You are on page 1of 14

Tetra Plex

Plate heat exchanger


Pre-calculation manual

Use this Pre-calculation manual for


faster handling of your PHE budget
quotations
Note, that the prices are Transfer
Prices in EURO
This is an internal document only

Content

Page

Milk cooling ..........................................................2


Milk pasteurisation, 90% heat recovery ...............3
Milk pasteurisation, 92% heat recovery ...............4
Milk pasteurisation, 94% heat recovery ...............5
Cheese milk pasteurisation ..................................6
Yoghurt milk pasteurisation ..................................7
Cream pasteurisation, warm cream,
80% heat recovery ........................................ 8
Cream pasteurisation,cold cream,
80% heat recovery ........................................ 9
Fruit concentrate cooling ...................................10
Fruit juice pasteurisation, 85% heat recovery ....11
Fruit juice pasteurisation, with deaeration .........12
Fruit juice pasteurisation, hot filling ...................13
CIP heating .........................................................14

Milk Cooling

Tetra Plex Plate Heat Exchangers

General
The heat exchangers are calculated to handle some variations in inlet temperature.
Each plate heat exchanger can handle a range of capacities, see below table.
IW
2

15

Product
Raw milk
Pressure drop for product 150 kPa.
Temperature program
15 (10) - 4C
Acceptable variations in temperatures.
Inlet temperature: 15 - 10C
Cooling media
Ice water of 2C. Pressure drop for cooling media in heat exchanger is max. 150 kPa.
Cooling load is given for the case of a product inlet temperature of 15C

Item
9612628955
9612628956
9612628957
9612628958
9612628959
9612628960
9612628961
9612628962
9612628963
9612628964
9612628965
9612628966

File name
02
05
08
10
15
20
25
30
35
40
45
50

MS3-SBL 1s1a
MS6-SBL 1s1a
MS6-SBL 1s1a
MS6-SBL 1s1a
MS6-SBL 1s1a
MS10-SBL 1s1a
MS10-SBL 1s1a
MS10-SBL 1s1a
MS10-SBL 1s1a
MS10-SM 1s1a
MS10-SM 1s1a
MS10-SM 1s1a

Alsis
code

Product
HE type

3541
3542
3542
3542
3542
3543
3543
3543
3543
3553
3553
3553

MS3-SBL
MS6-SBL
MS6-SBL
MS6-SBL
MS6-SBL
MS10-SBL
MS10-SBL
MS10-SBL
MS10-SBL
MS10-SM
MS10-SM
MS10-SM

Click here for technical specifications for each item

Capacity l/h
1000 to 2000
2000 to 5000
6000 to 8000
9000 to 10000
11000 to 15000
16000 to 20000
21000 to 25000
26000 to 30000
31000 to 35000
36000 to 40000
41000 to 45000
46000 to 50000

Note!
Heating
flow l/h

Cooling
flow l/h
4000
10000
16000
20000
30000
40000
50000
60000
70000
80000
90000
100000

Transfer
price EUR
1200
1810
2010
2160
2580
4280
4680
5230
5720
7690
8180
8870

Milk Pasteurization, 90 % Heat Recovery

Tetra Plex Plate Heat Exchangers

General
The heat exchangers are calculated to handle some variations in inlet and outlet temperatures as well as as to compensate for the temperature loss in
a deaerator. Outlets for separator, homogeniser and deaerator are included. Each plate heat exchanger can handle a range of capacities, see below
table.
74

HW

2
IW

74

Sep.

Hom.

