SITRANS P measuring instruments for pressure

Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series

Overview

SITRANS P pressure transmitters, DS III series, are digital pressure transmitters featuring extensive user-friendliness and high
accuracy. Parameterization is performed using input keys or by
means of HART communication.
Extensive functionality enables the pressure transmitter to be
precisely adapted to the plants requirements. Operation is very
simple in spite of the numerous setting options.
Transmitters with type of protection "Intrinsic safety" and "Explosion-proof" may be installed within potentially explosive atmospheres (zone 1) or in zone 0. The transmitters are provided with
an EC type examination certificate and comply with the corresponding harmonized European standards (ATEX).
The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of
highly viscous substances.
Various versions of the DS III pressure transmitters are available
for measuring:
Pressure
Absolute pressure
For differential pressure transmitters
Level
Volume
Volume flow
Mass flow

Benefits
High quality and long life
High reliability even under extreme chemical and mechanical
loads
Extensive diagnosis and simulation functions
Separate replacement of measuring cell and electronics without recalibration
Minimum conformity error
Small long-term drift
Wetted parts made of high-grade materials (e.g. stainless
steel, Hastelloy, gold, Monel, tantalum)
Measuring range 1 mbar ... 400 bar
High measuring accuracy
Parameterization using input keys and HART communication

Application
The pressure transmitters of the DS III series, can be used in industrial areas with extreme chemical and mechanical loads.
Electromagnetic compatibility in the range 10 kHz to 1 GHz
makes the DS III pressure transmitters suitable for locations with
high electromagnetic emissions.
Pressure transmitters with type of protection "Intrinsic safety" and
"Explosion-proof" may be installed within potentially explosive atmospheres (zone 1) or in zone 0. The pressure transmitters are
provided with an EC type examination certificate and comply
with the corresponding harmonized European standards
(ATEX).
Pressure transmitters with the type of protection "Intrinsic safety"
for use in zone 0 may be operated with power supply units of category "ia" and "ib".
The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of
highly viscous substances.
The pressure transmitters can be programmed locally using
three input keys or externally through HART communication.
Pressure transmitters for pressure
Measured variable: Pressure of aggressive and non-aggressive
gases, vapors and liquids.
Nominal measuring ranges: 1 ... 400 bar (14.5 ... 5802 psi)
Pressure transmitters for absolute pressure
Measured variable: Absolute pressure of aggressive and nonaggressive gases, vapors and liquids.
Nominal measuring ranges: 250 mbar ... 100 bar
(3.63 ... 1450 psi)
There are two series:
Pressure series
Differential pressure series
Pressure transmitters for differential pressure and flow
Measured variables:
Differential pressure
Small positive or negative pressure

Siemens FI 01 2005

2/23

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series

Nominal measuring ranges: 20 mbar ... 30 bar (0.29 ... 435 psi)
Pressure transmitters for level
Measured variable: Level of aggressive and non-aggressive liquids in open and closed vessels.
Nominal measuring ranges: 250 mbar ... 5 bar (3.63 ... 72.5 psi)
Nominal diameter of the mounting flange:
DN 80 or DN 100
3 inch or 4 inch

The electrical connections for the power supply and screen are
accessible by unscrewing the rear cover. The bottom part of the
housing contains the measuring cell with process connection
(1). The measuring cell is protected from rotating by a locking
screw (8). As the result of this modular design, the measuring
cell and the electronics can be replaced separately from each
other. The set parameter data are retained.
At the top of the housing is a plastic cover (5), under which the
input keys can be found.

Function
Mode of operation of the electronics

In the case of level measurements in open containers, the lowpressure connection of the measuring cell remains open
(measurement "compared to atmospheric").

0 0 00 0
00

In the case of measurements in closed containers, the lowerpressure connection has to be connected to the container in order to compensate the static pressure.

The wetted parts are constructed from a variety of materials depending on the degree of corrosion resistance required.

10

mC

IA, UH
7

Design

HART interface
EEPROM

Electronics
1

Sensor
Pe
1
2
3
4
5
6
7
8
9
10
IA
UH
Pe

EEPROM

Flow q ~ p (together with a primary differential pressure device)

Measuring cell

Measuring cell sensor


Instrument amplifier
Analog-to-digital converter
Microcontroller
Digital-to-analog converter
One non-volatile memory each in the measuring cell and electronics
HART interface
Three input keys (local operation)
Digital display
Diode circuit and connection for external ammeter
Output current
Power supply
Input variable

Front view

Function diagram of the electronics

The transmitter consists of various components depending on


the order. The possible versions are listed in the ordering information. The components described below are the same for all
transmitters.

The bridge output voltage created by the sensor (1, Figure


"Function diagram of the electronics") is amplified by the instrument amplifier (2) and digitized in the analog-to-digital converter
(3). The digital information is evaluated in a microcontroller, its linearity and temperature response corrected, and converted in a
digital-to-analog converter (5) into an output current of 4 to
20 mA.

The rating plate (3, Figure "Front view") with the Order No. is located on the side of the housing. The specified number together
with the ordering information provide details on the optional design details and on the possible measuring range (physical properties of built-in sensor element).
The approval label is located on the opposite side.
The housing is made of die-cast aluminium or stainless steel precision casting. A round cover is screwed on at the front and rear
of the housing. The front cover (6) can be fitted with a viewing
pane so that the measured values can be read directly on the digital display. The inlet (4) for the electrical connection is located
either on the left or right side. The unused opening on the opposite side is sealed by a blanking plug. The protective earth connection is located on the rear of the housing.

2/24

Siemens FI 01 2005

The diode circuit (10) protects against incorrect polarity.


The data specific to the measuring cell, the electronics data, and
the parameter data are stored in the two non-volatile memories
(6). The one memory is coupled to the measuring cell, the other
to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from
each other.
Using the 3 input keys (8) you can parameterize the pressure
transmitter directly at the point of measurement. The input keys
can also be used to control the view of the results, the error messages and the operating modes on the digital display (9).

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series
The HART modem (7) permits parameterization using a protocol
according to the HART specification.

Measuring cell for absolute pressure from differential pressure


series

The pressure transmitters with spans 63 bar measure the input


pressure compared to atmosphere, transmitters with spans
160 bar compared to vacuum.
2

Mode of operation of the measuring cells

Measuring cell for pressure


5
pe

6
5
4

1
2
3
4
5
pe

Measuring cell
Process connection
Seal diaphragm
Filling liquid
Silicon pressure sensor
Pressure as input variable

2
p

Measuring cell for pressure, functional diagram

The pressure pe is applied through the process connection (2,


Figure "Measuring cell for pressure, functional diagram) to the
measuring cell (1). This pressure is subsequently transmitted
further through the seal diaphragm (3) and the filling liquid (4) to
the silicon pressure sensor (5) whose measuring diaphragm is
then flexed. The resistance of the four piezo-resistors fitted in the
diaphragm in a bridge circuit thus changes. This change in resistance results in a bridge output voltage proportional to the input pressure.

1
2
3
4
5
6
7
8
pe

Reference vacuum
Overload diaphragm
Silicon pressure sensor
O-ring
Process flange
Seal diaphragm
Body of measuring cell
Filling liquid
Absolute pressure as
input variable

Measuring cell for absolute pressure from differential pressure series,


functional diagram

The input pressure pe is transmitted through the seal diaphragm


(6, Figure "Measuring cell for absolute pressure from differential
pressure series, functional diagram") and the filling liquid (8) to
the silicon pressure sensor (3).
The difference in pressure between the input pressure pe and
the reference vacuum (1) on the low-pressure side of the measuring cell flexes the measuring diaphragm. The resistance of the
four piezo-resistors fitted in the diaphragm in a bridge circuit
thus changes. This change in resistance results in a bridge output voltage proportional to the absolute pressure.
An overload diaphragm is installed to provide protection from
overloads. If the measuring limits are exceeded, the overload diaphragm (2) is flexed until the seal diaphragm rests on the body
of the measuring cell (7), thus protecting the silicon pressure
sensor from overloads.
Measuring cell for differential pressure and flow

Measuring cell for absolute pressure from pressure series


2

3
1

pe

1
2
3
4
5
pe

Measuring cell
Process connection
Seal diaphragm
Filling liquid
Silicon absolute pressure sensor
Absolute pressure as input variable

Measuring cell for absolute pressure from the pressure series, functional
diagram

The absolute pressure pe is transmitted through the seal diaphragm (3, Figure "Measuring cell for absolute pressure from
pressure series, functional diagram") and the filling liquid (4) to
the silicon absolute pressure sensor (5) whose measuring diaphragm is then flexed. The resistance of the four piezo-resistors
fitted in the diaphragm in a bridge circuit thus changes. This
change in resistance results in a bridge output voltage proportional to the input pressure.

1
5

1
2
3
4
5
6
7

Seal diaphragm
O-ring
Overload diaphragm
Silicon pressure sensor
Process flange
Body of measuring cell
Filling liquid

Measuring cell for differential pressure and flow, functional diagram

The differential pressure is transmitted through the seal diaphragms (1, Figure "Measuring cell for differential pressure and
flow, functional diagram") and the filling liquid (7) to the silicon
pressure sensor (4).
The measuring diaphragm is flexed by the applied differential
pressure. The resistance of the four piezo-resistors fitted in the
diaphragm in a bridge circuit thus changes. This change in resistance results in a bridge output voltage proportional to the absolute pressure.
An overload diaphragm is installed to provide protection from
overloads. If the measuring limits are exceeded, the overload diaphragm (2) is flexed until the seal diaphragm rests on the body
of the measuring cell (7), thus protecting the silicon pressure
sensor from overloads.

Siemens FI 01 2005

2/25

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series

Measuring cell for level

8
+

10

1
2
3
4
5

The following diagnostics functions are available using HART


communication:
Zero correction display
Event counter
Limit transmitter
Saturation alarm
Slave pointer
Simulation functions
Maintenance timer
Parameterization using the input keys (local operation)

Flange with tube


Seal diaphragm on
mounting flange
Seal diaphragm
Body of measuring cell
Overload diaphragm

6
7
8
9
10

Silicon pressure sensor


O-ring
Process flange
Filling liquid
Capillary with filling liquid
of mounting flange

With the input keys you can easily set the most important parameters without any additional equipment.
Parameterization using HART communication
Parameterization using HART communication is performed with
a HART communicator or a PC.
+

Measuring cell for level, functional diagram

The input pressure (hydrostatic pressure) acts hydraulically on


the measuring cell through the seal diaphragm on the mounting
flange (2, Figure "Measuring cell for level, functional diagram").
This differential pressure is subsequently transmitted further through the measuring cell (3) and the filling liquid (9) to the silicon
pressure sensor (6) whose measuring diaphragm is then flexed.
The resistance of the four piezo-resistors fitted in the diaphragm
in a bridge circuit thus changes.
This change in resistance results in a bridge output voltage proportional to the differential pressure.
An overload diaphragm is installed to provide protection from
overloads. If the measuring limits are exceeded, the overload diaphragm (2) is flexed until the seal diaphragm rests on the body
of the measuring cell (7), thus protecting the silicon pressure
sensor from overloads.

230 ... 1100 W

SITRANS P
transmitter

Power supply

HART
communicator

HART communication between a HART communicator and a pressure


transmitter

When parameterizing with the HART communicator, the connection is made directly to the 2-wire system.

230 ... 500 W

SITRANS P
transmitter

Parameterization

PC or
laptop

HART
modem

Depending on the version, there are different possibilities for parameterizing the pressure transmitter and for setting or scanning
the parameters.

Power supply

RS 232

Adjustable parameters
Parameters

Input keys

HART communication

Start of scale

Full-scale value

Electrical damping

Start-of-scale value without application of a x


pressure ("Blind setting")

End-of-scale value without application of a x


pressure ("Blind setting")

Zero adjustment

HART communication between a PC communicator and a pressure


transmitter

When parameterizing with a PC, the connection is made through


a HART modem.
The signals needed for communication in conformity with the
HART 5.x or 6.x protocols are superimposed on the output current using the Frequency Shift Keying (FSK) method.
Physical dimensions available for the display
Physical variable

Physical dimensions

Pressure (setting can also


be made in the factory)

Pa, MPa, kPa, hPa, bar, mbar, torr, atm,


psi, g/cm2, kg/cm2, inH20, inH20 (4 C),
mmH20, ftH20, inHg, mmHg

Current transmitter

Fault current

Level (height data)

m, cm, mm, ft, in

Disabling of keys, write protection

x 1)

Volume

Type of dimension and actual dimension

m3, dm3, hl, yd3, ft3, in3, US gallon, lmp,


gallon, bushel, barrel, barrel liquid

Characteristic (linear / square-rooted)

x 2)

x 2)

Volume flow

m3/d, m3/h, m3/s, l/min, l/s, ft3/d, ft3/min,


ft3/s, US gallon/min, US gallon/s

Mass flow

t/d, t/h, t/min, kg/d, kg/h, kg/min, kg/s, g/d,


g/h, g/min, g/s, lb/d, lb/h, lb/min, lb/s,
LTon/d, LTon/h, STon/d, STon/h, STon/min

Total mass flow

t, kg, g, lb, oz, LTon, STon

Input of characteristic

Freely-programmable LCD

Diagnostics functions

1)

Cancel apart from write protection


2)
Only differential pressure

2/26

Siemens FI 01 2005

Temperature

K, C, F, R

Miscellaneous

%, mA

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for pressure

Technical specifications

Process connection

SITRANS P pressure transmitters, DS III series, for pressure


Input
Measured variable

Pressure

Span (continuously adjustable)

Maximum working pressure

Power supply UH

0.01 ... 1 bar (0.145 ... 14.5 psi)

6 bar (87 psi)

Terminal voltage on transmitter

0.04 ... 4 bar (0.58 ... 58 psi)

10 bar (145 psi)

0.16 ... 16 bar (2.32 ... 232 psi)

32 bar (464 psi)

Certificates and approvals

0.6 ... 63 bar (9.14 ... 914 psi)

100 bar (1450 psi)

Classification according to pressure


equipment directive
(DRGL 97/23/EC)

1.6 ... 160 bar (23.2 ... 2320 psi)

250 bar (3626 psi)

4.0 ... 400 bar (58 ... 5802 psi)

500 bar (7252 psi)

Lower measuring limit


Measuring cell with silicone oil filling

30 mark (0.435 psi) absolute

Upper measuring limit

100% of max. span (max. 160 bar


(2320 psi) with oxygen measurement and inert liquid)

Intrinsic safety "i"


- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +70 C (-40 ... +158 F)
temperature class T5;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To certified intrinsically-safe circuits with maximum values:


Ui = 30 V, Ii = 100 mA,
Pi = 750 mW; Ri = 300

- Effective internal inductance/capacitance

Li = 0.4 mH, Ci = 6 nF

Explosion-proof "d"

Error in measurement and fixedpoint setting (including hysteresis


and repeatability)
Linear characteristic
- r 10

(0.0029 r +0.071)%

- 10 < r 30

(0.0045 r +0.071)%

- 30 < r 100

(0.005 r +0.05)%

Influence of ambient temperature


With -10 ... +60 C (14 ... 140 F)

(0.08 r +0.1)%

With -40 ... -10 C and


+60 C ... +85 C
(-40 ... +14 and 140 ... 185 F)

(0.1 r +0.15)% / 10 K
( (0.1 r +0.15)% / 18 F)

Rated conditions
Degree of protection (to EN 60529)

IP65

Process temperature
Measuring cell with silicone oil filling

-40 ... +100 C (-40 ... +212 F)

Measuring cell with inert filling liquid

-20 ... +100 C (-4 ... +212 F)

In conjunction with dust explosion


protection

-20 ... +60 C (-4 ... +140 F)

Design
Weight (without options)

1.5 kg ( 3.3 lb)

PTB 99 ATEX 1160

- Identification

Ex II 1/2 G EEx d IIC T4/T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To circuits with values:


UH = 10.5 ... 45 V DC

Dust explosion protection for zone


20

PTB 01 ATEX 2055

- Identification

Ex II 1 D IP65 T 120C
Ex II 1/2 D IP65 T 120 C

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)

- Max.surface temperature

120 C (248 F)

- Connection

To certified intrinsically-safe circuits with maximum values:


Ui = 30 V, Ii = 100 mA,
Pi = 750 mW, Ri = 300

- Effective internal inductance/capacitance

Li = 0.4 mH, Ci = 6 nF

Dust explosion protection for zone


21/22

PTB 01 ATEX 2055

- Identification

Ex II 2 D IP65 T 120 C

- Connection

To circuits with values:


UH = 10.5 ... 45 V DC;
Pmax = 1.2 W

Wetted parts materials


Stainless steel, mat. No.
1.4404/316L or Hastelloy C4, mat.
No. 2.4610

Type of protection "n" (zone 2)

Seal diaphragm

Stainless steel, mat. No.


1.4404/316L or Hastelloy C276,
mat. No. 2.4819

Explosion protection to FM

Measuring cell filling

Silicone oil or inert filling liquid


(max. 160 bar (2320 psi) with oxygen measurement)

Connection shank

PTB 99 ATEX 2122


Ex II 1/2 G EEx ia/ib IIB/IIC T6

4 ... 20 mA
Increasing characteristic
Start-of-scale value 0 bar
Stainless steel seal diaphragm
Silicone oil filling
Room temperature (25 C (77 C))
r: Span ratio (r = max. span / set
span)

For gases of fluid group 1 and


liquids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)

- Identification

Measuring accuracy
Reference conditions

10.5 ... 45 V DC
10.5 ... 30 V DC in intrinsicallysafe mode

Explosion protection

Output
Output signal

Connection shank GA to DIN


EN 837-1, female thread -14
NPT or oval flange (PN 160
(MWP 2320)) with mounting
thread M10 or 7/16-20 UNF to EN
61518

- Identification

- Identification (XP/DIP) or (IS);


(NI)

TV 01 ATEX 1696 X
Ex II 3 G EEx nA L IIC T4/T5/T6
Certificate of Compliance
3008490
CL I, DIV 1, GP ABCD T4...T6;
CL II, DIV 1, GP EFG; CL III; CL I,
ZN 0/1 AEx ia IIC T4...T6; CL I,
DIV 2, GP ABCD T4...T6; CL II,
DIV 2, GP FG; CL III

Siemens FI 01 2005

2/27

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for pressure
Explosion protection to CSA

Certificate of Compliance
1153651

- Identification (XP/DIP) or (IS)

CL I, DIV 1, GP ABCD T4...T6;


CL II, DIV 1, GP EFG; CL III; Ex ia
IIC T4...T6; CL I, DIV 2, GP ABCD
T4...T6; CL II, DIV 2, GP FG; CL III

Dimensional drawings
55
(0.6)

1)

120 (4.7)

72 (2.8)

36,5
(1,44)

117 (4.6)
1)

100 (3.94)

ca. 96 (3.78)

28
(1.1)

68 (2.7)

4)

50
(1.97)

50
(1.97)

69
(2.7)

ca. 30 (1.2)

123 (4.8)
min. 77 (3.0) 5)

7
105 (4.1)

2
3

4
5
6
7
8

Process connection:
- -14 NPT,
- connection shank GA or
- oval flange
Blanking plug
Electrical connection:
- screwed gland Pg 13,5 (adapter)2) 3),
- screwed gland M20x1,5 3),
- screwed gland -14 NPT or
- Han 7D/ Han 8U plug 2) 3)
Terminal side
Electronics side, digital display (longer overall
length for cover with window)
Protective cover over keys
Mounting bracket (option)
Screw cover - safety bracket (only for type of protection
"Explosion-proof enclosure", not shown in the drawing)

1)
2)
3)
4)
5)

Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing


Not with type of protection "explosion-proof enclosure"
Not with type of protection "FM + CSA [is + xp]"
45 mm (1.8 inch) for Pg 13,5 with adapter
Minimum distance for rotation

SITRANS P pressure transmitters, DS III series for pressure, dimensional drawing, dimensions in mm (inch)

2/28

Siemens FI 01 2005

171 (6.7)
237 (9.3)

138 (5.4)

20
(0.8)

15
(0.6)

80
(3.15)

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for pressure
Order No.

Selection and Ordering data

SITRANS P pressure transmitter, DS III series, } 7 M F 4 0 3 3 for pressure


77777 - 7777
2-wire system
Measuring cell filling
Silicone oil
Inert liquid1)

Measuring cell
cleaning
Standard
Grease-free

} 1
3

Measured span
0.01 ... 1 bar
0.04 ... 4 bar
0.16 ... 16 bar
0.63 ... 63 bar
1.6 ... 160 bar
4.0 ... 400 bar

(0.15 ... 14.5 psi)


(0.58 ... 58 psi)
(2.32 ... 232 psi)
(9.14 ... 914 psi)
(23.2 ... 2320 psi)
(58.0 ... 5802 psi)

}
}
}
}
}
}

1)
2)
3)
4)

For oxygen application, add Order code E10.


Without cable gland, with blanking plug
With enclosed cable gland EEx ia and blanking plug
Not together with type of protection "Explosion-proof"

B
C
D
E
F
G

Wetted parts materials


Seal diaphragm
Process connection
Stainless steel
Stainless steel
Hastelloy
Stainless steel
Hastelloy
Hastelloy
Version as diaphragm seal
Process connection
Connection shank GB to EN 837-1
Female thread -14 NPT
Oval flange made of stainless steel,
max. span 160 bar (2320 psi)
- Mounting thread 7/16-20 UNF to
EN 61518
- Mounting thread M10 to DIN 19213
Non-wetted parts materials
Housing made of die-cast aluminium
Housing stainless steel precision casting

A
B
C
Y0

0
1

2
3
}

Design
Standard design
International version, English label inscriptions, }
documentation in 5 languages on CD
Explosion protection
without
with ATEX, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 2)
- "Intrinsic safety and explosion-proof enclosure }
(EEx ia + EEx d)" 3)
- "n (zone 2)"
- "Intrinsic safety, explosion-proof enclosure and
dust explosion protection (EEx ia + EEx d +
zone 1D/2D)" 3)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 2)
Electrical connection / cable inlet
Screwed gland Pg 13.5 (adapter) 4)
Screwed gland M20x1.5
Screwed gland -14 NPT
Han 7D plug (plastic housing) incl. mating
connector 4)
Display
without (digital indicator hidden, setting: mA)

with visible digital indicator, setting: mA


with customer-specific digital indicator (setting
as specified, Order code "Y21" or "Y22" required)

0
3
1
2

A
B
D
P
E
R

NC
A
B
C
D

1
6
7

} Available ex stock
Power supply units see "SITRANS I power supply units and input isolators".
Included in delivery of the device:
Brief instructions (Leporello)
CD-ROM with detailed documentation

Siemens FI 01 2005

2/29

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for pressure

Further designs

Order code

Additional data

Order code

Please add "-Z" to Order No. and specify Order code.

Please add "-Z" to Order No. and specify Order code.

Pressure transmitter with mounting bracket made of:


Steel
A01
Stainless steel
A02

Measuring range to be set


specify in plain text:
Y01: ... to ... mbar, bar, kPa, MPa, psi

Y01

Plug
Han 7D (metal, gray)
Han 8U (instead of Han 7D)

Measuring point number/identification


max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Entry of HART address (TAG)


max. 8 characters, specify in plain text:
Y17: ...........................................

Y17

Setting of pressure indicator in pressure units


specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C

Y21

Setting of pressure indicator in non-pressure units


specify in plain text:
Y22: ..... up to ..... l/min, m3/h, m, USgpm, ...
(specification of measuring range in pressure units
"Y01" is essential, unit with max. 5 characters)

Y22 + Y01

Rating plate inscription


(instead of German)
English
French
Spanish
Italian

A30
A31

B11
B12
B13
B14

English rating plate


Pressure units in inH2O or psi

B21

Manufacturer's test certificate M


(calibration certificate)
to DIN 55350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10204-3.1.B

C12

Factory certificate
to EN 10204-2.2

C14

Certificate "Functional Safety (SIL)"

C20

Setting of upper limit of output signal to 22.0 mA

D05

Acid gas version to NACE


(only together with seal diaphragm made of Hastelloy)

D07

Type of protection IP68


(not together with Han 7D / Han 8U plug,
Pg 13.5 screwed gland)

D12

Digital indicator along side the input keys


(only together with the devices 7MF4033-....0-.A.6
or -.A.7-Z, Y21 or Y22 + Y01)

D27

Use in or at zone 1D/2D


(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

Oxygen application
(max. 160 bar (2320 psi) with oxygen measurement
and inert liquid)

E10

2/30

Siemens FI 01 2005

Only the settings for "Y01", "Y21", "Y22" and "D05" can be made in the
factory
Ordering example
Item line:
7MF4033-1EA00-1AA7-Z
B line:
A01 + Y01 + Y21
C line:
Y01: 10 ... 20 bar (145 ... 290 psi)
C line:
Y21: bar (psi)

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for absolute pressure
(from pressure series)

Technical specifications

Process connection

SITRANS P pressure transmitters, DS III series for absolute pressure, from the pressure series
Input
Measured variable

Absolute pressure

Power supply UH

Span

Maximum working pressure

8.3 ... 250 mbar (0.12 ... 3.6 psi)

6 bar (87 psi)

Terminal voltage on pressure transmitter

43 ... 1300 mbar (0.62 ... 18.9 psi)

10 bar (145 psi)

160 ... 5000 mbar


(2.32 ... 72.5 psi)

30 bar (435 psi)

1 ... 30 bar (14.5 ... 435 psi)

100 bar (1450 psi)

Classification according to pressure


equipment directive
(DRGL 97/23/EC)

Measuring cell with silicone oil filling

0 mark (0 psi) absolute

Explosion protection

Upper measuring limit

100% of max. span (max. 160 bar


(2320 psi) with oxygen measurement and inert liquid)

Output signal

Intrinsic safety "i"

Error in measurement and fixedpoint setting (including hysteresis


and repeatability)

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +70 C (-40 ... +158 F)
temperature class T5;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To certified intrinsically-safe circuits with maximum values:


Ui = 30 V, Ii = 100 mA,
Pi = 750 mW; Ri = 300

- Effective internal inductance/capacitance

Li = 0.4 mH, Ci = 6 nF

Explosion-proof "d"

Linear characteristic
- r 10

(0.0029 r +0.071)%

- 10 < r 30

(0.0045 r +0.071)%

Influence of ambient temperature


With -10 ... +60 C (14 ... 140 F)

(0.1 r +0.2)%

With -40 ... -10 C and


+60 C ... +85 C
(-40 ... +14 and 140 ... 185 F)

(0.1 r +0.15)% / 10 K
( (0.1 r +0.15)% / 18 F)

IP65

Process temperature
Measuring cell with silicone oil filling

-40 ... +100 C (-40 ... +212 F)

Measuring cell with inert filling liquid

-20 ... +100 C (-4 ... +212 F)

In conjunction with dust explosion


protection

-20 ... +60 C (-4 ... +140 F)

Design
Weight (without options)

1.5 kg ( 3.3 lb)

Wetted parts materials


Connection shank

Stainless steel, mat. No.


1.4404/316L or Hastelloy C4, mat.
No. 2.4610

Seal diaphragm

Stainless steel, mat. No.


