You are on page 1of 13

Ceiling and Cabinet Fans

Accurex, LLC certifies that the XCR models shown


herein are licensed to bear the AMCA seal. The ratings
shown are based on tests and procedures performed
in accordance with AMCA Publication 211 and AMCA
Publication 311 and comply with the requirements of the
AMCA Certified Ratings Program.

Models XCR and XIR are listed electric fans


(UL/C-UL US 507). Ceiling Exhaust Fans are also
UL Listed for above bathtub/shower with GFCI
branch protected circuit. File no. E33599.

* UL is optional and must be specified.

Accurex, LLC certifies that the XIR models shown


herein are licensed to bear the AMCA seal. The ratings
shown are based on tests and procedures performed
in accordance with AMCA Publication 211 and comply
with the requirements of the AMCA Certified Ratings
Program.

[ 42 ]

Ceiling and Cabinet Fans


Model Overview

Great things come in small packages, as do our ceiling fans (model XCR) and cabinet fans (model XIR). Be assured
when you buy any Accurex product, you are getting a quality product at a competitive price. We offer one of the
most comprehensive ceiling and cabinet exhaust fan line in the commercial market. In fact, we guarantee our ceiling
and cabinet fans with a three (3) year warranty. You will also receive these additional benefits with an Accurex ceiling
and cabinet exhaust fan:
UL Listed electric
Low sound and compact size
Competitive price
Broadest performance selections in the industry

Model Number Code


The Model Number Code is designed to completely identify the fan. The correct code letters must be specified
to designate belt or direct drive, and roof or wall mounted configurations. The remainder of the model number
is determined by the size and performance.

XCR - A

50 FL

Model
XCR - Ceiling Exhaust Fan

Light Options:

XIR - Cabinet Inline Fan

L - Fan/Light (Incandescent) Combination


FL - Fan/Light (Fluorescent) Combination

Level of Construction
A - Premium unit, lowest sound, insulated housing

Nominal cfm at 0.10 in. wg static pressure

B - Deluxe unit, low sound, low profile


C - Standard unit, lowest profile, inexpensive

[ 43 ]

Ceiling and Cabinet Fans


Model Comparison
XCR. XIR.

XCR fans are designed for ceiling mounted applications. XIR fans are designed for inline
remote mounted applications.

XCR-A
The XCR-A is a premium ceiling fan. It is in the top of its class when it comes to meeting
sound requirements.
Sound levels as low as 0.7 sones
Profile as low as 1012 inches (26.67 cm)
Air volume as high as 1,600 cfm (2,718 m3/hr)
UL Listed for above bathtub/shower with GFCI branch protected circuit

XCR-B
The XCR-B is a deluxe ceiling fan compact enough for almost any application. If quiet is
what you are after, this fan will accommodate your needs.
Sound levels as low as 1.7 sones
Profile as low as 61516 inches (17.62 cm)
Air volume as high as 200 cfm (340 m3/hr)
UL Listed for above bathtub/shower with GFCI branch protected circuit

XCR-C
The XCR-C is our economy ceiling fan designed for light commercial applications.

Sound levels as low as 2.9 sones

Profile as low as 358 inches (9.21 cm)

Air volume as high as 50 cfm (85 m3/hr)

UL Listed for above bathtub/shower with GFCI branch protected circuit

XIR-A
The XIR-A is a premium inline fan. It outperforms the competition and is preferred by
specifying engineers.

Sound levels as low as 0.8 sones

Profile as low as 1012 inches (26.67 cm)

Air volume as high as 3,800 cfm (6,456 m3/hr)

UL/C-UL US Listed

XIR-B
The XIR-B is a compact deluxe inline fan. It is designed to fit in small remote quarters.

Sound levels as low as 2.0 sones

Profiles as low as 61516 inches (17.62 cm)

Air volume as high as 190 cfm (323 m3/hr)

UL/C-UL US Listed

[ 44 ]

Ceiling and Cabinet Fans


Standard Construction Features
XCR-A.