Product
Milk or skimmilk. Total solids up to 15%. Total pressure drop for product 250-350 kPa.
Temperature program
4 - 55 - 67 - 74 - 4 C
Acceptable variations in temperatures
Inlet temperature: 3-8C
Pasteurization temperature: 72-80C
Outlet temperature to separator, homogeniser and deaerator will vary slightly depending on pasteurization temperature and the amount of separated
cream that is diverted.
Heating media
Hot water from external source with a temperature of maximum 3C above pasteurization temperature. Heat load is given for conti nous running without
deaerator. Heat load is doubled during start up.
Cooling media
Ice water of 2C. Pressure drop for cooling media in heat exchanger is max. 150 kPa.
Cooling load is given for the case of a product inlet temperature of 4C

Item
9612628967
9612628968
9612628969
9612628970
9612628971
9612628972
9612628973
9612628974
9612628975
9612628976
9612628977
9612628978
9612628979

02
03
04
05
06
07
10
13
15
20
25
30
35

File name

Alsis
code

C3-SR 4s1a
MS6-SR 4s1a
MS6-SR 4s1a
MS6-SR 4s1a
MS6-SR 4s1a
C6-SR 4s1a
C6-SR 4s1a
C8-SR 4s1a
C8-SR 4s1a
C8-SR 4s1a
C8-SR 4s1a
C10-SR 4s1a
C10-SR 4s1a

3544
3552
3552
3552
3552
3545
3545
3546
3546
3546
3546
3547
3547

Product
HE type
C3-SR
MS6-SR
MS6-SR
MS6-SR
MS6-SR
C6-SR
C6-SR
C8-SR
C8-SR
C8-SR
C8-SR
C10-SR
C10-SR

Capacity l/h
1000 to 2000
2000 to 3000
3000 to 4000
4000 to 5000
5000 to 6000
6000 to 7000
8000 to 10000
11000 to 13000
14000 to 15000
16000 to 20000
21000 to 25000
26000 to 30000
31000 to 35000

Note!
Heating
flow l/h

Cooling
flow l/h

2500
3600
4800
6000
7200
9000
12000
15000
18000
24000
30000
35000
40000

4000
6000
8000
10000
12000
14000
20000
26000
30000
40000
50000
60000
70000

Transfer
price EUR
4320
6460
6740
7150
7570
11090
12550
15630
16860
19020
20830
26440
28160

Click here for technical specifications for each item

Milk Pasteurization, 92% Heat Recovery

Tetra Plex Plate Heat Exchangers

General
The heat exchangers are calculated to handle some variations in inlet and outlet temperatures as well as as to compensate for the temperature loss in
a deaerator. Outlets for separator, homogeniser and deaerator are included. Each plate heat exchanger can handle a range of capacities, see below
table.
74

HW

2
IW

74

Sep.

Hom.

Product
Milk or skimmilk. Total solids up to 15%. Total pressure drop for product 250-350 kPa.
Temperature program
4 - 55 - 68 - 74 - 4 C
Acceptable variations in temperatures
Inlet temperature: 3-8C
Pasteurization temperature: 72-80C
Outlet temperature to separator, homogeniser and deaerator will vary slightly depending on pasteurization temperature and the amount of separated
cream that is diverted.
Heating media
Hot water from external source with a temperature of maximum 3C above pasteurization temperature. Heat load is given for conti nous running without
deaerator. Heat load is doubled during start up.
Cooling media
Ice water of 2C. Pressure drop for cooling media in heat exchanger is max. 150 kPa.
Cooling load is given for the case of a product inlet temperature of 4C