1.4404/316L or Hastelloy C276,
mat. No. 2.4819

Measuring cell filling

Silicone oil or inert filling liquid


(max. 160 bar (2320 psi) with oxygen measurement)

PTB 99 ATEX 1160

- Identification

Ex II 1/2 G EEx d IIC T4/T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To circuits with values:


UH = 10.5 ... 45 V DC

Dust explosion protection for


zone 20

PTB 01 ATEX 2055

- Identification

Ex II 1 D IP65 T 120 C
Ex II 1/2 D IP65 T 120 C

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)

- Max.surface temperature

120 C (248 F)

- Connection

To certified intrinsically-safe circuits with maximum values:


Ui = 30 V, Ii = 100 mA,
Pi = 750 mW, Ri = 300

- Effective internal inductance/capacitance

Li = 0.4 mH, Ci = 6 nF

Rated conditions
Degree of protection (to EN 60529)

PTB 99 ATEX 2122


Ex II 1/2 G EEx ia/ib IIB/IIC T6

4 ... 20 mA
Increasing characteristic
Start-of-scale value 0 bar
Stainless steel seal diaphragm
Silicone oil filling
Room temperature (25 C (77 F))
r: Span ratio
(r = max. span / set span)

For gases of fluid group 1 and


liquids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)

- Identification

Measuring accuracy
Reference conditions

10.5 ... 45 V DC
10.5 ... 30 V DC in intrinsicallysafe mode

Certificates and approvals

Lower measuring limit

Output

Connection shank GA to DIN


EN 837-1, female thread -14
NPT or oval flange (PN 160
(MWP 2320)) with mounting
thread M10 or 7/16-20 UNF to
EN 61518

Dust explosion protection for zone


21/22

PTB 01 ATEX 2055

- Identification

Ex II 2 D IP65 T 120 C

- Connection

To circuits with values:


UH = 10.5 ... 45 V DC;
Pmax = 1.2 W

Type of protection "n" (zone 2)


- Identification
Explosion protection to FM
- Identification (XP/DIP) or (IS);
(NI)

TV 01 ATEX 1696 X
Ex II 3 G EEx nA L IIC T4/T5/T6
Certificate of Compliance
3008490
CL I, DIV 1, GP ABCD T4...T6;
CL II, DIV 1, GP EFG; CL III; CL I,
ZN 0/1 AEx ia IIC T4...T6; CL I,
DIV 2, GP ABCD T4...T6; CL II,
DIV 2, GP FG; CL III

Siemens FI 01 2005

2/31

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for absolute pressure
(from pressure series)
Explosion protection to CSA

Certificate of Compliance
1153651

- Identification (XP/DIP) or (IS)

CL I, DIV 1, GP ABCD T4...T6;


CL II, DIV 1, GP EFG; CL III; Ex ia
IIC T4...T6; CL I, DIV 2, GP ABCD
T4...T6; CL II, DIV 2, GP FG; CL III

Dimensional drawings
55
(0.6)

1)

120 (4.7)

72 (2.8)

36,5
(1,44)

117 (4.6)
1)

100 (3.94)

ca. 96 (3.78)

28
(1.1)

68 (2.7)

4)

50
(1.97)

50
(1.97)

69
(2.7)

ca. 30 (1.2)

171 (6.7)
237 (9.3)

138 (5.4)

20
(0.8)

15
(0.6)

80
(3.15)

123 (4.8)
min. 77 (3.0) 5)

7
105 (4.1)

2
3

4
5
6
7
8

Process connection:
- -14 NPT,
- connection shank GA or
- oval flange
Blanking plug
Electrical connection:
- screwed gland Pg 13,5 (adapter)2) 3),
- screwed gland M20x1,5 3),
- screwed gland -14 NPT or
- Han 7D/ Han 8U plug 2) 3)
Terminal side
Electronics side, digital display (longer overall
length for cover with window)
Protective cover over keys
Mounting bracket (option)
Screw cover - safety bracket (only for type of protection
"Explosion-proof enclosure", not shown in the drawing)

1)
2)
3)
4)
5)

Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing


Not with type of protection "explosion-proof enclosure"
Not with type of protection "FM + CSA [is + xp]"
45 mm (1.8 inch) for Pg 13,5 with adapter
Minimum distance for rotation

SITRANS P pressure transmitters, DS III series for absolute pressure, from the pressure series, dimensional drawing, dimensions in mm (inch)

2/32

Siemens FI 01 2005

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for absolute pressure
(from pressure series)
4) Not together with type of protection "Explosion-proof"
E) Combinations of the versions marked with E) are subject to the export regulations AL: 2B230, ECCN: N.

Selection and Ordering data

Order No.

SITRANS P pressure transmitters, DS III series


for absolute pressure from the pressure series

7MF 4 2 3 3 -

2-wire system

77777 - 7777

Measuring cell filling


Silicone oil
Inert liquid

Measuring cell
cleaning
Standard
Grease-free

Measured span
8.3 ... 250 mbar
43 ... 1300 mbar
0.16 ... 5 bar
1 ... 30 bar

(0.12 ... 3.63 psi)


(0.62 ... 18.9 psi)
(2.32 ... 72.5 psi)
(14.5 ... 435 psi)

1
3
E)
E)
E)

D
F
G
H

Wetted parts materials


Seal diaphragm
Process connection
Stainless steel
Stainless steel
Hastelloy
Stainless steel
Hastelloy
Hastelloy
Version for diaphragm seal 1)

E)
E)

Process connection
Connection shank GB to EN 837-1
Female thread -14 NPT
Oval flange made of stainless steel,
max. span 160 bar (2320 psi)
- Mounting thread 7/16-20 UNF to
EN 61518
- Mounting thread M10 to DIN 19213
Non-wetted parts materials
Housing made of die-cast aluminium
Housing stainless steel precision casting
Design
Standard design
International version, English label inscriptions,
documentation in 5 languages on CD

A
B
C
Y0
0
1

2
3
0
3
1
2

Explosion protection
without
with ATEX, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 2)
- "Intrinsic safety and explosion-proof enclosure
(EEx ia + EEx d)" 3)
- "n (zone 2)"
- "Intrinsic safety, explosion-proof enclosure and
dust explosion protection (EEx ia + EEx d +
zone 1D/2D)" 3)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 2)
Electrical connection / cable inlet
Screwed gland Pg 13.5 4)
Screwed gland M20x1.5
Screwed gland -14 NPT
Han 7D plug (plastic housing) incl. mating
connector 4)
Display
without (digital indicator hidden, setting: mA)
with visible digital indicator
with customer-specific digital indicator (setting
as specified, Order code "Y21" required)

A
B
D
P
E
R

NC
A
B
C
D

1
6
7

Power supply units see "SITRANS I power supply units and input isolators".
The device is delivered together with brief instructions (Leporello) and
a CD-ROM containing detailed documentation.
1) Version 7MF4233-1DY... only up to max. span 200 mbar (2.9 psi)
2) Without cable gland, with blanking plug
3) With enclosed cable gland EEx ia and blanking plug

Siemens FI 01 2005

2/33

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for absolute pressure
(from pressure series)

Further designs

Order code

Further designs

Please add "-Z" to Order No. and specify Order code.

Please add "-Z" to Order No. and specify Order code.

Pressure transmitter with mounting bracket made of:


Steel
A01
Stainless steel
A02

Additional data

Plug
Han 7D (metal, gray)
Han 8U (instead of Han 7D)

A30
A31

Rating plate inscription


(instead of German)
English
French
Spanish
Italian

B11
B12
B13
B14

English rating plate


Pressure units in inH2O or psi

B21

Manufacturer's test certificate M


(calibration certificate)
to DIN 55350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10204-3.1.B

C12

Factory certificate
to EN 10204-2.2

C14

Certificate "Functional Safety (SIL)"

C20

Setting of upper limit of output signal to 22.0 mA

D05

Acid gas version to NACE


(only together with seal diaphragm made of Hastelloy)

D07

Type of protection IP68


(not together with Han 7D / Han 8U plug,
Pg 13.5 screwed gland)

D12

Digital indicator along side the input keys


(only together with the devices 7MF4233-....0-.A.6
or -.A.7-Z, Y21 or Y22 + Y01).

D27

Use in or at zone 1D/2D


(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

Oxygen application
(max. 160 bar (2320 psi) with oxygen measurement
and inert liquid)

E10

2/34

Siemens FI 01 2005

Order code

Measuring range to be set


specify in plain text:
Y01: ... to ... mbar, bar, kPa, MPa, psi

Y01

Measuring point number/identification


max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Entry of HART address (TAG)


max. 8 characters, specify in plain text:
Y17: ...........................................

Y17

Setting of pressure indicator in pressure units


specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C

Y21

Setting of pressure indicator in non-pressure units


specify in plain text:
Y22: ..... up to ..... l/min, m3/h, m, USgpm, ...
(specification of measuring range in pressure units
"Y01" is essential, unit with max. 5 characters)

Y22 + Y01

Only the settings for "Y01", "Y21", "Y22" and "D05" can be made in the
factory

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for absolute pressure
(from differential pressure series)

Technical specifications
SITRANS P pressure transmitters, DS III series for absolute pressure, from the differential pressure series

Measuring cell filling

Silicone oil or inert filling liquid


(max. 160 bar (2320 psi) with oxygen measurement)

Process connection

Female thread -18 NPT and


flange connection to DIN 19 213
with mounting thread M10 or
7/ -20 UNF
16

Input
Measured variable

Absolute pressure

Span

Maximum working pressure

Power supply UH

8.3 ... 250 mbar (0.12 ... 3.6 psi)

32 bar (464 psi)

43 ... 1300 mbar (0.62 ... 18.9 psi)

32 bar (464 psi)

Terminal voltage on pressure transmitter

160 ... 5000 mbar


(2.32 ... 72.5 psi)

32 bar (464 psi)

1 ... 30 bar (14.5 ... 435 psi)

160 bar (2320 psi)

5.3 ... 100 bar (76.9 ... 1450 psi)

160 bar (2320 psi)


With connection thread M10 and
7/ -20 UNF in the process flan16
ges

Lower measuring limit


0 mark (0 psi) absolute

Upper measuring limit

100% of max. span (max. 160 bar


(2320 psi) with oxygen measurement and inert liquid)

Start of scale

Continuously adjustable between


the measuring limits

Output
Output signal

Certificates and approvals


Classification according to pressure
equipment directive
(DRGL 97/23/EC)

Ex II 1/2 G EEx ia/ib IIB/IIC T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +70 C (-40 ... +158 F)
temperature class T5;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To certified intrinsically-safe circuits with maximum values:


Ui = 30 V, Ii = 100 mA,
Pi = 750 mW; Ri = 300

- Effective internal inductance/capacitance

Li = 0.4 mH, Ci = 6 nF

4 ... 20 mA
Increasing characteristic
Start-of-scale value 0 bar
Stainless steel seal diaphragm
Silicone oil filling
Room temperature (25 C (77 F))
r: Span ratio
(r = max. span / set span)

Error in measurement and fixedpoint setting (including hysteresis


and repeatability)

Explosion-proof "d"

(0.0029 r + 0.071)%

- 10 < r 30

(0.0045 r + 0.071)%

Ex II 1/2 G EEx d IIC T4/T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To circuits with values:


UH = 10.5 ... 45 V DC

Dust explosion protection for zone


20

(0.1 r +0.2)%
Twice the value with 20-mbar
(0.29 psi) measuring cell

With -40 ... -10 C and


+60 C ... +85 C
(-40 ... +14 and 140 ... 185 F)

(0.1 r +0.15)% / 10 K
( (0.1 r +0.15)% / 18 F)
Twice the value with 20-mbar
(0.29 psi) measuring cell

Rated conditions
Degree of protection (to EN 60529)

IP65

Process temperature
Measuring cell with silicone oil filling

-40 ... +100 C (-40 ... +212 F)

Measuring cell with inert filling liquid

-20 ... +100 C (-4 ... +212 F)

In conjunction with dust explosion


protection

-20 ... +60 C (-4 ... +140 F)

Ex II 1 D IP65 T 120 C
Ex II 1/2 D IP65 T 120 C

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)

- Max.surface temperature

120 C (248 F)

- Connection

To certified intrinsically-safe circuits with maximum values:


Ui = 30 V, Ii = 100 mA,
Pi = 750 mW, Ri = 300

- Effective internal inductance/capacitance

Li = 0.4 mH, Ci = 6 nF

Weight (without options)

Dust explosion protection for


zone 21/22

Ex II 2 D IP65 T 120 C

- Connection

To circuits with values:


UH = 10.5 ... 45 V DC;
Pmax = 1.2 W

- Identification
4.5 kg ( 9.9 lb)

Explosion protection to FM

Wetted parts materials


Seal diaphragm

Stainless steel, mat. No.


1.4404/316L, Hastelloy C276,
mat. No. 2.4819, Monel, mat. No.
2.4360, tantalum or gold

PTB 01 ATEX 2055

- Identification

Type of protection "n" (zone 2)

Design

PTB 01 ATEX 2055

- Identification

Influence of ambient temperature


With -10 ... +60 C (14 ... 140 F)

PTB 99 ATEX 1160

- Identification

Linear characteristic
- r 10

PTB 99 ATEX 2122

- Identification

Measuring accuracy
Reference conditions

For gases of fluid group 1 and


liquids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)

Explosion protection
Intrinsic safety "i"

Measuring cell with silicone oil filling

10.5 ... 45 V DC
10.5 ... 30 V DC in intrinsicallysafe mode

- Identification (XP/DIP) or (IS);


(NI)

TV 01 ATEX 1696 X
Ex II 3 G EEx nA L IIC T4/T5/T6
Certificate of Compliance
3008490
CL I, DIV 1, GP ABCD T4...T6;
CL II, DIV 1, GP EFG; CL III; CL I,
ZN 0/1 AEx ia IIC T4...T6; CL I,
DIV 2, GP ABCD T4...T6; CL II,
DIV 2, GP FG; CL III
Siemens FI 01 2005

2/35

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for absolute pressure
(from differential pressure series)
Explosion protection to CSA

Certificate of Compliance
1153651

- Identification (XP/DIP) or (IS)

CL I, DIV 1, GP ABCD T4...T6;


CL II, DIV 1, GP EFG; CL III; Ex ia
IIC T4...T6; CL I, DIV 2, GP ABCD
T4...T6; CL II, DIV 2, GP FG; CL III

Dimensional drawings

3
approx. 261 (10.3)

198 (7.8)

1
+

Space for rotation


of housing

10
8

7
11

ca. 96 (3.78)

52 (2.05)

96 (3.8)

117 (4.6)

80
(3.15)

1)

69 (2.7)
77 (3) 4)

5 1)

100 (3.94)

approx. 30 (1.2) 5)

50
(1.97)
50
(1.97)

138 (5.4)

20
(0.8)

15
(0.6)

134 (5.27)

3
72 (2.83)
105 (4.1)
1
2
3

4
5
6
7
8
9
10
11

Process connection: -18 NPT (EN 61518)


Blanking plug
Electrical connection:
- screwed gland Pg 13,5 (adapter) 2) 3),
- screwed gland M20x1,5 3),
- screwed gland -14 NPT or
- Han 7D/ Han 8U plug 2) 3)
Terminal side
Electronics side, digital display (longer overall length for cover with window)
Protective cover over keys
Mounting bracket (option)
Sealing screw with valve (option)
Screw cover - safety bracket (only for type of protection
"Explosion-proof enclosure", not shown in the drawing)
Lateral venting for liquid measurement
Lateral venting for gas measurement (suffix H02)

68 (2.7)
120 (4.7)

1)
2)
3)
4)
5)

Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing


Not with type of protection "explosion-proof enclosure"
Not with type of protection "FM + CSA [is + xp]"
92 mm (3.62 inch) for minimum distance to permit rotation with indicator
45 mm (1.8 inch) for Pg 13,5 with adapter

SITRANS P pressure transmitters, DS III series for absolute pressure, from the differential pressure series, dimensional drawing, dimensions in mm
(inch)

2/36

Siemens FI 01 2005

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for absolute pressure
(from differential pressure series)

Selection and Ordering data

Order No.

Selection and Ordering data

Order No.

SITRANS P pressure transmitters, DS III series


for absolute pressure from the series
Differential pressure

7MF 4 3 3 3 -

SITRANS P pressure transmitters, DS III series


for absolute pressure from the series
Differential pressure

7MF 4 3 3 3 -

2-wire system

77777 - 7777

2-wire system

77777 - 7777

Measuring cell filling


Silicone oil
Inert liquid1)

Measuring cell
cleaning
Standard
Grease-free

Measured span
8.3 ... 250 mbar
43 ... 1300 mbar
0.16 ... 5 bar
1 ... 30 bar
5.3 ... 100 bar

(0.12 ... 3.63 psi)


(0.62 ... 18.9 psi)
(2.32 ... 72.5 psi)
(14.5 ... 435 psi)
(76.9 ... 1450 psi)

Display
without (digital indicator hidden, setting: mA)
with visible digital indicator
with customer-specific digital indicator (setting
as specified, Order code "Y21" required)

1
3
E)
E)
E)

D
F
G
H
KE

Power supply units see "SITRANS I power supply units and input isolators".
Included in delivery of the device:
Brief instructions (Leporello)
CD-ROM with detailed documentation
Sealing plug(s) or sealing screw(s) for the process flanges(s)

Wetted parts materials


Seal diaphragm
Parts of measuring cell
Stainless steel
Stainless steel
Hastelloy
Stainless steel
Hastelloy
Hastelloy
Tantalum
Tantalum
Monel
Monel
Gold
Gold
Version for diaphragm seal 2)

E)
E)
E)

Process connection
Female thread -18 NPT with flange connection
Sealing screw opposite process connection
- Mounting thread M10 to DIN 19213
- Mounting thread 7/16-20 UNF to EN 61518
Vent on side of process flange 3)
- Mounting thread M10 to DIN 19213
- Mounting thread 7/16-20 UNF to EN 61518

1
6
7

1)
2)
3)
4)
5)
6)
E)

A
B
C
E
H
L
Y

For oxygen applications, add Order code E10.


Version 7MF4433-1DY... only up to max. span 200 mbar (2.9 psi)
Not for span "5.3 ... 100 bar (76.9 ... 1450 psi)"
Without cable gland, with blanking plug
With enclosed cable gland EEx ia and blanking plug
Not together with type of protection "Explosion-proof"
Combinations of the versions marked with E) are subject to the export
regulations AL: 2B230, ECCN: N.

0
2
4
6

Non-wetted parts materials


Process flange screws Electronics housing
Stainless steel
Stainless steel

Die-cast aluminium
Stainless steel precision
casting

Design
Standard design
International version, English label inscriptions,
documentation in 5 languages on CD
Explosion protection
without
with ATEX, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 4)
- "Intrinsic safety and explosion-proof enclosure
(EEx ia + EEx d)" 5)
- "n (zone 2)"
- "Intrinsic safety, explosion-proof enclosure and
dust explosion protection (EEx ia + EEx d +
zone 1D/2D)" 5)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 4)
Electrical connection / cable inlet
Screwed gland Pg 13.5 6)
Screwed gland M20x1.5
Screwed gland -14 NPT
Han 7D plug (plastic housing) incl. mating
connector 6)

2
3

1
2

A
B
D
P
E
R

NC
A
B
C
D

Siemens FI 01 2005

2/37

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for absolute pressure
(from differential pressure series)

Further designs

Order code

Further designs

Please add "-Z" to Order No. and specify Order code.

Please add "-Z" to Order No. and specify Order code.

Pressure transmitter with mounting bracket made of:


Steel
A01
Stainless steel
A02

Additional data
Measuring range to be set
specify in plain text:
Y01: ... up to ... mbar, bar, kPa, MPa, psi

Y01

Measuring point number/identification


max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Y17

A40

Entry of HART address (TAG)


max. 27 characters, specify in plain text:
Y17: ...........................................

Y21

B11
B12
B13
B14

Setting of pressure indicator in pressure units


specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C
Setting of pressure indicator in non-pressure units
specify in plain text:
Y22: ..... up to ..... l/min, m3/h, m, USgpm, ...
(specification of measuring range in pressure units
"Y01" is essential, unit with max. 5 characters)

Y22 + Y01

O-rings for process flanges


(instead of FPM (Viton))
PTFE (Teflon)
FEP (with silicone core, approved for food)
FFPM (Kalrez, compound 4079)
NBR (Buna N)

A20
A21
A22
A23

Plug
Han 7D (metal, gray)
Han 8U (instead of Han 7D)

A30
A31

Sealing screws
-18 NPT, with valve in material of process flanges
Rating plate inscription
(instead of German)
English
French
Spanish
Italian
English rating plate
Pressure units in inH2O or psi

B21

Manufacturer's test certificate M


(calibration certificate)
to DIN 55350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10204-3.1.B

C12

Factory certificate
to EN 10204-2.2

C14

Certificate "Functional Safety (SIL)"

C20

Setting of upper limit of output signal to 22.0 mA

D05

Acid gas version to NACE


(only together with seal diaphragm made of Hastelloy)

D07

Type of protection IP68


(not together with Han 7D / Han 8U plug,
Pg 13.5 screwed gland)

D12

Digital indicator along side the input keys


(only together with the devices 7MF4333-....0-.A6 or
-.A.7-Z, Y21 or Y22 + Y01)

D27

Use in or at zone 1D/2D


(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

Oxygen application
(max. 160 bar (2320 psi) with oxygen measurement
and inert liquid)

E10

Interchanging of process connection side

H01

Vent on side for gas measurements

H02

Process flange
Hastelloy
Monel
Stainless steel with PVDF insert
max. PN 10 (MWP 145 psi),
Max. temperature of medium 90 C (194 F)

K01
K02
K04

2/38

Siemens FI 01 2005

Order code

Only the settings for "Y01", "Y21", "Y22" and "D05" can be made in the
factory

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow

Technical specifications

Influence of ambient temperature

SITRANS P pressure transmitters, DS III series, for differential pressure and flow
Input
Measured variable

Differential pressure and flow

Span

Maximum working pressure

PN 32 (MWP 464 psi)

With -10 ... +60 C (14 ... 140 F)

(0.08 r +0.1)%

With -40 ... -10 C and


+60 C ... +85 C
(-40 ... +14 and 140 ... 185 F)

(0.1 r +0.15)% / 10 K
( (0.1 r +0.15)% / 18 F)
Twice the value with 20-mbar
(0.29 psi) measuring cell.

Rated conditions
Degree of protection (to EN 60529)

- 1 ... 20 mbar (0.0145 ... 0.29 psi) 32 bar (464 psi)


PN 160 (MWP 2320 psi)

IP65

Process temperature
Measuring cell with silicone oil filling

-40 ... +100 C (-40 ... +212 F)

- 1 ... 60 mbar (0.0145 ... 0.87 psi) 160 bar (2320 psi)
- 2.5 ... 250 mbar
(0.036 ... 3.63 psi)

160 bar (2320 psi)

Measuring cell with inert filling liquid

-20 ... +100 C (-4 ... +212 F)

- 6 ... 600 mbar (0.087 ... 8.7 psi)

160 bar (2320 psi)

In conjunction with dust explosion


protection

-20 ... +60 C (-4 ... +140 F)

- 16 ... 1600 mbar


(0.232 ... 23.2 psi)

160 bar (2320 psi)

- 50 ... 5000 mbar


(0.725 ... 72.5 psi)

160 bar (2320 psi)

- 0.3 ... 30 bar (4.35 ... 435 psi)

160 bar (2320 psi)

Design
Weight (without options)
Seal diaphragm

Stainless steel, mat. No.


1.4404/316L, Hastelloy C276,
mat. No. 2.4819, Monel, mat. No.
2.4360, tantalum or gold

Measuring cell filling

Silicone oil or inert filling liquid


(max. 160 bar (2320 psi) with oxygen measurement)

Process connection

Female thread -18 NPT and


flange connection to DIN 19 213
with mounting thread M10 or
7/ -20 UNF to EN 61518
16

PN 420 (MWP 6092)


- 2.5 ... 250 mbar
(0.036 ... 3.63 psi)

420 bar (6092 psi)

- 6 ... 600 mbar (0.087 ... 8.7 psi)

420 bar (6092 psi)

- 16 ... 1600 mbar


(0.232 ... 23.3 psi)

420 bar (6092 psi)

- 50 ... 5000 mbar


(0.725 ... 72.5 psi)

420 bar (6092 psi)

- 0.3 ... 30 bar (4.35 ... 435 psi)

420 bar (6092 psi)

Lower measuring limit


Measuring cell with silicone oil filling

Upper measuring limit

-100% of max. span


(-33% with 30 bar (435 psi)
measuring cell) or
30 mbar (0.44 psi) absolute
100% of max. span (max. 160 bar
(2320 psi) with oxygen measurement and inert liquid)

Output
Output signal

Power supply UH
Terminal voltage on pressure transmitter

Classification according to pressure


equipment directive
(DRGL 97/23/EC)
PN 32/160 (MWP 464/2320)

For gases of fluid group 1 and


liquids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)

PN 420 (MWP 6092)

For gases of fluid group 1 and


liquids of fluid group 1; complies
with basic safety requirements of
article 3, paragraph 1 (appendix
1); assigned to category III, conformity evaluation module H by
the TV Nord

4 ... 20 mA
Increasing characteristic
Start-of-scale value 0 bar
Stainless steel seal diaphragm
Silicone oil filling
Room temperature (25 C (77 F))
r: Span ratio
(r = max. span / set span)

Error in measurement and fixedpoint setting (including hysteresis


and repeatability)

10.5 ... 45 V DC
10.5 ... 30 V DC in intrinsicallysafe mode

Certificates and approvals

Measuring accuracy
Reference conditions

4.5 kg ( 9.9 lb)

Wetted parts materials

Explosion protection
Intrinsic safety "i"

Linear characteristic
- r 10

(0.0029 r + 0.071)%

- 10 < r 30

(0.0045 r + 0.071)%

- 30 < r 100

(0.005 r +0.05)%

Square-root characteristic (flow


> 50%)
- r 10

0.1%

- 10 < r 30

0.2%

Square-root characteristic (flow


25 ... 50%)
- r 10

0.2%

- 10 < r 30

0.4%

PTB 99 ATEX 2122

- Identification

Ex II 1/2 G EEx ia/ib IIB/IIC T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +70 C (-40 ... +158 F)
temperature class T5;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To certified intrinsically-safe circuits with maximum values:


Ui = 30 V, Ii = 100 mA,
Pi = 750 mW; Ri = 300

- Effective internal inductance/capacitance

L i = 0.4 mH, Ci = 6 nF

Siemens FI 01 2005

2/39

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow

Explosion-proof "d"

PTB 99 ATEX 1160

- Identification

Ex II 1/2 G EEx d IIC T4/T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To circuits with values:


UH = 10.5 ... 45 V DC

Dust explosion protection for


zone 20

PTB 01 ATEX 2055

- Identification

Ex II 1 D IP65 T 120 C
Ex II 1/2 D IP65 T 120 C

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)

- Max.surface temperature

120 C (248 F)

- Connection

To certified intrinsically-safe circuits with maximum values:


Ui = 30 V, Ii = 100 mA,
Pi = 750 mW, Ri = 300

- Effective internal inductance/capacitance

Li = 0.4 mH, Ci = 6 nF

Dust explosion protection for zone


21/22

PTB 01 ATEX 2055

- Identification

Ex II 2 D IP65 T 120 C

- Connection

To circuits with values:


UH = 10.5 ... 45 V DC;
Pmax = 1.2 W

Type of protection "n" (zone 2)


- Identification
Explosion protection to FM
- Identification (XP/DIP) or (IS);
(NI)

Explosion protection to CSA


- Identification (XP/DIP) or (IS)

2/40

Siemens FI 01 2005

TV 01 ATEX 1696 X
Ex II 3 G EEx nA L IIC T4/T5/T6
Certificate of Compliance
3008490
CL I, DIV 1, GP ABCD T4...T6;
CL II, DIV 1, GP EFG; CL III; CL I,
ZN 0/1 AEx ia IIC T4...T6; CL I,
DIV 2, GP ABCD T4...T6; CL II,
DIV 2, GP FG; CL III
Certificate of Compliance
1153651
CL I, DIV 1, GP ABCD T4...T6;
CL II, DIV 1, GP EFG; CL III; Ex ia
IIC T4...T6; CL I, DIV 2, GP ABCD
T4...T6; CL II, DIV 2, GP FG; CL III

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow

Dimensional drawings

3
approx. 261 (10.3)

198 (7.8)

134 (5.27)

1
+

Space for rotation


of housing

10
8

7
11

ca. 96 (3.78)

52 (2.05)

96 (3.8)

1)

69 (2.7)
77 (3) 4)

117 (4.6)

80
(3.15)
5

1)

100 (3.94)

approx. 30 (1.2) 5)

50
(1.97)
50
(1.97)

138 (5.4)

20
(0.8)

15
(0.6)

3
72 (2.83)
105 (4.1)
1
2
3

4
5
6
7
8
9
10
11

Process connection: -18 NPT (EN 61518)


Blanking plug
Electrical connection:
- screwed gland Pg 13,5 (adapter) 2) 3),
- screwed gland M20x1,5 3),
- screwed gland -14 NPT or
- Han 7D/ Han 8U plug 2) 3)
Terminal side
Electronics side, digital display (longer overall length for cover with window)
Protective cover over keys
Mounting bracket (option)
Sealing screw with valve (option)
Screw cover - safety bracket (only for type of protection
"Explosion-proof enclosure", not shown in the drawing)
Lateral venting for liquid measurement
Lateral venting for gas measurement (suffix H02)

68 (2.7)
120 (4.7)

1)
2)
3)
4)
5)

Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing


Not with type of protection "explosion-proof enclosure"
Not with type of protection "FM + CSA [is + xp]"
92 mm (3.62 inch) for minimum distance to permit rotation with indicator
45 mm (1.8 inch) for Pg 13,5 with adapter

SITRANS P pressure transmitters, DS III series for differential pressure and flow, dimensional drawing, dimensions in mm (inch)

Siemens FI 01 2005

2/41

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow

138 (5.4)

80
(3.15)

4 1)

77 (3)4)

4
5
6
7
8
9

Process connection: -18 NPT (EN 61518)


Blanking plug
Electrical connection:
- screwed gland Pg 13,5 (adapter) 2) 3),
- screwed gland M20x1,5 3),
- screwed gland -14 NPT or
- Han 7D/ Han 8U plug 2) 3)
Terminal side
Electronics side, digital display (longer overall length for cover with window)
Protective cover over keys
Mounting bracket (option)
Sealing screw with valve (option)
Screw cover - safety bracket (only for type of protection
"Explosion-proof enclosure", not shown in the drawing)

8
1

ca. 84,6 (3.33)

67 (2.64)5)

1
2
3

100 (3.94)

ca. 85 (3.35)6)

5 1)

approx. 30 (1.18)8)

50
(1.97)

69 (2.7)

ca. 96 (3.78)
20
(0.8)

50
(1.97)

approx. 217 (8.54)7)

15
(0.6)

Space for rotation


of housing

1)
2)
3)
4)
5)
6)
7)
8)

Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing


Not with type of protection "explosion-proof enclosure"
Not with type of protection "FM + CSA [is + xp]"
92 mm (3.6 inch) for minimum distance to permit rotation with indicator
74 mm (2.9 inch) for PN 420 (MWP 6092 psi)
91 mm (3.6 inch) for PN 420 (MWP 6092 psi)
219 mm (8.62 inch) for PN 420 (MWP 6092 psi)
45 mm (1.8 inch) for Pg 13,5 with adapter

SITRANS P pressure transmitters, DS III series for differential pressure and flow, with process covers for vertical differential pressure lines, dimensional
drawing, dimensions in mm (inch)

SITRANS P pressure transmitters, DS III series for differential pressure


and flow, with process covers for vertical differential pressure lines

2/42

Siemens FI 01 2005

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow
4

115 (4.5)

183 (7.2)

77
(3.0)

193 (7.6)

FIELD
TERMINALS
3

1
2
3
4
5
6
7
8

Process connection, -18 NPT (EN 61 518)


Terminal side, analog indicator (optional)
External digital indicator (optional)
Sealing plug
Fixing screw
Blanking plug
Protective cover for keys
Electrical connection

SITRANS P pressure transmitters, DS III series for differential pressure and flow, with digital indicator beside control keys, dimensional drawing, dimensions in mm (inch)

SITRANS P pressure transmitters, DS III series for differential pressure


and flow, with digital indicator beside control keys

Siemens FI 01 2005

2/43

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow

Order No.

