You are on page 1of 20

Packaged Air Conditioners

CONTENTS
Description ........................................................................ 3
Typical Unit Configuration ................................................. 3
Features ............................................................................ 4
Options Available ............................................................... 4
Simplicity Controls ............................................................ 5
Selection Method .............................................................. 5
Product Data ..................................................................... 6
Cooling Performance Data (85F Ambient) ...................... 7
Cooling Performance Data (95F Ambient) ...................... 8
Cooling Performance Data (105F Ambient) .................... 9

Cooling Performance Data (115F Ambient) ................. 10


Cooling Performance Data (125F Ambient) ................. 11
Fan Performance Data ................................................... 12
Drive & Pulley Data ........................................................ 13
Electrical Data ................................................................ 13
Dimensional Data DMS 090, 100, 120 .......................... 14
Dimensional Data DMS 150 .......................................... 15
Wiring Diagram ............................................................... 16
Guide Specifications ...................................................... 17
Maintenance ................................................................... 19

PRODUCT NOMENCLATURE
D

Product Category
D = A/C, Single
package
Product Identifier
M = R22, Std. efficiency
Series Name
S = Saber
Nominal Cooling
Capacity
090 = 7.5 Tons
100 = 8.5 Tons
120 = 10.0 Tons
150 = 12.5 Tons
Mode
C00 = Cooling only
Motor Option
A = Standard motor
B = Over size motor

120

C00 A

1
Product Generation
1 = First generation

Field Installed Options


1 = No option installed
2 = 9 kW electric heater
3 = 18 kW electric heater
4 = Fresh air damper
5 = 36 kW electric heater
(DMS 150 only)
Factory Installed Options
A = No options Installed
B = Heresite coating on
condenser coil
C = Heresite coating on
evaporator coil
D = 2 Aluminium washable
filter
E = Cu / Cu condenser coil
F = Cu / Cu evaporator coil
G = Disconnect switch
I = BMS
J = High speed drive
K = Low speed drive
M = Dirty filter switch
N = Low ambient kit
P = Smoke detector
Q = 9 kW Heater
R = 18 kW Heater
S = Fresh Air Damper
T = 36 kW Heater
(DMS 150 only)

Power Supply
4 = 380 - 415V / 3Ph / 50Hz

Technical Sales Guide : 036 - 2005 (1005)

Page 2

Packaged Air Conditioners

DESCRIPTION
Models DMS 090, 100, 120 & 150 (7.5, 8.5, 10 & 12.5 Nominal Tons)
YORK Saber units are single package high efficiency rooftops. DMS models 090, 100 & 120 provide efficient
cooling with single refrigerant circuits, whereas model 150 has independent dual refrigerant circuits for
efficient part load operation. Although the units are primarily designed for roof top installation they can also be
slab mounted at ground level or set on steel beams above finished roofs. A wide variety of factory mounted
options and field installed accessories make the Saber units suitable for almost every application.
YORK Saber units are designed to operate satisfactorily in a wide range of ambient temperatures from 125F
(52C) down to 50F (10C) as standard.
All standard units include :
z

Powder paint finish that meets ASTM B 1l7, 750 hour salt spray standards.

Refrigeration circuit(s) with expansion valves, filter-driers, high and low pressure switches and freezestats.

High efficiency Hermetic Reciprocating compressors.

Side by side return / supply configuration.

Belt drive blower motor with variable pitch pulley.

Totally enclosed IP54 Evaporator & Condenser motors with Class F insulation.

Microprocessor based SimplicityTM control board.

25% fresh air intake connection only.

Copper tube / aluminum fin coils.

2 inch disposable filters.

Single point power connection.

Complete factory package - tested, charged and wired.

1 year limited warranty on the complete unit and additional 4 year warranty on compressors.

Typical Unit Configuration

Technical Sales Guide : 036 - 2005 (1005)

Page 3

Packaged Air Conditioners

FEATURES
Saber units are self contained and assembled on full
perimeter base with rigging holes in the four corners for
overhead rigging. Every unit is completely piped, wired,
charged and tested at the factory to simplify the field
installation and to provide years of dependable operation.
All models are suitable for horizontal duct connections. The
power supply can be routed into the control box through a
gland in the wiring panel on the front of the unit.
Compressors are hermetic reciprocating type, of an
advanced design ensuring high Energy Efficiency Ratio, less
noise, less vibration and outstanding endurance. Crankcase
heaters, internal pressure relief valve, internal compressor
motor protection and sight glass are standard on all
compressors. Every refrigerant circuit includes an expansion
valve, a liquid line filter drier, a discharge line high pressure
switch, suction line freezestat and low pressure switch to
protect all system components.
Each supply air blower is equipped with a belt drive that
can be adjusted to meet the exact requirements of the
application. A high or low static drive option is available for
applications with a higher or lower airflow and / or static
pressure requirement. All evaporator blower motors are
weatherproof TEFC IP54 with Class F insulation.

All Saber units are equipped with a control panel which


includes all the necessary operating and safety controls
that are needed for reliable operation. Compressors are
protected with internal thermal overload and fan motors with
external overload. Transformers and control circuits are
protected with fuses.
The operation of the package units is masterminded by the
microprocessor based SimplicityTM control board which
provides both intelligent monitoring and easy diagnostics,
as featured below :
z

Anti Short Cycle Protection : To aid compressor


life, an anti short cycle delay is incorporated into the
standard controls. Compressor reliability is further
ensured by programmable minimum run times. For
testing, the anti short cycle delay can be temporarily
overridden with the push of a button.

Fan Delays : Fan on and fan off delays are fully


programmable. Furthermore, the heating and cooling
fan delay times are independent of one another. All units
are programmed with default values based upon their
configuration of cooling and heating.

Safety Monitoring : High flow pressure switches and


suction line freezestats are supplied on all units to
protect against loss of charge and the occurrence of
coil frosting. The control board monitors the high and
low-pressure switches and the freezestats. The unit
control board will alarm on compressor lockouts and
repeated limit switch trips on electric heat units.

Nuisance Trip Protection : To prevent nuisance trouble


calls, the control board uses a "three times, you're out"
philosophy. The high and low pressure switches and
the freezestats must trip three times within two hours
before the unit control board will lock out the associated
compressor.

On Board Diagnostics : Each alarm will energize a


trouble light on the thermostat, if so equipped, and flash
an alarm code on the control board LED. Each high
and low pressure switch alarm as well as each
freezestat alarm has its own flash code. The control
board saves the five most recent alarms in memory,
which can be reviewed at any time.

Nonvolatile Memory : Alarms and programmed values


are retained through the loss of power.

A fixed outdoor air intake connection that is designed for


25% fresh air intake is available as standard. Fresh air
dampers are optional for field / factory installation.
Condenser fans are propeller type of heavy duty
construction, dynamically balanced and suitable to operate
up to 80C ambients. Fans are driven by TEAO IP54 motors
with Class F insulation. The fan blade pitch angle is designed
for maximum airflow and minimum noise.
The evaporator and condenser coils are constructed of
seamless internally enhanced copper tubes which are
mechanically bonded to aluminium fins. Heat exchangers
are tested up to a pressure of 250 psig (evaporator) and
450 psig (condenser).
A nonmetallic drain pan with bottom condensate removal
ensures zero water retention, no corrosion and ensures
healthy Indoor Air Quality (IAQ).
All units have long lasting powder paint cabinets with a
robust 40 microns thick paint coating that meets ASTM B
117 standards and are suitable for 750 hour salt spray test,
ensuring excellent resistance to corrosion in the harshest
conditions. The cabinet is internally lined by a 1 thick layer
of fibre glass insulation that minimizes heat gain and
improves IAQ.
All electric heat models (heaters field / factory installed)
are wired for a single power source and include a bank of
nickel chromium elements mounted at the discharge of the
supply air blower to provide a high velocity and uniform
distribution of air across the heating elements. Every
element is fully protected against excessive current and
temperature by High Temperature Thermal Cut out (HTTC).

Technical Sales Guide : 036 - 2005 (1005)

OPTIONS AVAILABLE
z

Heresite Coated Evaporator and Condenser Coils


(factory installed) : Coating is applied by spray for
maximum corrosion protection.

Copper Tube And Copper Fin Evaporator And


Condenser Coils (factory installed).

Filter Options : Standard units are shipped installed


with 2" throw away filters. 2" washable aluminium filters
are offered as a factory installed option.

Page 4

Packaged Air Conditioners

SIMPLICITY

TM

CONTROLS

Low Cost Open Architecture for


Light Commercial and Residential Applications

High And Low Speed Drive (factory installed) :


Includes a belt and blower pulley to upgrade or
downgrade the blower performance.

Manual Fresh Air Dampers

Electric Heaters : wired for single point power supply.