Item

File name

Alsis
code

Product
HE type

Capacity l/h

Heating
flow l/h

Cooling
flow l/h

Transfer
price EUR

9612628980

02 C3-SR 4s1a

3544

C3-SR

1000 to 2000

2500

3000

4530

9612628981

03 MS6-SR 4s1a

3552

MS6-SR

2000 to 3000

3600

6000

6630

9612628982

04 MS6-SR 4s1a

3552

MS6-SR

3000 to 4000

4800

8000

7210

9612628983

05 MS6-SR 4s1a

3552

MS6-SR

4000 to 5000

6000

10000

7740

9612628984

06 C6-SR 4s1a

3545

C6-SR

5000 to 6000

7200

12000

11310

9612628985

07 C6-SR 4s1a

3545

C6-SR

6000 to 7000

9000

14000

12110

9612628986

10 C8-SR 4s1a

3546

C8-SR

8000 to 10000

12000

20000

15810

9612628987

13 C8-SR 4s1a

3546

C8-SR

11000 to 13000

15000

26000

17290

9612628988

15 C8-SR 4s1a

3546

C8-SR

14000 to 15000

18000

30000

18100

9612628989

20 C8-SR 4s1a

3546

C8-SR

16000 to 20000

24000

40000

20770

9612628990

25 C8-SR 4s1a

3546

C8-SR

21000 to 25000

30000

50000

23270

9612628991

30 C10-SR 4s1a

3547

C10-SR

26000 to 30000

35000

60000

28080

9612628992

35 C10-SR 4s1a

3547

C10-SR

31000 to 35000

40000

70000

30280

Click here for technical specifications for each item

Note!

Tetra Plex Plate Heat Exchangers

Milk Pasteurization, 94% Heat Recovery

General
The heat exchangers are calculated to handle some variations in inlet and outlet temperatures as well as as to compensate for the temperature loss in a
deaerator. Outlets for separator, homogeniser and deaerator are included. Each plate heat exchanger can handle a range of capacities, see below table.

74

HW

2
IW

74

Sep.

Hom.

Product
Milk or skimmilk. Total solids up to 15%. Total pressure drop for product 250-350 kPa.
Temperature program
4 - 55 - 70 - 74 - 4 C
Acceptable variations in temperatures
Inlet temperature: 3-8C
Pasteurization temperature: 72-80C
Outlet temperature to separator, homogeniser and deaerator will vary slightly depending on pasteurization temperature and the amount of separated
cream that is diverted.
Heating media
Hot water from external source with a temperature of maximum 3C above pasteurization temperature. Heat load is given for conti nous running without
deaerator. Heat load is doubled during start up.
Cooling media
Ice water of 2C. Pressure drop for cooling media in heat exchanger is max. 150 kPa.
Cooling load is given for the case of a product inlet temperature of 4C

File name

Alsis
code

9612628993

02 MS6-SR 4s1a

3552

9612628994

03 MS6-SR 4s1a

3552

9612628995

04 MS6-SR 4s1a

9612628996
9612628997
9612628998
9612628999
9612629001

13 C8-SR 4s1a

3546

C8-SR

11000 to 13000

15000

26000

19210

9612629002

15 C8-SR 4s1a

3546

C8-SR

14000 to 15000

18000

30000

20580

9612629003

20 C8-SR 4s1a

3546

C8-SR

16000 to 20000

24000

40000

23700

9612629004

25 C10-SR 4s1a

3547

C10-SR

21000 to 25000

30000

50000

30040

9612629005

30 C10-SR 4s1a

3547

C10-SR

26000 to 30000

35000

60000

32700

9612629006

35 C10-SR 4s1a

3547

C10-SR

31000 to 35000

40000

70000

35400

Item

Product
HE type

Note!

Capacity l/h

Heating
flow l/h

Cooling
flow l/h

Transfer
price EUR

MS6-SR

1000 to 2000

2500

4000

6550

MS6-SR

2000 to 3000

3600

6000

7350

3552

MS6-SR

3000 to 4000

4800

8000

7940

05 MS6-SR 4s1a

3552

MS6-SR

4000 to 5000

6000

10000

8640

06 C6-SR 4s1a

3545

C6-SR

5000 to 6000

7200

12000

13230

07 C8-SR 4s1a

3546

C8-SR

6000 to 7000

9000

14000

15130

10 C8-SR 4s1a

3546

C8-SR

8000 to 10000

12000

20000

17230

Click here for technical specifications for each item

Cheese Milk Pasteurization

Tetra Plex Plate Heat Exchangers

General
The heat exchangers are calculated to handle some variations in inlet and outlet temperatures. The outlet temperature is controlled by bypassing a part
of the flow over the regenerative. A cooling section is included. This is used during starting up and circulation and gives also the possibility to cool milk
to 5C if it for any reason should be stored. Each plate heat exchanger can handle a range of capacities, see below table.
95