Selection and Ordering data

Selection and Ordering data

Order No.

} 7MF 4 4 3 3 SITRANS P pressure transmitters,


DS III series for differential pressure and flow
77777 - 7777
PN 32/160 (MWP 464/2320 psi)

} 7MF 4 4 3 3 SITRANS P pressure transmitters,


DS III series for differential pressure and flow
77777 - 7777
PN 32/160 (MWP 464/2320 psi)

2-wire system

2-wire system

Measuring cell filling


Silicone oil
Inert liquid1)

Measuring cell
cleaning
standard
grease-free

Display
without (digital indicator hidden, setting: mA) }
with visible digital indicator
with customer-specific digital indicator (setting
as specified, Order code "Y21" required)

} 1
3

Measured span
PN 32 (MWP 464 psi)
1 ... 20 mbar 2)

(0.0145 ... 0.29 psi)

PN 160 (MWP 2320 psi)


1 ... 60 mbar
2.5 ... 250 mbar
6 ... 600 mbar
16 ... 1600 mbar
50 ... 5000 mbar
0.3 ... 30 bar

Power supply units see "SITRANS I power supply units and input isolators".

(0.0145 ... 0.87 psi)


(0.036 ... 3.63 psi)
(0.087 ... 8.70 psi)
(0.232 ... 23.2 psi)
(0.725 ... 72.5 psi)
(4.35 ... 435 psi)

}
}
}
}
}
}

C
D
E
F
G
H

Included in delivery of the device:


Brief instructions (Leporello)
CD-ROM with detailed documentation
Sealing plug(s) or sealing screw(s) for the process flanges(s)

} Available ex stock

1) For oxygen application, add Order code E10.


2) Not suitable for connection of remote seal
3) Only together with max. spans 250, 1600, 5000 and 30000 mbar
(3.63, 23.2, 72.5 and 435 psi).
4) Without cable gland, with blanking plug
5) With enclosed cable gland EEx ia and blanking plug
6) Not together with type of protection "Explosion-proof"

Wetted parts materials


(stainless steel process flanges)
Seal diaphragm
Parts of measuring cell
Stainless steel
Stainless steel
Hastelloy
Stainless steel
Hastelloy
Hastelloy
Tantalum 3)
Tantalum
Monel 3)
Monel
Gold 3)
Gold
Version for diaphragm seal

Process connection
Female thread -18 NPT with flange connection
Sealing screw opposite process connection
- Mounting thread M10 to DIN 19213
}
- Mounting thread 7/16-20 UNF to EN 61518
Vent on side of process flange 2)
- Mounting thread M10 to DIN 19213
- Mounting thread 7/16-20 UNF to EN 61518

A
B
C
E
H
L
Y

0
2
4
6

Non-wetted parts materials


Process flange screws Electronics housing
Stainless steel
Stainless steel

Die-cast aluminium
}
Stainless steel precision
casting

Design
Standard design
International version, English label inscriptions, }
documentation in 5 languages on CD
Explosion protection
without
with ATEX, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 4)
- "Intrinsic safety and explosion-proof enclosure }
(EEx ia + EEx d)" 5)
- "n (zone 2)"
- "Intrinsic safety, explosion-proof enclosure and
dust explosion protection (EEx ia + EEx d +
zone 1D/2D)" 5)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 4)
Electrical connection / cable inlet
Screwed gland Pg 13.5 6)
Screwed gland M20x1.5
Screwed gland -14 NPT
Han 7D plug (plastic housing) incl. mating
connector 6)

2/44

1
6
7

Siemens FI 01 2005

2
3

1
2

A
B
D
P
E
R

NC
A
B
C
D

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow
Further designs

Order code

Order code

Further designs

Please add "-Z" to Order No. and specify Order code.

Please add "-Z" to Order No. and specify Order code.

Pressure transmitter with mounting bracket made of:


Steel
A01
Stainless steel
A02

Oxygen application
(max. 160 bar (2320 psi) with oxygen measurement
and inert liquid)

E10

O-rings for process flanges


(instead of FPM (Viton))
PTFE (Teflon)
FEP (with silicone core, approved for food)
FFPM (Kalrez, compound 4079)
NBR (Buna N)

Interchanging of process connection side

H01

Vent on side for gas measurements

H02

A20
A21
A22
A23

Stainless steel process flanges for vertical


differential pressure lines
(not together with K01, K02 and K04) 1)

H03

Plug
Han 7D (metal, gray)
Han 8U (instead of Han 7D)

A30
A31

Sealing screws
-18 NPT, with valve in material of process flanges

A40

Rating plate inscription


(instead of German)
English
French
Spanish
Italian

B11
B12
B13
B14

Process flange
Hastelloy
Monel
Stainless steel with PVDF insert
Max. PN 10 (MWP 145 psi)
Max. temperature of medium 90 C (194 F)

K01
K02
K04

Additional data

English rating plate (calibration certificate)


Pressure units in inH2O or psi

B21

Manufacturer's test certificate M


to DIN 55.350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10 204-3.1.B

C12

Factory certificate
to EN 10.204-2.2

C14

Certificate "Functional Safety (SIL)"

C20

Setting of upper limit of output signal to 22.0 mA

D05

Acid gas version to NACE


(only together with seal diaphragm made of Hastelloy)

D07

Type of protection IP68


(not together with Han 7D / Han 8U plug,
Pg 13.5 screwed gland)

D12

Digital indicator along side the input keys


(only together with the devices 7MF4433-....0-.A.6 or
-.A.7-Z, Y21 or Y22 + Y01)

D27

Use in or at zone 1D/2D


(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

TV approval to AD/TRD

E06

Overfilling safety device for flammable and


non-flammable liquids
(max. PN 32 (MVWP 464 psi), basic device with type of
protection "Intrinsic safety (EEx ia)", to WHG and VbF)

E08

Measuring range to be set


specify in plain text:
with linear characteristic:
Y01: ... up to ... mbar, bar, kPa, MPa, psi
with square-root characteristic:
Y01: ... up to ... mbar, bar, kPa, MPa, psi

Y01
Y02

Measuring point number/identification


max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Entry of HART address (TAG)


max. 27 characters, specify in plain text:
Y17: ...........................................

Y17

Setting of pressure indicator in pressure units


specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C

Y21

Setting of pressure indicator in non-pressure units


specify in plain text:
Y22: ..... up to ..... l/min, m3/h, m, USgpm, ...
(specification of measuring range in pressure units
"Y01" or "Y02" is essential, unit with max. 5 characters)

Y22 2)+
Y01 or Y02

Only the settings for "Y01", "Y21", "Y21", "Y22" and "D05"can be made in
the factory
1) Not suitable for connection of remote seal
2) Not together with over-filling safety device for flammable and
non-flammable liquids (Order code "E08")

Siemens FI 01 2005

2/45

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow

Selection and Ordering data

Order No.

Selection and Ordering data

Order No.

SITRANS P pressure transmitters, DS III series


for differential pressure and flow
PN 420 (MWP 6092 psi)
2-wire system

7MF 4 5 3 3 -

SITRANS P pressure transmitters, DS III series


for differential pressure and flow
PN 420 (MWP 6092 psi)
2-wire system

77777 - 7777

Measuring cell filling


Silicone oil

Measuring cell cleaning


Standard

Measured span
2.5 ... 250 mbar
6 ... 600 mbar
16 ... 1600 mbar
50 ... 5000 mbar
0.3 ... 30 bar

(0.036 ... 3.63 psi)


(0.087 ... 8.70 psi)
(0.232 ... 23.2 psi)
(0.725 ... 72.5 psi)
(4.35 ... 435 psi)

77777 - 7777

Display
without (digital indicator hidden, setting: mA)
with visible digital indicator
with customer-specific digital indicator (setting
as specified, Order code "Y21" required)

1
D
E
F
G
H

Stainless steel
Stainless steel
Gold

Process connection
Female thread -18 NPT with flange connection
Sealing screw opposite process connection
- Mounting thread M12 to DIN 19213
- Mounting thread 7/16-20 UNF to
EN 61518
Vent on side of process flanges
- Mounting thread M12 to DIN 19213
- Mounting thread 7/16-20 UNF to
EN 61518

Scope of delivery: Pressure transmitter as ordered (Instruction Manual is


extra ordering item)
1)
2)
3)
4)

A
B
L

1
3

5
7

Non-wetted parts materials


Process flange screws Electronics housing
Stainless steel
Stainless steel

Die-cast aluminium
Stainless steel precision
casting

Design
Standard design
International version, English label inscriptions,
documentation in 5 languages on CD
Explosion protection
without
with ATEX, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 2)
- "Intrinsic safety and explosion-proof enclosure
(EEx ia + EEx d)" 3)
- "n (zone 2)"
- "Intrinsic safety, explosion-proof enclosure and
dust explosion protection (EEx ia + EEx d +
zone 1D/2D)" 3)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 2),
max. PN 360
Electrical connection / cable inlet
Screwed gland Pg 13.5 4)
Screwed gland M20x1.5
Screwed gland -14 NPT
Han 7D plug (plastic housing) incl. mating
connector 4)

2/46

Siemens FI 01 2005

1
6
7

Power supply units see "SITRANS I power supply units and input isolators".

Wetted parts materials


(stainless steel process flanges)
Seal diaphragm
Parts of measuring cell
Stainless steel
Hastelloy
Gold 1)

7MF 4 5 3 3 -

2
3

1
2

A
B
D
P
E
R

NC

A
B
C
D

Not together with max. span 600 mbar


Without cable gland, with blanking plug
With enclosed cable gland EEx ia and blanking plug
Not together with type of protection "Explosion-proof"

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for differential pressure and flow
Further designs

Order code

Order code

Further designs

Please add "-Z" to Order No. and specify


Order code.

Please add "-Z" to Order No. and specify


Order code.

Pressure transmitter with mounting bracket made of:


Steel
A01
Stainless steel
A02

Additional data

O-rings for process flanges


(instead of FPM (Viton))
PTFE (Teflon)
FEP (with silicone core, approved for food)
FFPM (Kalrez, compound 4079)
NBR (Buna N)

A20
A21
A22
A23

Plug
Han 7D (metal, gray)
Han 8U (instead of Han 7D)

A30
A31

Sealing screws
-18 NPT, with valve in material of process flanges
Rating plate inscription
(instead of German)
English
French
Spanish
Italian

A40

B11
B12
B13
B14

English rating plate


Pressure units in inH2O or psi

B21

Manufacturer's test certificate M


(calibration certificate)
to DIN 55350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10204-3.1.B

C12

Factory certificate
to EN 10204-2.2

C14

Certificate "Functional Safety (SIL)"

C20

Setting of upper limit of output signal to


22.0 mA

D05

Acid gas version to NACE


(only together with seal diaphragm made of Hastelloy)

D07

Type of protection IP68


(not together with Han 7D / Han 8U plug,
Pg 13.5 screwed gland)

D12

Digital indicator along side the input keys


(only together with the devices 7MF4533-....2-.A.6 or
-.A.7-Z, Y21 or Y22 + Y01)

D27

Use in or at zone 1D/2D


(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

Interchanging of process connection side

H01

Stainless steel process flanges for vertical


differential pressure lines

H03

Measuring range to be set


specify in plain text:
with linear characteristic:
Y01: ... up to ... mbar, bar, kPa, MPa, psi
with square-root characteristic:
Y01: ... up to ... mbar, bar, kPa, MPa, psi

Y01
Y02

Measuring point number/identification


max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Entry of HART address (TAG)


max. 27 characters, specify in plain text:
Y17: ...........................................

Y17

Setting of pressure indicator in pressure units


specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C

Y21

Setting of pressure indicator in non-pressure units


specify in plain text:
Y22: ..... up to ..... l/min, m3/h, m, USgpm, ...
(specification of measuring range in pressure units
"Y01" or "Y02" is essential, unit with max. 5 characters)

Y22 +
Y01 or Y02

Only the settings for "Y01", "Y21", "Y22" and "D05" can be made in the
factory

Siemens FI 01 2005

2/47

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for level

Technical specifications

Measuring cell with silicone oil filling

SITRANS P pressure transmitters, DS III series, for level

- High-pressure side

pabs 1 bar: -40 ... +175 C


(-40 ... +347 F)
pabs < 1 bar: -40 ... +80 C
(-40 ... +176 F)

- Low-pressure side

-40 ... +100 C (-40 ... +212 F)


-20 ... +60 C (-4 ... +140 F) in
conjunction with dust explosion
protection

Input
Measured variable

Level

Span

Maximum working pressure


(nominal pressure)

25 ... 250 mbar (0.36 ... 3.63 psi)

See "Mounting flange"

25 ... 600 mbar (0.36 ... 8.7 psi)

Design

53 ... 1600 mbar (0.77 ...23.2 psi)

Weight (without options)

160 ... 5000 mbar


(2.32 ... 72.5 psi)

To DIN (pressure transmitter with


mounting flange, without tube)

11 ... 13 kg ( 24.2 ... 28.7 lb)

To ANSI (pressure transmitter with


mounting flange, without tube)

11 ... 18 kg ( 24.2 ... 39.7 lb)

Lower measuring limit (measuring


cell with silicone oil filling)

-100% of max. span or 30 mbar


(0.435 psi) abs., depending on
mounting flange

Upper measuring limit

100% of max. span

Output
Output signal

Wetted parts materials


High-pressure side: Seal diaphragm of mounting flange

Stainless steel, mat. No.


1.4404/316L,
Monel 400, mat. No. 2.4360,
Hastelloy B2, mat. No. 2.4617,
Hastelloy C276, mat. No. 2.4819,
Hastelloy C4, mat. No. 2.4610,
tantalum, PTFE, ECTFE

Measuring cell filling

Silicone oil

4 ... 20 mA

Measuring accuracy
Reference conditions

Increasing characteristic
Start-of-scale value 0 bar
Stainless steel seal diaphragm
Mounting flange without tube
Silicone oil filling
Room temperature (25 C (77 F))
r: Span ratio
(r = max. span / set span)

Process connection
High-pressure side

Flange to DIN and ANSI

Low-pressure side

Female thread -18 NPT and


flange connection to DIN 19213
with mounting thread M10 or
7/ -20 UNF to EN 61518
16

Error in measurement and fixedpoint setting (including hysteresis


and repeatability)
Power supply UH

Linear characteristic
- r 10

0.15%

- 10 < r 30

0.3%

- 30 < r 100

(0.0075 r + 0.075)%

Influence of ambient temperature


With -10 ... +60 C (14 ... 140 F)
- 250-mbar (3.63 psi) measuring
cell

(0.5 r + 0.2)% (0.4 instead of


0.2 with 10 < r 30)

- 600-mbar (8.7 psi) measuring


cell

(0.3 r + 0.2)% (0.4 instead of


0.2 with 10 < r 30)

- 1,600 and 5,000 mbar (23.2 and


72.5 psi) measuring cells

(0.25 r + 0.2)% (0.4 instead of


0.2 with 10 < r 30)

With -40 ... -10 C and


+60 C ... +85 C
(-40 ... +14 and 140 ... 185 F)
- 250-mbar (3.63 psi) measuring
cell

(0.25 r +0.15)% / 10 K
( (0.25 r +0.15)% / 18 F)
(Twice the value for 10 < r 30)

- 600-mbar (8.7 psi) measuring


cell

(0.15 r +0.15)% / 10 K
( (0.15 r +0.15)% / 18 F)
(Twice the value for 10 < r 30)

- 1,600 and 5,000 mbar (23.2 and


72.5 psi) measuring cells

(0.12 r +0.15)% / 10 K
( (0.12 r +0.15)% / 18 F)
(Twice the value for 10 < r 30)

Rated conditions
Degree of protection (to EN 60529)

IP65

Process temperature

Note: Note the assignment of the


max. permissible operating temperature to the max. permissible
operating pressure of the respective flange connection!

2/48

Siemens FI 01 2005

Terminal voltage on pressure transmitter

10.5 ... 45 V DC
10.5 ... 30 V DC in intrinsicallysafe mode

Certificates and approvals


Classification according to pressure
equipment directive
(DRGL 97/23/EC)

For gases of fluid group 1 and


liquids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)

Explosion protection
Intrinsic safety "i"

PTB 99 ATEX 2122

- Identification

Ex II 1/2 G EEx ia/ib IIB/IIC T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +70 C (-40 ... +158 F)
temperature class T5;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To certified intrinsically-safe circuits with maximum values:


Ui = 30 V, Ii = 100 mA,
Pi = 750 mW; Ri = 300

- Effective internal inductance/capacitance

Li = 0.4 mH, Ci = 6 nF

Explosion-proof "d"

PTB 99 ATEX 1160

- Identification

Ex II 1/2 G EEx d IIC T4/T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To circuits with values:


UH = 10.5 ... 45 V DC

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for level
Dust explosion protection for
zone 20

PTB 01 ATEX 2055

- Identification

Ex II 1 D IP65 T 120 C
Ex II 1/2 D IP65 T 120 C

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)

- Max.surface temperature

120 C (248 F)

- Connection

To certified intrinsically-safe circuits with maximum values:


Ui = 30 V, Ii = 100 mA,
Pi = 750 mW, Ri = 300

- Effective internal inductance/capacitance


Dust explosion protection for zone
21/22

Li = 0.4 mH, Ci = 6 nF

Ex II 2 D IP65 T 120 C

- Connection

To circuits with values:


UH = 10.5 ... 45 V DC;
Pmax = 1.2 W

- Identification
Explosion protection to FM
- Identification (XP/DIP) or (IS);
(NI)

Explosion protection to CSA


- Identification (XP/DIP) or (IS)

Nom. diam.

Nom. press.

To EN 1092-1
- DN 80

PN 40

- DN 100

PN 16
PN 40

To ASME B16.5
- 3 inch

class 150
class 300

- 4 inch

class 150
class 300

PTB 01 ATEX 2055

- Identification

Type of protection "n" (zone 2)

Mounting flange

TV 01 ATEX 1696 X
Ex II 3 G EEx nA L IIC T4/T5/T6
Certificate of Compliance
3008490
CL I, DIV 1, GP ABCD T4...T6;
CL II, DIV 1, GP EFG; CL III; CL I,
ZN 0/1 AEx ia IIC T4...T6; CL I,
DIV 2, GP ABCD T4...T6; CL II,
DIV 2, GP FG; CL III
Certificate of Compliance
1153651
CL I, DIV 1, GP ABCD T4...T6;
CL II, DIV 1, GP EFG; CL III; Ex ia
IIC T4...T6; CL I, DIV 2, GP ABCD
T4...T6; CL II, DIV 2, GP FG; CL III

Siemens FI 01 2005

2/49

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for level

Dimensional drawings
approx. 30 (1.18)5)

185
100 (3.94)

138 (5.4)
69 (2.72)

50
(1.97)

15
(0.6)

77 (3)4)

165 (6.5)

51)

54 (2.1)

8
d5
d4

108 (4.25)
Space for rotation
of housing

nxd 2
b

approx. 96 (3.78)

1
2
3

4
5
6
8
9
1)
2)
3)
4)
5)

Process connection of low pressure side -18 NPT (EN 61 518)


Blanking plug
Electrical connection:
screwed gland Pg 13.5 (adapter) 2) 3),
screwed gland M20x1.5, screwed gland -14 NPT or
Han 7D/ Han 8U plug 2) 3)
Terminal side
Electronics side, digital display (longer overall length for cover with window)
Protective cover over keys
Sealing screw with valve (option)
Screw cover safety bracket (only for type of protection "Explosion-proof enclosure",
not shown in the drawing)

51)

41)

Allow approx. 20 mm (0.79 inch) thread length in addition


Not with type of protection "Explosion-proof enclosure"
Not with type of protection "FM + CSA [is + xp]"
92 mm (3.62 inch) for minimum distance to permit rotation without indicator
Approx. 45 mm (1.77 inch) for Pg 13.5 with adapter

SITRANS P pressure transmitters, DS III series for level, including mounting flange, dimensional drawing, dimensions in mm (inch)

Connection to EN 1092-1
Nom. diam.

Nom. press.

d2

d4

d5

dM

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm
0, 50, 100,
150 or 200

DN 80

PN 40

24

200

90

18

138

76

72 1)

160

DN 100

PN 40

20

220

115

18

158

94

89

180

PN 40

24

235

115

22

162

94

89

190

Connection to ASME B16.5


Nom. diam.
3 inch

4 inch

Nom. press. b

d2

d4

d5

lb/sq.in.

inch (mm)

inch (mm)

inch (mm)

inch (mm)

inch (mm) inch (mm) inch (mm) inch (mm)

150

0.94
(23.8)

7.5
(190.5)

0.75
(19.0)

5
(127)

3
(76)

2.81 1)
(72)

0.06
(1.6)

6
(152.4)

300

1.12
(28.6)

8.25
(209.5)

0.87
(22.2)

5
(127)

3
(76)

2.81 1)
(72)

0.06
(1.6)

6.69
(168.3)

150

0.94
(23.8)

9
(228.5)

0.75
(19.0)

6,19
(157.2)

3.69
(94)

3.5
(89)

0.06
(1.6)

7.5
(190.5)

300

1.25
(31.7)

10
(254)

0.87
(22.2)

6,19
(157.2)

3.69
(94)

3.5
(89)

0.06
(1.6)

7.88
(200)

d: Internal diameter of gasket to DIN 2690


dM: Effective diaphragm diameter

2/50

Siemens FI 01 2005

1)

dM

89 mm = 3 inch with tube length L = 0.

L
inch (mm)
0, 2, 3.94,
5.94 or 7.87
(0, 50, 100,
150 or 200)

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for level
Selection and Ordering data

Order No.

Further designs

SITRANS P pressure transmitters, DS III series


for level

7MF 4 6 3 3 -

Please add "-Z" to Order No. and specify Order code.

2-wire system

77 Y77 - 7777

Measuring cell filling


Silicone oil

Measuring cell cleaning


Standard

Measured span
25 ... 250 mbar
25 ... 600 mbar
53 ... 1600 mbar
0.16 ... 5 bar

(0.363 ... 3.63 psi)


(0.363 ... 8.70 psi)
(0.77 ... 23.2 psi)
(2.32 ... 72.5 psi)

Process connection of low-pressure side


Female thread -18 NPT with flange connection
Mounting thread M10 to DIN 19213
Mounting thread 7/16-20 UNF to EN 61518

D
E
F
G

Die-cast aluminium
Stainless steel precision
casting

O-rings for process flanges


(instead of FPM (Viton))
PTFE (Teflon)
FEP (with silicone core, approved for food)
FFPM (Kalrez, compound 4079)
NBR (Buna N)

A20
A21
A22
A23

Plug
Han 7D (metal, gray)
Han 8U (instead of Han 7D)

A30
A31

Sealing screws
-18 NPT, with valve in material of process flanges
0
2

Rating plate inscription


(instead of German)
English
French
Spanish
Italian

Non-wetted parts materials


Process flange screws Electronics housing
Stainless steel
Stainless steel

Order code

2
3

Design
Standard design
International version, English label inscriptions,
documentation in 5 languages on CD
Explosion protection
without
with ATEX, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 1)
- "Intrinsic safety and explosion-proof enclosure
(EEx ia + EEx d)" 2)
- "n (zone 2)"
- "Intrinsic safety, explosion-proof enclosure and
dust explosion protection (EEx ia + EEx d +
zone 1D/2D)" 2)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 1)
Electrical connection / cable inlet
Screwed gland Pg 13.5 3)
Screwed gland M20x1.5
Screwed gland -14 NPT
Han 7D plug (plastic housing) incl. mating
connector 3)
Display
without (digital indicator hidden, setting: mA)
with visible digital indicator
with customer-specific digital indicator (setting
as specified, Order code "Y21" required)

1
2

A
B
D
P
E
R

NC
A
B
C
D

1
6
7

A40

B11
B12
B13
B14

English rating plate


Pressure units in inH2O or psi

B21

Manufacturer's test certificate M


(calibration certificate)
to DIN 55350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10204-3.1.B

C12

Factory certificate
to EN 10204-2.2

C14

Certificate "Functional Safety (SIL)"

C20

Setting of upper limit of output signal to 22.0 mA

D05

Type of protection IP68


(not together with Han 7D / Han 8U plug,
Pg 13.5 screwed gland)

D12

Use in or at zone 1D/2D


(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

Overfilling safety device for flammable and


non-flammable liquids
(max. PN 32, only together with type of protection
"Intrinsic safety (EEx ia)"), to WHG and VbF

E08

Interchanging of process connection side

H01

Ordering information:
1st order item: Pressure transmitter 7MF4633-...
2nd order item: Mounting flange 7MF4912-3...
Example of ordering:
Item line 1:
7MF4633-1EY20-1AA1-Z
B line:
Y01
C line:
Y01: 80 to 143 mbar (1.16 to 2.1 psi)
Item line 2:
7MF4912-3GE01
Power supply units see "SITRANS I power supply units and input isolators".
Included in delivery of the device:
Brief instructions (Leporello)
CD-ROM with detailed documentation
Sealing plug(s) or sealing screw(s) for the process flanges(s)
1) Without cable gland, with blanking plug
2) With enclosed cable gland EEx ia and blanking plug
3) Not together with type of protection "Explosion-proof"

Siemens FI 01 2005

2/51

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III series for level

Selection and Ordering data

Order No. Ord. code

Please add "-Z" to Order No. and specify Order code.

Order code

Mounting flange

7MF 4 9 1 2 -

Additional data

directly fitted to pressure transmitter


SITRANS P (converter part) for level,
for DS III series

3 7777

Further designs

Measuring range to be set


specify in plain text:
Y01: ... up to ... mbar, bar, kPa, MPa, psi

Y01

Measuring point number/identification


max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Entry of HART address (TAG)


max. 8 characters, specify in plain text:
Y17: ...........................................

Y17

Setting of pressure indicator in pressure units


specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C

Y21

Setting of pressure indicator in non-pressure units


specify in plain text:
Y22: ..... up to ..... l/min, m3/h, m, USgpm, ...
(specification of measuring range in pressure units
"Y01" is essential, unit with max. 5 characters)

Y22 1)+ Y01

Only the settings for "Y01", "Y21", "Y22" and "D05" can be made in the
factory
1) Not together with over-filling safety device for flammable and
non-flammable liquids (Order code "E08")

Selection and Ordering data

Order No. Ord. code

Mounting flange

7MF 4 9 1 2 -

directly fitted to pressure transmitter


SITRANS P (converter part) for level,
for DS III series

3 7777

Connection to EN 1092-1
Nom. diam.
Nom. press.
DN 80
PN 40
DN 100
PN 16
PN 40
Connection to ASME B16.5
Nom. diam.
Nom. press.
3 inch
Class 150
Class 300
4 inch
Class 150
Class 300
Other version
Add Order code and plain text:
Nominal diameter: ...; Nominal pressure: ...

2/52

Siemens FI 01 2005

777

Wetted parts materials


Stainless steel 316L
- Coated with PFA 1)
- Coated with PTFE 1)
- Coated with ECTFE 1)

A
D
E0
F

Monel 400, mat. No. 2.4360


Hastelloy B2, mat. No. 2.4617
Hastelloy C276, mat. No. 2.4819
Hastelloy C4, mat. No. 2.4610
Tantalum

G
H
J
U
K

Other version
Add Order code and plain text:
Wetted parts materials: ...
Sealing face, see "Technical data"

Tube length
without
50 mm
(1.97 inch)
100 mm
(3.94 inch)
150 mm
(5.90 inch)
200 mm
(7.87 inch)
Other version:
Add Order code and plain text:
Tube length: ...
Filling liquid
Silicone oil M5
Silicone oil M50
High-temperature oil
Halocarbon oil (for O2 measurements)
Vegetable
Glycerin / water2)
Other version
Add Order code and plain text:
Filling liquid: ...

