INSTRUCTION MANUAL

Dosing System MID-MDS

Version 4 Startinputs, Individual starts

Software VER 2.00

Hardware Housing MDS-30


Terminal connectors QB-173
QB-172
QB-170
Counter / Valve card LS-23
Master card DR-11

Converter card UV-12

Terminal ( Software ) V200

Bopp & Reuther Messtechnik GmbH


Am Neuen Rheinhafen 4
D-67346 Speyer
www.bopp-reuther.de A-EN-05802-00A
INSTRUCTION MANUAL

Installation and operation of the

MODULAR DOSING SYSTEM SERIES MID- MDS

1.Application:

The Modular Dosing System MID-MDS is used on both linear and rotating filling machines, where high
accuracy/repeatability is required. The products must have a minimum conductivity of approx 1 µS/cm. The
minimum dosing time achieved to date is approx. 0.1 sec.
Magnetic Inductive Flow Meters series MID have no moving parts, and therefore do not apply any "work" to
the product which could cause changes to the fluid structure. This also enables CIP/SIP procedures to be
carried-out both easily and quickly.

2. The dosing system MID-MDS consists of the following components (Fig.1):

- magnetic inductive flow meter series MID


with standard frequency field design, with integral pre-amplifier

- dosing control ( electronics ) series MDS:

* converter card type UV- 12 * master card type DR- 11


with integral pulse output
* counter/valve card type LS- 23 * LAUER operator terminal

* housing for card installation: panel housing type MDS-30 ( 30 TE ), or


panel housing type MDS-49 ( 49 TE ), or
19" rack mounting type MDS-84 ( 84 TE )

meter 6
QB-173

cable with plug CONVERTER


CONVERTER
CONVERTER
CONVERTER 6
meter 1 CONVERTER 5
cable with plug
electronics MDS-30/49/84
CONVERTER 4
QB-173

CARD 3
UV-12 2
1

CPU parallel input/output port


QB-181

NAMUR
pulse inputs
COUNTER/VALVE CARD LS-23
12 valve power modules dual-port-RAM selection of the
1
counter/valve cards
pre-and final closing
of the valve

QB-172

12
parallel input/output port

MASTER CARD DR-11


serial 1 serial 2 optocouplers
24 VDC
24 VAC

QB-xxx

QB = Adapter card Terminal Input/Outputs


LAUER
PC/SPS
3. A filling system/installation generally consists of (Fig.2):

storage tank terminal


type LAUER

magnetic
inductive elektronics
flow meter measuring cable type MID-MDS
type MID-MDS
valve signal
dosing valve
start signal
receptacle

Fig.2

Systems with very short dosing times ( min. 0.1 to some sec. ) need a storage ( buffer ) tank-see Fig.2- the
level of which must be kept more or less constant, e.g. by using a level control system, which automatically
opens and closes the feed line to the storage tank. This arrangement supplies a dosing curve ( lapse ) as
shown in (Fig.3):

v= flow velocity ( m/sec ) 1- stage valve closing


v
At time A the filling machine starts the batch process and the
finalbatch volume dosing valve opens. The magnetic flow meter measured the
product; the sensed signal is send to the dosing control and also
excess volume to the preset counter. At the end of the batch (B) the dosing
valve receives the signal to close. Because of delay time in the
system ( mainly the valve ) a certain excess volume passes the
dosing valve until it is closed and the batch process is finished
(C).
A B C t

v= flow velocity ( m/sec )


v 2-stage valve closing
prebatch volume
It is possible to decrease the excess volume if a 2-stage valve
finalbatch volume closing is used. If the valve receives the prebatch signal ( B ),
then the valve closes to a interposition.
excess
If the valve receives the finalbatch signal ( C ), then the valve
volume closes completely.
These kind of valve closing should also be used if
- the meter size is > DN 20 or
A B C t
- the batch is > 0.5 l / sec.
- the velocity in the pipe is > 5 m/sec.
4. The components of a filling system should meet the following requirements:

a) storage tank ( no pressure, head of liquid only )

The tank dimension ( dia.,height ) should be such that a batch process ( one filling ) only causes a very small
level variation ( decrease ). In the event of a large variation, the head ( gravity ) decreases rapidly, the
excess volume is altered ( Fig.4) and both accuracy and reproducibility vary.

start start

v v
batch end batch end

excess
excess-
volume
volume
A B

dosing time of 1.st filling t dosing time of the following filling t


Fig.4

Due to the decreasing head of liquid, the flow velocity and the flow rate decrease, resulting in the dosing
time becoming longer and longer ! This effect should be avoided if the dosing time is to be kept constant.

To keep the filling times constant, the liquid level head should be kept within 5% .

At bigger meter sizes (> DN 15) the


liquid level must be more then 30 cm.
If the level < 30 cm, Vortex-effects are
possible and resulting accuracy vary.
( A ).

To prevent vortex effects a build -in


straightener is advantageous.

Very important is the position of the


product line in the tank. The outlet of
the pipe must be under the liquid level (
B ). In other case, air bubbles are in the
product and resulting accuracy vary.

A B

b) piping

Whenever possible rigid metallic piping between storage tank and dosing valve should be installed. If flexible
hoses are used, hydraulic vibrations could disturb the batch processes. The piping should be of the same size
( DN;inner dia. ) as the magnetic inductive flow meter in order that the system can be deaerated easily.
valve closes Hydrau
lic vibrations are be created, if e.g.
C diaphragm, hoses or buffer tanks are
existing.
The energie in the liquid is decreased
with the oscillation of the liquid.
start
If the velocity cross the creeping flow
( B ), the pulse output in the converter
creeping flow
start
card is switched off.
A B
If a new start pulse is comming during
oscillation, the velocity in the pipe
increased ( C ).