30

HW

2
IW

72

Product
Milk. Total solids up to 15%. Total pressure drop for product 250-350 kPa.
Temperature program
4 - 72 - 30 (5) C
Acceptable variations in temperatures
Inlet temperature: 3-8C
Pasteurization temperature: 72-80C
Outlet temperature: 28-33C
Heating media
Hot water from external source with a temperature of maximum 3C above pasteurization temperature. Heat load is given for conti nous running. Heat
load is doubled during start up.
Cooling media
No cooling is needed during normal continous running. Cooling media is only needed when cooling up 5C outlet temperature and a t starting up and
circulation. Ice water of 2C. Pressure drop for cooling media in heat exchanger is max. 150 kPa.

Note!

Item

File name

Alsis
code

Product
HE type

Heating
flow l/h

Cooling
flow l/h

Transfer
price EUR

9612629007

02 C3-SR 3s2a

3544

C3-SR

1000 to 2000

3000

3560

9612629008

05 MS6-SR 3s2a

3552

MS6-SR

2000 to 5000

7000

5730

9612629009

08 MS6-SR 3s2a

3552

MS6-SR

5000 to 8000

10000

6510

9612629010

10 C6-SR 3s2a

3545

C6-SR

9000 to 10000

13000

9830

9612629011

13 C6-SR 3s2a

3545

C6-SR

11000 to 13000

17000

10770

9612629012

15 C6-SR 3s2a

3545

C6-SR

14000 to 15000

20000

11560

9612629013

20 C8-SR 3s2a

3546

C8-SR

16000 to 20000

26000

13710

9612629014

25 C8-SR 3s2a

3546

C8-SR

21000 to 25000

32000

14700

9612629015

30 C8-SR 3s2a

3546

C8-SR

26000 to 30000

38000

15570

9612629016

35 C8-SR 3s2a

3546

C8-SR

31000 to 35000

44000

17110

9612629017

40 C8-SR 3s2a

3546

C8-SR

36000 to 40000

50000

18220

9612629018

45 C10-SR 3s2a

3547

C10-SR

41000 to 45000

56000

22450

9612629019

50 C10-SR 3s2a

3547

C10-SR

46000 to 50000

62000

22990

Click here for technical specifications for each item

Capacity l/h

Tetra Plex Plate Heat Exchangers

Yoghurt Milk Pasteurization

General
The heat exchangers are calculated to handle some variations in inlet and outlet temperatures. The outlet temperature is controlled by bypassing a part
of the flow over the regenerative. A cooling section is included. This is used during starting up and circulation and gives also the possibility to cool milk to
5C if it for any reason should be stored. Each plate heat exchanger can handle a range of capacities, see below table.

95

43

HW

2
IW

95

Hom.

Product
Milk. Total solids up to 18%. Total pressure drop for product 250-300 kPa.
Temperature program
4 - 95 - 43 (5) C
Acceptable variations in temperatures
Inlet temperature: 3-8C
Pasteurization temperature: 90-97C
Outlet temperature: 40-45C
Heating media
Hot water from external source with a temperature of maximum 2C above pasteurization temperature. Heat load is given for conti nous running at the
highest capacity in the range.
Cooling media
No cooling is needed during normal continous running. Cooling media is only needed when cooling up 5C outlet temperature and a t starting up and
circulation. Ice water of 2C . Pressure drop for cooling media in heat exchanger is max. 150 kPa.

Note!