These nickel chromium heater elements are provided
with limit and automatic reset capability to prevent
operation at excessive temperatures.

Main Disconnect Switch (factory installed) : Suitably


sized in accordance with the applicable electrical codes.

Thermostat (field installed) : For 1 / 2 stage cooling


only (7.5 to 10 TR models) or 2 stage heat & 1 / 2
stage cool configurations (12.5 TR models).

BMS Controls : York's Saber series units offer factory


mounted BMS controls - consult your local sales office
for details.

Low Ambient Kit (factory installed) : For unit to work


satisfactorily down to 32 F (0C).

Smoke Detectors for supply air & return air (factory


installed) : The smoke detectors stop operation of the
unit by interrupting power to the control board if smoke
is detected within the air compartment.

Dirty Filter Switch (factory installed) : This kit includes


a differential pressure switch that energizes the fault
light on the unit thermostat, indicating that there is an
abnormally high pressure drop across the filters.

Technical Sales Guide : 036 - 2005 (1005)

The HPS, LPS and FS are


monitored independently for each
circuit.

Stores the last 5 alarms in non


volatile memory

Alarms are recalled with a single


button push even after the power
has been removed and returned.

Reset anti short cycle delays


with a single button push

Reduces nuisance calls by


using Three Times And You Are
Out logic on all safeties before
a permanent lockout occurs.

SELECTION METHOD
The following steps illustrate the selection of a DMS Package
Unit for a Total Capacity requirement of 100 MBh and an
Airflow of 3500 cfm. The unit operating parameters are:

Entering Air Temperature : 80/67F (DB/WB)


Ambient Temperature : 115F
Fan External Static Pressure : 1.0 inch wg

Step 1 Select the Unit Model by referring to the "Cooling


Performance Data" table for 115F ambient on page
10. Scroll down the "Total Capacity" and "Entering
Air WBT" columns until 100 MBh (or a value close
to it) is found at 67F WB for an airflow close to
3500 cfm. The selected Model is DMS 120 giving
Total Capacity 106.2 MBh with the actual
Compressor Power Input being 13.4 kW.
Step 2 For the Sensible Capacity read the value at the
intersection of the same row (as the WB in step 1)
and the 80 DB column on the right. The Sensible
Capacity for the unit in this example is 80.7 MBh.
Step 3 Refer "Fan Performance Data" on page 12 to check
the motor size and fan rpm. Scroll down the 1.0
inch wg ESP" column to the 3500 cfm row for
DMS 120. The fan speed is 1028 rpm and fan power
input 1.28 kW. The white colour of the box indicates
that the standard 2.2 kW motor is sufficient.
Step 4 To arrive at the correct Drive Set to be ordered with
the unit, refer "Drive & Pulley Data" on page 13.
Use the fan rpm from step 3 to select the correct
drive set. The package unit in this example will
require a standard drive set.

Page 5

Packaged Air Conditioners

PRODUCT DATA
MODEL DMS
EER
Ratings @ARI
Conditions

Btu/W
MBH
kW
HP
kW
MBH
kW
MBH
kW

Capacity
Compressor
Power Input

Electric
Heating
Capacities

Option 1
Option 2

90
9.9
91.5
26.8
10.3
7.7
30.7
9.0
61.4
18.0

Tube / Fins
Evaporator
Coil

Area

ft
m
fpi
mm

8.4
0.8

fpi
mm
ft
m

16
1.6

hp
kW
hp
kW

2
1.5
3
2.2

Tube / Fins
Fin Spacing
Area

Blower Fan &


Motor

Fan Type
Fan Quantity
Motor Type
Motor
Size

Condenser
Fan & Motor

Compressor

Refrigerant

std
xtd

Type
Quantity
Motor Type
Motor size
Quantity
Type
Quantity
Type
Number of Circuits
Charge Per
Circuit
Height

Dimensions

Width
Length
h x l x d - Qty

Filters
h x l x d - Qty
Weights

Basic Unit

120
8.8
122.3
35.8
15.7
11.7
30.7
9.0
61.4
18.0

150
8.8
144.5
42.4
18.1
13.5
61.4
18.0
122.8
36.0

Enhanced Copper / Aluminum Louvered

Fin Spacing

Condenser
Coil

100
9.3
111.2
32.6
13.7
10.2
30.7
9.0
61.4
18.0

hp
kW
#
#

Technical Sales Guide : 036 - 2005 (1005)

2
1.5
3
2.2

3
2.2
4
3.0

10.0
4.5

12.0
5.5
45.3
1150.0
59.2
1503.0
76.1
1934.0
20 x 20 x 2 - 2#
500 x 500 x 50 - 2#
12 x 20 x 2 - 2#
300 x 500 x 50 - 2#

12.5
5.7

882
401

935
425

1012
460

12.2
1.1
12
2.1
12
2.1
18.7
1.7

4
3.0
5.5
4.0

Heavy Duty Propeller Fan


1
6 Pole, Class F Insulation, Totally Enclosed Fan Cooled, IP54, 920 rpm
1.1
0.75
1
Hermetic Reciprocating
1
R - 22
1

lbs
kgs
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
lbs
kg

8.4
8.9
0.8
0.8
14
1.8
Enhanced Copper / Aluminum Louvered
14
1.8
14.9
1.4
Forward Curved Centrifugal - DIDW
1
4 Pole, Class F Insulation, Totally Enclosed Fan Cooled, IP54, 1400 rpm

2.2
1.5

2
7.8
3.5
52.5
1333.0
77.8
1976.0
89.0
2271.0
24 x 20 x 2 - 2#
600 x 500 x 50 - 2#
20 x 20 x 2 - 2#
500 x 500 x 50 - 2#
1485
675

Page 6

Packaged Air Conditioners


AMBIENT 85F (29.4C)

COOLING PERFORMANCE DATA


85 F ( 29.4 C)
Model
DMS

Air Flow Rate


cfm

l/s

2250

1062

2500

1180

3000

1416

3250

1534

2500

1180

3000

1416

3400

1604

4000

1888

3000

1416

3500

1652

4000

1888

4800

2265

3750

1770

4500

2124

5000

2360

6000

2831

90

100

120

150

Note :

Entering Air
WBT

Total Capacity

F
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63

MBh
94.3
91.7
89.0
86.1
96.1
93.4
90.6
87.7
99.0
96.2
93.3
90.2
100.2
97.3
94.4
91.3
113.8
110.7
107.5
104.2
117.6
114.4
111.0
107.6
120.1
116.8
113.3
109.8
123.1
119.7
116.1
112.4
126.5
123.1
119.6
116.0
129.9
126.4
122.7
119.0
132.6
129.0
125.3
121.4
135.9
132.2
128.4
124.4
148.0
144.0
139.8
135.6
152.8
148.6
144.3
139.8
155.4
151.1
146.7
142.1
159.5
155.1
150.6
145.8

C
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2

kW
27.6
26.9
26.1
25.2
28.2
27.4
26.5
25.7
29.0
28.2
27.3
26.4
29.4
28.5
27.7
26.8
33.4
32.4
31.5
30.5
34.5
33.5
32.5
31.5
35.2
34.2
33.2
32.2
36.1
35.1
34.0
33.0
37.1
36.1
35.1
34.0
38.1
37.0
36.0
34.9
38.9
37.8
36.7
35.6
39.8
38.8
37.6
36.5
43.4
42.2
41.0
39.7
44.8
43.6
42.3
41.0
45.5
44.3
43.0
41.7
46.8
45.5
44.1
42.7

Compressor
Power
Input
kW
7.1
7.0
6.9
6.9
7.1
7.0
7.0
6.9
7.1
7.1
7.0
7.0
7.2
7.1
7.1
7.0
9.4
9.3
9.1
9.0
9.5
9.4
9.3
9.1
9.6
9.5
9.4
9.2
9.7
9.6
9.5
9.3
10.7
10.6
10.4
10.3
10.9
10.7
10.6
10.4
11.0
10.8
10.7
10.5
11.1
11.0
10.8
10.6
12.4
12.2
12.0
11.8
12.6
12.4
12.2
12.0
12.7
12.5
12.3
12.1
12.9
12.7
12.5
12.3

82 (27.8)
MBh
kW
61.7
18.1
66.9
19.6
72.1
21.1
77.1
22.6
64.9
19.0
70.6
20.7
76.2
22.3
81.7
23.9
71.1
20.8
77.7
22.8
84.1
24.7
90.2
26.4
74.1
21.7
81.1
23.8
88.0
25.8
91.3
26.8
71.7
21.0
77.5
22.7
83.3
24.4
88.9
26.1
77.9
22.8
84.6
24.8
91.3
26.8
97.8
28.7
82.7
24.2
90.2
26.4
97.5
28.6
104.7
30.7
89.7
26.3
98.1
28.7
106.4
31.2
112.4
33.0
81.5
23.9
88.4
25.9
95.2
27.9
101.8
29.8
87.6
25.7
95.3
27.9
103.0
30.2
110.5
32.4
93.4
27.4
102.0
29.9
110.5
32.4
118.9
34.8
102.2
30.0
112.0
32.8
121.9
35.7
124.4
36.5
93.5
27.4
101.2
29.7
108.9
31.9
116.4
34.1
101.4
29.7
110.4
32.3
119.1
34.9
127.8
37.5
106.5
31.2
116.1
34.0
125.7
36.8
135.1
39.6
116.1
34.0
127.2
37.3
138.2
40.5
145.8
42.7