If hoses are used, then the hoses must be metal cased.

c) dosing valve

The dosing valve is very important for the accuracy/reproducibility of the dosing system.
Attention should be paid to the following parameters:

c1) closing time: the closing time of the valve has to be in a certain ratio to the dosing
time ( A to B ); the shorter the dosing time the shorter the valve closing time.

Guideline:

<<< the valve closing time should be not more than 10% of the dosing time >>>

If it is more than 10%, the dosing control is only able to register the size of the excess volume, but will not be
able to react to it ( i.e. compensate/correct it for the next filling ). This effect can only be avoided by using a
two-stage shut-off ( two valves ), where the 2.nd ( final ) stage can compensate/correct alterations of the 1.st
( pre- ) stage.

c2) power supply: whenever possible a DC supply should be used to avoid the influence of the shape of
sine waves of the AC supply. This is especially if the valve closes with voltage; the valve starts to close
when the sine wave has exceeded the starting voltage; in the worst case this can take 10 ms ( 50 Hz field )
and so cause variations of the batched quantity ( in accuracies ).

c3) dosing valve: it is important that only a small volume is


displaced during the closing procedure. The displaced volume
is part of the measured quantity and thus influences the
accuracy and reproducibility of the complete dosing system. It
should therefore be kept as constant as possible! An instability
of the displaced volume can effect the accuracy of systems
where small quantities are dosed. Diaphragm valves with
metallic body are recommended, where a diaphragm of a
synthetic material ( plastic ) is oppressed onto a metallic edge.
This design has another positive effect: fruit particles and
similar solids to be dosed are squeezed off the valve seat.

Diaphragm valve type 625 ( GEMÜ )


5. Description of the components

a) magnetic inductive flow meter series MID has an integrated and detachable pre-ampifier. The coils for the
magnetic field requires a 24 VAC power supply.the cable for interconnection of the meter and the converter card is
approx. 5 m long ( if a length of more than 5 m is required ( max. 200 m ), an extension cable of same type is
admissible ). In the event of a malfunction the pre-amplifier can be detached and replaced; no calibration of the
replacement is required! The pre-amplifier is connected via plug and socket. The meter can be installed either
horizontally or vertically. Vertical installation is preferred for better deaeration; and also depositsare less likely to be
trapped in the meter. In the case of horizontal installation the electrodes must be in horizontal position, i.e. the
pre-amplifier must be above or underneath-but not beside- the meter body. If the meter is used together with a
converter card UV-12 the flow direction ( right to left/left to right or from below to above or vice versa ) of the meter
is insignificant. The UV-12 switches automatically to the given flow direction and measurement can be started
immediately.

Cables for power and signales


It´s not allowed to install the meter or the electronik in an area with strong magnetic fields. The Measuring cable
must be install separatly from cables with power or controlsignals. The best solution is the installation for the
measuring cable in a grounded pipe of metal.

E
D

Note : Other connectors on request


Dimension of flow meter with sanitary connectors DIN 405

diameter connector A B C D E actual power current weight


DN DIN 405 mm mm mm mm mm W A kg
------------------------------------------------------------------------------------------------------------------------------------------------------
10 RD 28x1/8 80 150 60 60 155 4 0,3 3,5
15 RD 34x1/8 80 150 60 60 155 4 0,3 3,5
20 RD 44x1/6 80 150 60 60 155 4 0,3 3,5
25 RD 52x1/6 120 190 80 75 185 5 0,4 7,5

Dimension of flow meter with steril connectors NAUE (ISO)

diameter connector A B C D E actual power current weight


DN DIN 405 mm mm mm mm mm W A kg
-----------------------------------------------------------------------------------------------------------------------------------------------------
10/12 RD 27x1/10 80 150 60 60 155 4 0,3 3,5

Dimension of flow meter with TRI CLAMP ISO 2852

diameter connector A B C D E actual power current weight


DN mm mm mm mm mm W A kg
-----------------------------------------------------------------------------------------------------------------------------------------------------
40 2" 120 190 80 75 185 5 0,4 7,5

Note : Other connectors on request

Measuring cable

The measuring cable is a standard cable to DIN series LIYY- LIYCY) with two shielded and four unshielded

colour signal voltage core


white measurement 0-50 mVAC shielded
+/- 2 VDC
brown reference voltage 2 hasta 4 VAC shielded
yellow power supply for + 15 VDC unshielded
green pre-amplifier - 15 VDC
red and blue power supply for 24 VAC unshielded
the coils

Fuses for the meter ( mounted onto the terminal adapter QB-173)

------------------------------------------------------------------------------
meter size 24 VAC
-----------------------------------------------------------------------------
DN 10 0.4 A
DN 15 0.4 A
DN 20 0.4 A
DN 25 0.6 A
DN 40 0.6 A
-----------------------------------------------------------------------

Quick-operating fuses must not be used


Installation guideline for transmitter
Inlet/Outlet

For a optimum flow profile it must be installed flow straightener behind and in front of the meter.This can be be
realized. with straight pipes in the upstream- and downstream pipework.
The upstream pipework must be 5 x DN and the downstream pipework must be 3 x DN. It´s not allowed to install
any kind of devices upstreames. It´s forbitten to install in front of the upstream pipework devices which produced
effects like spin or vortex, e.g. space bend, butterfly valves or slider. Any regulation devices must be installed
behind the meter.
Inclinations must be rotational symetrical and the angle should be < 8 °.
The upstream-,downstream pipework and the meter must have the same diameter !!

