This past week, Ive been working deploying a vBlock1.

In case you werent aware, the vBlock solutions are basically reference
architectures consisting of EMC storage, Cisco UCS blade servers, and VMware. They come in three different flavors
(vBlock0, vBlock1, and vBlock2) each with different models of SANs and quantity of UCS chassis/blades. Specifically, this
vBlock1 solution being deployed consisted of an EMC CX4-480 array, two UCS blade chassis with eight full width blades, and
obviously VMware, which would be installed on to each blade server.
During design discussions with the client, one thing discussed quite a bit consisted of how to ensure uniqueness of systems
and resources residing in this particular vBlock. Specifically here, Im referring to WWPN/WWNN and MAC Addresses.
The UCS system allows the creation of Pools that will automatically assign WWPN/WWNN and MAC Addresses to servers as
service profiles are applied to them. Just as with any server, we need to ensure these values are unique within the
environment. Because portions of each of these values are adjustable by UCS Administrators, its important to put in a
standard practice for determining what these values are to be. Further, with a standard in place these values can be easily
used by Network and Storage Administrators to determine what type of system is accessing what within their world.
Digging some for best practices surrounding this and through personal experience, the below is how we determined what these
pools would consist of.
First WWPN/WWNN:
The IEEE standard for WWPN/WWNNs dictates a value of eight octets. By default if we look at what UCS Manager
automatically uses well see 20:00:00:25:B5:00:00:00. When creating a pool you would change portions of this value (in
order to make it unique) and then determine how many WWPN/WWNNs you require for your environment. This ultimately
creates a block of WWPN/WWNNs. As service profiles are associated to blade servers, WWPN/WWNNs are derived from this
block and assigned to servers. So how can we ensure UCS clusters are unique within a given environment housing multiple
clusters? Looking at the below helps break out that eight octet value to something we can work with and better understand.

Breaking this all down we can say:

A Denotes this is an IEEE standard format. This means we must leave the value of 2 intact and unchanged.

B:CD Are vendor specific so we can put what we like here. For now, my suggestion is leave B unchanged. More
on the CD values in a minute

EF:GH:IJ These 24 bits are the OUI. This should be the hardware vendor assigned OUI. Because of this, best
practice is to not touch these values.

KL:MN:OP The last 24 bits are fair game to change as needed.

The default UCS entry put in the above picture would look like this:

So how do we come up with a standard unique pattern? As mentioned already, there are certain bits that must remain
untouched so lets look at those we can. The second octet CD, can be utilized to denote the UCS domain (or cluster). If this
is the first UCS cluster in the environment, I suggest making this 01 then increasing the count as new clusters are deployed (i.e.
the second cluster would be 02, third 03, and so on). For the last 24 bits, there are no limits as to what we can use here so
wouldnt it be useful to have something that helped Storage Administrators know what it was checking into their environment.
Some proposed values may look like:

KL = Identifies this as a WWPN or WWNN.


o

FF = Denotes this is a WWNN

0A = Denotes an WWPN on Fabric A

0B = Denotes an WWPN on Fabric B

MN:OP = Sequential numbering handled automatically by UCS Manager

Putting this to practice I created the following for the first UCS cluster:
WWNN Pool = 20:01:00:25:B5:FF:00:01
WWPN Pool Fabric A = 20:01:00:25:B5:0A:00:01
WWPN Pool Fabric B = 20:01:00:25:B5:0B:00:01
Now lets look at the MAC Address Pools. This pool is not as detailed or cryptic as the WWPN/WWNNs so well get through
this quickly.
MAC Addresses are derived from a total of six octets. Like WWPN/WWNNs certain values cannot be changed. Lets break
each octet out again to better understand.

Breaking this down we can say:

AB:CD:EF Like the WWPN/WWNN these first 24 bits are specific to the hardware vendor OUI. We should leave
these set and fortunately, UCS Manager will not allow you to change these.

GH:IJ:KL The last 24 bits can be changed as needed.

The default UCS entry put in the above picture would look like the below:

***UPDATE BEGIN***
I had some great input from a few people (@stevie_chambers, @jonisick, and @jeremywaldrop) on the original post on how
best to handle these pools. Me being an old server guy, I thought being able to tell what OS was running on the blade from its
MAC would be helpful. In addition, the networking gents made a suggestion that including the fabric ID would also be helpful.
Something I very much agree with here as should you start to see MACs from an A fabric running over the B fabric you would
know something is wrong.

With the above in mind, to make MAC addresses unique, Id propose the following breakdown for the last 24 bits:

GH = UCS Domain

IJ = Denote what host OS is to be installed onto the blade along with the specific fabric ID.

0A = VMware Fabric A

1A = Linux Fabric A

2A = Windows Fabric A

3A = Solaris Fabric A

0B = VMware Fabric B

1B = Linux Fabric B

2B = Windows Fabric B

3B = Solaris Fabric B

KL = Sequential number handled automatically by UCS Manager.

Putting this to practice, I created the following pools:


ESX MAC Address Pool Fabric A = 00:25:B5:01:0A:01
ESX MAC Address Pool Fabric B = 00:25:B5:01:0B:01
Windows MAC Address Pool Fabric A = 00:25:B5:01:2A:01
Windows MAC Address Pool Fabric B = 00:25:B5:01:2B:01
***UPDATE ENDS***
Some final thoughts and proposed best practices pertaining to both WWNN/WWPN and MAC Addresses pools would be:

Create WWN pools in block sizes of 16. This is a best practice as you can easily determine which derived
WWPN/WWNN will get assigned to a specific blade.

Match WWPN with WWNN blocks. This ensures when both are assigned to a server profile, they line up with one
another and can be easily distinguished.

Only create block sizes large enough for your environment. Additional blocks can be created as required.

Remember if youre utilizing the Palo card, youll need to figure out how many dynamic NICs are to be allocated to
each server. Each vNIC will have an assigned MAC Address.

Like most things, I dont think there is one way to do this. The above is just something that made sense to me and will ensure
uniqueness across any given environment (big or small).
If you have a scheme you have used in the past, Id love to hear how you handled things