Item

File name

Alsis
code

Product
HE type

Capacity l/h

Heating
flow l/h

Cooling
flow l/h

Transfer
price EUR

9612629020

02 C3-SR 4s2a

3544

C3-SR

1000 to 2000

2700

4230

9612629021

03 MS6-SR 4s2a

3552

MS6-SR

2000 to 3000

4000

6010

9612629022

04 MS6-SR 4s2a

3552

MS6-SR

3000 to 4000

6000

6510

9612629023

05 MS6-SR 4s2a

3552

MS6-SR

4000 to 5000

7000

6950

9612629024

06 MS6-SR 4s2a

3552

MS6-SR

5000 to 6000

8000

7310

9612629025

08 MS6-SR 4s2a

3552

MS6-SR

6000 to 8000

10000

7860

9612629026

10 C6-SR 4s2a

3545

C6-SR

9000 to 10000

12000

11600

9612629027

12 C6-SR 4s2a

3545

C6-SR

11000 to 12000

15000

12530

9612629028

15 C6-SR 4s2a

3545

C6-SR

13000 to 15000

18000

13790

9612629029

20 C8-SR 4s2a

3546

C8-SR

16000 to 20000

25000

16120

9612629030

25 C8-SR 4s2a

3546

C8-SR

21000 to 25000

31000

17610

Click here for technical specifications for each item

Cream Pasteurization, Warm Cream, 80% Heat Recovery

Tetra Plex Plate Heat Exchangers

General
The heat exchangers are calculated to handle some variations in inlet and outlet temperatures.
Cooling is done in 2 steps, first cooling with countercurrent flow and final cooling with cocurrent flow. Same ice water is used in both steps.
Each plate heat exchanger can handle a range of capacities, see below table.

95

HW

95

IW - 2
60

Product
Cream. Fat content 35-42%. Total pressure drop for product 200 kPa.
Temperature program
60 - 95 - 8C
Acceptable variations in temperatures
Inlet temperature: 55-65C
Pasteurization temperature: 90-95C
Outlet temperature: 6-8C
Heating media
Hot water from external source with a temperature of maximum 2C above pasteurization temperature.
Heat load is given for continous running. Heat load is doubled during start up.
Cooling media
Ice water of 2C. Pressure drop for cooling media in heat exchanger is max.150 kPa.
Cooling is done in 2 steps, first cooling with countercurrent flow and final cooling with cocurrent flow. Same ice water is used in both steps.
Cooling load is given for the case of a product inlet temperature of 60C and outlet temperature of 8C.

Item

File name

Alsis
code

Product
HE type

Heating
flow l/h

Cooling
flow l/h

Transfer
price EUR

9612629031

1 C3-SR 4s1a

3544

C3-SR

1000

1400

1500

9612629032

2 MS6-SR 4s1a

3552

MS6-SR

1000 to 2000

3000

6000

6070

9612629033

3 MS6-SR 4s1a

3552

MS6-SR

2000 to 3000

4000

9000

6630

3800

9612629034

4 MS6-SR 4s1a

3552

MS6-SR

3000 to 4000

6000

12000

7290

9612629035

5 MS6-SR 4s1a

3552

MS6-SR

4000 to 5000

7000

15000

7850

Click here for technical specifications for each item

Capacity l/h

Note!

Tetra Plex Plate Heat Exchangers

Cream Pasteurization, Cold Cream, 80% Heat Recovery

General
The heat exchangers are calculated to handle some variations in inlet and outlet temperatures.
Each plate heat exchanger can handle a range of capacities, see below table.

95

HW

95

IW - 2
10

Product
Cream. Fat content 35-42%. Total pressure drop for product 200 kPa.
Temperature program
10 - 95 - 8C
Acceptable variations in temperatures
Inlet temperature: 5-10C
Pasteurization temperature: 90-95C
Outlet temperature: 6-8C
Heating media
Hot water from external source with a temperature of maximum 2C above pasteurization temperature. Heat load is given for conti nous running. Heat
load is doubled during start up.
Cooling media
Ice water of 2C. Pressure drop for cooling media in heat exchanger is max.150 kPa. Cocurrent flow is used. Cooling load is giv en for the case of a
product inlet temperature of 10C and outlet temperature of 8C.

Note!