Length of the upstream-and downstream


flow direction pipework for the meter ( mm ) :

DN upstream downstream
D

3D downstream 10 50 30
5D upstream pipework pipework 15 75 45
20 100 60
25 125 75
32 160 100
40 200 120

Ground connection for the transmitter

The transmitter don´t need additional ground connections. Since the transmitter use the pipe potential as
reference, the upstream-and downstream pipe must be on ground.
The installation of the meter in plastic pipes is not allowed.

The power supply 24 VAC should be also on ground.

Mounting position of the transmitter

It must be insure, that the meter tube is allways completely filled during measuring and is protected against
asymetric formation of deposits. The vertical position is preverred, since it is simple to make the pipe airfree.

Is the meter is installed horizontal, then it must be insure, that


the electrode axis is also horizontal.

Pipework must be supported adjacent to the meter and


connections and provide 3° slope for draining..

Electrode axis If the electrode axis is vertikal, then air bubbles can be isolate
the electrical connection between the electrodes and the
product.
In this case the output signal is undeclared

Laying of the measuring cable

It´s forbitten to install the meter in areas with strong magnetic fields. The measuring cable must be lay separately
from power cables and control cables.
To lay the measuring cable in grounded metal pipes is recommended. Measuring cables can be routed together
with other measuring cables.
Installation guideline for the electronics
General:

It is forbitten to install the electronics in areas with strong magnetic fields. The wiring must be depending from the
function of the cables :

cables for signals e.g. start, error


cables for control e.g. cable for control the diaphragm valves
cables for measuring e.g. measuring cable between the meter and teh electronics
cables for power e.g. 24 VDC, 24 VAC , power for motors

Cables for signals or cables for control can be routed together to a multiple cable.

Measuring cable must be routed with the same cable typ. It is not allowed to bring together several measuring
cables to one shielded cable .

If it is necessary to lengthen the measuring cable, then the terminals for the measuring cable must be separate
from terminals with power. In general the same prinziple as for the cable is valid: the terminals must also be
separate depending from their function.

Heat development

The produced energie from the electronics must be undisturbed left the housing. It must be insure, that air
circulation is possible. All about the housing ( excluding the front plate ) must be a distance of min. 10 cm to other
objects. To take off any cable on the top of the housing is not permissible.
If several housings are installed, then the same principle is valid.

If fans are used, the distance can be reduced.


One fan is necessary for two housings. The width of the fan
module should be the width of the housing.
10 cm

If the fan is only installed for air circulation, then it is important to


know, that the temperature in the housing can be increased.
10 cm

10 cm
If the inside air is exchanged with the air outside of the housing,
then a dry air is necessary.
For air circulation with the outside air please ask a manufacturer
10 cm
about special components for installation in a panel cabinet.

Installation of 2 panel housings in a cabinet

Power supply

The installation of the cable for power supply 24 VDC/ 24 VAC must be laid star-shaped to each terminal
connector card QB 172 ( see B 407.4-11 D page 1 ).

Note : The dimension of the wire cross section for 24 VDC must be considering also the current for the
solenoid valves
Technical data

Transmitter

General

Nominal diameter :DN 10, 15, 20, 25, 32, 40

Pressure max. in bar : Sanitary connector PN 10


Steril connector PN 16 Other connectors on request
Tri-Clamp PN 16
NEUMO flanges PN 16

Minimum Conductivity : 1µS/cm

Mounting position : vertical, if horizontal cannot be avoided, then the electrodes must be in
horizontal position. The pipe must be completely filled with product.

Mounting length : DN 10 to 20 : 150 mm


DN 25 to 40 : 200 mm

Measuring cable lenght : max. 250 m

Any extension of the cable built onto the transmitter is possible, but it must
be of same type.

Type of measuring cable : LIYY- LIYCY

Material

Metering tube : 1.4571

Process connections : 1.4571

Lining : PTFE

Electrodes : Hastelloy C22

Housing : Preamplifier : Cast aluminium, plastic coated


Housing : Polyurethane

Temperature/Humidity

Liquid temperature max. : 140 °C

Ambient temperature max. : 70 °C

Ambient humidity : < 75% on average, dew-formation permissible

Protection class : IP 67 according to EN 60 529

Power supply

Voltage : 24 V ± 10 % sine wave

Frequency : 50 Hz ±5% or 60 Hz ±5%

Distortion factor : max 1%


Technical data

Electronics

General

Housings : - Panel mounting or


- 19" rack

Protection class : panel housing

front : IP 65 acc. to EN 60 529


connection : IP 20 acc. to EN 60 529

: 19" rack : IP 20 acc. to EN 60529

Power supply : 18 VDC to 36 VDC

Ripple : < 1%

Power consumption : depending on number of cards

Ambient temperature max. : 50 °C

Ambient humidity max. : mean < 50%, dew-formation not permissible

Converter card UV-12

Input : Measuring voltage and reference voltage from transmitter

Measuring range : 10 m/s standard


2.5 m/s option

Output : 0 to 50 kHz proportional to velocity in the pipe


( other frequencies on request )
see documentation UV-12

Counter/Valve card LS-23

Input : Frequency from converter card UV-12


Pulses from NAMUR-card QB- 181 ( option )

Output : valve driver for control of solenoid valves


max. voltage : 36 VDC
max. current : 0.5 A

Master card DR-11

Inputs from QB-xxx : 24 VDC ± 15%


High-level : > 10 VDC
Low-level : < 5VDC
Input resistance : 2.4 kOhm

Outputs to QB-xxx : 18 VDC to 36 VDC


Output current max. : 10 mA
Error Limits

Reference conditions according DIN 19200 and VDI / VDE 2641

Fluid : water ( free of gas )


Liquid temperature : + 25 °C ± 2 K

Ambient temperature : + 22 °C ± 2 K

Warm-up time : 30 min.