1 Spring Loaded Aluminum Backdraft Damper


Eliminates rattling or unwanted backdrafts
2 Outlet Square and round outlets are field rotatable
from, horizontal to vertical discharge
3 Power Assembly Removes quickly for
maintenance, or conversion from horizontal to
vertical discharge

Electrical Junction Box Large for easy wiring

Attractive Designer Grille Concealed attachment


screws securely fasten grille to housing, for quiet
and rattle-free operation

10 Mounting Brackets Fully adjustable for multiple


installation conditions
11 Housing Embossed galvanized steel for rigidity

4 External Electrical Access Eliminates removing


motor pack, saving installation time

12 Motors All motors are compatible for use


with speed controls and have thermal overload
protection. Domestic and international applications
are available.

5 Electrical Knockouts (horizontal or vertical)


Eliminates drilling holes
6 Acoustic Insulation Absorbs sound

50 cycle, 220v, and 240v options

7 Disconnect Servicing is quick and safe

60 cycle, 115v, 208v, 220v, 230v, and


277voptions

2
4

1
7

11

12

10

9
[ 45 ]

Ceiling and Cabinet Fans


Standard Construction Features
XCR-B.

1 Aluminum Backdraft Damper Prevents


unwanted backdrafts

8 Mounting Brackets Fully adjustable for multiple


installation types

2 Round Standard Outlet (4 or 6 in.) Versatile for


quick and easy connections

9 Housing Embossed galvanized steel for rigidity


and low profile for height restricted areas

3 Power Assembly Removes quickly for


maintenance

10 Motors All motors are compatible for use


with speed controls and have thermal overload
protection. Domestic and international applications
are available.

4 Electrical Access (vertical) Eliminates


drillingholes

50 cycle, 220v, and 240v options

5 Disconnect Servicing is quick and safe

60 cycle, 115v, 208v, 220v, 230v, and


277voptions

6 Electrical Junction Box Large for easy wiring


7 Attractive Designer Grille Concealed attachment
screws securely fasten grille to housing, for quiet
and rattle-free operation

9
3

10

5
6
4

[ 46 ]

Ceiling and Cabinet Fans


Standard Construction Features
XCR-C.

1 Plastic Backdraft Damper - Prevents


unwantedbackdrafts

6 Mounting Brackets - Adjustable for several


installation types

2 Round Outlet - 3-inch diameter allows quick and


easy connections

7 Housing - Galvanized steel for rigidity and low profile


for height-restricted areas

3 Power Assembly - Removes quickly for maintenance

8 Motors - Compatible for use with speed controls.


Thermal overload protection

4 Disconnect - Servicing is quick and safe

60 cycle, 115v

5 Polymeric Grille - Quickly snaps into place

1
7
5

6
2

4
8

[ 47 ]

Ceiling and Cabinet Fans


Standard Construction Features
XIR-A.

9 Access Panel Gain easy access to internal


components once installed

1 Spring Loaded Aluminum Backdraft Damper


Eliminates rattling or unwanted backdrafts
2 Outlet Square and round outlets are field rotatable
from horizontal to vertical discharge

10 Mounting Brackets Fully adjustable for multiple


installation conditions

3 Power Assembly Removes quickly for


maintenance, or conversion from horizontal to
vertical discharge

11 Housing Embossed galvanized steel for rigidity

4 External Electrical Access Eliminates removing


motor pack, saving installation time

12 Motors All motors are compatible for use


with speed controls and have thermal overload
protection. Domestic and international applications
are available.
50 cycle, 220v, and 240v options

5 Electrical Knockouts (horizontal or vertical)


Eliminates drilling holes
6 Acoustic Insulation Absorbs sound
7 Disconnect Servicing is quick and safe
8 Electrical Junction Box Large for easy wiring

60 cycle, 115v, 208v, 220v, 230v, and


277voptions
13 Inlet Duct Collar Allows for the ductwork to slide
over the duct collar to be fastened for faster and
easier installation of the ductwork.

5
2

8
6
13

4
7

1
3

12

11

10
9

[ 48 ]

Ceiling and Cabinet Fans


Standard Construction Features
XIR-B.

1 Aluminum Backdraft Damper Prevents


unwanted backdrafts

8 Housing Embossed galvanized steel for rigidity


and low profile for height-restricted areas

2 Round Standard Outlet (6 in.) Versatile for quick


and easy connections

9 Motors All motors are compatible for use


with speed controls and have thermal overload
protection. Domestic and international applications
are available.