Sensible Capacity
Entering Air DBT F (C)
80 (26.7)
78 (25.6)
MBh
kW
MBh
kW
57.0
16.7
52.4
15.3
62.3
18.2
57.6
16.9
67.4
19.8
62.7
18.4
72.4
21.2
67.8
19.9
59.8
17.5
54.6
16.0
65.4
19.2
60.3
17.7
71.0
20.8
65.9
19.3
76.5
22.4
71.4
20.9
65.0
19.1
59.0
17.3
71.6
21.0
65.6
19.2
78.1
22.9
72.1
21.1
84.5
24.8
78.5
23.0
67.6
19.8
61.1
17.9
74.6
21.9
68.1
20.0
81.5
23.9
75.1
22.0
88.4
25.9
81.9
24.0
66.6
19.5
61.4
18.0
72.4
21.2
67.3
19.7
78.1
22.9
73.0
21.4
83.8
24.6
78.6
23.0
71.9
21.1
65.9
19.3
78.6
23.0
72.6
21.3
85.3
25.0
79.3
23.2
91.8
26.9
85.8
25.1
76.0
22.3
69.3
20.3
83.4
24.5
76.7
22.5
90.8
26.6
84.0
24.6
98.0
28.7
91.3
26.7
81.9
24.0
74.2
21.7
90.3
26.5
82.6
24.2
98.7
28.9
90.9
26.7
106.9
31.3
99.2
29.1
75.5
22.1
69.4
20.3
82.3
24.1
76.3
22.4
89.1
26.1
83.1
24.3
95.7
28.1
89.7
26.3
80.6
23.6
73.7
21.6
88.4
25.9
81.4
23.9
96.0
28.2
89.1
26.1
103.5
30.3
96.6
28.3
85.6
25.1
77.8
22.8
94.2
27.6
86.4
25.3
102.7
30.1
94.9
27.8
111.1
32.6
103.3
30.3
93.1
27.3
84.0
24.6
103.0
30.2
93.9
27.5
112.8
33.1
103.7
30.4
122.4
35.9
113.3
33.2
86.6
25.4
79.7
23.4
94.4
27.7
87.5
25.6
102.1
29.9
95.2
27.9
109.6
32.1
102.7
30.1
93.4
27.4
85.4
25.0
102.4
30.0
94.4
27.7
111.1
32.6
103.1
30.2
119.8
35.1
111.8
32.8
97.8
28.7
89.0
26.1
107.4
31.5
98.7
28.9
116.9
34.3
108.2
31.7
126.3
37.0
117.6
34.5
106.0
31.1
95.9
28.1
117.0
34.3
106.9
31.3
128.0
37.5
117.9
34.6
138.7
40.7
128.6
37.7

76 (24.4)
MBh
kW
47.7
14.0
52.9
15.5
58.1
17.0
63.1
18.5
49.5
14.5
55.2
16.2
60.8
17.8
66.3
19.4
53.0
15.5
59.6
17.5
66.1
19.4
72.5
21.2
54.7
16.0
61.7
18.1
68.6
20.1
75.5
22.1
56.3
16.5
62.2
18.2
67.9
19.9
73.5
21.5
59.9
17.5
66.6
19.5
73.2
21.5
79.7
23.4
62.5
18.3
70.0
20.5
77.3
22.7
84.5
24.8
66.5
19.5
74.9
21.9
83.2
24.4
91.5
26.8
63.3
18.6
70.2
20.6
77.0
22.6
83.6
24.5
66.7
19.6
74.5
21.8
82.2
24.1
89.7
26.3
70.0
20.5
78.6
23.1
87.1
25.5
95.5
28.0
74.9
22.0
84.8
24.8
94.6
27.7
104.3
30.6
72.9
21.4
80.6
23.6
88.3
25.9
95.8
28.1
77.4
22.7
86.3
25.3
95.1
27.9
103.8
30.4
80.3
23.5
89.9
26.4
99.5
29.2
108.9
31.9
85.8
25.1
96.8
28.4
107.8
31.6
118.5
34.7

These capacities are gross ratings. For net capacity deduct the heat of the supply air blower motor kW x 3.415 = MBH
Refer to the appropriate Blower Performance table for the kW of the supply air blower motor.

Technical Sales Guide : 036 - 2005 (1005)

Page 7

Packaged Air Conditioners


AMBIENT 95F (35C)

COOLING PERFORMANCE DATA


95 F (35 C)
Model
DMS

Air Flow Rate


cfm

l/s

2250

1062

2500

1180

3000

1416

3250

1534

2500

1180

3000

1416

3400

1604

4000

1888

3000

1416

3500

1652

4000

1888

4800

2265

3750

1770

4500

2124

5000

2360

6000

2831

90

100

120

150

Note :

Entering Air
WBT

Total Capacity

F
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63

MBh
89.9
87.3
84.6
81.9
91.5
88.9
86.1
83.3
94.2
91.5
88.7
85.7
95.3
92.6
89.7
86.7
108.5
105.5
102.4
99.2
112.0
108.9
105.7
102.4
114.3
111.2
107.9
104.4
117.1
113.8
110.4
106.9
120.2
116.9
113.6
110.1
123.3
119.9
116.5
112.9
125.8
122.3
118.8
115.1
128.8
125.3
121.6
117.8
141.8
137.9
133.9
129.7
146.2
142.2
138.0
133.7
148.6
144.5
140.3
135.8
152.5
148.3
143.9
139.3

C
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2

kW
26.3
25.6
24.8
24.0
26.8
26.0
25.2
24.4
27.6
26.8
26.0
25.1
27.9
27.1
26.3
25.4
31.8
30.9
30.0
29.1
32.8
31.9
31.0
30.0
33.5
32.6
31.6
30.6
34.3
33.4
32.4
31.3
35.2
34.3
33.3
32.3
36.1
35.1
34.1
33.1
36.9
35.9
34.8
33.7
37.8
36.7
35.7
34.5
41.5
40.4
39.2
38.0
42.8
41.7
40.4
39.2
43.6
42.4
41.1
39.8
44.7
43.5
42.2
40.8

Compressor
Power
Input
kW
7.6
7.6
7.5
7.4
7.7
7.6
7.5
7.5
7.8
7.7
7.6
7.5
7.8
7.7
7.6
7.6
10.1
10.0
9.8
9.7
10.3
10.1
10.0
9.8
10.4
10.2
10.1
9.9
10.5
10.4
10.2
10.0
11.6
11.4
11.2
11.1
11.7
11.6
11.4
11.2
11.9
11.7
11.5
11.3
12.0
11.9
11.7
11.5
13.4
13.2
13.0
12.7
13.6
13.4
13.2
13.0
13.7
13.5
13.3
13.1
13.9
13.7
13.5
13.2

82 (27.8)
MBh
kW
60.0
17.6
65.2
19.1
70.3
20.6
75.2
22.1
63.2
18.5
68.8
20.2
74.4
21.8
79.8
23.4
69.4
20.3
75.9
22.2
82.3
24.1
85.7
25.1
72.4
21.2
79.3
23.2
86.2
25.3
86.7
25.4
69.6
20.4
75.4
22.1
81.1
23.8
86.7
25.4
75.8
22.2
82.5
24.2
89.1
26.1
95.6
28.0
80.6
23.6
88.0
25.8
95.3
27.9
102.5
30.0
87.5
25.7
95.9
28.1
104.2
30.5
106.9
31.3
79.1
23.2
85.9
25.2
92.7
27.2
99.2
29.1
85.1
25.0
92.8
27.2
100.4
29.4
107.9
31.6
91.0
26.7
99.5
29.2
107.9
31.6
115.1
33.7
99.7
29.2
109.5
32.1
119.3
35.0
117.8
34.5
91.1
26.7
98.8
29.0
106.5
31.2
113.9
33.4
99.0
29.0
107.9
31.6
116.7
34.2
125.3
36.7
104.1
30.5
113.7
33.3
123.2
36.1
132.5
38.8
113.7
33.3
124.7
36.6
135.6
39.8
139.3
40.8