777

K1Y

0
1
2
3
4
9

L1Y

1
2
3
4
5
6
9

M1 Y

Ordering example see previous page


1) For vacuum on request
2) Not suitable for use in low-pressure range

D
G
H

Further designs

Order code

Please add "-Z" to Order No. and specify Order code.


Q
R
T
U
Z

J1Y

Spark arrestor
for mounting on zone 0 (including documentation)

A01

Manufacturer's test certificate M


to DIN 55.350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10 204-3.1B

C12

Vacuum-proof design
(for use in low-pressure range)

V04

Calculation of span of associated pressure


transmitter
(enclose filled-in questionnaire with order)
Note:
Suffix "Y01" required with pressure transmitter

Y05

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series (PROFIBUS)

Overview

SITRANS P pressure transmitters of the DS III PA series are digital pressure transmitters featuring extensive user-friendliness
and high accuracy. Parameterization is performed using input
keys or through the PROFIBUS interface.
Extensive functionality enables the pressure transmitter to be
precisely adapted to the plants requirements. Operation is very
simple in spite of the numerous setting options.
Transmitters with type of protection "Intrinsic safety" and "Explosion-proof" may be installed within potentially explosive atmospheres (zone 1) or in zone 0. The transmitters are provided with
an EC type examination certificate and comply with the corresponding harmonized European standards (ATEX).
The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of
highly viscous substances.
Various versions of the DS III PA pressure transmitters are available for measuring:
Pressure
Absolute pressure
Differential pressure
Level
Volume
Volume flow
Mass flow

Benefits
High quality and long life
High reliability even under extreme chemical and mechanical
loads
For aggressive and non-aggressive gases, vapors and liquids
Extensive diagnosis and simulation functions
Separate replacement of measuring cell and electronics without recalibration
Minimum conformity error
Small long-term drift
Wetted parts made of high-grade materials (stainless steel,
Hastelloy, gold, Monel, tantalum)
Choice of several nominal measuring ranges

High measuring accuracy


Parameterization using input keys and PROFIBUS PA, profile
3.0

Application
SITRANS P pressure transmitters, DS III PA series, can be used
in industrial areas with extreme chemical and mechanical loads.
Electromagnetic compatibility in the range 10 kHz to 1 GHz
makes the DS III PA pressure transmitters suitable for locations
with high electromagnetic emissions.
Pressure transmitters with type of protection "Intrinsic safety" and
"Explosion-proof" may be installed within potentially explosive atmospheres (zone 1) or in zone 0. The pressure transmitters are
provided with an EC type examination certificate and comply
with the corresponding harmonized European standards of the
CENELEC.
Pressure transmitters with the type of protection "Intrinsic safety"
for use in zone 0 may be operated with power supply units of category "ia" and "ib".
The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of
highly viscous substances.
Pressure transmitters for pressure
Measured variable: Pressure of aggressive and non-aggressive
gases, vapors and liquids.
Measured spans: 0.01 ... 400 bar (0.145 ... 5802 psi)
Pressure transmitters for absolute pressure
Measured variable: Absolute pressure of aggressive and nonaggressive gases, vapors and liquids.
Measured spans: 8.3 mbar ... 100 bar (0.12 ... 1450 psi)
There are two series:
Pressure series
Differential pressure series

Siemens FI 01 2005

2/53

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series (PROFIBUS)

Pressure transmitters for level


Measured variable: Level of aggressive and non-aggressive liquids in open and closed vessels.
Nominal measuring ranges: 25 mbar ... 5 bar (0.363 ... 72.5 psi)
Nominal diameter of the mounting flange:
DN 80 or DN 100
3 inch or 4 inch

At the top of the housing is a plastic cover (5), under which the
input keys can be found.

Function
Mode of operation of the electronics

In the case of level measurements in open containers, the lowpressure connection of the measuring cell remains open
(measurement "compared to atmospheric").

0 0 00 0
00

In the case of measurements in closed containers, the lowerpressure connection has to be connected to the container in order to compensate the static pressure.

mC

The wetted parts are constructed from a variety of materials depending on the degree of corrosion resistance required.

Design

EEPROM

7
PA
interface

Electronics
1

Sensor
pe

1
2
3
4
5
6
7

Power supply
10
Power
supply
unit

PROFIBUS-DP

Nominal measuring ranges: 1 mbar ... 30 bar


(0.0145 ... 435 psi)

The electrical connections for the power supply and screen are
accessible by unscrewing the rear cover. The bottom part of the
housing contains the measuring cell with process connection
(1). The measuring cell is protected from rotating by a locking
screw (8). As the result of this modular design, the measuring
cell and the electronics can be replaced separately from each
other. The set parameter data are retained.

PROFIBUS-PA

Measured variables:
Differential pressure
Small positive or negative pressure
Flow q ~ p (together with a primary differential pressure device)

pane so that the measured values can be read directly on the digital display. The inlet (4) for the electrical connection is located
either on the left or right side. The unused opening on the opposite side is sealed by a blanking plug. The protective earth connection is located on the rear of the housing.

Coupler

11
12

BusMaster

EEPROM

Pressure transmitters for differential pressure and flow

Measuring cell

Measuring cell sensor


Instrument amplifier
Analog-to-digital converter
Microcontroller
Electrical isolation
One non-volatile memory
each in the measuring cell
and electronics
PROFIBUS-PA interface

8
9
10
11
12

Three input keys


(local operation)
Digital display
Power supply
DP/PA coupler or link
Bus master

pe

Input variable

Function diagram of the electronics

Front view

The transmitter consists of various components depending on


the order. The possible versions are listed in the ordering information. The components described below are the same for all
transmitters.
The rating plate (3, Figure "Front view") with the Order No. is located on the side of the housing. The specified number together
with the ordering information provide details on the optional design details and on the possible measuring range (physical properties of built-in sensor element).
The approval label is located on the opposite side.
The housing is made of die-cast aluminium or stainless steel precision casting. A round cover is screwed on at the front and rear
of the housing. The front cover (6) can be fitted with a viewing

2/54

Siemens FI 01 2005

The bridge output voltage created by the sensor (1, Figure


"Function diagram of the electronics") is amplified by the instrument amplifier (2) and digitized in the analog-to-digital converter
(3). The digital information is evaluated in the microcontroller, its
linearity and temperature response corrected, and provided on
the PROFIBUS PA through an electrically isolated PA interface
(7).
The data specific to the measuring cell, the electronics data, and
the parameter data are stored in the two non-volatile memories
(6). The one memory is coupled to the measuring cell, the other
to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from
each other.
Using the three input keys (8) you can parameterize the pressure
transmitter directly at the point of measurement. The input keys
can also be used to control the view of the results, the error messages and the operating modes on the digital display (9).

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series (PROFIBUS)
The results with status values and diagnostic values are transferred by cyclic data transmission on the PROFIBUS PA. Parameterization data and error messages are transferred by acyclic
data transmission. Special software such as SIMATIC PDM is required for this.

Measuring cell for absolute pressure from differential pressure


series

Mode of operation of the measuring cells

Measuring cell for pressure


5
pe

6
5
4

1
2
3
4
5
pe

Measuring cell
Process connection
Seal diaphragm
Filling liquid
Silicon pressure sensor
Pressure as input variable

2
p

Measuring cell for pressure, functional diagram

Measuring cell for absolute pressure from pressure series


The pressure pe is applied through the process connection (2,
Figure "Measuring cell for pressure, functional diagram) to the
measuring cell (1). This pressure is subsequently transmitted
further through the seal diaphragm (3) and the filling liquid (4) to
the silicon pressure sensor (5) whose measuring diaphragm is
then flexed. The resistance of the four piezo-resistors fitted in the
diaphragm in a bridge circuit thus changes. This change in resistance results in a bridge output voltage proportional to the absolute pressure.

The input pressure pe is transmitted through the seal diaphragm


(6, Figure "Measuring cell for absolute pressure from differential
pressure series, functional diagram") and the filling liquid (8) to
the silicon pressure sensor (3).
The difference in pressure between the input pressure pe and
the reference vacuum (1) on the low-pressure side of the measuring cell flexes the measuring diaphragm. The resistance of the
four piezo-resistors fitted in the diaphragm in a bridge circuit
thus changes. This change in resistance results in a bridge output voltage proportional to the absolute pressure.
An overload diaphragm is installed to provide protection from
overloads. If the measuring limits are exceeded, the overload diaphragm (2) is flexed until the seal diaphragm rests on the body
of the measuring cell (7), thus protecting the silicon pressure
sensor from overloads.
Measuring cell for differential pressure and flow

5
1

3
1

pe

1
2
3
4
5
pe

Measuring cell
Process connection
Seal diaphragm
Filling liquid
Silicon absolute pressure sensor
Absolute pressure as input variable

Measuring cell for absolute pressure from the pressure series, functional
diagram

The absolute pressure pe is transmitted through the seal diaphragm (3, Figure "Measuring cell for absolute pressure from
pressure series, functional diagram") and the filling liquid (4) to
the silicon absolute pressure sensor (5) whose measuring diaphragm is then flexed. The resistance of the four piezo-resistors
fitted in the diaphragm in a bridge circuit thus changes. This
change in resistance results in a bridge output voltage proportional to the input pressure.

Reference vacuum
Overload diaphragm
Silicon pressure sensor
O-ring
Process flange
Seal diaphragm
Body of measuring cell
Filling liquid
Absolute pressure as
input variable

Measuring cell for absolute pressure from differential pressure series,


functional diagram

1
2
3
4
5
6
7
8
pe

1
5

1
2
3
4
5
6
7

Seal diaphragm
O-ring
Overload diaphragm
Silicon pressure sensor
Process flange
Body of measuring cell
Filling liquid

Measuring cell for differential pressure and flow, functional diagram

The differential pressure is transmitted through the seal diaphragms (1, Figure "Measuring cell for differential pressure and
flow, functional diagram") and the filling liquid (7) to the silicon
pressure sensor (4).
The measuring diaphragm is flexed by the applied differential
pressure. The resistance of the four piezo-resistors fitted in the
diaphragm in a bridge circuit thus changes. This change in resistance results in a bridge output voltage proportional to the absolute pressure.
An overload diaphragm is installed to provide protection from
overloads. If the measuring limits are exceeded, the overload diaphragm (2) is flexed until the seal diaphragm rests on the body
of the measuring cell (7), thus protecting the silicon pressure
sensor from overloads.

Siemens FI 01 2005

2/55

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series (PROFIBUS)

Adjustable parameters

Measuring cell for level

Parameters
3

8
+

10

1
2
3
4
5

Flange with tube


Seal diaphragm on
mounting flange
Seal diaphragm
Body of measuring cell
Overload diaphragm

6
7
8
9
10

Silicon pressure sensor


O-ring
Process flange
Filling liquid
Capillary with filling liquid
of mounting flange

Measuring cell for level, functional diagram

The input pressure (hydrostatic pressure) acts hydraulically on


the measuring cell through the seal diaphragm on the mounting
flange (2, Figure "Measuring cell for level, functional diagram").
This differential pressure is subsequently transmitted further through the measuring cell (3) and the filling liquid (9) to the silicon
pressure sensor (6) whose measuring diaphragm is then flexed.
The resistance of the four piezo-resistors fitted in the diaphragm
in a bridge circuit thus changes.
This change in resistance results in a bridge output voltage proportional to the differential pressure.
An overload diaphragm is installed to provide protection from
overloads. If the measuring limits are exceeded, the overload diaphragm (2) is flexed until the seal diaphragm rests on the body
of the measuring cell (7), thus protecting the silicon pressure
sensor from overloads.

Zero adjustment (correction of


position)

Keys and/or function disabling

Source of measured-value display x

Physical dimension of display

Bus address

Adjustment of characteristic

Input of characteristic

Freely-programmable LCD

Diagnostics functions

Diagnostic functions
Event counter
Slave pointer
Maintenance timer
Simulation functions
Display of zero correction
Limit transmitter
Saturation alarm
Physical dimensions available for the display
Physical variable

Physical dimensions

Pressure (setting can also be made


in the factory)

MPa, hPa, kPa, Pa, bar, mbar, torr,


atm, psi, g/cm2, kg/cm2, mmH20,
mmH20 (4 C), inH20, inH20
(4 C), ftH20, mmHg, inHg

Level (height data)

m, cm, mm, ft, in, yd

Volume

m3, dm3, hl, yd3, ft3, in3, US gallon, lmp, gallon, bushel, barrel,
barrel liquid

Volume flow

m3/s, m3/min, m3/h, m3/d, l/s,


l/min, l/h, l/ d, Ml/d, ft3/s, ft3/min,
ft3/h, ft3/d, US gallon/s, US gallon/min, US gallon/h, US gallon/d, bbl/s, bbl/min, bbl/h, bbl/d

Mass flow

g/s, g/min, g/h, g/d, kg/s, kg/min,


kg/h, kg/d, t/s, t/min, t/h, /t/d, lb/s,
lb/min, lb/h, lb/d, STon/s,
STon/min, STon/h, STon/d, LTon/s,
LTon/min, LTon/h, LTon/d

Total mass flow

t, kg, g, lb, oz, LTon, STon

Parameterization through PROFIBUS PA interface


Fully digital communication through PROFIBUS PA, profile 3.0,
is particularly user-friendly. The PROFIBUS puts the DS III PA is
in connection with a process control system, e.g.
SIMATIC PSC 7. Communication is possible even in a potentially
explosive environment.
For parameterization through PROFIBUS you need suitable software, e.g. SIMATIC PDM (Process Device Manager).

2/56

Siemens FI 01 2005

Position of decimal point

Parameterization using the input keys (local operation)


With the input keys you can easily set the most important parameters without any additional equipment.

PROFIBUS
interface

Electrical damping

Parameterization
Depending on the version, there are different possibilities for parameterizing the pressure transmitter and for setting or scanning
the parameters.

Input keys

Temperature

K, C, F, R

Miscellaneous

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for pressure

Technical specifications

Power supply UH

SITRANS P pressure transmitters, DS III PA series for pressure


Input

Bus voltage

Measured variable

Pressure

Not Ex

9 ... 32 V

Nominal measuring range

Max. working pressure

With intrinsically-safe operation

9 ... 24 V

1 bar (14.5 psi)

6 bar (87 psi)

Current consumption

4 bar (58 psi)

10 bar (145 psi)

Basic current (max.)

12.5 mA

16 bar (232 psi)

32 bar (464 psi)

Max. current in event of fault

15.5 mA

63 bar (913 psi)

100 bar (1450 psi)

Certificate and approvals

160 bar (2320 psi)

250 bar (3626 psi)

400 bar (5802 psi)

500 bar (7252 psi)

Classification according to pressure


equipment directive
(DRGL 97/23/EC)

Lower measuring limit


Measuring cell with silicone oil filling

30 mark (0.435 psi) absolute

Upper measuring limit

100% of nominal measuring


range (max. 160 bar (2320 psi)
with oxygen measurement and
inert filling liquid)
Digital PROFIBUS PA signal

Physical bus

IEC 61158-2

Intrinsic safety "i"

Increasing characteristic, start-ofscale value 0 bar, stainless steel


seal diaphragm, silicone oil filling,
room temperature (25 C (77 F))

Ex II 1/2 G EEx ia/ib IIB/IIC T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +70 C (-40 ... +158 F)
temperature class T5;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To a certified intrinsically-safe circuit with maximum values:


FISCO supply unit:
Uo = 17.5 V, Io = 380 mA,
Po = 5.32 W
Linear barrier:
Uo = 24 V, Io = 250 mA,
Po = 1.2 W

- Effective internal inductance/capacitance

Li = 7 H, Ci = 1.1 nF

Error in measurement (including


hysteresis and repeatability)
0.075%

Rated conditions
Degree of protection (to EN 60529)

IP65

Process temperature

Explosion-proof "d"

Measuring cell with silicone oil filling

-40 ... +100 C (-40 ... +212 F)

Measuring cell with inert filling liquid

-20 ... +100 C (-4 ... +212 F)

In conjunction with dust explosion


protection

-20 ... +60 C (-4 ... +140 F)

0.3%

With -40 ... -10 C and


+60 C ... +85 C
(-40 ... +14 and 140 ... 185 F)

0.25% / 10 K ( 0.25% / 18 F)

Design
Weight (without options)

1.5 kg ( 3.3 lb)

Wetted parts materials


Connection shank

Stainless steel, mat. No.


1.4404/316L or
Hastelloy C4, mat. No. 2.4610

Seal diaphragm

Stainless steel, mat. No.


1.4404/316L or
Hastelloy C276, mat. No. 2.4819

Measuring cell filling

Silicone oil or inert filling liquid


(max. 160 bar (2320 psi) with oxygen measurement)

Process connection

Connection shank GA to DIN


EN 837, female thread -14 NPT
or oval flange (PN 160
(MWP 2320)) to DIN 19213 with
mounting thread M10 or
7/ -20 UNF to EN 61518
16

PTB 99 ATEX 1160

- Identification

Ex II 1/2 G EEx d IIC T4/T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To circuits with values:


UH = 9 ... 32 V DC

Influence of ambient temperature


With -10 ... +60 C (14 ... 140 F)

PTB 99 ATEX 2122

- Identification

Measuring accuracy

- Linear characteristic

For gases of fluid group 1 and


liquids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)

Explosion protection

Output

Reference conditions

Supplied through bus

Separate 24 V power supply neces- No


sary

Dust explosion protection for


zone 20

PTB 01 ATEX 2055

- Identification

Ex II 1 D IP65 T 120 C
Ex II 1/2 D IP65 T 120 C

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)

- Max.surface temperature

120 C (248 F)

- Connection

To a certified intrinsically-safe circuit with maximum values:


FISCO supply unit:
Uo = 17.5 V, Io = 380 mA,
Po = 5.32 W
Linear barrier:
Uo = 24 V, Io = 250 mA,
Po = 1.2 W

- Effective internal inductance/capacitance

Li = 7 H, Ci = 1.1 nF

Dust explosion protection for


zone 21/22

PTB 01 ATEX 2055

- Identification

Ex II 2 D IP65 T 120 C

- Connection

To circuits with values:


UH = 9 ... 32 V DC; Pmax = 1.2 W

Type of protection "n" (zone 2)

Planned

Siemens FI 01 2005

2/57

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for pressure
Explosion protection to FM

Certificate of Compliance
3008490

- Identification (XP/DIP) or (IS);


(NI)

Explosion protection to CSA

CL I, DIV 1, GP ABCD T4...T6;


CL II, DIV 1, GP EFG; CL III; CL I,
ZN 0/1 AEx ia IIC T4...T6; CL I,
DIV 2, GP ABCD T4...T6; CL II,
DIV 2, GP FG; CL III
Certificate of Compliance
1153651

- Identification

CL I, GP ABCD; CL II, GP EFG;


CL III; Enclosure Type 4X, CL I,
DIV 2, GP ABCD; CL II, DIV 2,
GP FG; CL III; Enclosure Type 4X

Dimensional drawings
55
(0.6)

1)

120 (4.7)

72 (2.8)

36,5
(1,44)

117 (4.6)
1)

100 (3.94)

68 (2.7)

ca. 30 (1.2)

28
(1.1)

50
(1.97)

50
(1.97)

69
(2.7)

123 (4.8)
min. 77 (3.0) 2)

7
105 (4.1)

2
3

4
5
6
7
8

Process connection:
- -14 NPT,
- connection shank GA or
- oval flange
Blanking plug
Electrical connection:
- screwed gland M20x1,5 4),
- screwed gland -14 NPT or
- PROFIBUS plug M12 3) 4)
Terminal side
Electronics side, digital display (longer overall
length for cover with window)
Protective cover over keys
Mounting bracket (option)
Screw cover safety bracket (only for explosion-proof enclosure,
not shown in the drawing)

1)
2)
3)
4)

Allow approx. 20 mm (0.79 inch) thread length in addition


Minimum distance for rotating
Not with type of protection "Explosion-proof enclosure".
Not with type of protection "FM + CSA".

SITRANS P pressure transmitters, DS III PA series for pressure, dimensional drawing, dimensions in mm (inch)

2/58

Siemens FI 01 2005

171 (6.7)
237 (9.3)

138 (5.4)

20
(0.8)

15
(0.6)

80
(3.15)

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for pressure
Selection and Ordering data

Order No.

Further designs

SITRANS P pressure transmitter for pressure

7MF 4 0 3 4 -

Please add "-Z" to Order No. and specify Order code.

DS III PA series

77777 - 7777

Pressure transmitter with mounting bracket made of:


Steel
A01
Stainless steel
A02

Measuring cell filling


Silicone oil
Inert liquid

Measuring cell cleaning


Standard
Grease-free

Rated measuring range


1 bar
(14.5 psi)
4 bar
(58 psi)
16 bar
(232 psi)
63 bar
(914 psi)
160 bar
(2320 psi)
400 bar
(5802 psi)

1
3

Rating plate inscription


(instead of German)
English
French
Spanish
Italian

B
C
D
E
F
G

Wetted parts materials


Seal diaphragm
Process connection
Stainless steel
Stainless steel
Hastelloy
Stainless steel
Hastelloy
Hastelloy
Version as diaphragm seal
Process connection
Connection shank GB to EN 837-1
Female thread -14 NPT
Oval flange made of stainless steel,
max. span 160 bar (2320 psi)
- Mounting thread 7/16-20 UNF to EN 61518
- Mounting thread M10 to DIN 19213
Non-wetted parts materials
Housing made of die-cast aluminium
Housing stainless steel precision casting
Design
Standard design
International version, English label inscriptions,
documentation in 5 languages on CD
Explosion protection
without
with CENELEC, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 1)
- "Intrinsic safety and explosion-proof enclosure
(EEx ia + EEx d)" 2)
- "n (zone 2)" (planned)
- "Intrinsic safety, explosion-proof enclosure and
dust explosion protection (EEx ia + EEx d +
zone 1D/2D)" 2)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 1)
Electrical connection / cable inlet
Screwed gland M20x1.5
Screwed gland -14 NPT
PROFIBUS plug M12 incl. mating connector 3)
Display
without (digital display hidden)
with visible digital indicator
with customer-specific digital indicator (setting
as specified, Order code "Y21" required)

Order code

A
B
C
Y0
0
1

2
3
0
3
1
2

A
B
D
P

B11
B12
B13
B14

English rating plate


Pressure units in inH2O or psi

B21

Manufacturer's test certificate M


to DIN 55.350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10 204-3.1B

C12

Factory certificate
to EN 10.204-2.2

C14

Acid gas version to NACE


(only together with seal diaphragm made of Hastelloy)

D07

Type of protection IP68


(not together with PROFIBUS plug M12 and nominal
measuring range 63 bar ( 914 psi))

D12

Digital indicator along side the input keys


(only together with the devices 7MF4034-....0-.A-6 or
-.A.7-Z, Y21)

D27

Use on zone 1D / 2D
(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

Oxygen application
(max. 160 bar (2320 psi) with oxygen measurement
and inert liquid)

E10

Additional data

E
R

NC
B
C
F
1
6
7

The device is delivered together with brief instructions (Leporello) and


a CD-ROM containing detailed documentation.
1) Without cable gland, with blanking plug
2) With enclosed cable gland EEx ia and blanking plug
3) Not together with types of protection "Explosion-proof" or "Intrinsic safety
und explosion-proof"

Measuring point number/identification


max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Setting of pressure indicator in pressure units


specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C

Y21

Preset bus address


specify in plain text (standard setting: 126)
Y25: ...........................................

Y25

Only the settings for "Y21" and "Y25" can be made in the factory
Ordering example
Item line: 7MF4034-1EA00-1AA7-Z
B line: A01 + Y21
C line: Y21: ... m

Siemens FI 01 2005

2/59

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for pressure

Technical specifications
SITRANS P pressure transmitters, DS III PA series for absolute
pressure, from the pressure series

Not Ex

9 ... 32 V

With intrinsically-safe operation

9 ... 24 V

Current consumption

Input

Basic current (max.)

12.5 mA

Measured variable

Absolute pressure

Max. current in event of fault

15.5 mA

Nominal measuring range

Max. working pressure

Certificates and approvals

250 mbar (3.6 psi)

6 bar (87 psi)

1300 mbar (18.9 psi)

10 bar (145 psi)

Classification according to pressure


equipment directive
(DRGL 97/23/EC)

5 bar (72.5 psi)

30 bar (435 psi)

30 bar (435 psi)

100 bar (1450 psi)

Lower measuring limit


Measuring cell with silicone oil filling

0 mbar absolute

Upper measuring limit

100% of nominal measuring


range (max. 160 bar (2320 psi)
with oxygen measurement and
inert filling liquid)

Output

Digital PROFIBUS PA signal

Physical bus

IEC 61158-2

Explosion protection
Intrinsic safety "i"

Ex II 1/2 G EEx ia/ib IIB/IIC T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +70 C (-40 ... +158 F)
temperature class T5;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To a certified intrinsically-safe circuit with maximum values:


FISCO supply unit:
Uo = 17.5 V, Io = 380 mA,
Po = 5.32 W
Linear barrier:
Uo = 24 V, Io = 250 mA,
Po = 1.2 W

- Effective internal inductance/


capacitance

Li = 7 H, Ci = 1.1 nF

Increasing characteristic
Start-of-scale value 0 bar
Stainless steel seal diaphragm
Silicone oil filling
Room temperature (25 C (77 F))

Error in measurement (including


hysteresis and repeatability)
- Linear characteristic

0.075%

Influence of ambient temperature


With -10 ... +60 C (14 ... 140 F)

0.3%

With -40 ... -10 C and


+60 ... +85 C
(-40 ... +14 and 140 ... 185 F)

0.25% / 10 K ( 0.25% / 18 F)

Rated conditions
Degree of protection (to EN 60529)

-40 ... +100 C (-40 ... +212 F)

In conjunction with dust explosion


protection

-20 ... +60 C (-4 ... +140 F)

Design
1.5 kg ( 3.3 lb)

Ex II 1/2 G EEx d IIC T4/T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To circuits with values:


UH = 9 ... 32 V DC

Stainless steel, mat. No.


1.4404/316L or
Hastelloy C4, mat. No. 2.4610

Seal diaphragm

Stainless steel, mat. No.


1.4404/316L or
Hastelloy C276, mat. No. 2.4819

Measuring cell filling

Silicone oil or inert filling liquid


(max. 160 bar (2320 psi) with oxygen measurement)

Process connection

Connection shank GA to DIN


EN 837, female thread -14 NPT
or oval flange (PN 160
(MWP 2320)) to DIN 19 213 with
mounting thread M10 or
7/ -20 UNF to EN 61518
16

Power supply UH

Supplied through bus

Separate 24 V power supply neces- No


sary
Bus voltage

2/60

Siemens FI 01 2005

PTB 01 ATEX 2055

- Identification

Ex II 1 D IP65 T 120 C
Ex II 1/2 D IP65 T 120 C

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)

- Max.surface temperature

120 C (248 F)

- Connection

To a certified intrinsically-safe circuit with maximum values:


FISCO supply unit:
Uo = 17.5 V, Io = 380 mA,
Po = 5.32 W
Linear barrier:
Uo = 24 V, Io = 250 mA,
Po = 1.2 W

- Effective internal inductance/


capacitance

Li = 7 H, Ci = 1.1 nF

Wetted parts materials


Connection shank

PTB 99 ATEX 1160

- Identification

Dust explosion protection for


zone 20

Measuring cell with silicone oil filling

Weight (without options)

Explosion-proof "d"

IP65

Process temperature

PTB 99 ATEX 2122

- Identification

Measuring accuracy
Reference conditions

For gases of fluid group 1 and


liquids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)

Dust explosion protection for


zone 21/22

PTB 01 ATEX 2055

- Identification

Ex II 2 D IP65 T 120 C

- Connection

To circuits with values:


UH = 9 ... 32 V DC; Pmax = 1.2 W

Type of protection "n" (zone 2)

Planned

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for absolute pressure
(from pressure series)
Explosion protection to FM

Certificate of Compliance
3008490

- Identification (XP/DIP) or (IS);


(NI)

Explosion protection to CSA

CL I, DIV 1, GP ABCD T4...T6;


CL II, DIV 1, GP EFG; CL III; CL I,
ZN 0/1 AEx ia IIC T4...T6; CL I,
DIV 2, GP ABCD T4...T6; CL II,
DIV 2, GP FG; CL III
Certificate of Complianc1153651

- Identification

CL I, GP ABCD; CL II, GP EFG;


CL III; Enclosure Type 4X, CL I,
DIV 2, GP ABCD; CL II, DIV 2,
GP FG; CL III; Enclosure Type 4X

Dimensional drawings
55
(0.6)

36,5
(1,44)

120 (4.7)

1)

68 (2.7)

117 (4.6)
1)

100 (3.94)

72 (2.8)

ca. 30 (1.2)

28
(1.1)

50
(1.97)

50
(1.97)

20
(0.8)

69
(2.7)

171 (6.7)
237 (9.3)

138 (5.4)

80
(3.15)

15
(0.6)

123 (4.8)
min. 77 (3.0) 2)

7
105 (4.1)

2
3

4
5
6
7
8

Process connection:
- -14 NPT,
- connection shank GA or
- oval flange
Blanking plug
Electrical connection:
- screwed gland M20x1,5 4),
- screwed gland -14 NPT or
- PROFIBUS plug M12 3) 4)
Terminal side
Electronics side, digital display (longer overall
length for cover with window)
Protective cover over keys
Mounting bracket (option)
Screw cover safety bracket (only for explosion-proof enclosure,
not shown in the drawing)

1)
2)
3)
4)

Allow approx. 20 mm (0.79 inch) thread length in addition


Minimum distance for rotating
Not with type of protection "Explosion-proof enclosure".
Not with type of protection "FM + CSA".