3 Power Assembly Removes quickly for


maintenance

50 cycle, 220v, and 240v options

4 Electrical Access (vertical) Eliminates


drillingholes
5 Disconnect Servicing is quick and safe
6 Electrical Junction Box Large for easy wiring
7 Mounting Brackets Fully adjustable for multiple
installation types

60 cycle, 115v, 208v, 220v, 230v, and


277voptions
10 Inlet Duct Collar Allows for the ductwork to slide
over the duct collar to be fastened for faster and
easier installation of the ductwork.

2
1

4
8
6
7

10

[ 49 ]

Ceiling and Cabinet Fans


Options and Accessories
XCR. XIR.

Grille Options
Designer - Standard Grille
Decorative - Lighted and non-lighted
Aluminum - White enamel finish
Stainless Steel - Polished stainless steel finish

Double-Wide Fans
Available for applications requiring
700 cfm or greater. Double-wide
fans have two double-width
forward curved wheels, which are
housed in separate scrolls, and
driven by a single motor.

Round Duct Connection


Standard - Sizes A50, A70, and A90
Round Duct Adapter
Optional - Sizes A110 through A510
Exclusive Electrical Wiring Feature
Accurex XCR-A models are the only fans of this type with an
electrical access cover located on the housing exterior. This
feature permits external wiring without removing the power
assembly, saving installation time and cost.
Vertical Discharge
Exhaust outlet duct may be installed in the optional vertical
position. The power assembly must be rotated to match the
duct adapter position.

Contractor 4 Paks
Save installation time and labor
by installing the housing first, then
installing the internal components
after the sheetrocking, plastering
and finishing is done.
Housings are packaged in one
box, power assembly and grille
are packaged in another box
Components are shipped to
coincide with the phase of your
project

Light Options
Accurexs fan/light combination includes a prismatic or frosted lens, and compact fluorescent or incandescent
lamps. Our unique light box is manufactured with a reflective material to increase the light given off by either type of
lamp. UL Listed for above bathtub/showers with GFCI branch protected circuit.
Available on Sizes 50 - 125
Prismatic Lens

Frosted Lens
The frosted lens option is a
traditional design which lets
approximately 80% of light through
the lens. The lens may be easily
removed to replace light bulbs.

The prismatic lens design provides


approximately 25% more light than a
traditional frosted lens. The lens may be
easily removed to replace light bulbs.

Compact Fluorescent Lamps (CFL)

Quick start bulbs


Reflective light box
Produce 90% less heat
Lower energy costs
Two-13 watt CFL bulbs equals
100 watts of incandescent
light(included)

Incandescent Lamps
Dimmable
Reflective light box
Low first-cost light
One bulb provides up to 100 watts
of light (by others)

[ 50 ]

Ceiling and Cabinet Fans


Options and Accessories
XCR. XIR.

Speed Controls
Speed controls may be used on model XCR and XIR fans for manual adjustment of the fans performance (for final
system balancing) or to control the fans output in confined spaces, such as conference or meeting rooms. The
fan can be adjusted to 60% of design airflow with a speed control. This reduction in airflow and fan speed is also
accompanied by a reduction in noise level. Solid state speed controls are available for a range of applications up
to 15 amps. Speed controls can be used to operate more than one fan if the combined total amperage of the fans
does not exceed the control rating.
Model 5WSSC - For use with shaded pole and PSC motors.
Available shipped loose or mounted internal or external.
Rated for 115 - 127v, 5 amp
UL Listed
Require a 2x4 handy box
Model 5W240 - For use with shaded pole and PSC motors.
Available shipped loose or mounted internal or external.
Rated for 220 - 240v, 5 amp
UL Listed
Requires 2x4 handy box
Model 5W277 - For use with shaded pole and PSC motors.
Available shipped loose or mounted internal or external.
Rated for 277v, 5 amp
UL Listed
Requires 2x4 handy box

FULL VOL TAGE

Model 8WSSC - For use with shaded pole and PSC motors.
Available shipped loose or mounted internal or external.
Rated for 220 - 240v, 8 amp
UL Listed
Requires 2x4 handy box

RED

Dotted line indicates


for use with 10W
switch only .

