570sa.gz into the reference (root)
directory of the TFTP server. ( IONOS NMS installation directory \tftproot)
- For each ADR155c in the network:
Start HTTP on the ADR155c to be upgraded.
Select the Equipment\Up and Download\Download menus then enter the TFTP server
address under TFTP Server .
Fill the File description and select the Type of Downloaded Informations .
- Download FPGA Pack
: File Fpga56we.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 45 seconds per intermediate
equipment).
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations .
- Download Motherboard Application code
: File Adr570sa.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 2 minutes per intermediate
equipment).
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations .
- Download GFP150 (ADRGFP150) Application code : File Gfp150of.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 1 minute per intermediate
equipment).
Use the Switching menu to check the version of the downloaded codes.
(Select the menu then Switching )

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

14 / 22

266711804.doc
Issue 2 - 29/08/2011

Switch (Switch command) the GFP150 (ADRGFP150) Code.


Validate the warning message.
The traffic of GFP150 (ADRGFP150) board isnt interrupted while this command is
executed.
Select the Reload menu then check the switch of GFP150 (ADRGFP150) Code.
Switch (Switch and Reset command) the Motherboard Code.
This causes a hot reset.
Validate the warning message.
The traffic of GFP150 (ADRGFP150) board is interrupted while this command is
executed. (60 seconds max.).
The traffic of other accesses isnt interrupted while this command is executed.
Re-log on to the equipment with HTTP.
Use the Download menu to check that the Motherboard code has been switched.
(Menus: Up and Download\Download )
In the Download menu, fill the File description and select
the Type of Downloaded Informations (Second download) :
- Download FPGA Pack
: File Fpga56we.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 45 seconds per intermediate
equipment).
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations (Second download) :
- Download Motherboard Application code
: File Adr570sa.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 2 minutes per intermediate
equipment).
Select the Reload menu then check the downloaded code.
The Motherboard codes (current) and (reserve) are the same reference.
If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment
concerned.
If 4E/FE board(s) is(are) configured in the equipment, to use the Jumbo Frame function,
it is necessary to do No Service then Service every board.
(Select the 4E/FE board then the menu : Service )
The traffic of 4E/FE board(s) is interrupted while this command is executed.
(60 seconds max.).
Upgrade procedure with IONOS NMS and a TFTP server for FPGA Pack as well as
GFP150 (ADRGFP150) and Motherboard software Application:
Note: With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be
beforehand downloaded by HTTP in the equipment.
With IONOS NMS P4.4 or higher, the FPGA Pack (File: Fpga56we.gz) can be
downloaded by IONOS NMS.
Document SAGEMCOM - Reproduction et divulgation interdites
SAGEMCOM document - Reproduction and disclosure prohibited

15 / 22

266711804.doc
Issue 2 - 29/08/2011

- Copy the files Fpga56we.gz (with IONOS NMS P4.4 or higher), Gfp150of.gz and
Adr570sa.gz into the directory on the hard disk of the PC. (For example: C:\ADR155c).
- Display the Software Management window.
(In the menu bar of the Manager, select the menus: Tools \ Software Management ).
- Choose the Update mode to download the new software.
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Select select the soft type: ADRGFP board and the switch type: Switch and Reset.
- Select the file Gfp150of.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
- Click the Switch button to switch the Current and Reserve software.
The result displays in the Status column.
With IONOS NMS P4.3 or lower, the traffic of GFP150 (ADRGFP150) board is
interrupted while this command is executed.
It will be restored after the switching of the Motherboard Application code.
With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board isnt
interrupted while this command is executed.
- Click the End Session button when the operation is ended.
- Choose the Switch mode to switch the Motherboard Application code.
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Select the soft type: Mother board.
- Click the Show list button to create the equipment list with the software inventory
then on the Switch button to switch the Current and Reserve software.
The result displays in the Status column.
With IONOS NMS P4.3 or lower, after the restart of the equipment, the traffic of the
GFP150 (ADRGFP150) board accesses is restored.
Document SAGEMCOM - Reproduction et divulgation interdites
SAGEMCOM document - Reproduction and disclosure prohibited