Installation acc. : up-stream section > 10 DN


reference conditions : down-stream section > 5 DN

Error limits according reference conditons

Power supply for transmitter : 24 V ± 10 %


Frequency : 50 Hz ±5% and 60 Hz ±5% respectively

Power supply for electronics : 18 V to 36 V DC


Ripple : < 1%

Pulse output : ± 0.5 % of measured value plus ± 0.01% FS

: FS = 50 kHz at 10 m/s

Repeatability : ± 0.1 % of measured value plus ± 0.005 % FS

Build-up time : 50 ms ( 10 % to 90 % FS )

Temperature drift during


warm-up time = 30 min. : ±1% of measured value plus ± 0.1 % FS

Temperature influence on
Transmitter and electronics : ± 0.1 % / 10 degr. C
6. Requirements for commissioning:

a) the meter must be correctly installed

b) the pipe must be completely filled with product

c) the power supply for meters and dosing control must be switched on

d) the flow velocity must be absolutely zero:

before starting the dosing/filling machine a zero point setting must be carried out;
this is done by pressing key F7 and F2: the zero point procedure is carried out commonly for
all converter cards/meters connected to the system. Upon successful completion, the green
LED´s on the front panal of the MDS-30; MDS-49 and BGT-84 are off. If not refer to
chapter 7., fault finding !

e) the start release unit of the filling machine must be connected:

This is connected to the start input of the master card DR-11 via its terminal adapter;
a 24 VDC pulses of at least 10 ms is necessary.
To check the operation ( follow-up the dosing procedure ) the operator terminal should be in
position F6 ! If there are any problems refer to chapter 7.,fault finding.

7. Fault finding

a) zero point setting is not possible:

assumptions: pipe is completely filled with liquid,


power supply is switched on

a1) power supply of the meter via the 3 LED´s of the terminal adapter card QB-173:

24 VAC for the meter coils


Upper LED is off check if 24 VAC is present
check fuses on terminal adapter QB-173

+ 15 VDC of converter card and pre- amplifier


centre LED is off check if 24 VDC is present
fault of converter card: replace!

- 15 VDC of converter card and pre.amplifier


Lower LED is off check if 24 VDC is present
fault of converter card : replace!

a2) reference voltage:

assumption: 24 VAC is present ( upper LED is on )


prüfen: measure the reference voltage between the
brown wire and the shield ( terminal adapter
QB-173 ); it should be 2,5 to 3,5 VAC!

if this voltage cannot be received:

check reference cable ( brown wire and shield )


on cable break or short-circuit

if reference cable is o.k.:

replace meter ( meter defect )


a3) set of automatic zero point :

for checking the function of the zero point setting circuitry ( part of
the converter card UV-12 ) the white wire must be removed from
the terminal. Then install a short connection between both
terminals from the white wire and the shield on QB-173.
Now press key F7 of the operator terminal and after F2
( for " yes" ).

zero point setting successfull ? ( "Yes" means : green LED is off)


if "no" : replace converter card
if "yes" : replace meter

a4) oscillation zero point:

check:

- the whole system ( piping, meter, valve) must completely be filled with
product and free of gas
- are the valves closed?
- the conductivity of the product must be > 1 µS/cm
- the flow velocity must be > 0.25 m/sec
v (m/sec) = ( Q x 1.273,2 ) : DN2
Q (l/sec) = ( v x DN2 ) : 1.273,2

b) alternating/oscillating batch quantities:

b1) alternating/oscillating actual quantities( volume/weight of the


receptacle):

check:

- does the liquid level of the tank decrease filling by filling by more than
5% of its previous value? The excess volume may differ from filling to
filling.

Refer to chapter 4, section a)!

- if the dosing time is < 0.5 sec the closing time of the valve influences
the accuracy of the batch volume. The closing time of the valve must
not excess 10% of the dosing time.

Refer to chapter 4., section c)c1)!

b2) altern./oscill. counter quantities ( see operator terminal key F6):

- if the real/true quantities ( appearing in the display ) differ by not more


than +/- 1ml compared with the set quantities, but the contents of the
receptacles do ( i.e. show bigger differences compared to the set
quantities ) then the valve outlet is dripping ( varying from filling to
filling ) When the valve closes the product must cease lowing instantly!

Check design/construction of the valve outlet !


c) Function of LED on Master card DR-11 and Counter/Valve card LS-23

These cards have 2 LED in front

red CPU

This LED is ON, if the CPU in the system stand still. In this case, the
system is automatically restarted.