Sensible Capacity
Entering Air DBT F (C)
80 (26.7)
78 (25.6)
MBh
kW
MBh
kW
55.3
16.2
50.7
14.9
60.5
17.7
55.8
16.4
65.6
19.2
60.9
17.9
70.6
20.7
65.9
19.3
58.0
17.0
52.9
15.5
63.7
18.7
58.6
17.2
69.3
20.3
64.1
18.8
74.7
21.9
69.6
20.4
63.3
18.6
57.3
16.8
69.9
20.5
63.8
18.7
76.3
22.4
70.3
20.6
82.7
24.2
76.6
22.5
65.9
19.3
59.4
17.4
72.8
21.4
66.4
19.5
79.7
23.4
73.3
21.5
86.5
25.4
80.1
23.5
64.5
18.9
59.4
17.4
70.3
20.6
65.2
19.1
76.0
22.3
70.9
20.8
81.5
23.9
76.4
22.4
69.8
20.5
63.8
18.7
76.5
22.4
70.5
20.7
83.1
24.4
77.1
22.6
89.6
26.3
83.5
24.5
73.9
21.7
67.2
19.7
81.3
23.8
74.6
21.9
88.6
26.0
81.9
24.0
95.8
28.1
89.0
26.1
79.8
23.4
72.1
21.1
88.2
25.8
80.4
23.6
96.5
28.3
88.8
26.0
104.7
30.7
96.9
28.4
73.1
21.4
67.0
19.6
79.9
23.4
73.8
21.6
86.6
25.4
80.5
23.6
93.2
27.3
87.1
25.5
78.2
22.9
71.3
20.9
85.9
25.2
79.0
23.1
93.5
27.4
86.6
25.4
101.0
29.6
94.0
27.6
83.2
24.4
75.4
22.1
91.7
26.9
83.9
24.6
100.1
29.4
92.4
27.1
108.5
31.8
100.7
29.5
90.6
26.6
81.5
23.9
100.4
29.4
91.3
26.8
110.2
32.3
101.1
29.6
117.8
34.5
110.7
32.5
84.3
24.7
77.4
22.7
92.0
27.0
85.1
24.9
99.6
29.2
92.7
27.2
107.1
31.4
100.2
29.4
91.0
26.7
83.0
24.3
99.9
29.3
91.9
26.9
108.7
31.8
100.6
29.5
117.3
34.4
109.3
32.0
95.4
28.0
86.7
25.4
104.9
30.8
96.2
28.2
114.4
33.5
105.7
31.0
123.8
36.3
115.1
33.7
103.6
30.4
93.5
27.4
114.6
33.6
104.5
30.6
125.5
36.8
115.4
33.8
136.2
39.9
126.1
36.9

76 (24.4)
MBh
kW
46.0
13.5
51.2
15.0
56.3
16.5
61.3
18.0
47.8
14.0
53.4
15.7
59.0
17.3
64.4
18.9
51.3
15.0
57.8
16.9
64.3
18.8
70.6
20.7
53.0
15.5
59.9
17.6
66.8
19.6
73.6
21.6
54.2
15.9
60.0
17.6
65.7
19.3
71.3
20.9
57.8
16.9
64.4
18.9
71.1
20.8
77.5
22.7
60.4
17.7
67.9
19.9
75.1
22.0
82.3
24.1
64.3
18.9
72.7
21.3
81.0
23.7
89.2
26.1
60.9
17.9
67.8
19.9
74.5
21.8
81.1
23.8
64.3
18.9
72.0
21.1
79.6
23.3
87.1
25.5
67.6
19.8
76.1
22.3
84.6
24.8
92.9
27.2
72.5
21.2
82.3
24.1
92.1
27.0
101.6
29.8
70.5
20.7
78.2
22.9
85.9
25.2
93.3
27.4
75.0
22.0
83.9
24.6
92.6
27.2
101.3
29.7
77.9
22.8
87.5
25.6
97.0
28.4
106.3
31.2
83.3
24.4
94.3
27.6
105.2
30.8
115.9
34.0

These capacities are gross ratings. For net capacity deduct the heat of the supply air blower motor kW x 3.415 = MBH
Refer to the appropriate Blower Performance table for the kW of the supply air blower motor.

Technical Sales Guide : 036 - 2005 (1005)

Page 8

Packaged Air Conditioners


AMBIENT 105F (40.6C)

COOLING PERFORMANCE DATA


105 F (40.6 C)
Model
DMS

Air Flow Rate


cfm

l/s

2250

1062

2500

1180

3000

1416

3250

1534

2500

1180

3000

1416

3400

1604

4000

1888

3000

1416

3500

1652

4000

1888

4800

2265

3750

1770

4500

2124

5000

2360

6000

2831

90

100

120

150

Note :

Entering Air
WBT

Total Capacity

F
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63

MBh
85.4
83.0
80.4
77.7
86.9
84.4
81.8
79.1
89.4
86.8
84.1
81.3
90.4
87.8
85.1
82.2
103.0
100.2
97.3
94.2
106.1
103.2
100.2
97.1
108.1
105.2
102.1
98.9
110.4
107.5
104.4
101.1
113.5
110.4
107.2
103.9
116.3
113.2
109.9
106.4
118.6
115.4
112.0
108.4
121.4
118.1
114.6
110.9
135.3
131.6
127.8
123.8
139.4
135.6
131.6
127.4
141.6
137.7
133.7
129.4
145.2
141.2
137.0
132.6

C
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2

kW
25.0
24.3
23.6
22.8
25.5
24.7
24.0
23.2
26.2
25.4
24.6
23.8
26.5
25.7
24.9
24.1
30.2
29.4
28.5
27.6
31.1
30.3
29.4
28.5
31.7
30.8
29.9
29.0
32.4
31.5
30.6
29.6
33.3
32.4
31.4
30.5
34.1
33.2
32.2
31.2
34.8
33.8
32.8
31.8
35.6
34.6
33.6
32.5
39.7
38.6
37.5
36.3
40.9
39.7
38.6
37.4
41.5
40.4
39.2
37.9
42.6
41.4
40.1
38.9

Compressor
Power
Input
kW
8.3
8.2
8.1
8.0
8.4
8.3
8.2
8.1
8.5
8.4
8.3
8.2
8.5
8.4
8.3
8.2
10.9
10.7
10.5
10.4
11.0
10.9
10.7
10.5
11.2
11.0
10.8
10.6
11.3
11.1
10.9
10.8
12.5
12.3
12.1
11.9
12.7
12.5
12.2
12.0
12.8
12.6
12.4
12.2
13.0
12.8
12.6
12.3
14.5
14.3
14.1
13.8
14.7
14.5
14.3
14.0
14.9
14.6
14.4
14.2
15.1
14.8
14.6
14.3

82 (27.8)
MBh
kW
58.3
17.1
63.5
18.6
68.5
20.1
73.5
21.5
61.5
18.0
67.1
19.7
72.6
21.3
78.0
22.9
67.7
19.8
74.1
21.7
80.6
23.6
81.3
23.8
70.7
20.7
77.6
22.7
84.5
24.8
82.2
24.1
67.5
19.8
73.3
21.5
78.9
23.1
84.5
24.8
73.6
21.6
80.3
23.5
86.9
25.5
93.4
27.4
78.4
23.0
85.8
25.1
93.1
27.3
98.9
29.0
85.2
25.0
93.6
27.4
102.0
29.9
101.1
29.6
76.6
22.5
83.4
24.4
90.1
26.4
96.6
28.3
82.6
24.2
90.3
26.5
97.8
28.7
105.3
30.9
88.4
25.9
96.9
28.4
105.3
30.9
108.4
31.8
97.2
28.5
106.9
31.3
114.6
33.6
110.9
32.5
88.7
26.0
96.4
28.3
104.0
30.5
111.4
32.7
96.6
28.3
105.5
30.9
114.2
33.5
122.7
36.0
101.7
29.8
111.2
32.6
120.7
35.4
129.4
37.9
111.2
32.6
122.2
35.8
133.0
39.0
132.6
38.9