16 / 22

266711804.doc
Issue 2 - 29/08/2011

The traffic of other accesses isnt interrupted while this command is executed.
With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board is
interrupted while this command is executed. (60 seconds max.).
The traffic of other accesses isnt interrupted while this command is executed.
- Click the End Session button when the operation is ended.
- Choose the Update mode to download the FPGA (With IONOS NMS P4.4 or higher)
and Motherboard Application code (Second download).
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Reserve Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Reserve Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Click the Close button to close the Software Management window.
- If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment
concerned.
- If the equipment is out of alignment, make an Audit and align the parameters of tabs
with a red cross.
- With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be
beforehand downloaded by HTTP in the equipment (Second download).
- If 4E/FE board(s) is(are) configured in the equipment, to use the Jumbo Frame function,
it is necessary to do No Service then Service every board.
(With HTTP, select the 4E/FE board then the menu : Service )
The traffic of 4E/FE board(s) is interrupted while this command is executed.
(60 seconds max.).

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

17 / 22

266711804.doc
Issue 2 - 29/08/2011

3.4 Release P5.4.6 to P5.7.0


3.4.1 ADR155c software installation
ADR155c upgrade:
Software (*)
Old Code
Motherboard Boot
252 165 976AC-ec
Motherboard Application
3 000 297 311-ol
FPGA Pack
252 860 667AA-vm
GFP150 board Application
251 863 036AK-oe
(ADRGFP150)
(*): Modified software appears in Bold type

New Code (*)


252 165 976AC-ec
3 000 297 311-sa
253 349 071AA-we
251 863 036AK-of

NoSTM1DUAL5G,STM1SFP5G,4E/FE+1GEandGFP150(253243224Borupper)
board must be inserted into the shelf before starting the upgrade procedure.

Upgrade procedure with HTTP and a TFTP server for FPGA Pack as well as GFP150
(ADRGFP150) and Motherboard software Application:
- Copy the files Fpga56we.gz, Gfp150of.gz and Adr570sa.gz into the reference (root)
directory of the TFTP server. ( IONOS NMS installation directory \tftproot)
- For each ADR155c in the network:
Start HTTP on the ADR155c to be upgraded.
Select the Equipment\Up and Download\Download menus then enter the TFTP server
address under TFTP Server .
Fill the File description and select the Type of Downloaded Informations .
- Download FPGA Pack
: File Fpga56we.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 45 seconds per intermediate
equipment).
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations .
- Download Motherboard Application code
: File Adr570sa.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 2 minutes per intermediate
equipment).
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations .
- Download GFP150 (ADRGFP150) Application code : File Gfp150of.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 1 minute per intermediate
equipment).
Use the Switching menu to check the version of the downloaded codes.
(Select the menu then Switching )

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

18 / 22

266711804.doc
Issue 2 - 29/08/2011

Switch (Switch command) the GFP150 (ADRGFP150) Code.


Validate the warning message.
The traffic of GFP150 (ADRGFP150) board isnt interrupted while this command is
executed.
Select the Reload menu then check the switch of GFP150 (ADRGFP150) Code.
Switch (Switch and Reset command) the Motherboard Code.
This causes a hot reset.
Validate the warning message.
The traffic of GFP150 (ADRGFP150) board is interrupted while this command is
executed. (60 seconds max.).
The traffic of other accesses isnt interrupted while this command is executed.
Re-log on to the equipment with HTTP.
Use the Download menu to check that the Motherboard code has been switched.
(Menus : Up and Download\Download )
In the Download menu, fill the File description and select
the Type of Downloaded Informations (Second download) :
- Download FPGA Pack
: File Fpga56we.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 45 seconds per intermediate
equipment).
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations (Second download) :
- Download Motherboard Application code
: File Adr570sa.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 2 minutes per intermediate
equipment).
Select the Reload menu then check the downloaded code.
The Motherboard codes (current) and (reserve) are the same reference.
If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment
concerned.
Upgrade procedure with IONOS NMS and a TFTP server for FPGA Pack as well as
GFP150 (ADRGFP150) and Motherboard software Application:
Note: With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be
beforehand downloaded by HTTP in the equipment.
With IONOS NMS P4.4 or higher, the FPGA Pack (File: Fpga56we.gz) can be
downloaded by IONOS NMS.