Check following, If this is not sucessfull :

a) EPROM installed ?
b) CPU or EPROM correct installed in the socket ?
c) Quartz for CPU --> OK

If a) to c) --> OK, change card

yellow no function for dosíng application

This LED is used for showing information for our serviceman. Several
software version used this LED for indication e.g. the startinput.
UV-12 / 1
UV-12 / 1
UV-12 / 2
UV-12 / 2

MDS 30

MDS 84
UV-12 / 3
UV-12 / 3
UV-12 / 4
UV-12 / 4
UV-12 / 5
UV-12 / 5
UV-12 / 6
UV-12 / 6
LS-23/1
LS-23/1

DR-11
UV-12 / 7
Electronics MDS-30 / 49 / 84

UV-12 / 8

UV-12 / 9

UV-12 /10

UV-12 /11

UV-12 /12

LS-23/2

Installation of the units in the housing


UV-12 / 1
UV-12 /13
UV-12 / 2
UV-12 /14
UV-12 / 3
UV-12 /15
UV-12 / 4
UV-12 /16
MDS 49

UV-12 / 5
UV-12 /17
UV-12 / 6
UV-12 /18
LS-23/1
LS-23/3
master card

UV-12 / 7
converter card

DR-11
UV-12 / 8
Max. built-in units:

counter/valve card

UV-12 / 9
1
1
6

UV-12 / 10

UV-12 / 11

UV-12 / 12

LS-23/2
1
2
12
- MDS-30 for max. 6 channels

- MDS-84 for max. 18 channels


- MDS-49 for max. 12 channels

DR-11
1
3
18
MDS-30 MDS-49 MDS-84
The elektronics is available in 3 different housings:
units
QB-xxx

MDS 84
MDS 30

QB-172
QB-181

QB-xxx QB-173 / 6

View on the
QB-172/3 QB-173 / 5
QB-181/3
QB-173 / 4
QB-173 / 18
QB-173 / 3
QB-173 / 17
QB-173 / 2
QB-173 / 16
QB-173 / 1
QB-173 / 15

QB-173 / 14

QB-173 / 13

QB-172/2
QB-181/2

QB-173 / 12
QB-xxx
QB-173 / 11
QB-172/2
QB-173 / 10
QB-181/2
QB-173 / 9
QB-173 / 12
QB-173 / 8
QB-173 / 11
MDS 49

QB-173 / 7
QB-173 / 10
QB-172/1

component side
QB-173 / 9
QB-181/1
QB-173 / 8
QB-173 / 6
QB-173 / 7
QB-173 / 5
QB-172/1

Installation of the terminal connector cards in the housing


QB-173 / 4
QB-181/1
QB-173 / 3
QB-173 / 6
QB-173 / 2
QB-173 / 5
QB-173 / 1
QB-173 / 4

card
QB-173 / 3

QB-173 / 2

QB-173 / 1

View on the
terminal connector
Dimension MDS- 30/49

terminal connector card


front
screw

144

35
A 240

MDS-30 MDS-49
A 192 288

Dimension MDS- 49 / 84

133 57

A
B 240

MDS-49 MDS-84
A 287 465
B 305 483

Current consumption depending of the number of units ( only 24 VDC )

1 2 3 4 5 6

MDS 30 0,2A 0,3A 0,4 0,5A 0,6A 0,7A

7 8 9 10 11 12

MDS 49 0,85A 0,95A 1,05A 1,15A 1,25A 1,35A

13 14 15 16 17 18

MDS 84 1,5A 1,6A 1,7A 1,8A 1,9A 2A


<<<<<< ATTENTION - ATTENTION - ATTENTION - ATTENTION <<<<<<

How to take action

1. before first commissioning, and

2. when replacing components.


--------------------------------------------------------------------------------------------------------------------------------------------------

1. before first commissioning

a. Activate batteries on cards DR- 11 and LS- 23:

The built- on batteries will store the set data in case of power failure.

Batteries on cards supplied from stock are


de- activated to avoid discharge during storage.

To activate the batteries the jumpers must be brought in position " ON ".
For jumper position see following drawings:

- card DR- 11: draw. No. 2- 81- 14816.4


- card LS- 23: draw. No. 2- 81- 14821.4.

b. Set (key- in) system data into the LAUER terminal:

For correct function of the dosing system the following data must be set:

F1 number of dosing lines e. g. 1

F2 size (DN) of flowmeter e. g. 10 mm

F3 batch quantity e. g. 100 ml

F5 max. permissible dosing time e. g. 1000 ms

c. When using a PLC (instead of a LAUER terminal):

All telegrams, containing the system data, must be sent to the dosing system.

d. Fill dosing line with liquid.

e. Set zero point by pressing key F7.

Now the dosing system is ready for operation!


-------------------------------------------------------------------------------------------------------------------------------- ------------------
2. when replacing components

If a card DR- 11 (or LS- 23) must be replaced by a new one, first activate the
battery on the new card by bringing the jumper in position " ON "; see above!
If the dosing system contains further cards DR- 11 (or LS- 23), which must not
be replaced, pull their battery jumpers and bring them back to position " ON ".

Replacement of cards only when power supply had been switched- off!

So, all stored system data are erased!


Key- in system data as described above.
Adjustment from the batterie jumper

Reset ( not change !!! )

OFF ON
Batterie

LS-23

OFF ON

Batterie

DR-11
Magnetic inductive flowmeter
Type MID-MDS
Dosing system

Instruction Manual

Terminal Type LAUER

Functions

Number of fillers x
Diameter of MID x
Preset for all filler x
Max. number of channels 4
Start external/ manual / automatic
max. Dosingtime
Output tolerance
2-step valve closing x
Totalizator
Dosingtime for each channel
Overflowcorrection x
K-Factor
Multiproduct
2-step dosing

Hardware necessary

QB-170 x
QB-183
4,5

144

90
128
194
207
215

panal dimension depth =48 mm panal cut-off

The key´s F1 to F8 are for setting the dosing parameters. After setting press ENTER.