Sensible Capacity
Entering Air DBT F (C)
80 (26.7)
78 (25.6)
MBh
kW
MBh
kW
53.7
15.7
49.0
14.4
58.8
17.2
54.1
15.9
63.9
18.7
59.2
17.4
68.8
20.2
64.1
18.8
56.4
16.5
51.2
15.0
62.0
18.2
56.9
16.7
67.5
19.8
62.4
18.3
72.9
21.4
67.8
19.9
61.6
18.1
55.6
16.3
68.1
20.0
62.1
18.2
74.5
21.8
68.5
20.1
80.9
23.7
74.8
21.9
64.2
18.8
57.7
16.9
71.1
20.8
64.6
18.9
78.0
22.9
71.5
21.0
82.2
24.1
78.3
22.9
62.4
18.3
57.2
16.8
68.1
20.0
63.0
18.5
73.8
21.6
68.7
20.1
79.4
23.3
74.2
21.8
67.6
19.8
61.6
18.0
74.3
21.8
68.3
20.0
80.9
23.7
74.9
21.9
87.3
25.6
81.3
23.8
71.7
21.0
64.9
19.0
79.1
23.2
72.3
21.2
86.3
25.3
79.6
23.3
93.5
27.4
86.8
25.4
77.5
22.7
69.7
20.4
85.9
25.2
78.1
22.9
94.2
27.6
86.5
25.3
101.1
29.6
94.6
27.7
70.6
20.7
64.5
18.9
77.3
22.7
71.3
20.9
84.0
24.6
77.9
22.8
90.5
26.5
84.5
24.8
75.7
22.2
68.7
20.1
83.4
24.4
76.4
22.4
90.9
26.6
83.9
24.6
98.3
28.8
91.4
26.8
80.7
23.6
72.9
21.4
89.1
26.1
81.3
23.8
97.5
28.6
89.7
26.3
105.8
31.0
98.0
28.7
88.1
25.8
79.0
23.2
97.9
28.7
88.8
26.0
107.6
31.5
98.5
28.9
110.9
32.5
108.0
31.7
81.9
24.0
75.0
22.0
89.5
26.2
82.7
24.2
97.1
28.5
90.3
26.5
104.6
30.7
97.7
28.6
88.6
26.0
80.6
23.6
97.4
28.6
89.4
26.2
106.2
31.1
98.2
28.8
114.7
33.6
106.7
31.3
93.0
27.2
84.2
24.7
102.5
30.0
93.7
27.5
111.9
32.8
103.2
30.3
121.2
35.5
112.5
33.0
101.1
29.6
90.9
26.7
112.1
32.8
101.9
29.9
122.9
36.0
112.8
33.1
132.6
38.9
123.5
36.2

76 (24.4)
MBh
kW
44.3
13.0
49.5
14.5
54.5
16.0
59.5
17.4
46.1
13.5
51.7
15.2
57.2
16.8
62.7
18.4
49.6
14.5
56.1
16.4
62.5
18.3
68.8
20.2
51.3
15.0
58.2
17.1
65.1
19.1
71.8
21.0
52.1
15.3
57.9
17.0
63.6
18.6
69.1
20.3
55.6
16.3
62.2
18.2
68.8
20.2
75.3
22.1
58.2
17.1
65.6
19.2
72.9
21.4
80.1
23.5
62.0
18.2
70.4
20.6
78.8
23.1
86.9
25.5
58.4
17.1
65.2
19.1
71.9
21.1
78.4
23.0
61.8
18.1
69.5
20.4
77.0
22.6
84.4
24.7
65.1
19.1
73.5
21.5
81.9
24.0
90.2
26.4
69.9
20.5
79.7
23.4
89.4
26.2
98.9
29.0
68.1
20.0
75.8
22.2
83.4
24.4
90.8
26.6
72.6
21.3
81.4
23.9
90.1
26.4
98.7
28.9
75.5
22.1
85.0
24.9
94.5
27.7
103.8
30.4
80.8
23.7
91.8
26.9
102.6
30.1
113.3
33.2

These capacities are gross ratings. For net capacity deduct the heat of the supply air blower motor kW x 3.415 = MBH
Refer to the appropriate Blower Performance table for the kW of the supply air blower motor.

Technical Sales Guide : 036 - 2005 (1005)

Page 9

Packaged Air Conditioners


AMBIENT 115F (46.1C)

COOLING PERFORMANCE DATA


115 F (46.1 C)
Model
DMS

Air Flow Rate


cfm

l/s

2250

1062

2500

1180

3000

1416

3250

1534

2500

1180

3000

1416

3400

1604

4000

1888

3000

1416

3500

1652

4000

1888

4800

2265

3750

1770

4500

2124

5000

2360

6000

2831

90

100

120

150

Note :

Entering Air
WBT

Total Capacity

F
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63

MBh
80.7
78.4
76.0
73.4
82.1
79.7
77.2
74.6
84.3
81.9
79.3
76.6
85.3
82.8
80.2
77.5
97.0
94.5
91.8
88.9
99.7
97.1
94.4
91.5
101.4
98.8
96.0
93.1
103.4
100.8
98.0
95.0
106.7
103.7
100.7
97.5
109.2
106.2
103.0
99.8
111.3
108.2
104.9
101.6
113.8
110.6
107.3
103.8
128.6
125.1
121.4
117.6
132.3
128.7
124.9
121.0
134.4
130.6
126.8
122.8
137.6
133.8
129.8
125.7

C
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2

kW
23.7
23.0
22.3
21.5
24.1
23.4
22.6
21.9
24.7
24.0
23.3
22.5
25.0
24.3
23.5
22.7
28.4
27.7
26.9
26.1
29.2
28.5
27.7
26.8
29.7
29.0
28.2
27.3
30.3
29.5
28.7
27.9
31.3
30.4
29.5
28.6
32.0
31.1
30.2
29.2
32.6
31.7
30.8
29.8
33.4
32.4
31.4
30.4
37.7
36.7
35.6
34.5
38.8
37.7
36.6
35.5
39.4
38.3
37.2
36.0
40.3
39.2
38.0
36.8

Compressor
Power
Input
kW
9.1
8.9
8.8
8.6
9.1
9.0
8.9
8.7
9.2
9.1
9.0
8.8
9.3
9.2
9.0
8.9
11.7
11.5
11.3
11.1
11.9
11.7
11.5
11.3
12.0
11.8
11.6
11.4
12.2
12.0
11.7
11.5
13.4
13.2
13.0
12.7
13.6
13.4
13.2
12.9
13.8
13.6
13.3
13.0
14.0
13.8
13.5
13.2
15.7
15.4
15.2
14.9
15.9
15.7
15.4
15.2
16.0
15.8
15.6
15.3
16.2
16.0
15.8
15.5

82 (27.8)
MBh
kW
56.6
16.6
61.7
18.1
66.7
19.6
71.7
21.0
59.8
17.5
65.3
19.2
70.8
20.8
74.6
21.9
65.9
19.3
72.3
21.2
78.8
23.1
76.6
22.5
68.9
20.2
75.8
22.2
80.2
23.5
77.5
22.7
65.2
19.1
71.0
20.8
76.7
22.5
82.2
24.1
71.3
20.9
78.0
22.9
84.6
24.8
91.1
26.7
76.0
22.3
83.4
24.4
90.7
26.6
93.1
27.3
82.8
24.3
91.2
26.7
98.0
28.7
95.0
27.9
74.1
21.7
80.8
23.7
87.4
25.6
93.9
27.5
80.1
23.5
87.7
25.7
95.1
27.9
99.8
29.2
85.9
25.2
94.3
27.6
102.6
30.1
101.6
29.8
94.6
27.7
104.3
30.6
107.3
31.4
103.8
30.4
86.3
25.3
93.9
27.5
101.5
29.7
108.9
31.9
94.2
27.6
102.9
30.2
111.6
32.7
120.1
35.2
99.2
29.1
108.6
31.8
118.1
34.6
122.8
36.0
108.7
31.8
119.6
35.1
129.8
38.0
125.7
36.8

Sensible Capacity
Entering Air DBT F (C)
80 (26.7)
78 (25.6)
MBh
kW
MBh
kW
51.9
15.2
47.3
13.9
57.0
16.7
52.4
15.3
62.1
18.2
57.4
16.8
67.0
19.6
62.3
18.3
54.6
16.0
49.5
14.5
60.2
17.7
55.1
16.1
65.7
19.3
60.6
17.8
71.1
20.8
66.0
19.3
59.9
17.5
53.8
15.8
66.3
19.4
60.3
17.7
72.7
21.3
66.7
19.6
76.6
22.5
73.0
21.4
62.4
18.3
55.9
16.4
69.3
20.3
62.8
18.4
76.2
22.3
69.7
20.4
77.5
22.7
76.4
22.4
60.1
17.6
55.0
16.1
65.9
19.3
60.7
17.8
71.5
21.0
66.4
19.5
77.1
22.6
72.0
21.1
65.3
19.1
59.3
17.4
72.0
21.1
66.0
19.3
78.6
23.0
72.5
21.3
85.0
24.9
79.0
23.2
69.3
20.3
62.6
18.3
76.7
22.5
69.9
20.5
84.0
24.6
77.2
22.6
91.2
26.7
84.4
24.7
75.0
22.0
67.3
19.7
83.5
24.5
75.7
22.2
91.8
26.9
84.1
24.6
95.0
27.9
92.2
27.0
68.0
19.9
62.0
18.2
74.7
21.9
68.7
20.1
81.3
23.8
75.3
22.1
87.8
25.7
81.8
24.0
73.2
21.4
66.2
19.4
80.7
23.7
73.8
21.6
88.2
25.9
81.3
23.8
95.6
28.0
88.6
26.0
78.1
22.9
70.3
20.6
86.5
25.3
78.7
23.1
94.9
27.8
87.1
25.5
101.6
29.8
95.3
27.9
85.5
25.1
76.4
22.4
95.2
27.9
86.1
25.2
104.8
30.7
95.7
28.1
103.8
30.4
103.8
30.4
79.4
23.3
72.5
21.3
87.1
25.5
80.2
23.5
94.6
27.7
87.7
25.7
102.0
29.9
95.1
27.9
86.2
25.3
78.1
22.9
94.9
27.8
86.9
25.5
103.6
30.4
95.6
28.0
112.1
32.9
104.1
30.5
90.4
26.5
81.7
23.9
99.9
29.3
91.2
26.7
109.4
32.1
100.6
29.5
118.6
34.8
109.8
32.2
98.5
28.9
88.4
25.9
109.5
32.1
99.4
29.1
120.2
35.2
110.1
32.3
125.7
36.8
120.8
35.4