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

19 / 22

266711804.doc
Issue 2 - 29/08/2011

- Copy the files Fpga56we.gz (with IONOS NMS P4.4 or higher), Gfp150of.gz and
Adr570sa.gz into the directory on the hard disk of the PC. (For example : C:\ADR155c).
- Display the Software Management window.
(In the menu bar of the Manager, select the menus : Tools \ Software Management ).
- Choose the Update mode to download the new software.
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type : FPGA.
- Select the file Fpga56we.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Select the soft type : Mother board.
- Select the file Adr570sa.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Select select the soft type: ADRGFP board and the switch type: Switch and Reset.
- Select the file Gfp150of.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
- Click the Switch button to switch the Current and Reserve software.
The result displays in the Status column.
With IONOS NMS P4.3 or lower, the traffic of GFP150 (ADRGFP150) board is
interrupted while this command is executed.
It will be restored after the switching of the Motherboard Application code.
With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board isnt
interrupted while this command is executed.
- Click the End Session button when the operation is ended.
- Choose the Switch mode to switch the Motherboard Application code.
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Select the soft type: Mother board.
- Click the Show list button to create the equipment list with the software inventory
then on the Switch button to switch the Current and Reserve software.
The result displays in the Status column.
With IONOS NMS P4.3 or lower, after the restart of the equipment, the traffic of the
GFP150 (ADRGFP150) board accesses is restored.
Document SAGEMCOM - Reproduction et divulgation interdites
SAGEMCOM document - Reproduction and disclosure prohibited

20 / 22

266711804.doc
Issue 2 - 29/08/2011

The traffic of other accesses isnt interrupted while this command is executed.
With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board is
interrupted while this command is executed. (60 seconds max.).
The traffic of other accesses isnt interrupted while this command is executed.
- Click the End Session button when the operation is ended.
- Choose the Update mode to download the FPGA (With IONOS NMS P4.4 or higher)
and Motherboard Application code (Second download).
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Reserve Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Select the soft type : Mother board.
- Select the file Adr570sa.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Reserve Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Click the Close button to close the Software Management window.
- If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment
concerned.
- If the equipment is out of alignment, make an Audit and align the parameters of tabs
with a red cross.
- With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be
beforehand downloaded by HTTP in the equipment (Second download).

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

21 / 22

266711804.doc
Issue 2 - 29/08/2011

3.5 Release P5.5.0 to P5.7.0


3.5.1 ADR155c software installation
ADR155c upgrade:
Software (*)
Old Code
Motherboard Boot
252 165 976AC-ec
Motherboard Application
3 000 297 311-pd
FPGA Pack
252 209 235AA-wc
GFP150 board Application
251 863 036AK-oe
(ADRGFP150)
(*): Modified software appears in Bold type

New Code (*)


252 165 976AC-ec
3 000 297 311-sa
253 349 071AA-we
251 863 036AK-of

NoGFP150(253243224Borupper)board must be inserted into the shelf before starting the


upgrade procedure.

Upgrade procedure with HTTP and a TFTP server for FPGA Pack as well as GFP150
(ADRGFP150) and Motherboard software Application:
- Copy the files Fpga56we.gz, Gfp150of.gz and Adr570sa.gz into the reference (root)
directory of the TFTP server. ( IONOS NMS installation directory \tftproot)
- For each ADR155c in the network:
Start HTTP on the ADR155c to be upgraded.
Select the Equipment\Up and Download\Download menus then enter the TFTP server
address under TFTP Server .
Fill the File description and select the Type of Downloaded Informations .
- Download FPGA Pack
: File Fpga56we.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 45 seconds per intermediate
equipment).
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations .
- Download Motherboard Application code
: File Adr570sa.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 2 minutes per intermediate
equipment).
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations .
- Download GFP150 (ADRGFP150) Application code : File Gfp150of.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 1 minute per intermediate
equipment).
Use the Switching menu to check the version of the downloaded codes.
(Select the menu then Switching )
Switch (Switch command) the GFP150 (ADRGFP150) Code.
Document SAGEMCOM - Reproduction et divulgation interdites
SAGEMCOM document - Reproduction and disclosure prohibited

22 / 22

266711804.doc
Issue 2 - 29/08/2011

Validate the warning message.