When power-supply is switched on, filler batch maxtime zero/set


the main menu is showing diameter overflow actual

F1 number of fillers
F2 diameter of the meter F1 F2 F3 F4 F5 F6 F7 F8
F3 batch quantity
F4 overflow correction
F5 max. dosingtime ( no function with separat
start inputs )
F6 actual values
F7 zeropoint setting

F1 Number of Fillers
filler batch maxtime zero/set

i.e number of magnetic flowmeter diameter overflow actual

F1 F2 F3 F4 F5 F6 F7 F8

max. number of fillers = 4


number of fillers : __

Menue
only the valves at the registered fillers
are activated

back to menue with F8 F1 F2 F3 F4 F5 F6 F7 F8


F2 diameter of fillers ( mm )

i.e. dia./DN of magnetic inductive filler batch maxtime zero/set


flowmeter; this tells the counter and valve
card LS-23 which meter K-factor (stored
diameter overflow actual

in the counter-section) must be selected;


there is no pulse standardization in the
F1 F2 F3 F4 F5 F6 F7 F8
converter card UV-12

The diameter are following:


diameter of fillers : __
10,15,20,25 32,40
Menue

back to the menue with F8


F1 F2 F3 F4 F5 F6 F7 F8

F3 batch quantity
filler batch maxtime zero/set

batch quantity ..... ml: diameter overflow actual

the quantity stored here is true for all


fillers ( see F1 )
F1 F2 F3 F4 F5 F6 F7 F8

B open ..... % :
valve B opening at x %; x = 0 % to 50 %
B closed ..... % :
valve B closing at x %; batch quantity : _____ ml
B open at : __ % B closed at : __ %
x =0% --> valve B allways closed Menue

Save --> press ENTER


Cancel --> press MENUE F1 F2 F3 F4 F5 F6 F7 F8

F4 Overflow correction " yes - no " filler batch maxtime zero/set

diameter overflow actual

if " yes " : press key F2


F1 F2 F3 F4 F5 F6 F7 F8
an overflow correction is carried-out with
each dosing process

if " no " : press key f4 overflow correction : yes

yes no Menue
there is no overflow correction

F1 F2 F3 F4 F5 F6 F7 F8
after having pressed F2 or F4
press key F8 to go back to the menue
F5 max. time (max. 65 000 msec)

max. dosing time : ______ ms


filler batch maxtime zero/set

Only one softwaretimer is present. This diameter overflow actual

timer is reseted with each new start on


any startinput.
An emergency switch off for each F1 F2 F3 F4 F5 F6 F7 F8
channel is not possible.

max. dosing time : _____ ms

F1 F2 F3 F4 F5 F6 F7 F8

F6 filler ..., set ...., real ..., ... t


filler batch maxtime zero/set

diameter overflow actual

two numbers must be keyed-in


( only, if desired resp. in the case a
certain filler should dose a quantity F1 F2 F3 F4 F5 F6 F7 F8
differing from that under F3); used the
cursor:

" filler ": e.g. filler no. 2


" set " : e.g. 125 ml
filler : __ set : _______ ml

this is possible for all fillers, real : _______ ml Menue

filler by filler!

under " real " the real/true quantity F1 F2 F3 F4 F5 F6 F7 F8


measured by the meter appears in the
display (e.g. 124.96 ml)
F7 zero point ? " yes - no "

this makes possible to activate the zero filler batch maxtime zero/set
point setting circuitry of the converter diameter overflow actual Total
card UV-12 for to carry out an automatic
zero point setting
F1 F2 F3 F4 F5 F6 F7 F8

zero point ?
yes
yes no

press key F2
F1 F2 F3 F4 F5 F6 F7 F8

zero point setting in process zero point setting


zero point setting

F1 F2 F3 F4 F5 F6 F7 F8

when " zero point setting out " appears zero point setting out

in the display this procedure is finished; quit

acknowledge by pressing key F8

F1 F2 F3 F4 F5 F6 F7 F8

zero point ?

yes no
no

press key F8
F1 F2 F3 F4 F5 F6 F7 F8

back to the menue filler batch maxtime zero/set

diameter overflow actual

F1 F2 F3 F4 F5 F6 F7 F8
Accuracy of Dosing Systems with Magnetic Flowmeters and Electronics
Series MID- MDS
-------------------------------------------------------------------------------------------------------------------------------- ----------------------

Introduction

Talking about accuracy of dosing systems series MID- MDS (also true for the system MID- NFD) means
to talk about repeatability. The absolute accuracy, i. e. the difference between both the measured batch quantity
and e. g. the weight, is not so important for dosing applications.
All measuring (dosing) systems have inaccuracies. So, a dosing system consisting only of the magmeter
and its dosing electronics (valve and nozzle/valve outlet are not included) has an absolute accuracy of

=< +/- 0.5 % of reading

within a velocity range of 0,5 to 10 m/sec.

This absolute (in-) accuracy is a constant quantity and can be eliminated by adjusting (changing) the preset
value (batch quantity). With the new software (MDS) the calibration factor for each magmeter can be
changed individually and so the preset value (batch quantity) adjusted to an optimum.