76 (24.4)
MBh
kW
42.6
12.5
47.7
14.0
52.7
15.5
57.7
16.9
44.4
13.0
50.0
14.6
55.4
16.2
60.8
17.8
47.8
14.0
54.3
15.9
60.7
17.8
67.0
19.6
49.5
14.5
56.4
16.5
63.2
18.5
69.9
20.5
49.9
14.6
55.6
16.3
61.3
18.0
66.8
19.6
53.2
15.6
59.9
17.6
66.5
19.5
73.0
21.4
55.9
16.4
63.2
18.5
70.5
20.7
77.7
22.8
59.6
17.5
68.0
19.9
76.3
22.4
84.5
24.8
55.9
16.4
62.6
18.3
69.2
20.3
75.7
22.2
59.3
17.4
66.8
19.6
74.3
21.8
81.7
23.9
62.5
18.3
70.9
20.8
79.3
23.2
87.5
25.6
67.3
19.7
77.1
22.6
86.7
25.4
96.2
28.2
65.7
19.2
73.3
21.5
80.9
23.7
88.3
25.9
70.1
20.6
78.9
23.1
87.6
25.7
96.1
28.2
73.0
21.4
82.4
24.2
91.9
26.9
101.1
29.6
78.3
22.9
89.2
26.2
100.0
29.3
110.6
32.4

These capacities are gross ratings. For net capacity deduct the heat of the supply air blower motor kW x 3.415 = MBH
Refer to the appropriate Blower Performance table for the kW of the supply air blower motor.

Technical Sales Guide : 036 - 2005 (1005)

Page 10

Packaged Air Conditioners


AMBIENT 125F (51.7C)

COOLING PERFORMANCE DATA


125 F ( 51.7 C)
Model
DMS

Air Flow Rate


cfm

l/s

2250

1062

2500

1180

3000

1416

3250

1534

2500

1180

3000

1416

3400

1604

4000

1888

3000

1416

3500

1652

4000

1888

4800

2265

3750

1770

4500

2124

5000

2360

6000

2831

90

100

120

150

Note :

Entering Air
WBT

Total Capacity

F
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63
69
67
65
63

MBh
75.6
73.4
71.1
68.8
76.8
74.6
72.3
69.8
78.8
76.5
74.1
71.6
79.7
77.3
74.9
72.4
90.8
88.5
85.9
83.3
93.3
90.8
88.3
85.5
94.8
92.3
89.7
87.0
96.6
94.1
91.5
88.7
99.7
96.9
94.0
90.9
102.0
99.1
96.1
93.0
103.9
101.0
97.9
94.6
106.2
103.1
100.0
96.7
121.6
118.2
114.7
111.1
125.0
121.5
117.9
114.2
126.8
123.3
119.6
115.8
129.7
126.1
122.3
118.4

C
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2
20.6
19.4
18.3
17.2

kW
22.2
21.5
20.9
20.2
22.5
21.9
21.2
20.5
23.1
22.4
21.7
21.0
23.4
22.7
21.9
21.2
26.6
25.9
25.2
24.4
27.3
26.6
25.9
25.1
27.8
27.1
26.3
25.5
28.3
27.6
26.8
26.0
29.2
28.4
27.5
26.6
29.9
29.1
28.2
27.3
30.5
29.6
28.7
27.7
31.1
30.2
29.3
28.3
35.6
34.7
33.6
32.6
36.6
35.6
34.6
33.5
37.2
36.1
35.1
33.9
38.0
37.0
35.9
34.7

Compressor
Power
Input
kW
9.7
9.6
9.4
9.3
9.8
9.6
9.5
9.3
9.9
9.7
9.6
9.5
9.9
9.8
9.7
9.5
12.6
12.3
12.1
11.9
12.8
12.6
12.3
12.1
13.0
12.7
12.5
12.2
13.2
12.9
12.6
12.4
14.5
14.2
13.9
13.7
14.7
14.4
14.1
13.8
14.9
14.6
14.3
14.0
15.1
14.8
14.5
14.2
16.8
16.5
16.3
16.0
17.0
16.8
16.5
16.2
17.1
16.9
16.6
16.3
17.3
17.1
16.8
16.5

82 (27.8)
MBh
kW
54.7
16.0
59.8
17.5
64.8
19.0
68.8
20.2
57.9
17.0
63.4
18.6
68.9
20.2
69.8
20.5
64.0
18.8
70.4
20.6
74.1
21.7
71.6
21.0
66.9
19.6
73.8
21.6
74.9
21.9
72.4
21.2
62.9
18.4
68.6
20.1
74.3
21.8
79.8
23.4
69.0
20.2
75.6
22.2
82.2
24.1
85.5
25.1
73.7
21.6
81.0
23.7
88.3
25.9
87.0
25.5
80.4
23.6
88.8
26.0
91.5
26.8
88.7
26.0
71.6
21.0
78.2
22.9
84.7
24.8
90.9
26.6
77.6
22.7
85.1
24.9
92.5
27.1
93.0
27.3
83.3
24.4
91.7
26.9
97.9
28.7
94.6
27.7
92.0
27.0
101.7
29.8
100.0
29.3
96.7
28.3
83.7
24.5
91.4
26.8
98.8
29.0
106.2
31.1
91.6
26.8
100.3
29.4
108.9
31.9
114.2
33.5
96.6
28.3
106.0
31.1
115.4
33.8
115.8
33.9
106.0
31.1
116.9
34.3
122.3
35.9
118.4
34.7

Sensible Capacity
Entering Air DBT F (C)
80 (26.7)
78 (25.6)
MBh
kW
MBh
kW
50.1
14.7
45.4
13.3
55.2
16.2
50.5
14.8
60.1
17.6
55.5
16.3
65.1
19.1
60.4
17.7
52.8
15.5
47.6
14.0
58.3
17.1
53.2
15.6
63.8
18.7
58.6
17.2
69.1
20.3
64.0
18.8
58.0
17.0
51.9
15.2
64.4
18.9
58.4
17.1
70.8
20.7
64.8
19.0
71.6
21.0
71.0
20.8
60.5
17.7
54.0
15.8
67.4
19.7
60.9
17.8
74.2
21.7
67.7
19.8
72.4
21.2
72.4
21.2
57.8
16.9
52.7
15.4
63.5
18.6
58.4
17.1
69.2
20.3
64.0
18.8
74.7
21.9
69.6
20.4
63.0
18.5
57.0
16.7
69.6
20.4
63.6
18.6
76.2
22.3
70.1
20.6
82.6
24.2
76.6
22.4
67.0
19.6
60.3
17.7
74.3
21.8
67.6
19.8
81.6
23.9
74.9
21.9
87.0
25.5
82.0
24.0
72.7
21.3
65.0
19.0
81.1
23.8
73.3
21.5
89.3
26.2
81.6
23.9
88.7
26.0
88.7
26.0
65.5
19.2
59.4
17.4
72.1
21.1
66.1
19.4
78.7
23.1
72.6
21.3
85.1
24.9
79.1
23.2
70.6
20.7
63.7
18.7
78.1
22.9
71.2
20.9
85.5
25.1
78.6
23.0
92.9
27.2
85.9
25.2
75.5
22.1
67.8
19.9
83.9
24.6
76.1
22.3
92.2
27.0
84.4
24.7
94.6
27.7
92.5
27.1
82.9
24.3
73.9
21.6
92.6
27.1
83.5
24.5
100.0
29.3
93.1
27.3
96.7
28.3
96.7
28.3
76.9
22.5
70.0
20.5
84.5
24.8
77.6
22.7
91.9
26.9
85.1
24.9
99.3
29.1
92.5
27.1
83.6
24.5
75.6
22.2
92.3
27.0
84.3
24.7
100.9
29.6
92.9
27.2
109.4
32.1
101.4
29.7
87.8
25.7
79.1
23.2
97.3
28.5
88.6
26.0
106.7
31.3
97.9
28.7
115.8
33.9
107.1
31.4
95.9
28.1
85.8
25.1
106.8
31.3
96.7
28.3
117.5
34.4
107.4
31.5
118.4
34.7
118.0
34.6