The traffic of GFP150 (ADRGFP150) board isnt interrupted while this command is
executed.
Select the Reload menu then check the switch of GFP150 (ADRGFP150) Code.
Switch (Switch and Reset command) the Motherboard Code.
This causes a hot reset.
Validate the warning message.
The traffic of GFP150 (ADRGFP150) board is interrupted while this command is
executed. (60 seconds max.).
The traffic of other accesses isnt interrupted while this command is executed.
Re-log on to the equipment with HTTP.
Use the Download menu to check that the Motherboard code has been switched.
(Menus: Up and Download\Download )
In the Download menu, fill the File description and select
the Type of Downloaded Informations (Second download) :
- Download FPGA Pack
: File Fpga56we.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 45 seconds per intermediate
equipment).
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations (Second download) :
- Download Motherboard Application code
: File Adr570sa.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 2 minutes per intermediate
equipment).
Select the Reload menu then check the downloaded code.
The Motherboard codes (current) and (reserve) are the same reference.
If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment
concerned.
If 4E/FE-1GE board(s) is(are) configured in the equipment, it is necessary to do No
Service then Service every board.
(Select the 4E/FE-1GE board then the menu : Service )
The traffic of 4E/FE-1GE board(s) is interrupted while this command is executed.
(60 seconds max.).
Upgrade procedure with IONOS NMS and a TFTP server for FPGA Pack as well as
GFP150 (ADRGFP150) and Motherboard software Application:
Note: With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be
beforehand downloaded by HTTP in the equipment.
With IONOS NMS P4.4 or higher, the FPGA Pack (File: Fpga56we.gz) can be
downloaded by IONOS NMS.

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

23 / 22

266711804.doc
Issue 2 - 29/08/2011

- Copy the files Fpga56we.gz (with IONOS NMS P4.4 or higher), Gfp150of.gz and
Adr570sa.gz into the directory on the hard disk of the PC. (For example: C:\ADR155c).
- Display the Software Management window.
(In the menu bar of the Manager, select the menus: Tools \ Software Management ).
- Choose the Update mode to download the new software.
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Select select the soft type : ADRGFP board and the switch type : Switch and Reset.
- Select the file Gfp150of.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
- Click the Switch button to switch the Current and Reserve software.
The result displays in the Status column.
With IONOS NMS P4.3 or lower, the traffic of GFP150 (ADRGFP150) board is
interrupted while this command is executed.
It will be restored after the switching of the Motherboard Application code.
With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board isnt
interrupted while this command is executed.
- Click the End Session button when the operation is ended.
- Choose the Switch mode to switch the Motherboard Application code.
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Select the soft type: Mother board.

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

24 / 22

266711804.doc
Issue 2 - 29/08/2011

- Click the Show list button to create the equipment list with the software inventory
then on the Switch button to switch the Current and Reserve software.
The result displays in the Status column.
With IONOS NMS P4.3 or lower, after the restart of the equipment, the traffic of the
GFP150 (ADRGFP150) board accesses is restored.
The traffic of other accesses isnt interrupted while this command is executed.
With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board is
interrupted while this command is executed. (60 seconds max.).
The traffic of other accesses isnt interrupted while this command is executed.
- Click the End Session button when the operation is ended.
- Choose the Update mode to download the FPGA (With IONOS NMS P4.4 or higher)
and Motherboard Application code (Second download).
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Only with IONOS NMS P4.4 or higher, select the soft type: FPGA.
- Select the file Fpga56we.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Reserve Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Reserve Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Click the Close button to close the Software Management window.
- If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment
concerned.
- If the equipment is out of alignment, make an Audit and align the parameters of tabs
with a red cross.
- With IONOS NMS P4.3 or lower, the FPGA Pack (File: Fpga56we.gz) must be
beforehand downloaded by HTTP in the equipment (Second download).
- If 4E/FE-1GE board(s) is(are) configured in the equipment, it is necessary to do No
Service then Service every board.
(Select the 4E/FE-1GE board then the menu : Service )
The traffic of 4E/FE-1GE board(s) is interrupted while this command is executed.
(60 seconds max.).