But there is an additional uncertainty to be observed, the total repeatability R of the complete system:

R TOTAL = R 2MDS + R 2VALVE + R 2NOZZLE + R 2DENSITY

Rtotal = repeatability of the complete system


RMDS = repeatability of the magmeter and dosing electronics
Rvalve = repeatability of the dosing valve
Rnozzle = repeatability of the nozzle/valve outlet
Rdensity = repeatability of the density of the liquid

RMDS = the repeatability of the magmeter and dosing electronics is


=< 0.1 % of the batch quantity
within a velocity range of 0,5 to 10 m/sec

Rvalve = the repeatability of the dosing valve is depending on the batch time;
there is not yet any information known about the repeatability of e. g. GEMÜ valves.
According our experience with diaphragm valves: the repeatability is better than 1 %
of the valve's delay time; the delay time of GEMÜ valves is approx. 70 millisec; after
this time has gone the valve is closed.
So, it is only important to know, which quantity passes the valve during this time!
See two examples sheet 2!

Rnozzle = the repeatability of the nozzle(valve outlet) is very hard to be estimated;


in general one must be sure , that always the same quantity passes the nozzle after the
valve had been closed. No dripping is acceptable; if it is dripping, the number and the
volume of the drops should be constant and cease quickly!

Rdensity = the influence of the density of the liquid is very important, too;
it should be known as exact as possible; the liquid temperature should be kept as
constant as possible during a machine shift to eliminate this influence!
The density alteration of e. g. water is approx. 0.2 ml/degree centigrade.
Reference for determination of the meter size
-------------------------------------------------------------------------------------------------------------------------------- ----------------------

It´s possible to fill up with one meter size a wide range of dosing quantities in the same time.

The table below shows, which meter size is recommended.

It shows the dosing quantity in relationship to the velocity in the meter pipe :

DN v = 0,5 m/s v = 1 m/s v = 2,5 m/s


10 40 ml/s 80 ml/s 200 ml/s
15 88 ml/s 176 ml/s 440 ml/s
20 157 ml/s 314 ml/s 785 ml/s
25 245 ml/s 490 ml/s 1225 ml/s
32 402 ml/s 804 ml/s 2010 ml/s
40 628 ml/s 1256 ml/s 3140 ml/s

The velocity of 1 m/sec is ideal for high product care, accuracy and wear. If the velocity is higher, then the pressure
shock increase if the valve is closing.. On the other hand, If the velocity is lower, then with several products
deposits are possible..

Utilization for plastic pipes


-------------------------------------------------------------------------------------------------------------------------------- ----------------------

It´s very important to know, that the dosing accuracy and the repeatablility are depending on the oscillation of the
product in the pipe. A product oscillation is possible, if plastic pipes are installed within the product line. If the valve
is closing, then the pressure increase and the plastic pipe works like a memory. If plastic pipes are required, then
they must be metallcoated. A spiral from metal for reinforcement the plastic pipe is not adequate to guarantee the
repeatability.
The length of the plastic pipe must be as short as possible. Are the pipes are longer then 1 m, then a mechanical
support must be for prevent pipe oscillations, if pressure shocks are existing.
Magnetisch-Induktiver-Durchflußmesser Magnetic Inductive Flowmeter
Dosiersystem Typ MDS Dosing System type MDS
----------------------------------------------------------- -----------------------------------------------
Klemmenkarte QB-170 Terminal adapter card QB-170
für Masterkarte DR-11 for master card DR-11
4 getrennte Starteingänge 4 separate start inputs
CIP-Eingang CIP-input

Aufgabe Application
Die Klemmenkarte QB-170 wird für den Anschluß The terminal connector card is necessary for
der zentralen Ein-und Ausgänge benötigt. connection the central inputs and outputs.

Schnittstellen date link


Es sind zwei RS 232 Schnittstellen vorhanden : two RS 232 data link are available:

1.) TXD1, RXD1, GND1 zum Anschluß 1) TXD1, RXD1, GND1 for connection to
einer SPS oder eines PC´s PLC or PC

2) TXD2, RXD2, GND2 zum Anschluß der 2) TXD2, RXD2, GND2 for connection to
Bedienerterminal LAUER terminal type LAUER

Es ist jedoch nur der Betrieb mit einer Schnittstelle It is only possible to work with one of this serial link,
möglich, d.h. entweder SPS oder LAUER-Terminal not with both.

Eingänge 24 VDC plusaktiv / 5 mA input signal 24 VDC activplus / 5 mA

Start Kanal 1 bis 4 start canal 1 to 4


CIP CIP

siehe Impulsdiagramm Seite 2 see pulse diagram page 2

LAUER-Terminal
KL2

serielle Schnittstelle
serial data link

TxD 2 braun / brown


24 VDC
GND 2 Schirm / shield
RxD 2 weiß / white
TxD 1
GND 1
RxD 1
PC / PLC
KL1

CIP CIP
Stöext. Start Kanal 4 / start channel 4
Stöin.
Ready
Format 2 Start Kanal 3 / start channel 3
Format 1 Start Kanal 2 / start channel 2
Start 1 Start Kanal 1/ start channel 1
Dosieren / dosing