76 (24.4)
MBh
kW
40.7
11.9
45.8
13.4
50.8
14.9
55.7
16.3
42.5
12.5
48.0
14.1
53.5
15.7
58.9
17.3
45.9
13.5
52.3
15.3
58.7
17.2
65.0
19.0
47.6
13.9
54.4
16.0
61.2
17.9
67.9
19.9
47.6
13.9
53.3
15.6
58.9
17.3
64.4
18.9
50.9
14.9
57.6
16.9
64.1
18.8
70.5
20.7
53.5
15.7
60.9
17.8
68.1
20.0
75.3
22.1
57.2
16.8
65.6
19.2
73.9
21.7
82.0
24.0
53.4
15.6
60.0
17.6
66.5
19.5
73.0
21.4
56.8
16.6
64.2
18.8
71.7
21.0
79.0
23.1
60.0
17.6
68.3
20.0
76.6
22.5
84.7
24.8
64.8
19.0
74.4
21.8
84.0
24.6
93.4
27.4
63.1
18.5
70.7
20.7
78.2
22.9
85.6
25.1
67.6
19.8
76.3
22.4
84.9
24.9
93.4
27.4
70.4
20.6
79.8
23.4
89.2
26.1
98.4
28.8
75.6
22.2
86.5
25.4
97.3
28.5
107.9
31.6

These capacities are gross ratings. For net capacity deduct the heat of the supply air blower motor kW x 3.415 = MBH
Refer to the appropriate Blower Performance table for the kW of the supply air blower motor.

Technical Sales Guide : 036 - 2005 (1005)

Page 11

Technical Sales Guide : 036 - 2005 (1005)

1.5

1.5

2.2

12 / 12

12 / 12

12 / 12

15 / 15

90

100

120

150

3.0

kW

Size

DMS

4.0

3.0

2.2

2.2

kW

Optional

Motor

Standard

Fan

MODEL

FAN PERFORMANCE

2831

6000

2124

4500

2360

1770

3750

5000

2265

4800

1652

3500

1888

1416

3000

4000

1888

4000

1416

3000

1604

1180

2500

3400

1534

3250

1180

2500

1416

1062

2250

3000

l/s

cfm

AIR FLOW
RATE

733

644

618

544

964

835

759

689

845

753

697

637

732

697

637

612

RPM

0.20

784

703

679

615

1008

893

828

772

903

826

780

728

809

780

728

705

RPM

0.40

1.85

1.20

0.94

0.63

1.93

1.22

0.90

0.65

1.24

0.86

0.66

0.46

0.78

0.66

0.46

0.37

KW

(100)

833

757

737

681

1058

956

900

848

967

900

855

807

883

855

807

792

RPM

0.60

2.03

1.33

1.07

0.75

2.07

1.36

1.03

0.76

1.39

0.99

0.77

0.53

0.91

0.77

0.53

0.44

KW

(150)

879

810

792

743

1109

1018

967

918

1029

965

924

885

949

924

885

876

RPM

0.80

2.21

1.47

1.19

0.88

2.23

1.52

1.16

0.85

1.54

1.11

0.86

0.61

1.01

0.86

0.61

0.52

KW

(200)

Areas shaded in grey represent upsize motors

1.66

1.05

0.81

0.53

1.83

1.11

0.79

0.54

1.13

0.75

0.55

0.37

0.67

0.55

0.37

0.30

kW

(50)

924

860

846

805

1162

1079

1028

982

1090

1026

989

962

1011

989

962

958

RPM

1.00

2.37

1.62

1.34

1.02

2.41

1.67

1.28

0.93

1.70

1.22

0.94

0.70

1.11

0.94

0.70

0.62

KW

(250)

966

908

897

864

1215

1135

1084

1047

1144

1083

1053

1036

1071

1053

1036

1036

RPM

1.20

2.53

1.78

1.49

1.16

2.59

1.81

1.38

1.03

1.84

1.31

1.04

0.81

1.20

1.04

0.81

0.73

KW

(300)

1009

955

948

921

1187

1140

1112

1140

1118

1108

1131

1118

1108

1111

RPM

1.40

EXTERNAL STATIC PRESSURE , inwg ( Pa )

2.69

1.95

1.66

1.32

1.94

1.48

1.13

1.41

1.14

0.92

1.30

1.14

0.92

0.84

KW

(350)

1049

1003

997

976

1236

1196

1175

1198

1181

1177

1191

1181

1177

1182

RPM

1.60

2.88

2.12

1.83

1.48

2.05

1.57

1.25

1.51

1.26

1.05

1.41

1.26

1.05

0.96

KW

(400)

1090

1048

1045

1029

1284

1251

1236

1255

1242

1243

1249

1242

1243

1249

RPM

1.80

3.07

2.31

2.01

1.65

2.16

1.69

1.38

1.64

1.39

1.18

1.54

1.39

1.18

1.09

KW

(450)

1129

1093

1092

1082

1333

1307

1297

1311

1303

1307

1307

1303

1307

1315

RPM

2.00

3.27

2.50

2.19

1.83

2.27

1.82

1.51

1.77

1.53

1.31

1.67

1.53

1.31

1.21

KW

(500)

Packaged Air Conditioners

Page 12

Packaged Air Conditioners

DRIVE AND PULLEY DATA


Low Static Drive Set
Pitch Diameter

Model
DMS

Pitch Dia

Motor
Pulley

Bush

Min

Max

Fan Pulley

RPM Range

Bush

mm

Centre
Distance

mm

Min

Max

mm

Belt Size

90

VAR 108 A1

1210 x 24 mm

78

102

SPA-180 1

1610 x 25 mm

180

628

822

490

1404

100

VAR 108 A1

1210 x 24 mm

78

102

SPA-170 1

1610 x 25 mm

170

665

870

490

1388

120

VAR 108 A1

1210 x 28 mm

78

102

SPA-170 1

1610 x 25 mm

170

665

870

490

1388

150

VAR 108 A1

1210 x 28 mm

78

102

SPA-200 1

2012 x 25 mm

200

566

740

495

1446

Centre
Distance

Belt Size

Standard Drive Set


Pitch Diameter

Model
DMS

Pitch Dia

Motor
Pulley

Bush

Min

Max

Fan Pulley

RPM Range

Bush

mm

mm

Min

Max

mm

90

VAR 108 A1

1210 x 24 mm

78

102

SPA-125 1

1610 x 25 mm

125

905

1183

490

1318

100

VAR 108 A1

1210 x 24 mm

78

102

SPA-132 1

1610 x 25 mm

132

857

1120

490

1329

120

VAR 108 A1

1210 x 28 mm

78

102

SPA-132 1

1610 x 25 mm

132

854

1120

490

1329

150

VAR 108 A1

1210 x 28 mm

116

102

SPA-150 1

1610 x 25 mm

150

754

986

495

1367

Centre
Distance

Belt Size

High Static Drive Set


Pitch Diameter

Model
DMS

Pitch Dia

Motor
Pulley

Bush

Min

Max

Fan Pulley

RPM Range

Bush

mm

mm

Min

Max

mm

90

VAR 108 A1

1210 x 24 mm

78

102

SPA-112 1

1610 x 25 mm

112

1010

1321

490

1297

100

VAR 108 A1

1210 x 24 mm

78

102

SPA-106 1

1610 x 25 mm

106

1067

1395

490

1288

120

VAR 108 A1

1210 x 28 mm

78

102

SPA-106 1

1610 x 25 mm

106

1067

1395

490

1288

150

VAR 108 A1

1210 x 28 mm

78

102

SPA-150 1

1610 x 25 mm

118

958

1253

495

1317

ELECTRICAL DATA
380-415 V / 3 Ph / 50 Hz

Power Supply
Model

DMS-090

DMS-100

DMS-120

DMS-150

Compressors

Condenser
Fan Motors

RLA Each

LRA Each

FLA Each

14.6

90.0

2.3

17.4

22.7

11.6

105.0

115.0

80.0

2.3

2.3

4.3

Technical Sales Guide : 036 - 2005 (1005)