SITRANS P pressure transmitters, DS III PA series for absolute pressure from the pressure series, dimensional drawing, dimensions in mm (inch)

Siemens FI 01 2005

2/61

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for absolute pressure
(from pressure series)

Selection and Ordering data

Order No.

Further designs

SITRANS P pressure transmitters


for absolute pressure from the pressure series

7MF 4 2 3 4 -

Please add "-Z" to Order No. and specify Order code.

DS III PA series

77777 - 7777

Pressure transmitter with mounting bracket made of:


Steel
A01
Stainless steel
A02

Measuring cell filling


Silicone oil
Inert liquid

Measuring cell
cleaning
Standard
Grease-free

Rating plate inscription


(instead of German)
English
French
Spanish
Italian

1
3

Rated measuring range


250 mbar
(3.63 psi)
1300 mbar
(18.9 psi)
5 bar
(72.5 psi)
30 bar
(435 psi)

D
F
G
H

Wetted parts materials


Seal diaphragm
Process connection
Stainless steel
Stainless steel
Hastelloy
Stainless steel
Hastelloy
Hastelloy
Version as diaphragm seal 1)

E)
E)

Process connection
Connection shank GB to EN 837-1
Female thread -14 NPT
Oval flange made of stainless steel,
max. span 160 bar (2320 psi)
- Mounting thread 7/16-20 UNF to EN 61518
- Mounting thread M10 to DIN 19213
Non-wetted parts materials
Housing made of die-cast aluminium
Housing stainless steel precision casting
Design
Standard design
International version, English label inscriptions,
documentation in 5 languages on CD
Explosion protection
without
with CENELEC, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 2)
- "Intrinsic safety and explosion-proof enclosure
(EEx ia + EEx d)" 3)
- "n (zone 2)" (planned)
- "Intrinsic safety, explosion-proof enclosure and
dust explosion protection (EEx ia + EEx d +
zone 1D/2D)" 3)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 2)
Electrical connection / cable inlet
Screwed gland M20x1.5
Screwed gland -14 NPT
PROFIBUS plug M12 incl. mating connector 4)
Display
without (digital display hidden)
with visible digital indicator
with customer-specific digital indicator (setting
as specified, Order code "Y21" required)

A
B
C
Y0
0
1

2
3
0
3
1
2

Siemens FI 01 2005

English rating plate


Pressure units in inH2O or psi

B21

Manufacturer's test certificate M


to DIN 55.350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10 204-3.1B

C12

Factory certificate
to EN 10.204-2.2

C14

Acid gas version to NACE


(only together with seal diaphragm made of Hastelloy)

D07

Type of protection IP68


(not together with PROFIBUS plug M12)

D12

Digital indicator along side the input keys


(only together with the devices 7MF4234-....0-.A.6 or
-.A.7-Z, Y21)

D27

Use on zone 1D / 2D
(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

Oxygen application

E10

Additional data

B
D
P
E
R

NC
B
C
F
1
6
7

Version 7MF4233-1DY... only up to max. span 200 mbar (2.9 psi)


Without cable gland, with blanking plug
With enclosed cable gland EEx ia and blanking plug
Not together with types of protection "Explosion-proof" and "Intrinsic safety
und explosion-proof"
E) Combinations of the versions marked with E) are subject to the export
regulations AL: 2B230, ECCN: N.

2/62

B11
B12
B13
B14

The device is delivered together with brief instructions (Leporello) and


a CD-ROM containing detailed documentation.
1)
2)
3)
4)

Order code

Measuring point number/identification


max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Setting of pressure indicator in pressure units


specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C
Preset bus address

Y21

Y25

specify in plain text (standard setting: 126)


Y25: ...........................................
Only the settings for "Y21" and "Y25" can be made in the factory

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for absolute pressure
(from differential pressure series)

Technical specifications

Power supply

SITRANS P transmitters, DS III PA series for absolute pressure,


from the differential pressure series

Bus voltage

Mode of operation and system


design
Measuring principle

Piezo-resistive

Not Ex

9 ... 32 V

With intrinsically-safe operation

9 ... 24 V

Current consumption

Input
Measured variable

Absolute pressure

Basic current (max.)

12.5 mA

Nominal measuring range

Max. working pressure

Max. current in event of fault

15.5 mA

250 mbar (3.6 psi)

32 bar (464 psi)

Certificate and approvals

1300 mbar (18.9 psi)

32 bar (464 psi)

Classification according to pressure


equipment directive
(DRGL 97/23/EC)

5 bar (72.5 psi)

32 bar (464 psi)

30 bar (435 psi)

160 bar (2320 psi)

100 bar (1450 psi)

160 bar (2320 psi) with pressure


cover screws M10 and
7/ -20 UNF
16

Lower measuring limit


Measuring cell with silicone oil filling

0 mbar absolute

Upper measuring limit

100% of nominal measuring


range (max. 160 bar (2320 psi)
with oxygen measurement and
inert filling liquid)

Output

Digital PROFIBUS PA signal

Physical bus

IEC 61158-2
Increasing characteristic
Start-of-scale value 0 bar
Stainless steel seal diaphragm
Silicone oil filling
Room temperature (25 C (77 F))

Error in measurement (including


hysteresis and repeatability)

For gases of fluid group 1 and


liquids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)

Explosion protection
Intrinsic safety "i"

PTB 99 ATEX 2122

- Identification

Ex II 1/2 G EEx ia/ib IIB/IIC T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +70 C (-40 ... +158 F)
temperature class T5;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To a certified intrinsically-safe circuit with maximum values:


FISCO supply unit:
Uo = 17.5 V, Io = 380 mA,
Po = 5.32 W
Linear barrier:
Uo = 24 V, Io = 250 mA,
Po = 1.2 W

- Effective internal inductance/


capacitance

Li = 7 H, Ci = 1.1 nF

Measuring accuracy
Reference conditions

Supplied through bus

Separate 24 V power supply neces- No


sary

Explosion-proof "d"

PTB 99 ATEX 1160

0.075%

- Identification

Ex II 1/2 G EEx d IIC T4/T6

With -10 ... +60 C (14 ... 140 F)

0.3%

- Permissible ambient temperature

With -40 ... -10 C and


+60 C ... +85 C
(-40 ... +14 and 140 ... 185 F)

0.25% / 10 K ( 0.25% / 18 F)

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To circuits with values:


UH = 9 ... 32 V DC

- Linear characteristic
Influence of ambient temperature

Rated conditions
Degree of protection (to EN 60529)

IP65

Process temperature
- Measuring cell with silicone oil fil- -40 ... +100 C (-40 ... +212 F)
ling
-20 ... +60 C (-4 ... +140 F) in
conjunction with dust explosion
protection
Design
Weight (without options)

Dust explosion protection for


zone 20
- Identification

Ex II 1 D IP65 T 120 C
Ex II 1/2 D IP65 T 120 C

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)

- Max.surface temperature

120 C (248 F)

- Connection

To a certified intrinsically-safe circuit with maximum values:


FISCO supply unit:
Uo = 17.5 V, Io = 380 mA,
Po = 5.32 W
Linear barrier:
Uo = 24 V, Io = 250 mA,
Po = 1.2 W

- Effective internal inductance/


capacitance

Li = 7 H, Ci = 1.1 nF

4.5 kg ( 9.9 lb)

Wetted parts materials


- Seal diaphragm

Stainless steel, mat. No.


1.4404/316L,
Hastelloy C276, mat. No. 2.4819,
Monel, mat. No. 2.4360, tantalum
or gold

Measuring cell filling

Silicone oil or inert filling liquid


(max. 160 bar (2320 psi) with oxygen measurement)

Process connection

Female thread 1/4-18 NPT and


flange connection to DIN 19213
with mounting thread M10 or
7/ -20 UNF to EN 61518
16

PTB 01 ATEX 2055

Dust explosion protection for


zone 21/22

PTB 01 ATEX 2055

- Identification

Ex II 2 D IP65 T 120 C

- Connection

To circuits with values:


UH = 9 ... 32 V DC; Pmax = 1.2 W

Type of protection "n" (zone 2)

Planned

Siemens FI 01 2005

2/63

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for absolute pressure
(from differential pressure series)
Explosion protection to FM

Certificate of Compliance
3008490

- Identification (XP/DIP) or (IS);


(NI)

CL I, DIV 1, GP ABCD T4...T6;


CL II, DIV 1, GP EFG; CL III; CL I,
ZN 0/1 AEx ia IIC T4...T6; CL I,
DIV 2, GP ABCD T4...T6; CL II,
DIV 2, GP FG; CL III

Explosion protection to CSA

Certificate of Compliance
1153651

- Identification

CL I, GP ABCD; CL II, GP EFG;


CL III; Enclosure Type 4X, CL I,
DIV 2, GP ABCD; CL II, DIV 2,
GP FG; CL III; Enclosure Type 4X

Dimensional drawings
approx. 30 (1.2)

50
(1.97)

3
approx. 261 (10.3)

198 (7.8)

1
+

Space for rotation


of housing

10
8

7
11

72 (2.83)
105 (4.1)
1
2
3

4
5
6
7
8
9
10
11

Process connection: -18 NPT (EN 61518)


Blanking plug
Electrical connection:
- screwed gland M20x1,5 4),
- screwed gland -14 NPT or
- PROFIBUS plug M12 3) 4)
Terminal side
Electronic side, digital display (longer overall length for cover with window)
Protective cover over keys
Mounting bracket (option)
Sealing screw with valve (option)
Screw cover safety bracket (only for explosion-proof enclosure,
not shown in the drawing)
Lateral venting for liquid measurement
Lateral venting for gas measurement (suffix H02)

52 (2.05)

96 (3.8)

117 (4.6)

80
(3.15)
5 1)

1)

69 (2.7)
77 (3) 2)

100 (3.94)

50
(1.97)

138 (5.4)

20
(0.8)

15
(0.6)

134 (5.27)

68 (2.7)
120 (4.7)

1)
2)
3)
4)

Allow approx. 20 mm (0.79 inch) thread length in addition


92 mm (3.62 inch) for minimum distance to permit rotation with indicator
Not with type of protection "explosion-proof enclosure"
Not with type of protection "FM + CSA"

SITRANS P pressure transmitters, DS III PA series for absolute pressure from the differential pressure series, dimensional drawing, dimensions in mm
(inch)

2/64

Siemens FI 01 2005

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for absolute pressure
(from differential pressure series)

Selection and Ordering data

Order No.

Selection and Ordering data

Order No.

SITRANS P pressure transmitters


for absolute pressure from the series
Differential pressure

7MF 4 3 3 4 -

SITRANS P pressure transmitters


for absolute pressure from the series
Differential pressure

7MF 4 3 3 4 -

DS III PA series

77777 - 7777

DS III PA series

77777 - 7777

Measuring cell filling


Silicone oil
Inert liquid

Measuring cell cleaning


Standard
Grease-free

Rated measuring range


250 mbar
(3.63 psi)
1300 mbar
(18.9 psi)
5 bar
(72.5 psi)
30 bar
(435 psi)
100 bar
(1450 psi)

Display
without (digital display hidden)
with visible digital indicator
with customer-specific digital indicator (setting
as specified, Order code "Y21" required)

1
3
D
F
G
H
KE

Included in delivery of the device:


Brief instructions (Leporello)
CD-ROM with detailed documentation
Sealing plug(s) or sealing screw(s) for the process flanges(s)
1)
2)
3)
4)
5)

Version 7MF4334-1DY... only up to max. span 200 mbar (2.9 psi)


Not for nominal measuring range 100 bar (1450 psi).
Without cable gland, with blanking plug
With enclosed cable gland EEx ia and blanking plug
Not together with types of protection "Explosion-proof" and "Intrinsic safety
und explosion-proof"
E) Combinations of the versions marked with E) are subject to the export
regulations AL: 2B230, ECCN: N.

Wetted parts materials


Seal diaphragm
Parts of measuring cell
Stainless steel
Stainless steel
Hastelloy
Stainless steel
Hastelloy
Hastelloy
Tantalum
Tantalum
Monel
Monel
Gold
Gold
Version as diaphragm seal 1)

E)
E)
E)

Process connection
Female thread -18 NPT with flange connection
Sealing screw opposite process connection
- Mounting thread M10 to DIN 19 213

1
6
7

A
B
C
E
H
L
Y

- Mounting thread 7/16-20 UNF to EN 61518


Vent on side of process flange 2)
- Mounting thread M10 to DIN 19 213

- Mounting thread 7/16-20 UNF to EN 61518

Non-wetted parts materials


Process flange screws Electronics housing
Stainless steel
Stainless steel

Die-cast aluminium
Stainless steel precision
casting

Design
Standard design
International version, English label
inscriptions, documentation in 5 languages
on CD
Explosion protection
without
with CENELEC, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 3)
- "Intrinsic safety and explosion-proof enclosure
(EEx ia + EEx d)" 4)
- "n (zone 2)" (planned)
- "Intrinsic safety, explosion-proof enclosure and
dust explosion protection (EEx ia + EEx d +
zone 1D/2D)" 4)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 3)
Electrical connection / cable inlet
Screwed gland M20x1.5
Screwed gland -14 NPT
PROFIBUS plug M12 incl. mating connector 5)

2
3

1
2

A
B
D
P
E
R

NC
B
C
F

Siemens FI 01 2005

2/65

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for absolute pressure
(from differential pressure series)

Further designs

Order code

Further designs

Please add "-Z" to Order No. and specify Order code.

Please add "-Z" to Order No. and specify Order code.

Pressure transmitter with mounting bracket made of:


Steel
A01
Stainless steel
A02

Additional data

O-rings for process flanges


(instead of FPM (Viton))
PTFE (Teflon)
FEP (with silicone core, approved for food)
FFPM (Kalrez, compound 4079)
NBR (Buna N)

A20
A21
A22
A23

Sealing screws
-18 NPT, with valve in material of process flanges

A40

Rating plate inscription


(instead of German)
English
French
Spanish
Italian

B11
B12
B13
B14

English rating plate


Pressure units in inH2O or psi

B21

Manufacturer's test certificate M


to DIN 55.350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10 204-3.1B

C12

Factory certificate
to EN 10.204-2.2

C14

Acid gas version to NACE


(only together with seal diaphragm made of Hastelloy
and process flange screws made of stainless steel)

D07

Type of protection IP68


(not together with PROFIBUS plug M12)

D12

Digital indicator along side the input keys


(only together with the devices 7MF4334-...0.2-.A.6 or
-.A.7-Z, Y21)

D27

Use on zone 1D / 2D
(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

Oxygen application
(max. 160 bar (2320 psi) with oxygen measurement
and inert liquid)

E10

Interchanging of process connection side

H01

Vent on side for gas measurements

H02

Process flange
Hastelloy
Monel
Stainless steel with PVDF insert
Max. PN 10 (MWP 145 psi)
Max. temperature of medium 90 C (194 F)

K01
K02
K04

2/66

Siemens FI 01 2005

Order code

Measuring point number/identification


max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Setting of pressure indicator in pressure units


specify in plain text
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C
Preset bus address

Y21

Y25

specify in plain text (standard setting: 126)


Y25: ...........................................
Only the settings for "Y21" and "Y25" can be made in the factory

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for differential pressure and flow

Technical specifications
SITRANS P pressure transmitters, DS III PA series for differential
pressure and flow
Input
Measured variable

Differential pressure and flow

Nominal measuring range

Max. working pressure

PN 32 (MWP 464 psi)


- 20 mbar (0.29 psi)

32 bar (464 psi)

Weight (without options)

4.5 kg ( 9.9 lb)

Wetted parts materials


Seal diaphragm

Stainless steel, mat. No.


1.4404/316L,
Hastelloy C276, mat. No. 2.4819,
Monel, mat. No. 2.4360, tantalum
or gold

Measuring cell filling

Silicone oil or inert filling liquid


(max. 160 bar (2320 psi) with oxygen measurement)

Process connection

Female thread 1/4-18 NPT and


flange connection to DIN 19213
with mounting thread M10 or
7/ -20 UNF to EN 61518
16
Supplied through bus

PN 160 (MWP 2320 psi)


- 60 mbar (0.87 psi)

160 bar (2320 psi)

- 250 mbar (3.63 psi)

160 bar (2320 psi)

- 600 mbar (8.7 psi)

160 bar (2320 psi)

- 1600 mbar (23.3 psi)

160 bar (2320 psi)

Power supply UH

- 5 bar (72.5 psi)

160 bar (2320 psi)

Separate 24 V power supply neces- No


sary

- 30 bar (435 psi)

160 bar (2320 psi)

Bus voltage

PN 400 (MWP 6092 psi)

Not Ex

9 ... 32 V

With intrinsically-safe operation

9 ... 24 V

- 250 mbar (3.63 psi)

420 bar (6092 psi)

- 600 mbar (8.7 psi)

420 bar (6092 psi)

Current consumption

- 1600 mbar (23.3 psi)

420 bar (6092 psi)

Basic current (max.)

12.5 mA

- 5 bar (72.5 psi)

420 bar (6092 psi)

Max. current in event of fault

15.5 mA

- 30 bar (435 psi)

420 bar (6092 psi)

Certificates and approvals

Lower measuring limit


Measuring cell with silicone oil filling

-100% of nominal measuring


range (-33% with nominal measuring range 30 bar (435 psi)) or
30 mbar (0.435 psi) absolute

Upper measuring limit

100% of nominal measuring


range (max. 160 bar (2320 psi)
with oxygen measurement and
inert filling liquid)

Output

Digital PROFIBUS PA signal

Physical bus

IEC 61158-2

Classification according to pressure


equipment directive
(DRGL 97/23/EC)
- PN 32/160 (MWP 464/2320)

For gases of fluid group 1 and


liquids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)

- PN 420 (MWP 6092)

For gases of fluid group 1 and


liquids of fluid group 1; complies
with basic safety requirements of
article 3, paragraph 1 (appendix
1); assigned to category III, conformity evaluation module H by
the TV Nord

Measuring accuracy
Reference conditions

Increasing characteristic
Start-of-scale value 0 bar
Stainless steel seal diaphragm
Silicone oil filling
Room temperature (25 C (77 F))

Error in measurement (including


hysteresis and repeatability)
- Linear characteristic

0.075%

- Square-root characteristic, flow


> 50 %

0.1%

- Square-root characteristic, flow


25 ... 50%

0.2%

Explosion protection
Intrinsic safety "i"

With -10 ... +60 C (14 ... 140 F)

0.3% (Twice the value with 20mbar (0.29 psi) nominal measuring range)

With -40 ... -10 C and


+60 C ... +85 C
(-40 ... +14 and 140 ... 185 F)

0.25% / 10 K ( 0.25% / 18 F)
(Twice the value with 20 mbar
(0.29 psi) nominal measuring
range)

Rated conditions

Ex II 1/2 G EEx ia/ib IIB/IIC T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +70 C (-40 ... +158 F)
temperature class T5;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To a certified intrinsically-safe circuit with maximum values:


FISCO supply unit:
Uo = 17.5 V, Io = 380 mA,
Po = 5.32 W
Linear barrier:
Uo = 24 V, Io = 250 mA,
Po = 1.2 W

- Effective internal inductance/


capacitance

Li = 7 H, Ci = 1.1 nF

Explosion-proof "d"
IP65

Process temperature
Measuring cell with silicone oil filling

-40 ... +100 C (-40 ... +212 F)


-20 ... +60 C (-4 ... +140 F) in
conjunction with dust explosion
protection

PTB 99 ATEX 2122

- Identification

Influence of ambient temperature

Degree of protection (to EN 60529)

Design

PTB 99 ATEX 1160

- Identification

Ex II 1/2 G EEx d IIC T4/T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To circuits with values:


UH = 9 ... 32 V DC

Siemens FI 01 2005

2/67

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for differential pressure and flow
Dust explosion protection for
zone 20

PTB 01 ATEX 2055

- Identification

Dust explosion protection for


zone 21/22

Ex II 1 D IP65 T 120 C
Ex II 1/2 D IP65 T 120 C

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)

- Max.surface temperature

120 C (248 F)

- Connection

To a certified intrinsically-safe circuit with maximum values:


FISCO supply unit:
Uo = 17.5 V, Io = 380 mA,
Po = 5.32 W
Linear barrier:
Uo = 24 V, Io = 250 mA,
Po = 1.2 W

- Effective internal inductance/capacitance

Li = 7 H, Ci = 1.1 nF

PTB 01 ATEX 2055

- Identification

Ex II 2 D IP65 T 120 C

- Connection

To circuits with values:


UH = 9 ... 32 V DC; Pmax = 1.2 W

Type of protection "n" (zone 2)

Planned

Explosion protection to FM

Certificate of Compliance
3008490

- Identification (XP/DIP) or (IS);


(NI)

CL I, DIV 1, GP ABCD T4...T6;


CL II, DIV 1, GP EFG; CL III; CL I,
ZN 0/1 AEx ia IIC T4...T6; CL I,
DIV 2, GP ABCD T4...T6; CL II,
DIV 2, GP FG; CL III

Explosion protection to CSA

Certificate of Compliance
1153651

- Identification

CL I, GP ABCD; CL II, GP EFG;


CL III; Enclosure Type 4X, CL I,
DIV 2, GP ABCD; CL II, DIV 2,
GP FG; CL III; Enclosure Type 4X

Dimensional drawings
approx. 30 (1.2)

50
(1.97)

3
approx. 261 (10.3)

198 (7.8)

1
+

Space for rotation


of housing

10
8

7
11

72 (2.83)
105 (4.1)
1
2
3

4
5
6
7
8
9
10
11

Process connection: -18 NPT (EN 61518)


Blanking plug
Electrical connection:
- screwed gland M20x1,5 4),
- screwed gland -14 NPT or
- PROFIBUS plug M12 3) 4)
Terminal side
Electronic side, digital display (longer overall length for cover with window)
Protective cover over keys
Mounting bracket (option)
Sealing screw with valve (option)
Screw cover safety bracket (only for explosion-proof enclosure,
not shown in the drawing)
Lateral venting for liquid measurement
Lateral venting for gas measurement (suffix H02)

52 (2.05)

68 (2.7)
120 (4.7)

1)
2)
3)
4)

Allow approx. 20 mm (0.79 inch) thread length in addition


92 mm (3.62 inch) for minimum distance to permit rotation with indicator
Not with type of protection "explosion-proof enclosure"
Not with type of protection "FM + CSA"

SITRANS P pressure transmitters, DS III PA series for differential pressure and flow, dimensional drawing, dimensions in mm (inch)

2/68

Siemens FI 01 2005

96 (3.8)

117 (4.6)

80
(3.15)
5 1)

1)

69 (2.7)
77 (3) 2)

100 (3.94)

50
(1.97)

138 (5.4)

20
(0.8)

15
(0.6)

134 (5.27)

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for differential pressure and flow

138 (5.4)

approx.
85 (3.35)4)

Space for rotation


of housing

77 (3)2)

4 1)

5 1)

100 (3.94)

50
(1.97)

diam. 80
(3.15)

20
(0.8)

50
(1.97)

69 (2.7)

approx 30 (1.18)6)

approx. 217 (8.54)5)

15
(0.6)

8
1

67 (2.64)3)

1
2
3

4
5
6
7
8
9

Process connection -18 NPT (EN 61 518)


Blanking plug
Electrical connection:
screwed gland M20x1.5,
screwed gland -14 NPT or
PROFIBUS plug M12
Terminal side
Electronics side, digital display (longer overall length for cover with window)
Protective cover over keys
Mounting bracket (option)
Sealing screw with valve (option)
Screw cover safety bracket (only for explosion-proof enclosure,
not shown in the drawing)

approx.
84,6 (3.33)

1)
2)
3)
4)
5)
6)

Allow approx. 20 mm (0.79 inch) thread length in addition


92 mm (3.6 inch) for minimum distance to permit rotation
without indicator
74 mm (2.9 inch) for PN 420 (MWP 6092 psi)
91 mm (3.6 inch) for PN 420 (MWP 6092 psi)
219 mm (8.62 inch) for PN 420 (MWP 6092 psi)
Approx. 45 mm (1.77 inch) for Pg 13.5 with adapter

SITRANS P pressure transmitters, DS III PA series for differential pressure and flow, with process covers for vertical differential pressure lines, dimensional drawing, dimensions in mm (inch)

SITRANS P pressure transmitters, DS III PA series for differential pressure and flow, with process covers for vertical differential pressure lines

Siemens FI 01 2005

2/69

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for differential pressure and flow

115 (4.5)

183 (7.2)

77
(3.0)

193 (7.6)

FIELD
TERMINALS
3

1
2
3
4
5
6
7
8

Process connection, -18 NPT (EN 61 518)


Terminal side, analog indicator (optional)
External digital indicator (optional)
Sealing plug
Fixing screw
Blanking plug
Protective cover for keys
Electrical connection

SITRANS P pressure transmitters, DS III PA series for differential pressure and flow, with digital indicator beside control keys, dimensional drawing,
dimensions in mm (inch)

SITRANS P pressure transmitters, DS III PA series for differential pressure and flow, with digital indicator beside control keys

2/70

Siemens FI 01 2005

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for differential pressure and flow
Selection and Ordering data

Order No.

Selection and Ordering data

Order No.

SITRANS P pressure transmitters


for differential pressure and flow

7MF 4 4 3 4 -

SITRANS P pressure transmitters


for differential pressure and flow

7MF 4 4 3 4 -

DS III PA series, PN 32 / 160 (MWP 464 / 2320 psi) 7 7 7 7 7 - 7 7 7 7

DS III PA series, PN 32 / 160 (MWP 464 / 2320 psi) 7 7 7 7 7 - 7 7 7 7

Measuring cell filling


Silicone oil
Inert liquid

Display
without (digital display hidden)
with visible digital indicator
with customer-specific digital indicator (setting
as specified, Order code "Y21" required)

Measuring cell cleaning


Standard
Grease-free

1
3

Rated measuring range


PN 32 (MWP 464 psi)
20 mbar 1)
(0.29 psi)

PN 160 (MWP 2320 psi)


60 mbar
250 mbar
600 mbar
1600 mbar
5000 mbar
30 bar

C
D
E
F
G
H

(0.87 psi)
(3.63 psi)
(8.70 psi)
(23.2 psi)
(72.5 psi)
(435 psi)

Included in delivery of the device:


Brief instructions (Leporello)
CD-ROM with detailed documentation
Sealing plug(s) or sealing screw(s) for the process flanges(s)
1) Not suitable for connection of remote seal
2) Only together with max. spans 250, 1600, 5000 and 30000 mbar
(3.63, 23.2, 72.5 and 435 psi).
3) Without cable gland, with blanking plug
4) With enclosed cable gland EEx ia and blanking plug
5) Not together with types of protection "Explosion-proof" and "Intrinsic safety
und explosion-proof"

Wetted parts materials


(stainless steel process flanges)
Seal diaphragm
Parts of measuring cell
Stainless steel
Stainless steel
Hastelloy
Stainless steel
Hastelloy
Hastelloy
Tantalum 2)
Tantalum
Monel 2)
Monel
Gold 2)
Gold
Version as diaphragm seal
Process connection
Female thread -18 NPT with flange connection
Sealing screw opposite process connection
- Mounting thread M10 to DIN 19 213

1
6
7

A
B
C
E
H
L
Y

- Mounting thread 7/16-20 UNF to EN 61518


Venting on side of process flanges 2)
- Mounting thread M10 to DIN 19 213

- Mounting thread 7/16-20 UNF to EN 61518

Non-wetted parts materials


Process flange screws Electronics housing
Stainless steel
Stainless steel

Die-cast aluminium
Stainless steel precision
casting

Design
Standard design
International version, English label inscriptions,
documentation in 5 languages on CD
Explosion protection
without
with CENELEC, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 3)
- "Intrinsic safety and explosion-proof enclosure
(EEx ia + EEx d)" 4)
- "n (zone 2)" (planned)
- "Intrinsic safety, explosion-proof enclosure and
dust explosion protection (EEx ia + EEx d +
zone 1D/2D)" 4)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 3)
Electrical connection / cable inlet
Screwed gland M20x1.5
Screwed gland -14 NPT
PROFIBUS plug M12 incl. mating connector 5)

2
3

1
2

A
B
D
P
E
R

NC
B
C
F

Siemens FI 01 2005

2/71

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for differential pressure and flow

Further designs

Order code

Further designs

Please add "-Z" to Order No. and specify Order code.