BLACK

SWITCHED FULL VOLTAGE

AUX
DEVICE

WHITE
SPEED CONTROL

Model 10WSSC - For use with shaded pole and PSC motors. Available
shipped loose or mounted internal or external.
Rated for 115 - 127v, 10 amp
UL Listed
Requires 4x4 handy box

VARIABLE
VOLTAGE

120 VAC

FAN

Model 15WSSC - For use with shaded pole and PSC motors.
Available shipped loose or mounted internal or external.
Rated for 115 - 127v, 15 amp
UL Listed
Requires 4x4 handy box

Switches
Switches may be used on models XCR and XIR fans to enable manual control of your fan or fan/light combination.
There are several options to fit your application.
NEMA-1 - Single pole rocker switch assembly.
Rated for 115v, 15 amp, 1/2 hp
UL Listed

EXTERNAL JUMPER

Model MS-16 - Single pole rocker switch


assembly with cover and pilot light.
LOAD

Rated for 115v, 15 amp, 1/2 hp


UL Listed

LOAD

NEMA-1 - Two pole rocker switch assembly.


Rated for 220/230/240/277v, 20 amp, 2 hp
UL Listed
Requires a 2x4 handy box

[ 51 ]

Ceiling and Cabinet Fans


Options and Accessories
XCR. XIR.

Time Delay Switch


Time delay switches save energy by automatically turning off equipment. They may be used with models XCR
and XIR fans and fan/light combinations, for extended operating time of fan. Time delay switches act in the same
manner as a standard switch, however, there is a delay of 1 to 60 minutes after the it has been turned off.
Model GTD - Single-switch controls both fan and
light. Available shipped loose.
Silent operation
UL Listed

115 VOLT AC (HOT)


60 CYCLE

BLACK

(500 Watt Max)


LIGHT

BLUE

Rated for 115v


Requires 2x4 handy box

(7.5 Amps Max)


FAN MOTOR
RED

(NEUTRAL)
WHITE

Motion Detectors
Motion detectors may be used with models XCR and XIR fans, or fan and light combinations. Motion detectors use
a passive infrared motion detector that will automatically turn on the fan when a change in temperature is sensed.
They have a viewing area of 180 degrees, however, they must be placed in the line-of-sight. They also have an
adjustable time delay shutoff setting of 1 to 20 minutes.
Grille Motion Detectors
(Model MDW) are available
on models up through size
XCR-A390 and XCR-B200.
For use on fan or lights.
Available shipped loose.

Black

Black
White
Red

Motion Sensor

Hot

Hot

Green
Neutral

Gnd.

Rated for 115v


UL Listed
Requires 2x4 handy box

Red
Neutral

Fan Motor and/or


Light

Load
(12.5 Amps Max.)

Wall Mount

Black
Green
White

Ground

Grille Mount

Transformers
Transformers are available for applications requiring voltage reduction. Selection is based on motor amperage. All
transformers are shipped loose.
Model T-2.0 - UL Listed
Rated for 230/277v to 115, 2 amps
Model T-4.3 - UL Listed
Rated for 230/277v to 115, 4.3 amps
Model T-6.5 - UL Listed
Rated for 230/277v to 115, 6.5 amps
Model T-8.6 - UL Listed
Rated for 230/277v to 115, 8.6 amps

[ 52 ]

277 V SUPPLY
SWITCH BOX
BLK

BLK

BLK

H1

H2

H3

277V TO 115V TRANS.


750 VA
X1
RED

X2
RED

SWITCH

115 V MOTOR

Ceiling and Cabinet Fans


Options and Accessories
XCR. XIR.

Ceiling Radiation Dampers


The Accurex XCR-A and XCR-B
ceiling radiation dampers are UL
Classified, rated at three to four hours
fire resistance, and are available on all
XCR-A and XCR-B fans and fan/light
combinations. This design saves space
by allowing the damper to mount directly beneath
the fan.

XCR Model CRD


A50 - A190
310
B50 - B200
320
A200 - A390
A410 - A510
350
A710 - A780
A - 700
700
A900 - A1550 360

Length
1312

Width
1118

Height
3

1438

1214

18716

141516

24316
24316

1214
141516

3
3

All dimensions shown in inches.