Supply Blower Motor


Standard

Extended
FLA

3.6

3.6

4.9

6.6

Electric Heater
kW

4.9

4.9

6.6

8.6

Amperes

Minimum Circuit
Amperes

Maximum Fuse
Breaker Size

Amperes

Amperes

26.3

40

9.0

13.7

26.3

40

18.0

27.3

33.2

50

30.6

40

9.0

13.7

30.6

40

18.0

27.3

33.2

50

39.4

50

9.0

13.7

39.4

50

18.0

27.3

39.4

50

41.0

60

18.0

27.3

41.0

60

36.0

54.7

65.6

90

Page 13

Packaged Air Conditioners

DIMENSIONAL DATA - DMS 090, 100 & 120


Clearances

inches

mm

Front (Compressor Access)

36

914

Back (Blower Fan Access)

36

914

Left (Filter Access)

30

762

Right (Condenser Coil)

36

914

Above (Condenser Air Discharge)

72

1829

Technical Sales Guide : 036 - 2005 (1005)

Page 14

Packaged Air Conditioners

DIMENSIONAL DATA - DMS 150


Clearances

inches

mm

Front (Control Panel & Compressor Access)

36

914

Left (Filter Access)

30

762

Right (Condenser Coil)

36

914

Above (Condenser Air Discharge)

72

1829

Technical Sales Guide : 036 - 2005 (1005)

Page 15

Packaged Air Conditioners

TYPICAL WIRING DIAGRAM : 380 - 415V / 3Ph / 50 Hz

Technical Sales Guide : 036 - 2005 (1005)

Page 16

Packaged Air Conditioners

GUIDE SPECIFICATIONS
DESCRIPTION
Standard Units shall be factory assembled, single packaged,
cool only, designed for outdoor mounted installation. The
7.5, 8.5, 10 and 12.5 ton units shall have minimum EER
ratings of 8.8. They shall have built-in side duct connections
for discharge / supply and return. The units shall be factory
wired, piped, charged with R-22 refrigerant and factory tested
prior to shipment. All unit wiring shall be both numbered
and colour coded.

Coils
a.

Evaporator and condenser coils shall have aluminum


fins mechanically bonded to seamless, internally
enhanced copper tubes with all joints brazed.
Special heresite coating shall be available as a factory
option.

b.

Evaporator and Condenser coils shall be of the direct


expansion, draw-thru, design.
Coils shall be tested up to a pressure of 250 psig
(evaporator) and 450 psig (condenser).

UNIT CABINET
Unit cabinet shall be constructed of G90 galvanized steel,
with exterior surfaces coated with a non chalking, powdered
paint finish, to meet ASTM B 117 standards suitable for
750 hours salt spray test. The indoor blower and air supply
section shall be insulated with 1 thick fibre glass insulation.

Refrigerant Circuit and Refrigerant Safety components


shall include
a.

Thermostatic expansion valve with external equalizing


line.

b.

Filter drier / strainer to eliminate any moisture or foreign


matter.

c.

Accessible service gauge connections on both suction


and discharge lines to charge, evacuate, and measure
refrigerant pressure during any necessary servicing or
troubleshooting, without losing charge.

d.

The refrigeration system shall provide at least 15F of


sub cooling at design conditions.

INDOOR (EVAPORATOR) FAN ASSEMBLY

e.

Fan shall be a belt drive assembly and include an adjustable


pitch motor pulley. Fan wheel shall be double inlet double
width type with forward curved blades, dynamically balanced
to operate smoothly throughout the entire range of operation.
Airflow design shall be constant air volume. Bearings shall
be cartridge type with life long (permanent) lubrication. The
evaporator motor shall be TEFC IP54 class F insulation.

Models with nominal capacities of 7.5, 8.5 and 10 TR,


shall have one refrigerant circuit, while models with
nominal capacities of 12.5 TR shall have dual
independent circuits.

f.

Unit shall operate with conventional thermostat designs


and have a low voltage terminal strip for easy hookup.

g.

Unit control board shall have on board diagnostics and


fault code display.

h.

Standard controls shall include anti short cycle and


low voltage protection, and permit cooling operation
down to 50F.

i.

Control board shall monitor each refrigerant safety


switch independently.

j.

Control board shall retain last 5 fault codes in nonvolatile


memory, which will not be lost in the event of a power
loss.

Cabinet panels shall be easily removable for servicing and


maintenance. Provision shall be provided to assure reliable
transit of equipment, overhead rigging and fork lifting.
Disposable 2" filters shall be furnished and be accessible
through a removable access door, sealed airtight.
Condensate pan shall be internally sloped to comply with
IAQ standards. Condensate connection shall be a minimum
of 1" FPT connection.

OUTDOOR (CONDENSER) FAN ASSEMBLY


Unit shall have one condenser fan / motor. The outdoor fan
shall be of the direct driven propeller type, discharge air
vertically, and shall be dynamically balanced for smooth
operation. The outdoor fan motor shall be totally enclosed
IP54 with class F insulation. The motor shall have
permanently lubricated bearings and shall have external
overload protection.

REFRIGERANT COMPONENTS
Compressors
a.

b.

Compressors for all models shall be hermetic


reciprocating. All compressors shall be internally
protected with internal high pressure relief and over
temperature protection.
Shall be mounted on neoprene mounts to eliminate
vibration from being transmitted to the unit structure
and cabinet.

Technical Sales Guide : 036 - 2005 (1005)

ELECTRIC HEATING - OPTIONAL


(FIELD / FACTORY INSTALLED)
As required by the application, 2 stage control shall be
provided for nickel chromium electric heating elements of
9 or 18 kW capacity (for 7.5, 8.5 & 10 TR models) or, 18 or
36 kW capacity for (12.5 TR models).
Models with the heating section shall have a primary limit
control(s) and automatic reset to prevent the heating element

Page 17

Packaged Air Conditioners


system from operating at an excessive temperature. Units
with Electric Heating shall be wired for a single point power
supply.

temperature. The compressor, with standard controls, shall


be capable of operation down to 50F outdoor temperature.

ELECTRICAL REQUIREMENTS
UNIT OPERATING CHARACTERISTICS
Unit shall be capable of starting and running at 125F outdoor

Technical Sales Guide : 036 - 2005 (1005)

All unit power wiring shall enter unit cabinet at a single


factory provided gland be capable of side entry.

Page 18

Packaged Air Conditioners

MAINTENANCE
The Saber Packaged Air Conditioners are premium quality machines with very low
maintenance requirements.
Compressors used in Saber Packaged Units are of hermetic reciprocating typr and are
charged with the correct amount of refrigerant and lubricating oil. Unless there is a
leak in the system, no topping up is generally required.
All bearings used in the fan shaft, fan motor and evaporator fan motor are permanently
lubricated for life. Lubrication is therefore not a part of the periodic maintenance schedule.

EVERY MONTH
z

Remove the filters and blow compressed air over them to get rid of loose dust.
Visually inspect the filters conditions, replace them with new ones of same sizes
if required.

Saber Packaged Air Conditioners are provided with a specially designed drain
pan, for proper maintenance check and clean blockages at drain connections if
any.

EVERY 3 MONTHS
In addition to the monthly maintenance above, check the belt tension of evaporator
fan. A correct tension is indicated when the belt has a relaxation of approximately 10
mm to 13 mm when pressed lightly with a finger.

EVERY SIX MONTHS


In addition to the maintenance done every three months :
z

The condenser coils should be cleaned by spraying water over it at low pressure or
with a brush while ensuring that the fins are not damaged.

Check all electrical connections and tighten them if required.

Clean all accessible electrical panels of dirt and dust. Before cleaning the control
panels, ENSURE that the electrical power to the unit is switched off.

EVERY 12 MONTHS
In addition to the maintenance done every six months :
z

Use a proper cleaning cloth to clean fan blades and motors.

Ensure that the unit is working properly by checking, current, voltages, pressures
and temperatures.

Check the earthing or grounding of the unit.

Check the exterior of the unit for any signs of corrosion. Even though it is highly
unlikely, if any corrosion that is seen, should be removed by proper sanding the
surface. Repaint the unit with proper touch up paint, available from York.

Check the unit for any unusual vibrations or noise, locate the cause and rectify it
by changing mounts, base isolators etc as required.

Technical Sales Guide : 036 - 2005 (1005)

Page 19

Whenever you need air conditioning, the York name

product choices for residential and light commercial

assures you of the highest standards of design,

applications.

quality and reliability.


Our offering includes package
York is the only independent air

& split air-conditioners and heat

conditioning

pumps. In addition, York offers

focused

manufacturer

solely

on

air

chillers, air-handling units,

conditioning, heating, ventilation

ventilation equipment and

and refrigeration. This gives us

controls for larger projects.

a unique insight into designing


products that match your exact

Our

requirements.

Technology' is leading the way

'Cutting

Edge

in developing efficient and


We're providing solutions for

environment friendly solutions

today's most critical concerns -

for your homes, offices and

energy efficiency, refrigerant

places of leisure.

alternatives and indoor air


quality. York has a wide range of

Let us create the ideal


environment for you.

York products are available from :

You might also like