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

25 / 22

266711804.doc
Issue 2 - 29/08/2011

3.6 Release P5.6.0 to P5.7.0


3.6.1 ADR155c software installation
ADR155c upgrade:
Software (*)
Old Code
Motherboard Boot
252 165 976AC-ec
Motherboard Application
3 000 297 311-qe
FPGA Pack
252 209 235AA-we
GFP150 board Application
251 863 036AK-oe
(ADRGFP150)
(*): Modified software appears in Bold type

New Code (*)


252 165 976AC-ec
3 000 297 311-sa
253 349 071AA-we
251 863 036AK-of

NoGFP150(253243224Corupper)board must be inserted into the shelf before starting the


upgrade procedure.

Upgrade procedure with HTTP and a TFTP server for GFP150 (ADRGFP150) and
Motherboard software Application:
- Copy the files Gfp150of.gz and Adr570sa.gz into the reference (root) directory of the
TFTP server. ( IONOS NMS installation directory \tftproot)
- For each ADR155c in the network:
Start HTTP on the ADR155c to be upgraded.
Select the Equipment\Up and Download\Download menus then enter the TFTP server
address under TFTP Server .
Fill the File description and select the Type of Downloaded Informations .
- Download Motherboard Application code
: File Adr570sa.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 2 minutes per intermediate
equipment).
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations .
- Download GFP150 (ADRGFP150) Application code : File Gfp150of.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 1 minute per intermediate
equipment).
Use the Switching menu to check the version of the downloaded codes.
(Select the menu then Switching )
Switch (Switch command) the GFP150 (ADRGFP150) Code.
Validate the warning message.
The traffic of GFP150 (ADRGFP150) board isnt interrupted while this command is
executed.
Select the Reload menu then check the switch of GFP150 (ADRGFP150) Code.
Switch (Switch and Reset command) the Motherboard Code.
This causes a hot reset.
Validate the warning message.
Document SAGEMCOM - Reproduction et divulgation interdites
SAGEMCOM document - Reproduction and disclosure prohibited

26 / 22

266711804.doc
Issue 2 - 29/08/2011

The traffic of GFP150 (ADRGFP150) board is interrupted while this command is


executed. (60 seconds max.).
The traffic of other accesses isnt interrupted while this command is executed.
Re-log on to the equipment with HTTP.
Use the Download menu to check that the Motherboard code has been switched.
(Menus : Up and Download\Download )
In the Download menu, fill the File description and select
the Type of Downloaded Informations (Second download) :
- Download Motherboard Application code
: File Adr570sa.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 2 minutes per intermediate
equipment).
Select the Reload menu then check the downloaded code.
The Motherboard codes (current) and (reserve) are the same reference.
If GFP150 board(s) is(are) configured in the equipment, it is necessary to do No

Service then Service every board. (Select the GFP150 board then the menu :
Service )
The traffic of GFP150 board(s) is interrupted while this command is executed.
(60 seconds max.).
If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment
concerned.
Upgrade procedure with IONOS NMS and a TFTP server for GFP150 (ADRGFP150) and
Motherboard software Application:
- Copy the files Gfp150of.gz and Adr570sa.gz into the directory on the hard disk of the PC.
(For example: C:\ADR155c).
- Display the Software Management window.
(In the menu bar of the Manager, select the menus: Tools \ Software Management ).
- Choose the Update mode to download the new software.
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Select select the soft type: ADRGFP board and the switch type : Switch and Reset.
- Select the file Gfp150of.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
Document SAGEMCOM - Reproduction et divulgation interdites
SAGEMCOM document - Reproduction and disclosure prohibited

27 / 22

266711804.doc
Issue 2 - 29/08/2011

- Click the Switch button to switch the Current and Reserve software.
The result displays in the Status column.
With IONOS NMS P4.3 or lower, the traffic of GFP150 (ADRGFP150) board is
interrupted while this command is executed.
It will be restored after the switching of the Motherboard Application code.
With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board isnt
interrupted while this command is executed.
- Click the End Session button when the operation is ended.
- Choose the Switch mode to switch the Motherboard Application code.
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Select the soft type: Mother board.
- Click the Show list button to create the equipment list with the software inventory
then on the Switch button to switch the Current and Reserve software.
The result displays in the Status column.
With IONOS NMS P4.3 or lower, after the restart of the equipment, the traffic of the
GFP150 (ADRGFP150) board accesses is restored.
The traffic of other accesses isnt interrupted while this command is executed.
With IONOS NMS P4.4 or higher, the traffic of GFP150 (ADRGFP150) board is
interrupted while this command is executed. (60 seconds max.).
The traffic of other accesses isnt interrupted while this command is executed.
- Click the End Session button when the operation is ended.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Reserve Download button to launch the downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Click the Close button to close the Software Management window.
- If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment
concerned.
- If GFP150 board(s) is(are) configured in the equipment, it is necessary to do No
Service then Service every board. (Select the GFP150 board then the menu :
Service )
The traffic of GFP150 board(s) is interrupted while this command is executed.
(60 seconds max.).
- If the equipment is out of alignment, make an Audit and align the parameters of tabs
with a red cross.