Item

9612629036

File name

01 C3-SR 3s1a

Alsis
code

Product
HE type

3544

C3-SR

Heating
flow l/h

Cooling
flow l/h

1000

1500

3500

3410

Capacity l/h

Transfer
price EUR

9612629037

02 MS6-SR 3s1a

3552

MS6-SR

1000 to 2000

3000

6000

5310

9612629038

03 MS6-SR 3s1a

3552

MS6-SR

2000 to 3000

4000

10000

6020

9612629039

04 MS6-SR 3s1a

3552

MS6-SR

3000 to 4000

6000

14000

6630

9612629040

05 MS6-SR 3s1a

3552

MS6-SR

4000 to 5000

7000

18000

7130

9612629041

06 C6-SR 3s1a

3545

C6-SR

5000 to 6000

9000

18000

11340

9612629042

07 C6-SR 3s1a

3545

C6-SR

6000 to 7000

10000

21000

12200

9612629043

10 C8-SR 3s1a

3546

C8-SR

8000 to 10000

14000

30000

15010

Click here for technical specifications for each item

Tetra Plex Plate Heat Exchangers

Fruit Concentrate Cooling

General
The heat exchangers are calculated to handle some variations in inlet temperature.

PG
-9

-5

25

Product
Orange concentrate 65 Bx. Maximum length of the fibres 1 mm
Pineapple concentrate 65 Bx. Maximum length of the fibres 1 mm.
Pressure drop 300-400 kPa.
Temperature program
25 - -5 C
Cooling media
Circulating Propylene Glycole

Item

9612629044

Note!

File name

Alsis
code

0450 C6-SR 1s1a

3545

Product
HE type

C6-SR

Capacity l/h

450000

Heating
flow l/h

Cooling
flow l/h

1700

Transfer
price EUR

4560

9612629045

0550 C6-SR 1s1a

3545

C6-SR

550000

2500

4690

9612629046

0900 C6-SR 1s1a

3545

C6-SR

900000

2600

4820

9612629047

1000 C6-SR 1s1a

3545

C6-SR

1000000

5100

4950

Click here for technical specifications for each item

10

Tetra Plex Plate Heat Exchangers

Fruit Juice Pasteurization, 85% Heat Recovery

General
The heat exchangers are calculated to handle some variations in inlet and outlet temperatures.
Each plate heat exchanger can handle a range of capacities, see table below.

95

25

HW

CW
15

95

15
Product
Fruit juice with up to 5% pulp and fibres up to 1 mm length.
Total pressure drop for product 250-350 kPa.
Temperature program
15 - 95 - 25C
Acceptable variations in temperatures
Inlet temperature: 12-19C
Pasteurization temperature: 90-98C
Heating media
Hot water from external source with a temperature of maximum 5C above pasteurization temperature.
Heat load is given for continous running. Heat load is doubled during start up.
Cooling media
Cold water of 15C. Pressure drop for cooling media in heat exchanger is max. 150 kPa.
Cooling load is given for the case of a product inlet temperature of 15C.

Item

File name

Alsis
code

Product
HE type

Capacity l/h

Note!
Heating
flow l/h

Cooling
flow l/h

Transfer
price EUR

9612629048

01,3 C6-SR 3s1a

3545

C6-SR

1000 to 1300

1500

2500

6510

9612629049

03,0 C6-SR 3s1a

3545

C6-SR

1400 to 3000

3500

3000

7670

9612629050

06,5 C6-SR 3s1a

3545

C6-SR

3100 to 6500

7700

5000

9130

9612629051

13,0 C8-SR 3s1a

3546

C8-SR

6600 to 13000

17000

6000

12910

Click here for technical specifications for each item

11

Tetra Plex Plate Heat Exchangers

Fruit Juice Pasteurization, with Deaeration

General
The heat exchangers are calculated to handle some variations in inlet and outlet temperatures as well as to compensate for the temperature loss in a
deaerator.
Outlet for deaerator is included.
Each plate heat exchanger can handle a range of capacities, see table below.

95

25

HW

CW
15

95

15

Deo.

Product
Fruit juice with up to 5% pulp and fibres up to 1 mm length.
Total pressure drop for product 250-350 kPa.
Temperature program
15 - 55/50 - 90 - 25C
Acceptable variations in temperatures
Inlet temperature: 12-19C
Pasteurization temperature: 90-98C
Heating media
Hot water from external source with a temperature of maximum 5C above pasteurization temperature.
Heat load is given for continous running with deaerator. Heat load is doubled during start up.
Cooling media
Cold water of 15C. Pressure drop for cooling media in heat exchanger is max. 150 kPa.
Cooling load is given for the case of a product inlet temperature of 15C.