Dosierung beendet
batch end
CIP

Start 1
start 1

Start2
start 2

Start 3
start 3

Start 4
start 5

Ventil 1
valve 1

Ventil 2
valve 2

Ventil 3
valve 3

Ventil 4
valve 4

CIP

CIP

Start 1
start 1

Start2
start 2

Start 3
start 3

Start 4
start 5

Ventil 1
valve 1

Ventil 2
valve 2

Ventil 3
valve 3

Ventil 4
valve 4
Magnetisch-Induktiver-Durchflußmesser Magnetic Inductive Flowmeter
Dosiersystem Typ MDS Dosing System type MDS
----------------------------------------------------------- -----------------------------------------------
Klemmenkarte QB-172 Terminal adapter card QB-172
für Zähler/Ventilkarte LS-23 for counter/ valve card LS-23

Aufgabe Application

Die Klemmenkarte QB-172 wird für den Anschluß The terminal connector card is necessary for
der Hilfsenergie und der Ventile benötigt. connection the power supplies and the valves.
Für 6 Messkanäle wird je eine Klemmenkarte One terminal connector card is necessary for 6
benötigt. measuring channels.

Hilfsenergie: Power supply:


Bei zwei und mehr Klemmenkarten sollten die Are more then one terminal connector card installed,
Anschlüsse immer von der Karte zur Spannungs- connection to the power supply should be
versorgung verlegt werden ( siehe Seite 2 ). star-shaped ( see page 2).

Ventilausgänge: Valve outputs:

Ausgang A :ist bei der Dosierung immer Output A : allways open during batch
geöffnet
Ausgang B :kann bei zweistufigem Ventil Output B : in addition to A if
zugeschaltet werden 2-stage-valves are used

Die Ventilausgänge sind plusschaltende Ausgänge. The valve outputs switches + 24VDC
max. Spannung : 36 VDC max. voltage : 36 VDC
max. Strom : 0,5 A max. current : 0,5 A

Der Ausgang ist kurzschlußsicher und gegen The outputs are short-circuit proof and over voltage
Überspannung beim Schalten von induktiven protected.
Lasten geschützt.

Hilfsenergie für die Elektronik


+24VDC + 24 VDC
-24 VDC Power supply for electronic
Masse / ground
24 VAC Hilfsenergie für Aufnehmer
24 VAC , 50/60 Hz
24 VAC Power supply for transmitter

V 1A V1A
Magnetventil solenoid valve
V 1B V1B
V 2A V2A
V 2B V2B V1A bis V6B
V1A to V6B

V 3A V3A
V 3B V3B
V 4A V4A

V 4B V4B
V 5A V5A Membranventil
V 5B V5B Masse 24 VDC
diaphragmvalve
V 6A V6A ground 24 VDC

V 6B V6B
Magnetisch-Induktiver-Durchflußmesser Magnetic Inductive Flowmeter
Dosiersystem Typ MDS Dosing System type MDS
----------------------------------------------------------- -----------------------------------------------
Klemmenkarte QB-172 Terminal adapter card QB-172
für Zähler/Ventilkarte LS-23 for counter/ valve card LS-23

Anschluß der Hilfsenergie 24 VAC und 24 VDC Power supply 24 VAC and 24 VDC

Die Hilfsenergie sollte sternförmig von jeder the connection between the terminal connector card
Klemmenkarte zur Stromversorgung angeschaltet and the power supply should be star-shaped.
werden.

2 4 V AC

24 VDC
Magnetisch-Induktiver-Durchflußmesser Magnetic Inductive Flowmeter
Dosiersystem Typ MDS Dosing System type MDS
----------------------------------------------------------- -----------------------------------------------
Klemmenkarte QB-173 Terminal adapter card QB-173
für Eingangskarte UV-12 for converter card UV-12
Anschluß an Aufnehmer Typ MDS Connection to transmitter type MDS

Aufgabe Application

Die Klemmenkarte QB-173 wird zum Anschluß des The terminal connector card is necessary for the
Messkabels benötigt. measuring cable connection. This cable connected
Dieses Kabel stellt die Verbindung des Aufnehmers the transmitter and the converter card.
zur Eingangskarte her.
Das Messkabel ist ein handelsübliches Kabel The trade mark of this cable is : LIYY-LIYCY
DIN Bezeichnung : LIYY- LIYCY
Mit diesem Kabel werden folgende Signale On this cable following signals are transmitted:
übertragen:

- Versorgungsspannung 24 VAC für die - power supply 24 VAC for the coils in the
Aufnehmerspulen transmitter
- +/- 15 VDC für die Versorgung des - +/- 15 VDC for the preamplifier
Vorverstärkers - reference voltage
- Referenzspannung - measuring voltage
- Meßspannung

Weiterhin befinden sich auf der Klemmenkarte: Furthermore are installed on the card:

- 2 Sicherungen 24 VAC ( 400 mA ) - 2 fuses 24 VAC ( 400 mA )


für die Aufnehmerspulen for the transmitter coils
- 3 LED zur Anzeige von - 3 LED for indication of
- +/- 15 VDC - +/- 15 VDC
- 24 VAC - 24 VAC

rot / red
blau / blue

Meßkabel zum Aufnehmer


braun / brown Measuring cable to transmitter
gelb / yellow
grün / green
Schirm / shield
weiß / white

Sicherungen 400 mA für Aufnehmer

fuses 400 mA for transmitter

LED
24 VAC für Aufnehmer / 24 VAC for transmitter
+ 15 VDC für Vorverstärker / + 15 VDC for preamplifier
- 15 VDC für Vorverstärker / - 15 VDC for preamplifier