3.7 Release P5.6.1 to P5.7.0


3.7.1 ADR155c software installation
ADR155c upgrade:
Document SAGEMCOM - Reproduction et divulgation interdites
SAGEMCOM document - Reproduction and disclosure prohibited

28 / 22

266711804.doc
Issue 2 - 29/08/2011

Software (*)
Old Code
Motherboard Boot
252 165 976AC-ec
Motherboard Application
3 000 297 311-rd
FPGA Pack
253 349 071AA-we
GFP150 board Application
251 863 036AK-of
(ADRGFP150)
(*): Modified software appears in Bold type

New Code (*)


252 165 976AC-ec
3 000 297 311-sa
253 349 071AA-we
251 863 036AK-of

Upgrade procedure with HTTP and a TFTP server for Motherboard software Application:
- Copy the files Adr570sa.gz into the reference (root) directory of the TFTP server.
( IONOS NMS installation directory \tftproot)
- For each ADR155c in the network:
Start HTTP on the ADR155c to be upgraded.
Select the Equipment\Up and Download\Download menus then enter the TFTP server
address under TFTP Server .
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations .
- Download Motherboard Application code
: File Adr570sa.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 2 minutes per intermediate
equipment).
Use the Switching menu to check the version of the downloaded codes.
(Select the menu then Switching )
Switch (Switch and Reset command) the Motherboard Code.
This causes a hot reset.
Validate the warning message.
The traffic isnt interrupted while this command is executed.
Re-log on to the equipment with HTTP.
Use the Download menu to check that the Motherboard code has been switched.
(Menus: Up and Download\Download )
Select the Reload menu then fill the File description and select
the Type of Downloaded Informations (Second download) :
- Download Motherboard Application code
: File Adr570sa.gz
Click APPLY and wait for the information POST COMPLETED.
All data successfully submitted to the device. (Until 2 minutes per intermediate
equipment).
Select the Reload menu then check the downloaded code.
The Motherboard codes (current) and (reserve) are the same reference.
If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment
concerned.
If the equipment is out of alignment, make an Audit and align the parameters of tabs
with a red cross.
Document SAGEMCOM - Reproduction et divulgation interdites
SAGEMCOM document - Reproduction and disclosure prohibited

29 / 22

266711804.doc
Issue 2 - 29/08/2011

Upgrade procedure with IONOS NMS and a TFTP server for Motherboard software
Application:
- Copy the file Adr570sa.gz into the directory on the hard disk of the PC. (For example:
C:\ADR155c).
- Display the Software Management window.
(In the menu bar of the Manager, select the menus: Tools \ Software Management ).
- Choose the Update mode to download the new software.
- Select the equipment to be upgraded with the Browse button.
- Tick ADR155c.
- Select the soft type: Mother board.
- Select the file Adr570sa.gz to be downloaded with the Browse button.
- Click the Show list button to create the equipment list with the software inventory
then on the Download button to launch the downloading.
The result displays in the Status column.
- Click the Switch button to switch the Current and Reserve software.
The result displays in the Status column.
The traffic isnt interrupted while this command is executed.
- Click the Reserve Download button to launch the second downloading.
The result displays in the Status column.
- Click the End Session button when the operation is ended.
- Click the Close button to close the Software Management window.
- If the MSP 1+1 protection were used before the upgrade, reconfigure the equipment
concerned.
- If the equipment is out of alignment, make an Audit and align the parameters of tabs
with a red cross.

Document SAGEMCOM - Reproduction et divulgation interdites


SAGEMCOM document - Reproduction and disclosure prohibited

30 / 22

266711804.doc
Issue 2 - 29/08/2011