Item

File name

Alsis
code

Product
HE type

Capacity l/h

Note!
Heating
flow l/h

Cooling
flow l/h

Transfer
price EUR

9612629052

01,25 C6-SR 4s1a

3545

C6-SR

1000 to 1250

1800

1700

7360

9612629053

03,00 C6-SR 4s1a

3545

C6-SR

1300 to 3000

3500

2000

8520

9612629054

06,50 C6-SR 4s1a

3545

C6-SR

3000 to 6500

8000

3000

9760

9612629055

13,00 C8-SR 4s1a

3546

C8-SR

6600 to 13000

17000

4000

13560

Click here for technical specifications for each item

12

Tetra Plex Plate Heat Exchangers

Fruit Juice Pasteurization, Hot Filling

General
The heat exchangers are calculated to handle some variations in inlet and outlet temperatures as well as to compensate for the temperature loss in a
deaerator.
Outlet for deaerator is included.
The cooler is big enough to cool to 38C if product goes in return
Each plate heat exchanger can handle a range of capacities, see table below.

85 85

95

38

HW

TW
30

95

15

TW
30

Deo.

Product
Fruit juice with up to 5% pulp and fibres up to 1 mm length.
Total pressure drop for product 250 kPa.
Temperature program
15 - 55/50 - 90 - 85 (-38)C
Acceptable variations in temperatures
Inlet temperature: 12-19C
Pasteurization temperature: 90-98C
Heating media
Hot water from external source with a temperature of maximum 5C above pasteurization temperature.
Heat load is given for continous running with deaerator. Heat load is doubled during start up.
Cooling media
Tower water of 30C. Pressure drop for cooling media in heat exchanger is max. 150 kPa.
Cooling load is given for the case of a product inlet temperature of 15C.
Figures in parenthesis are for the case of cooling to 38C

Note!

Item

File name

Alsis
code

Product
HE type

Capacity l/h

Heating
flow l/h

Cooling
flow l/h

Transfer
price EUR

9612629056

04,7 C6-SR 4s1a

3545

C6-SR

3000 to 4700

600

1000

9240

9612629057

07,8 C6-SR 4s1a

3545

C6-SR

4800 to 7800

9600

1500

10880

9612629058

10,4 C8-SR 4s1a

3546

C8-SR

7900 to 10400

14150

Click here for technical specifications for each item

13

Plate Heat Exchangers - Gasketed

CIP Heating
1.1

.
General
The heat exchangers are calculated to handle some variations in inlet temperature.
Each plate heat exchanger can handle a range of capacities, see table below.

TD 900-022

A = CIP out, B = CIP in, C = Condensate out, D = steam in


Product
CIP solutions.
Pressure drop 100-150 kPa.
Temperature program
50-70C
Heating media
Steam of 3 bar.
Item

File name

Capacity l/h

9612629059

06 MS6-SBL

6000

9612629060

12 MS6-SBL

9612629061

Heating media

Transfer

No. of sections

Alsis code

250

3542

1430

7000 to 12000

500

3542

1490

18 MS10-SBL

13000 to 18000

750

3543

2480

9612629062

24 MS10-SBL

19000 to 24000

1000

3543

2530

9612629063

30 MS10-SBL

25000 to 30000

1200

3543

2580

9612629064

36 MS10-SBL

31000 to 36000

1500

3543

2630

steam kg/h

price EUR

9612629082

10 T6-SR

10000

400

3705

2650

9612629083

15 T6-SR

15000

600

3705

2760

9612629084

20 T6-SR

20000

800

3705

2860

9612629085

25 T6-SR

25000

1000

3705

2910

9612629086

30 T6-SR

30000

1200

3705

3010

9612629087

40 T6-SR

40000

1500

3705

3110

Click here for technical specifications for each item

1.1.69

You might also like