Please add "-Z" to Order No. and specify Order code.

Pressure transmitter with mounting bracket made of:


Steel
A01
Stainless steel
A02

Additional data

O-rings for process flanges


(instead of FPM (Viton))
PTFE (Teflon)
FEP (with silicone core, approved for food)
FFPM (Kalrez, compound 4079)
NBR (Buna N)

A20
A21
A22
A23

Sealing screws
-18 NPT, with valve in material of process flanges

A40

Rating plate inscription


(instead of German)
English
French
Spanish
Italian

B11
B12
B13
B14

English rating plate


Pressure units in inH2O or psi

B21

Manufacturer's test certificate M


to DIN 55.350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10 204-3.1B

C12

Factory certificate
to EN 10.204-2.2

C14

Acid gas version to NACE


(only together with seal diaphragm made of Hastelloy
and process flange screws made of stainless steel)

D07

Type of protection IP68


(not together with PROFIBUS plug M12)

D12

Digital indicator along side the input keys


(only together with the devices 7MF4434-....0-.A.6 or
-.A.7-Z, Y21)

D27

Use on zone 1D / 2D
(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

Overfilling safety device for flammable and


non-flammable liquids
(max. PN 32 (MVWP 464 psi), basic device with type of
protection "Intrinsic safety (EEx ia)")

E08

Oxygen application
(max. 160 bar (2320 psi) with oxygen measurement
and inert liquid)

E10

Interchanging of process connection side

H01

Vent on side for gas measurements

H02

Stainless steel process flanges for vertical


differential pressure lines
(not together with K01, K02 and K04) 1)

H03

Process flange
Hastelloy
Monel
Stainless steel with PVDF insert
Max. PN 10 (MWP 145 psi)
Max. temperature of medium 90 C (194 F)

2/72

Siemens FI 01 2005

K01
K02
K04

Order code

Measuring point number/identification


max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Setting of pressure indicator in pressure units


specify in plain text
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C

Y21

Preset bus address


specify in plain text (standard setting: 126)
Y25: ...........................................

Y25

Only the settings for "Y21" and "Y25" can be made in the factory
1) Not suitable for connection of remote seal

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for differential pressure and flow
Selection and Ordering data

Order No.

Further designs

SITRANS P pressure transmitters


for differential pressure and flow

7MF 4 5 3 4 -

Please add "-Z" to Order No. and specify Order code.

DS III PA series, PN 420 (MWP 6092 psi)

1 7777 - 7777

Pressure transmitter with mounting bracket made of:


Steel
A01
Stainless steel
A02

Rated measuring range


250 mbar
(3.63 psi)
600 mbar
(8.70 psi)
1600 mbar
(23.2 psi)
5 bar
(72.5 psi)
30 bar
(435 psi)

D
E
F
G
H

Wetted parts materials


(stainless steel process flanges)
Seal diaphragm
Parts of measuring cell
Stainless steel
Hastelloy
Gold 1)

Stainless steel
Stainless steel
Gold

Process connection
Female thread -18 NPT with flange connection
Sealing screw opposite process connection
- Mounting thread M12 to DIN 19 213
- Mounting thread 7/16-20 UNF to EN 61518
Venting on side of process flanges
- Mounting thread M12 to DIN 19 213
- Mounting thread 7/16-20 UNF to EN 61518

A
B
L

Die-cast aluminium
Stainless steel precision
casting

O-rings for process flanges


(instead of FPM (Viton))
PTFE (Teflon)
FEP (with silicone core, approved for food)
FFPM (Kalrez, compound 4079)
NBR (Buna N)

A20
A21
A22
A23

Sealing screws
-18 NPT, with valve in material of process flanges

A40

Rating plate inscription


(instead of German)
English
French
Spanish
Italian

B11
B12
B13
B14

English rating plate


Pressure units in inH2O or psi

B21

Manufacturer's test certificate M


to DIN 55.350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10 204-3.1B

C12

Factory certificate
to EN 10.204-2.2

C14

Acid gas version to NACE


(only together with seal diaphragm made of Hastelloy
and process flange screws made of stainless steel)

D07

Type of protection IP68


(not together with PROFIBUS plug M12)

D12

Digital indicator along side the input keys


(only together with the devices 7MF4534-...0.2-.A.6 or
-.A.7-Z, Y21)

D27

Use on zone 1D / 2D
(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

Interchanging of process connection side

H01

Stainless steel process flanges for vertical


differential pressure lines

H03

Non-wetted parts materials


Process flange screws Electronics housing
Stainless steel
Stainless steel

Order code

2
3

Design
Standard design
International version, English label inscriptions,
documentation in 5 languages on CD
Explosion protection
without
with CENELEC, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 2)
- "Intrinsic safety and explosion-proof enclosure
(EEx ia + EEx d)" 3)
- "n (zone 2)" (planned)
- "Intrinsic safety, explosion-proof enclosure and
dust explosion protection (EEx ia + EEx d +
zone 1D/2D)" 3)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 2)
max. PN 360
Electrical connection / cable inlet
Screwed gland M20x1.5
Screwed gland -14 NPT
PROFIBUS plug M12 incl. mating connector 4)
Display
without (digital display hidden)
with visible digital indicator
with customer-specific digital indicator (setting
as specified, Order code "Y21" required)

1
2

A
B
D
P
E
R

NC

B
C
F
1
6
7

Included in delivery of the device:


Brief instructions (Leporello)
CD-ROM with detailed documentation
Sealing plug(s) or sealing screw(s) for the process flanges(s)
1)
2)
3)
4)

Not together with max. span 600 mbar


Without cable gland, with blanking plug
With enclosed cable gland EEx ia and blanking plug
Not together with types of protection "Explosion-proof" and "Intrinsic safety
und explosion-proof"

Siemens FI 01 2005

2/73

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA series for differential pressure and flow

Further designs

Order code

Please add "-Z" to Order No. and specify Order code.


Additional data
Measuring point number/identification
max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Setting of pressure indicator in pressure units


specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C

Y21

Preset bus address


specify in plain text (standard setting: 126)
Y25: ...........................................

Y25

Only the settings for "Y21" and "Y25" can be made in the factory

2/74

Siemens FI 01 2005

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA (PROFIBUS) for level

Technical specifications

Design

SITRANS P pressure transmitters, DS III PA series for level


Input

Weight
To DIN (pressure transmitter with
mounting flange, without tube)

11 ... 13 kg (24.2 ... 28.7 lb)


11 ... 18 kg (24.2 ... 39.2 lb)

Measured variable

Level

Rated measuring range

Max. working pressure

To ASME (pressure transmitter with


mounting flange, without tube)

250 mbar (3.63 psi)

See "Mounting flange"

Wetted parts materials

600 mbar (8.7 psi)

High-pressure side:

1600 mbar (23.2 psi)

Seal diaphragm of mounting flange

-100% of max. span or


30 mbar (0.435 psi) absolute,
depending on mounting flange

Stainless steel 316L,


Monel 400, mat. No. 2.4360,
Hastelloy B2, mat. No. 2.4617,
Hastelloy C276, mat. No. 2.4819,
Hastelloy C4, mat. No. 2.4610,
tantalum, PTFE, ECTFE

Measuring cell filling

Silicone oil

Upper measuring limit

100% of max. span

Process connection

Output

Digital PROFIBUS PA signal

High-pressure side

Flange to DIN and ANSI

IEC 61158-2

Low-pressure side

Female thread -18 NPT and


flange connection to DIN 19213
with mounting thread M10 or
7/ -20 UNF to EN 61518
16

Power supply UH

Supplied through bus

5000 mbar (72.5 psi)


Lower measuring limit
Measuring cell with silicone oil filling

Physical bus
Measuring accuracy
Reference conditions

Increasing characteristic
Start-of-scale value 0 bar
Stainless steel seal diaphragm
Mounting flange without tube
Silicone oil filling
Room temperature (25 C (77 F))

Error in measurement (including


hysteresis and repeatability)
- Linear characteristic

0.15%

Influence of ambient temperature


With -10 ... +60 C (14 ... 140 F)
- 250-mbar (3.63 psi) measuring
cell
- 600-mbar (8.7 psi) measuring
cell
- 1,600 and 5,000 mbar (23.2 and
72.5 psi) measuring cells

0.7%

- 600-mbar (8.7 psi) measuring


cell
- 1,600 and 5,000 mbar (23.2 and
72.5 psi) measuring cells

Bus voltage
Not Ex

9 ... 32 V

With intrinsically-safe operation

9 ... 24 V

Current consumption
Basic current (max.)

12.5 mA

Max. current in event of fault

15.5 mA

Certificates and approvals


0.5%
0.45%

With -40 ... -10 C and


+60 C ... +85 C
(-40 ... +14 and 140 ... 185 F)
- 250-mbar (3.63 psi) measuring
cell

Separate 24 V power supply neces- No


sary

Classification according to pressure


equipment directive
(DRGL 97/23/EC)

Explosion protection
Intrinsic safety "i"
- Identification

Ex II 1/2 G EEx ia/ib IIB/IIC T6

0.3% / 10 K ( 0.4% / 18 F)

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +70 C (-40 ... +158 F)
temperature class T5;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To a certified intrinsically-safe circuit with maximum values:


FISCO supply unit:
Uo = 17.5 V, Io = 380 mA,
Po = 5.32 W
Linear barrier:
Uo = 24 V, Io = 250 mA,
Po = 1.2 W

- Effective internal inductance/capacitance

Li = 7 H, Ci = 1.1 nF

0.27% / 10 K ( 0.4% / 18 F)
Note
Note the assignment of the max.
permissible operating temperature to the max. permissible operating pressure of the respective
flange connection!

Degree of protection (to EN 60529)

IP65

Temperature of medium
Measuring cell with silicone oil filling

- Low-pressure side

PTB 99 ATEX 2122

0.4% / 10 K ( 0.4% / 18 F)

Rated conditions

- High-pressure side

For gases of fluid group 1 and


liquids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)

pabs 1bar: -40 ... +175 C


(-40 ... +347 F)
pabs < 1bar:-40 ... +80 C
(-40 ... +176 F)
-40 ... +100 C (-40 ... +212 F)
-20 ... +60 C (-4 ... +140 F) in
conjunction with dust explosion
protection

Explosion-proof "d"

PTB 99 ATEX 1160

- Identification

Ex II 1/2 G EEx d IIC T4/T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To circuits with values:


UH = 9 ... 32 V DC

Siemens FI 01 2005

2/75

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA (PROFIBUS) for level

Dust explosion protection for


zone 20

PTB 01 ATEX 2055

- Identification

Ex II 1 D IP65 T 120 C
Ex II 1/2 D IP65 T 120 C

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)

- Max.surface temperature

120 C (248 F)

- Connection

To a certified intrinsically-safe circuit with maximum values:


FISCO supply unit:
Uo = 17.5 V, Io = 380 mA,
Po = 5.32 W
Linear barrier:
Uo = 24 V, Io = 250 mA,
Po = 1.2 W

- Effective internal inductance/capacitance


Dust explosion protection for zone
21/22

L i = 7 H, Ci = 1.1 nF
PTB 01 ATEX 2055

- Identification

Ex II 2 D IP65 T 120 C

- Connection

To circuits with values:


UH = 9 ... 32 V DC; Pmax = 1.2 W

Type of protection "n" (zone 2)

Planned

Explosion protection to FM

Certificate of Compliance
3008490

- Identification (XP/DIP) or (IS);


(NI)

Explosion protection to CSA


- Identification

2/76

Siemens FI 01 2005

CL I, DIV 1, GP ABCD T4...T6;


CL II, DIV 1, GP EFG; CL III; CL I,
ZN 0/1 AEx ia IIC T4...T6; CL I,
DIV 2, GP ABCD T4...T6; CL II,
DIV 2, GP FG; CL III
Certificate of Compliance
1153651
CL I, GP ABCD; CL II, GP EFG;
CL III; Enclosure Type 4X, CL I,
DIV 2, GP ABCD; CL II, DIV 2,
GP FG; CL III; Enclosure Type 4X

Mounting flange
Nom. diam.

Nom. press.

To EN 1092-1
- DN 80

PN 40

- DN 100

PN 16
PN 40

To ASME B16.5
- 3 inch

class 150
class 300

- 4 inch

class 150
class 300

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA (PROFIBUS) for level

Dimensional drawings

ca. 30 (1.18)

185
100 (3.94)

138 (5.4)
69 (2.72)

50
(1.97)

15
(0.6)

51)

77 (3)4)

165 (6.5)

54 (2.1)

d5
d4

108 (4.25)
Space for rotation
of housing

nxd 2
b
f
1
2
3

4
5
6
8
9
1)
2)
3)
4)

Process connection of low pressure side -18 NPT (EN 61518)


Blanking plug
Electrical connection:
- screwed connection M20x1,5 3),
- screwed connection -14 NPT or
- PROFIBUS plug M12 2) 3)
Terminal side
Electronics side, digital display (longer overall length for cover with window)
Protective cover over keys
Sealing screw with valve (option)
Screw cover safety bracket (only for "explosion-proof enclosure",
not shown in the drawing)

51)

41)

Allow approx. 20 mm (0.79 inch) thread length in addition


Not with type of protection "Explosion-proof enclosure"
Not with type of protection "FM + CSA [is + xp]"
92 mm (3.62 inch) for minimum distance to permit rotation with indicator

SITRANS P pressure transmitters, DS III PA series for level, including mounting flange, dimensions in mm (inch)

Connection to EN 1092-1
Nom. diam.

Nom. press.

d2

d4

d5

dM

DN 80

PN 40

DN 100

PN 40

20

220

115

18

158

94

89

180

PN 40

24

235

115

22

162

94

89

190

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

24

200

90

18

138

76

72 1)

160

0, 50, 100,
150 or 200

Connection to ASME B16.5


Nom. diam.
3 inch

4 inch

Nom. press.

lb/sq.in.

inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm)

150

0.94
(23.8)

7.5
(190.5)

0.75
(19.0)

5
(127)

3
(76)

2.81 1)
(72)

0.06
(1.6)

6
(152.4)

300

1.12
(28.6)

8.25
(209.5)

0.87
(22.2)

5
(127)

3
(76)

2.81 1)
(72)

0.06
(1.6)

6.69
(168.3)

150

0.94
(23.8)

9
(228.5)

0.75
(19.0)

6,19
(157.2)

3.69
(94)

3.5
(89)

0.06
(1.6)

7.5
(190.5)

300

1.25
(31.7)

10
(254)

0.87
(22.2)

6,19
(157.2)

3.69
(94)

3.5
(89)

0.06
(1.6)

7.88
(200)

d: Internal diameter of gasket to DIN 2690


dM: Effective diaphragm diameter

d2

d4

d5

1)

dM

L
inch (mm)
0, 2, 3.94,
5.94 or 7.87
(0, 50, 100,
150 or 200)

89 mm = 3 inch with tube length L = 0.

Siemens FI 01 2005

2/77

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA (PROFIBUS) for level

Selection and Ordering data

Order No.

Further designs

SITRANS P pressure transmitters


for level

7MF 4 6 3 4 -

Please add "-Z" to Order No. and specify Order code.

DS III PA series

1 7 Y77 - 7777

Rated measuring range


250 mbar
(3.63 psi)
600 mbar
(8.70 psi)
1600 mbar
(23.2 psi)
5 bar
(72.5 psi)
Process connection of low-pressure side
Female thread -18 NPT with flange connection
Mounting thread M10 to DIN 19 213
Mounting thread 7/16-20 UNF to EN 61518

D
E
F
G

0
2

Non-wetted parts materials


Process flange screws Electronics housing
Stainless steel
Stainless steel

Die-cast aluminium
Stainless steel precision
casting

2
3

Design
Standard design
International version, English label inscriptions,
documentation in 5 languages on CD
Explosion protection
without
with CENELEC, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 1)
- "Intrinsic safety and explosion-proof enclosure
(EEx ia + EEx d)" 2)
- "n (zone 2)"
- "Intrinsic safety, explosion-proof enclosure and
dust explosion protection (EEx ia + EEx d +
zone 1D/2D)" 2)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 1)
Electrical connection / cable inlet
Screwed gland M20x1.5
Screwed gland -14 NPT
PROFIBUS plug M12 incl. mating connector 3)
Display
without (digital display hidden)
with visible digital indicator
with customer-specific digital indicator (setting
as specified, Order code "Y21" required)

1
2

A
B
D
P
E
R

NC
B
C
F
1
6
7

Order code

O-rings for process flanges on low-pressure side


(instead of FPM (Viton))
PTFE (Teflon)
FEP (with silicone core, approved for food)
FFPM (Kalrez, compound 4079)
NBR (Buna N)

A20
A21
A22
A23

Sealing screws
-18 NPT, with valve in material of process flanges

A40

Rating plate inscription


(instead of German)
English
French
Spanish
Italian

B11
B12
B13
B14

English rating plate


Pressure units in inH2O or psi

B21

Manufacturer's test certificate M


to DIN 55.350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10 204-3.1B

C12

Factory certificate
to EN 10.204-2.2

C14

Type of protection IP68


(not together with PROFIBUS plug M12)

D12

Use on zone 1D / 2D
(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

Overfilling safety device for flammable and


non-flammable liquids
(max. PN 32 (MWP 464 psi), basic device with type of
protection "Intrinsic safety (EEx ia)")

E08

Interchanging of process connection side

H01

Additional data
Measuring point number/identification
max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Ordering information:
1st order item: Pressure transmitter 7MF4634-...
2nd order item: Mounting flange 7MF4912-...

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Example of ordering:
Item line 1:
7MF4634-1EY20-1AA1
Item line 2:
7MF4912-3GE01

Setting of pressure indicator in pressure units


specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C

Y21

Preset bus address


specify in plain text (standard setting: 126)
Y25: ...........................................

Y25

Included in delivery of the device:


Brief instructions (Leporello)
CD-ROM with detailed documentation
Sealing plug(s) or sealing screw(s) for the process flanges(s)
1) Without cable gland, with blanking plug
2) With enclosed cable gland EEx ia and blanking plug
3) Not together with types of protection "Explosion-proof" and "Intrinsic safety
und explosion-proof"

Only the settings for "Y21" and "Y25" can be made in the factory

2/78

Siemens FI 01 2005

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III PA (PROFIBUS) for level
Selection and Ordering data

Order No.

Further designs

Mounting flange

7MF 4 9 1 2 -

Please add "-Z" to Order No. and specify Order code.

directly fitted to pressure transmitter


SITRANS P (converter part) for level,
for DS III series

3 7777

Spark arrestor
for mounting on zone 0 (including documentation)

A01

Manufacturer's test certificate M


to DIN 55.350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10 204-3.1B

C12

Vacuum-proof design
(for use in low-pressure range)

V04

Calculation of span of associated pressure


transmitter
(enclose filled-in questionnaire with order)
Note:
Suffix "Y01" required with pressure transmitter

Y05

Connection to EN 1092-1
Nom. diam.
Nom. press.
DN 80
PN 40
DN 100
PN 16
PN 40
Connection to ASME B16.5
Nom. diam.
Nom. press.
3 inch
Class 150
Class 300
4 inch
Class 150
Class 300
Other version
Add Order code and plain text:
Nominal diameter: ...; Nominal pressure: ...

D
G
H

Q
R
T
U
Z

J1Y

Wetted parts materials


Stainless steel 316L 1)
- Coated with PFA
- Coated with PTFE
- Coated with ECTFE

A
D
E0
F

Monel 400, mat. No. 2.4360


Hastelloy B2, mat. No. 2.4617
Hastelloy C276, mat. No. 2.4819
Hastelloy C4, mat. No. 2.4610
Tantalum

G
H
J
U
K

Other version
Add Order code and plain text:
Wetted parts materials: ...
Sealing face, see "Technical data"

Tube length
Without
50 mm
(1.97 inch)
100 mm
(3.94 inch)
150 mm
(5.90 inch)
200 mm
(7.87 inch)
Other version:
Add Order code and plain text:
Tube length: ...
Filling liquid
Silicone oil M5
Silicone oil M50
High-temperature oil
Halocarbon oil (for O2 measurements)
Vegetable oil
Glycerin / water2)
Other version
Add Order code and plain text:
Filling liquid: ...

777

Order code

K1Y

0
1
2
3
4
9

L1Y

1
2
3
4
5
6
9

M1 Y

1) For vacuum on request


2) Not suitable for use in low-pressure range

Siemens FI 01 2005

2/79

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series (Foundation Fieldbus)

Overview

SITRANS P pressure transmitters of the DS III FF series are digital pressure transmitters featuring extensive user-friendliness
and high accuracy. Parameterization is performed using input
keys or through the Foundation Fieldbus Interface.
Extensive functionality enables the pressure transmitter to be
precisely adapted to the plants requirements. Operation is very
simple in spite of the numerous setting options.
Transmitters with type of protection "Intrinsic safety" and "Explosion-proof" (planned) may be installed within potentially explosive atmospheres (zone 1) or in zone 0. The transmitters are provided with an EC type examination certificate and comply with
the corresponding harmonized European standards (ATEX).
The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of
highly viscous substances.
Various versions of the DS III FF pressure transmitters are available for measuring:
Pressure
Absolute pressure
For differential pressure transmitters
Level
Volume
Volume flow
Mass flow

SITRANS P pressure transmitters, DS III FF series, can be used


in industrial areas with extreme chemical and mechanical loads.
Electromagnetic compatibility in the range 10 kHz to 1 GHz
makes the DS III FF pressure transmitters suitable for locations
with high electromagnetic emissions.
Transmitters with type of protection "Intrinsic safety" and "Explosion-proof" (planned) may be installed within potentially explosive atmospheres (zone 1) or in zone 0. The pressure transmitters are provided with an EC type examination certificate and
comply with the corresponding harmonized European standards
of the CENELEC.
Pressure transmitters with the type of protection "Intrinsic safety"
for use in zone 0 may be operated with power supply units of category "ia" and "ib".
The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of
highly viscous substances.
Pressure transmitters for pressure
Measured variable: Pressure of aggressive and non-aggressive
gases, vapors and liquids.
Measured spans: 0.01 ... 400 bar (0.145 ... 5802 psi)
Pressure transmitters for absolute pressure
Measured variable: Absolute pressure of aggressive and nonaggressive gases, vapors and liquids.

Benefits
High quality and long life
High reliability even under extreme chemical and mechanical
loads
For aggressive and non-aggressive gases, vapors and liquids
Extensive diagnosis and simulation functions
Separate replacement of measuring cell and electronics without recalibration
Minimum conformity error
Small long-term drift
Wetted parts made of high-grade materials (stainless steel,
Hastelloy, gold, Monel, tantalum)
Choice of several nominal measuring ranges
High measuring accuracy
Parameterization using input keys and Foundation Fieldbus

2/80

Application

Siemens FI 01 2005

Measured spans: 8.3 mbar ... 100 bar (0.12 ... 1450 psi)
There are two series:
Pressure series
Differential pressure series
Pressure transmitters for differential pressure and flow
Measured variables:
Differential pressure
Small positive or negative pressure
Flow q ~ p (together with a primary differential pressure device)
Nominal measuring ranges: 1 mbar ... 30 bar
(0.0145 ... 435 psi)

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series (Foundation Fieldbus)
Pressure transmitters for level
Measured variable: Level of aggressive and non-aggressive liquids in open and closed vessels.
Nominal measuring ranges: 25 mbar ... 5 bar (0.363 ... 72.5 psi)
Nominal diameter of the mounting flange:
DN 80 or DN 100
3 inch or 4 inch

cell and the electronics can be replaced separately from each


other. The set parameter data are retained.
At the top of the housing is a plastic cover (5), under which the
input keys can be found.

Function
Mode of operation of the electronics

In the case of level measurements in open containers, the lowpressure connection of the measuring cell remains open
(measurement "compared to atmospheric").

0 0 00 0
00

In the case of measurements in closed containers, the lowerpressure connection has to be connected to the container in order to compensate the static pressure.

mC

The wetted parts are constructed from a variety of materials depending on the degree of corrosion resistance required.

Design

EEPROM

7
FF
interface

Power supply
10
Power
supply
unit

Coupler

Electronics
1
Sensor
pe

1
2
3
4
5
6
7

EEPROM

Measuring cell

Measuring cell sensor


Instrument amplifier
Analog-to-digital converter
Microcontroller
Electrical isolation
One non-volatile memory
each in the measuring cell
and electronics
FF interface

8
9
10

Three input keys


(local operation)
Digital display
Power supply

pe

Input variable

Function diagram of the electronics

Front view

The transmitter consists of various components depending on


the order. The possible versions are listed in the ordering information. The components described below are the same for all
transmitters.
The rating plate (3, Figure "Front view") with the Order No. is located on the side of the housing. The specified number together
with the ordering information provide details on the optional design details and on the possible measuring range (physical properties of built-in sensor element).
The approval label is located on the opposite side.
The housing is made of die-cast aluminium or stainless steel precision casting. A round cover is screwed on at the front and rear
of the housing. The front cover (6) can be fitted with a viewing
pane so that the measured values can be read directly on the digital display. The inlet (4) for the electrical connection is located
either on the left or right side. The unused opening on the opposite side is sealed by a blanking plug. The protective earth connection is located on the rear of the housing.

The bridge output voltage created by the sensor (1, Figure


"Function diagram of the electronics") is amplified by the instrument amplifier (2) and digitized in the analog-to-digital converter
(3). The digital information is evaluated in the microcontroller, its
linearity and temperature response corrected, and provided on
the Foundation Fieldbus through an electrically isolated Foundation Fieldbus Interface (7).
The data specific to the measuring cell, the electronics data, and
the parameter data are stored in the two non-volatile memories
(6). The one memory is coupled to the measuring cell, the other
to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from
each other.
Using the three input keys (8) you can parameterize the pressure
transmitter directly at the point of measurement. The input keys
can also be used to control the view of the results, the error messages and the operating modes on the digital display (9).
The results with status values and diagnostic values are transferred by cyclic data transmission on the Foundation Fieldbus. Parameterization data and error messages are transferred by acyclic data transmission. Special software such as National
Instruments Configurator is required for this.

The electrical connections for the power supply and screen are
accessible by unscrewing the rear cover. The bottom part of the
housing contains the measuring cell with process connection
(1). The measuring cell is protected from rotating by a locking
screw (8). As the result of this modular design, the measuring
Siemens FI 01 2005

2/81

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series (Foundation Fieldbus)

Mode of operation of the measuring cells


Measuring cell for pressure

Measuring cell for absolute pressure from differential pressure


series

5
4
3

1
2
3
4
5
pe

Measuring cell
Process connection
Seal diaphragm
Filling liquid
Silicon pressure sensor
Pressure as input variable

5
pe

1
2
3
4
5
6
7
8
pe

Reference vacuum
Overload diaphragm
Silicon pressure sensor
O-ring
Process flange
Seal diaphragm
Body of measuring cell
Filling liquid
Absolute pressure as
input variable

2
p

Measuring cell for absolute pressure from differential pressure series,


functional diagram

Measuring cell for pressure, functional diagram

Measuring cell for absolute pressure from pressure series


The pressure pe is applied through the process connection (2,
Figure "Measuring cell for pressure, functional diagram) to the
measuring cell (1). This pressure is subsequently transmitted
further through the seal diaphragm (3) and the filling liquid (4) to
the silicon pressure sensor (5) whose measuring diaphragm is
then flexed. The resistance of the four piezo-resistors fitted in the
diaphragm in a bridge circuit thus changes. This change in resistance results in a bridge output voltage proportional to the input pressure.

The input pressure pe is transmitted through the seal diaphragm


(6, Figure "Measuring cell for absolute pressure from differential
pressure series, functional diagram") and the filling liquid (8) to
the silicon pressure sensor (3).
The difference in pressure between the input pressure pe and
the reference vacuum (1) on the low-pressure side of the measuring cell flexes the measuring diaphragm. The resistance of the
four piezo-resistors fitted in the diaphragm in a bridge circuit
thus changes. This change in resistance results in a bridge output voltage proportional to the absolute pressure.
An overload diaphragm is installed to provide protection from
overloads. If the measuring limits are exceeded, the overload diaphragm (2) is flexed until the seal diaphragm rests on the body
of the measuring cell (7), thus protecting the silicon pressure
sensor from overloads.
Measuring cell for differential pressure and flow

5
4

3
1

pe

1
2
3
4
5
pe

Measuring cell
Process connection
Seal diaphragm
Filling liquid
Silicon absolute pressure sensor
Absolute pressure as input variable

1
5

1
2
3
4
5
6
7

Seal diaphragm
O-ring
Overload diaphragm
Silicon pressure sensor
Process flange
Body of measuring cell
Filling liquid

Measuring cell for differential pressure and flow, functional diagram


Measuring cell for absolute pressure from the pressure series, functional
diagram

The absolute pressure pe is transmitted through the seal diaphragm (3, Figure "Measuring cell for absolute pressure from
pressure series, functional diagram") and the filling liquid (4) to
the silicon absolute pressure sensor (5) whose measuring diaphragm is then flexed. The resistance of the four piezo-resistors
fitted in the diaphragm in a bridge circuit thus changes. This
change in resistance results in a bridge output voltage proportional to the input pressure.