Add an L to all CRD models if fan & light combo is used.

Filters
Fans used in most applications, even where air is not excessively dirty, will collect airborne dirt on wheels and
motors over time. Accumulations of dirt on the fan wheel will sharply reduce performance and cause imbalance. Dirt
buildup on the motor can cause it to overheat. All of these conditions will shorten the life of the fan. To help reduce
this accumulation, washable aluminum mesh filters are available to trap dirt before it enters the fan. These filters
should be regularly cleaned to maintain performance. The Filter Loss Chart shows the effect the filter will have on
performance. To determine the added resistance, divide the desired cfm by the filter area (ft2). This will give FPM.
Use this with the filter loss chart to get the added resistance. In addition to reducing dirt accumulations on the motor
and wheel, filters also reduce sound levels.
Filter Loss Chart
.24
.22
Mesh
Filter

.20
.18

XQP
Grille

Filter
Area
(ft2)
.620
.785
1.319
1.797

All dimensions shown in inches. *Aluminium or Stainless Steel Grille.

[ 53 ]

Resistance (in w.c.)

Filter Model
XCR Model
Designer
*Metal
Grill
Grille
XCR-A50 - A190
F-200
F-210
XCR-B50 - B200, A200 - A390
F-200
F-220
XCR-A410 - A510
NA
F-250
XCR-A710 - A780
XCR-A900 - A155
NA
F-260

.16
.14
.12
.10
.08
.06
.04
.02
.00

3
4
5
6
Velocity (fpm x 100)

Ceiling and Cabinet Fans


Options and Accessories
XCR. XIR.

The following chart shows which options and accessories are available on Accurexs ceiling and cabinet fans.
Options and Accessories
Grille Options
Round Duct Connection

XCR-A
Standard

XCR-B
Standard

XCR-C

XIR-A

XIR-B

Standard

Standard

Optional

Standard

Round Duct Adapter

Optional

Optional

Electrical Wiring Feature

Standard

Standard

Vertical Discharge

Optional

Optional

Double-Wide Fans

Optional

Optional

Contractor 4 Paks

Optional

Prismatic Lens

Optional

Optional

Compact Fluorescent Lens

Optional

Optional

Frosted Lens

Optional

Optional

Incandescent Lamps

Optional

Optional

Model 5WSSC

Optional

Optional

Optional

Optional

Optional

Model 5W240

Optional

Optional

Optional

Optional

Model 5W277

Optional

Optional

Optional

Optional

Model 8WSSC

Optional

Optional

Optional

Optional

Model 10WSSC

Optional

Optional

Optional

Optional

Optional

Model 15WSSC

Optional

Optional

Optional

Optional

Optional

NEMA-1

Optional

Optional

Optional

Optional

Model MS-16

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Model T-2.0

Optional

Optional

Optional

Optional

Optional

Model T-4.3

Optional

Optional

Optional

Optional

Optional

Model T-6.5

Optional

Optional

Optional

Optional

Optional

Model T-8.6

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Model WC (Round Connection)

Optional

Optional

Optional

Optional

Optional

Model WC (Square/Rect. Connection)

Optional

Optional

Optional

Optional

Optional

Model WL

Optional

Optional

Optional

Optional

Optional

Model BVE

Optional

Optional

Optional

Optional

Optional

Model RDC

Optional

Optional

Optional

Optional

Optional

Model RJ (Pitched Roof Curb)

Optional

Optional

Optional

Optional

Optional

Model RCC-7

Optional

Optional

Optional

Optional

Optional

Model GRS

Optional

Optional

Optional

Optional

Optional

Model RFC-7

Optional

Optional

Optional

Optional

Optional

Model GRSF

Optional

Optional

Optional

Optional

Optional

Hanging Vibration Isolators

Optional

Optional

Optional

Optional

Optional

Light Options

Speed Controls

Switches

Time Delay Switch


Model GTD
Motion Detectors
Model MDW
Transformers

Dampers
Ceiling Radiation Damper
Filters
Filters
Wall Discharge

Roof Discharge Accessories

[ 54 ]

You might also like