2/82

Siemens FI 01 2005

The differential pressure is transmitted through the seal diaphragms (1, Figure "Measuring cell for differential pressure and
flow, functional diagram") and the filling liquid (7) to the silicon
pressure sensor (4).
The measuring diaphragm is flexed by the applied differential
pressure. The resistance of the four piezo-resistors fitted in the
diaphragm in a bridge circuit thus changes. This change in resistance results in a bridge output voltage proportional to the absolute pressure.
An overload diaphragm is installed to provide protection from
overloads. If the measuring limits are exceeded, the overload diaphragm (2) is flexed until the seal diaphragm rests on the body
of the measuring cell (7), thus protecting the silicon pressure
sensor from overloads.

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series (Foundation Fieldbus)
Adjustable parameters

Measuring cell for level

Parameters
3

8
+

1
2
3
4
5

10
9

Flange with tube


Seal diaphragm on
mounting flange
Seal diaphragm
Body of measuring cell
Overload diaphragm

6
7
8
9
10

Input keys

Silicon pressure sensor


O-ring
Process flange
Filling liquid
Capillary with filling liquid
of mounting flange

Measuring cell for level, functional diagram

The input pressure (hydrostatic pressure) acts hydraulically on


the measuring cell through the seal diaphragm on the mounting
flange (2, Figure "Measuring cell for level, functional diagram").
This differential pressure is subsequently transmitted further through the measuring cell (3) and the filling liquid (9) to the silicon
pressure sensor (6) whose measuring diaphragm is then flexed.
The resistance of the four piezo-resistors fitted in the diaphragm
in a bridge circuit thus changes.
This change in resistance results in a bridge output voltage proportional to the differential pressure.
An overload diaphragm is installed to provide protection from
overloads. If the measuring limits are exceeded, the overload diaphragm (2) is flexed until the seal diaphragm rests on the body
of the measuring cell (7), thus protecting the silicon pressure
sensor from overloads.

Electrical damping

Zero adjustment (correction of position)

Keys and/or function disabling

Source of measured-value display

Physical dimension of display

Position of decimal point

Bus address

Adjustment of characteristic

Input of characteristic

Freely-programmable LCD

Diagnostics functions

Diagnostic functions
Event counter
Slave pointer
Maintenance timer
Simulation functions
Display of zero correction
Limit transmitter
Saturation alarm
Physical dimensions available for the display
Physical variable

Physical dimensions

Pressure (setting can also be made


in the factory)

MPa, hPa, kPa, Pa, bar, mbar, torr,


atm, psi, g/cm2, kg/cm2, mmH20,
mmH20 (4 C), inH20, inH20
(4 C), ftH20, mmHg, inHg

Level (height data)

m, cm, mm, ft, in, yd

Volume

m3, dm3, hl, yd3, ft3, in3, US gallon, lmp, gallon, bushel, barrel,
barrel liquid

Volume flow

m3/s, m3/min, m3/h, m3/d, l/s,


l/min, l/h, l/ d, Ml/d, ft3/s, ft3/min,
ft3/h, ft3/d, US gallon/s, US gallon/min, US gallon/h, US gallon/d, bbl/s, bbl/min, bbl/h, bbl/d

Mass flow

g/s, g/min, g/h, g/d, kg/s, kg/min,


kg/h, kg/d, t/s, t/min, t/h, /t/d, lb/s,
lb/min, lb/h, lb/d, STon/s,
STon/min, STon/h, STon/d, LTon/s,
LTon/min, LTon/h, LTon/d

Total mass flow

t, kg, g, lb, oz, LTon, STon

Parameterization
Depending on the version, there are different possibilities for parameterizing the pressure transmitter and for setting or scanning
the parameters.
Parameterization using the input keys (local operation)
With the input keys you can easily set the most important parameters without any additional equipment.
Parameterization through Foundation Fieldbus Interface
Fully digital communication through Foundation Fieldbus is particularly user-friendly. Through the Foundation Fieldbus the
DS III FF is connected to a process control system. Communication is possible even in a potentially explosive environment.
For parameterization through the Foundation Fieldbus you need
suitable software, e.g. National Instruments Configurator.

Foundation Fieldbus
Interface

Temperature

K, C, F, R

Miscellaneous

Siemens FI 01 2005

2/83

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for pressure

Technical specifications

Power supply UH

Supplied through bus

SITRANS P pressure transmitters, DS III FF series, for pressure

Separate 24 V power supply neces- No


sary

Input

Bus voltage

Measured variable

Pressure

Not Ex

9 ... 32 V

Nominal measuring range

Max. working pressure

With intrinsically-safe operation

9 ... 24 V

1 bar (14.5 psi)

6 bar (87 psi)

Current consumption

4 bar (58 psi)

10 bar (145 psi)

Basic current (max.)

16 bar (232 psi)

32 bar (464 psi)

Certificates and approvals

63 bar (913 psi)

100 bar (1450 psi)

160 bar (2320 psi)

250 bar (3626 psi)

400 bar (5802 psi)

500 bar (7252 psi)

Classification according to pressure


equipment directive
(DRGL 97/23/EC)

Lower measuring limit


Measuring cell with silicone oil filling

30 mark (0.435 psi) absolute

Upper measuring limit

100% of nominal measuring


range (max. 160 bar (2320 psi)
with oxygen measurement and
inert filling liquid)
Digital Foundation Fieldbus signal

Physical bus

IEC 61158-2

Measuring accuracy
Reference conditions

Ex II 1/2 G EEx ia/ib IIB/IIC T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +70 C (-40 ... +158 F)
temperature class T5;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To a certified intrinsically-safe circuit with maximum values:


FISCO supply unit:
Uo = 17.5 V, Io = 380 mA,
Po = 5.32 W
Linear barrier:
Uo = 24 V, Io = 250 mA,
Po = 1.2 W

- Effective internal inductance/capacitance

Li = 7 H, Ci = 1.1 nF

Error in measurement (including


hysteresis and repeatability)
- Linear characteristic

0.075%

With -10 ... +60 C (14 ... 140 F)

0.3%

With -40 ... -10 C and


+60 C ... +85 C
(-40 ... +14 and 140 ... 185 F)

0.25% / 10 K ( 0.25% / 18 F)

Rated conditions
Degree of protection (to EN 60529)

IP65

Process temperature
Measuring cell with silicone oil filling

-40 ... +100 C (-40 ... +212 F)

Measuring cell with inert filling liquid

-20 ... +100 C (-4 ... +212 F)

Design
Weight (without options)

1.5 kg ( 3.3 lb)

Wetted parts materials


Connection shank

Stainless steel, mat. No.


1.4404/316L or
Hastelloy C4, mat. No. 2.4610

Seal diaphragm

Stainless steel, mat. No.


1.4404/316L or
Hastelloy C276, mat. No. 2.4819

Measuring cell filling

Silicone oil or inert filling liquid


(max. 160 bar (2320 psi) with oxygen measurement)

Process connection

Connection shank GA to DIN


EN 837, female thread -14 NPT
or oval flange (PN 160
(MWP 2320)) to DIN 19213 with
mounting thread M10 or
7/ -20 UNF to EN 61518
16

2/84

Siemens FI 01 2005

PTB 99 ATEX 2122

- Identification

Increasing characteristic, start-ofscale value 0 bar, stainless steel


seal diaphragm, silicone oil filling,
room temperature (25 C (77 F))

Influence of ambient temperature

For gases of fluid group 1 and


liquids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)

Explosion protection
Intrinsic safety "i"

Output

12.5 mA

Explosion-proof "d"

Planned

Type of protection "n" (zone 2)

Planned

Explosion protection to FM

Planned

Explosion protection to CSA

Planned

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for pressure

Dimensional drawings
55
(0.6)

36,5
(1,44)

120 (4.7)

1)

68 (2.7)

117 (4.6)
1)

100 (3.94)

72 (2.8)

approx. 30 (1.2)

28
(1.1)

50
(1.97)

50
(1.97)

20
(0.8)

69
(2.7)

171 (6.7)
237 (9.3)

138 (5.4)

80
(3.15)

15
(0.6)

123 (4.8)
min. 77 (3.0) 2)

7
105 (4.1)

2
3
4
5
6
7
8

Process connection:
- -14 NPT,
- connection shank GA or
- oval flange
Blanking plug
Electrical connection:
- screwed gland M20x1,5 3) or
- screwed gland -14 NPT
Terminal side
Electronics side (long er overall length for cover
with window)
Safety cover over keys
Mounting bracket (option)
Screw cover safety bracket (only for explosion-proof
cover, not shown in the drawing)

1)
2)
3)

Allow approx. 20 mm (0.79 inch) thread length in addition


Minimum distance to permit rotation
Not for type of protection "FM + CSA".

SITRANS P pressure transmitters, DS III FF series for pressure, dimensional drawing, dimensions in mm (inch)

Siemens FI 01 2005

2/85

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for pressure

Selection and Ordering data

Order No.

Further designs

SITRANS P pressure transmitter for pressure

7MF 4 0 3 5 -

Please add "-Z" to Order No. and specify Order code.

DS III FF series

77777 - 7777

Pressure transmitter with mounting bracket made of:


Steel
A01
Stainless steel
A02

Measuring cell filling


Silicone oil
Inert liquid1)

Measuring cell cleaning


Standard
Grease-free

Rated measuring range


1 bar
(14.5 psi)
4 bar
(58 psi)
16 bar
(232 psi)
63 bar
(914 psi)
160 bar
(2320 psi)
400 bar
(5802 psi)

1
3

Rating plate inscription


(instead of German)
English
French
Spanish
Italian

B
C
D
E
F
G

Wetted parts materials


Seal diaphragm
Process connection
Stainless steel
Stainless steel
Hastelloy
Stainless steel
Hastelloy
Hastelloy
Version as diaphragm seal
Process connection
Connection shank GB to EN 837-1
Female thread -14 NPT
Oval flange made of stainless steel,
max. span 160 bar (2320 psi)
- Mounting thread 7/16-20 UNF to EN 61518
- Mounting thread M10 to DIN 19213
Non-wetted parts materials
Housing made of die-cast aluminium
Housing stainless steel precision casting
Design
Standard design
International version, English label inscriptions,
documentation in 5 languages on CD
Explosion protection
without
with CENELEC, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 2) (planned)
- "Intrinsic safety and explosion-proof enclosure
(EEx ia + EEx d)" 3) (planned)
- "n (zone 2)" (planned)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 1)
(planned)
Electrical connection / cable inlet
Screwed gland M20x1.5
Screwed gland -14 NPT
Display
without (digital display hidden)
with visible digital indicator
with customer-specific digital indicator (setting
as specified, Order code "Y21" required)

A
B
C
Y0
0
1

2
3
0
3
1
2

A
B
D
P

2/86

Siemens FI 01 2005

B11
B12
B13
B14

English rating plate


Pressure units in inH2O or psi

B21

Manufacturer's test certificate M


to DIN 55.350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10 204-3.1B

C12

Factory certificate
to EN 10.204-2.2

C14

Acid gas version to NACE


(only together with seal diaphragm made of Hastelloy)

D07

Type of protection IP68


(not together with nominal measuring range 63 bar
( 914 psi))

D12

Digital indicator along side the input keys


(only together with the devices 7MF4035-....0-.A.6 or
-.A.7-Z, Y21)

D27

Use on zone 1D / 2D
(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

Oxygen application
(max. 160 bar (2320 psi) with oxygen measurement
and inert liquid)

E10

Additional data

E
NC

B
C
1
6
7

The device is delivered together with brief instructions (Leporello) and


a CD-ROM containing detailed documentation.
1) For oxygen application, add Order code E10.
2) Without cable gland, with blanking plug
3) With enclosed cable gland EEx ia and blanking plug

Order code

Measuring point number/identification


Max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Setting of pressure indicator in pressure units


specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C

Y21

Only the settings for "Y21" can be made in the factory.


Ordering example
Item line: 7MF4034-1EA00-1AA7-Z
B line: A01 + Y21
C line: Y21: ... mbar

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for absolute pressure
(from pressure series)

Technical specifications

Power supply UH

SITRANS P pressure transmitters, DS III FF series for absolute pressure, from the pressure series

Bus voltage

Input
Measured variable

Absolute pressure

Nominal measuring range

Max. working pressure

250 mbar (3.6 psi)

6 bar (87 psi)

1300 mbar (18.9 psi)

10 bar (145 psi)

5 bar (72.5 psi)

30 bar (435 psi)

30 bar (435 psi)

100 bar (1450 psi)

Lower measuring limit


Measuring cell with silicone oil filling

0 mbar absolute

Upper measuring limit

100% of nominal measuring


range (max. 160 bar (2320 psi)
with oxygen measurement and
inert filling liquid)

Output

Digital Foundation Fieldbus signal

Physical bus

IEC 61158-2

Not Ex

9 ... 32 V

With intrinsically-safe operation

9 ... 24 V

Current consumption
Basic current (max.)

Increasing characteristic
Start-of-scale value 0 bar
Stainless steel seal diaphragm
Silicone oil filling
Room temperature (25 C (77 F))

Classification according to pressure


equipment directive
(DRGL 97/23/EC)

- Linear characteristic

Intrinsic safety "i"

0.3%

With -40 ... -10 C and


+60 C ... +85 C
(-40 ... +14 and 140 ... 185 F)

0.25% / 10 K ( 0.25% / 18 F)

PTB 99 ATEX 2122

- Identification

Ex II 1/2 G EEx ia/ib IIB/IIC T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +70 C (-40 ... +158 F)
temperature class T5;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To a certified intrinsically-safe circuit with maximum values:


FISCO supply unit:
Uo = 17.5 V, Io = 380 mA,
Po = 5.32 W
Linear barrier:
Uo = 24 V, Io = 250 mA,
Po = 1.2 W

- Effective internal inductance/capacitance

L i = 7 H, Ci = 1.1 nF

0.075%

With -10 ... +60 C (14 ... 140 F)

For gases of fluid group 1 and


liquids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)

Explosion protection

Error in measurement (including


hysteresis and repeatability)
Influence of ambient temperature

12.5 mA

Certificates and approvals

Measuring accuracy
Reference conditions

Supplied through bus

Separate 24 V power supply neces- No


sary

Explosion-proof "d"

Planned

Type of protection "n" (zone 2)

Planned

Rated conditions

Explosion protection to FM

Planned

Degree of protection (to EN 60529)

Explosion protection to CSA

Planned

IP65

Process temperature
Measuring cell with silicone oil filling

-40 ... +100 C (-40 ... +212 F)

Design
Weight (without options)

1.5 kg ( 3.3 lb)

Wetted parts materials


Connection shank

Stainless steel, mat. No.


1.4404/316L or
Hastelloy C4, mat. No. 2.4610

Seal diaphragm

Stainless steel, mat. No.


1.4404/316L or
Hastelloy C276, mat. No. 2.4819

Measuring cell filling

Silicone oil or inert filling liquid


(max. 160 bar (2320 psi) with oxygen measurement)

Process connection

Connection shank GA to DIN


EN 837, female thread -14 NPT
or oval flange (PN 160
(MWP 2320)) to DIN 19,213 with
mounting thread M10 or
7/ -20 UNF to EN 61518
16

Siemens FI 01 2005

2/87

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for absolute pressure
(from pressure series)

Dimensional drawings
55
(0.6)

1)

120 (4.7)

72 (2.8)

36,5
(1,44)

117 (4.6)
1)

100 (3.94)

68 (2.7)

approx. 30 (1.2)

28
(1.1)

50
(1.97)

50
(1.97)

69
(2.7)

171 (6.7)
237 (9.3)

138 (5.4)

20
(0.8)

15
(0.6)

80
(3.15)

123 (4.8)
min. 77 (3.0) 2)

7
105 (4.1)

2
3
4
5
6
7
8

Process connection:
- -14 NPT,
- connection shank GA or
- oval flange
Blanking plug
Electrical connection:
- screwed gland M20x1,5 3) or
- screwed gland -14 NPT
Terminal side
Electronics side (long er overall length for cover
with window)
Safety cover over keys
Mounting bracket (option)
Screw cover safety bracket (only for explosion-proof
cover, not shown in the drawing)

1)
2)
3)

Allow approx. 20 mm (0.79 inch) thread length in addition


Minimum distance to permit rotation
Not for type of protection "FM + CSA".

SITRANS P pressure transmitters, DS III FF series for absolute pressure, from the pressure series, dimensional drawing, dimensions in mm (inch)

2/88

Siemens FI 01 2005

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for absolute pressure
(from pressure series)
Selection and Ordering data

Order No.

Further designs

SITRANS P pressure transmitters


for absolute pressure from the pressure series

7MF 4 2 3 5 -

Please add "-Z" to Order No. and specify Order code.

DS III FF series

77777 - 7777

Pressure transmitter with mounting bracket made of:


Steel
A01
Stainless steel
A02

Measuring cell filling


Silicone oil
Inert liquid1)

Measuring cell cleaning


Standard
Grease-free

Rated measuring range


250 mbar
(3.63 psi)
1300 mbar
(18.9 psi)
5 bar
(72.5 psi)
30 bar
(435 psi)

E)
E)
E)

1
3

Rating plate inscription


(instead of German)
English
French
Spanish
Italian

D
F
G
H

Process connection
Connection shank GB to EN 837-1
Female thread -14 NPT
Oval flange made of stainless steel, max. span
160 bar (2320 psi)
- Mounting thread 7/16-20 UNF to EN 61518
- Mounting thread M10 to DIN 19213
Non-wetted parts materials
Housing made of die-cast aluminium
Housing stainless steel precision casting
Design
Standard design
International version, English label inscriptions,
documentation in 5 languages on CD
Explosion protection
without
with CENELEC, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 3) (planned)
- "Intrinsic safety and explosion-proof enclosure
(EEx ia + EEx d)" 4) (planned)
- "n (zone 2)" (planned)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 3)
(planned)
Electrical connection / cable inlet
Screwed gland M20x1.5
Screwed gland -14 NPT

E)
E)

B21

Manufacturer's test certificate M


to DIN 55350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10204-3.1B

C12

Factory certificate
to EN 10204-2.2

C14

Acid gas version to NACE


(only together with seal diaphragm made of Hastelloy)

D07

Type of protection IP68

D12

Digital indicator along side the input keys


(only together with the devices 7MF4235-...0-.A.6 or .A.7-Z, Y21)

D27

Use on zone 1D / 2D
(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

Oxygen application
(max. 160 bar (2320 psi) with oxygen measurement
and inert liquid)

E10

A
B
D
P

Additional data

A
B
C
Y0
0
1

2
3
0
3
1
2

E
NC

B
C

Display
without (digital display hidden)
with visible digital indicator
with customer-specific digital indicator (setting
as specified, Order code "Y21" required)

1
6
7

The device is delivered together with brief instructions (Leporello) and


a CD-ROM containing detailed documentation.
1)
2)
3)
4)
E)

B11
B12
B13
B14

English rating plate


Pressure units in inH2O or psi

Wetted parts materials


Seal diaphragm
Process connection
Stainless steel
Stainless steel
Hastelloy
Stainless steel
Hastelloy
Hastelloy
Version as diaphragm seal 2)

Order code

Measuring point number/identification


max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Setting of pressure indicator in pressure units


specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C

Y21

Only the settings for "Y21" can be made in the factory

For oxygen application, add Order code E10.


Version 7MF4235-1DY... only up to max. span 200 mbar (2.9 psi)
Without cable gland, with blanking plug
With enclosed cable gland EEx ia and blanking plug
Combinations of the versions marked with E) are subject to the export
regulations AL: 2B230, ECCN: N

Siemens FI 01 2005

2/89

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for absolute pressure
(from differential pressure series)

Technical specifications

Power supply

SITRANS P pressure transmitters, DS III FF series for absolute pressure, from the differential pressure series

Bus voltage

Mode of operation and system


design
Measuring principle

Supplied through bus

Separate 24 V power supply neces- No


sary

Piezo-resistive

Not Ex

9 ... 32 V

With intrinsically-safe operation

9 ... 24 V

Current consumption

Input
Measured variable

Absolute pressure

Basic current (max.)

Nominal measuring range

Max. working pressure

Certificates and approvals

250 mbar (3.6 psi)

32 bar (464 psi)

1300 mbar (18.9 psi)

32 bar (464 psi)

Classification according to pressure


equipment directive
(DRGL 97/23/EC)

5 bar (72.5 psi)

32 bar (464 psi)

30 bar (435 psi)

160 bar (2320 psi)

100 bar (1450 psi)

160 bar (2320 psi) with pressure


cover screws M10 and
7/ -20 UNF
16

Lower measuring limit

12.5 mA
For gases of fluid group 1 and
liquids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)

Explosion protection
Intrinsic safety "i"

PTB 99 ATEX 2122

- Identification

Ex II 1/2 G EEx ia/ib IIB/IIC T6


-40 ... +85 C (-40 ... +185 F)
temperature class T4;
-40 ... +70 C (-40 ... +158 F)
temperature class T5;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

Measuring cell with silicone oil filling

0 mbar absolute

- Permissible ambient temperature

Upper measuring limit

100% of nominal measuring


range (max. 160 bar (2320 psi)
with oxygen measurement and
inert filling liquid)

- Connection

Output

Digital Foundation Fieldbus signal

Physical bus

IEC 61158-2

To a certified intrinsically-safe circuit with maximum values:


FISCO supply unit:
Uo = 17.5 V, Io = 380 mA,
Po = 5.32 W
Linear barrier:
Uo = 24 V, Io = 250 mA,
Po = 1.2 W

- Effective internal inductance/capacitance

Li = 7 H, Ci = 1.1 nF

Measuring accuracy
Reference conditions

Increasing characteristic
Start-of-scale value 0 bar
Stainless steel seal diaphragm
Silicone oil filling
Room temperature (25 C (77 F))

Error in measurement (including


hysteresis and repeatability)
- Linear characteristic

0.075%

Influence of ambient temperature


With -10 ... +60 C (14 ... 140 F)

0.3%

With -40 ... -10 C and


+60 C ... +85 C
(-40 ... +14 and 140 ... 185 F)

0.25% / 10 K ( 0.25% / 18 F)

Rated conditions
Degree of protection (to EN 60529)

IP65

Process temperature
- Measuring cell with silicone oil fil- -40 ... +100 C (-40 ... +212 F)
ling
Design
Weight (without options)

4.5 kg ( 9.9 lb)

Wetted parts materials


- Seal diaphragm

Stainless steel, mat. No.


1.4404/316L,
Hastelloy C276, mat. No. 2.4819,
Monel, mat. No. 2.4360, tantalum
or gold

Measuring cell filling

Silicone oil or inert filling liquid


(max. 160 bar (2320 psi) with oxygen measurement)

Process connection

Female thread 1/4-18 NPT and


flange connection to DIN 19213
with mounting thread M10 or
7/ -20 UNF to EN 61518
16

2/90

Siemens FI 01 2005

Explosion-proof "d"

Planned

Type of protection "n" (zone 2)

Planned

Explosion protection to FM

Planned

Explosion protection to CSA

Planned

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for absolute pressure
(from differential pressure series)

Dimensional drawings
approx. 30 (1.2)

50
(1.97)

3
approx. 261 (10.3)

198 (7.8)

134 (5.27)

1
+

Space for rotation


of housing

10
8

7
11

72 (2.83)
105 (4.1)
1
2
3
4
5
6
7
8
9
10
11

Process connection -18 NPT (EN 61518)


Blanking plug
Electrical connection
- screwed gland M20x1,5 3) or
- screwed gland -14 NPT
Terminal side
Electronics side, digital display (longer overall length for cover with window)
Protective cover over keyes
Mounting bracket (option)
Sealing screw with valve (option)
Screw cover safety bracket (only for explosion-proof enclosure,
not shown in the drawing)
Lateral venting for liquid measurement
Lateral venting for gas measurement (suffix H02)

52 (2.05)

96 (3.8)

117 (4.6)

80
(3.15)
5 1)

1)

69 (2.7)
77 (3) 2)

100 (3.94)

50
(1.97)

138 (5.4)

20
(0.8)

15
(0.6)

68 (2.7)
120 (4.7)

1)
2)
3)

Allow approx. 20 mm (0.79 inch) thread length in addition


92 mm (3.62 inch) for minimum distance to permit rotation with indicator
Not with type of protection "FM + CSA"

SITRANS P pressure transmitters, DS III FF series for absolute pressure, from the differential pressure series, dimensional drawing, dimensions in mm
(inch)

Siemens FI 01 2005

2/91

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for absolute pressure
(from differential pressure series)

Selection and Ordering data

Order No.

SITRANS P pressure transmitters


for absolute pressure from the series
Differential pressure

7MF 4 3 3 5 -

DS III FF series

77777 - 7777

Measuring cell filling


Silicone oil
Inert liquid1)

Measuring cell cleaning


Standard
Grease-free

Rated measuring range


250 mbar
(3.63 psi)
1300 mbar
(18.9 psi)
5 bar
(72.5 psi)
30 bar
(435 psi)
100 bar
(1450 psi)

E)
E)
E)

Process connection
Female thread -18 NPT with flange connection
Sealing screw opposite process connection
- Mounting thread M10 to DIN 19 213
- Mounting thread 7/16-20 UNF to
EN 61518
Vent on side of process flange 3)
- Mounting thread M10 to DIN 19 213
- Mounting thread 7/16-20 UNF to
EN 61518

E)
E)
E)

1
3
D
F
G
H
KE

A
B
C
E
H
L
Y

0
2

4
6

Non-wetted parts materials


Process flange screws Electronics housing
Stainless steel
Stainless steel

Die-cast aluminium
Stainless steel precision
casting

2
3

Design
Standard design
International version, English label inscriptions,
documentation in 5 languages on CD
Explosion protection
without
with CENELEC, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 4) (planned)
- "Intrinsic safety and explosion-proof enclosure
(EEx ia + EEx d)" 5) (planned)
- "n (zone 2)" (planned)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 4)
(planned)
Electrical connection / cable inlet
Screwed gland M20x1.5
Screwed gland -14 NPT
Display
without (digital display hidden)
with visible digital indicator
with customer-specific digital indicator (setting
as specified, Order code "Y21" required)
Included in delivery of the device:
Brief instructions (Leporello)
CD-ROM with detailed documentation
Sealing plug(s) or sealing screw(s) for the process flanges(s)

2/92

Siemens FI 01 2005

For oxygen application, add Order code E10.


Version 7MF4335-1DY... only up to max. span 200 mbar (2.9 psi)
Not for nominal measuring range 100 bar (1450 psi).
Without cable gland, with blanking plug
With enclosed cable gland EEx ia and blanking plug

E) Combinations of the versions marked with E) are subject to the export


regulations AL: 2B230, ECCN: N.

Wetted parts materials


Seal diaphragm
Parts of measuring cell
Stainless steel
Stainless steel
Hastelloy
Stainless steel
Hastelloy
Hastelloy
Tantalum
Tantalum
Monel
Monel
Gold
Gold
Version as diaphragm seal 2)

1)
2)
3)
4)
5)

1
2

A
B
D
P
E
NC

B
C
1
6
7

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for absolute pressure
(from differential pressure series)
Further designs

Order code

Order code

Further designs

Please add "-Z" to Order No. and specify Order code.

Please add "-Z" to Order No. and specify Order code.

Pressure transmitter with mounting bracket made of:


Steel
A01
Stainless steel
A02

Additional data

O-rings for process flanges


(instead of FPM (Viton))
PTFE (Teflon)
FEP (with silicone core, approved for food)
FFPM (Kalrez, compound 4079)
NBR (Buna N)

A20
A21
A22
A23

Sealing screws
-18 NPT, with valve in material of process flanges

A40

Rating plate inscription


(instead of German)
English
French
Spanish
Italian

B11
B12
B13
B14

English rating plate


Pressure units in inH2O or psi

B21

Manufacturer's test certificate M


to DIN 55350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10204-3.1B

C12

Factory certificate
to EN 10204-2.2

C14

Acid gas version to NACE


(only together with seal diaphragm made of Hastelloy
and process flange screws made of stainless steel)

D07

Type of protection IP68

D12

Digital indicator along side the input keys


(only together with the devices 7MF4335-...0.2-.A.6 or
-.A.7-Z, Y21)

D27

Use on zone 1D / 2D
(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

Oxygen application
(max. 160 bar (2320 psi) with oxygen measurement
and inert liquid)

E10

Interchanging of process connection side

H01

Vent on side for gas measurements

H02

Process flange
Hastelloy
Monel
Stainless steel with PVDF insert
max. PN 10 (MWP 145 psi)
max. temperature of medium 90 C (194 F)

K01
K02
K04

Measuring point number/identification


max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Setting of pressure indicator in pressure units


specify in plain text
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C

Y21

Only the settings for "Y21" can be made in the factory.

Siemens FI 01 2005

2/93

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for differential pressure and flow

Technical specifications

Design

SITRANS P pressure transmitters, DS III FF series, for differential


pressure and flow
Input
Measured variable

Differential pressure and flow

Nominal measuring range

Max. working pressure

PN 32 (MWP 464 psi)


- 20 mbar (0.29 psi)

32 bar (464 psi)

Weight (without options)

4.5 kg ( 9.9 lb)

Wetted parts materials


Seal diaphragm

Stainless steel, mat. No.


1.4404/316L,
Hastelloy C276, mat. No. 2.4819,
Monel, mat. No. 2.4360, tantalum
or gold

Measuring cell filling

Silicone oil or inert filling liquid


(max. 160 bar (2320 psi) with oxygen measurement)

Process connection

Female thread 1/4-18 NPT and


flange connection to DIN 19213
with mounting thread M10 or
7/ -20 UNF to EN 61518
16
Supplied through bus

PN 160 (MWP 2320 psi)


- 60 mbar (0.87 psi)

160 bar (2320 psi)

- 250 mbar (3.63 psi)

160 bar (2320 psi)

- 600 mbar (8.7 psi)

160 bar (2320 psi)

- 1600 mbar (23.3 psi)

160 bar (2320 psi)

Power supply UH

- 5 bar (72.5 psi)

160 bar (2320 psi)

Separate 24 V power supply neces- No


sary

- 30 bar (435 psi)

160 bar (2320 psi)

Bus voltage

PN 400 (MWP 6092 psi)

Not Ex

9 ... 32 V

With intrinsically-safe operation

9 ... 24 V

- 250 mbar (3.63 psi)

420 bar (6092 psi)

- 600 mbar (8.7 psi)

420 bar (6092 psi)

Current consumption

- 1600 mbar (23.3 psi)

420 bar (6092 psi)

Basic current (max.)

- 5 bar (72.5 psi)

420 bar (6092 psi)

Certificates and approvals

- 30 bar (435 psi)

420 bar (6092 psi)

Classification according to pressure


equipment directive
(DRGL 97/23/EC)

Lower measuring limit


Measuring cell with silicone oil filling

-100% of nominal measuring


range (-33% with nominal measuring range 30 bar (435 psi)) or
30 mbar (0.435 psi) absolute

Upper measuring limit

100% of nominal measuring


range (max. 160 bar (2320 psi)
with oxygen measurement and
inert filling liquid)

Output

Digital Foundation Fieldbus signal

Physical bus

IEC 61158-2

- PN 32/160 (MWP 464/2320)

For gases of fluid group 1 and


liquids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)

- PN 420 (MWP 6092)

For gases of fluid group 1 and


liquids of fluid group 1; complies
with basic safety requirements of
article 3, paragraph 1 (appendix
1); assigned to category III, conformity evaluation module H by
the TV Nord

Measuring accuracy
Reference conditions

Increasing characteristic
Start-of-scale value 0 bar
Stainless steel seal diaphragm
Silicone oil filling
Room temperature (25 C (77 F))

Error in measurement (including


hysteresis and repeatability)
- Linear characteristic

0.075%

- Square-root characteristic, flow


> 50 %

0.1%

- Square-root characteristic, flow


25 ... 50 %

0.2%

Explosion protection
Intrinsic safety "i"

0.3% (Twice the value with


20-mbar (0.29 psi) nominal
measuring range)

With -40 ... -10 C and


+60 C ... +85 C
(-40 ... +14 and 140 ... 185 F)

0.25% / 10 K ( 0.25% / 18 F)
(Twice the value with 20 mbar
(0.29 psi) nominal measuring
range)

Rated conditions
Degree of protection (to EN 60529)

IP65

Process temperature
Measuring cell with silicone oil filling

2/94

Siemens FI 01 2005

-40 ... +100 C (-40 ... +212 F)

PTB 99 ATEX 2122

- Identification

Ex II 1/2 G EEx ia/ib IIB/IIC T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +70 C (-40 ... +158 F)
temperature class T5;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To a certified intrinsically-safe circuit with maximum values:


FISCO supply unit:
Uo = 17.5 V, Io = 380 mA,
Po = 5.32 W
Linear barrier:
Uo = 24 V, Io = 250 mA,
Po = 1.2 W

- Effective internal inductance/capacitance

Li = 7 H, Ci = 1.1 nF

Influence of ambient temperature


With -10 ... +60 C (14 ... 140 F)

12.5 mA

Explosion-proof "d"

Planned

Type of protection "n" (zone 2)

Planned

Explosion protection to FM

Planned

Explosion protection to CSA

Planned

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for differential pressure and flow

Dimensional drawings
approx. 30 (1.2)

50
(1.97)

3
approx. 261 (10.3)

198 (7.8)

134 (5.27)

1
+

Space for rotation


of housing

10
8

7
11

72 (2.83)
105 (4.1)
1
2
3
4
5
6
7
8
9
10
11

Process connection -18 NPT (EN 61518)


Blanking plug
Electrical connection
- screwed gland M20x1,5 3) or
- screwed gland -14 NPT
Terminal side
Electronics side, digital display (longer overall length for cover with window)
Protective cover over keyes
Mounting bracket (option)
Sealing screw with valve (option)
Screw cover safety bracket (only for explosion-proof enclosure,
not shown in the drawing)
Lateral venting for liquid measurement
Lateral venting for gas measurement (suffix H02)

52 (2.05)

96 (3.8)

117 (4.6)

80
(3.15)
5 1)

1)

69 (2.7)
77 (3) 2)

100 (3.94)

50
(1.97)

138 (5.4)

20
(0.8)

15
(0.6)

68 (2.7)
120 (4.7)

1)
2)
3)

Allow approx. 20 mm (0.79 inch) thread length in addition


92 mm (3.62 inch) for minimum distance to permit rotation with indicator
Not with type of protection "FM + CSA"

SITRANS P pressure transmitters, DS III FF series for differential pressure and flow, dimensional drawing, dimensions in mm (inch)

Siemens FI 01 2005

2/95

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for differential pressure and flow

138 (5.4)

80
(3.15)
4
5
6
7
8
9

Process connection: -18 NPT (EN 61518)


Blanking plug
Electrical connection:
- screwed gland M20x1,5 3) or
- screwed gland -14 NPT
Terminal side
Electronics side, digital display (longer overall length for cover with window)
Safety cover over keys
Mounting bracket (option)
Sealing screw with valve (option)
Screw cover safety bracket (only for explosion-proof enclosure,
not shown in the drawing)

8
1

ca. 84,6 (3.33)

67 (2.64)4)

1
2
3

ca. 85 (3.35)5)

77 (3)3)

4 1)

5 1)

100 (3.94)

50
(1.97)

69 (2.7)

approx. 30approx.
(1.18)
20
(0.8)

50
(1.97)

approx. 217 (8.54)6)

15
(0.6)

Space for rotation


of housing

1)
2)
3)
4)
5)
6)

Allow approx. 20 mm (0.79 inch) thread length in addition


Not for type of protection "FM + CSA [is + xp]"
92 mm (3.6 inch) minimum distance to permit rotation with indicator
74 mm (2.9 inch) for PN 420 (MWP 6092 psi)
91 mm (3.6 inch) for PN 420 (MWP 6092 psi)
219 mm (8.62 inch) for PN 420 (MWP 6092 psi)

SITRANS P pressure transmitters, DS III FF series for differential pressure and flow, with process covers for vertical differential pressure lines, dimensional drawing, dimensions in mm (inch)

SITRANS P pressure transmitters, DS III FF series for differential pressure


and flow, with process covers for vertical differential pressure lines

2/96

Siemens FI 01 2005

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for differential pressure and flow
4

115 (4.5)

183 (7.2)

77
(3.0)

193 (7.6)

FIELD
TERMINALS
3

1
2
3
4
5
6
7
8

Process connection, -18 NPT (EN 61 518)


Terminal side, analog indicator (optional)
External digital indicator (optional)
Sealing plug
Fixing screw
Blanking plug
Protective cover for keys
Electrical connection

SITRANS P pressure transmitters, DS III FF series for differential pressure and flow, with digital indicator beside control keys, dimensional drawing,
dimensions in mm (inch)

SITRANS P pressure transmitters, DS III FF series for differential pressure


and flow, with digital indicator beside control keys

Siemens FI 01 2005

2/97

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for differential pressure and flow

Selection and Ordering data

Order No.

Selection and Ordering data

Order No.

SITRANS P pressure transmitters


for differential pressure and flow

7MF 4 4 3 5 -

SITRANS P pressure transmitters


for differential pressure and flow

7MF 4 4 3 5 -

DS III FF series, PN 32 / 160 (MWP 464 / 2320 psi)

77777 - 7777

DS III FF series, PN 32 / 160 (MWP 464 / 2320 psi)

77777 - 7777

Measuring cell filling


Silicone oil
Inert liquid1)

Measuring cell cleaning


Standard
Grease-free

Display
without (digital display hidden)
with visible digital indicator
with customer-specific digital indicator (setting
as specified, Order code "Y21" required)

1
3

Rated measuring range


PN 32 (MWP 464 psi)
20 mbar 2)
(0.29 psi)

PN 160 (MWP 2320 psi)


60 mbar
250 mbar
600 mbar
1600 mbar
5000 mbar
30 bar

C
D
E
F
G
H

(0.87 psi)
(3.63 psi)
(8.70 psi)
(23.2 psi)
(72.5 psi)
(435 psi)

Included in delivery of the device:


Brief instructions (Leporello)
CD-ROM with detailed documentation
Sealing plug(s) or sealing screw(s) for the process flanges(s)
1) For oxygen application, add Order code E10
2) Not suitable for connection of remote seal
3) Only together with max. spans 250, 1600, 5000 and 30000 mbar
(3.63, 23.2, 72.5 and 435 psi).
4) Without cable gland, with blanking plug
5) With enclosed cable gland EEx ia and blanking plug

Wetted parts materials


(stainless steel process flanges)
Seal diaphragm
Parts of measuring cell
Stainless steel
Stainless steel
Hastelloy
Stainless steel
Hastelloy
Hastelloy
Tantalum 3)
Tantalum
Monel 3)
Monel
Gold 3)
Gold
Version as diaphragm seal
Process connection
Female thread -18 NPT with flange connection
Sealing screw opposite process connection
- Mounting thread M10 to DIN 19 213

A
B
C
E
H
L
Y

- Mounting thread 7/16-20 UNF to EN 61518


Venting on side of process flanges
- Mounting thread M10 to DIN 19 213

- Mounting thread 7/16-20 UNF to EN 61518

Non-wetted parts materials


Process flange screws Electronics housing
Stainless steel
Stainless steel

Die-cast aluminium
Stainless steel precision
casting

Design
Standard design
International version, English label inscriptions,
documentation in 5 languages on CD
Explosion protection
without
with CENELEC, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 4) (planned)
- "Intrinsic safety and explosion-proof enclosure
(EEx ia + EEx d)" 5) (planned)
- "n (zone 2)" (planned)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 4)
(planned)
Electrical connection / cable inlet
Screwed gland M20x1.5
Screwed gland -14 NPT

2/98

Siemens FI 01 2005

2
3

1
2

A
B
D
P
E
NC

B
C

1
6
7

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for differential pressure and flow
Further designs

Order code

Order code

Further designs

Please add "-Z" to Order No. and specify Order code.

Please add "-Z" to Order No. and specify Order code.

Pressure transmitter with mounting bracket made of:


Steel
A01
Stainless steel
A02

Additional data

O-rings for process flanges


(instead of FPM (Viton))
PTFE (Teflon)
FEP (with silicone core, approved for food)
FFPM (Kalrez, compound 4079)
NBR (Buna N)

A20
A21
A22
A23

Sealing screws
-18 NPT, with valve in material of process flanges

A40

Rating plate inscription


(instead of German)
English
French
Spanish
Italian

B11
B12
B13
B14

English rating plate


Pressure units in inH2O or psi

B21

Manufacturer's test certificate M


to DIN 55350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10204-3.1B

C12

Factory certificate
to EN 10204-2.2

C14

Acid gas version to NACE


(only together with seal diaphragm made of Hastelloy
and process flange screws made of stainless steel)

D07

Type of protection IP68

D12

Digital indicator along side the input keys


(only together with the devices 7MF4435-....0-.A.6 or
-.A.7-Z, Y21)

D27

Use on zone 1D / 2D
(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

Oxygen application
(max. 160 bar (2320 psi) with oxygen measurement
and inert liquid)

E10

Interchanging of process connection side

H01

Vent on side for gas measurements

H02

Stainless steel process flanges for vertical


differential pressure lines
(not together with K01, K02 and K04) 1)

H03

Process flange
Hastelloy
Monel
Stainless steel with PVDF insert
max. PN 10 (MWP 145 psi)
max. temperature of medium 90 C (194 F)

Measuring point number/identification


max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Setting of pressure indicator in pressure units


specify in plain text
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C

Y21

Only the settings for "Y21" can be made in the factory


1) Not suitable for connection of remote seal

K01
K02
K04

Siemens FI 01 2005

2/99

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for differential pressure and flow

Selection and Ordering data

Order No.

Further designs

SITRANS P pressure transmitters


for differential pressure and flow

7MF 4 5 3 5 -

Please add "-Z" to Order No. and specify Order code.

DS III FF series, PN 420 (MWP 6092 psi)

1 7777 - 7777

Pressure transmitter with mounting bracket made of:


Steel
A01
Stainless steel
A02

Rated measuring range


250 mbar
(3.63 psi)
600 mbar
(8.70 psi)
1600 mbar
(23.2 psi)
5 bar
(72.5 psi)
30 bar
(435 psi)

D
E
F
G
H

Wetted parts materials


(stainless steel process flanges)
Seal diaphragm
Parts of measuring cell
Stainless steel
Hastelloy
Gold 1)

Stainless steel
Stainless steel
Gold

Process connection
Female thread -18 NPT with flange connection
to DIN 19 213
Sealing screw opposite process connection
- Mounting thread M12 to DIN 19 213
- Mounting thread 7/16-20 UNF to EN 61518
Venting on side of process flanges
- Mounting thread M12 to DIN 19 213
- Mounting thread 7/16-20 UNF to EN 61518

A
B
L

Die-cast aluminium
Stainless steel precision
casting

Included in delivery of the device:


Brief instructions (Leporello)
CD-ROM with detailed documentation
Sealing plug(s) or sealing screw(s) for the process flanges(s)
1) Not together with max. span 600 mbar
2) Without cable gland, with blanking plug
3) With enclosed cable gland EEx ia and blanking plug

B11
B12
B13
B14

Acceptance test certificate B


to EN 10 204-3.1B

C12

Factory certificate
to EN 10.204-2.2

C14

Acid gas version to NACE


(only together with seal diaphragm made of Hastelloy
and process flange screws made of stainless steel)

D07

Type of protection IP68

D12

Digital indicator along side the input keys


(only together with the devices 7MF4535-...0.2-.A.6 or
-.A.7-Z, Y21)

D27

Use on zone 1D / 2D
(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

Interchanging of process connection side

H01

NC

Stainless steel process flanges for vertical


differential pressure lines

H03

2
3

Display
without (digital display hidden)
with visible digital indicator
with customer-specific digital indicator (setting
as specified, Order code "Y21" required)

A40

Rating plate inscription


(instead of German)
English
French
Spanish
Italian

C11

Electrical connection / cable inlet


Screwed gland M20x1.5
Screwed gland -14 NPT

Sealing screws
-18 NPT, with valve in material of process flanges

Manufacturer's test certificate M


to DIN 55.350, Part 18 and to ISO 8402

Explosion protection
without
with CENELEC, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 2) (planned)
- "Intrinsic safety and explosion-proof enclosure
(EEx ia + EEx d)" 3) (planned)
- "n (zone 2)" (planned)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 2)
(planned), max. PN 360

A20
A21
A22
A23

B21

Design
Standard design
International version, English label inscriptions,
documentation in 5 languages on CD

O-rings for process flanges


(instead of FPM (Viton))
PTFE (Teflon)
FEP (with silicone core, approved for food)
FFPM (Kalrez, compound 4079)
NBR (Buna N)

English rating plate


Pressure units in inH2O or psi

Non-wetted parts materials


Process flange screws Electronics housing
Stainless steel
Stainless steel

1
2

A
B
D
P

Additional data

B
C
1
6
7

Measuring point number/identification


max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Setting of pressure indicator in pressure units


specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C

Y21

Only the settings for "Y21" can be made in the factory.

2/100

Siemens FI 01 2005

Order code

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for level

Technical specifications

Wetted parts materials

SITRANS P pressure transmitters, DS III FF series for level

High-pressure side:
Seal diaphragm of mounting flange

Stainless steel 316L,


Monel 400, mat. No. 2.4360,
Hastelloy B2, mat. No. 2.4617,
Hastelloy C276, mat. No. 2.4819,
Hastelloy C4, mat. No. 2.4610,
tantalum, PTFE, ECTFE

600 mbar (8.7 psi)

Measuring cell filling

Silicone oil

1600 mbar (23.2 psi)

Process connection

5000 mbar (72.5 psi)

High-pressure side

Flange to DIN and ANSI

Lower measuring limit

Low-pressure side

Female thread -18 NPT and


flange connection to DIN 19213
with mounting thread M10 or
7/ -20 UNF to EN 61518
16

Power supply UH

Supplied through bus

Input
Measured variable

Level

Nominal measuring range

Max. working pressure

250 mbar (3.63 psi)

See "Mounting flange"

Measuring cell with silicone oil filling

-100% of max. span or


30 mbar (0.435 psi) absolute,
depending on mounting flange

Upper measuring limit

100% of max. span

Output

Digital Foundation Fieldbus signal

Separate 24 V power supply neces- No


sary

Physical bus

IEC 61158-2

Bus voltage

Measuring accuracy
Reference conditions

Increasing characteristic
Start-of-scale value 0 bar
Stainless steel seal diaphragm
Mounting flange without tube
Silicone oil filling
Room temperature (25 C (77 F))

Error in measurement (including


hysteresis and repeatability)
- Linear characteristic

0.15%

Not Ex

9 ... 32 V

With intrinsically-safe operation

9 ... 24 V

Current consumption
Basic current (max.)
Classification according to pressure
equipment directive
(DRGL 97/23/EC)

Influence of ambient temperature

- 600-mbar (8.7 psi) measuring


cell
- 1,600 and 5,000 mbar (23.2 and
72.5 psi) measuring cells

0.7%
0.5%
0.45%

With -40 ... -10 C and


+60 C ... +85 C
(-40 ... +14 and 140 ... 185 F)
- 250-mbar (3.63 psi) measuring
cell
- 600-mbar (8.7 psi) measuring
cell
- 1,600 and 5,000 mbar (23.2 and
72.5 psi) measuring cells

Intrinsic safety "i"

Ex II 1/2 G EEx ia/ib IIB/IIC T6

- Permissible ambient temperature

-40 ... +85 C (-40 ... +185 F)


temperature class T4;
-40 ... +70 C (-40 ... +158 F)
temperature class T5;
-40 ... +60 C (-40 ... +140 F)
temperature class T6

- Connection

To a certified intrinsically-safe circuit with maximum values:


FISCO supply unit:
Uo = 17.5 V, Io = 380 mA,
Po = 5.32 W
Linear barrier:
Uo = 24 V, Io = 250 mA,
Po = 1.2 W

- Effective internal inductance/capacitance

Li = 7 H, Ci = 1.1 nF

0.3% / 10 K ( 0.4% / 18 F)
0.27% / 10 K ( 0.4% / 18 F)

IP65

Temperature of medium
Measuring cell with silicone oil filling

Explosion-proof "d"

Planned

Type of protection "n" (zone 2)

Planned

Explosion protection to FM

Planned
Planned

- High-pressure side

pabs 1bar: -40 ... +175 C


(-40 ... +347 F)
pabs < 1bar:-40 ... +80 C
(-40 ... +176 F)

Explosion protection to CSA

- Low-pressure side

-40 ... +100 C (-40 ... +212 F)

Nom. diam.
To EN 1092-1
- DN 80
- DN 100

Design
Weight
To DIN (pressure transmitter with
mounting flange, without tube)

11 ... 13 kg (24.2 ... 28.7 lb)

To ASME (pressure transmitter with


mounting flange, without tube)

11 ... 18 kg (24.2 ... 39.2 lb)

PTB 99 ATEX 2122

- Identification

0.4% / 10 K ( 0.4% / 18 F)

Rated conditions
Degree of protection (to EN 60529)

For gases of fluid group 1 and


liquids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)

Explosion protection

With -10 ... +60 C (14 ... 140 F)


- 250-mbar (3.63 psi) measuring
cell

12.5 mA

Certificates and approvals

Mounting flange

To ASME B16.5
- 3 inch
- 4 inch

Nom. press.
PN 40
PN 16
PN 40
Class 150
Class 300
Class 150
Class 300

Siemens FI 01 2005

2/101

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for level

Dimensional drawings
approx. 30 (1.18)

185
100 (3.94)

138 (5.4)
69 (2.72)

50
(1.97)

15
(0.6)

77 (3)3)

165 (6.5)

51)

54 (2.1)

8
d5
d4

108 (4.25)
Space for rotation
of housing

nxd 2
b
f
1
2
3
4
5
6
8
9
1)
2)
3)

Process connection: Low-pressure side -18 NPT (EN 61518)


Blanking plug
Electrical connection:
- screwed gland M20x1,5 2 ) or
- screwed gland -14 NPT
Terminal side
Electronics side, digital display (longer overall length for cover with window)
Protective cover over keys
Sealing screw with valve (option)
Screw cover safety bracket (only for explosion-proof enclosure,
not shown in the drawing)

51)

41)

Allow approx. 20 mm (0.79 inch) thread length in addition


Not with type of protection "FM + CSA [is + xp]"
92 mm (3.62 inch) for minimum distance to permit rotation without indicator

SITRANS P pressure transmitters, DS III FF series for level, including mounting flange, dimensional drawing, dimensions in mm (inch)

Connection to EN 1092-1
Nom. diam.

Nom. press.

d2

d4

d5

dM

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

24

200

90

18

138

76

72 1)

160

0, 50, 100,
150 or 200

DN 80

PN 40

DN 100

PN 40

20

220

115

18

158

94

89

180

PN 40

24

235

115

22

162

94

89

190

Connection to ASME B16.5


Nom. diam.
3 inch

4 inch

Nom. press.

lb/sq.in.

inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm)

150

0.94
(23.8)

7.5
(190.5)

0.75
(19.0)

5
(127)

3
(76)

2.81 1)
(72)

0.06
(1.6)

300

1.12
(28.6)

8.25
(209.5)

0.87
(22.2)

5
(127)

3
(76)

2.81 1)
(72)

150

0.94
(23.8)

9
(228.5)

0.75
(19.0)

6,19
(157.2)

3.69
(94)

300

1.25
(31.7)

10
(254)

0.87
(22.2)

6,19
(157.2)

3.69
(94)

d: Internal diameter of gasket to DIN 2690


dM: Effective diaphragm diameter

2/102

Siemens FI 01 2005

d2

d4

d5

1)

dM

6
(152.4)

0.06
(1.6)

6.69
(168.3)

0, 2, 3.94,
5.94 or 7.87
(0, 50, 100,
150 or 200)

3.5
(89)

0.06
(1.6)

7.5
(190.5)

3.5
(89)

0.06
(1.6)

7.88
(200)

89 mm = 3 inch with tube length L = 0.

inch (mm)

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for level
Selection and Ordering data

Order No.

Further designs

SITRANS P pressure transmitters


for level

7MF 4 6 3 5 -

Please add "-Z" to Order No. and specify Order code.

DS III FF series

1 7 Y77 - 7777

Rated measuring range


250 mbar
(3.63 psi)
600 mbar
(8.70 psi)
1600 mbar
(23.2 psi)
5 bar
(72.5 psi)
Process connection of low-pressure side
Female thread -18 NPT with flange connection
Mounting thread M10 to DIN 19 213
Mounting thread 7/16-20 UNF to EN 61518

D
E
F
G

0
2

Non-wetted parts materials


Process flange screws Electronics housing
Stainless steel
Stainless steel

Die-cast aluminium
Stainless steel precision
casting

2
3

Design
Standard design
International version, English label inscriptions,
documentation in 5 languages on CD
Explosion protection
without
with CENELEC, Type of protection:
- "Intrinsic safety (EEx ia)"
- "Explosion-proof (EEx d)" 1) (planned)
- "Intrinsic safety and explosion-proof enclosure
(EEx ia + EEx d)" 2) (planned)
- "n (zone 2)" (planned)
with FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof (is + xp)" 1)
(planned)
Electrical connection / cable inlet
Screwed gland M20x1.5
Screwed gland -14 NPT
Display
without (digital display hidden)
with visible digital indicator
with customer-specific digital indicator (setting
as specified, Order code "Y21" required)
Ordering information:
1st order item: Pressure transmitter 7MF4635-...
2nd order item: Mounting flange 7MF4912-...
Example of ordering:
Item line 1:
7MF4635-1EY22-1AB1
Item line 2:
7MF4912-3GE01
Included in delivery of the device:
Brief instructions (Leporello)
CD-ROM with detailed documentation
Sealing plug(s) or sealing screw(s) for the process flanges(s)

1
2

A
B
D
P
E
NC

B
C

Order code

O-rings for process flanges on low-pressure side


(instead of FPM (Viton))
PTFE (Teflon)
FEP (with silicone core, approved for food)
FFPM (Kalrez, compound 4079)
NBR (Buna N)

A20
A21
A22
A23

Sealing screws
-18 NPT, with valve in material of process flanges

A40

Rating plate inscription


(instead of German)
English
French
Spanish
Italian

B11
B12
B13
B14

English rating plate


Pressure units in inH2O or psi

B21

Manufacturer's test certificate M


to DIN 55350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10204-3.1B

C12

Factory certificate
to EN 10204-2.2

C14

Type of protection IP68

D12

Use on zone 1D / 2D
(only together with type of protection "Intrinsic safety
(EEx ia)"

E01

Use at zone 0
(only together with type of protection "Intrinsic safety
(EEx ia)"

E02

Interchanging of process connection side

H01

Additional data
1
6
7

Measuring point number/identification


max. 16 characters, specify in plain text:
Y15: ...........................................

Y15

Measuring point text


max. 27 characters, specify in plain text:
Y16: ...........................................

Y16

Setting of pressure indicator in pressure units


specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG,
psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
*) Reference temperature 20 C

Y21

Only the settings for "Y21" can be made in the factory.

1) Without cable gland, with blanking plug


2) With enclosed cable gland EEx ia and blanking plug

Siemens FI 01 2005

2/103

SITRANS P measuring instruments for pressure


Transmitters for pressure, absolute pressure, differential pressure, flow and level
DS III FF series for level

Selection and Ordering data

Order No.

Further designs

Mounting flange

7MF 4 9 1 2 -

Please add "-Z" to Order No. and specify Order code.

Directly fitted to pressure transmitter


SITRANS P (converter part) for level,
for DS III FF series

3 7777 -

Spark arrestor
for mounting on zone 0 (including documentation)

A01

Manufacturer's test certificate M


to DIN 55350, Part 18 and to ISO 8402

C11

Acceptance test certificate B


to EN 10204-3.1B

C12

Vacuum-proof design
(for use in low-pressure range)

V04

Calculation of span of associated pressure


transmitter
(enclose filled-in questionnaire with order)
Note:
Suffix "Y01" required with pressure transmitter

Y05

Connection to EN 1092-1
Nom. diam.
Nom. press.
DN 80
PN 40
DN 100
PN 16
PN 40
Connection to ASME B16.5
Nom. diam.
Nom. press.
7.62 cm
Class 150
Class 300
4 inch
Class 150
Class 300
Other version
Add Order code and plain text:
Nominal diameter: ...; Nominal pressure: ...

D
G
H

Q
R
T
U
Z

J1Y

Wetted parts materials


Stainless steel 316L 1)
- Coated with PFA
- Coated with PTFE
- Coated with ECTFE

A
D
E0
F

Monel 400, mat. No. 2.4360


Hastelloy B2, mat. No. 2.4617
Hastelloy C276, mat. No. 2.4819
Hastelloy C4, mat. No. 2.4610
Tantalum

G
H
J
U
K

Other version
Add Order code and plain text:
Wetted parts materials: ...
Sealing face, see "Technical data"

Tube length
without
50 mm
(1.97 inch)
100 mm
(3.94 inch)
150 mm
(5.90 inch)
200 mm
(7.87 inch)
Other version:
Add Order code and plain text:
Tube length: ...
Filling liquid
Silicone oil M5
Silicone oil M50
High-temperature oil
Halocarbon oil (for O2 measurements)
Vegetable oil
Glycerin / water2)
Other version
Add Order code and plain text:
Filling liquid: ...
1) For vacuum on request
2) Not suitable for use in low-pressure range

2/104

Siemens FI 01 2005

777

K1Y

0
1
2
3
4
9

L1Y

1
2
3
4
5
6
9

M1 Y

Order code

You might also like